Consumables and Supplies NexION® 300/350 ICP-MS Sampler and Skimmer Cones Precision-designed and manufactured, large-orifice sampler and skimmer cones provide superior long-term stability and resist clogging, allowing analysis under both high and low sample-uptake conditions. Nickel is a very rugged, long-lasting material for the majority of sample types, while platinum is the material of choice for more corrosive samples. They have been designed to maximize signal stability and to minimize clogging during extended runs of samples containing high dissolved solids. Nickel Sampler and Skimmer Cones Type Sampler Skimmer Part No. W1033612 W1026356 Platinum Sampler and Skimmer Cones Type Sampler Skimmer Part. No. W1033614 W1026907 Hyper Skimmer Cone Type Hyper Skimmer Part No. W1033995 Replacement Parts Description Sampler Gasket Hyper Skimmer O-Ring Hyper Skimmer Screw Cone Removal Tool Torch Alignment Tool Part No. W1040148 09902123 WE027484 W1034694 WE015554 Torches Part No. Demountable Quartz Torch N8122006 The EasyGlide™ torch mount and alignment system for the NexION ICP-MS is a demountable design that incorporates a quartz torch with a fully replaceable sample injector made of fused alumina, quartz or sapphire. High Efficiency Demountable Quartz Torch Part No. N8145318 Operates at 25% reduced argon gas flows compared to the standard Demountable Quartz Torch (N8122006). Nebulizers MEINHARD® Nebulizers The MEINHARD® Concentric Nebulizer reflects exacting standards in design and manufacturing. Its advantages include simplicity of design and operation, reproducible and self-aligning aerosol, and close fabrication control. They provide excellent sensitivity and precision for aqueous solutions and samples with few dissolved solids (less than 1%). MEINHARD® Nebulizers are self-aspirating. Model Type A Type C Material Quartz Glass AR Flow Rate 1.0 L/min 1.0 L/min Uptake Rate 0.5 mL/min, 50 psig 0.5 mL/min, 50 psig Part No. N8145011 N81450 12 Spray Chambers The Cyclonic Spray Chamber relies on momentum to efficiently and quickly remove the larger droplets from the sample mist decreasing any opportunity for occlusion or agglomeration of the smaller droplets. The result is higher efficiency, better precision and faster washouts than other spray chamber designs. For use with ball joint injectors. • Decreased sample introduction system installation and optimization time due to the preset nature of the spray chamber/nebulizer combination • More samples per hour due to minimal dead volume and efficient draining Type Quartz Cyclonic Spray Chamber Glass Cyclonic Spray Chamber Replacement Spray Chamber Nut PFA Spray Chamber with PFA End Cap (Requires PFA body injector N8122411 or N8122412 or N8122413) PFA 6 mm Secure Replacement Nut for Quartz Cyclonic Spray Chambers Part No. N8145013 N8145014 N8141420 N8142000 N8141420 Adapters, Fittings and O-Rings Adapters and Fittings Description 1 Nebulizer Fitting 1 2 Spray Chamber Drain Fitting 3 Male barb CTFE Fitting 4 Female barb CTFE Fitting 2 4 2 3 Part No. N8145016 N8145015 N8145017 N8145018 Adapters, Fittings and O-Rings, continued O-Rings Description Qty Part No. Injector Adapter Kit (Includes items listed below) Adapter 1 O-Ring 3/8 inch i.d. x 1/16 inch 1 O-Ring 1/4 inch i.d. x 1/16 inch 1 Injector Spacer 1 Injector Nut 1 N8140360 W1012406 W1008572 W1008573 W1012409 W1012408 Injector Adapter Kit 2 (Includes items listed below) Injector O-Ring 0.239 i.d. x 0.070 WD 1 O-Ring 0.551 i.d. x 0.070 WD 1 O-Ring 3/8 inch i.d. x 1/16 inch 1 Adapter 1 Injector Nut 1 Injector Spacer 1 O-Ring 5/8 inch i.d. x 1/8 inch WD 1 N8140527 09210011 N8122010 W1008572 W1012406 W1012408 W1012409 W1013545 O-Ring Kit for Injector Support (Includes items listed below) Injector O-Ring 0.239 i.d. x 0.070 WD 2 Torch O-Ring 0.364 i.d. x 0.070 WD 2 O-Ring 0.551 i.d. x 0.070 WD 1 O-Ring 5/8 inch i.d. x 1/8 inch WD 1 N8120100 09210011 09210012 N8122010 W1013545 Injectors Alumina Injectors for use with Ryton® sample introduction system Alumina injectors provide economical HF resistance. They are vacuum baked to reduce contamination. For use only with HF resistant (Ryton®) sample introduction system. • 2.0 mm i.d. for aqueous solutions and less volatile organic solvents • 1.5 mm i.d. for reduced sample loading • 0.85 mm i.d. for use with volatile organic solutions Dimension 2.0 mm i.d. 1.5 mm i.d. 0.85 mm i.d. Part No. N8126041 N8126040 N8126039 Sapphire Injectors for use with Ryton® sample introduction system Dimension 2.0 mm i.d. Part No. N0695495 Quartz Injectors for use with Ryton® sample introduction system Dimension 1.2 mm i.d. 1.6 mm i.d. 2.0 mm i.d. Part No. N0681631 00473292 N8125029 Quartz Ball Joint Injectors Dimension 0.85 mm i.d. 1.5 mm i.d. 2.0 mm i.d. (standard with NexION instrument) Part No. WE027030 WE027005 WE023948 Support Adapters Description Cassette Torch Injector Support Adapter for non-ball joint injectors Cassette Torch Injector Support Adapter for ball joint injectors Part No. W1013266 W1012406 3 Sample Introduction Kits PC3 / PC3-LT Peltier Coolers with Oxygen Port The PC3 has two preset temperatures +2 ˚C / -5 ˚C and is ideal when running aqueous or aqueous/organic mixtures. The PC3-LT operates at -20 ˚C when running 100% volatile organic solvents to reduce the solvent load on the plasma. Includes Quartz spray chamber with additional gas port. Description PC3 Organic Sample Introduction Kit PC3-LT Organic Sample Introduction Kit Temperature +2 ˚C / -5 ˚C +2 ˚C / -20 ˚C Spray Chamber Quartz Quartz Part No. N8142003 N8145099 Other Sample Introduction Kits Description PFA-Platinum HF-Resistant Sample Introduction Kit PFA-Sapphire HF-Resistant Sample Introduction Kit HF Sample Introduction Kit (Ryton®) Part No. N8142001 N8142002 N8140507 Detectors SimulScan Dual-Stage Detector The dual-stage detector is an integral part of the NexION ICP-MS SimulScan™ system. This electron multiplier measures both high- and low-level analytes simultaneously. This conserves valuable or limited samples, eliminates the need to perform timeconsuming sample dilutions and allows you to quickly characterize unknown samples. Description NexION 300/350 ICP-MS Detector Part No. N8145000 Tubing Peristaltic Pump Tubing Description i.d. (mm) Santoprene®1.30 Flared PVC 0.19 Flared PVC 0.25 Flared PVC 0.38 Stop Colors Gray/Gray Orange/Red Orange/Blue Green/Orange Part No. N0777444 N0773111 N0773112 N0777042 Additional Tubing Description Sample Uptake Tubing (cm) Drain Tubing (feet) Torch Box Drain Assembly Part No. WE024375 02506495 N8140506 Internal Standards Kits 4 Description HF-Resistant Internal Standard Kit (Includes items listed below) HF Mixing T-piece Internal Standard Sample Probe EzyFit Sample Tube 0.5 mm i.d. EzyFit with 1/16 inch o.d. x 0.50 mm i.d. x 700 mm long sample tube EzyFit with 1/16 inch o.d. x 0.25 mm i.d. x 700 mm long sample tube UniFit-EzyFit Sample Tube – Qty. 6 Vitex® Gripper Paper Orange/Blue Flared End PVC Tubing 0.25 i.d. – Qty. 12 Part No. N0774067 N0777466 N0777465 N0777463 N0777436 N0777437 N0777061 Non HF-Resistant Internal Standard Kit (Includes items listed below) EzyFit Glass Mixing T-piece Internal Standard Sample Probe EzyFit Sample Tube – Twin EzyFit with 1/16 inch o.d. x 0.50 mm i.d. x 700 mm long sample tube EzyFit with 1/16 inch o.d. x 0.25 mm i.d. x 700 mm long sample tube UniFit-EzyFit Sample Tube – Qty. 6 Vitex® Gripper Paper Orange/Blue Flared End PVC Tubing 0.25 i.d. – Qty. 12 N0774068 N0777461 N0777465 N0777462 N0777436 N0777437 N0777061 N0773112 N0773112 NexION Consumables Kits Part No. NexION 300Q/X/D and 350Q/X/D Consumables Kit N8140513 Typical one year’s supply of consumables. Consists of the following parts: Description Demountable Quartz Torch Load Coil Quartz Ball Joint Injector 2.0 mm i.d. Cassette Torch Injector Support Adapter for Ball Joint Injectors Glass Cyclonic Spray Chamber Nickel Skimmer Cone Nickel Sampler Cone Hyper Skimmer Cone Sampler Cone Gasket Hyper Skimmer O-Ring Hyper Skimmer Screw Santoprene® 1.30 mm Gray/Gray Pump Tubing Flared PVC 0.38 mm Green/Orange Pump Tubing Drain Tubing (feet) Sample Uptake Tubing (cm) Instrument Filter (left) Instrument Filter (back right) Spray Chamber Drain Fitting Nebulizer Fitting Male Barb CTFE Fittting Female Barb CTFE Fitting Qty 2 1 2 1 1 2 2 1 3 2 2 4 4 6 12 2 2 2 2 2 2 Part No. N8122006 WE021816 WE023948 W1012406 N8145014 W1026356 W1033612 W1033995 W1040148 09902123 WE027484 N0777444 N0777042 02506495 WE024375 W1036712 W1036713 N8145015 N8145016 N8145017 N8145018 Part No. NexION 300S and 350S Consumables Kit N8140514 Typical one year’s supply of consumables. Consists of the following parts: Description Demountable Quartz Torch Load Coil Quartz Ball Joint Injector 2.0 mm i.d. Cassette Torch Injector Support Adapter for Ball Joint Injectors Quartz Cyclonic Spray Chamber Platinum Skimmer Cone Platinum Sampler Cone Hyper Skimmer Cone Sampler Cone Gasket Hyper Skimmer O-Ring Hyper Skimmer Screw Santoprene® 1.30 mm Gray/Gray Pump Tubing Flared PVC 0.38 mm Green/Orange Pump Tubing Drain Tubing (feet) Sample Uptake Tubing (cm) Instrument Filter (left) Instrument Filter (back right) Spray Chamber Drain Fitting Nebulizer Fitting Male Barb CTFE Fittting Female Barb CTFE Fitting Qty 2 1 2 1 1 1 1 1 3 2 2 4 4 6 12 1 1 2 2 2 2 Part No. N8122006 WE021816 WE023948 W1012406 N8145013 W1026907 W1033614 W1033995 W1040148 09902123 WE027484 N0777444 N0777042 02506495 WE024375 W1036712 W1036713 N8145015 N8145016 N8145017 N8145018 5 Autosampler Tubes Autosampler Tubes with Caps Capacity Size Type Qty Part No. 15 mL 17 mm x 120 mm Conical Bottom 500 B0193233 50 mL 28 mm x 115 mm Conical/Freestanding 500 B0193234 Other Replacement Parts Replacement Parts 1 Description Metal Spill Tray for vacuum pump UV Shield/Spray Chamber Nut Instrument Filter (left) Instrument Filter (back right) Vacuum Pump Fluid – Fomblin® GV80 1 L 1 NexION Sample Tray Sample Spill Tray Part No. N8145022 W1037267 W1036712 W1036713 N8145003 N8141206 W1037577 Standards PerkinElmer Pure and Pure Plus Standards Matrix Contents Vol. Part No. NexION 300Q and 350Q Solution kit –non-cell N8140503 Solution Kit (Includes items listed below) NexION Wash Solution 250 mL N8145050 NexION Setup Solution 500 mL N8145051 NexION 300Q and 350Q Non-cell Stability Solution 500 mL N8145053 NexION Standard/DRC Mode Detection Limit Blank Solution 100 mL N8145055 NexION Standard/DRC Mode Detection Limit Solution 100 mL N8145056 NexION Dual Detector Solution 100 mL N8145059 NexION 300X/D/S and 350X/D/S Solution kit – cell instruments N8140504 Solution Kit (Includes items listed below) NexION Wash Solution 250 mL N8145050 NexION Setup Solution 500 mL N8145051 NexION KED Setup Solution 250 mL N8145052 NexION 300X/D/S and 350X/D/S Cell Stability Solution 500 mL N8145054 NexION Standard/DRC Mode Detection Limit Blank Solution 100 mL N8145055 NexION Standard/DRC Mode Detection Limit Solution 100 mL N8145056 NexION KED Mode Detection Limit Blank Solution 100 mL N8145057 NexION KED Mode Detection Limit Solution 100 mL N8145058 NexION Dual Detector Solution 100 mL N8145059 6 Standards, continued PerkinElmer Pure and Pure Plus Standards, continued Matrix Contents Vol. Part No. NexION Setup Solution 1% HNO3 1 µg/L: Be, Ce, Fe, In, Li, Mg, Pb, U 500 mL N8145051 NexION KED Setup Solution 1% HCl 10 µg/L: Co 250 mL N8145052 1 µg/L: Ce NexION 300Q and 350Q Non-cell Stability Solution 1% HNO3 1 µg/L: Cd, Cu, Mg, Pb 500 mL N8145053 NexION 300X/D/S and 350X/D/S Cell Stability Solution 1% HNO3 1 µg/L: Cd, Cr, Fe, In, Mg, Pb 500 mL 10 µg/L: Co, Cu, Se N8145054 NexION Standard/DRC Mode Detection Limit Blank Solution 0.5% HNO3 100 mL N8145055 NexION Standard/DRC Mode Detection Limit Solution 0.5% HNO3 1 µg/L: Be, Ca, Co, Fe, In, U 100 mL N8145056 NexION KED Mode Detection Limit Blank Solution 1% HCl 100 mL N8145057 NexION KED Mode Detection Limit Solution 1% HCl 10 µg/L: V, As, Se 100 mL N8145058 NexION Dual Detector Solution 2% HNO3 200 µg/L: Al, Ba, Ce, Co, Cu, In, Li, Mg, Mn, Ni, Pb, Tb, U, Zn 100 mL N8145059 NexION AFT Single-Element Solution 2% HNO3 2 µg/L: Fe 100 mL N8145060 NexION AFT Multi-Element Solution 2% HNO3 2 µg/L: Ag, Al, As, Ba, Be, Bi, Ca, Cd, Co, Cr, Cs, 100 mL N8145061 Cu, Fe, Ga, In, K, Li, Mg, Mn, Na, Ni, Pb, Rb, Se, Sr, Tl, U, V, Zn NexION Wash Solution 1% HNO3 250 mL N8145050 Internal Standard Mix 5-10% HNO3 10 µg/mL: 6Li, Sc, Ge, Y, In, Tb, Bi 125 mL N9303832 Multi-Element Internal Standard 2% HNO3 10 µg/mL: Bi, Ho, In, 6Li, Sc, Tb, Y 125 mL N9303834 Quality Control Standard – 21 Elements 5% HNO3/tr Tartaric Acid/tr HF 125 mL N9300281 100 µg/mL: As, Be, Ca, Cd, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Ni, Pb, Sb, Se, Sr, Ti, Tl, V, Zn Instrument Calibration Standard 2 5% HNO3/tr Tartaric Acid/tr HF 100 mg/L: Ag, Al, As, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Mo, Na, Ni, Pb, Sb, Se, Sn, Sr, Ti, Tl, V, Zn 125 mL N9301721 7 Standards, continued Gold Nanoparticle Standards Description Diameter (nm) Number of Particles/mL Volume (mL) Part No. 30 nm Spherical Au Nanoparticle in DI Water 30 2.00E+11 25 N8142300 40 nm Spherical Au Nanoparticle in DI Water 40 8.70E+10 25 N8142301 50 nm Spherical Au Nanoparticle in DI Water 50 4.50E+10 25 N8142302 60 nm Spherical Au Nanoparticle in DI Water 60 2.60E+10 25 N8142303 70 nm Spherical Au Nanoparticle in DI Water 70 1.60E+10 25 N8142304 80 nm Spherical Au Nanoparticle in DI Water 80 1.10E+10 25 N8142305 90 nm Spherical Au Nanoparticle in DI Water 90 7.80E+09 25 N8142306 100 nm Spherical Au Nanoparticle in DI Water 100 5.70E+09 25 N8142307 Visit www.perkinelmer.com/standards for our complete selection of Inorganic Standards. For a complete listing of consumables and supplies, please visit www.perkinelmer.com/icpmssupplies PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs Copyright ©2010-2014, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 009071J_01