SITRANS FM MAG 1100 Catalog Specification Sheet

© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 1100 and MAG 1100 HT
■ Overview
■ Mode of operation
The flow measuring principle is based on Faraday’s law of electromagnetic induction according to which the sensor converts
the flow into an electrical voltage proportional to the velocity of
the flow.
■ Integration
The complete flowmeter consists of a flow sensor and an associated transmitter SITRANS F M MAG 5000, 6000 or 6000 I. The
flexible communication concept USM II simplifies integration
and update to a variety of fieldbus systems such as HART,
FOUNDATION Fieldbus H1, DeviceNet, PROFIBUS DP and PA,
Modbus RTU/RS 485.
3
The SITRANS F M MAG 1100 is an electromagnetic flow sensor
in a compact wafer design designed for flow applications in the
process industry.
■ Benefits
• Sensor sizes: DN 2 to 100 (1/12” to 4”)
• Compact wafer design meets EN 1092, DIN and ANSI flange
standards
• Corrosion resistant AISI 316 stainless steel sensor housing
• Highly resistant liner and electrodes fitting most extreme process media
• Temperature rating up to 200 °C (392 °F)
• Hose proof IP67/NEMA 4X enclosure rating
• Designed that patented in-situ verification can be conducted.
Using SENSORPROM fingerprints.
■ Application
The main applications of the SITRANS F M electromagnetic flow
sensors can be found in the following fields:
• Process industry
• Chemical industry
• Pharmaceutical industry
• Water treatment like e.g. chemical dosing
■ Design
•
•
•
•
•
Compact or remote mounting possible
Easy "plug & play" field changeability of transmitter
Simple on site upgrade to IP68/NEMA 6P terminal box
Ex ATEX 2G D version
FM Class I, Div 2
3/50
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 1100 and MAG 1100 HT
■ Technical specifications
Version
MAG 1100
MAG 1100 HT (High temperature)
Measuring principle
Electromagnetic induction
Electromagnetic induction
Excitation frequency
(Mains supply: 50 Hz/60 Hz)
DN 2 ... 65 (1/12“ … 2½”): 12.5 Hz/15 Hz
DN 80, 100 (3”, 4”): 6.25 Hz/7.5 Hz
DN 15 ... 50 (½“ … 2”): 12.5 Hz/15 Hz
DN 80, 100 (3”, 4”): 6.25 Hz/7.5 Hz
• MAG 1100 (Ceramic)
DN 2 … DN 100 (1/12" … 4")
DN 15 … DN 100 (½” … 4")
• MAG 1100 (PFA)
DN 10 … DN 100 (3/8" … 4")
Mating flanges
EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300 EN 1092-1 (DIN 2501), ANSI B 16.5 class 150 and 300
or equivalent
or equivalent
Option:
DN 2 ... 10 (1/12” ... 3/8”):
G½” / NPT ½” pipe connection adapters
Process connection
Nominal size
Rated operating conditions
Ambient conditions
Ambient temperature1)
• Standard sensor
-40 … +100 °C (-40 … +212 °F)
-40 … +100 °C (-40 … +212 °F)
• Ex sensor
-20 … +60 °C (-4 … +140 °F)
-20 … +60 °C (-4 … +140 °F)
• Compact transmitter
MAG 5000/60002)
-20 … +60 °C (-4 … +140 °F)
• Compact transmitter MAG 6000 I -20 … +60 °C (-4 … +140 °F)
• Compact transmitter
MAG 6000 I Ex
-20 … +60 °C (-4 … 140 °F)
Temperature of medium
• MAG 1100 (Ceramic)
-20 … +150 °C (-4 … +302 °F)
-20 … +200 °C (-4 … +392 °F)
• MAG 1100 Ex (Ceramic)
-20 … +150 °C (-4 … +302 °F)
-20 … +180 °C (-4 … +356 °F)
• MAG 1100 (PFA)
-30 … +130 °C (-22 … +266 °F)
Suitable for steam sterilization at 150 °C (302 °F)
Temperature shock
• MAG 1100 (Ceramic)
- Duration  1 min, followed by
10 min rest
• MAG 1100 (PFA)
• DN 2, 3 (1/12”, 1/8”) No limitations
• DN 6, 10, 15, 25: Max. T  80 °C/min
(¼”, 3/8”, ½”, 1”: Max. T  144 °F/min)
• DN 40, 50, 65: Max. T  70 °C/min
(1½”, 2”, 2½”: Max. T  126 °F/min)
• DN 80, 100: Max. T  60 °C/min
(3”, 4”: Max. T  108 °F/min)
• DN 15, 25: Max. T  80 °C/min
(½”, 1”: Max. T  144 °F/min)
• DN 40, 50: Max. T  70 °C/min
(1½”, 2”: Max. T  126 °F/min)
• DN 80, 100: Max. T  60 °C/min
(3”, 4”: Max. T  108 °F/min)
Max.  100 °C (212 °F) momentarily
Operating pressure
• MAG 1100 (Ceramic)
• DN 2 ... 65: 40 bar (1/12” … 2½”: 580 psi)
• DN 80: 37.5 bar (3”: 540 psi)
• DN 100: 30 bar (4”: 435 psi)
Vacuum: 1 x 10-6 barabs (1.5 x 10-5 psiabs)
• DN 15 ... 50: 40 bar (½” … 2”: 580 psi)
• DN 80: 37.5 bar (3”: 540 psi)
• DN 100: 30 bar (4”: 435 psi)
Vacuum: 1 x 10-6 barabs (1.5 x 10-5 psiabs)
• MAG 1100 (PFA)
20 bar (290 psi)
Vacuum: 0.02 barabs (0.3 psiabs)
DN 80 ... DN 100: CO2 pressure max. 7 bar (101.5 psi)
Mechanical load (vibration)
• 18 ... 1000 Hz random in x, y, z, directions for 2 hours • 18 ... 1000 Hz random in x, y z, directions for 2 hours
according to EN 60068-2-36
according to EN 60068-2-36
• Sensor: 3.17 g RMS
• Sensor: 3.17 g RMS
• Sensor with compact MAG 5000/ 6000 mounted transmitter: 3.17 g RMS
• Sensor with compact MAG 6000 I/ 6000 I Ex mounted
transmitter: 1.14 g RMS
• For compact installation with the MAG 6000 I, transmitter to be supported to avoid tension on sensor part.
Enclosure rating (standard)
IP67 to EN 60529 (NEMA 4X), 1 mH2O for 30 min
IP67 to EN 60529 (NEMA 4X), 1 mH2O for 30 min
EMC
2014/30/EU
2014/30/EU
Siemens FI 01 · 2016
3/51
3
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 1100 and MAG 1100 HT
Version
MAG 1100
MAG 1100 HT (High temperature)
Design
Weight
See Dimensional drawings
See Dimensional drawings
• Enclosure
- MAG 1100
Stainless steel AISI 316L/1.4404
Stainless steel AISI 316L/1.4404
• Terminal box
- Standard
- Option
Fibre glass reinforced polyamide (not for Ex)
Stainless steel AISI 316/1.4436
Stainless steel AISI 316/1.4436
Stainless steel AISI 304/1.4301,
Number and size to EN 1092-1:2001
Stainless steel AISI 304/1.4301,
Number and size to EN 1092-1:2001
Material
3
• Fixing studs
• Gaskets
- Standard
- Option
EPDM (max. 150 °C, PN 40 (max. 302 °F, 600 psi))
Graphite (max. 200 °C, PN 40 (max. 392 °F, 600 psi))
• Graphite (max. 200 °C, PN 40 (max. 392 °F, 600 psi))
• PTFE (max. 130 °C, PN 25 (max. 266 °F, 300 psi))
• Pipe connection adapters:
• Stainless steel, AISI 316/1.4436
DN 2, 3, 6 and 10 (1/12“, 1/8“, ¼” • Hastelloy C22/2.4602
and 3/8”)
• PVDF
Liner
• MAG 1100 (Ceramic)
• DN 2, 3 (1/12“, 1/8“): Zirconium oxide (ZrO2)
(ceramic)
• DN 6 ... 100 (¼“ ... 4“): Aluminum oxide Al2O3
• MAG 1100 (PFA)
Reinforced PFA (not for Ex)
DN 15 ... 100 (½“ ... 4“): Aluminum oxide Al2O3
Electrodes
• MAG 1100 (Ceramic)
• DN10 ... 100 (3/8" ... 4") : Platinum with gold / Titanium Platinum with gold / Titanium brazing alloy
brazing alloy
• DN 2 ... 6 (1/12“ ... ¼”): Platinum
• MAG 1100 (PFA)
• DN 10 ... 15 (3/8" ... ½"): Hastelloy C276/2.4819
• DN 25 ... 100 (1" ... 4"): Hastelloy C22/2.4602
Cable entries
• Remote installation 2 x M20 or 2 x ½" NPT
• Compact installation
- MAG 5000/MAG 6000: 4 x M20 or 4 x ½” NPT
- MAG 6000 I: 2 x M25 (for supply/output)
- MAG 6000 I Ex: 2 x M25 (for supply/output)
Remote installation 2 x M20 or 2 x ½“ NPT
• Standard production calibration
(default), calibration report
shipped with sensor
Zero-point, 2 x 25 %, 2 x 90 %
Zero-point, 2 x 25 %, 2 x 90 %
• Special calibration
5-point calibration: 20 %, 40 %, 60 %, 80 %, 100 % of
factory Qmax
10-point calibration: ascending and descending at
20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax
Matched-pair calibration: default, 5-point or 10-point
Conforms to
PED – 2014/68/EU3) (Fluid group: Liquid of fluid
group 1
PED – 2014/68/EU3)
Material certificate EN 10204-3.1
Available when ordering together with meter4)
Available when ordering together with meter4)
- Ex sensor or Compact with
MAG 6000 I Ex
ATEX 2G D sensor Ex de ia IIB T3 - T6
ATEX 2G D sensor Ex de ia IIB T3 - T6
- Sensor with/without
MAG 5000/6000 /6000 I
FM Class I, Div 2
FM Class I, Div 2
Certificates and approvals
Calibration
Ex approvals
• MAG 1100 (Ceramic)
• MAG 1100 (PFA)
- Sensor with/without
MAG 5000/6000/6000 I
• Custody transfer approval
(MAG 5000/6000 CT)2)
FM Class I, Div 2
• Cold water pattern approval PTB (Germany)
• Other media than water pattern approval- OIML R 117
(Ceramic liner) (Denmark)
1)
Conditions are also dependent on liner characteristics
2)
With compact transmitter MAG 5000 CT/6000 CT -20 ... +50 °C (-4 ... +122 °F)
3) For further information on the PED standard and requirements, see page 9/6.
4) Has to be ordered with the meter. It is not possible to order the certificate afterwards.
For technical specification for transmitter - see transmitter pages.
3/52
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 1100 and MAG 1100 HT
Selection and Ordering data
Article No.
Selection and Ordering data
Sensor SITRANS F M MAG 1100
EPDM gaskets included
7 ME 6 1 1 0 -
Additional information
7 7 0A 7 00 - 7 7 7 7
Please add “-Z“ to Article No. and specify Order
code(s) and plain text.
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Order code
Special calibration
Diameter
• 5-point calibration1)
D01
DN 2 (1/12“)
 1D
• 10-point calibration2)
D06
D11
 1H
• Default (2 x 25 % and 2 x 90 %) matched-pair
calibration
1)
• 5-point, matched-pair calibration1)
D15
 1M
• 10-point, matched-pair calibration2)
D18
DN 10 (3/8“)
DN 15 (½“)
 1R
 1V
Customer-specific converter setup
Y20
Y17
DN 25 (1“)
DN 40 (1½“)
DN 50 (2“)
 2D
 2R
 2Y
Tag name plate, stainless steel fixed with SS wire
(add plain text)
Tag name plate, plastic (self adhesive)
Y18
Material certificate according to EN 10204-3.1
C12
Factory certificate according to EN 10204-2.2
C14
Factory certificate according to EN 10204-2.1
C15
DN 3 (1/8“)
DN 6 (¼“)
DN 65 (2½“)
DN 80 (3“)
DN 100 (4“)
1)
1)
 3F
 3M
 3T
Region specific approvals and certificates
Liner material
• KCC label
W28
Terminal blocks
• Factory mounted terminal blocks
N02
Electrode material
Sensor cables wired (specify cable Article No.)
Y40
Hastelloy C (only with PFA liner)
Platinum (only with ceramic liner)
Sensor for remote transmitter's junction box potted to
IP68 with wired cable (specify cable Article No.)
(not for Ex sensors)
Y41
Other postproduction requirements (add desired text)
Y99
PFA - DN 10 ... 100 (3/8“ ... 4“) (not for Ex)
Ceramic
Transmitter
Standard sensor for remote transmitter
(order transmitter separately)
Ex sensor for remote transmitter
(order transmitter separately)
MAG 6000 I, Aluminum 18 ... 90 V DC,
115 ... 230 V AC
MAG 6000 I, Aluminum 18 ... 30 V DC, Ex
MAG 6000 I, Aluminum 115 ... 230 V AC, Ex
MAG 6000 Polyamide, 11 ... 30 V DC/
11 … 24 V AC
MAG 6000, Polyamide, 115 ... 230 V AC
MAG 5000, Polyamide, 11 ... 30 V DC/
11 ... 24 V AC
MAG 5000, Polyamide, 115 ... 230 V AC







1
2
1
2
A
Additional calibrations
B
• Matched pair - (Standard production calibration
where sensor and transmitter is calibrated together)
On request3)
C
• Customer-specified calibration up to 10 points
On request3)
• Customer-witnessed calibration
Any of above calibration
On request3)
D
E
H

J
K

L
Communication
No communication, add-on possible
HART
PROFIBUS PA Profile 3
(only MAG 6000/MAG 6000 I)
PROFIBUS DP Profile 3 (not for Ex)
(only MAG 6000/MAG 6000 I)
Modbus RTU/RS 485 (not for Ex)
(only MAG 6000/MAG 6000 I)
FOUNDATION Fieldbus H1
(only MAG 6000/MAG 6000 I)
3
1)
20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax
2)
Ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory
Qmax
3)
Ordering On request as dedicated information from the customer on the
individual sensors is required. Please fill in the calibration form found on
http://www.automation.siemens.com/mcms/automation/en/sensor-systems/process-instrumentation/Pages/Default.aspx and send together with
the order. (Size dependent restriction on maximum flow rates may apply
Operating instructions for SITRANS F M MAG 1100



A
B
F

G
This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature.

E
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
J
Accessories
Cable glands/terminal box
Metric: Polyamide terminal box or 6000 I compact 
½" NPT: Polyamide terminal box or 6000 I compact 
Metric: SS terminal box (mandatory for stainless
steel MAG 6000 transmitter)
½" NPT: SS terminal box (mandatory for stainless
steel MAG 6000 transmitter)
Description
Article No.
• English
A5E02435647
,
Description
1
2
3
Potting kit for terminal box
of flow sensors for
IP68/NEMA 6P
Article No.
 FDK:085U0220
4
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
1) Quick ship only in combination with Ceramic liner
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Siemens FI 01 · 2016
3/53
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 1100 and MAG 1100 HT
Selection and Ordering data
Operating instructions for SITRANS F M MAG 1100
Article No.
Description
Article No.
7 ME 6 1 2 0 -
• English
A5E02435647
7 7 0A 2 00 - 2 7 A 7
This device is shipped with a Quick Start guide and a CD containing further SITRANS F literature.
Sensor SITRANS F M
MAG 1100 HT High Temperature
Ceramic liner, Platinum electrode,
Graphite gaskets included
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
3
Diameter
DN 15 (½“)
DN 25 (1“)
DN 40 (1½“)
1V
2D
2R
DN 50 (2“)
DN 80 (3“)
DN 100 (4“)
2Y
3M
3T
MAG 5000/6000 transmitters and sensors are packed in separate boxes, the final assembly takes place during installation at
the customer's place. MAG 6000 I/MAG 6000 I Ex ATEX 2G D
transmitters and sensors are delivered compact mounted from
factory. Communication module will be premounted in the transmitter.
Please use online Product selector to get latest updates.
Transmitter
Standard sensor for remote transmitter (order transmitter separately)
Ex sensor for remote transmitter (order transmitter
separately)
Accessories
B
,
Description
Cable glands/terminal box
Metric: SS terminal box
½" NPT: SS terminal box
Selection and Ordering data
Product selector link:
www.pia-portal.automation.siemens.com
A
3
4
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Please add “-Z“ to Article No. and specify Order
code(s) and plain text.
Special calibration
• 5-point calibration1)
D01
• 10-point calibration2)
D06
• Default (2 x 25 % and 2 x 90 %) matched-pair calibration
D11
• 5-point, matched-pair calibration1)
D15
• 10-point, matched-pair calibration2)
D18
Customer-specific converter setup
Y20
Tag name plate, stainless steel fixed with SS wire
(add plain text)
Y17
Tag name plate, plastic (self adhesive)
Y18
Material certificate according to EN 10204-3.1
C12
Factory certificate according to EN 10204-2.2
C14
Factory certificate according to EN 10204-2.1
C15
Region specific approvals and certificates
• KCC label
W28
Terminal blocks
• Factory mounted terminal blocks
N02
Sensor cables wired (specify cable Article No.)
Y40
Sensor for remote transmitter's junction box potted to
IP68 with wired cable (specify cable Article No.) (not
for Ex sensors)
Y41
Other postproduction requirements (add desired text)
Y99
Additional calibrations
• Matched pair - (Standard production calibration
where sensor and transmitter is calibrated together)
On request3)
• Customer-specified calibration up to 10 points
On request3)
• Customer-witnessed calibration
Any of above calibration
On request3)
1)
20 %, 40 %, 60 %, 80 %, 100 % of factory Qmax
2)
Ascending and descending at 20 %, 40 %, 60 %, 80 %, 100 % of factory
Qmax
3)
Ordering On request as dedicated information from the customer on the
individual sensors is required.
Siemens FI 01 · 2016
Potting kit for terminal box of  FDK:085U0220
flow sensors for IP68/
NEMA 6P
Order code
Additional information
3/54
Article No.
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 1100 and MAG 1100 HT
Accessories
for MAG 1100 sensor
Article No.
Grounding ring SS
Material: AISI 316/1.4436;
each set includes: 1 grounding ring1), 3 PTFE
gaskets, 1 grounding wire, 1 M6 screw
Pipe connection ½" external thread
For DN 2 ... 10 (1/12“ ... 3/8“) sensor,
material: SS 316
2 pipe connections, 2 EPDM gaskets,
12 pcs M4 x 12 screws
• ½" G, ISO 7-1 tappered thread, SS 316
• ½" NPT thread, SS 316
 FDK:083G0080
 FDK:083G4330
For DN 2 ... 10 (1/12“ ... 3/8“) sensor,
material: Hastelloy C
2 pipe connections, 2 PTFE gaskets,
12 pcs M4 x 14 screws
• ½" G, ISO 7-1 tappered thread
• ½" NPT thread
 FDK:083G4332
 FDK:083G4331
For DN 2…10 (1/12”…3/8”) sensor
2 PVDF pipe connections (Max. 70 ºC,
PN 8 bar/max 158 ºF, 116 PSI), 1 grounding
ring1), 1 grounding wire, 3 PTFE gaskets,
2 space rings, 6 pcs. M4 x 12 and 6 pcs.
M4 x 20 screws
• ½”G, ISO 7-1 tapered thread PVDF incl.
grounding ring Hastelloy C22/2.4602
• ½” NPT thread PVDF incl. grounding ring
Hastelloy C22/2.4602
Article No.
Accessories
for MAG 1100 sensor
A5E01018395
 FDK:083G0686
 FDK:083G0687
 FDK:083G0689
• DN 2 ... 10 (1/12“ ... 3/8“)
• DN 15 (½“)
• DN 25 (1“)
• DN 40 (1½“)
• DN 50 (2“)
• DN 65 (2½“)
FDK:083G0691
FDK:083G0692
FDK:083G0693
• DN 80 (3“)
• DN 100 (4“)
FDK:083G0694
FDK:083G0695
Grounding ring (Hastelloy C)
Material: Hastelloy C22/2.4602;
each set includes:
1 grounding ring1), 3 PTFE gaskets,
1 grounding wire, 1 M6 screw
A5E01018400
EPDM gaskets
Material: EPDM; each set includes:
2 EPDM gaskets, 1 grounding wire, 1 M6
screw, 1 nut, 1 washer, 1 bolt grounding plate
• DN 2 ... 10 (1/12“ ... 3/8“)
 FDK:083G3116
• DN 15 (½“)
 FDK:083G3117
• DN 25 (1“)
 FDK:083G3119
• DN 40 (1½“)
• DN 50 (2“)
• DN 65 (2½“)
 FDK:083G3121
 FDK:083G3122
 FDK:083G3123
• DN 80 (3“)
• DN 100 (4“)
 FDK:083G3124
 FDK:083G3125
PTFE gaskets
Material: PTFE; each set includes:
2 gaskets, 2 grounding wires, 3 M6 screws
(DN 2 ... DN 10: 12 pcs M4 x 14)
• DN 2 ... 10 (1/12“ ... 3/8“)
• DN 15 (½“)
• DN 25 (1“)
 FDK:083G0156
 FDK:083G0157
 FDK:083G0159
• DN 40 (1½“)
• DN 50 (2“)
• DN 65 (2½“)
 FDK:083G0161
 FDK:083G0162
 FDK:083G0163
• DN 80 (3“)
• DN 100 (4“)
 FDK:083G0164
 FDK:083G0165
Graphite gaskets
Material: Graphite; conductive,
each set includes: 2 gaskets (conductive (can
also be used as grounding ring))
• DN 2 ... 10 (1/12“ ... 3/8“)
 FDK:083G0116
• DN 15 (½“)
 FDK:083G0117
• DN 25 (1“)
 FDK:083G0119
• DN 2 ... 10 (1/12“ ... 3/8“)
• DN 15 (½“)
• DN 25 (1“)
 FDK:083G3256
 FDK:083G3257
 FDK:083G3259
• DN 40 (1½“)
• DN 50 (2“)
• DN 65 (2½“)
 FDK:083G3261
 FDK:083G3262
FDK:083G3263
• DN 80 (3“)
• DN 100 (4“)
FDK:083G3264
FDK:083G3265
Grounding ring (Tantalum)
Material: Tantalum; each set includes:
1 grounding ring1), 3 PTFE gaskets,
1 grounding wire, 1 M6 screw
• DN 2 ... 10 (1/12“ ... 3/8“)
A5E01181599
• DN 15 (½“)
• DN 25 (1“)
A5E01181606
A5E01181610
• DN 40 (1½“)
• DN 50 (2“)
• DN 65 (2½“)
A5E01181613
A5E01181615
A5E01181616
A5E01181619
A5E01181622
• DN 40 (1½“)
• DN 50 (2“)
• DN 65 (2½“)
 FDK:083G0121
 FDK:083G0122
 FDK:083G0123
• DN 80 (3“)
• DN 100 (4“)
• DN 80 (3“)
• DN 100 (4“)
 FDK:083G0124
 FDK:083G0125
Studs and nuts
for DN 100 PN 25/40, 8 M20 studs,
16 M20 nuts
Material: AISI 304/1.4305
• DN 100 (4“)
1)
 FDK:083G0226
Thickness of grounding ring is 2 mm (0.08 inch)
 We can offer shorter delivery times for configurations designated with
the Quick Ship Symbol . For details see page 9/5 in the appendix.
Siemens FI 01 · 2016
3/55
3
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 1100 and MAG 1100 HT
■ Dimensional drawings
Sensor MAG 1100, compact/remote
131 (5.16)
155 (6.10)
218 (8.58)
208 (8.19)
6,75$16)00$*)/20$*,1'8675<
&RGHQR)'.)
6HULDOQR
)LUPZDUHYHUVLRQ
6XSSO\
(QFORVXUH 7HPS$PE ,,*
6,5$$7(;;
(([GH>LD@LD,,%7
2 x M25
,6,17(5)$&(
6HHPDQXDO
3
6LHPHQV)ORZ,QVWUXPHQWV$6
0DGHLQ'HQPDUN
A1
M20
(½" NPT/
PG 13.5)
131 (5.16)
A2
B1
A
DP
Di
DG
B
L
D
L
Dimensions in mm (inch)
Important note: For compact installation with MAG 6000 I/Ex - transmitter to be supported to avoid tension on the sensor part
Size
DN
A1)
[mm]
B1)
[mm]
A1/A23)
[mm]
B1
[mm]
D
[mm]
Di
[mm]
2
161
186
315
340
48.7
3
161
186
315
340
48.7
6
161
186
315
340
10
161
186
315
15
161
186
25
169
40
DP
[mm]
DG
[mm]
Weight2)
[kg]
2
17.3
34
2.2
3
17.3
34
2.2
48.7
6
17.3
34
2.2
340
48.7
10
10
13.6
34
2.2
315
340
48.7
15
16
17.3
40
2.2
201
323
354
63.5
25
26
28.5
56
2.7
179
221
333
375
84.0
40
38
43.4
75
3.4
50
188
239
342
393
101.6
50
50
54.5
90
4.2
65
198
258
351
412
120.9
65
66
68.0
112
5.5
80
204
270
357
424
133.0
80
81
82.5
124
7.0
100
217
296
370
450
159.0
100
100
107.1
150
10.0
Size
[inch]
A1)
[inch]
B1)
[inch]
A1/A23)
[inch]
B1
[inch]
D
[inch]
Di
[inch]
Di (PFA)
[inch]
DP
[inch]
DG
[inch]
Weight2)
[lb]
1/12
6.34
7.33
12.40
13.39
1.92
0.08
0.68
1.34
4.8
1/8
6.34
7.33
12.40
13.39
1.92
0.12
0.68
1.34
4.8
¼
6.34
7.33
12.40
13.39
1.92
0.24
0.68
1.34
4.8
3/8
6.34
7.33
12.40
13.39
1.92
0.39
0.39
0.53
1.34
4.8
½
6.34
7.33
12.40
13.39
1.92
0.59
0.63
0.68
1.57
4.8
1
6.66
7.92
12.72
13.94
2.50
0.98
1.02
1.12
2.20
4.9
1½
7.05
8.70
13.11
14.76
3.31
1.57
1.50
1.71
2.95
7.5
2
7.40
9.41
13.47
15.47
4.00
1.97
1.97
2.15
3.54
9.2
2½
7.80
10.16
13.82
16.22
4.76
2.56
2.60
2.68
4.41
12
3
8.03
10.63
14.06
16.70
5.24
3.15
3.19
3.25
4.88
15
4
8.54
11.65
14.57
17.72
6.26
3.94
3.94
4.22
5.91
22
1)
Di (PFA)
[mm]
14.5 mm/0.571" shorter when the AISI terminal box is used (Ex or high temperature 200 °C (392 °F) version)
2)
With transmitter MAG 5000 or MAG 6000 installed, weight is increased by approximately 0.8 kg (1.8 lb).
With MAG 6000 I weight is increased with 5.5 kg (12.1 lb).
3)
A2 is 3 mm (0.12“) shorter than A1
3/56
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F M
Flow sensor MAG 1100 and MAG 1100 HT
The total build-in length “L” [mm]/[inch] before assembling depends on the gasket selected
Size
EPDM
PTFE (Teflon)
Without gasket
Grounding ring
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
1/12 ... 3/8 64
2.52
66
2.60
70
2.75
64
2.52
77
3.03
15
½
65
2.56
66
2.60
70
2.75
64
2.52
77
3.03
25
1
80
3.15
81
3.19
85
3.35
79
3.10
92
3.62
40
1½
95
3.74
96
3.78
100
3.94
94
3.70
107
4.21
50
2
105
4.13
106
4.17
110
4.33
104
4.05
117
4.61
65
2½
130
5.12
131
5.15
135
5.31
129
5.05
142
5.60
80
3
155
6.10
156
6.14
160
6.30
154
6.00
167
6.57
100
4
185
7.28
186
7.31
190
7.48
184
7.20
197
7.76
DN
inch
2 ... 101)
1)
[mm]
Graphite
Mounting between two flanges
Sensor MAG 1100 DN 2 ... 10 (1/12“ ... 3/8“) with adapters
1/2" thread
6 x M4
20 (0.79)
35 (1.38)
52 (2.05)
L
The MAG 1100 DN 2, 3, 6 and 10 (1/12“, 1/8“, ¼” and 3/8”) are prepared for assembly with the ½” pipe connections. Dimensions in mm (inch)
The length “L“ varies dependent on the gasket choice.
Stainless steel and Hastelloy pipe connections
PVDF pipe connections
Without gasket
EPDM
Graphite
PTFE
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
[mm]
[inch]
PTFE
[mm]
[inch]
150
5.9
150
5.9
152
6.0
156
6.1
133
5.2
Important note:
For compact installation with the MAG 6000 I, transmitter to be supported to avoid tension on sensor part.
Siemens FI 01 · 2016
3/57
3