MAG 5100W Catalog Specifications Sheet

© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
■ Overview
■ Application
The main applications of the SITRANS F M electromagnetic flow
sensors can be found in the following fields:
• Water abstraction
• Water treatment
• Water distribution network (leak detection management)
• Custody transfer water meters
• Irrigation
• Waste water treatment
• Filtration plant (e.g. reverse osmosis and ultra filtration)
• Industrial water applications
3
■ Mode of operation
The flow measuring principle is based on Faradays law of electromagnetic induction according to which the sensor converts
the flow into an electrical voltage proportional to the velocity of
the flow.
■ Integration
The complete flowmeter consists of a flow sensor and an associated transmitter SITRANS F M MAG 5000, MAG 6000 or
MAG 6000 I.
The SITRANS F M MAG 5100 W is an electromagnetic flow sensor designed to meet ground water, drinking water, waste water,
sewage or sludge applications.
■ Benefits
• DN 15 to DN 1200 / 2000 (½” to 48"/78”)
• Stock program of MAG 5100 W secures short delivery time
• Connection flanges EN 1092-1 (DIN 2501), ANSI, AWWA, AS
and JIS.
• NBR Hard Rubber and Ebonite Hard Rubber liner for all water
applications
• EPDM liner with drinking water approvals
• Hastelloy integrated grounding and measuring electrodes
• Increased low flow accuracy for water leak detection, due to
coned liner design (Article No. 7ME6520, DN 15 to 300 mm
(½" to 12")).
• Drinking water approvals
• Suitable for direct burial and constant flooding
• Custody transfer approvals
• Build-in length according to ISO 13359; the standard includes
sizes up to DN 400.
• Easy commissioning, SENSORPROM unit automatically uploads calibration values and settings.
• Designed so patented in-situ verification can be conducted.
Using SENSORPROM fingerprint.
• Custody transfer option for water billing, with type approval after OIML R 49 and verified according to MI-001 - 0D inlet/
0D outlet installation
- pattern approval OIML R 49 (Denmark, Germany)
- conform to ISO 4064 and EN 14154 for mechanical flowmeters
- PTB K7.2
- Kiwa water approval
• FM Fire Service Meter (Class Number 1044) for automatic fire
protection systems
• Meets EEC directives: PED, 2014/68/EU pressure directive for
EN1092-1 flanges
• Simple onsite or factory upgrade to IP68/NEMA 6P of a standard sensor
• MCERTS approval for UK environmental market
3/92
Siemens FI 01 · 2016
The flexible communication concept USM II simplifies integration and update to a variety of fieldbus systems, e.g. HART,
DeviceNet, PROFIBUS DP and PA, FOUNDATION Fieldbus H1
or Modbus RTU/RS 485.
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
■ Technical specifications
Product characteristic
MAG 5100 W (7ME6520)
Mainly for the European market
MAG 5100 W (7ME6580)
Mainly for the non-European market
EPDM or NBR lining
Ebonite lining
Design and nominal size
Coned sensor
(octagon liner): DN 15 ... 40 (½” ... 1½”)
Coned sensor: DN 50 ... 300 (2” ... 12”)
Full bore sensor: DN 350 ... 1200 (14” ... 48”)
Full bore sensor: DN 25 ... 2000 (1” ... 78”)
Measuring principle
Electromagnetic induction
Electromagnetic induction
Excitation frequency (Mains supply: 50/60 Hz)
DN 15 ... 65 (½” ... 2½”): 12.5 Hz/15 Hz
DN 80 ... 150 (3” ... 6”): 6.25 Hz/7.5 Hz
DN 200 ... 300 (8” ... 12”): 3.125 Hz/3.75 Hz
DN 350 ... 1200 (14” ... 48”): 1.5625 Hz/1.875 Hz
DN 25 ... 65 (1” ... 2½”): 12.5 Hz/15 Hz
DN 80 ... 150 (3” ... 6”): 6.25 Hz/7.5 Hz
DN 200 ... 1200 (8” ... 48”): 3.125 Hz/3.75 Hz
DN 1400 ... 2000 (54” ... 78”): 1.5625 Hz/1.875 Hz
• EN 1092-1
PN 10 (145 psi) : DN 200 ... 300 (8” ... 12”)
Flat face
PN 10 (145 psi): DN 350 ... 1200 (14” ... 48”)
Raised face2)
PN 16 (232 psi): DN 50 ... 300 (2” ... 12”)
Flat face3)
PN 16 (232 psi): DN 350 ... 1200 (14” ... 48”)
Raised face
PN 40 (580 psi): DN 15 ... 40 (½” ... 1½”)
Flat face
Raised face3) (EN 1092-1, DIN 2501 and BS
4504 have the same mating dimensions)
PN 6 (87 psi): DN 1400 ... 2000 (54” ... 78”)
PN 10 (145 psi): DN 200 ... 2000 (8” ... 78”)
PN 16 (232 psi): DN 65 ... 600 (2½” ... 24”)
PN 40 (580 psi): DN 25 ... 50 (1” ... 2”)
• ANSI B16.5
Class 150: ½" ... 12" flat face;
14" ... 24" raised face
Class 150: 1” ... 24”; raised face
• AWWA C-207
Class D: 28” ... 48”, flat face
Class D: 28” ... 78”, flat face
• AS4087
PN 16 (DN 50 ... 1200), (2" ... 48")
16 bar (232 psi)
PN 16 (DN 50 ... 1200), (2" ... 48")
16 bar (232 psi)
• JIS B 2220:2004
-
K10 (1" ... 24")
Process connection
Flanges1)
Rated Operation conditions
Ambient temperature
• Sensor
-40 ... +70 °C (-40 ... +158 °F)
-20 ... +70 °C (-4 ... +158 °F)
• With compact transmitter MAG 5000/60004)
-20 ... +60 °C (-4 ... +140 °F)
-20 ... +60 °C (-4 ... +140 °F)
Operating pressure (Abs)
[abs. bar] (Maximum operating pressure
depending on flange standard, decreases with
increasing operating temperature)
DN 15 ... 40 (½” ... 1½”):
0.01 ... 40 bar (0.15 ... 580 psi)
DN 50 ... 300 (2” ... 12”):
0.03 ... 20 bar (0.44 ... 290 psi)
DN 350 ... 1200 (14” ... 48”):
0.01 ... 16 bar (0.15 ... 232 psi)
DN 25 ... 50 (1” ... 2”):
0.01 ... 40 bar (0.15 ... 580 psi)
DN 65 ... 1200 (2½” ... 48”):
0.01 ... 16 bar (0.15 ... 232 psi)
DN 1400 ... 2000 (54” ... 78”):
0.01 ... 10 bar (0.15 ... 145 psi)
• Standard
IP67 to EN 60529/NEMA 4X/6
(1 mH2O for 30 min)
IP67 to EN 60529/NEMA 4X/6
(1 mH2O for 30 min)
• Option
IP68 to EN 60529/NEMA 6P
(10 mH2O continuously)
IP68 to EN 60529/NEMA 6P
(10 mH2O continuously)
Pressure drop
DN 15 and 25 (½" and 1"): Max. 20 mbar (0.29 psi) Insignificant
at 1 m/s (3 ft/s).
DN 40 ... 300 (1½" ... 12"): Max 25 mbar (0.36 psi)
at 3 m/s (10 ft/s)
DN 350 ... 1200 (14” ... 48”): Insignificant
Test pressure
1.5 x PN (where applicable)
FM Fire Service: 2 x PN
1.5 x PN (where applicable)
Mechanical load (vibration)
18 ... 1000 Hz random in x, y, z, directions for
2 hours according to EN 60068-2-36
Sensor: 3.17 g RMS
Sensor with compact MAG 5000/6000 mounted
transmitter: 3.17 g RMS
Sensor with compact MAG 6000 I mounted
transmitter: 1.14 g RMS
18 ... 1000 Hz random in x, y, z, directions for
2 hours according to EN 60068-2-36
Sensor: 3.17 g RMS
Sensor with compact MAG 5000/6000 mounted
transmitter: 3.17 g RMS
Sensor with compact MAG 6000 I mounted
transmitter: 1.14 g RMS
Enclosure rating
Siemens FI 01 · 2016
3/93
3
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
Product characteristic
Mainly for the European market (7ME6520)
Mainly for the non-European market
(7ME6580)
EPDM or NBR lining
Ebonite lining
Medium conditions
Temperature of medium
3
• NBR
-10 ... +70 °C (14 ... 158 °F)
-
• EPDM
-10 ... +70 °C (14 ... 158 °F)
-
• EPDM/NBR (MI-001)
0.1 ... 30 °C (32 ... 76 °F)
-
• Ebonite
-
-10 ... +70 °C (14 ... 158 °F)
EMC
2014/30/EU
2014/30/EU
• Housing and flanges
Carbon steel ASTM A 105, with corrosionresistant two-component epoxy coating
(150 m/300 m)
Corrosivity category C2+, according to
ISO 12944-2
Carbon steel ASTM A 105, with corrosionresistant two-component epoxy coating
(150 m/300 m)
Corrosivity category C2+, according to
ISO 12944-2
• Measuring pipe
Stainless steel AISI 304/1.4301
Stainless steel AISI 304/1.4301
• Electrode
Hastelloy C276
Hastelloy C276
• Grounding electrode
Hastelloy C276
Hastelloy C276
• Terminal box
Fibre glass reinforced polyamide
Fibre glass reinforced polyamide
• Standard production calibration (default),
calibration report shipped with sensor
Zero-point, 2 x 25 % and 2 x 90 %
Zero-point, 2 x 25 % and 2 x 90 %
• Special calibration
5-point calibration: 20 %, 40 %, 60 %, 80 %,
100 % of factory Qmax
10-point calibration: ascending and descending at
20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax
Matched-pair calibration: default, 5-point or 10point
5-point calibration: 20 %, 40 %, 60 %, 80 %,
100 % of factory Qmax
10-point calibration: ascending and descending at
20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax
Matched-pair calibration: default, 5-point or 10point
Material certificate EN 10204 3.1
Available when ordering together with meter5)
Available when ordering together with meter5)
meter5)
Available when ordering together with meter5)
Design
Material
Certificates and approvals
Calibration
Pressure test certificate
Available when ordering together with
Custody transfer (only together with
MAG 6000 CT)
OIML R 49 pattern approval cold water (Denmark and Germany): DN 50 ... DN 300 (2“ ... 12")
MI-001 cold water (EU): DN 50 ... DN 1200 (2“ ... 48")
PTB K7.2: Chilled water energy metering
DN 50-300 (order as special)
Certificate number: 22 76.10 02
Kiwa water approval: DN 50 ... DN 1200 (2" ... 48")
Drinking water approvals
EPDM liner:
NSF/ANSI Standard 616) (Cold water, US)
WRAS (WRc, BS6920 cold water, GB)
ACS (F), DVGW W270 (D), Belgaqua (B)
Other approvals
MCERTS
PED conforming: All EN1092-1 flanges and ANSI
Class 150 (< DN 300 (<12”)) – 2014/68/EU7)
CMC/CPA
CSA Class I, Div 28)
FM Class I, Div 28)
FM Fire Service Approval according to class
10448)9)
VdS: Extinguishing systems DN 50 ... DN 300
1)
2)
3)
4)
5)
6)
NSF/ANSI Standard 616) (Cold water, US)
WRAS (WRc, BS6920 cold water, GB)
PED conforming: All EN1092-1 flanges
( DN 600 ( 24") – 2014/68/EU7)
CMC/CPA
CSA Class I, Div 28)
FM Class I, Div 28)
DN 750, DN 1050 and DN 1100 (30", 42" and 44") not available with EN 1092-1 (PN 10 and PN 16) and AS4087 flanges
Type 01 (SORF)
DN  600 type 01 (SORF); DN > 600 type 11
With compact transmitter MAG 5000 CT/6000 CT -20 ... +50 °C (-4 ... +122 °F); with compact MI-001 approved transmitter -25 ... +55 ºC (-13 ... +131 ºF)
Has to be ordered with the meter. It is not possible to order the certificate afterwards.
Including Annex G
For sizes larger than 600 mm (24”) in PN 16 PED conformity is available as a cost-added option. The basic unit will carry the LVD (Low Voltage Directive) and EMC
approval. All products sold outside of EU and EFTA are excluded from the directive, also products sold into certain market sectors are excluded. These include:
a) Meters used in networks for the supply, distribution and discharge of water.
b) Meters used in pipelines for the conveyance of any fluid from offshore to onshore.
c) Meters used in the extraction of petroleum or gas, including Christmas tree and manifold equipment.
d) Any meter mounted on a ship or mobile offshore platform. For further information on the PED standard and requirements see page 9/6.
8)
Not for sensors with 300 m coating.
9) DN 50, DN 80, DN 100, DN 150, DN 200, DN 250, and DN 300 (2", 3", 4", 6", 8", 10", and 12") with ANSI B16.5 Class 150 flanges
7)
3/94
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
MAG 5100 W (7ME6520) with MAG 6000 CT
(Revenue program) MI-001
MAG 5100 W (7ME6520) with MAG 5000/MAG 6000 or
MAG 6000 CT for Fire Service applications
MAG 5100 W CT program is type approved according to international water meter standard OIML R 49. Since the first November 2006 the MI-001 water meter directive is in force, which
means that all water meters can be sold across the EU borders
if the water meters contain a MI-001 label.
The MAG 5100 W MI-001 verified and labeled products are a
Class II approval according to Directive 2014/32/EU of the
European Parliament and Council of 26 February, 2014 on measuring instruments, Annex VI Thermal Energy Meters (MI-004) in
the sizes from DN 50 to DN 1200 (Article No. 7ME6520).
The MID certification is obtained as a modul B + D module approval according to the above mentioned directive.
Module B : Type approval according to OIML R 49
Module D : Quality insurance approval of production
MAG 5100 W (7ME6520) is FM Fire Service approved for automatic fire protection systems. The approval is applicable for the
sizes DN 50, DN 80, DN 100, DN 150, DN 200, DN 250 and
DN 300 (2", 3", 4", 6", 8", 10" and 12") with ANSI B16.5 Class 150
flanges. The FM Fire Service approved product can be ordered
via the Z-options P20, P21 and P22.
±E%
FM Fire Service verification tolerances
3
1.5 %
MI-001 verification tolerances
±E%
Qmin
Cl. II = 5%
Qmax
Cl. II = 2%
Q1 Q2
Q3
Q4
Siemens FI 01 · 2016
3/95
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
MAG 5100 W (7ME6520) MI-001 verified and labeled products at a given Q3 and Q3/Q4 = 1.25 and Q2/Q1 = 1.6 measuring ranges see
table below:
3
Order code: P11
DN 50 (2“) DN 65 (2½“) DN 80 (3“)
DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“)
„R“ Q3/Q1
25
25
25
25
25
25
25
25
25
Q4 [m3/h]
20
31.25
50
78.75
125
200
312.5
500
787.5
Q3 [m3/h]
16
25
40
63
100
160
250
400
630
Q2 [m3/h]
1.02
1.6
2.6
4.0
6.4
10.2
16
25.6
40.3
Q1 [m3/h]
0.64
1.00
1.60
2.52
4.0
6.4
10.0
16.0
25.2
Order code: P12
DN 50 (2“) DN 65 (2½“) DN 80 (3“)
DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“)
„R“ Q3/Q1
63
63
63
63
63
63
63
63
63
[m3/h]
20
31.25
50
78.75
125
200
312.5
500
787.5
Q3 [m3/h]
16
25
40
63
100
160
250
400
630
Q2 [m3/h]
0.41
0.63
1.02
1.6
2.5
4.1
6.3
10.2
16.0
Q1 [m3/h]
0.25
0.40
0.63
1.00
1.59
2.54
3.97
6.35
10.0
Order code: P13
DN 50 (2“) DN 65 (2½“) DN 80 (3“)
DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“)
„R“ Q3/Q1
80
80
80
80
80
80
80
80
80
Q4 [m3/h]
20
31.3
50
78.75
125
200
313
500
1250
Q3 [m3/h]
16
25
40
63
100
160
250
400
1000
Q2 [m3/h]
0.32
0.5
0.8
1.3
2.0
3.2
5.0
8.0
20.0
Q1 [m3/h]
0.20
0.31
0.50
0.79
1.25
2.00
3.13
5.00
12.50
Order code: P16
DN 50 (2“) DN 65 (2½“) DN 80 (3“)
DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“)
„R“ Q3/Q1
160
160
160
160
160
160
160
160
160
Q4 [m3/h]
78.75
125
200
313
500
788
1250
2000
2000
Q4
Q3
[m3/h]
63
63
160
250
400
400
1000
1600
1600
Q2 [m3/h]
0.63
1.0
1.6
2.5
4.0
6.3
10.0
16.0
16.0
Q1 [m3/h]
0.39
0.63
1.00
1.56
2.50
3.94
6.25
10.00
10.00
Order code: P17
DN 50 (2“) DN 65 (2½“) DN 80 (3“)
DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“)
„R“ Q3/Q1
200
200
200
200
200
200
200
200
200
Q4 [m3/h]
78.75
125
200
313
500
788
1250
2000
2000
Q3 [m3/h]
63
100
160
250
400
630
1000
1600
1600
Q2 [m3/h]
0.50
0.80
1.3
2.0
3.2
5.0
8.0
12.8
12.8
[m3/h]
0.32
0.50
0.80
1.25
2.00
3.15
5.00
8.00
8.00
Q1
Order code: P18
DN 50 (2“) DN 65 (2½“) DN 80 (3“)
DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“)
„R“ Q3/Q1
250
250
250
250
250
250
250
250
250
Q4 [m3/h]
78.75
125
200
313
500
788
1250
2000
2000
Q3 [m3/h]
63
100
160
250
400
630
1000
1600
1600
Q2 [m3/h]
0.4
0.64
1.0
1.6
2.6
4.0
6.4
10.2
10.2
Q1 [m3/h]
0.25
0.40
0.64
1.00
1.60
2.52
4.00
6.40
6.40
Order code: P24
DN 350 (14")
DN 400 (16“)
DN 450 (18“)
DN 500 (20“)
DN 600 (24“)
„R“ Q3/Q1
25
25
25
25
25
Q4 [m3/h]
1250
1250
1250
2000
3125
Q3 [m3/h]
1000
1000
1000
1600
2500
Q2 [m3/h]
64
64
64
102
160
Q1 [m3/h]
40
40
40
64
100
Order code: P25
DN 350 (14")
DN 400 (16“)
DN 450 (18“)
DN 500 (20“)
DN 600 (24“)
„R“ Q3/Q1
63
63
63
63
63
Q4 [m3/h]
1250
1250
3125
3125
5000
Q3 [m3/h]
1000
1000
2500
2500
4000
Q2 [m3/h]
25
25
63
63
102
Q1 [m3/h]
15.9
15.9
39.7
39.7
63.5
3/96
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
Order code: P26
DN 350 (14")
DN 400 (16“)
DN 450 (18“)
DN 500 (20“)
DN 600 (24“)
„R“ Q3/Q1
80
80
80
80
80
Q4 [m3/h]
2000
2000
3125
3125
5000
Q3 [m3/h]
1600
1600
2500
2500
4000
Q2 [m3/h]
32
32
50
50
80
Q1 [m3/h]
20
20
31.25
31.3
50
Order code: P27
DN 350 (14")
DN 400 (16“)
DN 450 (18“)
DN 500 (20“)
DN 600 (24“)
„R“ Q3/Q1
160
160
160
160
160
Q4 [m3/h]
2000
3125
3125
5000
7875
Q3 [m3/h]
1600
4000
4000
6300
6300
Q2 [m3/h]
16
25
25
40
63
Q1 [m3/h]
10.00
15.63
15.63
25.00
39.38
Order code: P29
DN 700 (28“)
DN 750 (30“)
DN 800 (32“)
DN 900 (36“)
DN 1000 (40“)
DN 1200 (48“)
„R“ Q3/Q1
25
25
25
25
25
25
Q4 [m3/h]
5000
5000
5000
7875
7875
7875
Q3 [m3/h]
4000
4000
4000
6300
6300
6300
Q2 [m3/h]
256
256
256
403
403
403
Q1 [m3/h]
160
160
160
252
252
252
Order code: P30
DN 700 (28“)
DN 750 (30“)
DN 800 (32“)
DN 900 (36“)
DN 1000 (40“)
DN 1200 (48“)
„R“ Q3/Q1
63
63
63
63
63
-
Q4 [m3/h]
5000
5000
5000
7875
7875
-
Q3 [m3/h]
4000
4000
4000
6300
6300
-
Q2 [m3/h]
102
102
102
160
160
-
Q1 [m3/h]
63.5
63.5
63.5
100
100
-
Order code: P31
DN 700 (28“)
DN 750 (30“)
DN 800 (32“)
DN 900 (36“)
DN 1000 (40“)
DN 1200 (48“)
„R“ Q3/Q1
80
80
80
80
-
-
Q4 [m3/h]
5000
5000
5000
7875
-
-
Q3 [m3/h]
4000
4000
4000
6300
-
-
Q2 [m3/h]
80
80
80
126
-
-
Q1 [m3/h]
50.0
50.0
50.0
78.8
-
-
The label is placed on the transmitter housing. An example of the
product label is shown below:
3
OIML R 49/MI-001 approvals valid for:
• DN 50 to DN 1200 (2" to 48").
As special requests (PVR) available up to DN 2000 (80")
• Horizontal installation
• Compact or remote with max. 500 m cable
• Power supply 115 to 230 V AC, 12 to 24 V AC/DC
• With or without communication module
Other restrictions may apply (see certificate).
Special OIML / MI-001 settings:
• Unit: m3
• Qmax: Q3
• Digital output: Frequency
For other factory settings, see Operating Instructions.
Siemens FI 01 · 2016
3/97
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
Selection and Ordering data
Article No. Order Code
Selection and Ordering data
Article No. Order Code
Sensor SITRANS F M MAG 5100 W
Hastelloy electrodes, carbon steel flanges,
EU water markets and low flow applications
7 ME 6 5 2 0 -
Sensor SITRANS F M MAG 5100 W
Hastelloy electrodes, carbon steel flanges,
EU water markets and low flow applications
7 ME 6 5 2 0 -
77777 - 2 777 777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Transmitter
Sensor for remote transmitter (Order trans- 
mitter separately)
MAG 6000 I, Aluminum, 18 ... 90 V DC,

115 ... 230 V AC
Diameter
3
DN 15 (½“)
DN 25 (1“)
DN 40 (1½“)
DN 50 (2“)




DN 65 (2½“)
DN 80 (3“)
DN 100 (4“)
 3F
 3M
 3T
DN 125 (5“)
DN 150 (6“)
DN 200 (8“)
 4B
 4H
 4P
DN 250 (10“)
DN 300 (12“)
DN 350 (14“)
 4V
 5D
5K
DN 400 (16“)
DN 450 (18“)
DN 500 (20“)
5R
5Y
6F
DN 600 (24“)
DN 700 (28“)
DN 750 (30“)
6P
6Y
7D
DN 800 (32“)
DN 900 (36“)
DN 1000 (40“)
7H
7M
7R
(42“)
(44“)
DN 1200 (48“)
7U
7V
8B
1V
2D
2R
2Y
MAG 6000, Polyamid,
11 ... 30 V DC/11 ... 24 V AC
MAG 6000, Polyamid, 115 ... 230 V AC
MAG 5000, Polyamid,
11 ... 30 V DC/11 ... 24 V AC
MAG 5000, Polyamid, 115 ... 230 V AC
MAG 6000 CT, Polyamid, 115 ... 230 V AC
MAG 6000 CT, Polyamid,
11 ... 30 V DC/11 ... 24 V AC
Communication
None
HART
PROFIBUS PA Profile 3 (only MAG 6000/
MAG 6000 I)
PROFIBUS DP Profile 3 (only MAG 6000/
MAG 6000 I)
Modbus RTU/RS 485 (only MAG 6000/
MAG 6000 I)
FOUNDATION Fieldbus H1 (only MAG 6000/
MAG 6000 I)
Cable glands/terminal box
Metric/Polyamid terminal box or 6000 I
compact
½" NPT/Polyamid terminal box or 6000 I
compact
B
C
D
F
to ANSI B16.5
class 150 (½“ ... 24“)
J
to AWWA C-207
Class D (28“ ... 48“)
L
to AS 4087
PN 16 (DN 50 ... 1200/2“ ... 48“)
N
Flange material and coating
Carbon steel flanges ASTM A 105, 150 m 
coating
Carbon steel flanges ASTM A 105, 300 m
coating
Liner material
EPDM
NBR Hard Rubber
3/98
Siemens FI 01 · 2016


A
C

H


J
K

L
M
R



A
B
F

G

E

J

1

2
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Flange norm and pressure rating
to EN 1092-1
PN 10 (DN 200 ... 1200/8“ ... 48“)

PN 16 (DN 50 ... 1200/2“ ... 48“)

PN 16, non PED (DN 700 ... 1200/28“ ... 48“)
PN 40 (DN 15 ... 40/½“ ... 1½“)


77777 - 2 777 777
1
4
2
3
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
Selection and Ordering data
Order code
Order code
Selection and Ordering data
FM Fire Service Approval
(with ANSI B16.5 Class 150 flanges)
Additional information
Please add “-Z“ to Article No. and specify Order
code(s) and plain text.
• DN 50, DN 80 and DN 100 (2", 3" and 4")
P20
Pressure test certificate according to EN 10204-3.1
C01
• DN 150 and DN 200 (6" and 8")
P21
Material certificate according to EN 10204-3.1
C12
• DN 250 and DN 300 (10" and 12")
P22
Factory certificate according to EN 10204-2.2
C14
Y17
Factory certificate according to EN 10204-2.1
C15
Tag name plate, stainless steel fixed with SS wire
(add plain text)
FP2E marking (only France)
C17
Tag name plate, plastic (self-adhesive)
Y18
Customer-specific converter setup
Y20
Sensor cables wired (specify cable Article No.)
Y40
Sensor for remote transmitter's junction box potted to
IP68 with wired cable (specify cable Article No.)
Y41
Other postproduction requirements (add desired text)
Y99
Region specific approvals and certificates
• Chinese label translation
• KCC label
W06
W28
Special calibration
3
• 5-point calibration for DN 15 ... DN 2001)
• 5-point calibration for DN 250 ... DN 6001)
• 5-point calibration for DN 700 ... DN 12001)
D01
D02
D03
Additional Calibrations
Accredited Siemens Flow Instruments matched pair
Calibration acc. to ISO/IEC 17025:2005
On request5)
• 10-point calibration for DN 15 ... DN 2002)
• 10-point calibration for DN 250 ... DN 6002)
• 10-point calibration for DN 700 ... DN 12002)
D06
D07
D08
Customer-witnessed calibration
Any of above calibration
On request5)
1)
• Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 15 ... DN 200
• Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 250 ... DN 600
• Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 700 ... DN 1200
D11
20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax
2)
D12
Ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory
Qmax
3)
D13
For more details and references of the ranges please see the tables on
page 3/96.
4)
For remote version submit Product Variation Request.
5)
• 5-point, matched-pair calibration for
DN 15 ... DN 2001)
• 5-point, matched-pair calibration for
DN 250 ... DN 6001)
• 5-point, matched-pair calibration for
DN 700 ... DN 12001)
D15
Ordering On request as dedicated information from the customer on the
individual sensors is required.
• 10-point, matched-pair calibration for
DN 15 ... DN 2002)
• 10-point, matched-pair calibration for
DN 250 ... DN 6002)
• 10-point, matched-pair calibration for
DN 700 ... DN 12002)
Terminal blocks
• Factory mounted terminal blocks
D16
Operating instructions for SITRANS F M MAG 5100 W
D17
D18
D19
D20
N02
Description
Article No.
• English
• German
A5E03063678
A5E03376527
This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Accessories
,
Approval/Verification3)
Description
(MI-001 : DN 50 ... DN 300 (compact only), EN 1092-1
PN10 and PN16 flanges with MAG 6000 CT)4)
Potting kit for terminal box
of flow sensors for
IP68/NEMA 6P
• Without verification according to OIML R 49
(DN 50 ... DN 300)
P10
• MI-001 Q3/Q1 = 25 (DN 50 ... DN 300)
P11
• MI-001 Q3/Q1 = 63 (DN 50 ... DN 300)
P12
• MI-001 Q3/Q1 = 80 (DN 50 ... DN 300)
P13
• MI-001 Q3/Q1 = 160 (DN 50 ... DN 300)
P16
• MI-001 Q3/Q1 = 200 (DN 50 ... DN 300)
P17
• MI-001 Q3/Q1 = 250 (DN 50 ... DN 300)
P18
• Without verification according to OIML R 49
(DN 350 ... DN 600)
P23
• MI-001 Q3/Q1 = 25 (DN 350 ... DN 600)
P24
• MI-001 Q3/Q1 = 63 (DN 350 ... DN 600)
P25
• MI-001 Q3/Q1 = 80 (DN 350 ... DN 600)
P26
• MI-001 Q3/Q1 = 160 (DN 350 ... DN 600)
P27
• Without verification according to OIML R 49
(DN 700 ... DN 1200)
P28
• MI-001 Q3/Q1 = 25 (DN 700 ... DN 1200)
P29
• MI-001 Q3/Q1 = 63 (DN 700 ... DN 1200)
P30
• MI-001 Q3/Q1 = 80 (DN 700 ... DN 1200)
P31
Article No.
 FDK:085U0220
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
MAG 5000/6000 transmitters and sensors are packed in separate boxes, the final assembly takes place during installation at
the customer's place. MAG 6000 I transmitters and sensors are
delivered compact mounted from factory.
Communication module will be pre-mounted in the transmitter.
Please use online Product selector to get latest updates.
Product selector link:
www.pia-portal.automation.siemens.com
Siemens FI 01 · 2016
3/99
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
Sensor SITRANS F M MAG 5100 W
7 ME 6 5 8 0 -
Sensor SITRANS F M MAG 5100 W
7 ME 6 5 8 0 -
Hastelloy electrodes, carbon steel flanges,
Non EU water markets
77777 - 7777
Hastelloy electrodes, carbon steel flanges,
Non EU water markets
77777 - 7777
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Transmitter with display
Diameter
3
DN 25 (1“)
DN 40 (1½“)
DN 50 (2“)
 2D
 2R
 2Y
DN 65 (2½“)
DN 80 (3“)
DN 100 (4“)
 3F
 3M
 3T
DN 125 (5“)
DN 150 (6“)
DN 200 (8“)
 4B
 4H
 4P
DN 250 (10“)
DN 300 (12“)
DN 350 (14“)
 4V
 5D
5K
DN 400 (16“)
DN 450 (18“)
DN 500 (20“)
5R
5Y
6F
DN 600 (24“)
DN 700 (28“)
DN 750 (30“)
6P
6Y
7D
DN 800 (32“)
DN 900 (36“)
DN 1000 (40“)
7H
7M
7R
(42“)
(44“)
7U
7V
DN 1200 (48“)
DN 1400 (54“)
DN 1500 (60“)
8B
8F
8K
DN 1600 (66“)
DN 1800 (72“)
DN 2000 (78“)
8P
8T
8Y
to ANSI B16.5
class 150 (1“ ... 24“)

J
to AWWA C-207
Class D (28“ ... 78“)1)
L
to AS 4087
PN 16 (DN 50 ... 1200 (2" ... 48"))
N
to JIS
B 2220:2004 K10 (1" ... 24")
R
Flange material and coating
1
4
Liner material
Ebonite Hard Rubber

4
Electrode material

Hastelloy
3/100
Siemens FI 01 · 2016
MAG 6000, Polyamid, 11 ... 30 V DC/11 ... 24V AC
MAG 6000, Polyamid, 115 ... 230 V AC
MAG 5000, Polyamid, 11 ... 30 V DC/11 ... 24V AC
MAG 5000, Polyamid, 115 ... 230 V AC
Communication
No communication, add-on possible
HART
PROFIBUS PA Profile 3 (only MAG 6000)
PROFIBUS DP Profile 3 (only MAG 6000)
Modbus RTU/RS 485 (only MAG 6000)
FOUNDATION Fieldbus H1 (only MAG 6000)




H
J
K
L








A
B
F
G
E
J
1
2
DN 1400 to DN 2000 (54" to 78") do not conform to PED.
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.

Carbon steel flanges ASTM A 105, 150 m coating 
Carbon steel flanges ASTM A 105, 300 m coating
A
1)
A
B
C
D
F



Cable glands/terminal box
Metric
½" NPT
Flange norm and pressure rating
to EN 1092-1
PN 6 (DN 1400 ... 2000 (54“ ... 78“))1)
PN 10 (DN 200 ... 2000 (8“ ... 78“))1)
PN 16 (DN 65 ... 600 (2½“ ... 24“))
PN 16, non-PED (DN 700 ... 2000 (28“ ... 78“))
PN 40 (DN 25 ... 50 (1“ ... 2“))
Sensor for remote transmitter (Order transmitter
separately)
2
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
Order code
Selection and Ordering data
Operating instructions for SITRANS F M MAG 5100 W
Additional information
Description
Article No.
Please add “-Z“ to Article No. and specify Order
code(s) and plain text.
• German
• English
A5E03376527
A5E03063678
Pressure test certificate according to EN 10204-3.1
C01
Material certificate according to EN 10204-3.1
C121)
Factory certificate according to EN 10204-2.2
C14
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Factory certificate according to EN 10204-2.1
C15
Accessories
This device is shipped with a Quick Start guide and a CD containing
further SITRANS F literature.
,
Special calibration
Description
2002)
• 5-point calibration for DN 15 ... DN
• 5-point calibration for DN 250 ... DN 6002)
• 5-point calibration for DN 700 ... DN 12002)
D01
D02
D03
• 10-point calibration for DN 15 ... DN 2003)
• 10-point calibration for DN 250 ... DN 6003)
• 10-point calibration for DN 700 ... DN 12003)
D06
D07
D08
• Default (2 x 25 % and 2 x 90 %) match-pair calibration
for DN 15 ... DN 200
• Default (2 x 25 % and 2 x 90 %) match-pair calibration
for DN 250 ... DN 600
• Default (2 x 25 % and 2 x 90 %) match-pair calibration
for DN 700 ... DN 1200
D11
• 5-point, matched-pair calibration for
DN 15 ... DN 2002)
• 5-point, matched-pair calibration for
DN 250 ... DN 6002)
• 5-point, matched-pair calibration for
DN 700 ... DN 12002)
D15
• 10-point, matched-pair calibration for
DN 15 ... DN 2003)
• 10-point, matched-pair calibration for
DN 250 ... DN 6003
• 10-point, matched-pair calibration for
DN 700 ... DN 12003)
D18
Terminal blocks
• Factory mounted terminal blocks
D12
D13
Potting kit for terminal box
of flow sensors for
IP68/NEMA 6P
3
Article No.
 FDK:085U0220
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
MAG 5000/6000 transmitters and sensors are packed in separate boxes, the final assembly takes place during installation at
the customer's place.
Communication module will be pre-mounted in the transmitter.
Please use online Product selector to get latest updates.
Product selector link: www.pia-portal.automation.siemens.com
D16
D17
D19
D20
N02
Region specific approvals and certificates
• Chinese label translation
W06
Tag name plate, stainless steel fixed with SS wire
Y17
Tag name plate, plastic (self-adhesive)
Y18
Customer-specific converter setup
Y20
Sensor cables wired (specify cable Article No.)
Y40
Sensor for remote transmitter's junction box potted to
IP68 with wired cable (specify cable Article No.)
Y41
Other postproduction requirements (add desired text)
Y99
1)
Under preparation
2)
20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax
3)
Ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory
Qmax
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Siemens FI 01 · 2016
3/101
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
■ Dimensional drawings
155 (6.10)
155 ( 6.10)
178 (7.01)
M20
(½” NPT)
M20
(½” NPT)
D1
D1
D1
A
A
M20
(½” NPT)
A
3
178 (7.01)
178 (7.01)
155 (6.10)
L
7ME6520: DN 15 ... 40 (½" ... 1½")
L
L
7ME6520: DN 50 ... 300 (2" ... 12")
7ME6520: DN 350 ... 1200 (14" ... 48")
7ME6580: DN 25 ... 2000 (1" ... 78")
7ME6520 NBR or EPDM liner
Nominal size A
[mm]
15
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
1200
1400
1500
1600
1800
2000
1)
[inch]
½
1
1½
2
2½
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
42
44
48
54
60
66
72
78
[mm]
177
187
202
188
194
200
207
217
232
257
284
310
382
407
438
463
514
564
591
616
663
714
714
765
820
-
7ME6580 Ebonite liner
D1
[inch]
7.0
7.4
8.0
7.4
7.6
7.9
8.1
8.5
9.1
10.1
11.2
12.2
15.0
16.0
17.2
18.2
20.2
22.2
23.3
24.3
26.1
28.1
28.1
30.1
32.3
-
[mm]
77
96
127
76
89
102
114
140
168
219
273
324
451
502
563
614
715
816
869
927
1032
1136
1136
1238
1348
-
A
[inch]
3.0
3.8
5.0
3.0
3.5
4.0
4.5
5.5
6.6
8.6
10.8
12.8
17.8
19.8
22.2
24.2
28.2
32.1
34.2
36.5
40.6
44.7
44.7
48.7
53.1
-
[mm]
187
197
205
212
222
242
255
276
304
332
357
362
387
418
443
494
544
571
606
653
704
704
755
810
925
972
1025
1123
1223
L1)
D1
[inch]
7.4
7.8
8.1
8.3
8.7
9.5
10.0
10.9
12.0
13.1
14.1
14.3
15.2
16.5
17.4
19.4
21.4
22.5
23.9
25.7
27.7
27.7
29.7
31.9
36.4
38.2
40.4
44.2
48.1
[mm]
104
124
139
154
174
214
239
282
338
393
444
451
502
563
614
715
816
869
927
1032
1136
1136
1238
1348
1574
1672
1774
1974
2174
[inch]
4.09
4.88
5.47
6.06
6.85
8.43
9.41
11.1
13.31
15.47
17.48
17.76
19.76
22.16
24.17
28.15
32.13
34.21
36.5
40.63
44.72
44.72
48.74
53.07
65.94
65.83
75.39
77.72
85.59
Tolerances on build in length:
DN 15 to DN 200 (½" to 8"): +0/-3 mm (+0/-0.12"), DN 250 to DN 400 (10" to 16"): +0/-5 mm (+0/-0.20"),
DN 450 to DN 600 (18" to 24"): +5/-5 mm (+0.20/-0.20"), DN 700 to DN 2000 (28" to 78"): +10/-10 mm (+0.39/-0.39")
- not available
3/102
Siemens FI 01 · 2016
[mm]
200
200
200
200
200
200
250
250
300
350
450
500
550
600
600
600
600
700
750
800
900
1000
1000
1100
1200
1400
1500
1600
1800
2000
[inch]
7.9
7.9
7.9
7.9
7.9
7.9
9.8
9.8
11.8
13.8
17.7
19.7
21.7
23.6
23.6
23.6
23.6
27.6
29.5
31.5
35.4
39.4
39.4
43.3
47.2
55.1
59.1
63
70.9
78.7
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
MAG 5100 W/6000 I Compact
208 (8.19)
208 (8.19)
2 x M25
155 (6.10)
208 (8.19)
2 x M25
155 (6.10)
M20
(½” NPT)
M20
(½” NPT)
3
A1
D1
D1
D1
A
A
A
A1
A1
M20
(½” NPT)
2 x M25
155 (6.10)
L
7ME6520: DN 15 ... 40 (½" ... 1½")
L
L
7ME6520: DN 50 ... 300 (2" ... 12")
7ME6520: DN 350 ... 2000 (14" ... 78")
7ME6580: DN 25 ... 2000 (1" ... 78")
7ME6520 NBR or EPDM liner
[mm] [inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
15
25
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
700
750
800
900
1000
177
187
202
188
194
200
207
217
232
257
284
310
382
407
438
463
514
564
591
616
663
714
714
765
820
-
7.0
7.4
8.0
7.4
7.6
7.9
8.1
8.5
9.1
10.1
11.2
12.2
15.0
16.0
17.2
18.2
20.2
22.2
23.3
24.3
26.1
28.1
28.1
30.1
32.3
-
331
341
356
342
348
354
361
371
386
411
438
464
536
561
592
617
668
718
745
770
817
868
868
919
974
-
13.0
13.4
14.0
13.5
13.7
14.0
14.2
14.6
15.2
16.2
17.2
18.3
21.1
22.1
23.3
24.3
26.3
28.3
29.3
30.3
32.2
34.2
34.2
36.2
38.3
-
77
96
127
76
89
102
114
140
168
219
273
324
451
502
563
614
715
816
869
927
1032
1136
1136
1238
1348
-
3.0
3.8
5.0
3.0
3.5
4.0
4.5
5.5
6.6
8.6
10.8
12.8
17.8
19.8
22.2
24.2
28.2
32.1
34.2
36.5
40.6
44.7
44.7
48.7
53.1
-
187
187
197
205
212
222
242
255
276
304
332
357
362
387
418
443
494
544
571
606
653
704
704
755
810
925
972
1025
1123
1223
7.4
7.4
7.8
8.1
8.3
8.7
9.5
10.0
10.9
12.0
13.1
14.1
14.3
15.2
16.5
17.4
19.4
21.4
22.5
23.9
25.7
27.7
27.7
29.7
31.9
36.4
38.2
40.4
44.2
48.1
341
351
359
366
376
396
409
430
458
486
511
516
541
572
597
648
698
725
760
807
858
858
904
964
1079
1126
1179
1277
1377
13.4
13.8
14.1
14.4
14.8
15.6
16.1
16.9
18.0
19.1
20.1
20.3
21.3
22.5
23.5
25.5
27.5
28.5
29.9
31.8
33.8
33.8
35.6
38.0
42.5
44.3
46.4
50.3
54.2
104
124
139
154
174
214
239
282
338
393
444
451
502
563
614
715
816
869
927
1032
1136
1136
1238
1348
1574
1672
1774
1974
2174
4.09
4.88
5.47
6.06
6.85
8.43
9.41
11.1
13.31
15.47
17.48
17.76
19.76
22.16
24.17
28.15
32.13
34.21
36.5
40.63
44.72
44.72
48.74
53.07
61.97
65.83
69.84
77.72
85.59
200
200
200
200
200
200
250
250
300
350
450
500
550
600
600
600
600
700
750
800
900
1000
1000
1100
1200
1400
1500
1600
1800
2000
7.9
7.9
7.9
7.9
7.9
7.9
9.8
9.8
11.8
13.8
17.7
19.7
21.7
23.6
23.6
23.6
23.6
27.6
29.5
31.5
35.4
39.4
39.4
43.3
47.2
55.1
59.1
63.0
70.9
78.7
1200
1400
1500
1600
1800
2000
1)
D1
A
A1
L1)
A
½
1
1½
2
2½
3
4
5
6
8
10
12
14
16
18
20
24
28
30
32
36
40
42
44
48
54
60
66
72
78
A1
7ME6580 Ebonite liner
Nominal size
D1
Tolerances on build in length:
DN 15 to DN 200 (½" to 8"): +0/-3 mm (+0/-0.12"), DN 250 to DN 400 (10" to 16"): +0/-5 mm (+0/-0.20"),
DN 450 to DN 600 (18" to 24"): +5/-5 mm (+0.20/-0.20"), DN 700 to DN 2000 (28" to 78"): +10/-10 mm (+0.39/-0.39")
- not available
Siemens FI 01 · 2016
3/103
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 5100 W
Weight
7ME6520
NBR or EPDM liner
3
7ME6580
Ebonite liner
Nominal size
PN 10
Class 150/AWWA
AS
[mm]
[inch]
[kg]
[lb]
PN 16
[kg]
[lb]
PN 40
[kg]
[lb]
[kg]
[lb]
[kg]
[lb]
PN 16
[kg]
[lb]
15
½
-
-
-
-
4
9
4
9
4
9
5
11
25
1
-
-
-
-
6
12
5
11
4
9
5
11
40
1½
-
-
-
-
8
18
7
15
7
15
8
17
50
2
-
-
9
20
-
-
8
20
9
20
9
20
65
2½
-
-
10.7
24
-
-
11
24
10.7
24
11
24
80
3
-
-
11.6
26
-
-
13
28
11.6
26
12
26
100
4
-
-
15.2
33
-
-
19
41
15.2
33
16
35
125
5
-
-
20.4
45
-
-
24
52
-
-
19
42
150
6
-
-
26
57
-
-
29
64
26
57
27
60
200
8
48
106
48
106
-
-
56
124
48
106
40
88
250
10
64
141
69
152
-
-
79
174
69
152
60
132
300
12
76
167
86
189
-
-
110
243
86
189
80
176
350
14
104
229
125
274
-
-
139
307
115
254
110
242
400
16
119
263
143
314
-
-
159
351
125
277
125
275
450
18
136
299
173
381
-
-
182
400
141
311
175
385
500
20
163
359
223
491
-
-
225
495
189
418
200
440
600
24
236
519
338
744
-
-
320
704
301
664
287
633
700
28
270
595
314
692
-
-
273
602
320
704
330
728
750
30
-
-
-
-
-
-
329
725
-
-
360
794
800
32
346
763
396
873
-
-
365
804
428
944
450
992
900
36
432
951
474
1043
-
-
495
1089
619
1362
530
1168
1000
40
513
1130
600
1321
-
-
583
1282
636
1399
660
1455
42
-
-
-
-
-
-
687
1512
-
-
-
-
44
-
-
-
-
-
-
763
1680
-
-
1140
2513
1200
48
643
1415
885
1948
-
-
861
1896
813
1789
1180
2601
1400
54
1592
3510
-
-
-
-
-
-
-
-
1600
3528
1500
60
-
-
-
-
-
-
-
-
-
-
2460
5423
1600
66
2110
4652
-
-
-
-
-
-
-
-
2525
5566
1800
72
2560
5644
-
-
-
-
-
-
-
-
2930
6460
2000
78
3640
8025
-
-
-
-
-
-
-
-
3665
8080
- not available
With transmitter MAG 5000 and MAG 6000 compact, weight is increased by approximately 0.8 kg (1.8 lb), with MAG 6000 I, weight is increased by 5.5 kg
(12.1 lb).
3/104
Siemens FI 01 · 2016