© Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 ■ Overview ■ Application The following MAG 8000 versions are available as stand-alone water meters: • MAG 8000 (7ME6810) for abstraction and distribution network • MAG 8000 CT (7ME6820) for revenue and bulk metering • MAG 8000 (7ME6880) for irrigation ■ Design MAG 8000 is designed to minimize power consumption. The product program consists of • Basic and advanced version • Sensor sizes from DN 25 to 1200 (1" to 48") • Compact and remote installation in IP68/NEMA 6P enclosure and factory-mounted cable • SIMATIC PDM and Flow Tool PC configuration softwares 3 MAG 8000 is a comprehensive meter which intelligent information and high performance measurement as well as the easy to install concept take cost of ownership and customer service to a new level for water meter. ■ Benefits Easy to install • Compact or remote solution with factory mounted cable and customer setting from factory • IP68/NEMA 6P enclosure. Sensor can be buried • Flexible power supply - internal or external battery pack or mains power supply with battery back-up possibilities • Superior measurement • Down to 0.2 % maximum uncertainty • OIML R 49 type approval • PTB K7.2 • FM Fire Service Approval • Bi-directional measurement Long lasting performance/Low cost of Ownership • Verification according to Directive 2014/32/EU of the European Parliament and Council of 26 February, 2014 on measuring instruments, Annex VI Thermal Energy Meters (MI-004) • No moving parts means less wear and tear • Up to 6 to 10 years maintenance-free operation in typical revenue application • Robust construction built for the application Intelligent information, easy to access • Advanced information on site • Data logger • Advanced statistics and diagnostics • Add-on communication modules 3/116 Siemens FI 01 · 2016 Modbus/Encoder module © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 MAG 8000 GSM/GPRS Wireless Communication Module The MAG 8000 GSM/GPRS wireless communication module provides the latest mobile technology using a Quad Band (850/900/1800/1900 MHz) module. The GSM/GPRS module logs data from the MAG 8000 memory and from the two analog inputs (one 4 to 20 mA not powered by the module and one 5 V ratiometric powered by the module) and storage in the internal memory and later transmit it into a system or PC via email or SMS. GSM/GPRS communication module An additional synchronization function secures the initial collection time of the data independent of the sample rate used (minimum collection time: 1 per minute). The package of information retrieved via the csv file includes: • Time stamp • Flow rate • Tot 1 • Tot 2 • Tot 3 • Analog 1 (mA) • Analog 2 (V) • Battery lifetime • Alarm list (as decimal format) The GPRS technology makes it possible to send a higher amount of data via email. The data is secured using a POP 3 server configuration avoiding encryptions that require additional software. The configuration of the module is performed via SMS commands that allow you to define the users, email accounts, transmission settings, collection, etc. PC-IrDA connection The GSM/GPRS module is a compact built-in solution which can be installed in the existing MAG 8000 with SW version 3.02 and higher. The battery lifetime will depend on signal strength and especially on the number of transmissions. Therefore we recommend an optimal setting of transmission once a day (see page 3/121). The module also includes the same power management algorithm that secures a very good calculation of the remaining battery lifetime. The OPC server specifically designed for the MAG 8000 GSM/GPRS module is offered free of charge. With this valueadded package, the opportunity for measurement data collection and further processing/analyzing for system integration and automation is offered. Siemens FI 01 · 2016 3/117 3 © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 ■ Function MAG 8000 is a microprocessor-based water meter with graphical display and key for optimum customer operation and information on site. The transmitter drives the magnetic field in the sensor, evaluates the flow signal from the sensor and calculates the volume passing through. It delivers the required information via the integrated pulse output or communication interfaces as part of a system solution. Its intelligent functionality, information and diagnostics ensure optimum meter performance and information to optimize water supply and billing. 3 MAG 8000 can be ordered as a Basic or an Advanced version. Features / Version MAG 8000 Basic/ MAG 8000 Advanced MAG 8000 Irrigation Measuring frequency in 1/15, 1/30 or 1/60 Hz from 6.25 to 1/60 Hz battery power mode depending of sensor (Manually selected)1) size Output MAG 8000 2 FW/RV/Al/CA (max. 2 FW/RV/Al/CA (max. 50 Hz pulse rate) 100 Hz pulse rate) Communication Add-on Add-on Data logger Yes Yes Insulation test No Yes Leakage detection No Yes Meter utilization No Yes Statistics No Yes Tariff No Yes Settle date (Revenue) No Yes 1) Excitation frequency settings with mains power supply, see technical specifications for each version Some information is accessible via the display whereas all information is accessible via the IrDA communication interface with the PDM software. Data and parameters are registered in a EEPROM. They can all be read, but changing the information demands a software password or a hardware key attached to the printed circuit board. 3/118 Siemens FI 01 · 2016 The SIMATIC PDM tool gives the possibility of testing and verifying the flowmeter on site and creating a printed ”Qualification Certificate” with all specific data that define the quality status of the measurement. The Qualification Certificate consists of two pages with information about the actual status of the sensor: Part 1 provides general settings, sensor and battery info, totalizer values and pulse output settings. Part 2 provides detailed information about electronic and sensor functionality and a main parameter list for evaluating the functionality of the MAG 8000 water meter. SIMATIC PDM Details about the SIMATIC PDM tool can be found in chapter "Communication and Software" (see page 8/9). © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 ■ Technical specifications Transmitter Installation Mains power supply Compact (integral) Remote with factory-mounted cable 5, 10, 20 or 30 m (16.4, 32.8, 65.6 or 98.4 ft) Enclosure Stainl. steel top housing (AISI 316) and coated brass bottom. Remote wall mount bracket in stainless steel (AISI 304). Cable entries 2 x M20 (one gland for one cable of size 6 … 8 mm (0.02 ... 0.026 ft) is included in the standard delivery) Display Display with 8 digits for main information. Index, menu and status symbols for dedicated information Resolution Totalized information can be displayed with 1, 2 or 3 decimals or automatic adjustment (default) Flow unit Europe US Australia Volume: m3 x 100, l x 100, G x 100, G x 1000, MG, CF x 100, CF x 1000, AF, Al, kl, BBL42 Flow: m3/min, m3/d, l/s, l/min, GPS, GPH, GPD, MGD, CFS, CFM, CFH, BBL42/s, BBL42/min, BBL42/h, BBL42/d Digital output 2 passive outputs (MOS), individual galvanically isolated Maximum load ± 35 V DC, 50 mA short circuit protected Programmable as pulse volume – forward – reverse – forward/net – reverse/net Programmable as pulse volume (like output A), alarm Max. pulse rate of 50 Hz (only Basic version) and 100 Hz (only Advanced version), pulse width of 5, 10, 50, 100, 500 ms Output B function Output Communication Add-on modules Power supply Internal battery pack External battery pack 3 Volume in m3 and flow rate in m3/h Volume in Gallon and flow rate in GPM Volume in Ml and flow rate as Ml/d Optional display units Output A function Cable • 12 ... 24 V AC/DC (10 … 32 V) 2 VA • 115 ... 230 V AC (85 … 264 V) 2 VA Both mains power supply systems are upgradable for battery backup via internal D-Cell (3.6 V 16.5 Ah) or external battery pack. 3 m (9.8 ft) for external connection to mains supply (without cable plug) IrDA: Standard integrated infrared communication interface with Modbus RTU protocol • RS 232 serial interface with Modbus RTU (Rx/Tx/GND), point to point with max. 15 m cable • RS 485 serial interface with Modbus RTU (+/-/GND), multidrop with up to 32 devices with max. 1000 m cable • Encoder interface module (for Itron 200WP) "Sensus protocol" • GSM/GPRS module with or without analog input cable Auto detection of power source with display symbol for operation power. 1 D-Cell 3.6 V/16.5 Ah 2 D-Cell 3.6 V/33 Ah 4 D-Cell 3.6 V/66 Ah Siemens FI 01 · 2016 3/119 © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 Features Application identification Tag number up to 15 characters Time and date Real time clock Totalizer MAG 8000 3 3 totalizer: Configurable to Forward, Reverse and Bidirectional netflow 1 totalizer (following totalizer 1 setting) resetable via display key Insulation test (only Advanced version) Test of signal immunity against disturbance and bad installation. Test interval is selectable and measurement is interrupted during the test period of 4 min. Leakage detection (only Advanced version) Monitoring the lowest flow or volume during selected time window within 24 hours. Leakage is detected over a selectable period where monitored value exceed the possible leakage level. Min and max values are stored with date registration. Last store value visible on the display. Meter Utilization (only Advanced version) 6 registers for monitoring total time the meter has operated in different flow intervals. Registered intervals are free selectable as % of Qn (Q3) Tariff (only Advanced version) 6 tariff registers count the volume delivered within the selected tariff windows, based on time of day or flow rates or a combination. Tariff can also be used for consumption profile where consumption is related to different time intervals or flow rates. Tariff values visible on the display. Settling date (only Advanced version) On a predefined date the totalizer 1 index value is stored. Old values are stored to show the latest two totalized 1 index values. Settling values visible on the display. Statistic (only Advanced version) Min. flow rate with time and date registration Max. flow rate with time and date registration Min. daily consumption with date registration Max. daily consumption with date registration Latest 7 days total and daily consumption Actual month consumption Latest month consumption PC Configuration Software PDM • Meter configuration – online and offline mode • Own parameter settings • Parameter documentation • Print and export of data and parameters PDM 6.0 Service Pack 2 – Basic and Online version Measurement Low flow cut-off • 7ME6810 0.05 % of Qmax (adjustable) • 7ME6820 0.25 % of Q3 • 7ME6880 1 % of Qmax (adjustable) Empty pipe detection Symbolised in display Data logger Logging of 26 records: selectable as daily, weekly or monthly logging Alarm Active alarm is indicated on the display Data protection All data stored in an EEPROM. Totalizers 1 and 2 are backed up every 10 min, statistic every hour and power consumption and temperature measurement every 4 hour. Password protection of all parameters and hardware protection of calibration and revenue parameters. Battery power management Optimal battery information on remaining capacity. Calculated capacity includes all consuming elements and available battery capacity is adjusted related to change in ambient temperature. Numbers of power-ups Date and time registered for first and last time power alarm. Diagnostic Continuous self test including Alarm statistics and logging for fault analyzing 3/120 Siemens FI 01 · 2016 Coil current to drive the magnetic field Signal input circuit Data calculation, handling and storing Electrode impedance to check actual media contact Flow simulation to check pulse and communication signal chain for correct scaling Number of sensor measurements (excitations) Transmitter temperature (battery capacity calculation) Low impedance alarm for change in media Flow alarm when defined high flow exceeds Verification mode for fast measure performance check © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 MAG 8000 water meter uncertainty To ensure continuous accurate measurement, flowmeters must be calibrated. The calibration is conducted at Siemens flow facilities with traceable instruments referring directly to the physical unit of measurement according to the International System of Units (SI). Therefore, the calibration certificate ensures recognition of the test results worldwide, including the US (NIST traceability). Siemens offers accredited calibrations assured to ISO 17025 in the flow range from 0.0001 m3/h to 10 000 m3/h. Siemens Flow Instruments accredited laboratories are recognized by ILAC MRA (International Laboratory Accreditation Corporation - Mutual Recognition Arrangement) ensuring international traceability and recognition of the test results worldwide. Grounding The sensor body must be grounded using grounding straps and/or grounding rings to protect the flow signal against stray electrical noise. This ensures that the noise is carried through the sensor body and a noise-free measuring area within the sensor body. For MAG 8000 Irrigation grounding rings on both sides are factory-mounted. Metal pipes M6 x 16 On metal pipes, connect the straps to both flanges. 3 Metal pipe Metal pipe The selected calibration determines the accuracy of the meter. A standard calibration results in max. 0.4 % uncertainty and an extended calibration 0.2 % (for MAG 8000 irrigation ± 0.8 %). A calibration certificate follows every sensor and calibration data are stored in the meter unit. Plastic pipes On plastic pipes and lined metal pipes, optional grounding rings must be used at both ends. Grounding rings has to be ordered separately see „Grounding ring kit“ ± E% 1.2 Plastic pipe Error Plastic pipe Standard calibration (7ME688) E=± 0.8 % of rate ± 2.5 mm/s 1.0 0.8 0.6 Standard calibration (7ME681) E=± 0.4 % of rate ± 2 mm/s 0.4 Combination of metal and plastic pipes M6 x 16 A combination of metal and plastic requires straps for metal pipe and grounding rings for plastic pipe. Extended calibration(7ME681) E=± 0.2 % of rate ± 2 mm/s 0.2 0.0 0 2 4 6 8 10 12 m/s Flowrate Metal pipe Plastic pipe MAG 8000 (7ME6810) for Fire Service applications MAG 8000 (7ME6810) is FM Fire Service approved for automatic fire protection systems according to the Fire Service Meters Standard, Class Number 1044. The approval is applicable for the sizes DN 50, DN 80, DN 100, DN 150, DN 200, DN 250, and DN 300 (2", 3", 4", 6", 8", 10", and 12") with ANSI B16.5 Class 150 flanges. The FM Fire Service approved product can be ordered via the Z-options P20, P21 and P22 Battery operation time and calculation The battery operation time depends on the connected battery pack as well as the operation condition of the meter. MAG 8000 calculates the remaining capacity every 4 hours and includes all consuming elements. Calculation compensates for temperature influence on battery capacity. ±E% 20 1.5 % Qmin Capacity to 2 Volts/Ah FM Fire Service verification tolerances Available capacity 0.6 mA 15 10 Qmax 0 -50 -35 -20 -5 10 25 40 55 70 85 100 (-58) (-31) (-4) (23) (50) (77) (104) (131)(158)(185) (212) Temperature °C (°F) The graphic shows the effect from other temperatures. A variation in temperature from 15 °C to 55 °C (59 to 131 °F) reduces the capacity by 17 % from 15 Ah to 12.5 Ah. At typical revenue scenario of expected battery operation time can be seen in the table below. The measurement for calculating the rest capacity of the battery life time is only completed if the system has no active fatal faults or the empty pipe is active. Maximum battery specification is 10 years operation. Siemens FI 01 · 2016 3/121 © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 Scenario - Revenue application 3 Output A Pulse rate max. 10 Hz Output B Alarm or call-up Meter dialog 1 hour per month Add-com None Temperature • 5 % at 0 °C (32 °F) • 80 % at 15 °C (59 °F) • 15 % at 50 °C (122 °F) Battery lifetime (subject to the assumptions mentioned above) MAG 8000 for abstraction and distribution network applications (7ME6810) and MAG 8000 CT for revenue and bulk metering (7ME6820) Excitation frequency (24 h operation) 1/60 Hz 1/30 Hz 1/15 Hz 1/5 Hz 1.5625 Hz 3.125 Hz 6.25 Hz 2 D-Cell battery 33 Ah Internal battery pack DN 25 ... 200 (1" ... 8") 8 years 8 years 6 years 40 months 8 months 4 months 2 months DN 250 … 600 (10" ... 24") 8 years 6 years 4 years 20 months 4 months 2 months N/A DN 700 ... 1 200 (28" ... 48") 6 years 4 years 2 years 1 year 2 months N/A N/A DN 25 ... 200 (1" ... 8") N/A 10 years 10 years 80 months 16 months 8 months 4 months DN 250 ... 600 (10" ... 24") N/A 10 years 8 years 40 months 8 months 4 months N/A DN 700 ... 1 200 (28" ... 48") 10 years 8 years 4 years 2 years 4 months N/A N/A 4 D-Cell battery 66 Ah External battery pack MAG 8000 for irrigation applications (7ME6880) Excitation frequency (24 h operation) 1/60 Hz 1/30 Hz 1/15 Hz 1/5 Hz 1.5625 Hz 3.125 Hz 1 D-Cell battery Internal battery pack DN 25 ... 600 (1" ... 24") 52 months 40 months 25 months 12 months 2 months 1 month DN 700 ... 1 200 (28" ... 48") 3 years 2 years 1 years 6 months 1 month N/A 2 D-Cell battery 33 Ah Internal battery pack DN 50 … 600 (2" ... 24") 8 years 80 months 50 months 24 months 4 months 2 months DN 700 ... 1 200 (28" ... 48") 6 years 4 years 2 years 1 year 2 months N/A 4 D-Cell battery 66 Ah External battery pack DN 50 ... 600 (2" ... 24") 10 years 10 years 8 years 48 months 8 months 4 months DN 700 ... 1 200 (28" ... 48") 10 years 8 years 4 years 2 years 4 months N/A MAG 8000 GSM/GPRS battery lifetime scenario Transmission once a day and MAG 8000 factory settings 2 D-Cell battery 33 Ah Internal battery pack 3 years 4 D-Cell battery 66 Ah External battery pack 7 years External battery pack can be used as battery backup for mains power supply (if two cable entries in one cable gland are needed, order cable glands with two entries, see accessories on page 3/139). Serial RS 232/RS 485 add-on communication modules are designed for mains powered systems as the battery operation time will be reduced. At 1 hour communication per month (all meter data collected 2 times per day) and the module is connected, the operation time is reduced to: • RS 232: - low excitation frequency: 10 % of calculated operation time - high excitation frequency: 80 % of calculated operation time • RS 485: - low excitation frequency: 50 % of calculated operation time - high excitation frequency: 90 % of calculated operation time 3/122 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 for abstraction and distribution network applications (7ME6810) ■ Overview ■ Technical specifications Meter Accuracy Standard calibration: ± 0.4 % of rate ± 2 mm/s Extended calibration DN 50 ... DN 300 (2" ... 12"): ± 0.2 % of rate ± 2 mm/s Low flow cut-off (default) 0.05 % Media conductivity Clean water > 20 s/cm Temperature Ambient -20 ... +60 °C (-4 ... +140 °F) Media 0 ... 70 °C (32 ... 158 °F) Storage -40 ... +70 °C (-40 ... +158 °F) Enclosure rating Remote sensor IP68 to EN 60529/NEMA 6P, 10 mH2O cont. Compact version IP68 to EN 60529/NEMA 6P, 3 mH2O for six months Certificates and approvals Calibration • Standard calibration • Special calibration ■ Benefits Easy to install • Compact or remote solution with factory mounted cable • IP68/NEMA 6P enclosure. Sensor can be buried. • Flexible power supply - internal or external battery pack or mains power supply with battery back-up possibilities Long-term stability/Low cost of ownership • No moving parts in a robust construction means less wear and tear • Basic and advanced transmitter versions with different optional add-on communication modules fulfil various customer requirements for high cost efficiency • Up to 0.2 % maximum uncertainty • Bi-directional measurement with an outstanding low flow performance • Up to 10 years maintenance-free operation in typical applications Intelligent information, easy to access • Advanced information on site • Advanced statistics and diagnostics • Optional high-performance GSM/GPRS module offers an efficient solution for remote measurement and monitor via wireless communication. Material certificate EN 10204-3.1 Drinking water approvals Fire Service Approvals Conformity 2 x 25 % and 2 x 90 % (default) 5-point calibration: 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 10-point calibration: ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax Matched-pair calibration: default, 5-point, 10-point Available when ordering together with meter1) • NSF/ANSI Standard 612) (cold water) USA • WRAS (BS 6920 cold water) UK • ACS Listed France • DVGW W270 Germany • Belgaqua (B) • MCERTS (GB) FM Fire Service Meter (Class Number 1044)3) • PED: 97/23EC4) For pressure/temperature curves see MAG 3100 on page 3/70. • EMC: IEC/EN 61326 Sensor version DN 25 … 1200 (1" … 48") Sensor material Carbon steel ASTM A 105, with corrosion resistant two-component epoxy coating (150 m/300 m) Corrosivity category C4, according to ISO 12944-2 Measuring principle Electromagnetic induction Excitation frequency Basic version • Battery-powered DN 25 ... 150 (1” ... 6”): 1/15 Hz DN 200 … 600 (8” … 24”): 1/30 Hz DN 700 ... 1200 (28“ ... 48“): 1/60 Hz • Mains-powered DN 25 ... 150 (1” ... 6”): 6.25 Hz DN 200 … 600 (8” … 24”): 3.125 Hz DN 700 ... 1200 (28“ ... 48“): 1.5625 Hz Siemens FI 01 · 2016 3/123 3 © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 for abstraction and distribution network applications (7ME6810) Advanced version 3 • Battery-powered DN 25 ... 150 (1” ... 6”): 1/15 Hz (adjustable up to 6.25 Hz; reduced battery lifetime) DN 200 … 600 (8” … 24”): 1/30 Hz (adjustable up to 3.125 Hz; reduced battery lifetime) DN 700 ... 1200 (28“ ... 48“): 1/60 Hz (adjustable up to 1.5625 Hz; reduced battery lifetime) • Mains-powered DN 25 ... 150 (1” ... 6”): 6.25 Hz DN 200 … 600 (8” … 24”): 3.125 Hz DN 700 ... 1200 (28“ ... 48“): 1.5625 Hz Flanges EN 1092-1 (DIN 2501) DN 25 and DN 40 (1" and 1½"): PN 40 (580 psi) DN 50 … 150 (2" … 6"): PN 16 (232 psi) DN 200 … 1200 (8" … 48"): PN 10 or PN 16 (145 psi or 232 psi) ANSI 16.5 Class 150 1” … 24”: 20 bar (290 psi) AWWA C-207 28" … 48": PN 10 (145 psi) AS 4087 DN 50 … 1200 (2" … 48"): PN 16 (232 psi) Liner EPDM Electrode and grounding electrodes Hastelloy C276/2.4819 Grounding straps Grounding straps are premounted from the factory on each side of the sensor. 1) Has to be ordered with the meter. It is not possible to order the certificate afterwards. 2) Including Annex G 3) Not for sensors with 300 m coating. 4) For further information on the PED standard and requirements see page 9/6. 3/124 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 for abstraction and distribution network applications (7ME6810) Selection and Ordering data Article No. Selection and Ordering data SITRANS F M MAG 8000 water meter 7 ME 6 8 1 0 77777 - 7777 SITRANS F M MAG 8000 water meter Click on the Article No. for the online configuration in the PIA Life Cycle Portal. 2D 2R 2Y DN 65 (2½“) DN 80 (3“) DN 100 (4“) 3F 3M 3T DN 125 (5“) DN 150 (6“) DN 200 (8“) 4B 4H 4P DN 250 (10“) DN 300 (12“) DN 350 (14“) 4V 5D 5K DN 400 (16“) DN 450 (18“) DN 500 (20“) DN 600 (24“) 5R 5Y 6F 6P DN 700 (28“)1) DN 750 (30“)1) DN 800 (32“)1) DN 900 (36“)1) DN 1000 (40“)1) 6Y 7D 7H 7M Flange norm and pressure rating EN 1092-1 PN 10 (DN 200 ... 1200 (8" ... 48")) PN 16 (DN 50 ... 1200 (2" ... 48")) PN 16 non-PED (DN 700 .... 1200 ( 28"... 48")) PN 40 (DN 25 ... 40 (1" ... 1½“)) ANSI B16.5 Class 150 AWWA C-207 Class D (28" ... 48") AS4087 PN 16 (DN 50 ... 1200 (2" ... 48")) Sensor version EPDM liner and Hastelloy electrodes, 150 m coating EPDM liner and Hastelloy electrodes , 300 m coating No additional "add-on" communication module installed Serial RS 485 with Modbus RTU (Terminated as end device) Serial RS 232 with Modbus RTU Encoder interface with Sensus protocol GSM/GPRS communication module with remote antenna; 5 m (16.4 ft) cable GSM/GPRS communication module with analog inputs and remote antenna; 5 m (16.4 ft) cable 3 A B C D S T 0 1 2 12/24 V AC/DC power supply with battery backup and 3 m (9.8 ft) power cable for external connection (no battery included) 115 ... 230 V AC power supply with battery backup and 3 m (9.8 ft) power cable for external connection (no battery included) 3 Internal battery (no battery included) Internal battery pack installed2) Power cable (1.5 m (4.9 ft)) with IP68/NEMA 6P plugs for external battery (no battery included) 1) B C D F 4 The Diameter DN 700 (28") to DN 1200 (48") is only available as remote transmitter type installation. Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and UN 3091". Special transport documentation is required to observe these regulations. This may influence both transport time and costs. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Operating instructions for SITRANS F M MAG 8000 J L N 3 4 Description Article No. • English A5E03071515 • German A5E00740986 This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Operating instructions for MAG 8000 GSM/GPRS communication module Calibration Standard ± 0.4 % of rate ± 2 mm/s Extended ± 0.2 % of rate ± 2 mm/s DN 50... 300 (2" ... 12") Power supply 2) L M N P Communication interface 7R 7U 7V 8B DN 1050 (42“)1) DN 1100 (44“)1) DN 1200 (48“)1) 7 ME 6 8 1 0 77777 - 7777 Advanced version, remote cables mounted on sensor with IP68/NEMA 6P plugs: • 5 m (16.4 ft) • 10 m (32.8 ft) • 20 m (65.6 ft) • 30 m (98.4 ft) Diameter DN 25 (1“) DN 40 (1½“) DN 50 (2“) Article No. 1 2 Description Article No. • English A5E03644134 Region version Europe (m3, m3/h, 50 Hz) USA (Gallon, GPM, 60 Hz) Australia (Ml, Ml/d, 50 Hz) 1 2 3 Transmitter type and installation Basic version integral on sensor Basic version, remote cables mounted on sensor with IP68/NEMA 6P plugs: • 5 m (16.4 ft) • 10 m (32.8 ft) • 20 m (65.6 ft) • 30 m (98.4 ft) Advanced version integral on sensor A B C D E K Siemens FI 01 · 2016 3/125 © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 for abstraction and distribution network applications (7ME6810) Selection and Ordering data Order code Additional information Please add “-Z“ to Article No. and specify Order code(s) and plain text. Please add “-Z“ to Article No. and specify Order code(s) and plain text. Certificate Material certificate according to EN 10204-3.1 C121) Special calibration 3 Selection and Ordering data Additional information 5-point calibration for DN 15 ... DN 2002) 5-point calibration for DN 250 ... DN 6002) 5-point calibration for DN 700 ... DN 12002) D01 D02 D03 10-point calibration for DN 15 ... DN 2003) 10-point calibration for DN 250 ... DN 6003) 10-point calibration for DN 700 ... DN 12003) D06 D07 D08 Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 15 ... DN 200 Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 250 ... DN 600 Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 700 ... DN 1200 D11 5-point, matched-pair calibration for DN 15 ... DN 2002) 5-point, matched-pair calibration for DN 250 ... DN 6002) 5-point, matched-pair calibration for DN 700 ... DN 12002) D15 10-point, matched-pair calibration for DN 15 ... DN 2003) 10-point, matched-pair calibration for DN 250 ... DN 6003) 10-point, matched-pair calibration for DN 700 ... DN 1200 3) D18 D12 D13 D16 D17 D19 D20 Flow unit l/s MGD CFS L00 L01 L02 l/min m3/min GPM L03 L04 L05 CFM l/h m3/h L06 L07 L08 GPH CFH GPS L09 L10 L11 Ml/d m3/d GPD L12 L13 L14 BBL42/s BBL42/min BBL42/h BBL42/d L15 L16 L17 L18 Totalizer Volume calculation (default totalizer 1= forward and totalizer 2 = reverse) Totalizer 1 = RV, reverse flow Totalizer 1 = NET, net flow Totalizer 2 = FW, forward flow Totalizer 2 = NET, net flow L20 L22 L30 L31 Volume unit m3 Ml G L40 L41 L42 AF l x 100 m3 x 100 L43 L44 L45 3/126 Siemens FI 01 · 2016 Order code G x 100 CF x 100 MG L46 L47 L48 G x 1000 CF x 1000 AI L49 L50 L51 kI BBL42 (US oil barrel, 1 barrel = 42 US gallons) L52 L54 Pulse set up (default pulse A = forward and pulse B = Alarm, pulse width = 50 ms) A function = RV, reverse flow A function = FWnet, forward net flow A function = RVnet, reverse net flow A function = Off L62 L63 L64 L65 Volume per pulse A = x 0.00014) Volume per pulse A = x 0.0014) Volume per pulse A = x 0.014) Volume per pulse A = x 0.14) Volume per pulse A = x 14) L70 L71 L72 L73 L74 B function = FW, forward flow B function = RV, verse flow B function = FWnet, forward net flow L80 L81 L82 B function = RVnet, reverse net flow B function = Alarm B function = Call up L83 L84 L85 Volume per pulse B = x 0.00014) Volume per pulse B = x 0.0014) Volume per pulse B = x 0.014) L90 L91 L92 Volume per pulse B = x 0.14) Volume per pulse B = x 14) L93 L94 Data logger set up (default month logging) DataloggerInterval = Daily DataloggerInterval = Weekly M31 M32 Factory mounted cables 5 m (16.4 ft) pulse cable A+B 5 m (16.4 ft) communication cable RS 232/RS 485 terminated as end device M81 M82 20 m (65.6 ft) pulse cable A+B 20 m (65.6 ft) communication cable RS 232/RS 485 terminated as end device Cello 2 channel, input cable 3 m (9.84 ft) with Brad Harrison micro-change 3 way connector Cello 2 channel, input cable 5 m (16.4 ft) with MIL-C-26482 spec. connectors Encoder interface cable with connector for ITRON 200WP radio, lenght 25 ft Encoder interface cable with connector for ITRON 200WP radio, length 5 ft SOFREL data logger cable 2 m with connector for SOFREL GSM module M84 M85 FM Fire Service Approval (with ANSI B16.5 Class 150 flanges) DN 50, DN 80 and DN 100 (2“, 3" and 4") DN 150 and DN 200 (6" and 8") DN 250 and DN 300 (10" and 12") M87 M89 M90 M91 M92 P20 P21 P22 1) Under preparation 2) 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 3) Ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 4) Pulse width = 10 ms © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 CT for revenue and bulk metering (7ME6820) ■ Overview ■ Technical specifications Meter Accuracy OIML R 49/OIML R 49 MAA for DN 50 ... DN 300 (2" ... 12"), Class I and II with turn down up to Q3/Q1 = 400 at Q2/Q1 =1.6 MI-001 verification for DN 50 … DN 600 (2" ... 24"), Class II with turn down ratio Q3/Q1 = 250, Q3/Q1 = 200 or Q3/Q1 = 160 at Q2/Q1 = 1.6 FM Fire Service for DN 50, DN 80, DN 100, DN 150, DN 200, DN 250, and DN 300 (2", 3", 4", 6", 8", 10", and 12") 1.5% (Qmin to Qmax) Low flow cut-off (default) 0.25 % Media conductivity Clean water > 20 s/cm Temperature Ambient -20 ... +60 °C (-4 ... +140 °F) MI-001: -25 ... +55 ºC (-13 ... +131 ºF) Media 0.1 ... 50 °C (32 ... 122 °F) Storage -40 ... +70 °C (-22 ... +158 °F) ■ Benefits Approvals • MI-001, OIML R 49/OIML R 49 MAA • PTB K7.2 • FM Fire Service Easy to install • Compact or remote solution with factory mounted cable and customer setting from factory • IP68/NEMA 6P enclosure. Sensor can be buried • Flexible power supply - internal or external battery pack or mains power supply with battery back-up possibilities Long-term stability/Low cost of ownership • No moving parts in a robust construction means less wear and tear • Basic and advanced transmitter versions with different optional add-on communication modules fulfil various customer requirements for high cost efficiency • Bi-directional measurement with an outstanding low flow performance • Up to 10 years maintenance-free operation in typical applications • Insignificant pressure drop Enclosure rating Remote sensor IP68 to EN 60529/NEMA 6P, 10 mH2O cont. Compact version IP68 to EN 60529/NEMA 6P, 3 mH2O for six months Certificates and approvals Calibration (standard) Material certificate EN 10204 3.1 2 x 25 % and 2 x 90 % Available when ordering together with meter1) Drinking water approvals • NSF/ANSI Standard 612) (cold water) USA • WRAS (BS 6920 cold water) UK • ACS Listed France • DVGW W270 Germany • Belgaqua (B) • MCERTS (GB) Fire Service approval FM Fire Service (1044)3) Custody transfer approval • OIML R 49 and OIML R 49 MAA approval (DN 50 ... DN 300 (2" ... 12")) • MI-001 approval (DN 50 ... DN 600 (2" ... 24")) (DK-0200-MI-001-011) • PTB K7.2 Conformity • CEN EN 14154, ISO 4064 • PED: 2014/68/EU4) For pressure/temperature curves, see MAG 3100 on page 3/70. • EMC: IEC/EN 61326 Sensor version DN 50 ... 600 (2" ... 24") Sensor material Carbon steel ASTM A 105, with corrosion resistant two-component epoxy coating (150 m/300 m) Corrosivity category C4, according to ISO 12944-2 Measuring principle Electromagnetic induction Intelligent information, easy to access • Advanced information on site • Advanced statistics and diagnostics • Connectable to common AMR systems Excitation frequency Basic version • Battery-powered • Mains-powered DN 50 ... 150 (2” ... 6”): 1/15 Hz DN 200 … 600 (8” … 24”): 1/30 Hz DN 50 ... 150 (2” ... 6”): 6.25 Hz DN 200 … 600 (8” … 24”): 3.125 Hz Siemens FI 01 · 2016 3/127 3 © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 CT for revenue and bulk metering (7ME6820) Advanced version • Battery-powered DN 50 ... 150 (2” ... 6”): 1/15 Hz (adjustable up to 6.25 Hz; reduced battery lifetime) DN 200 … 600 (8” … 24”): 1/30 Hz (adjustable up to 3.125 Hz; reduced battery lifetime) DN 50 ... 150 (2” ... 6”): 6.25 Hz DN 200 … 600 (8” … 24”): 3.125 Hz • Mains-powered Flanges EN 1092-1 (DIN 2501) 1) Has to be ordered with the meter. It is not possible to order the certificate afterwards. 2) Including Annex G 3) Not for sensors with 300 m coating. 4) For further information on the PED standard and requirements see page 9/6. DN 50 … 150 (2" … 6"): PN 16 (232 psi) DN 200 … 300 (8" … 12"): PN 10 or PN 16 (145 psi or 232 psi) up to DN 600 (24") in preparation 2” … 12”: 20 bar (290 psi) up to DN 600 (24") in preparation 28" … 48": PN 10 (145 psi) DN 50 … 300 (2" … 12"): PN 16 (232 psi) up to DN 600 (24") in preparation 3 ANSI 16.5 Class 150 AWWA C-207 AS 4087 Liner EPDM Electrode and grounding electrodes Hastelloy C276/2.4819 Grounding straps Grounding straps are premounted from the factory on each side of the sensor MAG 8000 CT (Revenue program) water meter type approval MAG 8000 CT program is type approved and verified according to international water meter standard OIML R 49. The custody transfer program is approved as Class I and Class II, for the sensor program from DN 50 to DN 300, at different Q3 and Q3/Q1. Q2/Q1 = 1.6 and follows OIML R 49 specification. ±E% Cl. II = 5% Cl. I = 3% Cl. II = 2% Cl. I = 1% Q1 Q2 Q3 Cl. I / Cl. II = OIML R 49 Class I / Class II Q4 OIML R 49/2006-DK2-10.01 Revision 1 approval specification for Class I (1 %)1) Size DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600 (4“) (5“) (6“) (8“) (10“) (12“) (14“) (16“) (18“) (20“) (24“) „R“ Q3/Q1 250 250 250 250 250 250 250 250 125 - - - - - Q1 [m3/h] 0.25 0.40 0.63 1.00 160 2.50 4.00 6.40 12.8 - - - - - Q2 [m3/h] 0.40 0.64 1.00 1.60 2.60 4.00 6.40 10.24 20.48 - - - - - Q3 [m3/h] 63 100 160 250 400 630 1000 1600 1600 - - - - - Q4 [m3/h] 78.75 125 200 312.5 500 787.5 1250 2000 2000 - - - - - OIML R 49/2006-DK2-10.01 Revision 1 approval specification for Class II (2 %)1) Size DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600 (4“) (5“) (6“) (8“) (10“) (12“) (14“) (16“) (18“) (20“) (24“) „R“ Q3/Q1 400 400 400 400 400 400 400 400 200 - - - - - Q1 [m3/h] 0.16 0.25 0.40 0.63 1.00 1.60 2.50 4.00 10.00 - - - - - Q2 [m3/h] 0.25 0.40 0.63 1.00 1.60 2.50 4.00 6.40 16.00 - - - - - Q3 [m3/h] 63 100 160 250 400 630 1000 1600 1600 - - - - - Q4 [m3/h] 78.75 125 200 312.5 500 787.5 1250 2000 2000 - - - - - 1) The product will be delivered according to requested specifications, which may deviate from the specifications of the approval frame described in tables below. 3/128 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 CT for revenue and bulk metering (7ME6820) MAG 8000 CT (Revenue program) MI-001 MAG 8000 CT program is type approved according to international water meter standard OIML R 49. Since the first November 2006 the MI-001 water meter directive is in force, which means that all water meters can be sold across the EU borders if the water meters contain a MI-001 label. The MAG 8000 CT MI-001 verified and labeled products are a Class II aproval according to Directive 2014/32/EU of the European Parliament and Council of 26 February, 2014 on measuring instruments, Annex VI Thermal Energy Meters (MI-004) in the sizes from DN 50 to DN 400. The MID certification is obtained as a B + D module approval according to the above mentioned directive. Module B : Type approval according to OIML R 49 Module D : Quality insurance approval of production 3 MI-001 verification tolerances ±E% Cl. II = 5% Cl. II = 2% Q1 Q2 Q3 Q4 MAG 8000 CT MI-001 verified and labeled products at a given Q3 and Q4/Q3 = 1.25 and Q2/Q1 = 1.6 measuring ranges see below table: 7ME6820xxxx1 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600 (4“) (5“) (6“) (8“) (10“) (12“) (14“) (16“) (18“) (20“) (24“) „R“ Q3/Q1 25 25 25 25 25 25 25 25 25 25 25 25 25 25 Q4 [m3/h] 20 31.25 50 78.75 125 200 312.5 500 787.5 1250 1250 1250 2000 3125 [m3/h] Q3 16 25 40 63 100 160 250 400 630 1000 1000 1000 1600 2500 Q2 [m3/h] 0.96 1.60 2.60 4.03 6.40 10.24 16 25.60 40.3 64 64 64 102.4 160 Q1 [m3/h] 0.60 1 1.60 2.52 4 6.40 10 16 25.2 40 40 40 64 100 7ME6820xxxx2 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600 (4“) (5“) (6“) (8“) (10“) (12“) (14“) (16“) (18“) (20“) (24“) „R“ Q3/Q1 63 63 63 63 63 63 63 63 63 63 63 63 63 63 Q4 [m3/h] 20 31.25 50 78.75 125 200 312.5 500 750 1250 1250 3125 3125 5000 Q3 [m3/h] 16 25 40 63 100 160 250 400 630 1000 1000 2500 2500 4000 Q2 [m3/h] 0.41 0.63 1.02 1.60 2.54 4.06 6.35 10.16 16 25.4 25.4 63.49 63.49 101.6 [m3/h] 0.25 0.40 0.63 1 1.59 2.54 3.97 6.35 10 15.9 15.9 39.68 39.68 63.49 7ME6820xxxx3 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600 (4“) (5“) (6“) (8“) (10“) (12“) (14“) (16“) (18“) (20“) (24“) „R“ Q3/Q1 80 80 80 80 80 80 80 80 80 80 80 80 80 80 [m3/h] 20 31.25 50 78.75 125 200 312.5 500 1250 2000 2000 5000 5000 7875 Q3 [m3/h] 16 25 40 63 100 160 250 400 1000 1600 1600 4000 4000 6300 Q2 [m3/h] 0.32 0.50 0.80 1.20 2 3.20 5 8 20 32 32 80 80 126 Q1 [m3/h] 0.20 0.31 0.50 0.75 1.25 2 3.13 5 12.50 20 20 50 50 78.75 7ME6820xxxx4 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600 (4“) (5“) (6“) (8“) (10“) (12“) (14“) (16“) (18“) (20“) (24“) „R“ Q3/Q1 160 160 160 160 Q1 Q4 160 160 160 160 160 - - - - - 2000 - - - - - - - - - Q4 [m3/h] Q3 [m3/h] 40 63 100 160 250 400 630 1000 1600 - Q2 [m3/h] 0.40 0.63 1 1.60 2.50 4 6.30 10 16 - - - - - Q1 [m3/h] 0.25 0.39 0.63 1 1.56 2.50 3.94 6.25 10 - - - - - 7ME6820xxxx5 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600 (4“) (5“) (6“) (8“) (10“) (12“) (14“) (16“) (18“) (20“) (24“) „R“ Q3/Q1 200 200 200 200 200 200 200 200 200 - - - - - Q4 [m3/h] 50 78.75 125 200 312.5 500 787.5 1250 2000 - - - - - Q3 [m3/h] 40 63 100 160 250 400 630 1000 1600 - - - - - 8 12.8 - - - - - 5 8 - - - - - Q2 [m3/h] Q1 [m3/h] 50 0.32 0.20 78.75 0.50 0.32 125 0.80 0.50 200 1.28 0.80 312.5 2 1.25 500 3.20 2 787.5 5.04 3.15 1250 Siemens FI 01 · 2016 3/129 © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 CT for revenue and bulk metering (7ME6820) 7ME6820xxxx6 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600 (4“) (5“) (6“) (8“) (10“) (12“) (14“) (16“) (18“) (20“) (24“) „R“ Q3/Q1 250 250 250 250 250 250 250 250 - - - - - - Q4 [m3/h] 50 78.75 125 200 312.5 500 787.5 1250 - - - - - - - - Q3 [m3/h] 40 63 100 160 250 400 630 1000 - - - - [m3/h] 0.26 0.40 0.64 1.02 1.60 2.56 4 6.40 - - - - - - Q1 [m3/h] 0.16 0.25 0.40 0.64 1 1.60 2.52 4 - - - - - - Q2 3 The Label is placed on the side of the encapsulation. An example of the product label is shown below: MAG 8000 CT (7ME6820) for Fire Service applications MAG 8000 CT (7ME6820) is FM Fire Service approved for automatic fire protection systems according to the Fire Service Meters Standard, Class Number 1044. The approval is applicable for the sizes DN 50, DN 80, DN 100, DN 150, DN 200, DN 250, and DN 300 (2", 3", 4", 6", 8", 10", and 12") with ANSI B16.5 Class 150 flanges. The FM Fire Service approved product can be ordered via the Z-options P20, P21 and P22. ±E% FM Fire Service verification tolerances Installation conditions Please refer to “System information SITRANS F M electromagnetic flowmeters”. Battery operation time and calculation The battery operation time depends on the connected battery pack as well as the operation condition of the meter. MAG 8000 calculates the remaining capacity every 4 hours and includes all consuming elements. Calculation compensates for temperature influence on battery capacity (drawing). 3/130 Siemens FI 01 · 2016 1.5 % MAG 8000 CT Qmin Qmax © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 CT for revenue and bulk metering (7ME6820) Selection and Ordering data Article No. Article No. Selection and Ordering data SITRANS F M SITRANS F M MAG 8000 CT water meter with EPDM liner and Hastelloy electrodes 7ME 6 8 2 0 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. 2Y 3F 3M DN 100 (4“) DN 125 (5“) DN 150 (6“) 3T 4B 4H DN 200 (8“) DN 250 (10“) DN 300 (12“) 4P 4V 5D DN 350 (14")1) DN 400 (16")1) DN 450 (18")1) 5K 5R 5Y DN 500 (20")1) DN 600 (24")1) 6F 6P C ANSI B16.5 Class 150 J AS4087 PN 16 N 0 4 3 S T 12/24 V AC/DC power supply with battery backup and 3 m (9.8 ft) power cable for external connection (no battery included) 115 ... 230 V AC power supply with battery backup and 3 m (9.8 ft) power cable for external connection. (no battery included) 3 4 Under preparation. Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and UN 3091". Special transport documentation is required to observe these regulations. This may influence both transport time and costs. 3) For more details and references of the ranges please see the tables on pages 3/128 to 3/130. 4) Standard calibration or according to FM Fire Service requirements if P20, P21 or P22 is selected as Z option. Operating instructions for SITRANS F M MAG 8000 Description 0 1 2 3 4 5 6 7 Article No. • English A5E03071515 • German A5E00740986 This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Operating instructions for MAG 8000 GSM/GPRS communication module 8 Region version Europe (m3, m3/h, 50 Hz) USA (m3, m3/h, 60 Hz) C D 0 1 2 1) 3) Approval/Verification Without verification according to OIML R 494) MI-001 Q3/Q1 = 25 MI-001 Q3/Q1 = 63 MI-001 Q3/Q1 = 80 MI-001 Q3/Q1 = 160 MI-001 Q3/Q1 = 200 MI-001 Q3/Q1 = 250 Without verification calibrated to OIML R 49-Class II (Q3/Q1 = 100) Without verification calibrated to OIML R 49-Class II (Q3/Q1 = 250) B Internal battery (no battery included) Internal battery pack installed2) Power cable (1.5 m (4.9 ft)) with IP68/NEMA 6P plugs for external battery (no battery included) 2) Sensor version EPDM liner and Hastelloy electrodes, 150 m coating EPDM liner and Hastelloy electrodes, 300 m coating A Power supply Flange norm and pressure rating EN 1092-1 PN 16 7ME 6 8 2 0 77777 - 7777 Communication interface No additional "add-on" communication module installed Serial RS 485 with Modbus RTU (Terminated as end device) Serial RS 232 with Modbus RTU Encoder interface for ITRON 200WP radio with "Sensus" protocol" GSM/GPRS communication module with remote antenna; 5 m (16.4 ft) cable GSM/GPRS communication module with analog inputs and remote antenna; 5 m (16.4 ft) cable Diameter DN 50 (2“) DN 65 (2½“) DN 80 (3“) MAG 8000 CT water meter with EPDM liner and Hastelloy electrodes Description Article No. • English A5E03644134 1 2 Transmitter type and installation Basic version integral on sensor Basic version, remote cables mounted on sensor with IP68/NEMA 6P plugs 5 m (16.4 ft) 10 m (32.8 ft) 20 m (65.6 ft) 30 m (98.4 ft) A Advanced version integral on sensor Advanced version, remote cables mounted on sensor with IP68/NEMA 6P plugs 5 m (16.4 ft) 10 m (32.8 ft) 20 m (65.6 ft) 30 m (98.4 ft) K B C D E L M N P Siemens FI 01 · 2016 3/131 © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 CT for revenue and bulk metering (7ME6820) Selection and Ordering data Order code Additional information Please add “-Z“ to Article No. and specify Order code(s) and plain text. Material certificate according to EN 10204-3.1 C121) FP2E marking (France only) C17 Totalizer Volume calculation (default totalizer 1= forward and totalizer 2 = reverse) 3 Totalizer 1 = RV, reverse flow Totalizer 1 = NET, net flow Totalizer 2 = FW, forward flow Totalizer 2 = NET, net flow L20 L22 L30 L31 Pulse set up (default pulse A = forward and pulse B = Alarm, pulse width = 50 ms) A function = RV, reverse flow A function = FWnet, forward net flow A function = RVnet, reverse net flow A function = Off L62 L63 L64 L65 Volume per pulse A = x 0.0012) Volume per pulse A = x 0.012) Volume per pulse A = x 0.12) Volume per pulse A = x 12) L71 L72 L73 L74 B function = FW, forward flow B function = RV, reverse flow B function = FWnet, forward net flow L80 L81 L82 B function = RVnet, reverse net flow B function = Alarm B function = Call up L83 L84 L85 Volume per pulse B = x 0.0012) Volume per pulse B = x 0.012) L91 L92 Volume per pulse B = x 0.12) Volume per pulse B = x 12) L93 L94 Data logger set up (default month logging) DataloggerInterval = Daily DataloggerInterval = Weekly M31 M32 Factory mounted cables 5 m (16.4 ft) pulse cable A+B 5 m (16.4 ft) communication cable RS 232/RS 485 terminated as end device M81 M82 20 m (65.6 ft) pulse cable A+B 20 m (65.6 ft) communication cable RS 232/RS 485 terminated as end device Cello 2 channel, input cable 3 m (9.84 ft) with Brad Harrison micro-change 3 way connector Cello 2 channel, input cable 5 m (16.4 ft) with MIL-C-26482 spec. connectors 5 ft. Encoder interface cable with connector for ITRON 200WP radio 25 ft. Encoder interface cable with connector for ITRON 200WP radio SOFREL data logger cable 2 m with connector for SOFREL GSM module M84 M85 FM Fire Service Approval (with ANSI B16.5 Class 150 flanges) DN 50, DN 80 and DN 100 (2“, 3" and 4") DN 150 and DN 200 (6" and 8") DN 250 and DN 300 (10" and 12") 1) Under preparation 2) Pulse width = 10 ms 3/132 Siemens FI 01 · 2016 M87 M89 M91 M90 M92 P20 P21 P22 © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 for irrigation applications (7ME6880) ■ Overview Temperature Ambient -20 ... +60 °C (-4 ... +140 °F) Media 0 ... 70 °C (32 ... 158 °F) Storage -40 ... +70 °C (-40 ... +158 °F) Enclosure rating Remote sensor IP68 to EN 60529/NEMA 6P, 10 mH2O cont. Compact version IP68 to EN 60529/NEMA 6P, 3 mH2O for six months Approvals ■ Benefits • IP68/NEMA 6P rating with tamper proof • Flexible power supply - internal or external battery pack or mains power supply with battery back-up possibilities • No moving parts in a robust construction means less wear and tear • Up to 8 years maintenance-free operation in typical application • Connectable to AMR systems • Adaptor for conduit installation to provide a clean, protected pathway for device cables Drinking water approvals • ANSI/NSF 611) (cold water) USA • WRAS (BS 6920 cold water) UK Custody transfer approval NMI M 10 Australia (DN 50 to DN 1200) Sensor material Carbon steel ASTM A 105, with corrosion resistant two-component epoxy coating (150 m/300 m) Corrosivity category C4, according to ISO 12944-2 Conformity IEC/EN 61326 Flanges EN 1092-1 (DIN 2501) PN 10 drilled pattern DN 50 ... 600 (2" ... 24") (max. pressure 7 bar (101.5 psi)) ANSI 16.5 Class 150 drilled pattern 2" ... 24" (max. pressure 7 bar (101.5 psi)) AS 2091-1 Table D drilled pattern DN 50 ... 600 (2" ... 24") (max. pressure 7 bar (101.5 psi)) AS 2129 Table E DN 25, DN 40, DN 125 (1", 1½", 5") AS 4087 PN 16 DN 50 ... DN 1200 (2" ... 48") Excitation frequency ■ Technical specifications Battery-powered DN 50 … 600 (2” … 24”): 1/15 Hz DN 700 … 1200 (28” … 48”): 1/60 Hz Meter Accuracy ± 0.8 % ± 2.5 mm/s ± 0.4 % ± 2.5 mm/s NMI (class 2.5) Low flow cut-off (default) 1.0 % Media conductivity Clean water > 20 s/cm DN 50 … 600 (2” … 24”): 3.125 Hz Mains-powered DN 700 … 1200 (28” … 48”): 1.5625 Hz Liner Ebonite Electrodes Stainless steel AISI 316Ti/1.4571 1) Including Annex G NMI M 10 measuring range 7ME6880 DN 25 (1“) DN 40 (1½“) DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“) DN 350 (14“) „R“ Q3/Q1 10 10 10 10 10 10 10 10 10 10 10 10 Q4 [m3/h] 11.25 28.75 43.75 75 112.5 175 275 375 687.5 750 1625 2125 Q3 [m3/h] 9 23 35 60 90 140 220 300 550 600 1300 1700 0.9 2.3 3.5 6 9 14 22 30 55 60 130 170 7ME6880 DN 400 (16“) DN 450 (18“) DN 500 (20“) DN 600 (24“) DN 700 (28“) DN 750 (30“) DN 800 (32“) DN 900 (36“) DN 1000 (40“) DN 1050 (42“) DN 1100 (44“) DN 1200 (48“) „R“ Q3/Q1 10 10 10 10 10 10 10 10 10 10 10 10 Q4 [m3/h] 2125 2250 2250 2250 4375 4375 5000 5000 5000 5000 5000 5000 Q3 [m3/h] 1700 1800 1800 1800 3500 3500 4000 4000 4000 4000 4000 4000 Q1 [m3/h] 170 180 180 180 350 350 400 400 400 400 400 400 Q1 [m3/h] Siemens FI 01 · 2016 3/133 3 © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 for irrigation applications (7ME6880) Selection and Ordering data Article No. Selection and Ordering data Article No. SITRANS F M MAG 8000 water meter including factory-mounted grounding rings 7 ME 6 8 8 0 - SITRANS F M MAG 8000 water meter including factory-mounted grounding rings 7 ME 6 8 8 0 - 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. No additional "add-on" communication module installed Serial RS 485 with Modbus RTU (Terminated as end device) Serial RS 232 with Modbus RTU Encoder inferface GSM module with remote antenna and 5 m (16.4 ft) cable GSM module with analog input, remote antenna and 5 m (16.4 ft) cable Diameter 3 DN 25 (1“) DN 40 (1½“) DN 50 (2“) 2D 2R 2Y DN 65 (2½“) DN 80 (3“) DN 100 (4“) 3F 3M 3T DN 125 (5“) DN 150 (6“) DN 200 (8“) 4B 4H 4P DN 250 (10“) DN 300 (12“) DN 350 (14“) 4V 5D 5K DN 400 (16“) DN 450 (18“) DN 500 (20“) 5R 5Y 6F DN 600 (24“) DN 700 (28“) DN 750 (30“) 6P 6Y 7D 3 7U 7V 8B 2) B J M G N Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and UN 3091". Special transport documentation is required to observe these regulations. This may influence both transport time and costs. Can be ordered by US region only. Description Article No. • English A5E03071515 • German A5E00740986 All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation 4 Calibration 0 1 3 Region version 1 2 3 Transmitter type and installation Siemens FI 01 · 2016 5 This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. Sensor version 3/134 4 Operating instructions for SITRANS F M MAG 8000 Flange norm and pressure rating Basic version integral on sensor Basic version, remote cables mounted on sensor with IP68/NEMA 6P plugs 2 m (6.56 ft) 5 m (16.4 ft) 10 m (32.8 ft) 20 m (65.6 ft) 30 m (98.4 ft) T 12/24 V AC/DC power supply with battery backup and 3 m (9.8 ft) power cable for external connection (no battery included) 115 ... 230 V AC power supply with battery backup and 3 m (9.8 ft) power cable for external connection (no battery included) Internal battery pack installed 1 D-cell1) 2) DN 1050 (42“) DN 1100 (44“) DN 1200 (48“) Europe (m3, m3/h, 50 Hz) USA (Gallon, GPM, 60 Hz) Australia (Ml, Ml/d, 50 Hz) C D S 0 1 2 7H 7M 7R ± 0.8 %, ± 2.5 mm/s ± 0.4 %, ± 2.5 mm/s NMI (2.5 %) B Internal battery (no battery included) Internal battery pack installed 2 D-cell1) 2) Power cable (1.5 m (4.9 ft)) with IP68/NEMA 6P plugs for external battery (no battery included) DN 800 (32“) DN 900 (36“) DN 1000 (40“) Ebonite liner and stainless steel electrodes A Power supply 1) EN 1092-1 drilled pattern PN 10/max. 7 bar (101 psi) ANSI B16.5 drilled pattern Cl 150/max. 7 bar (101 psi) AS2129 drilled pattern table D/max. 7 bar (101 psi) AS2129 table E (DN 25, DN 40, DN 125) AS4087 PN 16 (DN 50 ... DN 1200) 77777 - 7777 Communication interface A T B C D E © Siemens AG 2016 Flow Measurement SITRANS F M MAG 8000 for irrigation applications (7ME6880) Selection and Ordering data Order code Order code Selection and Ordering data Additional information Additional information Please add “-Z“ to Article No. and specify Order code(s) and plain text. Please add “-Z“ to Article No. and specify Order code(s) and plain text. Flow unit l/s MGD CFS L00 L01 L02 l/min m3/min GPM L03 L04 L05 CFM l/h m3/h L06 L07 L08 GPH CFH GPS L09 L10 L11 Ml/d m3/d GPD L12 L13 L14 Totalizer Volume calculation (default totalizer 1= forward and totalizer 2 = reverse) Totalizer 1 = RV, reverse flow Totalizer 1 = NET, net flow Totalizer 2 = FW, forward flow Totalizer 2 = NET, net flow L20 L22 L30 L31 Volume unit m3 Ml G L40 L41 L42 AF l x 100 m3 x 100 L43 L44 L45 G x 100 CF x 100 MG L46 L47 L48 G x 1000 CF x 1000 AI kI L49 L50 L51 L52 Volume per pulse B = x 0.00011) Volume per pulse B = x 0.0011) Volume per pulse B = x 0.011) L90 L91 L92 Volume per pulse B = x 0.11) Volume per pulse B = x 11) L93 L94 Device operation Only operator menu activated 3 M11 Data logger set up (default month logging) DataloggerInterval = Daily DataloggerInterval = Weekly M31 M32 Factory mounted cables 5 m (16.4 ft) pulse cable A+B 5 m (16.4 ft) communication cable RS 232/RS 485 terminated as end device M81 M82 20 m (65.6 ft) pulse cable A+B 20 m (65.6 ft) communication cable RS 232/RS 485 terminated as end device Cello 2 channel, input cable 3 m (9.84 ft) with Brad Harrison micro-change 3 way connector Cello 2 channel, input cable 5 m (16.4 ft) with MIL-C-26482 spec. connectors 5 ft Encoder interface cable with connector for ITRON 200WP radio 25 ft Encoder interface cable with connector for ITRON 200WP radio SOFREL data logger cable 2 m with connector for SOFREL GSM module Adaptors for conduit installation M84 M85 1) M87 M89 M91 M90 M92 M94 Pulse width = 10 ms Pulse set up (default pulse A = forward and pulse B = Alarm, pulse width = 50 ms) A function = RV, reverse flow A function = FWnet, forward net flow A function = RVnet, reverse net flow A function = Off L62 L63 L64 L65 Volume per pulse A = x 0.00011) Volume per pulse A = x 0.0011) Volume per pulse A = x 0.011) Volume per pulse A = x 0.11) Volume per pulse A = x 11) L70 L71 L72 L73 L74 Pulse A pulse width 5 ms (volume per pulse x 1) Pulse A pulse width 10 ms (volume per pulse x 1) Pulse A pulse width 50 ms (volume per pulse x 1) Pulse A pulse width 100 ms (volume per pulse x 1) Pulse A pulse width 500 ms (volume per pulse x 1) L75 L76 L77 L78 L79 B function = FW, forward flow B function = RV, verse flow B function = FWnet, forward net flow L80 L81 L82 B function = RVnet, reverse net flow B function = Alarm B function = Call up L83 L84 L85 Siemens FI 01 · 2016 3/135 © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 ■ Dimensional drawings 161 (6.34) 161 (6.34) 115 (4.53) 155 (6.10) 155 (6.10) 155 (6.10) 152 (5.98) 152 (5.98) 152 (5.98) M20 M20 A A 3 M20 (½“ NPT) 161 (6.34) A 114 (4.49) 104 (4.09) 84 (3.31) 131 (5.16) L 7ME6810/7ME6820 DN 25 and 40 (1" and 1½") 7ME6880 L L DN 50 ... 300 (2" ... 12") DN 350 ... 1200 (14" ... 48") N/A N/A DN25...600 (1" ... 24") For DN 50 ... 300 (2" ... 12"): Add 7 mm (0.28“) to length (L) For DN 350 ... 1200 (14" ... 48"): Add 8 mm (0.31“) to length (L) Dimensions in mm (inch) Nominal DN size A L, lenghts1) Weight2) EPDM (7ME6810 and 7ME6820) EN 1092-1 PN 10 EN 1092-1 PN 16/ PN 16 non-PED EN 1092-1 PN 40 ANSI 16.5 Class 150 AS 4087 AWWA C-207 AS 2129 PN 16 Class D Table E mm (inch) mm (inch) mm mm mm inch mm mm mm kg lb 25 (1) 188 (7.4) - - 200 7.9 200 - 200 6 13 40 (1½) 203 (8.0) - - 200 7.9 200 - 200 9 20 50 (2) 178 (7.0) - 200 - 7.9 200 - - 11 25 65 (2½) 181 (7.1) - 200 - 7.9 200 - - 13 29 80 (3) 191 (7.5) - 200 - 7.9 200 - - 15 34 100 (4) 197 (7.8) - 250 - 9.8 250 - - 17 38 125 (5) 210 (8.3) - 250 - 9.8 250 - 250 22 50 150 (6) 224 (8.8) - 300 - 11.8 300 - - 28 63 200 (8) 249 (9.8) 350 350 - 13.8 350 - - 50 113 250 (10) 276 (10.9) 450 450 - 17.7 450 - - 71 160 300 (12) 303 (11.9) 500 500 - 19.7 500 - - 88 198 350 (14) 365 (14.4) 550 550 - 21.7 550 - - 127 279 400 (16) 391 (15.4) 600 600 - 23.6 600 - - 145 318 450 (18) 421 (16.6) 600 600 - 23.6 600 - - 175 384 500 (20) 447 (17.6) 600 600 - 26.8 600 - - 225 494 600 (24) 497 (19.6) 600 600 - 32.3 600 - - 340 747 700 (28) 548 (21.6) 700 875/700 - N/A 700 700 - 316 694 750 (30) 573 (22.6) N/A N/A - N/A N/A 750 - N/A N/A 800 (32) 603 (23.7) 800 1000/800 - N/A 800 800 - 398 1045 900 (36) 656 (25.8) 900 1125/900 - N/A 900 900 - 476 1045 1000 (40) 708 (27.9) 1000 1250/1000 - N/A 1000 1000 - 602 1322 1050 (42) 708 (27.9) N/A N/A - N/A N/A 1050 - N/A N/A 1100 (44) 759 (29.9) N/A N/A - N/A N/A 1100 - N/A N/A 1200 (48) 814 (32.0) 1200 1500/1200 - N/A 1200 1200 - 887 1996 1) Tolerances on build in length: DN 15 to DN 200 (½" to 8"): +0/-3 mm (+0/-0.12"), DN 250 to DN 400 (10" to 16"): +0/-5 mm (+0/-0.20"), DN 450 to DN 600 (18" to 24"): +5/-5 mm (+0.20/-0.20"), DN 700 to DN 1200 (28" to 48"): +10/-10 mm (+0.39/-0.39") 2) For remote version the sensor weight is reduced with 2 kg (4.5 lb) 3/136 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 13 (0.51) Remote version 71 (2.80) 31.5 (1.24) 21.5 (0.85) 13 (0.51) 96 (3.78) Ø8 (0.31) 104 (4.09) 164 (6.46) Ø8 (0.31) 120 (4.72) 71 (2.80) Ø12 (0.47) 3 77 (3.03) 50.65 (1.99) 158 (6.22) Dimensions in mm (inch), weight 3.5 kg (8 lb) External battery pack 3 (0.12) 4 (0.16) 12.4 (0.49) 75 (2.95) Ø8 (0.31) Ø6.5 (0.26) h 189 (7.44) Ø12 (0.47) 20 (0.79) 10 (0.39) 44 (1.73) 4 (0.16) Grounding rings ØD 76.5 (3.01) 47 (1.85) 18.5 (0.73) Ød Dimensions in mm (inch) for grounding rings MAG 8000 with EPDM lining (7ME6810 and 7ME6820) DN 25 to DN 300 Dimension Internal diameter (d) Outside diameter (D) h DN 25 27 68 143 DN 40 38 88 163 DN 50 52 100 175 DN 65 64 120 195 DN 80 79 133 208 DN 100 95 158 233 DN 125 115 188 263 DN 150 145 216 291 DN 200 193 268 343 DN 250 246 324 399 DN 300 295 374 449 Dimensions in mm (inch), weight 2.0 kg (4.5 lb) Battery pack has to be mounted in upwards position to ensure maximum battery capacity. Siemens FI 01 · 2016 3/137 © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 Electrical installation of GSM/GPRS module ■ Schematics Electrical installation and pulse output – Connection diagram 2 91 92 93 94 95 Module interface (option) 3 1 087L4101 002900N423 HL 56 57 66 67 Output A Output B + 3.6 V DC 3 4 V 1 SIM card slot 2 GSM/GPRS antenna connector 3 Analog inputs inlet 4 Rechargeable battery inlet HL = Hardware lock key connection V = Push button for verification mode Pulse wire connection MAG 8000 External connection Internal connection Connection variant Passive output Open-Drain Output A 56 Positive logic < 50 mA + V 0V V ≤ 35 V DC Signal - 57 R Negative logic 66 Output B V 0V 67 V ≤ 35 V DC < 50 mA + - R Signal - The pulse output can be configured as volume, alarm or call-up. The output can be connected as positive or negative logic. R = pull up/down is selected in relation to the Vx power supply and with a max. current I of 50 mA. Use shielded cable to avoid EMC problems. Make sure the shield is correctly mounted under the cable clamp (no pig tail). 3/138 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 Accessories Description Article No. Description Article No. PC Flow Tool on CD (Download for free from www.siemens.com/flow) FDK:087L6001 One cable entry 2 ... 5 mm (0.08 ... 0.20 ") M12 brass glands with M20 reduction2) , package of 10 pcs, for GSM module antenna cable, power cable of external battery pack, encoder card cable FDK:087L4154 One cable entry 6 ... 8 mm (0.24 ... 0.31 ") M20 brass glands package2) (10 pcs), for pulse output cable or Modbus cable, Cello cable or mains power supply FDK:087L4155 One cable entry 8 ... 11 mm (0.31 ... 0.43 ") M20 brass glands package2) (10 pcs), for SOFREL cable FDK:087L4156 One cable entry 11 ... 15 mm (0.43 ... 0.59 ") M20 brass glands package2) (10 pcs) FDK:087L4157 Two cable entries 3.5 ... 5 mm (0.14 ... 0.20 ") M20 brass glands package2) (10 pcs) FDK:087L4158 Two cable entries 5.5 ... 7.5 mm (0.22 ... 0.30 "), M20 brass glands package2) (10 pcs) FDK:087L4159 IrDA infrared interface adapter with USB for data acquisition with 1.2 m (3.9 ft) cable FDK:087L4163 Battery backup for mains power supply, 1 pc. D-cell (3.6 V, 16.5 Ah)1) A5E03354392 Rechargeable Lithium bat- A5E03436686 tery for MAG 8000 GSM/GPRS communication module1) Internal battery pack, one FDK:087L4150 set of 2 D-cell (3.6 V, 33 Ah) and accessories for replacement1), incl. NBR O-ring External battery pack FDK:087L4151 IP68/NEMA 6P with connec1) tor, 4 D-cell (3.6 V, 66 Ah) . Order cable FDK:087L4152 separately. Mains power supply 12 ... 24 V AC/DC (average power consumption during line 0.1 VA) with battery backup and 3 m (9.8 ft) power cable for external connection (no battery included) Temperature range: Fixed laying: -40 ... +90 °C (-40 ... +194 °F) Flexible application: -30 ... +80 °C (-22 ... +176 °F) FDK:087L4210 3 High gain antenna for MAG 8000 GSM/GPRS (PVC, IP68, cable length 5 m (16.4 ft), with SMA male connector (type RG 58) and internal SMA to SMP female cable adapter, and single entry cable gland) A5E03436689 Analog input cable for MAG 8000 GSM/GPRS (3 m (9.8 ft) cable with M12 connector A-Coding female 5 pins, and two-entry cable gland) A5E03436698 Mains power supply FDK:087L4211 115 ... 230 V AC, 50/60 Hz, with battery backup up and 3 m (9.8 ft) power cable for external connection (no battery included) Potting kit for terminal box of FDK:085U0220 flow sensors for IP68/NEMA 6P RS 232 add-on module, point to point communication interface with Modbus RTU protocol FDK:087L4212 MAG 8000 Hardware key to FDK:087L4165 access protected parameters RS 485 add-on module, multidrop communication interface with Modbus RTU protocol FDK:087L4213 Encoder interface module, with "Sensus" protocol for ITRON 200WP and 100W radio A5E02475650 MAG 8000 GSM/GPRS communication module. Rechargeable battery, antenna and analog cable input must be ordered separately A5E03412758 MAG 8000 demo - training unit pack operating on Alkaline batteries. Transmitter with Flow tool CD, IrDA interface adapter and hardware key (No dangerous goods limitations) FDK:087L4080 Siemens FI 01 · 2016 3/139 © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 Description Article No. Description Article No. Alkaline battery for MAG 8000 demo transmitter (3 V 13 Ah) (No dangerous goods limitations) FDK:087L4142 MAG 8000 (Advanced version) transmitter remote replacement kit1). No battery included. No system number required. FDK:087L4204 MAG 8000 (Basic version) transmitter PCB replacement kit1). No system number required. A5E01171569 MAG 8000 (Advanced version) transmitter PCB replacement kit1). No system number required. FDK:087L4168 Enclosure top including plastic lid, screws, O-ring and blank product label FDK:087L4167 Power cable (1.5 m (4.9 ft)) with IP68/NEMA 6P plugs for external battery (no battery included); PE jacket, ambient temperature: -20 ... +60 °C (-4 ... +140 °F) FDK:087L4152 5 ft. Encoder interface cable with IP68/NEMA 6P plugs included, for ITRON 200WP and 100W radio; 22 AWG stranded TC conductors, polypropylene insulation, twisted pair, overall Beldfoil shield, 22 AWG stranded TC drain wire, PVC jacket A5E02551263 25 ft. Encoder interface cable with IP68/NEMA 6P plugs included, for ITRON 200WP radio; 22 AWG stranded TC conductors, polypropylene insulation, twisted pair, overall Beldfoil shield, 22 AWG stranded TC drain wire, PVC jacket A5E02551182 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. 1) Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and UN 3091". Special transport documentation is required to observe these regulations. This may influence both transport time and costs. 2) For cable connection through MAG 8000 transmitter bottom part. 3 When MAG 8000 (7ME6810 and 7ME6820) is installed in PVC or coated pipelines, grounding rings must be installed additionally. Grounding rings, type C must be used for the 7ME6810 and 7ME6820 routes (sizes > DN 300). Please see grounding rings in the section MAG 3100 Grounding rings and be aware that the mentioned MLFB codes include only 1 grounding ring. Grounding rings DN 25 to DN 300 in stainless steel are packed in pairs and sold as a “grounding ring kit”. Dimension Article No. DN 25 A5E01002946 DN 40 A5E01002947 DN 50 A5E01002948 DN 65 A5E01002950 DN 80 A5E01002952 DN 100 A5E01002953 DN 125 A5E01002954 DN 150 A5E01002955 DN 200 A5E01002957 DN 250 A5E01002958 DN 300 A5E01002962 Spare parts Description Article No. MAG 8000 transmitter compact replacement kit1). No battery included.With blank product label. System number specified by ordering. FDK:087L4166 MAG 8000 transmitter remote replacement kit1). No battery included. With blank product label. System number specified by ordering. FDK:087L4202 MAG 8000 (Advanced version) transmitter compact replacement kit1). No battery included. With blank product label. No system number required. FDK:087L4203 3/140 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M Battery-operated water meter MAG 8000 Description Article No. Service tool kit package with various component for service and replacement. Content: 10 plastic top lids 20 screws 10 wire holders 10 battery cups 10 greased O-rings 20 clamp kits 10 IrDA adaptor holding rings FDK:087L4162 MAG 8000 (7ME6880) grounding ring service kit, consisting of 2 pcs. grounding rings (AISI 304/1.4301), screws and gaskets Article No. Dimension 10 20 10 10 10 20 10 Remote cable set 5 m (16.4 ft) with IP68/NEMA 6P plugs - PG 13.52) FDK:087L4108 Remote cable set 5 m (16.4 ft) with IP68/NEMA 6P plugs - M20 A5E00862482 Remote cable set 10 m (32.8 ft) with IP68/NEMA 6P plugs - PG 13.52) FDK:087L4109 Remote cable set 10 m (32.8 ft) with IP68/NEMA 6P plugs - M20 A5E00862487 Remote cable set 20 m (65.6 ft) with IP68/NEMA 6P plugs - PG 13.52) FDK:087L4110 Remote cable set 20 m (65.6 ft) with IP68/NEMA 6P plugs - M20 A5E00862492 Remote cable set 30 m (98.4 ft) with IP68/NEMA 6P plugs - PG 13.52) FDK:087L4111 Remote cable set 30 m (98.4 ft) with IP68/NEMA 6P plugs - M20 A5E00862497 10 m cable set with premounted conduit adaptor A5E33400834 20 m cable set with premounted conduit adaptor A5E33400836 1) Not applicable to custody transfer (CT) verified systems without re-verification 2) For sensors produced before October 2007. Drilled pattern flanges (7 bar) DN 50 2" A5E03082907 DN 65 2½" A5E03082908 DN 80 3" A5E03082909 DN 100 4" A5E03082910 DN 125 5" A5E03082911 DN 150 6" A5E32877967 DN 200 8" A5E03082913 DN 250 10" A5E03082914 DN 300 12" A5E03082915 DN 350 14" A5E03082916 DN 400 16" A5E03082917 DN 450 18" A5E03082918 DN 500 20" A5E03082919 DN 600 24" A5E03082920 3 AS 2191 table E flanges DN 25 1" A5E33474999 DN 40 1½" A5E33475000 DN 125 5" A5E33475006 AS 4087 PN 16 flanges DN 50 2" A5E33475001 DN 65 2½" A5E33475002 DN 80 3" A5E33475003 DN 100 4" A5E33475004 DN 150 6" A5E33475007 DN 200 8" A5E33475008 DN 250 10" A5E33475009 DN 300 12" A5E33475010 DN 350 14" A5E33475011 DN 400 16" A5E33475012 DN 450 18" A5E34240921 DN 500 20" A5E33475013 DN 600 24" A5E33475014 DN 700 28" A5E33414889 DN 800 32" A5E33414890 DN 900 36" A5E33414891 DN 1000 40" A5E33414892 DN 1200 48" A5E33414893 Siemens FI 01 · 2016 3/141