Download

New Product
DIN Track Push-in Terminal Blocks
XW5T
Push-in Plus Terminal Blocks to
Downsize Control Panels and Save
Work
• Push-in Plus terminal blocks are more compact than traditional
screw terminal blocks.
No loosening means maintenance-free application.
• Slim models available down to a width of 3.5 mm to help
downsize control panels.
• Light insertion force and strong holding strength to achieve
both less wiring work and high reliability.
• ‘Hand-free’ structure that holds an inserted screwdriver to
achieve easier wiring work in comparison with attaching crimp
terminals.
For the most recent information on models that have been
certified for safety standards, refer to your OMRON website.
Refer to Safety Precautions on page 8.
Model Number Legend
Feed Through Terminal Blocks
XW5T - P@-@-@@
XW5G - P@-@-@
(1) (2) (3)(4)
(1) Maximum Applicable
Stranded Wire
1.5: 1.5mm2
2.5: 2.5mm2
4.0: 4.0mm2
Grounding Terminal Blocks
(1) (2) (3)
(2) Wiring
1.1: 1:1
1.2: 1:2
(3) Number of Tiers
1: 1 tier
2: 2 tiers
(4) Color
Blank: Dark gray
BL: Blue
2.2: 2:2
1
XW5T
Ordering Information
Product
type
Applicable wire sizes
Applicable wire sizes
with ferrules attached
Color
Wiring
Tiers
Model
1:1
1:2
Dark gray
2
2
0.08 mm to 1.5 mm
AWG 28 to AWG 14
2
1:1
0.14 mm to 1.0 mm
AWG 26 to AWG 18
2
0.14 mm to 4.0 mm
AWG 26 to AWG 12
2
2
2
2
0.14 mm to 2.5 mm
AWG 26 to AWG 14
2
2
0.2 mm to 4.0 mm
AWG 24 to AWG 12
0.2 mm to 6.0 mm
AWG 24 to AWG 10
XW5T-P1.5-1.2-1
XW5T-P1.5-2.2-1
2 tiers
XW5T-P1.5-1.1-2
1:1
1:2
Blue
2
1 tier
2:2
2
Feed Through
Terminal
Blocks
XW5T-P1.5-1.1-1
XW5T-P1.5-1.1-1BL
1 tier
XW5T-P1.5-1.2-1BL
2:2
XW5T-P1.5-2.2-1BL
1:1
2 tiers
XW5T-P1.5-1.1-2BL
Dark gray
1:1
1 tier
XW5T-P2.5-1.1-1
Blue
1:1
1 tier
XW5T-P2.5-1.1-1BL
Dark gray
1:1
1 tier
XW5T-P4.0-1.1-1
Blue
1:1
1 tier
XW5T-P4.0-1.1-1BL
1:1
2
Grounding
Terminal
Blocks
2
2
1:2
2
XW5G-P1.5-1.1-1
1 tier
XW5G-P1.5-1.2-1
0.08 mm to 1.5 mm
AWG 28 to AWG 14
0.14 mm to 1.0 mm
AWG 26 to AWG 18
1:1
2 tiers
XW5G-P1.5-1.1-2
0.14 mm2 to 4.0 mm2
AWG26 to AWG 12
0.14 mm2 to 2.5 mm2
AWG 26 to AWG 14
1:1
1 tier
XW5G-P2.5-1.1-1
0.2 mm2 to 6.0 mm2
AWG 24 to AWG 10
0.12 mm2 to 4.0 mm2
AWG 24 to AWG 12
1:1
1 tier
XW5G-P4.0-1.1-1
2:2
Green/yellow
XW5G-P1.5-2.2-1
Accessories
Short Bars
Labels
For XW5T-P1.5-@ or XW5G-P1.5-@
No. of poles
Colors
2
3
4
5
Model
XW5S-P1.5-2@@
Red (RD)
Blue(BL)
Yellow (YL)
10
XW5S-P1.5-3@@
XW5S-P1.5-4@@
4
5
Red (RD)
Blue(BL)
Yellow (YL)
10
Model
4
5
10
XW5Z-P2.5LB2
XW5S-P2.5-3@@
XW5S-P2.5-4@@
XW5S-P2.5-5@@
XW5Z-P4.0LB1
XW5T-P4.0-@
XW5Z-P4.0LB2
XW5S-P2.5-10@@
Colors
Model
XW5S-P4.0-2@@
2
3
XW5Z-P2.5LB1
XW5T-P2.5-@
For XW5T-P4.0-@ or XW5G-P4.0-@
No. of poles
XW5Z-P1.5LB2
XW5S-P2.5-2@@
2
3
XW5T-P1.5-@
XW5S-P1.5-10@@
Colors
Red (RD)
Blue(BL)
Yellow (YL)
Model
XW5Z-P1.5LB1
XW5S-P1.5-5@@
For XW5T-P2.5-@ or XW5G-P2.5-@
No. of poles
Applicable Terminal
Blocks
XW5S-P4.0-3@@
XW5S-P4.0-4@@
XW5S-P4.0-5@@
XW5S-P4.0-10@@
Description
For Top
1 sheet
(102 pieces)
For Side
1 sheet
(108 pieces)
For Top
1 sheet
(72 pieces)
For Side
1 sheet
(72 pieces)
For Top
1 sheet
(60 pieces)
For Side
1 sheet
(60 pieces)
End Cover
Applicable Terminal Blocks
Model
[email protected]
XW5E-P1.5-1.1-1
[email protected]
XW5E-P1.5-1.1-2
[email protected]
XW5E-P1.5-1.2-1
[email protected]
XW5E-P1.5-2.2-1
[email protected]
XW5E-P2.5-1.1-1
[email protected]
XW5E-P4.0-1.1-1
End Brackets/Separator Plates
2
Name
Width (mm)
End Brackets
6
XW5Z-EP6
Model
Separator Plates
12
XW5Z-EP12
XW5T
Ratings and Performance
Feed Through Terminal Blocks
1 tier, 1:1
1 tier, 1:1
1 tier, 1:1
Appearance and internal
wiring
Applicable wire sizes
0.08 to 1.5 mm2
(Stranded wires: 0.08 to 1.5 mm2,
Solid wire: 0.14 to 1.5 mm2)
AWG28 to AWG14
0.14 to 4.0 mm2
(Stranded wires: 0.14 to 2.5 mm2,
Solid wire: 0.14 to 4.0 mm2)
AWG26 to AWG12
0.2 to 6.0 mm2
(Stranded wires: 0.2 to 4.0 mm2,
Solid wire: 0.2 to 6.0 mm2)
AWG24 to AWG10
Model
XW5T-P1.5-1.1-1(BL)
XW5T-P2.5-1.1-1(BL)
XW5T-P4.0-1.1-1(BL)
Dimensions
3.5×45×30.5
5.2×48.8×35.25
6.2×56.1×35.25
IEC rated voltage
500 V
800 V
IEC rated current
17.5 A/1.5 mm2 (SOL), 13.5 A/1.0 mm2 (STR)
24 A/2.5 mm2 (SOL), 17.5 A/1.5 mm2 (STR) 32 A/4.0 mm2 (SOL), 24 A/2.5 mm2 (STR)
Usage Group (UG)
B, C
D
B, C
UL rated voltage
300 V
51-150 V 151-300 V 301-600 V 600 V
UL rated current
15 A (SOL) 15 A (SOL)
10 A
10 A (STR) 10 A (STR)
Dielectric strength
1,890 VAC for 1 min
(leakage current: 1 mA max.)
5A
20 A/AWG12 (SOL), 15 A/AWG14 (STR)
30 A/AWG10 (SOL), 20 A/AWG12 (STR)
2,000 VAC for 1 min (leakage current: 1 mA max.)
Operating temperature range −40 to 55°C (with no condensation or icing)
Operating humidity range
5% to 95%
Compliant standards
cULus (UL 1059) and IEC 60947-7-1
Insertion durability
50 times
Vibration resistance
10 to 150 Hz Acceleration 50m/s2 for 80 min each in X, Y, and Z directions
Shock resistance
500 m/s2 11 ms, each in 6 directions 5 times
End Cover
XW5E-P1.5-1.1-1
Special tool
XW4Z-00B
Applicable nameplates
XW5Z-P1.5LB@ or commercially available
nameplate with 9.5 mm width and 0.5 mm
thickness
Applicable Short Bars
XW5S-P1.5-@ (@: Poles = 2, 3, 4, 5 or 10) XW5S-P2.5-@ (@: Poles = 2, 3, 4, 5 or 10) XW5S-P4.0-@ (@: Poles = 2, 3, 4, 5 or 10)
Weight
Approx. 3.3 g
XW5E-P2.5-1.1-1
XW5E-P4.0-1.1-1
XW5Z-P2.5LB@ or commercially available
nameplate with 9.5 mm width and 0.5 mm
thickness
XW5Z-P4.0LB@ or commercially available
nameplate with 9.5 mm width and 0.5 mm
thickness
Approx. 6.3 g
2 tiers, 1:1
Approx. 8.2 g
1 tier, 1:2
1 tier, 2:2
Appearance and internal
wiring
Applicable wire sizes
0.08 to 1.5 mm2
(Stranded wires: 0.08 to 1.5 mm2,
Solid wire: 0.14 to 1.5 mm2)
AWG28 to AWG14
Model
XW5T-P1.5-1.1-2(BL)
XW5T-P1.5-1.2-1(BL)
XW5T-P1.5-2.2-1(BL)
Dimensions
3.5×65.7×41.1
3.5×54.1×30.5
3.5×63.2×30.5
IEC rated voltage
500 V
IEC rated current
17.5 A/1.5 mm2 (SOL), 13.5 A/1.0 mm2 (STR)
Usage Group (UG)
B, C
D
UL rated voltage
300 V
51-150 V
151-300 V
301-600 V
UL rated current
15 A (SOL), 10 A (STR)
15 A (SOL), 10 A (STR)
10 A
5A
Dielectric strength
1,890 VAC for 1 min (leakage current: 1 mA max.)
Operating temperature range −40 to 55°C (with no condensation or icing)
Operating humidity range
5% to 95%
Compliant standards
cULus (UL 1059) and IEC 60947-7-1
Insertion durability
50 times
Vibration resistance
10 to 150 Hz Acceleration 50m/s2 for 80 min each in X, Y, and Z directions
Shock resistance
500 m/s2 11 ms, each in 6 directions 5 times
End Cover
XW5E-P1.5-1.1-2
Special tool
XW4Z-00B
Applicable nameplates
XW5Z-P1.5LB2
Applicable Short Bars
XW5S-P1.5-@ (@: Poles = 2, 3, 4, 5 or 10)
Weight
Approx. 6.6 g
XW5E-P1.5-1.2-1
XW5E-P1.5-2.2-1
XW5Z-P1.5LB@ or commercially available nameplate with 9.5 mm width and 0.5 mm thickness
Approx. 4.1 g
Approx. 4.8 g
3
XW5T
Grounding Terminal Blocks
1 tier, 1:1
1 tier, 1:1
1 tier, 1:1
Appearance and internal
wiring
Applicable wire sizes
0.08 to 1.5 mm2
(Stranded wires: 0.08 to 1.5 mm2,
Solid wire: 0.14 to 1.5 mm2)
AWG28 to AWG14
0.14 to 4.0 mm2
(Stranded wires: 0.14 to 2.5 mm2,
Solid wire: 0.14 to 4.0 mm2)
AWG26 to AWG12
0.2 to 6.0 mm2
(Stranded wires: 0.2 to 4.0 mm2,
Solid wire: 0.2 to 6.0 mm2)
AWG24 to AWG10
Model
XW5G-P1.5-1.1-1
XW5G-P2.5-1.1-1
XW5G-P4.0-1.1-1
Dimensions
3.5×45×30.5
5.2×48.8×35.25
6.2×56.1×35.25
IEC rated voltage
500 V
800 V
Operating temperature range −40 to 55°C (with no condensation or icing)
Operating humidity range
5% to 95%
Compliant standards
cULus (UL 1059) and IEC 60947-7-2
Insertion durability
50 times
Vibration resistance
10 to 150 Hz Acceleration 50m/s2 for 80 min each in X, Y, and Z directions
Shock resistance
500 m/s2 11 ms, each in 6 directions 5 times
End Cover
XW5E-P1.5-1.1-1
Special tool
XW4Z-00B
Applicable nameplates
XW5Z-P1.5LB@ or commercially available
nameplate with 9.5 mm width and 0.5 mm
thickness
Applicable Short Bars
XW5S-P1.5-@ (@: Poles = 2, 3, 4, 5 or 10) XW5S-P2.5-@ (@: Poles = 2, 3, 4, 5 or 10) XW5S-P4.0-@ (@: Poles = 2, 3, 4, 5 or 10)
Weight
Approx. 4.7 g
XW5E-P2.5-1.1-1
XW5E-P4.0-1.1-1
XW5Z-P2.5LB@ or commercially available
nameplate with 9.5 mm width and 0.5 mm
thickness
XW5Z-P4.0LB@ or commercially available
nameplate with 9.5 mm width and 0.5 mm
thickness
Approx. 9.9 g
2 tiers, 1:1
Approx. 11.7 g
1 tier, 1:2
1 tier, 2:2
Appearance and internal
wiring
Applicable wire sizes
0.08 to 1.5 mm2
(Stranded wires: 0.08 to 1.5 mm2,
Solid wire: 0.14 to 1.5 mm2)
AWG28 to AWG14
Model
XW5G-P1.5-1.1-2
XW5G-P1.5-1.2-1
XW5G-P1.5-2.2-1
Dimensions
3.5×65.7×41.1
3.5×54.1×30.5
3.5×63.2×30.5
IEC rated voltage
500 V
Operating temperature range −40 to 55°C (with no condensation or icing)
Operating humidity range
5% to 95%
Compliant standards
cULus (UL 1059) and IEC 60947-7-2
Insertion durability
50 times
Vibration resistance
10 to 150 Hz Acceleration 50m/s2 for 80 min each in X, Y, and Z directions
Shock resistance
500 m/s2 11 ms, each in 6 directions 5 times
End Cover
XW5E-P1.5-1.1-2
Special tool
XW4Z-00B
Applicable nameplates
XW5Z-P1.5LB2
Applicable Short Bars
XW5S-P1.5-@ (@: Poles = 2, 3, 4, 5 or 10)
Weight
Approx. 8.2 g
XW5E-P1.5-1.2-1
XW5Z-P1.5LB@ or commercially available nameplate with 9.5 mm width and 0.5 mm
thickness
Approx. 5.5 g
Short Bars
Model
4
XW5S-P1.5-@
XW5S-P2.5-@
Rated voltage
500 V
800 V
Rated current
17.5 A
24 A
XW5E-P1.5-2.2-1
XW5S-P4.0-@
32 A
Approx. 6.3 g
XW5T
Dimensions
(Unit: mm)
DIN Track Terminal Blocks
XW5T-P1.5-1.1-1(BL)/XW5G-P1.5-1.1-1
XW5T-P2.5-1.1-1(BL)/XW5G-P2.5-1.1-1
3.5
5.2
48.8
45
24.5
29.25
30.5
35.25
XW5T-P1.5-1.2-1(BL)/XW5G-P1.5-1.2-1
XW5T-P4.0-1.1-1(BL)/XW5G-P4.0-1.1-1
3.5
56.1
6.2
54.1
24.5
29.25
35.25
30.5
XW5T-P1.5-2.2-1(BL)/XW5G-P1.5-2.2-1
3.5
63.2
24.5
30.5
XW5T-P1.5-1.1-2(BL)/XW5G-P1.5-1.1-2
65.7
3.5
33.7
35.1
24.5
41.1
30.5
5
XW5T
Short Bars
XW5S-P1.5-@
3.5×(No. of poles-1)+2.3
3
Model
XW5S-P1.5-2@
18.2
P (mm)
3.5
XW5S-P1.5-3@
7
XW5S-P1.5-4@
10.5
XW5S-P1.5-5@
14
XW5S-P1.5-10@
31.5
1.6
3.5
XW5S-P2.5-@
5.2×(No. of poles-1)+3.7
3
Model
23
P (mm)
XW5S-P2.5-2@
5.2
XW5S-P2.5-3@
10.4
XW5S-P2.5-4@
15.6
XW5S-P2.5-5@
20.8
XW5S-P2.5-10@
46.8
1.6
5.2
XW5S-P4.0-@
6.2×(No. of poles-1)+4.4
3
Model
23
1.6
6.2
6
P (mm)
XW5S-P4.0-2@
6.2
XW5S-P4.0-3@
12.4
XW5S-P4.0-4@
18.6
XW5S-P4.0-5@
24.8
XW5S-P4.0-10@
55.8
XW5T
End Cover
XW5E-P1.5-1.1-1
XW5E-P2.5-1.1-1
2.2
45
2.2
48.8
24.5
29.4
XW5E-P1.5-1.2-1
XW5E-P4.0-1.1-1
2.2
2.2
56.1
54.1
24.5
29.4
XW5E-P1.5-2.2-1
2.2
63.2
24.5
XW5E-P1.5-1.1-2
2.2
65.4
35.1
End Brackets/Separator Plates
XW5Z-EP12 (Separator Plates)
XW5Z-EP6 (End Brackets)
6
55
12
56
33.5
40.2
63
7
XW5T
Safety Precautions
Warning Indications
Precautions
for Safe Use
Precautions
for Correct
Use
Precautions for Correct Use
Supplementary comments on what to do or
avoid doing, to use the product safely.
Supplementary comments on what to do or
avoid doing, to prevent failure to operate,
malfunction, or undesirable effects on
product performance.
Precautions for Safe Use
• Do not wire anything to the release holes.
• Do not tilt or twist a flat-blade screwdriver while it is inserted into a
release hole on the terminal block. The terminal block may be
damaged.
• Insert a flat-blade screwdriver into the release holes at an angle.
The terminal block may be damaged if you insert the screwdriver
straight in.
• Do not allow the flat-blade screwdriver to fall out while it is inserted
into a release hole.
• Do not bend a wire past its natural bending radius or pull on it with
excessive force.
Doing so may cause the wire disconnection.
• Do not insert more than one wire into each terminal insertion hole.
• Do not install the Terminal Block upside down when mounting
multiple Terminal Blocks.
Doing so may cause short circuits with the adjacent Terminal
Block.
• To prevent wiring materials from smoking or ignition, use the wiring
materials given in the following table.
Stripping length
Recommended
Wire
With Ferrules
1. Precautions for Correct Use
• Do not drop the Terminal Block.
Terminal Block functionality may be inhibited.
• Always attach End Cover. Not doing so may cause electrical
shock.
• When you wire the Terminal Block, do not subject it or the wires to
stress. Secure the wires so that they do not resonate with
vibrations from the facilities in installation conditions.
• Always turn OFF the power supply before wiring. Electrical shock
may occur.
2. Connecting Wires to the Push-In Plus Terminal
Block
Part Names of the Terminal Block
Release hole
Terminal (Insertion) hole
Connecting Wires with Ferrules and Solid Wires
Insert the solid wire or ferrule straight into the terminal block until the
end strikes the terminal block.
If a wire is difficult to connect because it is too thin, use a flat-blade
screwdriver in the same way as when connecting stranded wire.
Without Ferrules
XW5T-P1.5-@-@@
0.08 to 1.5 mm2/
AWG 28 to 14
8 mm
8 mm
XW5T-P2.5-@-@@
0.25 to 4 mm2/
AWG 24 to 12
10 mm
10 mm
XW5T-P4.0-@-@@
0.25 to 6 mm2/
AWG 24 to 10
12 mm
12 mm
Ferrule or solid wire
Terminal (Insertion) hole
Note: Please use Ferrules with UL certification (R/C).
Connecting Stranded Wires
Use the following procedure to connect the wires to the terminal block.
1. Hold a flat-blade screwdriver at an angle and insert it into the
release hole. The angle should be between 10° and 15°.
If the flat-blade screwdriver is inserted correctly, you will feel the
spring in the release hole respond.
2. With the flat-blade screwdriver still inserted into the release hole,
insert the wire into the terminal hole until it strikes the terminal
block.
3. Remove the flat-blade screwdriver from the release hole.
10 to 15°
Flat-blade screwdriver
3
8
Wire
2
1
XW5T
Checking Connections
• After the insertion, pull gently on the wire to make sure that it will
not come off and the wire is securely fastened to the terminal block.
• To prevent short circuits, insert the stripped part of a stranded or
solid wire or the conductor part of a ferrule until it is hidden inside
the terminal insertion hole. (See the following diagram.)
3. Removing Wires from the Push-In Plus
Terminal Block
Use the following procedure to remove wires from the terminal block.
The same method is used to remove stranded wires, solid wires, and
ferrules.
1. Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
2. With the flat-blade screwdriver still inserted into the release hole,
remove the wire from the terminal insertion hole.
3. Remove the flat-blade screwdriver from the release hole.
10 to 15°
Flat-blade screwdriver
3
Wire
2
1
4. Recommended Ferrules and Crimp Tools
Recommended ferrules
XW5T-P1.5-@-@@
Applicable
wire
Recommended ferrules
Ferrule
Conductor
Manufactured
length
Manufactured Manufactured
by Phoenix
(mm2) (AWG)
(mm)
by Weidmuller
by Wago
Contact
0.14
26
8
AI 0.14-8
H0.14/12
---
0.25
24
8
AI 0.25-8
H0.25/12
FE-0.25-8N-YE
0.34
22
8
AI 0.34-8
H0.34/12
FE-0.34-8N-TQ
0.50
20
8
AI 0.5-8
H0.5/14
FE-0.5-8N-WH
0.75
18
8
AI 0.75-8
H0.75/14
FE-0.75-8N-GY
1.00
18
8
AI 1-8
H1.0/14
FE-1.0-8N-RD
CRIMPFOX6
CRIMPFOX6-F
CRIMPFOX10S
PZ6 roto
Variocrimp4
Recommended crimp tool
XW5T-P2.5-@-@@
Applicable
wire
Recommended ferrules
Ferrule
Conductor
Manufactured
length
Manufactured Manufactured
(mm2) (AWG)
by Phoenix
(mm)
by Weidmuller
by Wago
Contact
0.25
24
10
AI 0.25-10 YE
---
---
0.34
22
10
AI 0.34-10 TQ
---
---
H0.5/16
FE-0.5-10N-WH
0.50
20
10
AI 0.5-10 WH
0.75
18
10
AI 0.75-10 GY H0.75/16
FE-0.75-10N-GY
1.00
18
10
AI 1-10 RD
H1.0/16
FE-1.0-10N-RD
1.50
16
10
AI 1.5-10 BK
H1.5/16
FE-1.5-10N-BK
2.50
14
10
AI 2.5-10 BU
H2.5/16DS
FE-2.5-10N-BU
CRIMPFOX6
CRIMPFOX6-F
CRIMPFOX10S
PZ6 roto
Variocrimp4
Recommended crimp tool
XW5T-P4.0-@-@@
Applicable
wire
Recommended ferrules
Ferrule
Conductor
Manufactured
length
Manufactured Manufactured
(mm2) (AWG)
by Phoenix
(mm)
by Weidmuller
by Wago
Contact
0.25
24
12
AI 0.25-12 BU
---
---
0.34
22
12
AI 0.34-12 TQ
---
---
0.50
20
12
AI 0.5-12 WH
---
FE-0.5-12N-WH
0.75
18
12
AI 0.75-12 GY H0.75/18
FE-0.75-12N-GY
1.00
18
12
AI 1-12 RD
H1.0/18
FE-1.0-12N-RD
1.50
16
12
AI 1.5-12 BK
H1.5/18D
FE-1.5-12N-BK
2.50
14
12
AI 2.5-12 BU
H2.5/19D
FE-2.5-12N-BU
4.00
12
12
AI 4-12 GY
H4.0/20D
FE-4.0-12N-GY
CRIMPFOX6
CRIMPFOX6-F
CRIMPFOX10S
PZ6 roto
Variocrimp4
Recommended crimp tool
Note: 1. Make sure that the outer diameter of the wire is smaller than
the inner diameter of the insulation sleeve of the
recommended ferrule.
2. Make sure that the ferrule processing dimensions conform
to the following figure.
8 mm
2.1 mm max.
2.7 mm max.
9
XW5T
Recommended Flat-blade Screwdriver
5. Mounting to DIN Track/Removing from DIN Track
Use a flat-blade screwdriver to connect and remove wires.
Use the following flat-blade screwdriver.
The following table shows manufacturers and models as of 2015/Dec.
Mounting Method
Side
To mount a Terminal Block to a DIN Track, press it against the DIN
Track as shown in the following figure.
Front
2.5 mm dia.
0.4 mm
2.5 mm
Model
XW4Z-00B
Manufacturer
Omron
ESD0.40✕2.5
Wera
SZF 0.4✕2.5
Phoenix Contact
0.4✕2.5✕75 302
Wiha
AEF.2.5✕75
Facom
210-719
Wago
SDI 0.4✕2.5✕75
Weidmuller
Removal Method
To remove a Terminal Block from the DIN Track, catch the tip of a
screwdriver in the hook, operate the screwdriver so that the tip moves
in direction (1), and then remove the Terminal Block in direction (2).
However, so not apply excessive force to the Terminal Block. Doing
so may damage it.
(2)
(1)
6. Storage
Store the Terminal Block within the following temperature range.
-40 to 85°C (with no condensation or icing)
10
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Kyoto, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
2895 Greenspoint Parkway, Suite 200
Hoffman Estates, IL 60169 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2016 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
CSM_1_1_0316
Cat. No. G124-E1-01
0316(0316)