MIC5332 Evaluation Board

MIC5332 Evaluation Board
Micro-Power High Performance
Dual 300mA ULDO™
voltage is monitored at the VIN terminal, as the
ammeter and/or power lead resistance can reduce
the voltage supplied to the input.
General Description
The MIC5332 is a tiny dual low quiescent current LDO.
The MIC5332 provides two high performance 300mA
LDOs, and a POR generator into a 2mm x 2mm Thin MLF®
package.
The MIC5332 dual Ultra Low Dropout (ULDO™) linear
regulator is easy to use. A minimum output capacitance of
1µF for each of the outputs is required.
An input capacitor is required when the power supply is
more than 4-inches away from the device. The evaluation
board includes an input capacitor of 1µF to allow for long
inductive test leads.
2. Enable/Disable the MIC5332. The evaluation
board is provided with 10k pull up resistors on
both of the enable pins (EN1 and EN2) to VIN. To
disable an output, simply jumper the EN terminal
(J5 for LDO1, J4 for LDO2) to the GND terminal
(J2). The enable pins must be either pulled high or
low. Removing the pull up resistors and leaving
the pins floating will cause the regulators to
operate in an indeterminate state.
3. Connect the loads to the VOUT terminals (J6 for
LDO1, J8 for LDO2) and ground terminal (J7).
The load can be either a passive (resistor) or
active (electronic load). Be sure to monitor the
output voltage at the VOUT (J6 and J8) terminals.
Requirements
The MIC5332 evaluation board requires an input power
source that is able to deliver greater than 600mA with an
input voltage range of 2.3V to 5.5V. The output load can
be either an active or passive load.
Precautions
The evaluation board does not have reverse polarity
protection. Applying a negative voltage to the VIN terminal
may damage the device.
The MIC5332 evaluation board is tailored for a Li-Ion
range input supply voltage. It should not exceed 5.5V on
the input.
Getting Started
1. Connect an external supply to VIN. Apply the
desired input voltage to the VIN (J1) and ground
terminal (J2) of the evaluation board, paying
careful attention to polarity and supply voltage
(2.3V ≤ VIN ≤ 5.5V). An ammeter may be placed
between the input supply and the VIN terminal to
the evaluation board. Ensure that the supply
4. Monitoring Power on Reset. Connect an
oscilloscope to the POR2 terminal (J3) and ground
terminal (J7). The evaluation board has a 0.1µF
capacitor connected from the CSET2 pin-to-GND.
This corresponds to a delay of 100ms on the
POR2 output. The POR2 delay time can be
modified by changing the value of C4 with a rate of
1s/µF, or removing C4 for zero delay.
Ordering Information
Part Number
Description
MIC5332-XXYMT EV
Evaluation board with the
300mA Dual ULDO™ device
ULDO is a trademark of Micrel, Inc.
MLF and MicroLeadFrame are registered trademarks of Amkor Technology, Inc.
Micrel Inc. • 2180 Fortune Drive • San Jose, CA 95131 • USA • tel +1 (408) 944-0800 • fax + 1 (408) 474-1000 • http://www.micrel.com
January 2008
M9999-012408-A
Micrel, Inc.
MIC5332 Evaluation Board
Evaluation Board Schematic
U1
MIC5332-xxYMT
VIN
J1
VIN
1
R3
10k
J3
POR
J4
EN2
R2
10k
VOUT1
POR2
VOUT2
8
J6
VOUT1
7
J8
VOUT2
R1
10k
3
4
J5
EN1
VIN
5
EN2
EN1
CSET2
GND
C1
1µF
6
C4
0.1µF
2
C2
1µF
C3
1µF
J2
GND
J7
GND
Bill of Materials
Item
Part Number
Manufacturer
C1, C2, C3
C1608X5R0J105K
TDK(1)
C4
R1, R2, R3
U1
VJ0603Y104KXXAT
CRCW06031002FKEYE3
MIC5332-XXYMT
Qty
3
(2)
Capacitor, 0.1µF Ceramic, 10V, X7R, Size 0603
1
(2)
Resistor, 10kΩ, 1%, 1/16W, Size 0603
Vishay
Vishay
Micrel
Description
Capacitor, 1µF Ceramic, 6.3V, X5R, Size 0603
(3)
3
®
UCAP LDO, Dual 300mA, Size 2mm x 2mm Thin MLF
1
Notes:
1.
TDK: www.tdk.com
2.
Vishay: www.vishay.com
3.
Micrel, Inc.: www.micrel.com
January 2008
2
M9999-012408-A
Micrel, Inc.
MIC5332 Evaluation Board
PCB Layout Recommendations
1350 (mil)
1400 (mil)
Top Layer
1350 (mil)
1400 (mil)
Bottom Layer
January 2008
3
M9999-012408-A
Micrel, Inc.
MIC5332 Evaluation Board
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA
TEL +1 (408) 944-0800 FAX +1 (408) 474-1000 WEB http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its
use. Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product
can reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant
into the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A
Purchaser’s use or sale of Micrel Products for use in life support appliances, devices or systems is a Purchaser’s own risk and Purchaser agrees to fully
indemnify Micrel for any damages resulting from such use or sale.
© 2008 Micrel, Incorporated.
January 2008
4
M9999-012408-A