New Product DIN Track Terminal Blocks with Screw Terminals XW5T Global-standard DIN Terminal Blocks for Control Panels • Wires held with screws. • Compatible with a wide range of wire sizes from 0.14 to 185 mm2. • Terminal Blocks with Fuses and Disconnect Terminal Blocks are available. Refer to Safety Precautions on page 14. Refer to your OMRON website for the most recent information on models that are certified for standards. Model Number Legend Feed Through Terminal Blocks Grounding Terminal Blocks XW5T - S@-@-@@ XW5G - S@-@-@ (1) (2) (3) (4) (1) (2) (3) (1) Nominal Cross Section 2.5: 2.5mm2 4.0: 4.0mm2 6.0: 6.0mm2 10: 10mm2 16: 16mm2 35: 35mm2 70: 70mm2 150: 150mm2 (2) Wiring 1.1:1:1 1.2:1:2 (3) Number of Tiers 1: 1 tier 2: 2 tiers (4) Color Blank: Dark gray BL: Blue V: Black (Vertical Connection) 2.2:2:2 1 XW5T Ordering Information Product type Applicable wire sizes 2 2 0.14mm - 4mm AWG26-AWG12 Applicable wire sizes with ferrules attached 2 2 0.5mm - 2.5mm AWG20-AWG14 Color Wiring Dark gray 1:1 Blue 1:1 Dark gray 1:1 Dark gray 1:1 Number of tiers XW5T-S2.5-1.1-1 100 100 XW5T-S2.5-1.1-2 100 XW5T-S2.5-1.1-2V 100 XW5T-S4.0-1.1-1 100 XW5T-S4.0-1.2-1 100 2:2 XW5T-S4.0-2.2-1 100 1:1 XW5T-S4.0-1.1-2 100 XW5T-S4.0-1.1-2V 100 XW5T-S4.0-1.1-1BL 100 XW5T-S4.0-1.2-1BL 100 XW5T-S4.0-2.2-1BL 100 1:2 2 2 0.14mm - 6mm AWG26-AWG10 2 2 0.5mm - 4mm AWG20-AWG12 1:1 2 tiers 1 tier 2 tiers 1:1 Blue Feed Through Terminal Blocks 1:2 1 tier 2:2 Dark gray 1:1 1 tier XW5T-S6.0-1.1-1 100 Blue 1:1 1 tier XW5T-S6.0-1.1-1BL 100 Dark gray 1:1 1 tier XW5T-S10-1.1-1 50 Blue 1:1 1 tier XW5T-S10-1.1-1BL 50 0.2mm2 - 10mm2 AWG24-AWG8 0.5mm2 - 6mm2 AWG20-AWG10 0.5mm2 - 16mm2 AWG20-AWG6 0.5mm2 - 10mm2 AWG20-AWG8 4mm2 - 25mm2 AWG12-AWG4 4mm2 - 16mm2 AWG12-AWG6 Dark gray 1:1 1 tier XW5T-S16-1.1-1 50 Blue 1:1 1 tier XW5T-S16-1.1-1BL 50 10mm2 - 50mm2 AWG10-AWG1/0 10mm2 - 35mm2 AWG10-AWG2 Dark gray 1:1 1 tier XW5T-S35-1.1-1 20 Blue 1:1 1 tier XW5T-S35-1.1-1BL 20 10mm2 - 95mm2 AWG6-AWG2/0 10mm2 - 70mm2 AWG6-AWG2/0 Dark gray 1:1 1 tier XW5T-S70-1.1-1 20 Blue 1:1 1 tier XW5T-S70-1.1-1BL 20 35mm2 - 185mm2 AWG2/0-350kcmil 35mm2 - 150mm2 AWG2/0-300kcmil Dark gray 1:1 1 tier XW5T-S150-1.1-1 10 Blue 1:1 1 tier XW5T-S150-1.1-1BL 10 0.14mm2 - 4mm2 AWG26-AWG12 0.5mm2 - 2.5mm2 AWG20-AWG14 1:1 1 tier XW5G-S2.5-1.1-1 100 XW5G-S4.0-1.1-1 100 XW5G-S4.0-1.2-1 100 XW5G-S4.0-2.2-1 100 1:1 2 Grounding Terminal Blocks Disconnect Terminal Blocks 2 2 2 0.5mm - 4mm AWG20-AWG12 0.2mm2 - 10mm2 AWG24-AWG8 0.5mm2 - 6mm2 AWG20-AWG10 2 0.5mm - 16mm AWG20-AWG6 2 1:2 2 0.14mm - 6mm AWG26-AWG10 2 0.5mm - 10mm AWG20-AWG8 1 tier 2:2 Green/yellow 2 1:1 2 tiers XW5G-S4.0-1.1-2 100 1:1 1 tier XW5G-S6.0-1.1-1 100 1:1 1 tier XW5G-S10-1.1-1 50 4mm - 25mm AWG12-AWG4 4mm - 16mm AWG12-AWG6 1:1 1 tier XW5G-S16-1.1-1 50 10mm2 - 50mm2 AWG10-AWG1/0 10mm2 - 35mm2 AWG24-AWG2 1:1 1 tier XW5G-S35-1.1-1 20 10mm2 - 95mm2 AWG6-AWG2/0 10mm2 - 70mm2 AWG6-AWG2/0 1:1 1 tier XW5G-S70-1.1-1 20 XW5T-S4.0-FU5 50 0.5mm2 - 4mm2 AWG20-AWG12 0.14mm2 - 2.5mm2 AWG26-AWG14 XW5T-S4.0-FU6 50 XW5T-S4.0-KD 100 2 Terminal Blocks with Fuses Minimum order XW5T-S2.5-1.1-1BL 1 tier 1:1 Dark gray Model 2 2 2 Dark gray 1:1 1 tier XW5T Accessories Short Bars Separator Plates For XW5 -S2.5- No. of poles Color 2 Model Minimum order XW5S-S2.5-2 10 XW5S-S2.5-3 10 XW5S-S2.5-4 10 5 XW5S-S2.5-5 10 10 XW5S-S2.5-10 20 3 Yellow (YL) 4 For XW5 -S4.0- No. of poles Color 2 Model XW5S-S4.0-2 3 Labels Applicable Terminal Blocks Marking Model Minimum order 25 XW5Z-S2.5LB-1-10 25 11-20 XW5Z-S2.5LB-11-20 25 21-30 XW5Z-S2.5LB-21-30 25 31-40 XW5Z-S2.5LB-31-40 25 41-50 XW5Z-S2.5LB-41-50 25 51-60 XW5Z-S2.5LB-51-60 25 61-70 XW5Z-S2.5LB-61-70 25 71-80 XW5Z-S2.5LB-71-80 25 Minimum order 81-90 XW5Z-S2.5LB-81-90 25 25 10 5 XW5S-S4.0-5 10 10 XW5S-S4.0-10 20 XW5 -S2.5- For XW5 -S6.0- Model 10 XW5Z-S2.5LB 10 Color XW5Z-S2.5PT Minimum order 1-10 XW5S-S4.0-4 No. of poles Model None 10 Yellow (YL) XW5 -S2.5-1.1- XW5 -S4.0-1.1- XW5 -S6.0-1.1- XW5 -S10-1.1- Minimum order XW5S-S4.0-3 4 Applicable Terminal Blocks 91-100 XW5Z-S2.5LB-91-100 2 XW5S-S6.0-2 10 1-100 XW5Z-S2.5LB-1-100 1 3 XW5S-S6.0-3 10 None XW5Z-S4.0LB 25 XW5S-S6.0-4 10 1-10 XW5Z-S4.0LB-1-10 25 XW5S-S6.0-5 10 11-20 XW5Z-S4.0LB-11-20 25 21-30 XW5Z-S4.0LB-21-30 25 31-40 XW5Z-S4.0LB-31-40 25 41-50 XW5Z-S4.0LB-41-50 25 51-60 XW5Z-S4.0LB-51-60 25 61-70 XW5Z-S4.0LB-61-70 25 71-80 XW5Z-S4.0LB-71-80 25 81-90 XW5Z-S4.0LB-81-90 25 91-100 XW5Z-S4.0LB-91-100 25 1-100 XW5Z-S4.0LB-1-100 1 None XW5Z-S6.0LB 25 1-10 XW5Z-S6.0LB-1-10 25 Minimum order 11-20 XW5Z-S6.0LB-11-20 25 21-30 XW5Z-S6.0LB-21-30 25 Yellow (YL) 4 5 For XW5 -S10- No. of poles 2 Color Yellow (YL) Model XW5S-S10-2 Minimum order XW5 -S4.0- 10 For XW5 -S16- No. of poles 2 Color Yellow (YL) Model XW5S-S16-2 Minimum order 10 Cross Connector with Screw For XW5 -S2.5-1.1-2 No. of poles Color Model 2 XW5S-S2.5-2N 10 31-40 XW5Z-S6.0LB-31-40 25 3 XW5S-S2.5-3N 10 41-50 XW5Z-S6.0LB-41-50 25 XW5S-S2.5-4N 10 51-60 XW5Z-S6.0LB-51-60 25 XW5S-S2.5-5N 10 61-70 XW5Z-S6.0LB-61-70 25 10 71-80 XW5Z-S6.0LB-71-80 25 81-90 XW5Z-S6.0LB-81-90 25 91-100 XW5Z-S6.0LB-91-100 25 1-100 XW5Z-S6.0LB-1-100 1 Yellow (YL) 4 5 10 XW5S-S2.5-10N End Covers Applicable Terminal Blocks Model Minimum order XW5 -S2.5-1.1- XW5 -S4.0-1.1- XW5 -S6.0-1.1- XW5 -S10-1.1- XW5E-S2.5 10 XW5T-S16-1.1- XW5E-S16 10 XW5T-S4.0-KD XW5 -S4.0-1.2-1 XW5E-S4.0-1.2-1 10 XW5 -S4.0-2.2-1 XW5E-S4.0-2.2-1 10 XW5 -S4.0-1.1-2 XW5E-S4.0-1.1-2 10 XW5T-S2.5-1.1-2 XW5E-S2.5N 10 XW5 -S6.0- 3 XW5T Ratings and Specifications Feed Through Terminal Blocks 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 Applicable wire sizes 0.14 to 4 mm2 (Stranded wires: 0.14 to 4 mm2, Solid wire: 0.14 to 4 mm2) 0.14 to 6.0 mm2 (Stranded wires: 0.14 to 6.0 mm2, Solid wire: 0.14 to 6.0 mm2) 0.2 to 10 mm2 (Stranded wires: 0.2 to 10 mm2, Solid wire: 0.2 to 10 mm2) 0.5 to 16 mm2 (Stranded wires: 0.5 to 16 mm2, Solid wire: 0.5 to 16 mm2) Model XW5T-S2.5-1.1-1(BL) XW5T-S4.0-1.1-1(BL) XW5T-S6.0-1.1-1(BL) XW5T-S10-1.1-1(BL) Dimensions (mm) 5×48.2×56 6×48.2×56 8×48.2×56 10×48.2×56.2 IEC rated voltage 1,000 V IEC rated current 24 A 32 A 41 A 57 A UL rated voltage 600 V UL rated current 20 A 30 A 50 A 65 A Rated impulse voltage 8 kV Operating temperature range −40 to 55°C (with no icing or condensation) Operating humidity range 5% to 95% Appearance and Internal Wiring Compliant standards UL, CSA IEC60947-7-1 End Covers XW5E-S2.5 Applicable label XW5Z-S2.5LB XW5Z-S4.0LB XW5Z-S6.0LB Applicable Short Bars XW5S-S2.5- ( : Poles = 2, 3, 4, 5, or 10) XW5S-S4.0- ( : Poles = 2, 3, 4, 5, or 10) XW5S-S6.0- ( : Poles = 2, 3, 4, or 5) XW5S-S10- ( : Poles = 2) Weight Approx. 7 g Approx. 9 g Approx. 14 g Approx. 16 g --- 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 Applicable wire sizes 1.5 to 25 mm2 (Stranded wires: 16 to 25 mm2, Solid wire: 1.5 to 16 mm2) 10 to 35 mm2 (Stranded wires: 10 to 35 mm2, Solid wire: 10 mm2) 10 to 70 mm2 35 to 150 mm2 (Stranded wires: 16 to 95 mm2) (Stranded wires: 35 to 150 mm2) Model XW5T-S16-1.1-1(BL) XW5T-S35-1.1-1(BL) XW5T-S70-1.1-1(BL) XW5T-S150-1.1-1(BL) Dimensions (mm) 12×58.5×62 16×63×75.1 24×75.2×88.7 28×96×106.1 IEC rated voltage 1,000 V 800 V IEC rated current 76 A 124 A 179 A 309 A UL rated voltage 600 V UL rated current 85 A 150 A 175 A 335 A Rated impulse voltage 8 kV Operating temperature range −40 to 55°C (with no icing or condensation) Operating humidity range 5% to 95% Appearance and Internal Wiring Compliant standards 4 1,000 V UL, CSA IEC60947-7-1 End Covers XW5E-S16 Applicable Short Bars XW5S-S16- ( : Poles = 2) Weight Approx. 36 g ----Approx. 73 g Approx. 172 g Approx. 268 g XW5T Feed Through Terminal Blocks 2 tiers, 1:1 2 tiers, 1:1 1 tier, 1:2 Appearance and Internal Wiring Applicable wire sizes 0.5 to 2.5 mm2 (Stranded wires: 0.5 to 2.5 mm2, Solid wire: 0.5 to 4 mm2) 0.5 to 2.5 mm2 (Stranded wires: 0.5 to 2.5 mm2, Solid wire: 0.5 to 4 mm2) 0.14 to 6.0 mm2 (Stranded wires: 0.14 to 6 mm2, Solid wire: 0.14 to 6 mm2) Model XW5T-S2.5-1.1-2 XW5T-S2.5-1.1-2V XW5T-S4.0-1.2-1(BL) Dimensions (mm) 5×65.8×71.4 IEC rated voltage 500 V IEC rated current 24 A 32 A UL rated voltage 600 V 300 V UL rated current 20 A 30 A Rated impulse voltage 8 kV 6 kV Operating temperature range −40 to 55°C (with no icing or condensation) Operating humidity range 5% to 95% Compliant standards 6×58×56 UL, CSA IEC60947-7-1 End Covers XW5E-S2.5N XW5E-S4.0-1.2-1 Applicable label XW5Z-2.5LB XW5Z-4.0LB Applicable Short Bars XW5S-S2.5- N ( : Poles = 2, 3, 4, 5, or 10) XW5S-S4- ( : Poles = 2, 3, 4, 5, or 10) Weight Approx. 12 g Approx. 13 g Approx. 14 g 1 tier, 2:2 2 tiers, 1:1 2 tiers, 1:1 Appearance and Internal Wiring Applicable wire sizes 0.14 to 6.0 mm2 (Stranded wires: 0.14 to 6 mm2, Solid wire: 0.14 to 6 mm2) Model XW5T-S4.0-2.2-1(BL) XW5T-S4.0-1.1-2 Dimensions (mm) 6×69×58 6×73×75 IEC rated voltage 500 V 800 V IEC rated current 32 A UL rated voltage 300 V UL rated current 30 A Rated impulse voltage 6 kV Operating temperature range −40 to 55°C (with no icing or condensation) Operating humidity range 5% to 95% Compliant standards 0.14 to 6.0 mm2 (Stranded wires: 0.14 to 6 mm2, Solid wire: 0.14 to 6 mm2) XW5T-S4.0-1.1-2V 8 kV UL, CSA IEC60947-7-1 End Covers XW5E-S4.0-2.2-1 Applicable label XW5Z-4.0LB Applicable Short Bars XW5S-S4- ( : Poles = 2, 3, 4, 5, or 10) Weight Approx. 16 g XW5E-S4.0-1.1-2 Approx. 18 g Approx. 19 g 5 XW5T Grounding Terminal Blocks 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 Applicable wire sizes 0.14 to 4 mm2 (Stranded wires: 0.14 to 4 mm2, Solid wire: 0.14 to 4 mm2) 0.14 to 6.0 mm2 (Stranded wires: 0.14 to 6.0 mm2, Solid wire: 0.14 to 6.0 mm2) 0.2 to 10 mm2 (Stranded wires: 0.2 to 10 mm2, Solid wire: 0.2 to 10 mm2) 0.5 to 16 mm2 (Stranded wires: 0.5 to 16 mm2, Solid wire: 0.5 to 16 mm2) Model XW5G-S2.5-1.1-1 XW5G-S4.0-1.1-1 XW5G-S6.0-1.1-1 XW5G-S10-1.1-1 Dimensions (mm) 5×48.2×56 6×48.2×56 8×48.2×56 10×48.2×56.2 IEC rated voltage 600 V UL rated voltage 600 V Rated impulse voltage 8 kV Operating temperature range −40 to 55°C (with no icing or condensation) Operating humidity range 5% to 95% Appearance and Internal Wiring Compliant standards 1,000 V UL IEC60947-7-2 End Covers XW5E-S2.5 Applicable label XW5Z-S2.5LB XW5Z-S4.0LB XW5Z-S6.0LB Weight Approx. 10 g Approx. 12 g Approx. 20 g 1 tier, 1:1 1 tier, 1:1 1 tier, 1:1 Applicable wire sizes 1.5 to 25 mm2 (Stranded wires: 16 to 25 mm2, Solid wire: 1.5 to 16 mm2) 10 to 35 mm2 (Stranded wires: 10 to 35 mm2, Solid wire: 10 to 50 mm2) 10 to 70 mm2 (Stranded wires: 10 to 70 mm2, Solid wire: 16 to 95 mm2) Model XW5G-S16-1.1-1 XW5G-S35-1.1-1 XW5G-S70-1.1-1 Dimensions (mm) 12×58.5×62 16×63×75.1 24×75.2×88.7 IEC rated voltage 1,000 V UL rated voltage 600 V Rated impulse voltage 8 kV Operating temperature range −40 to 55°C (with no icing or condensation) Operating humidity range 5% to 95% Appearance and Internal Wiring Compliant standards 6 UL IEC60947-7-2 End Covers XW5E-S16 Weight Approx. 47 g --Approx. 119 g Approx. 233 g --Approx. 22 g XW5T Grounding Terminal Blocks 1 tier, 1:2 1 tier, 2:2 2 tiers, 1:1 Appearance and Internal Wiring Applicable wire sizes 0.14 to 6.0mm2 (Stranded wires: 0.14 to 6 mm2, Solid wire: 0.14 to 6 mm2) 0.14 to 6.0 mm2 (Stranded wires: 0.14 to 6 mm2, Solid wire: 0.14 to 6 mm2) 0.14 to 6.0 mm2 (Stranded wires: 0.14 to 6 mm2, Solid wire: 0.14 to 6 mm2) Model XW5G-S4.0-1.2-1 XW5G-S4.0-2.2-1 XW5G-S4.0-1.1-2 Dimensions (mm) 6×58×56 6×69×58 IEC rated voltage 500 V UL rated voltage 300 V Rated impulse voltage 6 kV Operating temperature range −40 to 55°C (with no icing or condensation) Operating humidity range 5% to 95% UL Compliant standards IEC60947-7-2 End Covers XW5E-S4.0-1.2-1 Applicable label XW5Z-4.0LB Weight Approx. 15 g XW5E-S4.0-2.2-1 XW5E-S4.0-1.1-2 Approx. 19 g Approx. 22 g Terminal Blocks with Fuses Model 6×73×75 800 V XW5T-S4.0-FU5 Disconnect Terminal Blocks XW5T-S4.0-FU6 Model Appearance and Internal Wiring XW5T-S4.0-KD Appearance and Internal Wiring Applicable wire sizes 0.5 to 6.0mm2 (Stranded wires: 0.5 to 4.0 mm2, Solid wire: 0.5 to 6.0 mm2) Rated voltage 800 V Rated current 6.3 A UL rated voltage 600 V UL rated current 6.3 A Rated impulse voltage Applicable wire sizes 0.14 to 6.0mm2 (Stranded wires: 0.14 to 6.0 mm2, Solid wire: 0.14 to 6.0 mm2) Rated voltage 500 V Rated current 20 A UL rated voltage 300 V UL rated current 16 A 8 kV Rated impulse voltage 6 kV Operating temperature range −40 to 55°C Operating temperature range −40 to 55°C Operating humidity range 5% to 95% Operating humidity range 5% to 95% Compliant standards UL, CSA Compliant standards IEC60947-7-1, UL, CSA End Covers XW5E-S4.0-1.2-1 Applicable Short Bars XW5S-S4.0-@ Applicable label XW5Z-S4.0LB@ 10 A 10 A End Covers --- Applicable label --- Short Bar Model XW5S-S2.5- IEC rated voltage 600 V IEC rated current 20 A UL rated voltage 600 V UL rated current 20 A Compliant standards XW5S-S4.0- XW5S-S6.0- XW5S-S10- XW5S-S16- 1,000 V 30 A 50 A 57 A 76 A 30 A 50 A 65 A 85 A UL IEC60947-7-1 7 XW5T Dimensions (Unit: mm) XW5 - 2.5-1.1-1 XW5 -S4.0-1.1-1 5 6 48.2 48.2 44 44 41 56 41 56 46.8 48.6 46.8 48.6 47.8 47.8 42.2 Mounting rail EN 60715-35x7.5 42.2 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x15 XW5 -S6.0-1.1-1 XW5 -S10-1.1-1 8 10 48.2 48.2 44 44 41 56 46.8 48.6 48.6 56.2 56.2 48.6 47.8 47.8 42.2 Mounting rail EN 60715-35x7.5 42.2 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x15 XW5 -S16-1.1-1 Mounting rail EN 60715-35x7.5 XW5 -S35-1.1-1 12 16 58.5 63 57.5 47 62 52.8 54.5 53.7 75.1 69 67.6 27.9 29.3 35.4 47.25 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x7.5 13.85 G-rail EN 60715-G32 8 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 XW5T XW5 -S70-1.1-1 XW5 -S150-1.1-1 24 28 75.2 96 91.7 88.7 82.7 81.2 16.4 106.1 100.1 29.6 98.6 31.1 37.1 19.95 G-rail EN 60715-G32 25.8 Mounting rail EN 60715-35x15 27.3 33.3 G-rail EN 60715-G32 Mouting rail EN 60715-35x7.5 28.25 Mounting rail EN 60715-35x15 XW5 -S2.5-1.1-2 XW5 -S4.0-1.2-1 6 5 65.8 58 56 34 43 56 48.8 48 63.9 47.8 68.4 71.4 42.2 G-rail EN 60715-G32 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x15 XW5 -S4.0-2.2-1 XW5 -S4.0-1.1-2 6 6 69 73 68 72 37.7 58 50 75 67 52.4 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 54.5 Mounting rail EN 60715-35x7.5 Mounting rail EN 60715-35x15 9 XW5T XW5T-S4.0-FU5 XW5T-S4.0-FU6 10 8 77.2 77.2 54.5 54.5 59 59 62 56.6 Mounting rail EN 60715-35x15 Mounting rail EN 60715-35x7.5 G-rail EN 60715-G 32 XW5T-S4.0-KD 6 58 56 58 50 Mounting rail EN 60715-35x7.5 42.2 Mounting rail EN 60715-35x15 10 56.6 Mounting rail EN 60715-35x15 62 Mounting rail EN 60715-35x7.5 G-rail EN 60715-G 32 XW5T Short Bars XW5S-S2.5- For XW5 -S2.5- Model (2.1) L (14) (23.9) (5) (1.65) l XW5S-S4.0- I (mm) L (mm) XW5S-S2.5-2 5 10 XW5S-S2.5-3 10 15 XW5S-S2.5-4 15 20 XW5S-S2.5-5 20 25 XW5S-S2.5-10 45 50 For XW5 -S4.0- 2.4 L 14 23.9 6 1.75 l XW5S-S6.0- L (mm) 6 12 XW5S-S4.0-3 12 18 XW5S-S4.0-4 18 24 XW5S-S4.0-5 24 30 XW5S-S4.0-10 54 60 Model 9 29.6 1.6 l I (mm) For XW5 -S6.0- 3 L Model XW5S-S4.0-2 I (mm) L (mm) XW5S-S6.0-2 8.2 14.7 XW5S-S6.0-3 16.4 22.9 XW5S-S6.0-4 24.6 31.1 XW5S-S6.0-5 32.8 39.3 XW5S-S16-2 XW5S-S10-2 5.4 4 20.5 17.8 18.5 15.2 35 35.8 2.4 10.2 12.2 3.6 Cross Connector with Screw XW5S-S2.5- N For XW5 -S2.5-1.1-2 5 L 9.1 0.8 5 l M2.5 Model I (mm) L (mm) XW5S-S2.5-2N 5 8.9 XW5S-S2.5-3N 10 13.9 XW5S-S2.5-4N 15 18.9 XW5S-S2.5-5N 20 23.9 XW5S-S2.5-10N 45 48.9 11 XW5T End Covers XW5E-S2.5 XW5E-S16 44 57.5 40.6 46.6 47 XW5E-S4.0-1.2-1 XW5E-S4.0-2.2-1 57.4 67.8 55.9 42 42.6 42.7 40.7 XW5E-S4.0-1.1-2 40.6 XW5E-S2.5N 33.8 72 37.7 53.2 62.5 59.5 35.4 32.1 Separator Plates XW5Z-S2.5PT 50.5 49 52.7 12 46.1 33.7 XW5T Label XW5Z-S2.5 9×5=45 4.8 5 8.3 XW5Z-S4.0 59.5 9×6=54 5.75 6 8.3 XW5Z-S6.0 79.5 9×8=72 7.75 8 8.3 13 XW5T Safety Precautions Be sure to read the precautions for all models in the website at the following URL: http://www.ia.omron.com/. Signal Word Definitions Precautions for Safe Use Precautions for Correct Use Supplementary comments on what to do or avoid doing, to use the product safely. Supplementary comments on what to do or avoid doing, to prevent failure to operate, malfunction, or undesirable effects on product performance. 2. Connecting Wires to the Terminal Block Wiring • Double-check all wiring before turning ON the power supply. • After wiring, route the cable so that force is not applied directly to the connections. Wires for Terminal Blocks Precautions for Safe Use • Do not bend a wire past its natural bending radius or pull on it with • Do not damage the cores when stripping the insulation from them. • Always twist stranded wires together before connecting them. • Do not presolder wires. It may not be possible to connect them or remove them. excessive force. Screw Tightening Torque and Applicable Wires Doing so may cause the wire disconnection. When you connect wires to a Terminal Block, use the applicable wires and tightening torque given in the following table. • Do not insert more than one wire into each terminal insertion hole. • Before you start wiring, make sure that the Terminal Block is securely attached and mounted to a DIN Track. If the Terminal Block is not stable, it may fall and possibly injure a worker. • Do not install the Terminal Block upside down when mounting multiple Terminal Blocks. Doing so may cause short circuits with the adjacent Terminal Block. Precautions for Correct Use 1. Precautions for Correct Use • Do not drop the Terminal Block. Terminal Block functionality may be inhibited. • Always attach End Cover. Not doing so may cause electrical shock. • When you wire the Terminal Block, do not subject it or the wires to stress. Secure the wires so that they do not resonate with vibrations from the facilities in installation conditions. • Always turn OFF the power supply before wiring. Electrical shock may occur. Model Wiring method Tightening torque [N·m] (Use a flatblade screwdriver.) Applicable wire sizes Applicable wire sizes with ferrules attached [email protected] M2.5 0.4 AWG26-AWG12 AWG20-AWG14 [email protected] M3 0.5 AWG26-AWG10 AWG20-AWG12 [email protected] M4 1.2 AWG24-AWG8 AWG20-AWG10 XW5@-S10 M4 1.2 AWG20-AWG6 AWG20-AWG8 XW5@-S16 M5 2 AWG12-AWG4 AWG12-AWG6 XW5@-S35 M6 2.5 AWG10-AWG1/0 AWG10-AWG2 XW5@-S70 M8 3.5 AWG6-AWG2/0 AWG6-AWG2/0 XW5@-S150 M10 4 AWG2/0-350kcmil AWG2/0-300kcmil Wire Stripping Lengths If you connect wires directly to the terminals, use the following stripping lengths. Model Stripping length [mm] [email protected] 9 [email protected] 9 [email protected] 11 XW5@-S10 13 XW5@-S16 15 XW5@-S35 18 XW5@-S70 24 XW5@-S150 30 3. Mounting to and Removing from DIN Track Removal Procedure Mounting Procedure (2) Press. (1) Hook. 1.Hook the Unit on the DIN Track. 2. Press the Unit onto the DIN Track to secure it. 14 1. Insert a flat-blade screwdriver into the DIN Track lock. 2. Move the screwdriver like a lever to free the lock. Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company Authorized Distributor: Kyoto, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, 2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC 2895 Greenspoint Parkway, Suite 200 Hoffman Estates, IL 60169 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2016 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_1_1_0316 Cat. No. G125-E1-01 0316 (0316)