MAG 8000 Catalog Specifications Sheet

© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
■ Overview
■ Application
The following MAG 8000 versions are available as stand-alone
water meters:
• MAG 8000 (7ME6810) for abstraction and distribution network
• MAG 8000 CT (7ME6820) for revenue and bulk metering
• MAG 8000 (7ME6880) for irrigation
■ Design
MAG 8000 is designed to minimize power consumption.
The product program consists of
• Basic and advanced version
• Sensor sizes from DN 25 to 1200 (1" to 48")
• Compact and remote installation in IP68/NEMA 6P enclosure
and factory-mounted cable
• SIMATIC PDM and Flow Tool PC configuration softwares
3
MAG 8000 is a comprehensive meter which intelligent information and high performance measurement as well as the easy to
install concept take cost of ownership and customer service to a
new level for water meter.
■ Benefits
Easy to install
• Compact or remote solution with factory mounted cable and
customer setting from factory
• IP68/NEMA 6P enclosure. Sensor can be buried
• Flexible power supply - internal or external battery pack or
mains power supply with battery back-up possibilities
• Superior measurement
• Down to 0.2 % maximum uncertainty
• OIML R 49 type approval
• PTB K7.2
• FM Fire Service Approval
• Bi-directional measurement
Long lasting performance/Low cost of Ownership
• Verification according to Directive 2014/32/EU of the
European Parliament and Council of 26 February, 2014 on
measuring instruments, Annex VI Thermal Energy Meters
(MI-004)
• No moving parts means less wear and tear
• Up to 6 to 10 years maintenance-free operation in typical revenue application
• Robust construction built for the application
Intelligent information, easy to access
• Advanced information on site
• Data logger
• Advanced statistics and diagnostics
• Add-on communication modules
3/116
Siemens FI 01 · 2016
Modbus/Encoder module
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
MAG 8000 GSM/GPRS Wireless Communication Module
The MAG 8000 GSM/GPRS wireless communication module
provides the latest mobile technology using a Quad Band
(850/900/1800/1900 MHz) module.
The GSM/GPRS module logs data from the MAG 8000 memory
and from the two analog inputs (one 4 to 20 mA not powered by
the module and one 5 V ratiometric powered by the module) and
storage in the internal memory and later transmit it into a system
or PC via email or SMS.
GSM/GPRS communication module
An additional synchronization function secures the initial collection time of the data independent of the sample rate used (minimum collection time: 1 per minute).
The package of information retrieved via the csv file includes:
• Time stamp
• Flow rate
• Tot 1
• Tot 2
• Tot 3
• Analog 1 (mA)
• Analog 2 (V)
• Battery lifetime
• Alarm list (as decimal format)
The GPRS technology makes it possible to send a higher
amount of data via email. The data is secured using a POP 3
server configuration avoiding encryptions that require additional
software. The configuration of the module is performed via SMS
commands that allow you to define the users, email accounts,
transmission settings, collection, etc.
PC-IrDA connection
The GSM/GPRS module is a compact built-in solution which can
be installed in the existing MAG 8000 with SW version 3.02 and
higher.
The battery lifetime will depend on signal strength and especially on the number of transmissions. Therefore we recommend
an optimal setting of transmission once a day (see page 3/121).
The module also includes the same power management algorithm that secures a very good calculation of the remaining battery lifetime.
The OPC server specifically designed for the MAG 8000
GSM/GPRS module is offered free of charge. With this valueadded package, the opportunity for measurement data collection and further processing/analyzing for system integration and
automation is offered.
Siemens FI 01 · 2016
3/117
3
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
■ Function
MAG 8000 is a microprocessor-based water meter with graphical display and key for optimum customer operation and information on site. The transmitter drives the magnetic field in the
sensor, evaluates the flow signal from the sensor and calculates
the volume passing through. It delivers the required information
via the integrated pulse output or communication interfaces as
part of a system solution. Its intelligent functionality, information
and diagnostics ensure optimum meter performance and information to optimize water supply and billing.
3
MAG 8000 can be ordered as a Basic or an Advanced version.
Features / Version
MAG 8000 Basic/
MAG 8000 Advanced
MAG 8000 Irrigation
Measuring frequency in 1/15, 1/30 or 1/60 Hz from 6.25 to 1/60 Hz
battery power mode
depending of sensor
(Manually selected)1)
size
Output MAG 8000
2 FW/RV/Al/CA (max. 2 FW/RV/Al/CA (max.
50 Hz pulse rate)
100 Hz pulse rate)
Communication
Add-on
Add-on
Data logger
Yes
Yes
Insulation test
No
Yes
Leakage detection
No
Yes
Meter utilization
No
Yes
Statistics
No
Yes
Tariff
No
Yes
Settle date (Revenue)
No
Yes
1)
Excitation frequency settings with mains power supply, see technical specifications for each version
Some information is accessible via the display whereas all information is accessible via the IrDA communication interface with
the PDM software. Data and parameters are registered in a
EEPROM. They can all be read, but changing the information demands a software password or a hardware key attached to the
printed circuit board.
3/118
Siemens FI 01 · 2016
The SIMATIC PDM tool gives the possibility of testing and verifying the flowmeter on site and creating a printed ”Qualification
Certificate” with all specific data that define the quality status of
the measurement.
The Qualification Certificate consists of two pages with information about the actual status of the sensor:
Part 1 provides general settings, sensor and battery info, totalizer values and pulse output settings.
Part 2 provides detailed information about electronic and sensor
functionality and a main parameter list for evaluating the functionality of the MAG 8000 water meter.
SIMATIC PDM
Details about the SIMATIC PDM tool can be found in chapter
"Communication and Software" (see page 8/9).
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
■ Technical specifications
Transmitter
Installation
Mains power supply
Compact (integral)
Remote with factory-mounted cable
5, 10, 20 or 30 m (16.4, 32.8, 65.6 or
98.4 ft)
Enclosure
Stainl. steel top housing (AISI 316) and
coated brass bottom.
Remote wall mount bracket in stainless steel (AISI 304).
Cable entries
2 x M20 (one gland for one cable of
size 6 … 8 mm (0.02 ... 0.026 ft) is
included in the standard delivery)
Display
Display with 8 digits for main information.
Index, menu and status symbols for
dedicated information
Resolution
Totalized information can be displayed with 1, 2 or 3 decimals or
automatic adjustment (default)
Flow unit
Europe
US
Australia
Volume: m3 x 100, l x 100, G x 100, G x
1000, MG, CF x 100, CF x 1000, AF, Al,
kl, BBL42
Flow: m3/min, m3/d, l/s, l/min, GPS,
GPH, GPD, MGD, CFS, CFM, CFH,
BBL42/s, BBL42/min, BBL42/h,
BBL42/d
Digital output
2 passive outputs (MOS), individual
galvanically isolated
Maximum load ± 35 V DC, 50 mA
short circuit protected
Programmable as pulse volume –
forward – reverse – forward/net –
reverse/net
Programmable as pulse volume (like
output A), alarm
Max. pulse rate of 50 Hz (only Basic
version) and 100 Hz (only Advanced
version), pulse width of
5, 10, 50, 100, 500 ms
Output B function
Output
Communication
Add-on modules
Power supply
Internal battery pack
External battery pack
3
Volume in m3 and flow rate in m3/h
Volume in Gallon and flow rate in
GPM
Volume in Ml and flow rate as Ml/d
Optional display units
Output A function
Cable
• 12 ... 24 V AC/DC (10 … 32 V) 2 VA
• 115 ... 230 V AC (85 … 264 V) 2 VA
Both mains power supply systems
are upgradable for battery backup
via internal D-Cell (3.6 V 16.5 Ah) or
external battery pack.
3 m (9.8 ft) for external connection to
mains supply (without cable plug)
IrDA: Standard integrated infrared
communication interface with Modbus RTU protocol
• RS 232 serial interface with Modbus
RTU (Rx/Tx/GND), point to point
with max. 15 m cable
• RS 485 serial interface with Modbus
RTU (+/-/GND), multidrop with up to
32 devices with max. 1000 m cable
• Encoder interface module (for Itron
200WP) "Sensus protocol"
• GSM/GPRS module with or without
analog input cable
Auto detection of power source with
display symbol for operation power.
1 D-Cell 3.6 V/16.5 Ah
2 D-Cell 3.6 V/33 Ah
4 D-Cell 3.6 V/66 Ah
Siemens FI 01 · 2016
3/119
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
Features
Application identification
Tag number up to 15 characters
Time and date
Real time clock
Totalizer
MAG 8000
3
3 totalizer: Configurable to
Forward, Reverse and Bidirectional
netflow
1 totalizer (following totalizer 1 setting) resetable via display key
Insulation test
(only Advanced version)
Test of signal immunity against disturbance and bad installation. Test
interval is selectable and measurement is interrupted during the test
period of 4 min.
Leakage detection
(only Advanced version)
Monitoring the lowest flow or volume
during selected time window within
24 hours. Leakage is detected over
a selectable period where monitored value exceed the possible
leakage level. Min and max values
are stored with date registration. Last
store value visible on the display.
Meter Utilization
(only Advanced version)
6 registers for monitoring total time
the meter has operated in different
flow intervals. Registered intervals
are free selectable as % of Qn (Q3)
Tariff
(only Advanced version)
6 tariff registers count the volume
delivered within the selected tariff
windows, based on time of day or
flow rates or a combination.
Tariff can also be used for consumption profile where consumption is
related to different time intervals or
flow rates.
Tariff values visible on the display.
Settling date
(only Advanced version)
On a predefined date the totalizer 1
index value is stored. Old values are
stored to show the latest two totalized 1 index values.
Settling values visible on the display.
Statistic
(only Advanced version)
Min. flow rate with time and date registration
Max. flow rate with time and date
registration
Min. daily consumption with date
registration
Max. daily consumption with date
registration
Latest 7 days total and daily consumption
Actual month consumption
Latest month consumption
PC Configuration Software
PDM
• Meter configuration – online and offline mode
• Own parameter settings
• Parameter documentation
• Print and export of data and parameters
PDM 6.0 Service Pack 2 – Basic and
Online version
Measurement
Low flow cut-off
• 7ME6810
0.05 % of Qmax (adjustable)
• 7ME6820
0.25 % of Q3
• 7ME6880
1 % of Qmax (adjustable)
Empty pipe detection
Symbolised in display
Data logger
Logging of 26 records: selectable as
daily, weekly or monthly logging
Alarm
Active alarm is indicated on the display
Data protection
All data stored in an EEPROM. Totalizers 1 and 2 are backed up every
10 min, statistic every hour and
power consumption and temperature
measurement every 4 hour.
Password protection of all parameters and hardware protection of calibration and revenue parameters.
Battery power management
Optimal battery information on
remaining capacity.
Calculated capacity includes all consuming elements and available battery capacity is adjusted related to
change in ambient temperature.
Numbers of power-ups
Date and time registered for first and
last time power alarm.
Diagnostic
Continuous self test including
Alarm statistics and logging for
fault analyzing
3/120
Siemens FI 01 · 2016
Coil current to drive the magnetic
field
Signal input circuit
Data calculation, handling and storing
Electrode impedance to check
actual media contact
Flow simulation to check pulse and
communication signal chain for correct scaling
Number of sensor measurements
(excitations)
Transmitter temperature (battery
capacity calculation)
Low impedance alarm for change in
media
Flow alarm when defined high flow
exceeds
Verification mode for fast measure
performance check
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
MAG 8000 water meter uncertainty
To ensure continuous accurate measurement, flowmeters must
be calibrated. The calibration is conducted at Siemens flow facilities with traceable instruments referring directly to the physical unit of measurement according to the International System of
Units (SI).
Therefore, the calibration certificate ensures recognition of the
test results worldwide, including the US (NIST traceability).
Siemens offers accredited calibrations assured to ISO 17025 in
the flow range from 0.0001 m3/h to 10 000 m3/h.
Siemens Flow Instruments accredited laboratories are recognized by ILAC MRA (International Laboratory Accreditation Corporation - Mutual Recognition Arrangement) ensuring international traceability and recognition of the test results worldwide.
Grounding
The sensor body must be grounded using grounding straps
and/or grounding rings to protect the flow signal against stray
electrical noise. This ensures that the noise is carried through the
sensor body and a noise-free measuring area within the sensor
body. For MAG 8000 Irrigation grounding rings on both sides are
factory-mounted.
Metal pipes
M6 x 16
On metal pipes, connect the straps
to both flanges.
3
Metal pipe
Metal pipe
The selected calibration determines the accuracy of the meter.
A standard calibration results in max.  0.4 % uncertainty and an
extended calibration  0.2 % (for MAG 8000 irrigation ± 0.8 %).
A calibration certificate follows every sensor and calibration data
are stored in the meter unit.
Plastic pipes
On plastic pipes and lined metal
pipes, optional grounding rings must
be used at both ends.
Grounding rings has to be ordered
separately see „Grounding ring kit“
± E%
1.2
Plastic pipe
Error
Plastic pipe
Standard calibration (7ME688)
E=± 0.8 % of rate ± 2.5 mm/s
1.0
0.8
0.6
Standard calibration (7ME681)
E=± 0.4 % of rate ± 2 mm/s
0.4
Combination of metal and
plastic pipes
M6 x 16
A combination of metal and plastic
requires straps for metal pipe and
grounding rings for plastic pipe.
Extended calibration(7ME681)
E=± 0.2 % of rate ± 2 mm/s
0.2
0.0
0
2
4
6
8
10
12 m/s
Flowrate
Metal pipe
Plastic pipe
MAG 8000 (7ME6810) for Fire Service applications
MAG 8000 (7ME6810) is FM Fire Service approved for automatic
fire protection systems according to the Fire Service Meters
Standard, Class Number 1044. The approval is applicable for
the sizes DN 50, DN 80, DN 100, DN 150, DN 200, DN 250, and
DN 300 (2", 3", 4", 6", 8", 10", and 12") with ANSI B16.5 Class 150
flanges. The FM Fire Service approved product can be ordered
via the Z-options P20, P21 and P22
Battery operation time and calculation
The battery operation time depends on the connected battery
pack as well as the operation condition of the meter.
MAG 8000 calculates the remaining capacity every 4 hours and
includes all consuming elements. Calculation compensates for
temperature influence on battery capacity.
±E%
20
1.5 %
Qmin
Capacity to 2 Volts/Ah
FM Fire Service verification tolerances
Available capacity
0.6 mA
15
10
Qmax
0
-50 -35 -20 -5 10 25 40 55 70 85 100
(-58) (-31) (-4) (23) (50) (77) (104) (131)(158)(185) (212)
Temperature °C (°F)
The graphic shows the effect from other temperatures.
A variation in temperature from 15 °C to 55 °C (59 to 131 °F)
reduces the capacity by 17 % from 15 Ah to 12.5 Ah.
At typical revenue scenario of expected battery operation time
can be seen in the table below.
The measurement for calculating the rest capacity of the battery
life time is only completed if the system has no active fatal faults
or the empty pipe is active. Maximum battery specification is
10 years operation.
Siemens FI 01 · 2016
3/121
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
Scenario - Revenue application
3
Output A
Pulse rate max. 10 Hz
Output B
Alarm or call-up
Meter dialog
1 hour per month
Add-com
None
Temperature
• 5 % at 0 °C (32 °F)
• 80 % at 15 °C (59 °F)
• 15 % at 50 °C (122 °F)
Battery lifetime (subject to the assumptions mentioned above)
MAG 8000 for abstraction and distribution network applications (7ME6810) and MAG 8000 CT for revenue and bulk metering (7ME6820)
Excitation frequency (24 h operation)
1/60 Hz
1/30 Hz
1/15 Hz
1/5 Hz
1.5625 Hz
3.125 Hz
6.25 Hz
2 D-Cell battery 33 Ah
Internal battery pack
DN 25 ... 200
(1" ... 8")
8 years
8 years
6 years
40 months
8 months
4 months
2 months
DN 250 … 600
(10" ... 24")
8 years
6 years
4 years
20 months
4 months
2 months
N/A
DN 700 ... 1 200
(28" ... 48")
6 years
4 years
2 years
1 year
2 months
N/A
N/A
DN 25 ... 200
(1" ... 8")
N/A
10 years
10 years
80 months
16 months
8 months
4 months
DN 250 ... 600
(10" ... 24")
N/A
10 years
8 years
40 months
8 months
4 months
N/A
DN 700 ... 1 200
(28" ... 48")
10 years
8 years
4 years
2 years
4 months
N/A
N/A
4 D-Cell battery 66 Ah
External battery pack
MAG 8000 for irrigation applications (7ME6880)
Excitation frequency (24 h operation)
1/60 Hz
1/30 Hz
1/15 Hz
1/5 Hz
1.5625 Hz
3.125 Hz
1 D-Cell battery
Internal battery pack
DN 25 ... 600 (1" ... 24")
52 months
40 months
25 months
12 months
2 months
1 month
DN 700 ... 1 200 (28" ... 48")
3 years
2 years
1 years
6 months
1 month
N/A
2 D-Cell battery 33 Ah
Internal battery pack
DN 50 … 600 (2" ... 24")
8 years
80 months
50 months
24 months
4 months
2 months
DN 700 ... 1 200 (28" ... 48")
6 years
4 years
2 years
1 year
2 months
N/A
4 D-Cell battery 66 Ah
External battery pack
DN 50 ... 600 (2" ... 24")
10 years
10 years
8 years
48 months
8 months
4 months
DN 700 ... 1 200 (28" ... 48")
10 years
8 years
4 years
2 years
4 months
N/A
MAG 8000 GSM/GPRS battery lifetime scenario
Transmission once a day and MAG 8000 factory settings
2 D-Cell battery 33 Ah Internal battery pack
3 years
4 D-Cell battery 66 Ah External battery pack
7 years
External battery pack can be used as battery backup for mains
power supply (if two cable entries in one cable gland are
needed, order cable glands with two entries, see accessories on
page 3/139).
Serial RS 232/RS 485 add-on communication modules are designed for mains powered systems as the battery operation time
will be reduced. At 1 hour communication per month (all meter
data collected 2 times per day) and the module is connected,
the operation time is reduced to:
• RS 232:
- low excitation frequency: 10 % of calculated operation time
- high excitation frequency: 80 % of calculated operation time
• RS 485:
- low excitation frequency: 50 % of calculated operation time
- high excitation frequency: 90 % of calculated operation time
3/122
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 for abstraction and distribution network applications (7ME6810)
■ Overview
■ Technical specifications
Meter
Accuracy
Standard calibration:
± 0.4 % of rate ± 2 mm/s
Extended calibration
DN 50 ... DN 300 (2" ... 12"):
± 0.2 % of rate ± 2 mm/s
Low flow cut-off (default)
0.05 %
Media conductivity
Clean water > 20 s/cm
Temperature
Ambient
-20 ... +60 °C (-4 ... +140 °F)
Media
0 ... 70 °C (32 ... 158 °F)
Storage
-40 ... +70 °C (-40 ... +158 °F)
Enclosure rating
Remote sensor
IP68 to EN 60529/NEMA 6P,
10 mH2O cont.
Compact version
IP68 to EN 60529/NEMA 6P,
3 mH2O for six months
Certificates and approvals
Calibration
• Standard calibration
• Special calibration
■ Benefits
Easy to install
• Compact or remote solution with factory mounted cable
• IP68/NEMA 6P enclosure. Sensor can be buried.
• Flexible power supply - internal or external battery pack or
mains power supply with battery back-up possibilities
Long-term stability/Low cost of ownership
• No moving parts in a robust construction means less wear and
tear
• Basic and advanced transmitter versions with different optional add-on communication modules fulfil various customer
requirements for high cost efficiency
• Up to 0.2 % maximum uncertainty
• Bi-directional measurement with an outstanding low flow performance
• Up to 10 years maintenance-free operation in typical applications
Intelligent information, easy to access
• Advanced information on site
• Advanced statistics and diagnostics
• Optional high-performance GSM/GPRS module offers an efficient solution for remote measurement and monitor via wireless communication.
Material certificate EN 10204-3.1
Drinking water approvals
Fire Service Approvals
Conformity
2 x 25 % and 2 x 90 % (default)
5-point calibration: 20 %, 40 %,
60 %, 80 %, 100 % of factory Qmax
10-point calibration: ascending and
descending at 20 %, 40 %, 60 %,
80 %, 100 % of factory Qmax
Matched-pair calibration: default,
5-point, 10-point
Available when ordering together
with meter1)
• NSF/ANSI Standard 612) (cold
water) USA
• WRAS (BS 6920 cold water) UK
• ACS Listed France
• DVGW W270 Germany
• Belgaqua (B)
• MCERTS (GB)
FM Fire Service Meter
(Class Number 1044)3)
• PED: 97/23EC4)
For pressure/temperature curves
see MAG 3100 on page 3/70.
• EMC: IEC/EN 61326
Sensor version
DN 25 … 1200 (1" … 48")
Sensor material
Carbon steel ASTM A 105, with corrosion resistant two-component
epoxy coating (150 m/300 m)
Corrosivity category C4, according
to ISO 12944-2
Measuring principle
Electromagnetic induction
Excitation frequency
Basic version
• Battery-powered
DN 25 ... 150 (1” ... 6”): 1/15 Hz
DN 200 … 600 (8” … 24”): 1/30 Hz
DN 700 ... 1200 (28“ ... 48“):
1/60 Hz
• Mains-powered
DN 25 ... 150 (1” ... 6”): 6.25 Hz
DN 200 … 600 (8” … 24”):
3.125 Hz
DN 700 ... 1200 (28“ ... 48“):
1.5625 Hz
Siemens FI 01 · 2016
3/123
3
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 for abstraction and distribution network applications (7ME6810)
Advanced version
3
• Battery-powered
DN 25 ... 150 (1” ... 6”): 1/15 Hz
(adjustable up to 6.25 Hz; reduced
battery lifetime)
DN 200 … 600 (8” … 24”): 1/30 Hz
(adjustable up to 3.125 Hz;
reduced battery lifetime)
DN 700 ... 1200 (28“ ... 48“):
1/60 Hz
(adjustable up to 1.5625 Hz;
reduced battery lifetime)
• Mains-powered
DN 25 ... 150 (1” ... 6”): 6.25 Hz
DN 200 … 600 (8” … 24”):
3.125 Hz
DN 700 ... 1200 (28“ ... 48“):
1.5625 Hz
Flanges
EN 1092-1 (DIN 2501)
DN 25 and DN 40 (1" and 1½"):
PN 40 (580 psi)
DN 50 … 150 (2" … 6"):
PN 16 (232 psi)
DN 200 … 1200 (8" … 48"):
PN 10 or PN 16 (145 psi or 232 psi)
ANSI 16.5 Class 150
1” … 24”: 20 bar (290 psi)
AWWA C-207
28" … 48": PN 10 (145 psi)
AS 4087
DN 50 … 1200 (2" … 48"): PN 16
(232 psi)
Liner
EPDM
Electrode and grounding
electrodes
Hastelloy C276/2.4819
Grounding straps
Grounding straps are premounted
from the factory on each side of the
sensor.
1)
Has to be ordered with the meter. It is not possible to order the certificate
afterwards.
2)
Including Annex G
3)
Not for sensors with 300 m coating.
4)
For further information on the PED standard and requirements see page 9/6.
3/124
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 for abstraction and distribution network applications (7ME6810)
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS F M MAG 8000 water meter
7 ME 6 8 1 0 77777 - 7777
SITRANS F M MAG 8000 water meter
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
 2D
 2R
 2Y
DN 65 (2½“)
DN 80 (3“)
DN 100 (4“)
 3F
 3M
 3T
DN 125 (5“)
DN 150 (6“)
DN 200 (8“)
 4B
 4H
 4P
DN 250 (10“)
DN 300 (12“)
DN 350 (14“)
 4V
 5D
5K
DN 400 (16“)
DN 450 (18“)
DN 500 (20“)
DN 600 (24“)
5R
5Y
6F
6P
DN 700 (28“)1)
DN 750 (30“)1)
DN 800 (32“)1)
DN 900 (36“)1)
DN 1000 (40“)1)
6Y
7D
7H
7M
Flange norm and pressure rating
EN 1092-1
PN 10 (DN 200 ... 1200 (8" ... 48"))
PN 16 (DN 50 ... 1200 (2" ... 48"))
PN 16 non-PED (DN 700 .... 1200 ( 28"... 48"))
PN 40 (DN 25 ... 40 (1" ... 1½“))
ANSI B16.5
Class 150
AWWA C-207
Class D (28" ... 48")
AS4087
PN 16 (DN 50 ... 1200 (2" ... 48"))
Sensor version
EPDM liner and Hastelloy electrodes, 150 m
coating
EPDM liner and Hastelloy electrodes , 300 m
coating
No additional "add-on" communication module
installed
Serial RS 485 with Modbus RTU
(Terminated as end device)
Serial RS 232 with Modbus RTU
Encoder interface with Sensus protocol
GSM/GPRS communication module with remote
antenna; 5 m (16.4 ft) cable
GSM/GPRS communication module with analog
inputs and remote antenna; 5 m (16.4 ft) cable

3
A
B
C
D
S
T



0
1
2
12/24 V AC/DC power supply with battery backup
and 3 m (9.8 ft) power cable for external connection (no battery included)
115 ... 230 V AC power supply with battery backup 
and 3 m (9.8 ft) power cable for external connection (no battery included)
3
Internal battery (no battery included)
Internal battery pack installed2)
Power cable (1.5 m (4.9 ft)) with IP68/NEMA 6P
plugs for external battery (no battery included)
1)
B
C
D
F
4
The Diameter DN 700 (28") to DN 1200 (48") is only available as remote
transmitter type installation.
Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and
UN 3091". Special transport documentation is required to observe these
regulations. This may influence both transport time and costs.
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Operating instructions for SITRANS F M MAG 8000
J
L
N

3

4
Description
Article No.
• English
A5E03071515
• German
A5E00740986
This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Operating instructions for MAG 8000 GSM/GPRS communication module
Calibration
Standard ± 0.4 % of rate ± 2 mm/s
Extended ± 0.2 % of rate ± 2 mm/s DN 50... 300
(2" ... 12")

Power supply
2)

L
M
N
P
Communication interface
7R
7U
7V
8B
DN 1050 (42“)1)
DN 1100 (44“)1)
DN 1200 (48“)1)
7 ME 6 8 1 0 77777 - 7777
Advanced version, remote cables mounted on sensor with IP68/NEMA 6P plugs:
• 5 m (16.4 ft)
• 10 m (32.8 ft)
• 20 m (65.6 ft)
• 30 m (98.4 ft)
Diameter
DN 25 (1“)
DN 40 (1½“)
DN 50 (2“)
Article No.

1
2
Description
Article No.
• English
A5E03644134
Region version
Europe (m3, m3/h, 50 Hz)
USA (Gallon, GPM, 60 Hz)
Australia (Ml, Ml/d, 50 Hz)
1
2
3
Transmitter type and installation
Basic version integral on sensor
Basic version, remote cables mounted on sensor
with IP68/NEMA 6P plugs:
• 5 m (16.4 ft)
• 10 m (32.8 ft)
• 20 m (65.6 ft)
• 30 m (98.4 ft)
Advanced version integral on sensor


A
B
C
D
E
K
Siemens FI 01 · 2016
3/125
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 for abstraction and distribution network applications (7ME6810)
Selection and Ordering data
Order code
Additional information
Please add “-Z“ to Article No. and specify Order
code(s) and plain text.
Please add “-Z“ to Article No. and specify Order
code(s) and plain text.
Certificate
Material certificate according to EN 10204-3.1
C121)
Special calibration
3
Selection and Ordering data
Additional information
5-point calibration for DN 15 ... DN 2002)
5-point calibration for DN 250 ... DN 6002)
5-point calibration for DN 700 ... DN 12002)
D01
D02
D03
10-point calibration for DN 15 ... DN 2003)
10-point calibration for DN 250 ... DN 6003)
10-point calibration for DN 700 ... DN 12003)
D06
D07
D08
Default (2 x 25 % and 2 x 90 %) match-pair calibration
for DN 15 ... DN 200
Default (2 x 25 % and 2 x 90 %) match-pair calibration
for DN 250 ... DN 600
Default (2 x 25 % and 2 x 90 %) match-pair calibration
for DN 700 ... DN 1200
D11
5-point, matched-pair calibration for
DN 15 ... DN 2002)
5-point, matched-pair calibration for
DN 250 ... DN 6002)
5-point, matched-pair calibration for
DN 700 ... DN 12002)
D15
10-point, matched-pair calibration for
DN 15 ... DN 2003)
10-point, matched-pair calibration for
DN 250 ... DN 6003)
10-point, matched-pair calibration for
DN 700 ... DN 1200 3)
D18
D12
D13
D16
D17
D19
D20
Flow unit
l/s
MGD
CFS
L00
L01
L02
l/min
m3/min
GPM
L03
L04
L05
CFM
l/h
m3/h
L06
L07
L08
GPH
CFH
GPS
L09
L10
L11
Ml/d
m3/d
GPD
L12
L13
L14
BBL42/s
BBL42/min
BBL42/h
BBL42/d
L15
L16
L17
L18
Totalizer
Volume calculation (default totalizer 1= forward and
totalizer 2 = reverse)
Totalizer 1 = RV, reverse flow
Totalizer 1 = NET, net flow
Totalizer 2 = FW, forward flow
Totalizer 2 = NET, net flow
L20
L22
L30
L31
Volume unit
m3
Ml
G
L40
L41
L42
AF
l x 100
m3 x 100
L43
L44
L45
3/126
Siemens FI 01 · 2016
Order code
G x 100
CF x 100
MG
L46
L47
L48
G x 1000
CF x 1000
AI
L49
L50
L51
kI
BBL42 (US oil barrel, 1 barrel = 42 US gallons)
L52
L54
Pulse set up
(default pulse A = forward and pulse B = Alarm, pulse
width = 50 ms)
A function = RV, reverse flow
A function = FWnet, forward net flow
A function = RVnet, reverse net flow
A function = Off
L62
L63
L64
L65
Volume per pulse A = x 0.00014)
Volume per pulse A = x 0.0014)
Volume per pulse A = x 0.014)
Volume per pulse A = x 0.14)
Volume per pulse A = x 14)
L70
L71
L72
L73
L74
B function = FW, forward flow
B function = RV, verse flow
B function = FWnet, forward net flow
L80
L81
L82
B function = RVnet, reverse net flow
B function = Alarm
B function = Call up
L83
L84
L85
Volume per pulse B = x 0.00014)
Volume per pulse B = x 0.0014)
Volume per pulse B = x 0.014)
L90
L91
L92
Volume per pulse B = x 0.14)
Volume per pulse B = x 14)
L93
L94
Data logger set up (default month logging)
DataloggerInterval = Daily
DataloggerInterval = Weekly
M31
M32
Factory mounted cables
5 m (16.4 ft) pulse cable A+B
5 m (16.4 ft) communication cable RS 232/RS 485
terminated as end device
M81
M82
20 m (65.6 ft) pulse cable A+B
20 m (65.6 ft) communication cable RS 232/RS 485
terminated as end device
Cello 2 channel, input cable 3 m (9.84 ft) with
Brad Harrison micro-change 3 way connector
Cello 2 channel, input cable 5 m (16.4 ft) with
MIL-C-26482 spec. connectors
Encoder interface cable with connector for ITRON
200WP radio, lenght 25 ft
Encoder interface cable with connector for ITRON
200WP radio, length 5 ft
SOFREL data logger cable 2 m with connector for
SOFREL GSM module
M84
M85
FM Fire Service Approval
(with ANSI B16.5 Class 150 flanges)
DN 50, DN 80 and DN 100 (2“, 3" and 4")
DN 150 and DN 200 (6" and 8")
DN 250 and DN 300 (10" and 12")
M87
M89
M90
M91
M92
P20
P21
P22
1)
Under preparation
2)
20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax
3)
Ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory
Qmax
4)
Pulse width = 10 ms
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 CT for revenue and bulk metering (7ME6820)
■ Overview
■ Technical specifications
Meter
Accuracy
OIML R 49/OIML R 49 MAA for
DN 50 ... DN 300 (2" ... 12"),
Class I and II with turn down up to
Q3/Q1 = 400 at Q2/Q1 =1.6
MI-001 verification for
DN 50 … DN 600 (2" ... 24"),
Class II with turn down ratio Q3/Q1
= 250, Q3/Q1 = 200 or Q3/Q1 =
160 at Q2/Q1 = 1.6
FM Fire Service for
DN 50, DN 80, DN 100, DN 150,
DN 200, DN 250, and DN 300 (2",
3", 4", 6", 8", 10", and 12")
 1.5% (Qmin to Qmax)
Low flow cut-off (default)
0.25 %
Media conductivity
Clean water > 20 s/cm
Temperature
Ambient
-20 ... +60 °C (-4 ... +140 °F)
MI-001: -25 ... +55 ºC
(-13 ... +131 ºF)
Media
0.1 ... 50 °C (32 ... 122 °F)
Storage
-40 ... +70 °C (-22 ... +158 °F)
■ Benefits
Approvals
• MI-001, OIML R 49/OIML R 49 MAA
• PTB K7.2
• FM Fire Service
Easy to install
• Compact or remote solution with factory mounted cable and
customer setting from factory
• IP68/NEMA 6P enclosure. Sensor can be buried
• Flexible power supply - internal or external battery pack or
mains power supply with battery back-up possibilities
Long-term stability/Low cost of ownership
• No moving parts in a robust construction means less wear and
tear
• Basic and advanced transmitter versions with different optional add-on communication modules fulfil various customer
requirements for high cost efficiency
• Bi-directional measurement with an outstanding low flow performance
• Up to 10 years maintenance-free operation in typical applications
• Insignificant pressure drop
Enclosure rating
Remote sensor
IP68 to EN 60529/NEMA 6P,
10 mH2O cont.
Compact version
IP68 to EN 60529/NEMA 6P,
3 mH2O for six months
Certificates and approvals
Calibration (standard)
Material certificate EN 10204 3.1
2 x 25 % and 2 x 90 %
Available when ordering together
with meter1)
Drinking water approvals
• NSF/ANSI Standard 612) (cold
water) USA
• WRAS (BS 6920 cold water) UK
• ACS Listed France
• DVGW W270 Germany
• Belgaqua (B)
• MCERTS (GB)
Fire Service approval
FM Fire Service (1044)3)
Custody transfer approval
• OIML R 49 and OIML R 49 MAA
approval (DN 50 ... DN 300
(2" ... 12"))
• MI-001 approval
(DN 50 ... DN 600 (2" ... 24"))
(DK-0200-MI-001-011)
• PTB K7.2
Conformity
• CEN EN 14154, ISO 4064
• PED: 2014/68/EU4)
For pressure/temperature curves,
see MAG 3100 on page 3/70.
• EMC: IEC/EN 61326
Sensor version
DN 50 ... 600 (2" ... 24")
Sensor material
Carbon steel ASTM A 105, with
corrosion resistant two-component
epoxy coating (150 m/300 m)
Corrosivity category C4, according
to ISO 12944-2
Measuring principle
Electromagnetic induction
Intelligent information, easy to access
• Advanced information on site
• Advanced statistics and diagnostics
• Connectable to common AMR systems
Excitation frequency
Basic version
• Battery-powered
• Mains-powered
DN 50 ... 150 (2” ... 6”): 1/15 Hz
DN 200 … 600 (8” … 24”): 1/30 Hz
DN 50 ... 150 (2” ... 6”): 6.25 Hz
DN 200 … 600 (8” … 24”): 3.125 Hz
Siemens FI 01 · 2016
3/127
3
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 CT for revenue and bulk metering (7ME6820)
Advanced version
• Battery-powered
DN 50 ... 150 (2” ... 6”): 1/15 Hz
(adjustable up to 6.25 Hz; reduced
battery lifetime)
DN 200 … 600 (8” … 24”): 1/30 Hz
(adjustable up to 3.125 Hz;
reduced battery lifetime)
DN 50 ... 150 (2” ... 6”): 6.25 Hz
DN 200 … 600 (8” … 24”): 3.125 Hz
• Mains-powered
Flanges
EN 1092-1 (DIN 2501)
1)
Has to be ordered with the meter. It is not possible to order the certificate
afterwards.
2)
Including Annex G
3)
Not for sensors with 300 m coating.
4)
For further information on the PED standard and requirements see page 9/6.
DN 50 … 150 (2" … 6"):
PN 16 (232 psi)
DN 200 … 300 (8" … 12"):
PN 10 or PN 16
(145 psi or 232 psi)
up to DN 600 (24") in preparation
2” … 12”: 20 bar (290 psi)
up to DN 600 (24") in preparation
28" … 48": PN 10 (145 psi)
DN 50 … 300 (2" … 12"):
PN 16 (232 psi)
up to DN 600 (24") in preparation
3
ANSI 16.5 Class 150
AWWA C-207
AS 4087
Liner
EPDM
Electrode and grounding
electrodes
Hastelloy C276/2.4819
Grounding straps
Grounding straps are premounted
from the factory on each side of the
sensor
MAG 8000 CT (Revenue program) water meter type approval
MAG 8000 CT program is type approved and verified according to international water meter standard OIML R 49.
The custody transfer program is approved as Class I and Class II, for the sensor program from DN 50 to DN 300, at different Q3 and
Q3/Q1. Q2/Q1 = 1.6 and follows OIML R 49 specification.
±E%
Cl. II = 5%
Cl. I = 3%
Cl. II = 2%
Cl. I = 1%
Q1 Q2
Q3
Cl. I / Cl. II = OIML R 49 Class I / Class II
Q4
OIML R 49/2006-DK2-10.01 Revision 1 approval specification for Class I (1 %)1)
Size
DN 50
(2“)
DN 65
(2½“)
DN 80
(3“)
DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600
(4“)
(5“)
(6“)
(8“)
(10“)
(12“)
(14“)
(16“)
(18“)
(20“)
(24“)
„R“ Q3/Q1
250
250
250
250
250
250
250
250
125
-
-
-
-
-
Q1 [m3/h]
0.25
0.40
0.63
1.00
160
2.50
4.00
6.40
12.8
-
-
-
-
-
Q2 [m3/h]
0.40
0.64
1.00
1.60
2.60
4.00
6.40
10.24
20.48
-
-
-
-
-
Q3 [m3/h]
63
100
160
250
400
630
1000
1600
1600
-
-
-
-
-
Q4 [m3/h]
78.75
125
200
312.5
500
787.5
1250
2000
2000
-
-
-
-
-
OIML R 49/2006-DK2-10.01 Revision 1 approval specification for Class II (2
%)1)
Size
DN 50
(2“)
DN 65
(2½“)
DN 80
(3“)
DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600
(4“)
(5“)
(6“)
(8“)
(10“)
(12“)
(14“)
(16“)
(18“)
(20“)
(24“)
„R“ Q3/Q1
400
400
400
400
400
400
400
400
200
-
-
-
-
-
Q1 [m3/h]
0.16
0.25
0.40
0.63
1.00
1.60
2.50
4.00
10.00
-
-
-
-
-
Q2 [m3/h]
0.25
0.40
0.63
1.00
1.60
2.50
4.00
6.40
16.00
-
-
-
-
-
Q3 [m3/h]
63
100
160
250
400
630
1000
1600
1600
-
-
-
-
-
Q4 [m3/h]
78.75
125
200
312.5
500
787.5
1250
2000
2000
-
-
-
-
-
1)
The product will be delivered according to requested specifications, which may deviate from the specifications of the approval frame described in tables
below.
3/128
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 CT for revenue and bulk metering (7ME6820)
MAG 8000 CT (Revenue program) MI-001
MAG 8000 CT program is type approved according to international water meter standard OIML R 49. Since the first November 2006
the MI-001 water meter directive is in force, which means that all water meters can be sold across the EU borders if the water meters
contain a MI-001 label.
The MAG 8000 CT MI-001 verified and labeled products are a Class II aproval according to Directive 2014/32/EU of the
European Parliament and Council of 26 February, 2014 on measuring instruments, Annex VI Thermal Energy Meters (MI-004) in the sizes
from DN 50 to DN 400.
The MID certification is obtained as a B + D module approval according to the above mentioned directive.
Module B : Type approval according to OIML R 49
Module D : Quality insurance approval of production
3
MI-001 verification tolerances
±E%
Cl. II = 5%
Cl. II = 2%
Q1 Q2
Q3
Q4
MAG 8000 CT MI-001 verified and labeled products at a given Q3 and Q4/Q3 = 1.25 and Q2/Q1 = 1.6 measuring ranges see below table:
7ME6820xxxx1
DN 50
(2“)
DN 65
(2½“)
DN 80
(3“)
DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600
(4“)
(5“)
(6“)
(8“)
(10“)
(12“)
(14“)
(16“)
(18“)
(20“)
(24“)
„R“ Q3/Q1
25
25
25
25
25
25
25
25
25
25
25
25
25
25
Q4 [m3/h]
20
31.25
50
78.75
125
200
312.5
500
787.5
1250
1250
1250
2000
3125
[m3/h]
Q3
16
25
40
63
100
160
250
400
630
1000
1000
1000
1600
2500
Q2 [m3/h]
0.96
1.60
2.60
4.03
6.40
10.24
16
25.60
40.3
64
64
64
102.4
160
Q1 [m3/h]
0.60
1
1.60
2.52
4
6.40
10
16
25.2
40
40
40
64
100
7ME6820xxxx2
DN 50
(2“)
DN 65
(2½“)
DN 80
(3“)
DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600
(4“)
(5“)
(6“)
(8“)
(10“)
(12“)
(14“)
(16“)
(18“)
(20“)
(24“)
„R“ Q3/Q1
63
63
63
63
63
63
63
63
63
63
63
63
63
63
Q4 [m3/h]
20
31.25
50
78.75
125
200
312.5
500
750
1250
1250
3125
3125
5000
Q3 [m3/h]
16
25
40
63
100
160
250
400
630
1000
1000
2500
2500
4000
Q2 [m3/h]
0.41
0.63
1.02
1.60
2.54
4.06
6.35
10.16
16
25.4
25.4
63.49
63.49
101.6
[m3/h]
0.25
0.40
0.63
1
1.59
2.54
3.97
6.35
10
15.9
15.9
39.68
39.68
63.49
7ME6820xxxx3
DN 50
(2“)
DN 65
(2½“)
DN 80
(3“)
DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600
(4“)
(5“)
(6“)
(8“)
(10“)
(12“)
(14“)
(16“)
(18“)
(20“)
(24“)
„R“ Q3/Q1
80
80
80
80
80
80
80
80
80
80
80
80
80
80
[m3/h]
20
31.25
50
78.75
125
200
312.5
500
1250
2000
2000
5000
5000
7875
Q3 [m3/h]
16
25
40
63
100
160
250
400
1000
1600
1600
4000
4000
6300
Q2 [m3/h]
0.32
0.50
0.80
1.20
2
3.20
5
8
20
32
32
80
80
126
Q1 [m3/h]
0.20
0.31
0.50
0.75
1.25
2
3.13
5
12.50
20
20
50
50
78.75
7ME6820xxxx4
DN 50
(2“)
DN 65
(2½“)
DN 80
(3“)
DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600
(4“)
(5“)
(6“)
(8“)
(10“)
(12“)
(14“)
(16“)
(18“)
(20“)
(24“)
„R“ Q3/Q1
160
160
160
160
Q1
Q4
160
160
160
160
160
-
-
-
-
-
2000
-
-
-
-
-
-
-
-
-
Q4
[m3/h]
Q3
[m3/h]
40
63
100
160
250
400
630
1000
1600
-
Q2
[m3/h]
0.40
0.63
1
1.60
2.50
4
6.30
10
16
-
-
-
-
-
Q1 [m3/h]
0.25
0.39
0.63
1
1.56
2.50
3.94
6.25
10
-
-
-
-
-
7ME6820xxxx5
DN 50
(2“)
DN 65
(2½“)
DN 80
(3“)
DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600
(4“)
(5“)
(6“)
(8“)
(10“)
(12“)
(14“)
(16“)
(18“)
(20“)
(24“)
„R“ Q3/Q1
200
200
200
200
200
200
200
200
200
-
-
-
-
-
Q4 [m3/h]
50
78.75
125
200
312.5
500
787.5
1250
2000
-
-
-
-
-
Q3 [m3/h]
40
63
100
160
250
400
630
1000
1600
-
-
-
-
-
8
12.8
-
-
-
-
-
5
8
-
-
-
-
-
Q2
[m3/h]
Q1
[m3/h]
50
0.32
0.20
78.75
0.50
0.32
125
0.80
0.50
200
1.28
0.80
312.5
2
1.25
500
3.20
2
787.5
5.04
3.15
1250
Siemens FI 01 · 2016
3/129
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 CT for revenue and bulk metering (7ME6820)
7ME6820xxxx6
DN 50
(2“)
DN 65
(2½“)
DN 80
(3“)
DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600
(4“)
(5“)
(6“)
(8“)
(10“)
(12“)
(14“)
(16“)
(18“)
(20“)
(24“)
„R“ Q3/Q1
250
250
250
250
250
250
250
250
-
-
-
-
-
-
Q4 [m3/h]
50
78.75
125
200
312.5
500
787.5
1250
-
-
-
-
-
-
-
-
Q3 [m3/h]
40
63
100
160
250
400
630
1000
-
-
-
-
[m3/h]
0.26
0.40
0.64
1.02
1.60
2.56
4
6.40
-
-
-
-
-
-
Q1 [m3/h]
0.16
0.25
0.40
0.64
1
1.60
2.52
4
-
-
-
-
-
-
Q2
3
The Label is placed on the side of the encapsulation.
An example of the product label is shown below:
MAG 8000 CT (7ME6820) for Fire Service applications
MAG 8000 CT (7ME6820) is FM Fire Service approved for automatic fire protection systems according to the Fire Service Meters Standard, Class Number 1044. The approval is applicable
for the sizes DN 50, DN 80, DN 100, DN 150, DN 200, DN 250,
and DN 300 (2", 3", 4", 6", 8", 10", and 12") with ANSI B16.5 Class
150 flanges. The FM Fire Service approved product can be ordered via the Z-options P20, P21 and P22.
±E%
FM Fire Service verification tolerances
Installation conditions
Please refer to “System information SITRANS F M electromagnetic flowmeters”.
Battery operation time and calculation
The battery operation time depends on the connected battery
pack as well as the operation condition of the meter.
MAG 8000 calculates the remaining capacity every 4 hours and
includes all consuming elements. Calculation compensates for
temperature influence on battery capacity (drawing).
3/130
Siemens FI 01 · 2016
1.5 %
MAG 8000 CT
Qmin
Qmax
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 CT for revenue and bulk metering (7ME6820)
Selection and Ordering data
Article No.
Article No.
Selection and Ordering data
SITRANS F M
SITRANS F M
MAG 8000 CT water meter with EPDM liner and
Hastelloy electrodes
7ME 6 8 2 0 77777 - 7777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
2Y
3F
3M
DN 100 (4“)
DN 125 (5“)
DN 150 (6“)
3T
4B
4H
DN 200 (8“)
DN 250 (10“)
DN 300 (12“)
4P
4V
5D
DN 350 (14")1)
DN 400 (16")1)
DN 450 (18")1)
5K
5R
5Y
DN 500 (20")1)
DN 600 (24")1)
6F
6P
C
ANSI B16.5
Class 150
J
AS4087
PN 16
N
0
4
3
S
T
12/24 V AC/DC power supply with battery backup
and 3 m (9.8 ft) power cable for external connection
(no battery included)
115 ... 230 V AC power supply with battery backup
and 3 m (9.8 ft) power cable for external connection.
(no battery included)
3
4
Under preparation.
Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and
UN 3091". Special transport documentation is required to observe these
regulations. This may influence both transport time and costs.
3)
For more details and references of the ranges please see the tables on
pages 3/128 to 3/130.
4)
Standard calibration or according to FM Fire Service requirements if P20,
P21 or P22 is selected as Z option.
Operating instructions for SITRANS F M MAG 8000
Description
0
1
2
3
4
5
6
7
Article No.
• English
A5E03071515
• German
A5E00740986
This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Operating instructions for MAG 8000 GSM/GPRS communication module
8
Region version
Europe (m3, m3/h, 50 Hz)
USA (m3, m3/h, 60 Hz)
C
D
0
1
2
1)
3)
Approval/Verification
Without verification according to OIML R 494)
MI-001 Q3/Q1 = 25
MI-001 Q3/Q1 = 63
MI-001 Q3/Q1 = 80
MI-001 Q3/Q1 = 160
MI-001 Q3/Q1 = 200
MI-001 Q3/Q1 = 250
Without verification calibrated to OIML R 49-Class II
(Q3/Q1 = 100)
Without verification calibrated to OIML R 49-Class II
(Q3/Q1 = 250)
B
Internal battery (no battery included)
Internal battery pack installed2)
Power cable (1.5 m (4.9 ft)) with IP68/NEMA 6P
plugs for external battery (no battery included)
2)
Sensor version
EPDM liner and Hastelloy electrodes,
150 m coating
EPDM liner and Hastelloy electrodes,
300 m coating
A
Power supply
Flange norm and pressure rating
EN 1092-1
PN 16
7ME 6 8 2 0 77777 - 7777
Communication interface
No additional "add-on" communication module
installed
Serial RS 485 with Modbus RTU
(Terminated as end device)
Serial RS 232 with Modbus RTU
Encoder interface for ITRON 200WP radio with
"Sensus" protocol"
GSM/GPRS communication module with remote
antenna; 5 m (16.4 ft) cable
GSM/GPRS communication module with analog
inputs and remote antenna; 5 m (16.4 ft) cable
Diameter
DN 50 (2“)
DN 65 (2½“)
DN 80 (3“)
MAG 8000 CT water meter with EPDM liner and
Hastelloy electrodes
Description
Article No.
• English
A5E03644134
1
2
Transmitter type and installation
Basic version integral on sensor
Basic version, remote cables mounted on sensor
with IP68/NEMA 6P plugs
5 m (16.4 ft)
10 m (32.8 ft)
20 m (65.6 ft)
30 m (98.4 ft)
A
Advanced version integral on sensor
Advanced version, remote cables mounted on sensor with IP68/NEMA 6P plugs
5 m (16.4 ft)
10 m (32.8 ft)
20 m (65.6 ft)
30 m (98.4 ft)
K
B
C
D
E
L
M
N
P
Siemens FI 01 · 2016
3/131
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 CT for revenue and bulk metering (7ME6820)
Selection and Ordering data
Order code
Additional information
Please add “-Z“ to Article No. and specify Order
code(s) and plain text.
Material certificate according to EN 10204-3.1
C121)
FP2E marking (France only)
C17
Totalizer
Volume calculation (default totalizer 1= forward and
totalizer 2 = reverse)
3
Totalizer 1 = RV, reverse flow
Totalizer 1 = NET, net flow
Totalizer 2 = FW, forward flow
Totalizer 2 = NET, net flow
L20
L22
L30
L31
Pulse set up
(default pulse A = forward and pulse B = Alarm, pulse
width = 50 ms)
A function = RV, reverse flow
A function = FWnet, forward net flow
A function = RVnet, reverse net flow
A function = Off
L62
L63
L64
L65
Volume per pulse A = x 0.0012)
Volume per pulse A = x 0.012)
Volume per pulse A = x 0.12)
Volume per pulse A = x 12)
L71
L72
L73
L74
B function = FW, forward flow
B function = RV, reverse flow
B function = FWnet, forward net flow
L80
L81
L82
B function = RVnet, reverse net flow
B function = Alarm
B function = Call up
L83
L84
L85
Volume per pulse B = x 0.0012)
Volume per pulse B = x 0.012)
L91
L92
Volume per pulse B = x 0.12)
Volume per pulse B = x 12)
L93
L94
Data logger set up (default month logging)
DataloggerInterval = Daily
DataloggerInterval = Weekly
M31
M32
Factory mounted cables
5 m (16.4 ft) pulse cable A+B
5 m (16.4 ft) communication cable RS 232/RS 485
terminated as end device
M81
M82
20 m (65.6 ft) pulse cable A+B
20 m (65.6 ft) communication cable RS 232/RS 485
terminated as end device
Cello 2 channel, input cable 3 m (9.84 ft) with
Brad Harrison micro-change 3 way connector
Cello 2 channel, input cable 5 m (16.4 ft) with
MIL-C-26482 spec. connectors
5 ft. Encoder interface cable with connector for
ITRON 200WP radio
25 ft. Encoder interface cable with connector for
ITRON 200WP radio
SOFREL data logger cable 2 m with connector for
SOFREL GSM module
M84
M85
FM Fire Service Approval
(with ANSI B16.5 Class 150 flanges)
DN 50, DN 80 and DN 100 (2“, 3" and 4")
DN 150 and DN 200 (6" and 8")
DN 250 and DN 300 (10" and 12")
1)
Under preparation
2)
Pulse width = 10 ms
3/132
Siemens FI 01 · 2016
M87
M89
M91
M90
M92
P20
P21
P22
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 for irrigation applications (7ME6880)
■ Overview
Temperature
Ambient
-20 ... +60 °C (-4 ... +140 °F)
Media
0 ... 70 °C (32 ... 158 °F)
Storage
-40 ... +70 °C (-40 ... +158 °F)
Enclosure rating
Remote sensor
IP68 to EN 60529/NEMA 6P,
10 mH2O cont.
Compact version
IP68 to EN 60529/NEMA 6P,
3 mH2O for six months
Approvals
■ Benefits
• IP68/NEMA 6P rating with tamper proof
• Flexible power supply - internal or external battery pack or
mains power supply with battery back-up possibilities
• No moving parts in a robust construction means less wear and
tear
• Up to 8 years maintenance-free operation in typical application
• Connectable to AMR systems
• Adaptor for conduit installation to provide a clean, protected
pathway for device cables
Drinking water approvals
• ANSI/NSF 611) (cold water) USA
• WRAS (BS 6920 cold water) UK
Custody transfer approval
NMI M 10 Australia
(DN 50 to DN 1200)
Sensor material
Carbon steel ASTM A 105, with corrosion resistant two-component
epoxy coating (150 m/300 m)
Corrosivity category C4, according
to ISO 12944-2
Conformity
IEC/EN 61326
Flanges
EN 1092-1 (DIN 2501) PN 10
drilled pattern
DN 50 ... 600 (2" ... 24")
(max. pressure 7 bar (101.5 psi))
ANSI 16.5 Class 150 drilled pattern 2" ... 24"
(max. pressure 7 bar (101.5 psi))
AS 2091-1 Table D drilled pattern
DN 50 ... 600 (2" ... 24")
(max. pressure 7 bar (101.5 psi))
AS 2129 Table E
DN 25, DN 40, DN 125 (1", 1½", 5")
AS 4087 PN 16
DN 50 ... DN 1200 (2" ... 48")
Excitation frequency
■ Technical specifications
Battery-powered
DN 50 … 600 (2” … 24”): 1/15 Hz
DN 700 … 1200 (28” … 48”):
1/60 Hz
Meter
Accuracy
± 0.8 % ± 2.5 mm/s
± 0.4 % ± 2.5 mm/s
NMI (class 2.5)
Low flow cut-off (default)
1.0 %
Media conductivity
Clean water > 20 s/cm
DN 50 … 600 (2” … 24”): 3.125 Hz
Mains-powered
DN 700 … 1200 (28” … 48”):
1.5625 Hz
Liner
Ebonite
Electrodes
Stainless steel AISI 316Ti/1.4571
1)
Including Annex G
NMI M 10 measuring range
7ME6880
DN 25
(1“)
DN 40
(1½“)
DN 50
(2“)
DN 65
(2½“)
DN 80
(3“)
DN 100
(4“)
DN 125
(5“)
DN 150
(6“)
DN 200
(8“)
DN 250
(10“)
DN 300
(12“)
DN 350
(14“)
„R“ Q3/Q1
10
10
10
10
10
10
10
10
10
10
10
10
Q4 [m3/h]
11.25
28.75
43.75
75
112.5
175
275
375
687.5
750
1625
2125
Q3 [m3/h]
9
23
35
60
90
140
220
300
550
600
1300
1700
0.9
2.3
3.5
6
9
14
22
30
55
60
130
170
7ME6880
DN 400
(16“)
DN 450
(18“)
DN 500
(20“)
DN 600
(24“)
DN 700
(28“)
DN 750
(30“)
DN 800
(32“)
DN 900
(36“)
DN 1000
(40“)
DN 1050
(42“)
DN 1100
(44“)
DN 1200
(48“)
„R“ Q3/Q1
10
10
10
10
10
10
10
10
10
10
10
10
Q4 [m3/h]
2125
2250
2250
2250
4375
4375
5000
5000
5000
5000
5000
5000
Q3 [m3/h]
1700
1800
1800
1800
3500
3500
4000
4000
4000
4000
4000
4000
Q1 [m3/h]
170
180
180
180
350
350
400
400
400
400
400
400
Q1
[m3/h]
Siemens FI 01 · 2016
3/133
3
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 for irrigation applications (7ME6880)
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS F M MAG 8000 water meter
including factory-mounted grounding rings
7 ME 6 8 8 0 -
SITRANS F M MAG 8000 water meter
including factory-mounted grounding rings
7 ME 6 8 8 0 -
77777 - 7777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
No additional "add-on" communication module
installed
Serial RS 485 with Modbus RTU
(Terminated as end device)
Serial RS 232 with Modbus RTU
Encoder inferface
GSM module with remote antenna and 5 m (16.4 ft)
cable
GSM module with analog input, remote antenna
and 5 m (16.4 ft) cable
Diameter
3
DN 25 (1“)
DN 40 (1½“)
DN 50 (2“)
2D
2R
2Y
DN 65 (2½“)
DN 80 (3“)
DN 100 (4“)
3F
3M
3T
DN 125 (5“)
DN 150 (6“)
DN 200 (8“)
4B
4H
4P
DN 250 (10“)
DN 300 (12“)
DN 350 (14“)
4V
5D
5K
DN 400 (16“)
DN 450 (18“)
DN 500 (20“)
5R
5Y
6F
DN 600 (24“)
DN 700 (28“)
DN 750 (30“)
6P
6Y
7D
3
7U
7V
8B
2)
B
J
M
G
N
Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and
UN 3091". Special transport documentation is required to observe these
regulations. This may influence both transport time and costs.
Can be ordered by US region only.
Description
Article No.
• English
A5E03071515
• German
A5E00740986
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
4
Calibration
0
1
3
Region version
1
2
3
Transmitter type and installation
Siemens FI 01 · 2016
5
This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature.
Sensor version
3/134
4
Operating instructions for SITRANS F M MAG 8000
Flange norm and pressure rating
Basic version integral on sensor
Basic version, remote cables mounted on sensor
with IP68/NEMA 6P plugs
2 m (6.56 ft)
5 m (16.4 ft)
10 m (32.8 ft)
20 m (65.6 ft)
30 m (98.4 ft)
T
12/24 V AC/DC power supply with battery backup
and 3 m (9.8 ft) power cable for external connection (no battery included)
115 ... 230 V AC power supply with battery backup
and 3 m (9.8 ft) power cable for external connection (no battery included)
Internal battery pack installed 1 D-cell1) 2)
DN 1050 (42“)
DN 1100 (44“)
DN 1200 (48“)
Europe (m3, m3/h, 50 Hz)
USA (Gallon, GPM, 60 Hz)
Australia (Ml, Ml/d, 50 Hz)
C
D
S
0
1
2
7H
7M
7R
± 0.8 %, ± 2.5 mm/s
± 0.4 %, ± 2.5 mm/s
NMI (2.5 %)
B
Internal battery (no battery included)
Internal battery pack installed 2 D-cell1) 2)
Power cable (1.5 m (4.9 ft)) with IP68/NEMA 6P
plugs for external battery (no battery included)
DN 800 (32“)
DN 900 (36“)
DN 1000 (40“)
Ebonite liner and stainless steel electrodes
A
Power supply
1)
EN 1092-1 drilled pattern PN 10/max. 7 bar (101 psi)
ANSI B16.5 drilled pattern Cl 150/max. 7 bar (101 psi)
AS2129 drilled pattern table D/max. 7 bar (101 psi)
AS2129 table E (DN 25, DN 40, DN 125)
AS4087 PN 16 (DN 50 ... DN 1200)
77777 - 7777
Communication interface
A
T
B
C
D
E
© Siemens AG 2016
Flow Measurement
SITRANS F M
MAG 8000 for irrigation applications (7ME6880)
Selection and Ordering data
Order code
Order code
Selection and Ordering data
Additional information
Additional information
Please add “-Z“ to Article No. and specify Order
code(s) and plain text.
Please add “-Z“ to Article No. and specify Order
code(s) and plain text.
Flow unit
l/s
MGD
CFS
L00
L01
L02
l/min
m3/min
GPM
L03
L04
L05
CFM
l/h
m3/h
L06
L07
L08
GPH
CFH
GPS
L09
L10
L11
Ml/d
m3/d
GPD
L12
L13
L14
Totalizer
Volume calculation (default totalizer 1= forward and
totalizer 2 = reverse)
Totalizer 1 = RV, reverse flow
Totalizer 1 = NET, net flow
Totalizer 2 = FW, forward flow
Totalizer 2 = NET, net flow
L20
L22
L30
L31
Volume unit
m3
Ml
G
L40
L41
L42
AF
l x 100
m3 x 100
L43
L44
L45
G x 100
CF x 100
MG
L46
L47
L48
G x 1000
CF x 1000
AI
kI
L49
L50
L51
L52
Volume per pulse B = x 0.00011)
Volume per pulse B = x 0.0011)
Volume per pulse B = x 0.011)
L90
L91
L92
Volume per pulse B = x 0.11)
Volume per pulse B = x 11)
L93
L94
Device operation
Only operator menu activated
3
M11
Data logger set up (default month logging)
DataloggerInterval = Daily
DataloggerInterval = Weekly
M31
M32
Factory mounted cables
5 m (16.4 ft) pulse cable A+B
5 m (16.4 ft) communication cable RS 232/RS 485
terminated as end device
M81
M82
20 m (65.6 ft) pulse cable A+B
20 m (65.6 ft) communication cable RS 232/RS 485
terminated as end device
Cello 2 channel, input cable 3 m (9.84 ft) with
Brad Harrison micro-change 3 way connector
Cello 2 channel, input cable 5 m (16.4 ft) with
MIL-C-26482 spec. connectors
5 ft Encoder interface cable with connector for
ITRON 200WP radio
25 ft Encoder interface cable with connector for
ITRON 200WP radio
SOFREL data logger cable 2 m with connector for
SOFREL GSM module
Adaptors for conduit installation
M84
M85
1)
M87
M89
M91
M90
M92
M94
Pulse width = 10 ms
Pulse set up
(default pulse A = forward and pulse B = Alarm, pulse
width = 50 ms)
A function = RV, reverse flow
A function = FWnet, forward net flow
A function = RVnet, reverse net flow
A function = Off
L62
L63
L64
L65
Volume per pulse A = x 0.00011)
Volume per pulse A = x 0.0011)
Volume per pulse A = x 0.011)
Volume per pulse A = x 0.11)
Volume per pulse A = x 11)
L70
L71
L72
L73
L74
Pulse A pulse width 5 ms (volume per pulse x 1)
Pulse A pulse width 10 ms (volume per pulse x 1)
Pulse A pulse width 50 ms (volume per pulse x 1)
Pulse A pulse width 100 ms (volume per pulse x 1)
Pulse A pulse width 500 ms (volume per pulse x 1)
L75
L76
L77
L78
L79
B function = FW, forward flow
B function = RV, verse flow
B function = FWnet, forward net flow
L80
L81
L82
B function = RVnet, reverse net flow
B function = Alarm
B function = Call up
L83
L84
L85
Siemens FI 01 · 2016
3/135
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
■ Dimensional drawings
161 (6.34)
161 (6.34)
115 (4.53)
155 (6.10)
155 (6.10)
155 (6.10)
152 (5.98)
152 (5.98)
152 (5.98)
M20
M20
A
A
3
M20
(½“ NPT)
161 (6.34)
A
114 (4.49)
104 (4.09)
84 (3.31)
131 (5.16)
L
7ME6810/7ME6820
DN 25 and 40 (1" and 1½")
7ME6880
L
L
DN 50 ... 300 (2" ... 12")
DN 350 ... 1200 (14" ... 48")
N/A
N/A
DN25...600 (1" ... 24")
For DN 50 ... 300 (2" ... 12"):
Add 7 mm (0.28“) to length (L)
For DN 350 ... 1200 (14" ... 48"):
Add 8 mm (0.31“) to length (L)
Dimensions in mm (inch)
Nominal DN size A
L, lenghts1)
Weight2)
EPDM
(7ME6810 and
7ME6820)
EN 1092-1
PN 10
EN 1092-1
PN 16/
PN 16 non-PED
EN 1092-1
PN 40
ANSI 16.5
Class 150
AS 4087 AWWA C-207 AS 2129
PN 16
Class D
Table E
mm (inch)
mm (inch)
mm
mm
mm
inch
mm
mm
mm
kg
lb
25 (1)
188 (7.4)
-
-
200
7.9
200
-
200
6
13
40 (1½)
203 (8.0)
-
-
200
7.9
200
-
200
9
20
50 (2)
178 (7.0)
-
200
-
7.9
200
-
-
11
25
65 (2½)
181 (7.1)
-
200
-
7.9
200
-
-
13
29
80 (3)
191 (7.5)
-
200
-
7.9
200
-
-
15
34
100 (4)
197 (7.8)
-
250
-
9.8
250
-
-
17
38
125 (5)
210 (8.3)
-
250
-
9.8
250
-
250
22
50
150 (6)
224 (8.8)
-
300
-
11.8
300
-
-
28
63
200 (8)
249 (9.8)
350
350
-
13.8
350
-
-
50
113
250 (10)
276 (10.9)
450
450
-
17.7
450
-
-
71
160
300 (12)
303 (11.9)
500
500
-
19.7
500
-
-
88
198
350 (14)
365 (14.4)
550
550
-
21.7
550
-
-
127
279
400 (16)
391 (15.4)
600
600
-
23.6
600
-
-
145
318
450 (18)
421 (16.6)
600
600
-
23.6
600
-
-
175
384
500 (20)
447 (17.6)
600
600
-
26.8
600
-
-
225
494
600 (24)
497 (19.6)
600
600
-
32.3
600
-
-
340
747
700 (28)
548 (21.6)
700
875/700
-
N/A
700
700
-
316
694
750 (30)
573 (22.6)
N/A
N/A
-
N/A
N/A
750
-
N/A
N/A
800 (32)
603 (23.7)
800
1000/800
-
N/A
800
800
-
398
1045
900 (36)
656 (25.8)
900
1125/900
-
N/A
900
900
-
476
1045
1000 (40)
708 (27.9)
1000
1250/1000
-
N/A
1000
1000
-
602
1322
1050 (42)
708 (27.9)
N/A
N/A
-
N/A
N/A
1050
-
N/A
N/A
1100 (44)
759 (29.9)
N/A
N/A
-
N/A
N/A
1100
-
N/A
N/A
1200 (48)
814 (32.0)
1200
1500/1200
-
N/A
1200
1200
-
887
1996
1)
Tolerances on build in length:
DN 15 to DN 200 (½" to 8"): +0/-3 mm (+0/-0.12"), DN 250 to DN 400 (10" to 16"): +0/-5 mm (+0/-0.20"),
DN 450 to DN 600 (18" to 24"): +5/-5 mm (+0.20/-0.20"), DN 700 to DN 1200 (28" to 48"): +10/-10 mm (+0.39/-0.39")
2) For remote version the sensor weight is reduced with 2 kg (4.5 lb)
3/136
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
13 (0.51)
Remote version
71 (2.80)
31.5 (1.24)
21.5 (0.85)
13 (0.51)
96 (3.78)
Ø8 (0.31)
104 (4.09)
164 (6.46)
Ø8 (0.31)
120 (4.72)
71 (2.80)
Ø12 (0.47)
3
77 (3.03)
50.65 (1.99)
158 (6.22)
Dimensions in mm (inch), weight 3.5 kg (8 lb)
External battery pack
3 (0.12)
4 (0.16)
12.4 (0.49)
75 (2.95)
Ø8 (0.31)
Ø6.5 (0.26)
h
189 (7.44)
Ø12 (0.47)
20 (0.79)
10 (0.39)
44 (1.73)
4 (0.16)
Grounding rings
ØD
76.5 (3.01)
47 (1.85)
18.5 (0.73)
Ød
Dimensions in mm (inch) for grounding rings MAG 8000 with EPDM lining
(7ME6810 and 7ME6820) DN 25 to DN 300
Dimension
Internal
diameter (d)
Outside
diameter (D)
h
DN 25
27
68
143
DN 40
38
88
163
DN 50
52
100
175
DN 65
64
120
195
DN 80
79
133
208
DN 100
95
158
233
DN 125
115
188
263
DN 150
145
216
291
DN 200
193
268
343
DN 250
246
324
399
DN 300
295
374
449
Dimensions in mm (inch), weight 2.0 kg (4.5 lb)
Battery pack has to be mounted in upwards position to ensure
maximum battery capacity.
Siemens FI 01 · 2016
3/137
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
Electrical installation of GSM/GPRS module
■ Schematics
Electrical installation and pulse output – Connection diagram
2
91
92
93
94
95
Module
interface
(option)
3
1
087L4101 002900N423
HL
56
57
66
67
Output A
Output B
+ 3.6 V DC
3
4
V
1 SIM card slot
2 GSM/GPRS antenna connector
3 Analog inputs inlet
4 Rechargeable battery inlet
HL = Hardware lock key connection
V = Push button for verification mode
Pulse wire connection
MAG 8000
External connection
Internal connection
Connection variant
Passive output
Open-Drain
Output A
56
Positive logic
< 50 mA
+
V
0V
V ≤ 35 V DC
Signal
-
57
R
Negative logic
66
Output B
V
0V
67
V ≤ 35 V DC
< 50 mA
+
-
R
Signal
-
The pulse output can be configured as volume, alarm or call-up.
The output can be connected as positive or negative logic.
R = pull up/down is selected in relation to the Vx power supply
and with a max. current I of 50 mA.
Use shielded cable to avoid EMC problems. Make sure the
shield is correctly mounted under the cable clamp (no pig tail).
3/138
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
Accessories
Description
Article No.
Description
Article No.
PC Flow Tool on CD
(Download for free from
www.siemens.com/flow)
FDK:087L6001
One cable entry 2 ... 5 mm
(0.08 ... 0.20 ")
M12 brass glands with M20
reduction2) , package of
10 pcs, for GSM module
antenna cable, power cable
of external battery pack,
encoder card cable
FDK:087L4154
One cable entry 6 ... 8 mm
(0.24 ... 0.31 ") M20 brass
glands package2) (10 pcs),
for pulse output cable or
Modbus cable, Cello cable or
mains power supply
FDK:087L4155
One cable entry 8 ... 11 mm
(0.31 ... 0.43 ") M20 brass
glands package2) (10 pcs),
for SOFREL cable
FDK:087L4156
One cable entry
11 ... 15 mm (0.43 ... 0.59 ")
M20 brass glands package2) (10 pcs)
FDK:087L4157
Two cable entries
3.5 ... 5 mm (0.14 ... 0.20 ")
M20 brass glands package2) (10 pcs)
FDK:087L4158
Two cable entries
5.5 ... 7.5 mm
(0.22 ... 0.30 "), M20 brass
glands package2) (10 pcs)
FDK:087L4159
IrDA infrared interface
adapter with USB for data
acquisition with 1.2 m
(3.9 ft) cable
 FDK:087L4163
Battery backup for mains
power supply, 1 pc. D-cell
(3.6 V, 16.5 Ah)1)
 A5E03354392
Rechargeable Lithium bat-  A5E03436686
tery for MAG 8000
GSM/GPRS communication
module1)
Internal battery pack, one
 FDK:087L4150
set of 2 D-cell (3.6 V, 33 Ah)
and accessories for
replacement1), incl. NBR
O-ring
External battery pack
 FDK:087L4151
IP68/NEMA 6P with connec1)
tor, 4 D-cell (3.6 V, 66 Ah) .
Order cable FDK:087L4152
separately.
Mains power supply
12 ... 24 V AC/DC (average
power consumption during
line  0.1 VA) with battery
backup and 3 m (9.8 ft)
power cable for external connection (no battery included)
Temperature range:
Fixed laying:
-40 ... +90 °C (-40 ... +194 °F)
Flexible application:
-30 ... +80 °C (-22 ... +176 °F)
FDK:087L4210
3
High gain antenna for
MAG 8000 GSM/GPRS
(PVC, IP68, cable length
5 m (16.4 ft), with SMA
male connector (type RG
58) and internal SMA to
SMP female cable adapter,
and single entry cable
gland)
 A5E03436689
Analog input cable for MAG
8000 GSM/GPRS (3 m
(9.8 ft) cable with M12 connector A-Coding female
5 pins, and two-entry cable
gland)
A5E03436698
Mains power supply
 FDK:087L4211
115 ... 230 V AC, 50/60 Hz,
with battery backup up and
3 m (9.8 ft) power cable for
external connection (no battery included)
Potting kit for terminal box of  FDK:085U0220
flow sensors for
IP68/NEMA 6P
RS 232 add-on module,
point to point communication interface with Modbus
RTU protocol
FDK:087L4212
MAG 8000 Hardware key to  FDK:087L4165
access protected parameters
RS 485 add-on module,
multidrop communication
interface with Modbus RTU
protocol
FDK:087L4213
Encoder interface module,
with "Sensus" protocol for
ITRON 200WP and 100W
radio
A5E02475650
MAG 8000 GSM/GPRS
communication module.
Rechargeable battery,
antenna and analog cable
input must be ordered separately
A5E03412758
MAG 8000 demo - training
unit pack operating on Alkaline batteries. Transmitter
with Flow tool CD, IrDA
interface adapter and hardware key (No dangerous
goods limitations)
FDK:087L4080
Siemens FI 01 · 2016
3/139
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
Description
Article No.
Description
Article No.
Alkaline battery for
MAG 8000 demo transmitter
(3 V 13 Ah)
(No dangerous goods limitations)
FDK:087L4142
MAG 8000 (Advanced version) transmitter remote
replacement kit1).
No battery included.
No system number required.
FDK:087L4204
MAG 8000 (Basic version)
transmitter PCB replacement kit1). No system number required.
A5E01171569
MAG 8000 (Advanced version) transmitter PCB
replacement kit1). No system number required.
FDK:087L4168
Enclosure top including
plastic lid, screws, O-ring
and blank product label
FDK:087L4167
Power cable (1.5 m (4.9 ft))
with IP68/NEMA 6P plugs
for external battery (no battery included); PE jacket,
ambient temperature:
-20 ... +60 °C
(-4 ... +140 °F)
FDK:087L4152
5 ft. Encoder interface cable
with IP68/NEMA 6P plugs
included, for ITRON 200WP
and 100W radio; 22 AWG
stranded TC conductors,
polypropylene insulation,
twisted pair, overall Beldfoil
shield, 22 AWG stranded TC
drain wire, PVC jacket
A5E02551263
25 ft. Encoder interface
cable with IP68/NEMA 6P
plugs included, for ITRON
200WP radio; 22 AWG
stranded TC conductors,
polypropylene insulation,
twisted pair, overall Beldfoil
shield, 22 AWG stranded TC
drain wire, PVC jacket
A5E02551182
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
1)
Lithium batteries are subject to special transportation regulations
according to United Nations "Regulation of Dangerous Goods, UN 3090
and UN 3091". Special transport documentation is required to observe
these regulations. This may influence both transport time and costs.
2)
For cable connection through MAG 8000 transmitter bottom part.
3
When MAG 8000 (7ME6810 and 7ME6820) is installed in PVC or
coated pipelines, grounding rings must be installed additionally.
Grounding rings, type C must be used for the 7ME6810 and
7ME6820 routes (sizes > DN 300). Please see grounding rings
in the section MAG 3100 Grounding rings and be aware that the
mentioned MLFB codes include only 1 grounding ring. Grounding rings DN 25 to DN 300 in stainless steel are packed in pairs
and sold as a “grounding ring kit”.
Dimension
Article No.
DN 25
A5E01002946
DN 40
A5E01002947
DN 50
A5E01002948
DN 65
A5E01002950
DN 80
A5E01002952
DN 100
A5E01002953
DN 125
A5E01002954
DN 150
A5E01002955
DN 200
A5E01002957
DN 250
A5E01002958
DN 300
A5E01002962
Spare parts
Description
Article No.
MAG 8000 transmitter compact replacement kit1).
No battery included.With
blank product label.
System number specified by
ordering.
FDK:087L4166
MAG 8000 transmitter
remote replacement kit1).
No battery included.
With blank product label.
System number specified by
ordering.
FDK:087L4202
MAG 8000 (Advanced version) transmitter compact
replacement kit1).
No battery included.
With blank product label.
No system number required.
FDK:087L4203
3/140
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
Battery-operated water meter MAG 8000
Description
Article No.
Service tool kit package with
various component for service and replacement.
Content:
10 plastic top lids
20 screws
10 wire holders
10 battery cups
10 greased O-rings
20 clamp kits
10 IrDA adaptor holding rings
FDK:087L4162
MAG 8000 (7ME6880) grounding ring service kit, consisting of
2 pcs. grounding rings (AISI 304/1.4301), screws and gaskets
Article No.
Dimension
10
20
10
10
10
20
10
Remote cable set 5 m
(16.4 ft) with IP68/NEMA 6P
plugs - PG 13.52)
FDK:087L4108
Remote cable set 5 m
(16.4 ft) with IP68/NEMA 6P
plugs - M20
A5E00862482
Remote cable set 10 m
(32.8 ft) with IP68/NEMA 6P
plugs - PG 13.52)
FDK:087L4109
Remote cable set 10 m
(32.8 ft) with IP68/NEMA 6P
plugs - M20
A5E00862487
Remote cable set 20 m
(65.6 ft) with IP68/NEMA 6P
plugs - PG 13.52)
FDK:087L4110
Remote cable set 20 m
(65.6 ft) with IP68/NEMA 6P
plugs - M20
A5E00862492
Remote cable set 30 m
(98.4 ft) with IP68/NEMA 6P
plugs - PG 13.52)
FDK:087L4111
Remote cable set 30 m
(98.4 ft) with IP68/NEMA 6P
plugs - M20
A5E00862497
10 m cable set with premounted conduit adaptor
A5E33400834
20 m cable set with premounted conduit adaptor
A5E33400836
1)
Not applicable to custody transfer (CT) verified systems without
re-verification
2)
For sensors produced before October 2007.
Drilled pattern flanges (7 bar)
DN 50
2"
A5E03082907
DN 65
2½"
A5E03082908
DN 80
3"
A5E03082909
DN 100
4"
A5E03082910
DN 125
5"
A5E03082911
DN 150
6"
A5E32877967
DN 200
8"
A5E03082913
DN 250
10"
A5E03082914
DN 300
12"
A5E03082915
DN 350
14"
A5E03082916
DN 400
16"
A5E03082917
DN 450
18"
A5E03082918
DN 500
20"
A5E03082919
DN 600
24"
A5E03082920
3
AS 2191 table E flanges
DN 25
1"
A5E33474999
DN 40
1½"
A5E33475000
DN 125
5"
A5E33475006
AS 4087 PN 16 flanges
DN 50
2"
A5E33475001
DN 65
2½"
A5E33475002
DN 80
3"
A5E33475003
DN 100
4"
A5E33475004
DN 150
6"
A5E33475007
DN 200
8"
A5E33475008
DN 250
10"
A5E33475009
DN 300
12"
A5E33475010
DN 350
14"
A5E33475011
DN 400
16"
A5E33475012
DN 450
18"
A5E34240921
DN 500
20"
A5E33475013
DN 600
24"
A5E33475014
DN 700
28"
A5E33414889
DN 800
32"
A5E33414890
DN 900
36"
A5E33414891
DN 1000
40"
A5E33414892
DN 1200
48"
A5E33414893
Siemens FI 01 · 2016
3/141