Structure of the 16 digit order number for standard IEC motors 1LE, 1MB and 1PC Main series 1st 2nd 3rd Order no position 1 L E Standard type 1 M B Explosion Proof 1 P C Definite Purpose Versions 5th 6th 7th Order no. position 0 General purpose motor, Aluminum 5 Severe duty motor, cast-iron Basic Line 6 Severe duty motor, cast-iron Performance Line Number of poles 10th Order No. position 1 IEC Motors 2 NEMA Motors 0 1 0 2 0 3 1 1 2 2 1 2 1 3 High efficiency IE2 Standard efficiency IE1 Premium efficiency IE3 Pole-changing 1 winding Pole changing 2 windings NEMA “Eagle Line” Energy efficient motors NEMA “Eagle Line” Premium efficient motors Voltage code 12th 13th Order no. position 50 Hz 0 2 400 Y 2 1 220 V ∆ / 380 V Y 2 2 2 3 3 4 9 2 3 7 3 4 0 0 230 V ∆ / 400 V Y 240 V ∆ / 415 V Y 500 V Y 380 V ∆ / 660 V Y 400 V ∆ / 690 V Y 500 V ∆ Non-standard winding Mechanical design 16th Order no. position 4 Terminal box on top 5 Terminal box on RHS 6 Terminal box on LHS 7 Terminal box below 60 Hz 460 V Y 440 V Y 460 V Y 440 V ∆ 460 V ∆ Order no. 1st 2nd 3rd 4th 5th 6th 7th – 8th 9th 10th 11th 12th – 13th 14th 15th 16th Order code 1 L E 1 0 2 1 – 1 A A 4 3 – A A A 4 Frame Size Number of poles Construction Length 8th & 9th position 10th Order no. position 11th Order no. position 0 1 Construction length S Rated output kW kW FS 0B 63 0C 71 0D 80 0E 90 1A 100 1B 112 1C 132 1D 160 1E 180 2A 200 2B 225 2C 250 2D 280 3A 315 2-pole 4-pole 6-pole 2-pole 4-pole 6-pole 8-pole 2-pole 4-pole 6-pole 8-pole 2-pole 4-pole 6-pole 8-pole 2-pole 4-pole 6-pole A B C A B C D A B C D A B C D A B C 8-pole 2-pole 4-pole 6-pole 8-pole 2-pole 4-pole 6-pole 8-pole 2-pole 4-pole 6-pole 8-pole 2-pole 4-pole 6-pole 8-pole 2-pole 4-pole 6-pole 8-pole 2-pole 4-pole 6-pole 2-pole 4-pole 6-pole 2-pole 4-pole 6-pole 2-pole 4-pole 6-pole D A B C D A B C D A B C D A B C D A B C D A B C A B C A B C A B C 1.5 1.1 0.75 0.37 Rated output in horsepower 2 3 4 5 Construction length S Construction length S Rated output Rated output kW kW kW kW 0.18 0.25 0.12 0.18 0.09 0.12 0.37 0.55 0.25 0.37 0.18 0.25 0.09 0.12 0.75 1.1 0.55 0.75 0.37 0.55 0.18 0.25 2.2 1.5 1.1 0.55 3 2.2 3 1.5 0.75 1.1 4 4 2.2 1.5 5.5 5.5 3 2.2 7.5 7.5 4 3 11 11 7.5 4 22 18.5 5.5 15 5.5 18.5 15 11 7.5 22 15 11 30 18.5 37 75 75 45 110 110 75 45 45 30 55 55 37 90 90 55 132 132 90 160 160 110 6 High-performance Rated output kW 0.37 0.25 0.18 0.75 0.55 37 0.18 1.5 1.1 0.75 0.37 3 2.2 1.5 0.75 4 4 2.2 Number of poles 10th Order No. position A 2 B 4 C 6 D 8 E 10 F 12 G 14 H 16 J 4/2 Constant torque K 6/4 Constant torque L 8/4 Constant torque M 8/6/4 Constant torque N 8/6 Constant torque P 4/2 Square-law load torque Q 6/4 Square-law load torque R 8/4 Square-law load torque S 8/6/4 Square-law load torque T 8/6 Square-law load torque Type of construction 14th Order no. position A IM B3, IM B6, IM B7, IM B8, IM V5, IM V6, stamped IM B3 C IM V5 D IM V6 F IM B5, IM V1, IM V3, stamped IM B5 fl ange G IM V1 flange H IM V3 flange J IM B35 flange K IM B14, IM V19, IM V18 stamped IM B14; standard flange L IM V19 standard flange M IM V18 standard flange N IM B34 standard flange T IM B6 U IM B7 V IM B8 Z ß P01 Next larger fl ange P02 Next smaller fl ange H00 Protective cover Order Code -Z ... Motor protection 15th Order no. position A Without thermal protection B 3 PTC Thermistors (tripping) C 6 PTC Thermistors (warning + tripping) F Temperature sensor KTY84-130 1.5 5.5 5.5 3 2.2 11 11 7.5 4 22 18.5 15 11 37 30 22 15 200 200 132 usa.siemens.com/nemamotors Subject to change without prior notice. The representation does not replace catalog information, not all of the represented order numbers are or will be realized. Order No: XXXX-XXXX-2013 All rights reserved. Printed in USA. ©2013 Siemens Industry, Inc. SIMOTICS IEC Low Voltage motors MLFB