MLX90808 datasheet old 687 DownloadLink 5381

MLX90808
Absolute Integrated Pressure Sensor
Features and Benefits
Absolute Integrated Pressure sensor
Less than 1% error range overall
Programmable through the connector (3 pins)
Trimmable offset and sensitivity
Ratiometric output
Rail-to-Rail output
Output proportional to the applied pressure
Diagnostics of broken supply wires and broken sensor
Output protected against short-circuits at both battery terminals
On-chip Signal Conditioning (single die solution)
Different pressure ranges available
Application Examples
Automotive applications (MAP, T-MAP, HVAC, …)
Industrial applications
Barometric Air Pressure
Ordering Information
Part No.
MLX90808
Temperature Suffix
L (-40°C to 150°C)
Package Code
UF (die on foil)
1 Functional Diagram
Option
-2
Description
3 to 7 Bar Pressure Span
2 General Description
The MLX90808 is an integrated absolute
pressure sensor realised in CMOS
technology. It consists of an analog signal
chain that interacts with the digital core and
on-chip temperature sensor in order to
provide uniform overall sensing
characteristics after calibration and to cancel
the temperature related parameter drifts.
The output is proportional to the applied
pressure with an adjustable slope and offset.
The chip is ratiometric and goes rail-to-rail
with a 1mA source and sink capability.
3901090808
Rev 001
Page 1 of 8
Data Sheet
Feb 08
MLX90808
Absolute Integrated Pressure Sensor
Table of Contents
1 Functional Diagram........................................................................................................... 1
2 General Description .......................................................................................................... 1
3 Absolute Maximum Ratings .............................................................................................. 3
4 General Electrical Specifications....................................................................................... 3
5 Diagnostic features ........................................................................................................... 4
6 Detailed General Description ............................................................................................ 4
7 Unique Features ............................................................................................................... 5
8 Application Information ..................................................................................................... 5
9 Programming and Calibration ........................................................................................... 6
9.1 Programming of the Temporary Memory of 90808 ..................................................... 6
9.2 Zapping of the 90808 .................................................................................................. 7
10 Disclaimer ....................................................................................................................... 8
3901090808
Rev 001
Page 2 of 8
Data Sheet
Feb 08
MLX90808
Absolute Integrated Pressure Sensor
3 Absolute Maximum Ratings
Parameter
Symb
ol
Supply Voltage (overvoltage)
VDD
Supply Voltage (operating)
VDD
Supply Current, IDD with VDD = 16 V
IDD
Output Voltage, Vout
Vout
Supply current with output shorted to 0V .. 16V IDD
Supply Current limit, reverse polarity
IDD
Programming Temperature Range (ZAP cells) TP
Operating Temperature Range
TA
Storage Temperature Range
TS
ESD Sensitivity (AEC Q100 002)
Table 1: Absolute maximum ratings
Min Value
Max Value
Units
-14
4.5
16
5.5
25
16
100
160
100
140
150
2
V
V
mA
V
mA
mA
°C
°C
°C
kV
-0.5
-20
-40
- 50
-2
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximumrated conditions for extended periods may affect device reliability.
4 General Electrical Specifications
o
o
DC Operating Parameters TA = -40 C to 140 C, VDD = 5V (unless otherwise specified)
Parameter
Symbol
Supply Voltage
Vdd
Supply Current
Idd
Output Current Capability
Iout
output @ low pressure
Vout
output @ full scale pressure Vout
Low Clamping level
Vout
High Clamping level
Vout
Linearity error
Vout
Ratiometricity error
Vout
Programming Supply
Vcc prog
Zapping Supply
Vzap
Zapping Temperature
Tzap
Lifetime
Power-up time
Power-up time
Response time 0% / 63%
Trp
Response time 10% / 90% Trp 10 – 90
Stabilization time
Ts
Pressure accuracy
Table 2: Electrical specifications
3901090808
Rev 001
Test Conditions
Operating
Vdd = 5 V ± 10% , excluding output current
Vdd = 5 V
Vdd = 5 V
Vdd = 5 V
o
o
T = 0 C … 85 C
o
o
T < 0 C or T > 85 C
Page 3 of 8
Min Typ
4.5
5
4
7
1
0.46 0.5
4.46 4.5
6.5
91
-0.5
-0.3
10
15.5
- 20
15
3.5
5
1
1.5
3
Max Units
5.5
V
10
mA
mA
0.54
V
4.54
V
8.5 % Vod
93.5 % Vod
0.5 % Vod
0.3 % Vod
10.5
V
16
V
o
C
100
Year
ms
ms
ms
ms
ms
1
% FS
Data Sheet
Feb 08
MLX90808
Absolute Integrated Pressure Sensor
5 Diagnostic features
DC Operating Parameters TA = -40oC to 140oC, VDD = 5 V (unless otherwise specified)
Parameter
Symbol
Output when sensor is broken
Output when Vdd is broken
Output when Vdd is broken
Output when Vss is broken
Output when Vss is broken
Table 3: Diagnostic features
Test Conditions
Sensor broken
Pull up > 4k7
Pull down
Pull down > 10kΩ
Pull up
Min
Typ
Max
2
4
0
96
100
Units
% Vdd
% Vdd
% Vdd
% Vdd
% Vdd
6 Detailed General Description
This chip integrates a pressure sensor and the associated signal conditioning on the same die. The supply
voltage VDD directly supplies the pressure sensor.
The pressure sensing element consists of a square diaphragm realized in the silicon chip by backside
etching. Due to its small thickness this diaphragm reacts to a pressure difference at both of its side by
cambering. The internal strain increases, in particular at the border of the diaphragm. Here, the piezoresistive elements have been implanted into the silicon diaphragm, which act as transducer.
The piezo-resistive elements react to pressure induced changes of strain by changes in their resistance. Four
resistors are placed at all four borders of the square diaphragm. They are arranged in a Wheatstone-bridge.
A chopped instrumentation stage amplifies the differential output signal of the sensor. The gain of this
amplifier can be adjusted with 3 bits. After the input stage, there is a 3 bit programmable coarse offset which
is followed by a differential to single-ended conversion. The reference voltage for this stage is generated by a
10 bit DAC and varies linearly with temperature in order to perform the offset and offset drift compensation. A
digital hardware multiplier calculates this compensation. The temperature signal, serving as input for this
multiplier, is generated from the ADC of the output signal of the internal temperature sensor.
The chopped signal is demodulated with a switched capacitor stage. The buffered output serves as reference
for a 10 bit DAC to perform the span and span drift compensation. The DAC is controlled by the digital part.
Finally the signal is given out by a class AB rail-to-rail amplifier capable of sourcing and sinking large
currents.
A 3-point temperature and 2-point pressure calibration is required (room temperature, a low temperature and
a high temperature), to achieve an error less than ±1% over the complete pressure and temperature range
(the output error is referred to the output span).
PTC (Programming Through Connector) protocol is used to perform calibration.
The programming of the sensor chip is carried out via the analog connections (i.e. supply, ground, signal out).
No additional pins are necessary for calibration.
The output circuit is protected against short circuit to GND, Vbat (16V) and Vdd.
3901090808
Rev 001
Page 4 of 8
Data Sheet
Feb 08
MLX90808
Absolute Integrated Pressure Sensor
7 Unique Features
Diagnostic Limits
Diagnostic of broken sensor: The output will be forced to ground (or a very low level) when the sensor
membrane breaks.
Diagnostic of broken wires: The output will be forced to ground (or a very low level) when the supply wire
breaks, even when a pull-up is still connected to the output pin.
The output will be forced to the supply voltage (or a very high level) when the ground wire breaks, even when
a pull-down is still connected to the output pin.
Output Protection
The output is protected against short-circuits at either battery terminals. The output can handle voltages
between -0.5V and 16V (independent of supply voltage).
Memlock Function
The memory consists of ZAP cells. When all calibration parameters are programmed, the chip can be locked.
This to avoid unwanted that data be written into the memory cells.
Once the chip is locked in a normal application, we can not read the zap contents and it is not possible to
unlock afterwards, unless the MOW pin is used. This can be done by apply a supply between 2.5V and 3.5V
on the MOW pin, then we can read back the content of the memory cells and zap another cell if necessary.
Clamping Levels
The user can enable the clamping of the output to ensure that the output can not enter the fault band in
normal application.
8 Application Information
47nF
47nF
Very few off-chip components are needed (only 2 decoupling capacitors, not higher than 100 nF).
Only 3 pins are used (Vdd, Vss, Out), see pad layout drawing in paragraph 9.
Calibration and Programming is made through the OUT pin.
3901090808
Rev 001
Page 5 of 8
Data Sheet
Feb 08
MLX90808
Absolute Integrated Pressure Sensor
9 Programming and Calibration
9.1 Programming of the Temporary Memory of 90808
The temporary memory consists of a shift register of flip flops. It is used to search for the correct calibration
settings. Mode 1 (TC[5:0]=01h) is used for this purpose. Afterwards these settings can be put in the
permanent memory. The programming is done through the connector: you only need the application pins
(supply, ground and output). You can enable the programming by forcing the supply high enough (VCC_T).
You can input the data through the OUT pin. The data is Pulse Width modulated. At the end of the
programming, we keep OUT high until VCC has reached his normal level (VCC_N). Thereafter we disconnect
OUT. It is not necessary to do a power-down before the next settings are programmed.
Timings
3901090808
Rev 001
Page 6 of 8
Data Sheet
Feb 08
MLX90808
Absolute Integrated Pressure Sensor
9.2 Zapping of the 90808
The permanent memory of the 90808 is built with zap cells.
The data output of an unprogrammed zap cell is 0. The data output is 1 when the cell is zapped.
It is not possible to reprogram a zap cell to 0. Only 1 bit can be zapped at a time.
You should use the normal mode (TC[5:0]=00h) and program 1 bit to '1' in the temporary memory.
Afterwards you need to increase the supply voltage (VCC_Z) to be able to zap the bit. The zapping starts
when OUT goes high (OUT_Z). There will flow a high current of approximately 200mA during the zapping.
The memlock-bit should be zapped as last bit, because it disables the programming.
The zap cells can also be read out by using mode 5 (TC[5:0]=05h).
One bit should be set to 1 in the temporary memory.
The supply current should be measured at the normal supply voltage.
A low current (ICC_R0) indicates that the zap cell is not programmed.
A high current (ICC_R1) indicates that the zap cell is programmed.
3901090808
Rev 001
Page 7 of 8
Data Sheet
Feb 08
MLX90808
Absolute Integrated Pressure Sensor
10 Disclaimer
Devices sold by Melexis are covered by the warranty and patent indemnification provisions appearing in its
Term of Sale. Melexis makes no warranty, express, statutory, implied, or by description regarding the
information set forth herein or regarding the freedom of the described devices from patent infringement.
Melexis reserves the right to change specifications and prices at any time and without notice. Therefore, prior
to designing this product into a system, it is necessary to check with Melexis for current information. This
product is intended for use in normal commercial applications. Applications requiring extended temperature
range, unusual environmental requirements, or high reliability applications, such as military, medical lifesupport or life-sustaining equipment are specifically not recommended without additional processing by
Melexis for each application.
The information furnished by Melexis is believed to be correct and accurate. However, Melexis shall not be
liable to recipient or any third party for any damages, including but not limited to personal injury, property
damage, loss of profits, loss of use, interrupt of business or indirect, special incidental or consequential
damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical
data herein. No obligation or liability to recipient or any third party shall arise or flow out of Melexis’ rendering
of technical or other services.
© 2005 Melexis NV. All rights reserved.
For the latest version of this document, go to our website at
www.melexis.com
Or for additional information contact Melexis Direct:
Europe, Africa, Asia:
Phone: +32 1367 0495
E-mail: [email protected]
America:
Phone: +1 603 223 2362
E-mail: [email protected]
ISO/TS 16949 and ISO14001 Certified
3901090808
Rev 001
Page 8 of 8
Data Sheet
Feb 08