NexION ICP-MS Consumables and Supplies Reference Guide

Consumables and Supplies
NexION® 300/350 ICP-MS
Sampler and Skimmer Cones
Precision-designed and manufactured, large-orifice sampler and skimmer cones provide superior long-term stability and resist clogging, allowing
analysis under both high and low sample-uptake conditions. Nickel is a very rugged, long-lasting material for the majority of sample types, while
platinum is the material of choice for more corrosive samples. They have been designed to maximize signal stability and to minimize clogging
during extended runs of samples containing high dissolved solids.
Nickel Sampler and Skimmer Cones
Type
Sampler
Skimmer
Part No.
W1033612
W1026356
Platinum Sampler and Skimmer Cones
Type
Sampler
Skimmer
Part. No.
W1033614
W1026907
Hyper Skimmer Cone
Type
Hyper Skimmer
Part No.
W1033995
Replacement Parts
Description
Sampler Gasket
Hyper Skimmer O-Ring
Hyper Skimmer Screw
Cone Removal Tool
Torch Alignment Tool
Part No.
W1040148
09902123
WE027484
W1034694
WE015554
Torches
Part No.
Demountable Quartz Torch
N8122006
The EasyGlide™ torch mount and alignment system for the NexION ICP-MS is a demountable design that incorporates a
quartz torch with a fully replaceable sample injector made of fused alumina, quartz or sapphire. High Efficiency Demountable Quartz Torch
Part No.
N8145318
Operates at 25% reduced argon gas flows compared to the standard Demountable Quartz Torch (N8122006).
Nebulizers
MEINHARD® Nebulizers
The MEINHARD® Concentric Nebulizer reflects exacting standards in design and manufacturing. Its advantages
include simplicity of design and operation, reproducible and self-aligning aerosol, and close fabrication control. They
provide excellent sensitivity and precision for aqueous solutions and samples with few dissolved solids (less than 1%).
MEINHARD® Nebulizers are self-aspirating.
Model Type A Type C Material Quartz
Glass AR Flow Rate 1.0 L/min
1.0 L/min
Uptake Rate 0.5 mL/min, 50 psig
0.5 mL/min, 50 psig
Part No.
N8145011
N81450 12
Spray Chambers
The Cyclonic Spray Chamber relies on momentum to efficiently and quickly remove the larger droplets from the sample
mist decreasing any opportunity for occlusion or agglomeration of the smaller droplets. The result is higher efficiency,
better precision and faster washouts than other spray chamber designs. For use with ball joint injectors.
• Decreased sample introduction system installation and optimization time due to the preset nature of the spray
chamber/nebulizer combination
• More samples per hour due to minimal dead volume and efficient draining
Type Quartz Cyclonic Spray Chamber
Glass Cyclonic Spray Chamber
Replacement Spray Chamber Nut PFA Spray Chamber with PFA End Cap
(Requires PFA body injector N8122411 or N8122412 or N8122413)
PFA 6 mm Secure Replacement Nut for Quartz Cyclonic Spray Chambers
Part No.
N8145013
N8145014
N8141420
N8142000
N8141420
Adapters, Fittings and O-Rings
Adapters and Fittings
Description
1 Nebulizer Fitting
1
2 Spray Chamber Drain Fitting
3 Male barb CTFE Fitting
4 Female barb CTFE Fitting
2
4
2
3
Part No. N8145016
N8145015
N8145017
N8145018
Adapters, Fittings and O-Rings, continued
O-Rings
Description
Qty
Part No.
Injector Adapter Kit (Includes items listed below)
Adapter
1
O-Ring 3/8 inch i.d. x 1/16 inch
1
O-Ring 1/4 inch i.d. x 1/16 inch
1
Injector Spacer
1
Injector Nut
1
N8140360
W1012406
W1008572
W1008573
W1012409
W1012408
Injector Adapter Kit 2 (Includes items listed below) Injector O-Ring 0.239 i.d. x 0.070 WD 1
O-Ring 0.551 i.d. x 0.070 WD 1
O-Ring 3/8 inch i.d. x 1/16 inch
1
Adapter 1
Injector Nut 1
Injector Spacer 1
O-Ring 5/8 inch i.d. x 1/8 inch WD 1
N8140527
09210011
N8122010
W1008572
W1012406
W1012408
W1012409
W1013545
O-Ring Kit for Injector Support (Includes items listed below)
Injector O-Ring 0.239 i.d. x 0.070 WD
2
Torch O-Ring 0.364 i.d. x 0.070 WD
2
O-Ring 0.551 i.d. x 0.070 WD
1
O-Ring 5/8 inch i.d. x 1/8 inch WD
1
N8120100
09210011
09210012
N8122010
W1013545
Injectors
Alumina Injectors for use with Ryton® sample introduction system
Alumina injectors provide economical HF resistance. They are vacuum baked to reduce contamination. For use only with
HF resistant (Ryton®) sample introduction system.
• 2.0 mm i.d. for aqueous solutions and less volatile organic solvents
• 1.5 mm i.d. for reduced sample loading
• 0.85 mm i.d. for use with volatile organic solutions
Dimension
2.0 mm i.d.
1.5 mm i.d. 0.85 mm i.d. Part No.
N8126041
N8126040
N8126039
Sapphire Injectors for use with Ryton® sample introduction system
Dimension
2.0 mm i.d.
Part No. N0695495
Quartz Injectors for use with Ryton® sample introduction system
Dimension
1.2 mm i.d.
1.6 mm i.d.
2.0 mm i.d.
Part No. N0681631
00473292
N8125029
Quartz Ball Joint Injectors
Dimension
0.85 mm i.d.
1.5 mm i.d.
2.0 mm i.d. (standard with NexION instrument)
Part No. WE027030
WE027005
WE023948
Support Adapters
Description
Cassette Torch Injector Support Adapter for non-ball joint injectors
Cassette Torch Injector Support Adapter for ball joint injectors
Part No. W1013266
W1012406
3
Sample Introduction Kits
PC3 / PC3-LT Peltier Coolers with Oxygen Port
The PC3 has two preset temperatures +2 ˚C / -5 ˚C and is ideal when running aqueous or aqueous/organic mixtures.
The PC3-LT operates at -20 ˚C when running 100% volatile organic solvents to reduce the solvent load on the plasma.
Includes Quartz spray chamber with additional gas port.
Description
PC3 Organic Sample Introduction Kit PC3-LT Organic Sample Introduction Kit Temperature
+2 ˚C / -5 ˚C
+2 ˚C / -20 ˚C
Spray Chamber
Quartz
Quartz
Part No. N8142003
N8145099
Other Sample Introduction Kits
Description
PFA-Platinum HF-Resistant Sample Introduction Kit
PFA-Sapphire HF-Resistant Sample Introduction Kit
HF Sample Introduction Kit (Ryton®)
Part No. N8142001
N8142002
N8140507
Detectors
SimulScan Dual-Stage Detector
The dual-stage detector is an integral part of the NexION ICP-MS SimulScan™ system. This electron multiplier measures both
high- and low-level analytes simultaneously. This conserves valuable or limited samples, eliminates the need to perform timeconsuming sample dilutions and allows you to quickly characterize unknown samples.
Description
NexION 300/350 ICP-MS Detector
Part No. N8145000
Tubing
Peristaltic Pump Tubing
Description i.d. (mm)
Santoprene®1.30
Flared PVC 0.19
Flared PVC 0.25
Flared PVC 0.38
Stop Colors Gray/Gray
Orange/Red
Orange/Blue
Green/Orange
Part No. N0777444
N0773111
N0773112
N0777042
Additional Tubing
Description
Sample Uptake Tubing (cm)
Drain Tubing (feet)
Torch Box Drain Assembly
Part No. WE024375
02506495
N8140506
Internal Standards Kits
4
Description
HF-Resistant Internal Standard Kit (Includes items listed below)
HF Mixing T-piece
Internal Standard Sample Probe
EzyFit Sample Tube 0.5 mm i.d.
EzyFit with 1/16 inch o.d. x 0.50 mm i.d. x 700 mm long sample tube
EzyFit with 1/16 inch o.d. x 0.25 mm i.d. x 700 mm long sample tube
UniFit-EzyFit Sample Tube – Qty. 6
Vitex® Gripper Paper
Orange/Blue Flared End PVC Tubing 0.25 i.d. – Qty. 12 Part No.
N0774067
N0777466
N0777465
N0777463
N0777436
N0777437
N0777061
Non HF-Resistant Internal Standard Kit (Includes items listed below)
EzyFit Glass Mixing T-piece
Internal Standard Sample Probe
EzyFit Sample Tube – Twin
EzyFit with 1/16 inch o.d. x 0.50 mm i.d. x 700 mm long sample tube
EzyFit with 1/16 inch o.d. x 0.25 mm i.d. x 700 mm long sample tube
UniFit-EzyFit Sample Tube – Qty. 6
Vitex® Gripper Paper
Orange/Blue Flared End PVC Tubing 0.25 i.d. – Qty. 12
N0774068
N0777461
N0777465
N0777462
N0777436
N0777437
N0777061
N0773112
N0773112
NexION Consumables Kits
Part No.
NexION 300Q/X/D and 350Q/X/D Consumables Kit
N8140513
Typical one year’s supply of consumables. Consists of the following parts:
Description
Demountable Quartz Torch
Load Coil
Quartz Ball Joint Injector 2.0 mm i.d.
Cassette Torch Injector Support Adapter for Ball Joint Injectors
Glass Cyclonic Spray Chamber
Nickel Skimmer Cone
Nickel Sampler Cone
Hyper Skimmer Cone
Sampler Cone Gasket Hyper Skimmer O-Ring
Hyper Skimmer Screw Santoprene® 1.30 mm Gray/Gray Pump Tubing
Flared PVC 0.38 mm Green/Orange Pump Tubing
Drain Tubing (feet)
Sample Uptake Tubing (cm)
Instrument Filter (left)
Instrument Filter (back right)
Spray Chamber Drain Fitting
Nebulizer Fitting
Male Barb CTFE Fittting
Female Barb CTFE Fitting
Qty
2
1
2
1
1
2
2
1
3
2
2
4
4
6
12
2
2
2
2
2
2
Part No. N8122006
WE021816
WE023948
W1012406
N8145014
W1026356
W1033612
W1033995
W1040148
09902123
WE027484
N0777444
N0777042
02506495
WE024375
W1036712
W1036713
N8145015
N8145016
N8145017
N8145018
Part No.
NexION 300S and 350S Consumables Kit
N8140514 Typical one year’s supply of consumables. Consists of the following parts:
Description
Demountable Quartz Torch
Load Coil
Quartz Ball Joint Injector 2.0 mm i.d.
Cassette Torch Injector Support Adapter for Ball Joint Injectors
Quartz Cyclonic Spray Chamber
Platinum Skimmer Cone
Platinum Sampler Cone
Hyper Skimmer Cone
Sampler Cone Gasket Hyper Skimmer O-Ring
Hyper Skimmer Screw Santoprene® 1.30 mm Gray/Gray Pump Tubing
Flared PVC 0.38 mm Green/Orange Pump Tubing
Drain Tubing (feet)
Sample Uptake Tubing (cm)
Instrument Filter (left)
Instrument Filter (back right)
Spray Chamber Drain Fitting
Nebulizer Fitting
Male Barb CTFE Fittting
Female Barb CTFE Fitting
Qty
2
1
2
1
1
1
1
1
3
2
2
4
4
6
12
1
1
2
2
2
2
Part No. N8122006
WE021816
WE023948
W1012406
N8145013
W1026907
W1033614
W1033995
W1040148
09902123
WE027484
N0777444
N0777042
02506495
WE024375
W1036712
W1036713
N8145015
N8145016
N8145017
N8145018
5
Autosampler Tubes
Autosampler Tubes with Caps
Capacity
Size
Type
Qty
Part No.
15 mL
17 mm x 120 mm
Conical Bottom
500
B0193233
50 mL
28 mm x 115 mm
Conical/Freestanding
500
B0193234
Other Replacement Parts
Replacement Parts
1
Description
Metal Spill Tray for vacuum pump
UV Shield/Spray Chamber Nut
Instrument Filter (left)
Instrument Filter (back right)
Vacuum Pump Fluid – Fomblin® GV80 1 L
1 NexION Sample Tray
Sample Spill Tray
Part No. N8145022
W1037267
W1036712
W1036713
N8145003
N8141206
W1037577
Standards
PerkinElmer Pure and Pure Plus Standards
Matrix
Contents
Vol.
Part No. NexION 300Q and 350Q Solution kit –non-cell
N8140503
Solution Kit (Includes items listed below)
NexION Wash Solution
250 mL
N8145050
NexION Setup Solution
500 mL
N8145051
NexION 300Q and 350Q Non-cell Stability Solution
500 mL
N8145053
NexION Standard/DRC Mode Detection Limit Blank Solution
100 mL
N8145055
NexION Standard/DRC Mode Detection Limit Solution
100 mL
N8145056
NexION Dual Detector Solution
100 mL
N8145059
NexION 300X/D/S and 350X/D/S Solution kit – cell instruments
N8140504
Solution Kit (Includes items listed below)
NexION Wash Solution
250 mL
N8145050
NexION Setup Solution
500 mL
N8145051
NexION KED Setup Solution
250 mL
N8145052
NexION 300X/D/S and 350X/D/S Cell Stability Solution
500 mL
N8145054
NexION Standard/DRC Mode Detection Limit Blank Solution
100 mL
N8145055
NexION Standard/DRC Mode Detection Limit Solution
100 mL
N8145056
NexION KED Mode Detection Limit Blank Solution
100 mL
N8145057
NexION KED Mode Detection Limit Solution
100 mL
N8145058
NexION Dual Detector Solution
100 mL
N8145059
6
Standards, continued
PerkinElmer Pure and Pure Plus Standards, continued
Matrix
Contents
Vol.
Part No. NexION Setup Solution
1% HNO3
1 µg/L: Be, Ce, Fe, In, Li, Mg, Pb, U 500 mL
N8145051
NexION KED Setup Solution
1% HCl
10 µg/L: Co
250 mL
N8145052
1 µg/L: Ce
NexION 300Q and 350Q Non-cell Stability Solution
1% HNO3
1 µg/L: Cd, Cu, Mg, Pb 500 mL
N8145053
NexION 300X/D/S and 350X/D/S Cell Stability Solution
1% HNO3
1 µg/L: Cd, Cr, Fe, In, Mg, Pb 500 mL
10 µg/L: Co, Cu, Se N8145054
NexION Standard/DRC Mode Detection Limit Blank Solution
0.5% HNO3
100 mL
N8145055
NexION Standard/DRC Mode Detection Limit Solution
0.5% HNO3
1 µg/L: Be, Ca, Co, Fe, In, U
100 mL
N8145056
NexION KED Mode Detection Limit Blank Solution
1% HCl
100 mL
N8145057
NexION KED Mode Detection Limit Solution
1% HCl
10 µg/L: V, As, Se
100 mL
N8145058
NexION Dual Detector Solution
2% HNO3
200 µg/L: Al, Ba, Ce, Co, Cu, In, Li, Mg, Mn, Ni, Pb, Tb, U, Zn 100 mL
N8145059
NexION AFT Single-Element Solution
2% HNO3
2 µg/L: Fe
100 mL
N8145060
NexION AFT Multi-Element Solution
2% HNO3
2 µg/L: Ag, Al, As, Ba, Be, Bi, Ca, Cd, Co, Cr, Cs,
100 mL
N8145061
Cu, Fe, Ga, In, K, Li, Mg, Mn, Na, Ni, Pb, Rb, Se,
Sr, Tl, U, V, Zn
NexION Wash Solution
1% HNO3
250 mL
N8145050
Internal Standard Mix
5-10% HNO3
10 µg/mL: 6Li, Sc, Ge, Y, In, Tb, Bi
125 mL
N9303832
Multi-Element Internal Standard
2% HNO3 10 µg/mL: Bi, Ho, In, 6Li, Sc, Tb, Y
125 mL
N9303834
Quality Control Standard – 21 Elements
5% HNO3/tr Tartaric Acid/tr HF
125 mL
N9300281
100 µg/mL: As, Be, Ca, Cd, Co, Cr, Cu, Fe, Li, Mg,
Mn, Mo, Ni, Pb, Sb, Se, Sr, Ti, Tl, V, Zn
Instrument Calibration Standard 2
5% HNO3/tr Tartaric Acid/tr HF
100 mg/L: Ag, Al, As, Ba, Be, Ca, Cd, Co, Cr, Cu,
Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Sb, Se, Sn, Sr, Ti,
Tl, V, Zn
125 mL
N9301721
7
Standards, continued
Gold Nanoparticle Standards
Description
Diameter
(nm)
Number of
Particles/mL
Volume
(mL)
Part No.
30 nm Spherical Au Nanoparticle in DI Water
30
2.00E+11
25
N8142300
40 nm Spherical Au Nanoparticle in DI Water
40
8.70E+10
25
N8142301
50 nm Spherical Au Nanoparticle in DI Water
50
4.50E+10
25
N8142302
60 nm Spherical Au Nanoparticle in DI Water
60
2.60E+10
25
N8142303
70 nm Spherical Au Nanoparticle in DI Water
70
1.60E+10
25
N8142304
80 nm Spherical Au Nanoparticle in DI Water
80
1.10E+10
25
N8142305
90 nm Spherical Au Nanoparticle in DI Water
90
7.80E+09
25
N8142306
100 nm Spherical Au Nanoparticle in DI Water
100
5.70E+09
25
N8142307
Visit www.perkinelmer.com/standards for our complete selection of Inorganic Standards.
For a complete listing of consumables and supplies, please visit www.perkinelmer.com/icpmssupplies
PerkinElmer, Inc.
940 Winter Street
Waltham, MA 02451 USA
P: (800) 762-4000 or
(+1) 203-925-4602
www.perkinelmer.com
For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs
Copyright ©2010-2014, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners.
009071J_01