© Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W ■ Overview ■ Application The main applications of the SITRANS F M electromagnetic flow sensors can be found in the following fields: • Water abstraction • Water treatment • Water distribution network (leak detection management) • Custody transfer water meters • Irrigation • Waste water treatment • Filtration plant (e.g. reverse osmosis and ultra filtration) • Industrial water applications 3 ■ Mode of operation The flow measuring principle is based on Faradays law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to the velocity of the flow. ■ Integration The complete flowmeter consists of a flow sensor and an associated transmitter SITRANS F M MAG 5000, MAG 6000 or MAG 6000 I. The SITRANS F M MAG 5100 W is an electromagnetic flow sensor designed to meet ground water, drinking water, waste water, sewage or sludge applications. ■ Benefits • DN 15 to DN 1200 / 2000 (½” to 48"/78”) • Stock program of MAG 5100 W secures short delivery time • Connection flanges EN 1092-1 (DIN 2501), ANSI, AWWA, AS and JIS. • NBR Hard Rubber and Ebonite Hard Rubber liner for all water applications • EPDM liner with drinking water approvals • Hastelloy integrated grounding and measuring electrodes • Increased low flow accuracy for water leak detection, due to coned liner design (Article No. 7ME6520, DN 15 to 300 mm (½" to 12")). • Drinking water approvals • Suitable for direct burial and constant flooding • Custody transfer approvals • Build-in length according to ISO 13359; the standard includes sizes up to DN 400. • Easy commissioning, SENSORPROM unit automatically uploads calibration values and settings. • Designed so patented in-situ verification can be conducted. Using SENSORPROM fingerprint. • Custody transfer option for water billing, with type approval after OIML R 49 and verified according to MI-001 - 0D inlet/ 0D outlet installation - pattern approval OIML R 49 (Denmark, Germany) - conform to ISO 4064 and EN 14154 for mechanical flowmeters - PTB K7.2 - Kiwa water approval • FM Fire Service Meter (Class Number 1044) for automatic fire protection systems • Meets EEC directives: PED, 2014/68/EU pressure directive for EN1092-1 flanges • Simple onsite or factory upgrade to IP68/NEMA 6P of a standard sensor • MCERTS approval for UK environmental market 3/92 Siemens FI 01 · 2016 The flexible communication concept USM II simplifies integration and update to a variety of fieldbus systems, e.g. HART, DeviceNet, PROFIBUS DP and PA, FOUNDATION Fieldbus H1 or Modbus RTU/RS 485. © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W ■ Technical specifications Product characteristic MAG 5100 W (7ME6520) Mainly for the European market MAG 5100 W (7ME6580) Mainly for the non-European market EPDM or NBR lining Ebonite lining Design and nominal size Coned sensor (octagon liner): DN 15 ... 40 (½” ... 1½”) Coned sensor: DN 50 ... 300 (2” ... 12”) Full bore sensor: DN 350 ... 1200 (14” ... 48”) Full bore sensor: DN 25 ... 2000 (1” ... 78”) Measuring principle Electromagnetic induction Electromagnetic induction Excitation frequency (Mains supply: 50/60 Hz) DN 15 ... 65 (½” ... 2½”): 12.5 Hz/15 Hz DN 80 ... 150 (3” ... 6”): 6.25 Hz/7.5 Hz DN 200 ... 300 (8” ... 12”): 3.125 Hz/3.75 Hz DN 350 ... 1200 (14” ... 48”): 1.5625 Hz/1.875 Hz DN 25 ... 65 (1” ... 2½”): 12.5 Hz/15 Hz DN 80 ... 150 (3” ... 6”): 6.25 Hz/7.5 Hz DN 200 ... 1200 (8” ... 48”): 3.125 Hz/3.75 Hz DN 1400 ... 2000 (54” ... 78”): 1.5625 Hz/1.875 Hz • EN 1092-1 PN 10 (145 psi) : DN 200 ... 300 (8” ... 12”) Flat face PN 10 (145 psi): DN 350 ... 1200 (14” ... 48”) Raised face2) PN 16 (232 psi): DN 50 ... 300 (2” ... 12”) Flat face3) PN 16 (232 psi): DN 350 ... 1200 (14” ... 48”) Raised face PN 40 (580 psi): DN 15 ... 40 (½” ... 1½”) Flat face Raised face3) (EN 1092-1, DIN 2501 and BS 4504 have the same mating dimensions) PN 6 (87 psi): DN 1400 ... 2000 (54” ... 78”) PN 10 (145 psi): DN 200 ... 2000 (8” ... 78”) PN 16 (232 psi): DN 65 ... 600 (2½” ... 24”) PN 40 (580 psi): DN 25 ... 50 (1” ... 2”) • ANSI B16.5 Class 150: ½" ... 12" flat face; 14" ... 24" raised face Class 150: 1” ... 24”; raised face • AWWA C-207 Class D: 28” ... 48”, flat face Class D: 28” ... 78”, flat face • AS4087 PN 16 (DN 50 ... 1200), (2" ... 48") 16 bar (232 psi) PN 16 (DN 50 ... 1200), (2" ... 48") 16 bar (232 psi) • JIS B 2220:2004 - K10 (1" ... 24") Process connection Flanges1) Rated Operation conditions Ambient temperature • Sensor -40 ... +70 °C (-40 ... +158 °F) -20 ... +70 °C (-4 ... +158 °F) • With compact transmitter MAG 5000/60004) -20 ... +60 °C (-4 ... +140 °F) -20 ... +60 °C (-4 ... +140 °F) Operating pressure (Abs) [abs. bar] (Maximum operating pressure depending on flange standard, decreases with increasing operating temperature) DN 15 ... 40 (½” ... 1½”): 0.01 ... 40 bar (0.15 ... 580 psi) DN 50 ... 300 (2” ... 12”): 0.03 ... 20 bar (0.44 ... 290 psi) DN 350 ... 1200 (14” ... 48”): 0.01 ... 16 bar (0.15 ... 232 psi) DN 25 ... 50 (1” ... 2”): 0.01 ... 40 bar (0.15 ... 580 psi) DN 65 ... 1200 (2½” ... 48”): 0.01 ... 16 bar (0.15 ... 232 psi) DN 1400 ... 2000 (54” ... 78”): 0.01 ... 10 bar (0.15 ... 145 psi) • Standard IP67 to EN 60529/NEMA 4X/6 (1 mH2O for 30 min) IP67 to EN 60529/NEMA 4X/6 (1 mH2O for 30 min) • Option IP68 to EN 60529/NEMA 6P (10 mH2O continuously) IP68 to EN 60529/NEMA 6P (10 mH2O continuously) Pressure drop DN 15 and 25 (½" and 1"): Max. 20 mbar (0.29 psi) Insignificant at 1 m/s (3 ft/s). DN 40 ... 300 (1½" ... 12"): Max 25 mbar (0.36 psi) at 3 m/s (10 ft/s) DN 350 ... 1200 (14” ... 48”): Insignificant Test pressure 1.5 x PN (where applicable) FM Fire Service: 2 x PN 1.5 x PN (where applicable) Mechanical load (vibration) 18 ... 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36 Sensor: 3.17 g RMS Sensor with compact MAG 5000/6000 mounted transmitter: 3.17 g RMS Sensor with compact MAG 6000 I mounted transmitter: 1.14 g RMS 18 ... 1000 Hz random in x, y, z, directions for 2 hours according to EN 60068-2-36 Sensor: 3.17 g RMS Sensor with compact MAG 5000/6000 mounted transmitter: 3.17 g RMS Sensor with compact MAG 6000 I mounted transmitter: 1.14 g RMS Enclosure rating Siemens FI 01 · 2016 3/93 3 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W Product characteristic Mainly for the European market (7ME6520) Mainly for the non-European market (7ME6580) EPDM or NBR lining Ebonite lining Medium conditions Temperature of medium 3 • NBR -10 ... +70 °C (14 ... 158 °F) - • EPDM -10 ... +70 °C (14 ... 158 °F) - • EPDM/NBR (MI-001) 0.1 ... 30 °C (32 ... 76 °F) - • Ebonite - -10 ... +70 °C (14 ... 158 °F) EMC 2014/30/EU 2014/30/EU • Housing and flanges Carbon steel ASTM A 105, with corrosionresistant two-component epoxy coating (150 m/300 m) Corrosivity category C2+, according to ISO 12944-2 Carbon steel ASTM A 105, with corrosionresistant two-component epoxy coating (150 m/300 m) Corrosivity category C2+, according to ISO 12944-2 • Measuring pipe Stainless steel AISI 304/1.4301 Stainless steel AISI 304/1.4301 • Electrode Hastelloy C276 Hastelloy C276 • Grounding electrode Hastelloy C276 Hastelloy C276 • Terminal box Fibre glass reinforced polyamide Fibre glass reinforced polyamide • Standard production calibration (default), calibration report shipped with sensor Zero-point, 2 x 25 % and 2 x 90 % Zero-point, 2 x 25 % and 2 x 90 % • Special calibration 5-point calibration: 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 10-point calibration: ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax Matched-pair calibration: default, 5-point or 10point 5-point calibration: 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 10-point calibration: ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax Matched-pair calibration: default, 5-point or 10point Material certificate EN 10204 3.1 Available when ordering together with meter5) Available when ordering together with meter5) meter5) Available when ordering together with meter5) Design Material Certificates and approvals Calibration Pressure test certificate Available when ordering together with Custody transfer (only together with MAG 6000 CT) OIML R 49 pattern approval cold water (Denmark and Germany): DN 50 ... DN 300 (2“ ... 12") MI-001 cold water (EU): DN 50 ... DN 1200 (2“ ... 48") PTB K7.2: Chilled water energy metering DN 50-300 (order as special) Certificate number: 22 76.10 02 Kiwa water approval: DN 50 ... DN 1200 (2" ... 48") Drinking water approvals EPDM liner: NSF/ANSI Standard 616) (Cold water, US) WRAS (WRc, BS6920 cold water, GB) ACS (F), DVGW W270 (D), Belgaqua (B) Other approvals MCERTS PED conforming: All EN1092-1 flanges and ANSI Class 150 (< DN 300 (<12”)) – 2014/68/EU7) CMC/CPA CSA Class I, Div 28) FM Class I, Div 28) FM Fire Service Approval according to class 10448)9) VdS: Extinguishing systems DN 50 ... DN 300 1) 2) 3) 4) 5) 6) NSF/ANSI Standard 616) (Cold water, US) WRAS (WRc, BS6920 cold water, GB) PED conforming: All EN1092-1 flanges ( DN 600 ( 24") – 2014/68/EU7) CMC/CPA CSA Class I, Div 28) FM Class I, Div 28) DN 750, DN 1050 and DN 1100 (30", 42" and 44") not available with EN 1092-1 (PN 10 and PN 16) and AS4087 flanges Type 01 (SORF) DN 600 type 01 (SORF); DN > 600 type 11 With compact transmitter MAG 5000 CT/6000 CT -20 ... +50 °C (-4 ... +122 °F); with compact MI-001 approved transmitter -25 ... +55 ºC (-13 ... +131 ºF) Has to be ordered with the meter. It is not possible to order the certificate afterwards. Including Annex G For sizes larger than 600 mm (24”) in PN 16 PED conformity is available as a cost-added option. The basic unit will carry the LVD (Low Voltage Directive) and EMC approval. All products sold outside of EU and EFTA are excluded from the directive, also products sold into certain market sectors are excluded. These include: a) Meters used in networks for the supply, distribution and discharge of water. b) Meters used in pipelines for the conveyance of any fluid from offshore to onshore. c) Meters used in the extraction of petroleum or gas, including Christmas tree and manifold equipment. d) Any meter mounted on a ship or mobile offshore platform. For further information on the PED standard and requirements see page 9/6. 8) Not for sensors with 300 m coating. 9) DN 50, DN 80, DN 100, DN 150, DN 200, DN 250, and DN 300 (2", 3", 4", 6", 8", 10", and 12") with ANSI B16.5 Class 150 flanges 7) 3/94 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W MAG 5100 W (7ME6520) with MAG 6000 CT (Revenue program) MI-001 MAG 5100 W (7ME6520) with MAG 5000/MAG 6000 or MAG 6000 CT for Fire Service applications MAG 5100 W CT program is type approved according to international water meter standard OIML R 49. Since the first November 2006 the MI-001 water meter directive is in force, which means that all water meters can be sold across the EU borders if the water meters contain a MI-001 label. The MAG 5100 W MI-001 verified and labeled products are a Class II approval according to Directive 2014/32/EU of the European Parliament and Council of 26 February, 2014 on measuring instruments, Annex VI Thermal Energy Meters (MI-004) in the sizes from DN 50 to DN 1200 (Article No. 7ME6520). The MID certification is obtained as a modul B + D module approval according to the above mentioned directive. Module B : Type approval according to OIML R 49 Module D : Quality insurance approval of production MAG 5100 W (7ME6520) is FM Fire Service approved for automatic fire protection systems. The approval is applicable for the sizes DN 50, DN 80, DN 100, DN 150, DN 200, DN 250 and DN 300 (2", 3", 4", 6", 8", 10" and 12") with ANSI B16.5 Class 150 flanges. The FM Fire Service approved product can be ordered via the Z-options P20, P21 and P22. ±E% FM Fire Service verification tolerances 3 1.5 % MI-001 verification tolerances ±E% Qmin Cl. II = 5% Qmax Cl. II = 2% Q1 Q2 Q3 Q4 Siemens FI 01 · 2016 3/95 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W MAG 5100 W (7ME6520) MI-001 verified and labeled products at a given Q3 and Q3/Q4 = 1.25 and Q2/Q1 = 1.6 measuring ranges see table below: 3 Order code: P11 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“) „R“ Q3/Q1 25 25 25 25 25 25 25 25 25 Q4 [m3/h] 20 31.25 50 78.75 125 200 312.5 500 787.5 Q3 [m3/h] 16 25 40 63 100 160 250 400 630 Q2 [m3/h] 1.02 1.6 2.6 4.0 6.4 10.2 16 25.6 40.3 Q1 [m3/h] 0.64 1.00 1.60 2.52 4.0 6.4 10.0 16.0 25.2 Order code: P12 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“) „R“ Q3/Q1 63 63 63 63 63 63 63 63 63 [m3/h] 20 31.25 50 78.75 125 200 312.5 500 787.5 Q3 [m3/h] 16 25 40 63 100 160 250 400 630 Q2 [m3/h] 0.41 0.63 1.02 1.6 2.5 4.1 6.3 10.2 16.0 Q1 [m3/h] 0.25 0.40 0.63 1.00 1.59 2.54 3.97 6.35 10.0 Order code: P13 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“) „R“ Q3/Q1 80 80 80 80 80 80 80 80 80 Q4 [m3/h] 20 31.3 50 78.75 125 200 313 500 1250 Q3 [m3/h] 16 25 40 63 100 160 250 400 1000 Q2 [m3/h] 0.32 0.5 0.8 1.3 2.0 3.2 5.0 8.0 20.0 Q1 [m3/h] 0.20 0.31 0.50 0.79 1.25 2.00 3.13 5.00 12.50 Order code: P16 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“) „R“ Q3/Q1 160 160 160 160 160 160 160 160 160 Q4 [m3/h] 78.75 125 200 313 500 788 1250 2000 2000 Q4 Q3 [m3/h] 63 63 160 250 400 400 1000 1600 1600 Q2 [m3/h] 0.63 1.0 1.6 2.5 4.0 6.3 10.0 16.0 16.0 Q1 [m3/h] 0.39 0.63 1.00 1.56 2.50 3.94 6.25 10.00 10.00 Order code: P17 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“) „R“ Q3/Q1 200 200 200 200 200 200 200 200 200 Q4 [m3/h] 78.75 125 200 313 500 788 1250 2000 2000 Q3 [m3/h] 63 100 160 250 400 630 1000 1600 1600 Q2 [m3/h] 0.50 0.80 1.3 2.0 3.2 5.0 8.0 12.8 12.8 [m3/h] 0.32 0.50 0.80 1.25 2.00 3.15 5.00 8.00 8.00 Q1 Order code: P18 DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 (4“) DN 125 (5“) DN 150 (6“) DN 200 (8“) DN 250 (10“) DN 300 (12“) „R“ Q3/Q1 250 250 250 250 250 250 250 250 250 Q4 [m3/h] 78.75 125 200 313 500 788 1250 2000 2000 Q3 [m3/h] 63 100 160 250 400 630 1000 1600 1600 Q2 [m3/h] 0.4 0.64 1.0 1.6 2.6 4.0 6.4 10.2 10.2 Q1 [m3/h] 0.25 0.40 0.64 1.00 1.60 2.52 4.00 6.40 6.40 Order code: P24 DN 350 (14") DN 400 (16“) DN 450 (18“) DN 500 (20“) DN 600 (24“) „R“ Q3/Q1 25 25 25 25 25 Q4 [m3/h] 1250 1250 1250 2000 3125 Q3 [m3/h] 1000 1000 1000 1600 2500 Q2 [m3/h] 64 64 64 102 160 Q1 [m3/h] 40 40 40 64 100 Order code: P25 DN 350 (14") DN 400 (16“) DN 450 (18“) DN 500 (20“) DN 600 (24“) „R“ Q3/Q1 63 63 63 63 63 Q4 [m3/h] 1250 1250 3125 3125 5000 Q3 [m3/h] 1000 1000 2500 2500 4000 Q2 [m3/h] 25 25 63 63 102 Q1 [m3/h] 15.9 15.9 39.7 39.7 63.5 3/96 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W Order code: P26 DN 350 (14") DN 400 (16“) DN 450 (18“) DN 500 (20“) DN 600 (24“) „R“ Q3/Q1 80 80 80 80 80 Q4 [m3/h] 2000 2000 3125 3125 5000 Q3 [m3/h] 1600 1600 2500 2500 4000 Q2 [m3/h] 32 32 50 50 80 Q1 [m3/h] 20 20 31.25 31.3 50 Order code: P27 DN 350 (14") DN 400 (16“) DN 450 (18“) DN 500 (20“) DN 600 (24“) „R“ Q3/Q1 160 160 160 160 160 Q4 [m3/h] 2000 3125 3125 5000 7875 Q3 [m3/h] 1600 4000 4000 6300 6300 Q2 [m3/h] 16 25 25 40 63 Q1 [m3/h] 10.00 15.63 15.63 25.00 39.38 Order code: P29 DN 700 (28“) DN 750 (30“) DN 800 (32“) DN 900 (36“) DN 1000 (40“) DN 1200 (48“) „R“ Q3/Q1 25 25 25 25 25 25 Q4 [m3/h] 5000 5000 5000 7875 7875 7875 Q3 [m3/h] 4000 4000 4000 6300 6300 6300 Q2 [m3/h] 256 256 256 403 403 403 Q1 [m3/h] 160 160 160 252 252 252 Order code: P30 DN 700 (28“) DN 750 (30“) DN 800 (32“) DN 900 (36“) DN 1000 (40“) DN 1200 (48“) „R“ Q3/Q1 63 63 63 63 63 - Q4 [m3/h] 5000 5000 5000 7875 7875 - Q3 [m3/h] 4000 4000 4000 6300 6300 - Q2 [m3/h] 102 102 102 160 160 - Q1 [m3/h] 63.5 63.5 63.5 100 100 - Order code: P31 DN 700 (28“) DN 750 (30“) DN 800 (32“) DN 900 (36“) DN 1000 (40“) DN 1200 (48“) „R“ Q3/Q1 80 80 80 80 - - Q4 [m3/h] 5000 5000 5000 7875 - - Q3 [m3/h] 4000 4000 4000 6300 - - Q2 [m3/h] 80 80 80 126 - - Q1 [m3/h] 50.0 50.0 50.0 78.8 - - The label is placed on the transmitter housing. An example of the product label is shown below: 3 OIML R 49/MI-001 approvals valid for: • DN 50 to DN 1200 (2" to 48"). As special requests (PVR) available up to DN 2000 (80") • Horizontal installation • Compact or remote with max. 500 m cable • Power supply 115 to 230 V AC, 12 to 24 V AC/DC • With or without communication module Other restrictions may apply (see certificate). Special OIML / MI-001 settings: • Unit: m3 • Qmax: Q3 • Digital output: Frequency For other factory settings, see Operating Instructions. Siemens FI 01 · 2016 3/97 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W Selection and Ordering data Article No. Order Code Selection and Ordering data Article No. Order Code Sensor SITRANS F M MAG 5100 W Hastelloy electrodes, carbon steel flanges, EU water markets and low flow applications 7 ME 6 5 2 0 - Sensor SITRANS F M MAG 5100 W Hastelloy electrodes, carbon steel flanges, EU water markets and low flow applications 7 ME 6 5 2 0 - 77777 - 2 777 777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Transmitter Sensor for remote transmitter (Order trans- mitter separately) MAG 6000 I, Aluminum, 18 ... 90 V DC, 115 ... 230 V AC Diameter 3 DN 15 (½“) DN 25 (1“) DN 40 (1½“) DN 50 (2“) DN 65 (2½“) DN 80 (3“) DN 100 (4“) 3F 3M 3T DN 125 (5“) DN 150 (6“) DN 200 (8“) 4B 4H 4P DN 250 (10“) DN 300 (12“) DN 350 (14“) 4V 5D 5K DN 400 (16“) DN 450 (18“) DN 500 (20“) 5R 5Y 6F DN 600 (24“) DN 700 (28“) DN 750 (30“) 6P 6Y 7D DN 800 (32“) DN 900 (36“) DN 1000 (40“) 7H 7M 7R (42“) (44“) DN 1200 (48“) 7U 7V 8B 1V 2D 2R 2Y MAG 6000, Polyamid, 11 ... 30 V DC/11 ... 24 V AC MAG 6000, Polyamid, 115 ... 230 V AC MAG 5000, Polyamid, 11 ... 30 V DC/11 ... 24 V AC MAG 5000, Polyamid, 115 ... 230 V AC MAG 6000 CT, Polyamid, 115 ... 230 V AC MAG 6000 CT, Polyamid, 11 ... 30 V DC/11 ... 24 V AC Communication None HART PROFIBUS PA Profile 3 (only MAG 6000/ MAG 6000 I) PROFIBUS DP Profile 3 (only MAG 6000/ MAG 6000 I) Modbus RTU/RS 485 (only MAG 6000/ MAG 6000 I) FOUNDATION Fieldbus H1 (only MAG 6000/ MAG 6000 I) Cable glands/terminal box Metric/Polyamid terminal box or 6000 I compact ½" NPT/Polyamid terminal box or 6000 I compact B C D F to ANSI B16.5 class 150 (½“ ... 24“) J to AWWA C-207 Class D (28“ ... 48“) L to AS 4087 PN 16 (DN 50 ... 1200/2“ ... 48“) N Flange material and coating Carbon steel flanges ASTM A 105, 150 m coating Carbon steel flanges ASTM A 105, 300 m coating Liner material EPDM NBR Hard Rubber 3/98 Siemens FI 01 · 2016 A C H J K L M R A B F G E J 1 2 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Flange norm and pressure rating to EN 1092-1 PN 10 (DN 200 ... 1200/8“ ... 48“) PN 16 (DN 50 ... 1200/2“ ... 48“) PN 16, non PED (DN 700 ... 1200/28“ ... 48“) PN 40 (DN 15 ... 40/½“ ... 1½“) 77777 - 2 777 777 1 4 2 3 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W Selection and Ordering data Order code Order code Selection and Ordering data FM Fire Service Approval (with ANSI B16.5 Class 150 flanges) Additional information Please add “-Z“ to Article No. and specify Order code(s) and plain text. • DN 50, DN 80 and DN 100 (2", 3" and 4") P20 Pressure test certificate according to EN 10204-3.1 C01 • DN 150 and DN 200 (6" and 8") P21 Material certificate according to EN 10204-3.1 C12 • DN 250 and DN 300 (10" and 12") P22 Factory certificate according to EN 10204-2.2 C14 Y17 Factory certificate according to EN 10204-2.1 C15 Tag name plate, stainless steel fixed with SS wire (add plain text) FP2E marking (only France) C17 Tag name plate, plastic (self-adhesive) Y18 Customer-specific converter setup Y20 Sensor cables wired (specify cable Article No.) Y40 Sensor for remote transmitter's junction box potted to IP68 with wired cable (specify cable Article No.) Y41 Other postproduction requirements (add desired text) Y99 Region specific approvals and certificates • Chinese label translation • KCC label W06 W28 Special calibration 3 • 5-point calibration for DN 15 ... DN 2001) • 5-point calibration for DN 250 ... DN 6001) • 5-point calibration for DN 700 ... DN 12001) D01 D02 D03 Additional Calibrations Accredited Siemens Flow Instruments matched pair Calibration acc. to ISO/IEC 17025:2005 On request5) • 10-point calibration for DN 15 ... DN 2002) • 10-point calibration for DN 250 ... DN 6002) • 10-point calibration for DN 700 ... DN 12002) D06 D07 D08 Customer-witnessed calibration Any of above calibration On request5) 1) • Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 15 ... DN 200 • Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 250 ... DN 600 • Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 700 ... DN 1200 D11 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 2) D12 Ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 3) D13 For more details and references of the ranges please see the tables on page 3/96. 4) For remote version submit Product Variation Request. 5) • 5-point, matched-pair calibration for DN 15 ... DN 2001) • 5-point, matched-pair calibration for DN 250 ... DN 6001) • 5-point, matched-pair calibration for DN 700 ... DN 12001) D15 Ordering On request as dedicated information from the customer on the individual sensors is required. • 10-point, matched-pair calibration for DN 15 ... DN 2002) • 10-point, matched-pair calibration for DN 250 ... DN 6002) • 10-point, matched-pair calibration for DN 700 ... DN 12002) Terminal blocks • Factory mounted terminal blocks D16 Operating instructions for SITRANS F M MAG 5100 W D17 D18 D19 D20 N02 Description Article No. • English • German A5E03063678 A5E03376527 This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Accessories , Approval/Verification3) Description (MI-001 : DN 50 ... DN 300 (compact only), EN 1092-1 PN10 and PN16 flanges with MAG 6000 CT)4) Potting kit for terminal box of flow sensors for IP68/NEMA 6P • Without verification according to OIML R 49 (DN 50 ... DN 300) P10 • MI-001 Q3/Q1 = 25 (DN 50 ... DN 300) P11 • MI-001 Q3/Q1 = 63 (DN 50 ... DN 300) P12 • MI-001 Q3/Q1 = 80 (DN 50 ... DN 300) P13 • MI-001 Q3/Q1 = 160 (DN 50 ... DN 300) P16 • MI-001 Q3/Q1 = 200 (DN 50 ... DN 300) P17 • MI-001 Q3/Q1 = 250 (DN 50 ... DN 300) P18 • Without verification according to OIML R 49 (DN 350 ... DN 600) P23 • MI-001 Q3/Q1 = 25 (DN 350 ... DN 600) P24 • MI-001 Q3/Q1 = 63 (DN 350 ... DN 600) P25 • MI-001 Q3/Q1 = 80 (DN 350 ... DN 600) P26 • MI-001 Q3/Q1 = 160 (DN 350 ... DN 600) P27 • Without verification according to OIML R 49 (DN 700 ... DN 1200) P28 • MI-001 Q3/Q1 = 25 (DN 700 ... DN 1200) P29 • MI-001 Q3/Q1 = 63 (DN 700 ... DN 1200) P30 • MI-001 Q3/Q1 = 80 (DN 700 ... DN 1200) P31 Article No. FDK:085U0220 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. MAG 5000/6000 transmitters and sensors are packed in separate boxes, the final assembly takes place during installation at the customer's place. MAG 6000 I transmitters and sensors are delivered compact mounted from factory. Communication module will be pre-mounted in the transmitter. Please use online Product selector to get latest updates. Product selector link: www.pia-portal.automation.siemens.com Siemens FI 01 · 2016 3/99 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W Selection and Ordering data Article No. Selection and Ordering data Article No. Sensor SITRANS F M MAG 5100 W 7 ME 6 5 8 0 - Sensor SITRANS F M MAG 5100 W 7 ME 6 5 8 0 - Hastelloy electrodes, carbon steel flanges, Non EU water markets 77777 - 7777 Hastelloy electrodes, carbon steel flanges, Non EU water markets 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Transmitter with display Diameter 3 DN 25 (1“) DN 40 (1½“) DN 50 (2“) 2D 2R 2Y DN 65 (2½“) DN 80 (3“) DN 100 (4“) 3F 3M 3T DN 125 (5“) DN 150 (6“) DN 200 (8“) 4B 4H 4P DN 250 (10“) DN 300 (12“) DN 350 (14“) 4V 5D 5K DN 400 (16“) DN 450 (18“) DN 500 (20“) 5R 5Y 6F DN 600 (24“) DN 700 (28“) DN 750 (30“) 6P 6Y 7D DN 800 (32“) DN 900 (36“) DN 1000 (40“) 7H 7M 7R (42“) (44“) 7U 7V DN 1200 (48“) DN 1400 (54“) DN 1500 (60“) 8B 8F 8K DN 1600 (66“) DN 1800 (72“) DN 2000 (78“) 8P 8T 8Y to ANSI B16.5 class 150 (1“ ... 24“) J to AWWA C-207 Class D (28“ ... 78“)1) L to AS 4087 PN 16 (DN 50 ... 1200 (2" ... 48")) N to JIS B 2220:2004 K10 (1" ... 24") R Flange material and coating 1 4 Liner material Ebonite Hard Rubber 4 Electrode material Hastelloy 3/100 Siemens FI 01 · 2016 MAG 6000, Polyamid, 11 ... 30 V DC/11 ... 24V AC MAG 6000, Polyamid, 115 ... 230 V AC MAG 5000, Polyamid, 11 ... 30 V DC/11 ... 24V AC MAG 5000, Polyamid, 115 ... 230 V AC Communication No communication, add-on possible HART PROFIBUS PA Profile 3 (only MAG 6000) PROFIBUS DP Profile 3 (only MAG 6000) Modbus RTU/RS 485 (only MAG 6000) FOUNDATION Fieldbus H1 (only MAG 6000) H J K L A B F G E J 1 2 DN 1400 to DN 2000 (54" to 78") do not conform to PED. We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Carbon steel flanges ASTM A 105, 150 m coating Carbon steel flanges ASTM A 105, 300 m coating A 1) A B C D F Cable glands/terminal box Metric ½" NPT Flange norm and pressure rating to EN 1092-1 PN 6 (DN 1400 ... 2000 (54“ ... 78“))1) PN 10 (DN 200 ... 2000 (8“ ... 78“))1) PN 16 (DN 65 ... 600 (2½“ ... 24“)) PN 16, non-PED (DN 700 ... 2000 (28“ ... 78“)) PN 40 (DN 25 ... 50 (1“ ... 2“)) Sensor for remote transmitter (Order transmitter separately) 2 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W Order code Selection and Ordering data Operating instructions for SITRANS F M MAG 5100 W Additional information Description Article No. Please add “-Z“ to Article No. and specify Order code(s) and plain text. • German • English A5E03376527 A5E03063678 Pressure test certificate according to EN 10204-3.1 C01 Material certificate according to EN 10204-3.1 C121) Factory certificate according to EN 10204-2.2 C14 All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Factory certificate according to EN 10204-2.1 C15 Accessories This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. , Special calibration Description 2002) • 5-point calibration for DN 15 ... DN • 5-point calibration for DN 250 ... DN 6002) • 5-point calibration for DN 700 ... DN 12002) D01 D02 D03 • 10-point calibration for DN 15 ... DN 2003) • 10-point calibration for DN 250 ... DN 6003) • 10-point calibration for DN 700 ... DN 12003) D06 D07 D08 • Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 15 ... DN 200 • Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 250 ... DN 600 • Default (2 x 25 % and 2 x 90 %) match-pair calibration for DN 700 ... DN 1200 D11 • 5-point, matched-pair calibration for DN 15 ... DN 2002) • 5-point, matched-pair calibration for DN 250 ... DN 6002) • 5-point, matched-pair calibration for DN 700 ... DN 12002) D15 • 10-point, matched-pair calibration for DN 15 ... DN 2003) • 10-point, matched-pair calibration for DN 250 ... DN 6003 • 10-point, matched-pair calibration for DN 700 ... DN 12003) D18 Terminal blocks • Factory mounted terminal blocks D12 D13 Potting kit for terminal box of flow sensors for IP68/NEMA 6P 3 Article No. FDK:085U0220 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. MAG 5000/6000 transmitters and sensors are packed in separate boxes, the final assembly takes place during installation at the customer's place. Communication module will be pre-mounted in the transmitter. Please use online Product selector to get latest updates. Product selector link: www.pia-portal.automation.siemens.com D16 D17 D19 D20 N02 Region specific approvals and certificates • Chinese label translation W06 Tag name plate, stainless steel fixed with SS wire Y17 Tag name plate, plastic (self-adhesive) Y18 Customer-specific converter setup Y20 Sensor cables wired (specify cable Article No.) Y40 Sensor for remote transmitter's junction box potted to IP68 with wired cable (specify cable Article No.) Y41 Other postproduction requirements (add desired text) Y99 1) Under preparation 2) 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax 3) Ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Siemens FI 01 · 2016 3/101 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W ■ Dimensional drawings 155 (6.10) 155 ( 6.10) 178 (7.01) M20 (½” NPT) M20 (½” NPT) D1 D1 D1 A A M20 (½” NPT) A 3 178 (7.01) 178 (7.01) 155 (6.10) L 7ME6520: DN 15 ... 40 (½" ... 1½") L L 7ME6520: DN 50 ... 300 (2" ... 12") 7ME6520: DN 350 ... 1200 (14" ... 48") 7ME6580: DN 25 ... 2000 (1" ... 78") 7ME6520 NBR or EPDM liner Nominal size A [mm] 15 25 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 1200 1400 1500 1600 1800 2000 1) [inch] ½ 1 1½ 2 2½ 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 42 44 48 54 60 66 72 78 [mm] 177 187 202 188 194 200 207 217 232 257 284 310 382 407 438 463 514 564 591 616 663 714 714 765 820 - 7ME6580 Ebonite liner D1 [inch] 7.0 7.4 8.0 7.4 7.6 7.9 8.1 8.5 9.1 10.1 11.2 12.2 15.0 16.0 17.2 18.2 20.2 22.2 23.3 24.3 26.1 28.1 28.1 30.1 32.3 - [mm] 77 96 127 76 89 102 114 140 168 219 273 324 451 502 563 614 715 816 869 927 1032 1136 1136 1238 1348 - A [inch] 3.0 3.8 5.0 3.0 3.5 4.0 4.5 5.5 6.6 8.6 10.8 12.8 17.8 19.8 22.2 24.2 28.2 32.1 34.2 36.5 40.6 44.7 44.7 48.7 53.1 - [mm] 187 197 205 212 222 242 255 276 304 332 357 362 387 418 443 494 544 571 606 653 704 704 755 810 925 972 1025 1123 1223 L1) D1 [inch] 7.4 7.8 8.1 8.3 8.7 9.5 10.0 10.9 12.0 13.1 14.1 14.3 15.2 16.5 17.4 19.4 21.4 22.5 23.9 25.7 27.7 27.7 29.7 31.9 36.4 38.2 40.4 44.2 48.1 [mm] 104 124 139 154 174 214 239 282 338 393 444 451 502 563 614 715 816 869 927 1032 1136 1136 1238 1348 1574 1672 1774 1974 2174 [inch] 4.09 4.88 5.47 6.06 6.85 8.43 9.41 11.1 13.31 15.47 17.48 17.76 19.76 22.16 24.17 28.15 32.13 34.21 36.5 40.63 44.72 44.72 48.74 53.07 65.94 65.83 75.39 77.72 85.59 Tolerances on build in length: DN 15 to DN 200 (½" to 8"): +0/-3 mm (+0/-0.12"), DN 250 to DN 400 (10" to 16"): +0/-5 mm (+0/-0.20"), DN 450 to DN 600 (18" to 24"): +5/-5 mm (+0.20/-0.20"), DN 700 to DN 2000 (28" to 78"): +10/-10 mm (+0.39/-0.39") - not available 3/102 Siemens FI 01 · 2016 [mm] 200 200 200 200 200 200 250 250 300 350 450 500 550 600 600 600 600 700 750 800 900 1000 1000 1100 1200 1400 1500 1600 1800 2000 [inch] 7.9 7.9 7.9 7.9 7.9 7.9 9.8 9.8 11.8 13.8 17.7 19.7 21.7 23.6 23.6 23.6 23.6 27.6 29.5 31.5 35.4 39.4 39.4 43.3 47.2 55.1 59.1 63 70.9 78.7 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W MAG 5100 W/6000 I Compact 208 (8.19) 208 (8.19) 2 x M25 155 (6.10) 208 (8.19) 2 x M25 155 (6.10) M20 (½” NPT) M20 (½” NPT) 3 A1 D1 D1 D1 A A A A1 A1 M20 (½” NPT) 2 x M25 155 (6.10) L 7ME6520: DN 15 ... 40 (½" ... 1½") L L 7ME6520: DN 50 ... 300 (2" ... 12") 7ME6520: DN 350 ... 2000 (14" ... 78") 7ME6580: DN 25 ... 2000 (1" ... 78") 7ME6520 NBR or EPDM liner [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] [mm] [inch] 15 25 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 750 800 900 1000 177 187 202 188 194 200 207 217 232 257 284 310 382 407 438 463 514 564 591 616 663 714 714 765 820 - 7.0 7.4 8.0 7.4 7.6 7.9 8.1 8.5 9.1 10.1 11.2 12.2 15.0 16.0 17.2 18.2 20.2 22.2 23.3 24.3 26.1 28.1 28.1 30.1 32.3 - 331 341 356 342 348 354 361 371 386 411 438 464 536 561 592 617 668 718 745 770 817 868 868 919 974 - 13.0 13.4 14.0 13.5 13.7 14.0 14.2 14.6 15.2 16.2 17.2 18.3 21.1 22.1 23.3 24.3 26.3 28.3 29.3 30.3 32.2 34.2 34.2 36.2 38.3 - 77 96 127 76 89 102 114 140 168 219 273 324 451 502 563 614 715 816 869 927 1032 1136 1136 1238 1348 - 3.0 3.8 5.0 3.0 3.5 4.0 4.5 5.5 6.6 8.6 10.8 12.8 17.8 19.8 22.2 24.2 28.2 32.1 34.2 36.5 40.6 44.7 44.7 48.7 53.1 - 187 187 197 205 212 222 242 255 276 304 332 357 362 387 418 443 494 544 571 606 653 704 704 755 810 925 972 1025 1123 1223 7.4 7.4 7.8 8.1 8.3 8.7 9.5 10.0 10.9 12.0 13.1 14.1 14.3 15.2 16.5 17.4 19.4 21.4 22.5 23.9 25.7 27.7 27.7 29.7 31.9 36.4 38.2 40.4 44.2 48.1 341 351 359 366 376 396 409 430 458 486 511 516 541 572 597 648 698 725 760 807 858 858 904 964 1079 1126 1179 1277 1377 13.4 13.8 14.1 14.4 14.8 15.6 16.1 16.9 18.0 19.1 20.1 20.3 21.3 22.5 23.5 25.5 27.5 28.5 29.9 31.8 33.8 33.8 35.6 38.0 42.5 44.3 46.4 50.3 54.2 104 124 139 154 174 214 239 282 338 393 444 451 502 563 614 715 816 869 927 1032 1136 1136 1238 1348 1574 1672 1774 1974 2174 4.09 4.88 5.47 6.06 6.85 8.43 9.41 11.1 13.31 15.47 17.48 17.76 19.76 22.16 24.17 28.15 32.13 34.21 36.5 40.63 44.72 44.72 48.74 53.07 61.97 65.83 69.84 77.72 85.59 200 200 200 200 200 200 250 250 300 350 450 500 550 600 600 600 600 700 750 800 900 1000 1000 1100 1200 1400 1500 1600 1800 2000 7.9 7.9 7.9 7.9 7.9 7.9 9.8 9.8 11.8 13.8 17.7 19.7 21.7 23.6 23.6 23.6 23.6 27.6 29.5 31.5 35.4 39.4 39.4 43.3 47.2 55.1 59.1 63.0 70.9 78.7 1200 1400 1500 1600 1800 2000 1) D1 A A1 L1) A ½ 1 1½ 2 2½ 3 4 5 6 8 10 12 14 16 18 20 24 28 30 32 36 40 42 44 48 54 60 66 72 78 A1 7ME6580 Ebonite liner Nominal size D1 Tolerances on build in length: DN 15 to DN 200 (½" to 8"): +0/-3 mm (+0/-0.12"), DN 250 to DN 400 (10" to 16"): +0/-5 mm (+0/-0.20"), DN 450 to DN 600 (18" to 24"): +5/-5 mm (+0.20/-0.20"), DN 700 to DN 2000 (28" to 78"): +10/-10 mm (+0.39/-0.39") - not available Siemens FI 01 · 2016 3/103 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 5100 W Weight 7ME6520 NBR or EPDM liner 3 7ME6580 Ebonite liner Nominal size PN 10 Class 150/AWWA AS [mm] [inch] [kg] [lb] PN 16 [kg] [lb] PN 40 [kg] [lb] [kg] [lb] [kg] [lb] PN 16 [kg] [lb] 15 ½ - - - - 4 9 4 9 4 9 5 11 25 1 - - - - 6 12 5 11 4 9 5 11 40 1½ - - - - 8 18 7 15 7 15 8 17 50 2 - - 9 20 - - 8 20 9 20 9 20 65 2½ - - 10.7 24 - - 11 24 10.7 24 11 24 80 3 - - 11.6 26 - - 13 28 11.6 26 12 26 100 4 - - 15.2 33 - - 19 41 15.2 33 16 35 125 5 - - 20.4 45 - - 24 52 - - 19 42 150 6 - - 26 57 - - 29 64 26 57 27 60 200 8 48 106 48 106 - - 56 124 48 106 40 88 250 10 64 141 69 152 - - 79 174 69 152 60 132 300 12 76 167 86 189 - - 110 243 86 189 80 176 350 14 104 229 125 274 - - 139 307 115 254 110 242 400 16 119 263 143 314 - - 159 351 125 277 125 275 450 18 136 299 173 381 - - 182 400 141 311 175 385 500 20 163 359 223 491 - - 225 495 189 418 200 440 600 24 236 519 338 744 - - 320 704 301 664 287 633 700 28 270 595 314 692 - - 273 602 320 704 330 728 750 30 - - - - - - 329 725 - - 360 794 800 32 346 763 396 873 - - 365 804 428 944 450 992 900 36 432 951 474 1043 - - 495 1089 619 1362 530 1168 1000 40 513 1130 600 1321 - - 583 1282 636 1399 660 1455 42 - - - - - - 687 1512 - - - - 44 - - - - - - 763 1680 - - 1140 2513 1200 48 643 1415 885 1948 - - 861 1896 813 1789 1180 2601 1400 54 1592 3510 - - - - - - - - 1600 3528 1500 60 - - - - - - - - - - 2460 5423 1600 66 2110 4652 - - - - - - - - 2525 5566 1800 72 2560 5644 - - - - - - - - 2930 6460 2000 78 3640 8025 - - - - - - - - 3665 8080 - not available With transmitter MAG 5000 and MAG 6000 compact, weight is increased by approximately 0.8 kg (1.8 lb), with MAG 6000 I, weight is increased by 5.5 kg (12.1 lb). 3/104 Siemens FI 01 · 2016