Guide - Optima Series ICP-OES Sample Introduction Components

Optima series
ICP-OES
REFERENCE
GUIDE
Sample
Introduction
Components
Nebulizers
Suitable for Optima 2X00, 4X00, 5X00, 7X00 DV and V
Description
Part No.
SeaSpray™ U-Series™ Nebulizer, 2 mL/min uptake
N0775345
For best performance or for samples with high salt content
Conikal™ U-Series™ Nebulizer, 2 mL/min uptake
N0777487
For routine analysis
MicroMist™ U-Series™ Nebulizer, 0.6 mL/min uptake
N0775346
MicroMist™ U-Series™ Nebulizer, 0.2 mL/min uptake
N0775347
MicroMist U-Series Nebulizer, 0.1 mL/min uptake
N0775348
MicroMist U-Series Nebulizer, 0.05 mL/min uptake
N0775349
™
™
™
™
For organics or for samples with limited volume
Slurry™ U-Series™ Nebulizer, 4 mL/min uptake
N0777488
For slurries or suspensions – ideal for wear metals in oil
PolyCon™ Nebulizer, 2 mL/min uptake
N0777490
For samples containing HF
VeeSpray™ Ceramic Nebulizer
Most versatile nebulizer – handles samples containing particulates and high salt content and HF
www.perkinelmer.com
N0777489
Spray Chambers
Suitable for Optima 2X00, 4X00, 5X00, 7X00 DV
Description
Part No.
Tracey Cyclonic Spray Chamber
N0776052
™
Tracey Cyclonic Spray Chamber with Helix
™
N0775351
™
For best sensitivity
Twister™ Cyclonic Spray Chamber (7 mm baffle)
N0776053
Twister™ Cyclonic Spray Chamber with Helix™ (7 mm baffle)
N0775352
For best precision
Twister™ Cyclonic Spray Chamber (4 mm baffle)
N0776090
Twister™ Cyclonic Spray Chamber with Helix™ (4 mm baffle)
N0775355
For organics
Jacketed Twister™ Cyclonic Spray Chamber with Helix™
N0774101
For organics – chiller required
Cinnabar™ Cyclonic Spray Chamber with Helix™
N0777494
Twinnabar™ Baffled Cyclonic Spray Chamber with Helix™
N0777495
For samples with limited volume
Tracey™ TFE Cyclonic Spray Chamber with Helix™
N0777496
For samples containing HF
Spray Chambers
Suitable for Optima 4X00, 5X00, 7X00 V
Description
Part No.
Twister Baffled Cyclonic Spray Chamber
N0771501
™
Twister Baffled Cyclonic Spray Chamber with Helix
™
™
N0775356
For aqueous or organics
Tracey™ TFE Cyclonic Spray Chamber with Helix™
N0777497
TC-44 Cyclonic Spray Chamber
N0771550
For samples containing HF
Torches and Torch Parts
Suitable for Optima 2X00, 4X00, 5X00, 7X00 DV
Description
Part No.
D-Torch for Optima 2/4/5/7000 DV
™
™
N0777508
Demountable torch reduces torch replacement costs
Base and Inner Tube for D-Torch™ Optima 2/4/5/7000 DV
N0777509
Quartz Outer Tube for D-Torch Optima 2/4/5/7000 DV
N0777510
Safety Gloves – Medium
N0777421
™
2
Torches and Torch Parts
Suitable for Optima 4X00, 5X00, 7X00 V
Description
Part No.
D-Torch for Optima 4/5/7000 V
N0777051
™
Demountable torch reduces torch replacement costs
Base and Inner Tube for Optima 4/5/7000 V D-Torch™
N0777054
Quartz Outer Tube for Optima 4/5/7000 V D-Torch™
N0777053
Ceramic Outer Tube for Optima 4/5/7000 V D-Torch™
N0777052
For extended life – ideal for oil analysis
Retaining Ring for D-Torch™
N0777055
Safety Gloves – Medium
N0777421
Torch Adaptor with Auxiliary Port
N0774070
Internal Standard Kit and Spares
Suitable for all models
Description
Part No.
Internal Standard Kit with orange/blue flared end tubing
N0774068
HF-resistant Internal Standard Kit with orange/blue flared end tubing
N0774067
EzyFit™ glass mixing T-piece
N0777461
HF-resistant mixing T-piece
N0777466
EzyFit sample tube, twin (pack of 6)
N0777462
UniFit -EzyFit sample tube (pack of 6)
N0777061
EzyFit™ sample tube, 0.5 mm ID (pack of 10)
N0777463
EzyFit™ sample tube, 0.25 mm ID (pack of 10)
N0777464
Internal standard probe
N0777465
Flared end orange/blue 2 tag PVC peristaltic pump tubing 0.25 mm ID (pack of 6)
N0773112
™
™
™
Connectors and Misc. Parts
Description
Part No.
Hose clip (pack of 10)
N0773197
UniFit Connector with 0.75mm ID x 1.3 mm OD x 700 mm long sample tube (pack of 10)
N0777512
UniFit™ Connector with 0.50 mm ID x 1.3 mm OD x 700 mm long sample tube (pack of 10)
N0777513
UniFit™ Connector with 0.25 mm ID x 1.3 mm OD x 700 mm long sample tube (pack of 10)
N0777514
EzyFit™ Connector with 0.75 mm ID x 1.3 mm OD x 700 mm long sample tube (pack of 10)
N0777435
EzyFit™ Connector with 0.50 mm ID x 1.3 mm OD x 700 mm long sample tube (pack of 10)
N0777436
EzyFit™ Connector with 0.25 mm ID x 1.3 mm OD x 700 mm long sample tube (pack of 10)
N0777437
UniFit™ Drain Connector with 1.3 mm OD X 0.75 mm ID x 700 mm long drain tube (pack of 3)
N0774077
UniFit™ Drain Connector with 1/16 inch OD X 0.75 mm ID x 700 mm long drain tube (pack of 3)
N0774080
EzyLok connector for 1/4 inch tubing (pack of 4)
N0774100
EzyLok Kit
N0777413
Nebulizer Adaptor for Cyclonic Spray Chamber 16/6
N0776006
O’ring Set for Nebulizer Adaptor 16/6
N0776007
Helix Locking Screw
N0777438
Helix Seal (pack of 4)
N0777439
™
™
™
™
™
Accessories
Description
Part No.
Argon Humidifier
N0775331
For samples with high salt content
Eluo™ Nebulizer Cleaner
N0775358
To unblock nebulizers
IsoMist™ Kit for Optima 4300/5300/7300 V
N0777362
IsoMist Kit for Optima 2/4/5/7000 DV
N0777363
™
Programmable temperature spray chamber
Improves stability, simplifies analysis
of volatile organics
PerkinElmer, Inc.
940 Winter Street
Waltham, MA 02451 USA
P: (800) 762-4000 or
(+1) 203-925-4602
www.perkinelmer.com
For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs
Copyright ©2010, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners.
009006_01