© Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 1100 F ■ Overview ■ Integration The complete flowmeter consists of a sensor and an associated transmitter SITRANS F M MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to a variety of fieldbus systems such as PROFIBUS DP and PA, Modbus RTU/RS 485, HART, FOUNDATION Fieldbus H1, DeviceNet. Pressure/temperature curve; material AISI 316L/1.4404 3 Pressure/temperature curve; material AISI 316L/1.4404 bar 45 PN 40 40 35 30 PN 25 25 20 PN 16 15 10 PN 6 5 0 The electromagnetic sensor SITRANS F M MAG 1100 F is designed to meet applications in the food and beverage industry. 0 20 40 60 °C 80 100 120 140 160 180 200 Pressure/temperature curve; material AISI 316L/1.4404 ■ Benefits • Sensor sizes: DN 10 to DN 100 (3/8” to 4”) • AISI 316 stainless steel enclosure • Sensor: Hygienic connection, 3A approval and EHEDG certified • Sanitary design for CIP / SIP cleaning • Conforms to FDA • Easy commissioning, the SENSORPROM unit automatically updates settings • Hose proof IP67/NEMA 4X enclosure rating • Designed that patented in-situ verification can be conducted. Using SENSORPROM fingerprints ■ Application The main applications of the SITRANS F M electromagnetic sensors can be found in the following fields: • Food industry • Beverage industry • Pharmaceutical industry ■ Design • Unique mechanical design with a wide range of customer specified sanitary connection • Compact or remote mounting possible easy "plug & play" field changeable • Simple on site upgrade to IP68/NEMA 6P terminal box • Ex ATEX 2G D version for hazardous areas (ceramic liner) ■ Mode of operation The flow measuring principle is based on Faraday’s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to the velocity of the flow. 3/58 -20 Siemens FI 01 · 2016 Pressure/temperature curve; material AISI 316L/1.4404 psi 700 PN 40 600 500 400 PN 25 300 PN 16 200 PN 6 100 0 0 50 100 150 200 250 300 350 °F 400 For further information on the PED standard and requirements, see page 9/6. © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 1100 F ■ Technical specifications Measuring principle Excitation frequency (Mains supply: 50 Hz/60 Hz) Process connection Nominal size Process connection Rated operating conditions Ambient conditions Ambient temperature1) • Sensor • Ex sensor • Compact transmitter MAG 5000/60002) • Transmitter MAG 6000 I • Compact transmitter MAG 6000 I Ex Electromagnetic induction DN 10 ... 65 (¼“ … 2½”): 12.5 Hz/15 Hz DN 80 ... 100 (3”, 4”): 6.25 Hz/7.5 Hz Design Weight Enclosure • MAG 1100 F DN 10 … DN 100 (3/8" … 4") Hygienic adapters available for: • Direct welding onto pipe • Clamp fitting • Threaded fitting -20 … +60 °C (-4 … +140 °F) -20 … +60 °C (-4 … +140 °F) • Standard • Option Fibre glass reinforced polyamide Stainless steel AISI 316/1.4436 • Ex ATEX (remote version only) Stainless steel AISI 316/1.4436 MAG 1100 F (PFA) -20 … +150 °C (-4 … +302 °F) Suitable for steam sterilization MAG 1100 F (PFA) -30 … +130 °C (-22 … +266 °F) Suitable for steam steralization at 150 °C (302 °F) MAG 1100 F (Ceramic) Platinum with gold /Titanium brazing alloy MAG 1100 F (PFA) • DN 10 ... 15 (3/8" ... ½"): Hastelloy C276/2.4819 • DN 25 ... 100 (1" ... 4"): Hastelloy C22/2.4602 Cable entries • Remote installation 2 x M20 or 2 x ½" NPT • Compact installation - MAG 5000/MAG 6000: 4 x M20 or 4 x ½" NPT - MAG 6000 I: 2 x M25 (for supply/output) - MAG 6000 I Ex: 2 x M25 (for supply/output) Temperature shock MAG 1100 F • Duration 1 min, followed by 10 min rest MAG 1100 F (PFA) Operating pressure MAG 1100 F (Ceramic) MAG 1100 F (PFA) Mechanical load (vibration) Enclosure rating EMC • DN 10, 15, 25: Max. T 80 °C/min (3/8”, ½”, 1”: Max. T 144 °F/min) • DN 40, 50, 65: Max. T 70 °C/min (1½”, 2”, 2½”: Max. T 126 °F/min) • DN 80, 100: Max. T 60 °C/min (3”, 4”: Max. T 108 °F/min) Max. 100 °C (212 °F) momentarily DN 10 ... 65: 40 bar (3/8” … 2½”: 580 psi) DN 80: 25 bar (3”: 363 psi) DN 100: 25 bar (4”: 363 psi) Vacuum: 1 x 10-6 barabs (1.5 x 10-5 psiabs) 20 bar (290 psi) Vacuum: 0.02 barabs (0.3 psiabs) DN 80 ... DN 100: CO2 pressure max. 7 bar (101.5 psi) 18 ... 1000 Hz random in x, y z, directions for 2 hours according to EN 60068-2-36 Sensor: 3.17 g RMS Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 g RMS. Sensor with compact MAG 6000 I/MAG 6000 I Ex mounted transmitter: 1.14 g RMS For compact installation with the MAG 6000 I/MAG 6000 I Ex, transmitter to be supported to avoid tension on sensor part. IP67 to EN 60529 (NEMA 4X), 1 mH2O for 30 min 2014/30/EU Aluminum oxide Al2O3 (ceramics) Reinforced PFA (teflon) (not for Ex) Electrodes Temperature of medium MAG 1100 F (Ceramic) Stainless steel AISI 316L/1.4404 Terminal box (remote version only) Liner MAG 1100 F (Ceramic) -40 … +100 °C (-40 … +212 °F) -20 … +60 °C (-4 … +140 °F) -20 … +60 °C (-4 … +140 °F) See Dimensional drawings Material Certificates and approvals Calibration • Standard Production calibration, Zero-point, 2 x 25 %, 2 x 90 % calibration report shipped with sensor MAG 1100 F (Ceramic) 3A (sensor with Polyamide terminal box and FKM/FPM or EPDM gaskets), transmitter not part of the approval • Ex ATEX approvals for sensor or compact with MAG 6000 I Ex • Sensor with/without MAG 5000/6000/6000 I ATEX 2G D sensor EEx d e ia IIB T3 - T6 FM Class I, Div 2 MAG 1100 F (PFA) 3A (sensor with Polyamide terminal box with EPDM gasket), transmitter not part of the approval EHEDG certified (use EPDM gasket) (DN 25 ... 100 (1 ... 4")) FM Class I, Div 2 Hygienic EC 1935:2004 European food contact material Material certificate EN 10204 3.1 Available when ordering together with meter3) Pressure test certificate Available when ordering together with meter3) Conforms to • PED – 2014/68/EU4) • FDA Custody transfer approvals (MAG 5000/6000 CT) • Cold water pattern approval PTB (Germany) • Other media than water pattern approval- OIML R 117 (Denmark) 1) Conditions are also dependent on liner characteristics. With compact transmitter MAG 5000 CT/6000 CT -20 ... +50 °C (-4 ... +122 °F) 3) Has to be ordered with the meter. It is not possible to order the certificate afterwards. 4) For further information on the PED standard and requirements, see page 9/6. 2) Siemens FI 01 · 2016 3/59 3 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 1100 F 3 Accessories Selection and Ordering data Article No. Weld-in adapter Sensor SITRANS F M MAG 1100 F 7 ME 6 1 4 0 - Adapter for welding onto dairy pipe, stainless steel 1.4404 Tri-Weld, ISO 2037, DIN 11850, SMS 3008, BS 4825-1 • DN 10, 15, 25, 40, 50 and 65 (3/8”, ½”, 1”, 1½”, 2”and 2½”) PN 40 (600 psi) • DN 80 and DN 100 (3" and 4”) PN 25 (350 psi) Clamp adapter Tri-Clamp, ISO 2852, DIN 32676, SMS 3016, BS 4825-3 DN 10, 15, 25, 40 and 50 (3/8”, ½”, 1”, 1½”, and 2”) PN 16 (200 psi) DN 65, 80 and 100 (2½”, 3” and 4”) PN 10 (150 psi) Thread adapter DIN 11851 • DN 10, 15, 25, and 40 (3/8”, ½”, 1”, and 1½”) PN 40 (600 psi) • DN 50, 65, 80 and 100 (2”, 2½”, 3” and 4”) PN 25 (350 psi) DN 80 (3“) DN 100 (4“) 3M 3T Process connections B C D E Clamp type DIN 32676 ISO 2852 (SMS 3016) BS 4825-3 Tri-Clamp G H J K Stainless steel AISI 316/1.4436 Threaded type DIN 11851 SMS 11451) M N FKM/FPM with stainless steel insert (AISI 304/1.4301) (-20 ... +150 °C (-4 ... +302 °F)) Liner material PFA (not for Ex) Ceramic EPDM (-20 ... +150 °C (-4 ... +302 °F)) Gasket material1) EPDM flat gasket (FDA, 3A) FPM/FKM (FDA, 3A) (only with ceramic liner) EPDM-P gasket (only for PFA) (FDA, EHEDG certified, 3A) PN 16 (200 psi) PN 6 (80 psi) Gasket • MAG 1100 F (PFA) 2R 2Y 3F A Design • MAG 1100 F (Ceramic) DN 40 (1½“) DN 50 (2“) DN 65 (2½“) Material Adapter 1R 1V 2D Weld in DIN 11850 ISO 2037 (SMS 3008) BS 4825-1 Tri-Weld SMS 1145 • DN 25, 40, 50, 65 and 80 (1”, 1½”, 2”, 2½” and 3”) Diameter DN 10 (3/8“) DN 15 (½“) DN 25 (1“) No adaptors (specials see accessories) ISO 2853, BS 4825-4 • DN 10, 15, 25, 40, 50, 65 and 80 (3/8”, ½”, 1”, 1½”, 2”, 2½ and 3”) 77777 - 7777 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. EPDM (-20 ... +150 °C (-4 ... +302 °F)) NBR (-20 ... +100 °C (-4 ... +212 °F)) Note: When combined sensor and adapter, the operating pressure is the lower rated of the pair. Electrode material Hastelloy C (only with PFA liner) Platinum (only with ceramic liner) Transmitter Standard sensor for remote transmitter (order transmitter separately), 3A Ex sensor for remote transmitter (order transmitter separately) 3A MAG 6000 I, Alu.18 ... 90 V DC, 115 ... 230 V AC MAG 6000 I, Aluminum 18 ... 30 V DC, Ex 1 2 A B C D E H J K L Communication No communication, add-on possible HART PROFIBUS PA Profile 3 (only MAG 6000/MAG 6000 I) PROFIBUS DP Profile 3 (not for Ex) (only MAG 6000/MAG 6000 I) Modbus RTU/RS 485 (not for Ex) (only MAG 6000/MAG 6000 I) FOUNDATION Fieldbus H1 (only MAG 6000/MAG 6000 I) 1) Siemens FI 01 · 2016 0 2 3 MAG 6000 I, Aluminum 115 ... 230 V AC, Ex MAG 6000, Polyamide, 11 ... 30 V DC/11 ... 24 V AC MAG 6000, Polyamide, 115 ... 230 V AC MAG 5000, Polyamide, 11 ... 30 V DC/ 11 ... 24 V AC MAG 5000, Polyamide, 115 ... 230 V AC 3/60 1 2 SMS 1145 standard is not approved by 3A A B F G E J © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 1100 F Selection and Ordering data Article No. Operating instructions for SITRANS F M MAG 1100F Sensor SITRANS F M MAG 1100 F 7 ME 6 1 4 0 - Description Article No. 77777 - 7777 • English A5E02435647 Cable glands/terminal box Metric: Polyamide terminal box or 6000 I compact ½" NPT: Polyamide terminal box or 6000 I compact Metric: SS terminal box (mandatory for Stainless steel MAG 6000 Transmitter) ½" NPT: SS terminal box (mandatory for Stainless steel MAG 6000 Transmitter) 1 2 3 4 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Selection and Ordering data Order code This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation MAG 5000/6000 transmitters and sensors are packed in separate boxes, the final assembly takes place during installation at the customer's place. MAG 6000 I/MAG 6000 I Ex ATEX 2G D transmitters and sensors are delivered compact mounted from factory. Communication module will be pre-mounted in the transmitter. Please use online Product selector to get latest updates. Product selector link: www.pia-portal.automation.siemens.com Additional information Please add “-Z“ to Article No. and specify Order code(s) and plain text. Accessories Customer-specific converter setup Y20 Tag name plate, stainless steel fixed with SS wire (add plain text) Y17 Description Tag name plate, plastic (self adhesive) Y18 Pressure test certificate according to EN 10204-3.1 C01 Potting kit for terminal box of flow sensors for IP68/NEMA 6P Material certificate according to EN 10204-3.1 C12 Factory certificate according to EN 10204-2.2 C14 Factory certificate according to EN 10204-2.1 C15 , Article No. FDK:085U0220 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Region specific approvals and certificates • KCC label W28 Terminal blocks • Factory mounted terminal blocks N02 Sensor cables wired (specify cable Article No.) Y40 Sensor for remote transmitter's junction box potted with wired cable (specify cable Article No.) (not for Ex sensors) Y41 Other postproduction requirements (add desired text) Y99 Additional calibrations • Matched pair - (Standard production calibration where sensor and transmitter is calibrated together) On request1) • Customer-specified calibration up to 10 points On request1) • Customer-witnessed calibration Any of above calibration On request1) 1) Ordering "On request" as dedicated information from the customer on the individual sensors is required. Please fill in the calibration form found on http://intranet.automation.siemens.com/w1/automation-technology-flowmeasurement-18626.htm#content-19336¶1=Flow%20Measurement and send together with the order. (Size dependent restriction on maximum flow rates may apply Siemens FI 01 · 2016 3/61 3 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 1100 F Article No. Accessories Weld-in connection fittings for MAG 1100 F with P gaskets for EHEDG, in stainless steel 1.4404 Only for sensors with PFA liner. 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), P gaskets not included Only for sensors with PFA liner. 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), P gaskets not included DIN 11850 DIN 32676 Adapter Article No. Sensor Adapter DN (mm) Do (mm) Di (mm) DN (mm) 10 15 25 40 34 34 50.5 50.5 10 16 22.6 38 10 15 25 40 A5E02211143 A5E02211144 A5E02211146 A5E02211147 50 65 80 100 64 91 106 119 50 66 81 100 50 65 80 100 A5E02211148 A5E02211151 A5E02211152 A5E02211153 DN (mm) Do (mm) DT (mm) DN (mm) 102) 152) 20 13 19 23 1.5 1.5 1.5 10 153) 15 A5E02054630 A5E02054633 A5E02054634 25 32 40 29 35 41 1.5 1.5 1.5 253) 25 40 A5E02054635 A5E02054637 A5E02054638 50 65 80 100 53 70 85 104 1.5 2.0 2.0 2.0 50 65 80 100 Sensor A5E02054640 A5E02054643 A5E02054644 A5E02054646 ISO 2037 Sensor DN (mm) Do (mm) DT (mm) DN (mm) 12.7 17.2 25 12.7 17.2 25 1.0 1.0 1.6 10 15 253) A5E03727946 A5E03728098 A5E02196073 33 38 40 33.7 38 40 1.6 1.6 1.6 25 403) 40 A5E02196074 A5E02196075 A5E02196076 51 63.5 76.1 51 63.5 76.1 1.6 1.6 1.6 50 65 80 A5E02196077 A5E02196078 A5E02196080 101.6 2.0 100 A5E02196082 Tri-Weld (BS 4825-1) Adapter Sensor DN (mm) Do (mm) DT (mm) DN (mm) 12.7 19.05 25.4 12.7 19.05 25.4 10 15 25 A5E02199113 A5E02199114 A5E02199115 38.1 50.8 63.51) 38.1 50.8 63.5 1.2 1.2 1.6 1.6 1.6 1.6 40 50 65 A5E02199116 A5E02199117 A5E02199118 76.2 101.61) 76.2 101.6 1.6 2.0 80 100 A5E02199119 A5E02199120 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Do: Outer diameter Di: Inner diameter 1) For BS 4825-1 see ISO 2037 2) Not EHEDG approved 3) Default delivery 3/62 ISO 2852 Adapter Adapter 101.6 Di Do D{ Do 3 Accessories Clamp-type connection fittings for MAG 1100 F with P gaskets for EHEDG, in stainless steel 1.4404 Siemens FI 01 · 2016 Sensor DN (mm) Do (mm) Di (mm) DN (mm) 25 50.5 22.6 251) A5E02213581 33.7 38 51 50.5 50.5 64 31.3 35.6 48.6 25 40 50 A5E02213582 A5E02213583 A5E02213584 63.5 76.1 101.6 77.5 91 119 60.3 72.9 97.6 65 80 100 A5E02213585 A5E02213586 A5E02213587 Tri-Clamp (BS 4825-3) Adapter Sensor DN (mm) Do (mm) Di (mm) DN (mm) 12.7 19.05 25.4 38.1 25.4 25.4 50.5 50.5 9.5 15.85 22.2 34.9 10 15 25 40 A5E02213596 A5E02213597 A5E02213598 A5E02213599 50.8 63.5 76.2 101.6 64 77.5 91 119 47.6 60.3 73 97.6 50 65 80 100 A5E02213600 A5E02213601 A5E02213602 A5E02213603 Do: Outer diameter Di: Inner diameter 1) Default delivery © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 1100 F Accessories Threaded type connection fittings for MAG 1100 F with P gaskets for EHEDG, in stainless steel 1.4404 Only for sensors with PFA liner. 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), P gaskets not included Article No. Accessories Threaded type connection fittings for MAG 1100 F with P gaskets for EHEDG, in stainless steel 1.4404 Only for sensors with PFA liner. 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), P gaskets not included Article No. SMS 11451) DIN 11851 Adapter Do (mm) Di (mm) DN (mm) DN (mm) Do (mm) Di (mm) Sensor DN (mm) 10 15 20 28 34 44 10 16 20 10 152) 15 A5E02218293 A5E02218294 A5E02218295 25 38 40 60 22.6 35.6 25 40 A5E02218310 A5E02218312 25 32 40 52 58 65 26 32 38 252) 25 40 A5E02218296 A5E02218297 A5E02218298 51 63.5 76 70 85 98 48.6 60.3 72 50 65 652) A5E02218313 A5E02218314 A5E02218315 50 65 80 100 78 95 110 130 50 66 81 100 50 65 80 100 A5E02218299 A5E02218300 A5E02218301 A5E02218302 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Di Do Sensor DN (mm) Di Do Adapter Do: Outer diameter Di: Inner diameter 1) SMS 1145 standard is not approved by 3A 2) Default delivery Siemens FI 01 · 2016 3/63 3 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 1100 F Article No. Accessories Weld in connection fittings for MAG 1100 F with flat gaskets for 3A, in stainless steel 1.4404 For sensors with ceramic and PFA liner. 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), flat gaskets not included For sensors with ceramic and PFA liner. 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), flat gaskets not included DIN 11850 DIN 32676 Adapter Do (mm) DT (mm) DN (mm) 10 15 20 13 19 23 1.5 1.5 1.5 10 152) 15 FDK:083G2116 FDK:083G2117 FDK:083G2118 25 32 40 29 35 41 1.5 1.5 1.5 252) 25 40 FDK:083G2119 FDK:083G2120 FDK:083G2121 50 65 80 100 53 70 85 104 1.5 2.0 2.0 2.0 50 65 80 100 Sensor DN (mm) Do (mm) DT (mm) DN (mm) 10 15 34 34 10 16 10 15 FDK:083G2186 FDK:083G2187 25 40 50.5 50.5 26 38 25 40 FDK:083G2179 FDK:083G2181 50 65 80 100 64 91 106 119 50 66 81 100 50 65 80 100 FDK:083G2182 FDK:083G2183 FDK:083G2184 FDK:083G2185 DN (mm) Do (mm) DT (mm) DN (mm) 25 50.5 22.6 251) FDK:083G2189 FDK:083G2122 FDK:083G2123 FDK:083G2124 FDK:083G2125 ISO 2037 Do DO DN (mm) Article No. DT Sensor DT Adapter 3 Accessories Clamp-type connection fittings for MAG 1100 F with flat gaskets for 3A, in stainless steel 1.4404 ISO 2852 Adapter Adapter Sensor Sensor DN (mm) Do (mm) DT (mm) DN (mm) 12.7 17.2 25 12.7 17.2 25.6 1.0 1.0 1.6 10 15 252) A5E03720273 FDK:083G2107 FDK:083G2109 33.7 38 51 50.5 50.5 64 31.3 35.6 48.6 25 40 50 FDK:083G2190 FDK:083G2191 FDK:083G2192 33.7 38 40 33.7 38 40 1.6 1.6 1.6 25 402) 40 FDK:083G2100 FDK:083G2111 FDK:083G2101 63.5 76.1 101.6 77.5 91 119 60.3 72.9 97.6 65 80 100 FDK:083G2193 FDK:083G2194 FDK:083G2195 51 63.5 76.1 51 63.5 71.1 1.6 1.6 1.6 50 65 80 FDK:083G2112 FDK:083G2113 FDK:083G2114 Tri-Clamp (BS 4825-3) 101.6 114.3 101.6 118.3 2.0 2.0 100 100 FDK:083G2115 FDK:083G2105 Tri-Weld (BS 4825-1) Adapter Sensor DN (mm) Do (mm) DT (mm) DN (mm) 12.7 19.05 25.4 12.7 19.05 25.4 1.2 1.2 1.6 10 15 25 FDK:083G2276 FDK:083G2277 FDK:083G2279 38 50.8 63.51) 38.1 50.8 63.5 1.6 1.6 1.6 40 50 65 FDK:083G2281 FDK:083G2282 FDK:083G2283 76.2 101.61) 76.2 101.6 1.6 2.0 80 100 FDK:083G2284 FDK:083G2285 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Do: Outer diameter Di: Inner diameter 1) For BS 4825-1 see ISO 2037 2) Default delivery 3/64 Siemens FI 01 · 2016 Adapter Sensor DN (mm) Do (mm) DT (mm) DN (mm) 12.7 19.05 25.4 38.1 25.4 25.4 50.5 50.5 9.5 15.85 22.2 34.9 10 15 25 40 FDK:083G2286 FDK:083G2287 FDK:083G2289 FDK:083G2291 50.8 63.5 76.2 101.6 64 77.5 91 119 47.6 60.3 73 97.6 50 65 80 100 FDK:083G2292 FDK:083G2293 FDK:083G2294 FDK:083G2295 Do: Outer diameter Di: Inner diameter 1) Default delivery © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 1100 F Accessories Threaded type connection fittings for MAG 1100 F with flat gaskets for 3A For sensors with ceramic and PFA liner. 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), flat gaskets not included Article No. Accessories Threaded type connection fittings for MAG 1100 F with flat gaskets for 3A For sensors with ceramic and PFA liner. 2 pcs. fittings 2 pcs. clamps (to join flow sensor and fitting), flat gaskets not included Article No. SMS 11451) DIN 11851 Adapter Do (mm) Di (mm) DN (mm) DN (mm) Do (mm) Di (mm) Sensor DN (mm) 10 15 20 28 34 44 10 16 20 10 152) 15 FDK:083G2156 FDK:083G2157 FDK:083G2158 25 38 40 60 22.6 35.6 25 40 FDK:083G2139 FDK:083G2141 25 32 40 52 58 65 26 32 38 252) 25 40 FDK:083G2159 FDK:083G2160 FDK:083G2161 51 63.5 76 70 85 98 48.6 60.3 72 50 65 652) FDK:083G2142 FDK:083G2143 FDK:083G2144 50 65 80 100 78 95 110 130 50 66 81 100 50 65 80 100 FDK:083G2162 FDK:083G2163 FDK:083G2164 FDK:083G2165 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Di Do: Outer diameter Di: Inner diameter ISO 2853 Adapter Sensor Do (mm) Di (mm) DN (mm) 25 38 51 37 51 64 22.6 35.6 48.6 25 40 50 FDK:083G2149 FDK:083G2151 FDK:083G2152 63.5 76.1 78 91 60.3 72.9 65 80 FDK:083G2153 FDK:083G2154 DN (mm) Do (mm) Di (mm) DN (mm) 101.6 126 97.6 100 1) SMS 1145 standard is not approved by 3A 2) Default delivery Di Do DN (mm) Do Sensor DN (mm) Di Do Adapter BS 4825-4 Adapter Sensor FDK:083G2145 Siemens FI 01 · 2016 3/65 3 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 1100 F Spare parts for MAG 1100 F Article No. Gaskets (delivered in pairs, to be placed between flow sensor and adapter) MAG 1100 F (PFA) - P gaskets 3 Rubber: EPDM (FDA) • DN 10 • DN 15 • DN 25 • DN 40 A5E02055286 A5E02055287 A5E02055290 A5E02055291 • DN 50 • DN 65 • DN 80 • DN 100 A5E02055292 A5E02055293 A5E02055295 A5E02055297 Rubber: FKM/FPM (FDA) • DN 10 • DN 15 • DN 25 • DN 40 A5E00915707 A5E00915764 A5E00915771 A5E00915773 • DN 50 • DN 65 • DN 80 • DN 100 A5E00915775 A5E00915780 A5E00915782 A5E00915784 Rubber: EPDM (FDA) • DN 10 • DN 15 • DN 25 • DN 40 FDK:083G2206 FDK:083G2207 FDK:083G2209 FDK:083G2211 • DN 50 • DN 65 • DN 80 • DN 100 FDK:083G2212 FDK:083G2213 FDK:083G2214 FDK:083G2215 MAG 1100 F (ceramic) - flat gaskets MAG 1100 F (PFA) - flat gaskets Rubber: NBR • DN 10 • DN 15 • DN 25 • DN 40 FDK:083G2216 FDK:083G2217 FDK:083G2219 FDK:083G2221 • DN 50 • DN 65 • DN 80 • DN 100 FDK:083G2222 FDK:083G2223 FDK:083G2224 FDK:083G2225 We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. 3/66 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 1100 F ■ Dimensional drawings Sensor MAG 1100 F compact/remote 131 (5.16) 155 (6.10) 218 (8.58) 208 (8.19) 2 x M25 3 A2 A1 131 (5.16) Di B A B1 M20 (½"NPT) L D L Dimensions in mm (inch) Important note: For compact installation with MAG 6000 I/Ex - Supports the transmitter to avoid tension on the sensor part. Size L A A13) B2) B1 D Di PFA [mm] Weight1) [mm] Di (Al2O3) [mm] DN [mm] [mm] [mm] [mm] [mm] 10 64 161 315 193.7 344.7 64.0 10 10 15 64 161 315 193.7 2.2 344.7 64.0 15 16 25 79 169 323 2.2 207.5 359.0 77.5 25 26 40 94 179 2.7 333 228.0 379.0 91.0 40 38 3.4 50 104 65 131 188 342 247.7 398.7 119.0 50 50 4.2 197.5 351 262.6 413.6 130.0 65 66 80 5.5 156 204 357 281.0 432.0 155.0 80 81 7.0 100 186 217 370 308.0 459.0 183.0 100 100 10.0 Size L A A13) B2) B1 D [inch] [inch] [inch] [inch] [inch] [inch] Di PFA [inch] Weight1) [inch] Di (Al2O3) [inch] 3/8 2.52 6.34 12.40 7.62 13.57 2.52 0.39 0.39 4.8 ½ 2.52 6.34 12.40 7.62 13.57 2.52 0.59 0.63 4.8 1 3.11 6.66 12.72 8.17 14.13 3.05 0.98 1.02 4.9 1½ 3.70 7.05 13.11 8.98 14.92 3.58 1.57 1.50 7.5 2 4.09 7.40 13.47 9.75 15.70 4.68 1.97 1.97 9.2 2½ 5.16 7.78 13.82 10.34 16.28 5.12 2.56 2.60 12.0 3 6.14 8.03 14.06 11.06 17.01 6.10 3.15 3.19 15.0 4 7.32 8.54 14.57 12.13 18.07 7.20 3.94 3.94 22.0 [kg] [lb] 1) With transmitter MAG 5000 or MAG 6000 compact, weight is increased by approximately 0.8 kg (1.8 lb) With MAG 6000 I weight is increased with 5.5 kg ( 12.1 lb) 14.5 mm (0.571“) shorter when the AISI terminal box is used (always Ex version) 3) A is 3 mm (0.12“) shorter than A 2 1 2) Siemens FI 01 · 2016 3/67 © Siemens AG 2016 Flow Measurement SITRANS F M Flow sensor MAG 1100 F Sensor MAG 1100 F compact/separate – build-in length A 3 L Size L1) A DN inch [mm] [inch] [mm] [inch] 10 3/8 99 3.90 146 5.75 15 ½ 99 3.90 146 5.75 25 1 113 4.45 161 6.34 40 1½ 126 4.96 176 6.93 50 2 154 6.06 186 7.32 65 2½ 165 6.50 223 8.78 80 3 200 7.87 258 10.16 100 4 225 8.86 288 11.34 1) The total build-in length “L” is independent of the adapter type selected. 3/68 Siemens FI 01 · 2016