Resource Center 30.5mm pilot devices Answers for industry. Siemens 30.5mm Pilot Device Resource Center Table of Contents General Information Technical Specifications Pushbuttons Non-Illuminated – Illuminated 1 2 Selector Switches; 4-Position/Specialty Non-Illuminated – Specialty 3 Push-Pull Operators; 2-Position Maintained Non-Illuminated, Illuminated Pilot Lights Plastic – Glass 9 23, 25 Non-Illuminated – Illuminated Accessories Cam and Contact Block Selection Selector Switches; 3-Position Non-Illuminated – Illuminated – Keyed 17, 21 7 Push-Pull Units; 3-Position Push-Maintained, Pull Momentary Selector Switches; 2-Position Non-Illuminated – Illuminated – Keyed 17, 19 5 Push-Pull Units; 3-Position Momentary Non-Illuminated, Illuminated Twist to Release Non-Illuminated – Illuminated 15 27 28 11, 13 Siemens 30.5mm Pilot Devices General Information Features n Octagonal Mounting Nuts n Meets Type 1, 3, 3R, 4, 4X, 12, 13 and Automotive Standards n Heavy Duty Rated NEMA A600/P600 Contacts n Positive Indexing Selectors n Bifurcated Movable Contacts n Attractive Chrome Plating or Black Matte Finish n Boots Not Required for Type 4 n UL Listed File # E22655 n CSA Certified File # LR6535 n Touchsafe Terminals Application Siemens pilot devices and accessories are designed to provide long, trouble free service in the most demanding of industrial applications. These controls are water, oil, and dust tight and meet NEMA Type 1, 3, 3R, 4, 4X, 12, and 13 specifications. Rugged Industrial control operators are of durable one piece castings. Heavy duty plastic buttons resist oils and corrosion. Silver contacts carry heavy duty ratings while standard gold flashing on contacts allows for use in low current applications. Flexible Accessories modify standard pushbuttons, selector switches, and pilot lights. Building block construction of contact blocks makes it possible for many circuitry combinations. Industrial Appearance Pilot controls add luster to panels. Chrome plating covers exposed metal parts. The black matte finish of Black Max pilot device operators allows for an alternative look to finished panels while still offering corrosion resistance and superior ingress protection. Pushbutton Operators The pushbutton operator base consists of a durable, one piece casting. The base is equipped with a heavy duty actuator with a stainless steel spring, a neoprene actuator sealing ring to prevent water, oil, and dust from penetrating to the contact blocks, a neoprene gasket to seal operator mounting hole, and a chrome plated locknut. Mushroom Head Pushbutton Operators Operator base construction is identical to the pushbutton operator base. The actuator is molded of high impact material for either a 1 ⁵⁄₈ inch or 2 ¹⁄₂ inch diameter molded head. Contact Blocks Contact blocks have double-break bifurcated silver contacts, with gold flashing as standard, which improves contact fidelity. Contact blocks are heavy duty rated NEMA A600/P600 and suitable for applications down to 5V/1MA solid state outputs. Molded bodies and pushers resist arcing and tracking. All units have stainless steel springs that resist corrosion and provide strong contact pressure. Captive mounting screws speed panel assembly. Push-Pull Operators Push-pull operators combine two or three functions in one unit. The maintained operator has two positions, typically pull to start, push to stop. The momentary operator with three positions provides spring return from both pull and push positions. A three-position operator with push maintained and pull momentary is available. Push-pull operators are available in illuminated or non-illuminated versions. Two-button Maintained Operator Two-button maintained operator pushbuttons consist of two Pushbuttons and a latching assembly. When actuated the button remains depressed and is freed only by the release operator to which it is linked. The button assembly adjusts for mounting from a 1¹³⁄₁₆ inch to a 2 ⁵⁄₈ inch center. Transformer Type Pilot Lights Transformer type pilot lights are available with a 120, 240, 277, 480, or 600 Volt primary (50/60 Hertz) and a separate secondary winding which supplies reduced voltage to a miniature bayonet base 6 Volt lamp. These units are suitable for applications where vibration is present and long bulb life is desirable. Full Voltage Type Pilot Lights Full voltage pilot lights are available for 6, 12, 24, 120, 277V, and 240 Volt AC and DC applications. The 240 volt pilot light is supplied with a 120 volt lamp and a voltage dropping resistor. LED Type Pilot Lights and LED Module The integrated LED modules are a single unit combining all the features of a LED bulb and lighting module into one. These will have extended life and are the most resistant to vibration. LEDs (light emitting diodes) can be used in pilot lights instead of incandescent bulbs because of their extremely long life, resistance to vibration, and ambient sensitivity. Selector Operators Selector operators have positive action indexing. Operators are available with either a short or long lever. The molded black lever is designed to accept a color insert. A white insert is provided as standard; however, eight alternative lever insert colors are available. Each operator is equipped with a cam to actuate plungers of contact blocks assembled behind the operator. Two, three, and four position operators are available with seven different cams. 1 Siemens 30.5mm Pilot Devices Technical Specifications Standards Utilization Degree of Protection UL Listed File # E22655 Category NEMA 52B, 52P-, 52S-, 52M- Operators CSA Certified File # LR6535 A600/P600 NEMA: 1, 3, 3R, 4, 4X, 12 and 13 IEC 529; IP10, IP11, IP14, IP52, IP54, and IP56 Rated Operational Current NEMA A600 - 10 Continuous Amps Voltage AC Make Amps Break Amps 120V 60 6 240V 30 3 480V 15 1.5 600V 12 1.2 Total VA 7200 720 Contact Blocks Pilot Light Push-to-Test Illuminated Push-Pull Illuminated Selector Switch NEMA P600 - Rating Codes for DC Control Circuit Application Thermal Continuous Test Current Amps 5.0 Maximum Make or Break; Current / Amps 125V 1.10 250V 0.55 301-600V 0.20 Maximum Make or Break Volt amperes at 300V or Less 138 52BAK, -BAJ, -BAH, -BAU, -BJK 600VAC Maximum, Heavy Duty 52BAR 200VAC .25 Amp, 10 Watt Maximum 200VDC .50 Amp, 10 Watt Maximum Contact blocks are suitable for applications down to 5V/1MA low voltage applications as found in PLCs. 52BAR are Class 1; Division 2 Compliant Full Voltage 52PL4 -B (6-8V), -C (12V), -D (24V), -E (120V) 120V AC/DC Maximum LED Module 52PL5 -L (24V), -M (120V) -N (240V) 240V AC Maximum Transformer Type 52BL452BL5 -G (120V), -H (240V), -J (480V), K (600V) 600V AC Maximum, 50/60 Hz Full Voltage 52PT6 -B (6-8V), -C (12V), -D (24V), -E (120V) 24V AC/DC Maximum LED Module 52BP6 -L (24V), -M (120V), -N (240V) 240V AC Maximum Transformer -G (120V), -H (240V), -J (480V), -K (600V) 600VAC Maximum, 50/60 Hz Full Voltage LED Module 52PP2(3,7) -B (6-8V), -C (12V), -D (24V), -E (120V) 24V AC/DC Maximum -L (24V), -M (120V), - N (240V) 240V AC Maximum Transformer 52BP2(3,7) -G (120V), -H (240V), -J (480V), -K (600V) 600VAC Maximum, 50/60 Hz Full Voltage Transformer 52SA7 52SA7 -AD,-BD,-CD -AG, (120V), -BG (120V), -CG (120V), -BH (240V), -CH (240V) 2200V for one minute 24V AC/DC Maximum 240VAC Maximum, 50/60 Hz Dielectric Strength Mechanical Design Life Cycles Vibration Frequency 5 - 60Hz.; Disp. .030 inches, sweep 5 minutes for a duration of 30 minutes on each axis. Not to exceed 5.5 G’s for maximum of 1 minute. Pushbuttons Momentary, Non-illuminated 5,000,000 Operating Cycles Momentary, Illuminated 300,000 Operating Cycles Push-Pull Maintained 300,000 Operating Cycles Momentary 2,000,000 Operating Cycles Twist-to-Release 300,000 Operating Cycles Selector Non-illuminated 2,000,000 Operating Cycles Switches Illuminated, Key-operated 2,000,000 Operating Cycles Contact Operation Standard Contact Black Logic Reed Wire Gauge #18-12 AWG Terminal Screw Torque 2-10 lb-in / 20 lb-in max; 8 lb-in recommended Locknut Torque 15 ft. lbs. max Temperature Operating 31F to +158F (-35C to +70C) Range Storage 40F to +185F (-40C to +85C) All parts are designed and manufactured of corrosion resistant material or are plated or painted as corrosion protection. All contact block contacts are gold flashed as a standard offering. Internal return spring mechanisms of operators and contact blocks of stainless steel. RoHS Compliant. Declaration of Conformity — The products listed below, to which this declaration relates, are in conformity with the following standards, following the provisions of the Low Voltage Directive (LVD) (73/23/EEC), and the Electromagnetic Compatibility Directive (89/336/EEC.) Products: Contact Blocks: Cat Nos. 52BAE, 52BAH, 52BAJ, 52BAK, 52BAR, 52BAU and 52BJK, with suffixes. Pilot Lights: Cat Nos 52P, with suffixes. Operators: Cat Nos 52S or 52P, with suffixes. Applicable Standards: EN 60947-5-1 Low-Voltage Switchgear and controlgear. Enclosed devices meet the requirements of environmental ratings of IP10, IP11, IP14, IP52, IP54, and IP56. Open devices, when mounted as instructed, in environmental type IP10, IP11, IP14, IP52, IP54 or IP56 enclosures, maintain the environmental requirements for those enclosure types. 2 Siemens Pushbuttons Components Operators Only Complete Units Operator Specific Accessories Contact Blocks 1) Flush Pushbuttons – Non-Illuminated 52P *8*1 * 52P* 8*2 * 52P *8*3 * 52P *8*4 * 52P *8*5 * 52P *8*6 * 52P *8*8 * •• •• •• • Chrome BlackMax 1) Flush 2) Extended A A 1) K X F 2) J A F G B 1 NO 1 NC 1 NO + 1NC 2 NO 2 NC 2 NO + 2 NC Flush Pushbuttons – Non-Illuminated 52P *8*1 52P *8*2 52P *8*3 52P *8*4 52P *8*5 52P *8*6 52P *8*8 Kit All Colors 52P *8*N •• •• •• • Chrome Black Max A X A Flush F Extended Contact Blocks For All Operators 52BAK 1 NO 52BAJ 1 NC 52BJK 1 NO + 1 NC 52BAH 1 NO Early Make 52BAE 1 NC Late Break 52BAU 1 NC Extra Late Break 52BAR 1 NO + 1 NC 2) 1) 2) 52BAR Hermetically Sealed, UL Listed for Class 1, Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt Basic Pushbuttons For Basic Non-Illuminated Pushbuttons 52RA1*1 52RA1*2 52RA1*3 52RA1*4 52RA1*5 52RA1*6 52RA1*8 Kit All Colors 52RA1*N •• •• •• • A Flush F Extended 1) Extended Mushroom Head Momentary Pushbuttons – Non-Illuminated 52P *9*1 * 52P* 9*2 * 52P *9*3 * 52P *9*4 * 52P *9*5 * 52P *9*6 * 52P *9*8 * •• •• •• • Chrome Black Max 1) 1⁵⁄₈” Head 2) 2¹⁄₂” Head B D 1) K X E 2) J A F G B 1 NO 1 NC 1 NO + 1NC 2 NO 2 NC 2 NO + 2 NC Extended Mushroom Head Momentary Pushbuttons – Non-Illuminated 52P *9*1 52P *9*2 52P *9*3 52P *9*4 52P *9*5 52P *9*6 52P *9*8 Kit All Colors 52P *9*N •• •• •• • Chrome Black Max B D 1⁵⁄₈” Head X E 2¹⁄₂” Head Contact Blocks For All Operators 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAU 52BAR 1) 2) 1 NO 1 NC 1 NO + 1 NC 1 NO Early Make 1 NC Late Break 1 NC Extra Late Break 1 NO + 1 NC 2) 52BAR Hermetically Sealed, UL Listed for Class 1, Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt Mushroom Head Buttons For Extended Momentery Pushbuttons 52RB3*1 52RB3*2 52RB3*3 52RB3*4 52RB3*5 52RB3*6 52RB3*8 Kit All Colors 52RB3*N •• •• •• • D 1⁵⁄₈” Head E 2¹⁄₂” Head 1) Illuminated Pushbuttons/Push-to-Test 1 NO + 1 NC ••5252**T6T6**2A 3A 1 NO + 1 NC 1 NO + 1 NC ••5252**T6T6**5A 9A 1 NO + 1 NC + 1 NC ••5252**T6T6**BAAA 11 NO NO + 1 NC 52 *T6*NA 1 NO + 1 NC AMB CL WH Less Lens Chrome BlackMax 1) B 6-8V Full Voltage 2) D 24V Full Voltage 2) G 120V Transformer Type 2) 3) H 240V Transformer Type 2) 3) J 480V Transformer Type 2) 3) K 600V Transformer Type 2) 3) L 24V LED Module M 120V LED Module N 240V LED Module 1) Not available for LED. 2) For LED, add “B” to the end of the assembled number. 3) With 6V lamp. P B Contact Blocks For All Operators 52BAK 1 NO 52BAJ 1 NC 52BJK 1 NO + 1 NC 52BAH 1 NO Early Make 52BAE 1 NC Late Break 52BAU 1 NC Extra Late Break 52BAR 1 NO + 1 NC 2) 1) 2) Illuminated Pushbutton Lenses For Illuminated Pushbuttons/Push-to-test 52RA5P2 52RA5P3 52RA5P5 AMB 52RA5P9 CLR 52RA5PA WH 52RA5PB •• •• •• 52BAR Hermetically Sealed, UL Listed for Class 1, Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt 3 A Pushbutton and Mushroom Head Momentary Non-Illuminated Cat. No. 52PA8, 52PX8, 52PB9, 52PX9 Installation Instructions Units are assembled as shown. 1. Assemble oil rings. 2. Mount unit on panel as shown in illustration. 3. Position trim ring or legend plate (trim ring is discarded when legend plate is used).1) 4. Position index locking ring on unit as shown in illustration. 5. Assemble and tighten lock nut. 6. Position and press on color cap. B Push-to-Test Illuminated Pushbutton Cat. No. 52PT6, 52BT6 Installation Instructions 1. Remove lock nut from operator. Mount operator base panel as shown and tighten to 15 ft. lbs.2) 2. Place lens gasket around lamp, sealing it firmly in a groove provided. 3. Screw lens into threaded socket of operator base and tighten by hand. A 21/8” 21/8” 15/8” 15/8” 15/8” Oil Rings 15/8” This Side Up 1” 4 3/8” 21/4 11/4 1” 2 3/8” 2 3/8” Panel Shaft 11/4 Oil Rings 2 1/4 Color Cap Set Screw 3/32 Wrench .190 .672 .190 21/4 .672 1/16-1/4 Legend plate or Trim ring 1/16-1/4 Panel 21/4 11/4 Trim ring or Legend plate 1.210 Index Locking Ring Lock Nut Index Locking Ring 1.210 Push-Pull Head Lock Nut Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Some accessories also require additional spacing. *Mushroom Head Momentary Operator Mounting. For Operator Dimensional Drawings See Page 1-6. B Installing Guard Accessory (52AAGL) 1. To install guard accessory, replace operator lock nut with lock nut from guard accessory kit. 2. Screw guard on the operator. NOTE: The guard is designed to protect the push button from accidental operation. 1) Second oil ring and trim ring not used on Black Max 4X devices. 2) Spacers and trim ring not used on black 4X devices. Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. Volts 6-8* 24 Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Some accessories also require additional spacing. A Non-illuminated momentary push button flush extended styles with one contact block B Push to test illuminated push button 1.52 (39) 2.25 (57) IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. 1.74 (44) 2.74 (70) 1.09 (28) 1.05 (27) Legend Plates THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. Large Hazardous voltage. Can cause death, serious personal injury, or property damage. To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. 4 Jumbo Automotive B Lamps #755 #1829 Wiring Instructions (Typical Motor Controller Application) Siemens Pilot Lights Components Operators Only Complete Units Pilot Lights Plastic Lens 52*L4*2 52*L4*3 52*L4*5 AMB 52 *L4*9 CL 52*L4*A WH 52*L4*B Less Lens 52*L4*N 1) •• • • •• Chrome BlackMax P B B 6V Full Voltage 2) C 12V Full Voltage 1) 2) D 24V Full Voltage 2) E 120V Full Voltage 2) G 120V Transformer 2) 3) H 240V Transformer 2) 3) J 480V Transformer 2) 3) K 600V Transformer 2) 3) L 24V LED Module 4) M 120V LED Module 4) N 240V LED Module 4) Pilot Lights without Lighting Module Plastic Lens 52*L4X2 52*L4X3 52*L4X5 AMB 52 *L4X9 CL 52*L4XA WH 52*L4XB Less Lens 52*L4XN •• ••• • Chrome BlackMax P B Lighting Modules Full Voltage 52AAF*2B 1) 52AAF*3B 1) 52AAF*5B 1) AMB 52AAF*9B WHT/CLR 52AAF*BB Incandascent2) 52AAF*B •• •• • Transformer AMB WHT/CLR Incandascent2) •• • • •• Chrome BlackMax P B B 6V Full Voltage 2) C 12V Full Voltage 1) 2) D 24V Full Voltage 2) E 120V Full Voltage 2) G 120V Transformer 2) 3) H 240V Transformer 2) 3) K 600V Transformer 2) 3) L 24V LED Module 4) M 120V LED Module 4) N 240V LED Module 4) B 6V D 24V E 120V *2B •• 52AAT 52AAT*3B *4B •• 52AAT 52AAT*5B • 52AAT*BB Pilot Lights without Lighting Module Glass Lens 52*L5X2 52*L5X3 52*L5X5 AMB 52 *L5X9 CL 52*L5XA WH 52*L5XB Less Lens 52*L5XN •• ••• • Chrome BlackMax AMB WHT/CLR Pilot Light Lenses 52RA4*2 52RA4*3 52RA4*5 AMB 52RA4*9 CLR 52RA4*A WHT 52RA4*B •• •• •• S Plastic T Glass 1) 1) 1) 52AAT*B G H J K LED Module Pilot Lights Glass Lens 52*L5*2 52*L5*3 52*L5*5 AMB 52 *L5*9 CL 52 *L5* A WH 52*L5*B Less Lens 52*L5*N 1) Operator Specific Accessories Lighting Modules 120V 240V 480V 600V *2 ••52AAI 52AAI*3 *4 ••52AAI 52AAI*5 •52AAI*B L 24V M 120V N 240V 1) 2) For cluster LED, replace the last digit “B” with a “Y.” All colors can be used with incandescent bulb. P B Not available for LED. For single LED, add ”XB” to end of assembled number. For cluster LED, add ”XY” to end of assembled number. 3) With 6V lamp. 4) Integrated LED module utilizes a single LED. 1) 2) 5 Pilot Light Cat. Nos. 52PL, 52BL Installation Instructions Units are assembled as shown. 1. Assemble oil rings. 2. Mount unit on panel as shown in illustration. 2a. When installing a pilot light in a NEMA 4 plastic or non-corrosive enclosure, a grounding ring and two oil rings must be installed. See Fig. 1A for placement. (Order kit #52AL109145 which includes 1 ground ring and 1 oil ring). 3. Position trim ring or legend plate (trim ring is discarded when legend plate is used). 1) 4. Position index locking ring on unit as shown in illustration. 5. Assemble and tighten lock nut to 15 ft. lbs. 1) Trim ring not used on black 4X devices. Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. Pilot light, plastic lens, transformer or full voltage, lighting module IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. Pilot light, plastic lens, integral LED, lighting module 1.85 (47) 1.94 (49) 1.24 (31) 1.70 (43) 1.09 (28) 1.70 (43) 1.24 (31) 3 1 3.49 (89) 1.00 (25) 3 1 3.31 (84) 1.70 (43) 1.70 (43) Hazardous voltage. Can cause death, serious personal injury, or property damage. Pilot light, glass lens, integral LED, lighting module To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. Pilot light, glass lens, transformer or full voltage, lighting module 1.85 (47) 1.00 (25) 1.70 (43) 1.70 (43) 1.42 (36) 1.42 (36) 3 1 Legend Plates 3.68 (93) 3.50 (89) 1.70 (43) Large 6 Jumbo Automotive 1.63 (41) 1.94 (47) 1.09 (28) Siemens Twist-to-Release Units Components Operators Only Complete Units Operator Specific Accessories Contact Blocks 1) Twist-to-Release Non-Illuminated 52*R8W2A 52*R8W3A 52*R8W5A •• • Chrome BlackMax 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC P B Twist-to-Release Non-Illuminated 52*R8W2 52*R8W3 52*R8W5 •• • Chrome BlackMax P B 1 3/4” Mushroom Head – Plastic For Non-Illuminated Twist-to-Release 52RC3R2 52RC3R3 52RC3R5 Contact Blocks For All Operators 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAU 52BAR 1) •• • 1 NO 1 NC 1 NO + 1 NC 1 NO Early Make 1 NC Late Break 1 NC Extra Late Break 1 NO + 1 NC 1) Hermetically Sealed, UL Listed for Class 1, Division 2, .25A Max., 150V AC, 10 Watt .5A Max., 150V AC, 10 Watt 1) Twist-to-Release Illuminated 52*R8*RA 52*R8*SA AMB 52*R8*TA •• • Chrome BlackMax P B B C D E G H J K L M N 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 6V Full Voltage 2) 12V Full Voltage 1) 2) 24V Full Voltage 2) 120V Full Voltage 2) 120V Transformer Type 2) 3) 240V Transformer Type 2) 3) 480V Transformer Type 2) 3) 600V Transformer Type 2) 3) 24V LED Module 4) 120V LED Module 4) 240V LED Module 4) Not available for LED. For single LED, add ”B” to end of the assembled number. 3) With 6V lamp. 4) Integrated LED module utilizes a single LED. 1) 2) Twist-to-Release Illuminated 52*R8*R 52*R8*S AMB 52*R8*T •• • Chrome BlackMax P B B C D E G H J K L M N 6V Full Voltage 4) 12V Full Voltage 1) 4) 24V Full Voltage 4) 120V Full Voltage 4) 120V Transformer Type 4) 2) 240V Transformer Type 4) 2) 480V Transformer Type 4) 2) 600V Transformer Type 4) 2) 24V LED Module 3) 120V LED Module 3) 240V LED Module 3) Contact Blocks For All Operators 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAU 52BAR 1) 1 NO 1 NC 1 NO + 1 NC 1 NO Early Make 1 NC Late Break 1 NC Extra Late Break 1 NO + 1 NC 1) 1 3/4” Mushroom Head – Plastic For Illuminated Twist-to-Release 52RC3RR 52RC3RS AMB 52RC3RT •• • Hermetically Sealed, UL Listed for Class 1, Division 2, .25A Max., 150V AC, 10 Watt .5A Max., 150V AC, 10 Watt 1) Not available for LED. 2) With 6V lamp. 3) Integrated LED module utilizes a single LED. 4) For a single LED, add “XB” to end of the assembled number. 7 Twist-to-Release Unit Cat. No. 52PR8, 52BR8 A illuminated B Non-illuminated Installation Instructions 1. Remove push-pull head (turn counter clockwise to loosen) 2. Remove locknut, lock ring, and trim ring. 3. Mount unit in panel as shown. Secure locknut to 15 ft.-lbs. 4. Replace push-pull head. Make sure gasket in in place. Contact Operation 1. For normally open contacts, use 52BAK contact block 2. For normally closed contacts, use 52BAJ contact block Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, 1 THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Some accessories also require additional spacing. 1 Illuminated twist-to-release full voltage or transformer Illuminated twist-to-release LED module Ø1.79 (45) Ø1.79 (45) 1.75 (45) 2.25 (57) 1.74 (44) 1.09 (28) Ø1.79 (45) 1.75 (45) 1.75 (45) 1.74 (44) 2.01 (51) 2.74 (70) Hazardous voltage. Can cause death, serious personal injury, or property damage. 1.74 (44) 2.74 (70) 1.00 (25) 1.05 (27) 1.05 (27) To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. Legend Plates Large 8 Non-illuminated twist-to-release Jumbo Automotive 2.74 (70) 1.05 (27) 2.10 (53) Siemens Selector Switches – 2-Position Components Operators Only Complete Units Operator Specific Accessories Contact Blocks 1) 2-Position Selector Switch Non-Illuminated Maintained “A” Cam 52S*2AAB*1 2-Position Selector Switch Non-Illuminated Maintained “A” Cam 52S*2AAB Chrome Short Lever A Chrome Long Lever B Black Max Short Lever X Black Max Long Lever W Chrome Short Lever Chrome Long Lever Black Max Short Lever Black Max Long Lever • K 1 NO J 1 NC A 1 NO + 1 NC • A B X W Spring Return From Right “A” Cam 52S*2ACB*1 Spring Return From Right “A” Cam 52S*2ACB Chrome Short Lever A Chrome Long Lever B Black Max Short Lever X Black Max Long Lever W Chrome Short Lever Chrome Long Lever Black Max Short Lever Black Max Long Lever • K 1 NO J 1 NC A 1 NO + 1 NC • A B X W Contact Blocks For All Operators 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAU 52BAR Lever Inserts For Selector Switches 52RA2*2 52RA2*3 52RA2*4 52RA2*5 52RA2*6 52RA2*8 WHT 52RA2*B •• •• •• • 1 NO 1 NC 1 NO + 1 NC 1 NO Early Make 1 NC Late Break 1 NC Extra Late Break 1 NO + 1 NC 2) 1) 52BAR 2) Hermetically Sealed, UL Listed for Class 1, A Short Lever B Long Lever Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt 1) 2-Position Selector Switch Illuminated Maintained “A” Cam 52SA7A*2A0 1 NO + 1 NC 52SA7A*2A0 1 NO + 1 NC AMB 52SA7A*2A0 1 NO + 1 NC •• • 2-Position Selector Switch without Lens Illuminated Maintained “A” Cam 52SA7A*N D 24V Full Voltage G 120V Transformer H 240V Transformer D 24V Full Voltage G 120V Transformer H 240V Transformer Contact Blocks For All Operators 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAU 52BAR Lens Kit (Knob plus Insert) For Illuminated Selector Switches 52RA6P2 52RA6P3 52RA6P5 AMB 52RA6P9 CLR 52RA6PA WHT 52RA6PB •• •• •• 1 NO 1 NC 1 NO + 1 NC 1 NO Early Make 1 NC Late Break 1 NC Extra Late Break 1 NO + 1 NC 2) 1) 52BAR 2) Hermetically Sealed, UL Listed for Class 1, Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt 1) 2-Position Key Selector Switch Maintained “A” Cam 52SC6AF*1 • K 1 NO J 1 NC A 1 NO + 1 NC Spring Return From Right “A” Cam 52SC6AX*1 • K 1 NO J 1 NC A 1 NO + 1 NC 2-Position Key Selector Switch Maintained “A” Cam 52SC6A* • E All Key Removal F Left Key Removal Contact Blocks For All Operators 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAU 52BAR 1 NO 1 NC 1 NO + 1 NC 1 NO Early Make 1 NC Late Break 1 NC Extra Late Break 1 NO + 1 NC 2) 1) 52BAR 2) Hermetically Sealed, UL Listed for Class 1, Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt 9 A Selector Operators — Non-Illuminated A Selector Operators — Non-illuminated Cat. No. 52SA2, 52SB2, 52SX2, 52SW2 and 52SC6 For Contact and Cam Selection for Non-Illuminated Selector and Key Operators, see Page 1-28 21/8” 15/8” 15/8” B Selector Operators — Illuminated 1” Cat. No. 52SA7 For Contact and Cam Selection for Illuminated Selector Operators, see Page 1-28 Installation Instructions Units are assembled as shown. 1. Position and press in color insert if required. 2. Assemble oil rings. 3. Mount unit on panel as shown in the illustration. 4. Position trim ring or legend plate (trim ring is discarded when legend plate is used).1) 5. Position index locking ring on unit as shown in illustration. 2) 6. Assemble and tighten lock nut to 15 ft. lbs. 43/8” 23/8” To add another color insert, remove unit from panel and pry out white insert with small screwdriver. Snap in new color insert. Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. 1) Trim ring not used on black 4X devices. 2) Locking ring not needed with plastic legend plates. Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. Hazardous voltage. Can cause death, serious personal injury, or property damage. B Selector Operators — Illuminated 115/16” 15/8” 15/8” Volts 6-8* 24 120 1” 43/8” Lamps #755 #1829 #120MB *Also transformer type 23/8” Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Selector switches and keyed selector switches illuminated and non-illuminated Legend Plates To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. Large 10 Jumbo Automotive Siemens Selector Switches – 3-Position Components Operators Only Complete Units 3-Position Selector Switch Non-Illuminated Maintained 52S*2 * AB * • Chrome Short Lever Chrome Long Lever Black Max Short Lever Black Max Long Lever A C 1) B G 1) X W Operator Specific Accessories Contact Blocks 3-Position Selector Switch Non-Illuminated Maintained 52S*2 * AB A1 1 NO + 1 NC A2 2 NO + 2 NC J2K12 NC + 1 NO • Chrome Short Lever Chrome Long Lever Black Max Short Lever Black Max Long Lever A B X W 1) Cam code B 1) C 1) D 1) E 1) G 1) 1) 1) Cam code Spring Return From Right 52S*2 * CB * • Chrome Short Lever Chrome Long Lever Black Max Short Lever Black Max Long Lever A C 1) B G 1) X J2 W A1 A2 K1 Spring Return From Right 52S*2 * CB 1 NO + 1 NC 2 NO + 2 NC 2 NC + 1 NO • Chrome Short Lever Chrome Long Lever Black Max Short Lever Black Max Long Lever A B X W B 1) C 1) D 1) E 1) G 1) 1) Cam code 1) Cam code Spring Return From Left 52S*2 * BB * • Chrome Short Lever Chrome Long Lever Black Max Short Lever Black Max Long Lever A C 1) B G 1) X W A1 1 NO + 1 NC A2 2 NO + 2 NC J2K1 2 NC + 1 NO 1) Cam code Spring Return From Left 52S*2 * BB • Chrome Short Lever Chrome Long Lever Black Max Short Lever Black Max Long Lever A B X W B 1) C 1) D 1) E 1) G 1) Lever Inserts For Selector Switches 52RA2*2 52RA2*3 52RA2*4 52RA2*5 52RA2*6 52RA2*8 WHT 52RA2*B Contact Blocks For All Operators 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAU 52BAR •• •• ••• 1 NO 1 NC 1 NO + 1 NC 1 NO Early Make 1 NC Late Break 1 NC Extra Late Break 1 NO + 1 NC 2) 1) 52BAR 2) Hermetically Sealed, UL Listed for Class 1, A Short Lever B Long Lever Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt 1) Cam code Spring Return From Right and Left 52S*2 * DB * • Chrome Short Lever Chrome Long Lever Black Max Short Lever Black Max Long Lever A C 1) B G 1) X W A1 1 NO + 1 NC A2 2 NO + 2 NC J2K1 2 NC + 1 NO Spring Return From Right and Left 52S*2 * DB • Chrome Short Lever Chrome Long Lever Black Max Short Lever Black Max Long Lever A B X W B 1) C 1) D 1) E 1) G 1) 1) Cam code 1) Cam code 1) 3-Position Selector Switch Illuminated Maintained 52SA7* * 2 52SA7* * 3 52SA7* * 9 3-Position Selector Switch without Lens Illuminated Maintained 52SA7* *N B 1) D 24V Full Voltage C 1) G 120V Full Voltage Transformer H 240V Transformer B 1) D 24V Full Voltage C 1) G 120V Transformer H 240V Transformer 1) Cam code 1) Cam code Contact Blocks For All Operators 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAU 52BAR 1 NO 1 NC 1 NO + 1 NC 1 NO Early Make 1 NC Late Break 1 NC Extra Late Break 1 NO + 1 NC 2) Lens Kit (Knob plus Insert) For Illuminated Selector Switches AMB CL WH ••52RA6P2 52RA6P3 52RA6P5 • 52RA6P9 • •• 52RA6PA 52RA6PB 1) 52BAR 2) Hermetically Sealed, UL Listed for Class 1, Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt 11 A Selector Operators — Non-illuminated A Selector Operators — Non-illuminated Cat. No. 52SA2, 52SB2, 52SX2, 52SW2 and 52SC6 For Contact and Cam Selection for Non-Illuminated Selector and Key Operators, see Page 1-28 21/8” 15/8” 15/8” B Selector Operators — Illuminated 1” Cat. No. 52SA7 For Contact and Cam Selection for Illuminated Selector Operators, see Page 1-28 Installation Instructions Units are assembled as shown. 1. Position and press in color insert if required. 2. Assemble oil rings. 3. Mount unit on panel as shown in the illustration. 4. Position trim ring or legend plate (trim ring is discarded when legend plate is used).1) 5. Position index locking ring on unit as shown in illustration.2) 6. Assemble and tighten lock nut to 15 ft. lbs. 1) Trim ring not used on black 4X devices. 2) Locking ring not needed with plastic legend plates. Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. Hazardous voltage. Can cause death, serious personal injury, or property damage. 43/8” 23/8” To add another color insert, remove unit from panel and pry out white insert with small screwdriver. Snap in new color insert. Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. B Selector Operators — Illuminated 115/16” 15/8” 15/8” Volts 6-8* 24 120 1” 43/8” Lamps #755 #1829 #120MB *Also transformer type 23/8” Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Selector switches and keyed selector switches illuminated and non-illuminated Legend Plates To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. Large 12 Jumbo Automotive Siemens Selector Switches – 3-Position Components Operators Only Complete Units 3-Position Key Selector Switch Maintained ••52SC6CEA1 52SC6CEJ2K1 •52SC6CEA2 1 NO + 1 NC 1 NO + 2 NC 2 NO + 2 NC Operator Specific Accessories Contact Blocks 3-Position Key Selector Switch Maintained 52SC6 * * • 1) Cam Code B 1) C 1) D 1) E 1) G 1) E F G H J All Key Removal Left Key Removal Right Key Removal Center Key Removal Left and Right Key Removal K Left and Center Key Removal M Right and Center Key Removal 1) Spring Return From Right 52SC6CZA1 1 NO + 1 NC 52SC6GZJ2K1 1 NO + 2 NC 52SC6CZA2 2 NO + 2 NC •• • Spring Return From Right 52SC6 * * • B 1) U Center Key Removal C 1) Z Left and Center Key Removal D 1) E 1) G 1) 1) Cam Code Spring Return From Left 52SC6 * * • 1) Cam Code Spring Return From Right and Left 52SC6CVA1 1 NO + 1 NC 52SC6GVJ2K1 1 NO + 2 NC 52SC6CVA2 2 NO + 2 NC •• • B 1) T C 1) W D1) Y E 1) G1) Contact Blocks For All Operators 52BAK 1 NO 52BAJ 1 NC 52BJK 1 NO + 1 NC 52BAH 1 NO Early Make 52BAE 1 NC Late Break 52BAU 1 NC Extra Late Break 52BAR 1 NO + 1 NC 2) 1) 52BAR 2) Hermetically Sealed, UL Listed for Class 1, Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt Center Key Removal Right Key Removal Right and Center Key Removal Spring Return From Right and Left 52SC6 * * • B 1) V Center Key Removal C 1) D 1) E 1) G 1) 1) Cam Code 13 Selector Operators — Non-Illuminated Cat. No. 52SC6 For Contact and Cam Selection for Non-Illuminated Selector and Key Operators, see Page 1-28. Installation Instructions Units are assembled as shown. 1. Position and press in color insert if required. 2. Assemble oil rings. 3. Mount unit on panel as shown in the illustration. 4. Position trim ring or legend plate (trim ring is discarded when legend plate is used). 1) 5. Position index locking ring on unit as shown in illustration. 2) 6. Assemble and tighten lock nut to 15 ft. lbs. 21/8” 15/8” 15/8” 1” 43/8” 23/8” 1) Trim ring not used on black 4X devices. 2) Locking ring not needed with plastic legend plates Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. Hazardous voltage. Can cause death, serious personal injury, or property damage. To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. 14 To add another color insert, remove unit from panel and pry out white insert with small screwdriver. Snap in new color insert. Selector switches and keyed selector switches illuminated and non-illuminated Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Legend Plates Large Jumbo Automotive Siemens Selector Switches — 4-Position and Specialty Complete Units Components Operators Only Operator Specific Accessories Contact Blocks 1) 4-Position Selector Switch Non-Illuminated Maintained 52S*2HAB • Chrome Short Lever Chrome Long Lever Black Max Short Lever Black Max Long Lever A B X W Contact Blocks For All Operators 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAU 52BAR 1 NO 1 NC 1 NO + 1 NC 1 NO Early Make 1 NC Late Make 1 NC Extra Late Break 1 NO + 1 NC 2) 1) 52BAR 2) Hermetically Sealed, UL Listed for Class 1, Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt Select/Push Operator Non-Illuminated Maintained 52SA** 1 52SA** 2 Flush Raised •• 3 P 1) 4 Q 1) R 1) S 1) 1) Cam code 15 Selector Operators — Non-Illuminated Cat. No. 52SA2H, 52SB2H, 52SX2H, 52SW2H, 52SA3, 52SA4 For Contact and Cam Selection for Non-Illuminated Selector and Key Operators, see Page 1-28. Installation Instructions Units are assembled as shown. 1. Position and press in color insert if required. 2. Assemble oil rings. 3. Mount unit on panel as shown in the illustration. 4. Position trim ring or legend plate (trim ring is discarded when legend plate is used). 1) 5. Position index locking ring on unit as shown in illustration. 2) 6. Assemble and tighten lock nut to 15 ft. lbs. 21/8” 15/8” 15/8” 1” 43/8” 23/8” 1) Trim ring not used on black 4X devices. 2) Locking ring not needed with plastic legend plates Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. To add another color insert, remove unit from panel and pry out white insert with small screwdriver. Snap in new color insert. Selector Push Operator Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Legend Plates THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. Large Hazardous voltage. Can cause death, serious personal injury, or property damage. To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. Selector switches and keyed selector switches illuminated and non-illuminated 16 Jumbo Automotive Siemens Push-Pull Units Complete Units Components Operators Only Operator Specific Accessories Contact Blocks 1) 2-Position Push-Pull; Maintained Non-Illuminated 1³⁄₄” Metal Mushroom Head Less Head 52*P2AZA 1 NO + 1 NC MTL 52*P2A2A 1 NO + 1 NC MTL 52*P2A3A 1 NO + 1 NC MTL 52*P2ACA 1 NO + 1 NC 2-Position Push-Pull; Maintained Non-Illuminated 1³⁄₄” Metal Mushroom Head Less Head 52*P2AZ MTL 52*P2A2 MTL 52*P2A3 MTL 52*P2AC Chrome BlackMax Chrome BlackMax ••• P B •• • P B 1³⁄₄” Plastic Mushroom Head Less Head 52*P2WZA 1 NO + 1 NC 52*P2W1A 1 NO + 1 NC 52*P2W2A 1 NO + 1 NC 52*P2W3A 1 NO + 1 NC 1³⁄₄” Plastic Mushroom Head Less Head 52*P2WZ 52*P2W1 52*P2W2 52*P2W3 Chrome BlackMax Chrome BlackMax •• • P B 2¹⁄₂” Plastic Mushroom Head Less Head 52*P2VZA 1 NO + 1 NC 52*P2V1A 1 NO + 1 NC 52*P2V2A 1 NO + 1 NC 52*P2V3A 1 NO + 1 NC •• • Chrome BlackMax P B 3-Position Push-Pull; Momentary Non-Illuminated 1³⁄₄” Metal Mushroom Head Less Head 52*P3AZU 1 NO + 1 NCXLB1) 3TL 52*P3A1U 1 NO + 1 NCXLB1) CTL 52*P3A2U 1 NO + 1 NCXLB1) MTL 52*P3A3U 1 NO + 1 NCXLB1) •• • Chrome Black Max P B 1³⁄₄” Plastic Mushroom Head Less Head 52*P3WZU 1 NO + 1 NCXLB1) 52*P3W1U 1 NO + 1 NCXLB1) 52*P3W2U 1 NO + 1 NCXLB1) 52*P3W3U 1 NO + 1 NCXLB1) •• • Chrome BlackMax •• • Chrome BlackMax 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAU 52BAR 1 NO 1 NC 1 NO + 1 NC 1 NO Early Make 1 NC Late Break 1 NC Extra Late Break 1 NO + 1 NC 2) 1) 52BAR 2) Hermetically Sealed, UL Listed for Class 1, Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt 1³⁄₄” Mushroom Head – Plastic For Non-Illuminated Push-Pull 52RC3D1 52RC3D2 52RC3D3 52RC3D4 52RC3D5 52RC3D6 52RC3D8 Kit All Colors 52RC3DN •• •• •• • P B 2¹⁄₂” Plastic Mushroom Head Less Head 52*PAVZ 52*P2V1 52*P2V2 52*P2V3 •• • Contact Blocks For All Operators P B 1³⁄₄” Mushroom Head – Metal For Non-Illuminated Push-Pull MTL 52RC2FC MTL 52RC2F2 MTL 52RC2F3 •• • 2¹⁄₂ “ Mushroom Head – Plastic For Non-Illuminated Push-Pull 52RC3E1 52RC3E2 52RC3E3 52RC3E4 52RC3E5 52RC3E6 52RC3E8 Kit All Colors 52RC3EN •• •• •• • P B 2¹⁄₂” (57.2mm) Plastic Mushroom Head Less Head 52*P3VZU 1 NO + 1 NCXLB1) 52*P3V1U 1 NO + 1 NCXLB1) 52*P2V2U 1 NO + 1 NCXLB1) 52*PCV3U 1 NO + 1 NCXLB1) •• • Chrome Black Max P B 1) Blocks cannot be interchanged (start-stop) circuit. 17 Non-Illuminated Push-Pull Operators 2 Position Maintained, 3 Position Momentary Cat. No. 52PP2A, 52PP2W, 52PP2V, 52PP3A, 52PP3W, 52PP3V, 52BP2A, 52BP2W, 52BP2V, 52BP3A, 52BP3W, 52BP3V Installation Instructions 1. Remove push-pull head (turn counter clockwise to loosen). 2. Remove locknut, lock ring, and trim ring. 3. Mount unit in panel as shown. Secure locknut to 15 ft.-lbs. 4. Replace push-pull head. Make sure gasket in in place. Contact Operation Maintained Push-Pull 1. For normally open contacts, use 52BAK contact block. 2. For normally closed contacts, use 52BAJ contact block. Momentary Push-Pull (Factory assembled) 1. For normally open contacts, the 52BAJ (normally closed) contact block is used. When mounted on this operator, the contact block becomes normally open. 2. For normally closed contacts, the special 52BAU contact block is used. This contact block must be mounted last. Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Some accessories also require additional spacing. 1 3/4" mushroom head push-pull non-illuminated 2 1/2" mushroom head push-pull non-illuminated Ø1.75 (44) Ø2.50 (64) 1.75 (45) 1.75 (45) 1.74 (44) 1.74 (44) 2.74 (70) 2.74 (70) 1.05 (27) 2.10 (53) 1.05 (27) 2.10 (53) Legend Plates Hazardous voltage. Can cause death, serious personal injury, or property damage. To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. 18 Large Automotive Siemens Push-Pull Units Components Operators Only Complete Units Operator Specific Accessories Contact Blocks 1) 2-Position Push-Pull; Maintained Illuminated 1 ³⁄₄” Metal Mushroom Head Less Head 52*P2*ZA 1 NO + 1 NC 52*P2*2A 1 NO + 1 NC 52*P2*3A 1 NO + 1 NC AMB 52*P2*9A 1 NO + 1 NC •• • Chrome BlackMax P B D G H J K L M N 24V Full Voltage 1) 120V Transformer 1) 2) 240V Transformer 1) 2) 480V Transformer 1) 2) 600V Transformer 1) 2) 24V LED Module 3) 120V LED Module 3) 240V LED Module 3) 1 ³⁄₄” Plastic Mushroom Head Less Head 52*P2*ZA 1 NO + 1 NC 52*P2*RA 1 NO + 1 NC 52*P2*SA 1 NO + 1 NC AMB 52*P2*TA 1 NO + 1 NC •• • Chrome BlackMax P B D G L M 24V Full Voltage 1) 120V Transformer 1) 2) 24V LED Module 3) 120V LED Module 3) 2 ¹⁄₂” Plastic Mushroom Head Less Head 52*P2*PA 1 NO + 1 NC 52*P2*DA 1 NO + 1 NC 52*P2*EA 1 NO + 1 NC AMB 52*P2*FA 1 NO + 1 NC •• • Chrome BlackMax P B D G L M 24V Full Voltage 1) 120V Transformer 1) 2) 24V LED Module 3) 120V LED Module 3) 1) For LED, add “B” to the end of assembled number. 2) With 6V lamp. 3) With single LED. 2-Position, Maintained Push-Pull Illuminated 1 ³⁄₄” Metal Mushroom Head Less Head 52*P2*Z 52*P2*2 52*P2*3 AMB 52*P2*9 •• • Chrome BlackMax P B D G H J K L M N 24V Full Voltage 1) 120V Transformer 1) 2) 240V Transformer 1) 2) 480V Transformer 1) 2) 600V Transformer 1) 2) 24V LED Module 3) 120V LED Module 3) 240V LED Module 3) 1 ³⁄₄” Plastic Mushroom Head Less Head 52*P2*Z 52*P2*R 52*P2*S AMB 52*P2*T •• • Chrome BlackMax P B D G L M 24V Full Voltage 1) 120V Transformer 1) 2) 24V LED Module 3) 120V LED Module 3) 2 ¹⁄₂” Plastic Mushroom Head Less Head 52*P2*Z 52*P2*D 52*P2*E AMB 52*P2*F •• • Chrome BlackMax P B D G L M 24V Full Voltage 1) 120V Transformer 1) 2) 24V LED Module 3) 120V LED Module 3) Contact Blocks For All Operators 52BAK 52BAJ 52BJK 52BAH 52BAE 52BAU 52BAR 1 NO 1 NC 1 NO + 1 NC 1 NO Early Make 1 NC Late Break 1 NC Extra Late Break 1 NO + 1 NC 2) 1) 52BAR 2) Hermetically Sealed, UL Listed for Class 1, 1³⁄₄” Mushroom Head – Metal For Illuminated Push-Pull 52R*3H2 52R*3H3 52R*3H5 AMB 52R*3H9 CLR 52R*3HA WHT 52R*3HB •• •• •• Chrome BlackMax B X Division 2, .25A Max., 200V AC, 10 Watt .5A Max., 200V AC, 10 Watt 1³⁄₄” Mushroom Head – Plastic For Illuminated Push-Pull 52RC3JR 52RC3JS AMB 52RC3JT •• • 2¹⁄₂” Plastic Mushroom Head For Illuminated Push-Pull 52RC3KR 52RC3KS AMB 52RC3KT •• • 1) For LED, add “XB” to the end of assembled number. 2) With 6V lamp. 3) With single LED. 19 Illuminated Push-Pull Operators 2 Position Maintained Cat. No. 52PP2, 52BP2 Installation Instructions 1. Remove push-pull head (turn counter clockwise to loosen). 2. Remove locknut, lock ring, and trim ring. 3. Mount unit in panel as shown. Secure locknut to 15 ft.-lbs. 4. Replace push-pull head. Make sure gasket in in place. Contact Operation 1. For normally open contacts,use 52BAK contact block 2. For normally closed contacts, use 52BAJ contact block Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. Hazardous voltage. Can cause death, serious personal injury, or property damage. To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Some accessories also require additional spacing. 1 3/4" plastic mushroom head push-pull illuminated 1 3/4" metal mushroom head push-pull illuminated Ø1.75 (45) Ø1.75 (45) 1.88 (48) 1.75 (45) 2.25 (57) 1.74 (44) 1.74 (44) 2.25 (57) 2.74 (70) 1.09 (28) 2.74 (70) 1.05 (27) 1.09 (28) 1.05 (27) Legend Plates Large 20 Jumbo Automotive Wiring Contact Position Maintained 2 Position Siemens Push-Pull Operators Components Operators Only Complete Units 3-Position Push-Pull; Momentary Illuminated 1 ³⁄₄” Metal Mushroom Head Less Head 52*P3*ZU 1 NO + 1 NCXLB 3) 52*P3*2U 1 NO + 1 NCXLB 3) 52*P3*3U 1 NO + 1 NCXLB 3) AMB 52*P3*9U •• • Chrome BlackMax P B D 24V Full Voltage 1) G 120V Transformer 1) 2) H 240V Transformer 1) 2) J 480V Transformer 1) 2) K 600V Transformer 1) 2) L 24V LED Module 4) M 120V LED Module 4) N 240V LED Module 4) 1 ³⁄₄” Plastic Mushroom Head Less Head 52*P3*ZU 1 NO + 1 NCXLB 3) 52*P3*RU 1 NO + 1 NCXLB 3) 52*P3*SU 1 NO + 1 NCXLB 3) AMB 52*P3*TU 1 NO + 1 NCXLB 3) •• • Chrome BlackMax P B •• • P B Operator Specific Accessories 1³⁄₄” Mushroom Head – Metal For Illuminated Push-Pull 52R*3H2 52R*3H3 52R*3H5 AMB 52R*3H9 CLR 52R*3HA WHT 52R*3HB •• •• •• Chrome BlackMax B X 1³⁄₄” Plastic Mushroom Head For Illuminated Push-Pull 52RC3JR 52RC3JS AMB 52RC3JT •• • D 24V Full Voltage 1) G 120V Transformer 1) 2) L 24V LED Module 4) M 120V LED Module 4) 2 ¹⁄₂” Plastic Mushroom Head Less Head 52*P3*ZU 1 NO + 1 NCXLB 3) 52*P3*DU 1 NO + 1 NCXLB 3) 52*P3*EU 1 NO + 1 NCXLB 3) AMB 52*P3*FU 1 NO + 1 NCXLB 3) Chrome BlackMax Contact Blocks D 24V Full Voltage 1) G 120V Transformer 1) 2) L 24V LED Module 4) M 120V LED Module 2¹⁄₂” Plastic Mushroom Head For Illuminated Push-Pull 52RC3KR 52RC3KS AMB 52RC3KT •• • 1) For LED, add “B” to the end of assembled number. 2) With 6V lamp. 3) Blocks cannot be interchanged (start-stop circuit). 4) With single LED. 21 Illuminated Push-Pull Operators 3 Position Momentary Cat. No. 52PP3, 52BP3 Installation Instructions 1. Remove push-pull head (turn counter clockwise to loosen). 2. Remove locknut, lock ring, and trim ring. 3. Mount unit in panel as shown. Secure locknut to 15 ft.-lbs. 4. Replace push-pull head. Make sure gasket in in place. Contact Operation 1. For normally open contacts, the 52BAJ (normally closed) contact block is used. When mounted on this operator, the contact block becomes normally open. 2. For normally closed contacts, the special 52BAU contact block is used. This contact block must be mounted last. Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Some accessories also require additional spacing. IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. 1 3/4" metal mushroom head illuminated 1 3/4" plastic mushroom head illuminated Ø1.75 (45) Ø1.75 (45) 1.88 (48) 1.75 (45) 2.25 (57) Momentary Contact 3 Position 1.74 (44) 1.74 (44) 2.25 (57) 2.74 (70) 1.09 (28) 2.74 (70) 1.05 (27) 1.09 (28) 1.05 (27) Hazardous voltage. Can cause death, serious personal injury, or property damage. To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. Legend Plates Large 22 Jumbo Automotive Siemens Push-Pull Units Complete Units 3-Position Push-Pull; Push Maintained, Pull Momentary Non-Illuminated 1³⁄₄” Metal Mushroom Head Less head 52*P7AZU 1 NO + 1 NCXLB MTL 52*P7A2U 1 NO + 1 NCXLB 1) MTL 52*P7A3U 1 NO + 1 NCXLB 1) MTL 52*P7ACU 1 NO + 1 NCXLB 1) •• • Chrome BlackMax P B Components Operators Only Contact Blocks Operator Specific Accessories 1³⁄₄” Mushroom Head – Plastic For Non-Illuminated Pushbuttons 52RC3D1 52RC3D2 52RC3D3 52RC3D4 52RC3D5 52RC3D6 52RC3D8 Kit all colors 52RC3DN •• •• •• • 1³⁄₄” Plastic Mushroom Head Less head 52*P7WZU 1 NO + 1 NCXLB 52*P7W2U 1 NO + 1 NCXLB 1) 52*P7W3U 1 NO + 1 NCXLB 1) 52*P7WCU 1 NO + 1 NCXLB 1) •• • Chrome BlackMax P B 2¹⁄₂” Plastic Mushroom Head Less head 52*P7VZU 1 NO + 1 NCXLB 52*P7V2U 1 NO + 1 NCXLB 1) 52*P7V3U 1 NO + 1 NCXLB 1) 52*P7V3U 1 NO + 1 NCXLB 1) •• • Chrome BlackMax P B 1³⁄₄” Mushroom Head – Metal For Non-Illuminated Pushbuttons MTL 52RC2FC MTL 52RC2F2 MTL 52RC2F3 •• • 1) Blocks cannot be interchanged (start-stop circuit). 2¹⁄₂” Mushroom Head – Plastic For Non-Illuminated Pushbuttons 52RC3E1 52RC3E2 52RC3E3 52RC3E4 52RC3E5 52RC3E6 52RC3E8 Kit all colors 52RC3EN •• •• •• • 23 Non-Illuminated Push-Pull Units 3 Position Push-Maintained, Pull-Momentary Cat. No. 52PP7A, 52PP7W, 52PP7V, 52BP7A, 52BP7W, 52BP7V Installation Instructions 1. Remove push-pull head (turn counter clockwise to loosen). 2. Remove locknut, lock ring, and trim ring. 3. Mount unit in panel as shown. Secure locknut to 15 ft.-lbs. 4. Replace push-pull head. Make sure gasket in in place. Contact Operation 1. For normally open contacts, the 52BAJ (normally closed) contact block is used. When mounted on this operator, the contact block becomes normally open. 2. For normally closed contacts, the special 52BAU contact block is used. This contact block must be mounted last. Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Some accessories also require additional spacing. 1 3/4" plastic mushroom head illuminated 1.75 (45) To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. 24 Legend Plates Ø2.50 (64) Ø1.75 (44) 1.75 (45) Large 1.74 (44) 1.74 (44) 2.74 (70) 2.74 (70) 1.05 (27) 2.10 (53) Hazardous voltage. Can cause death, serious personal injury, or property damage. 2 1/2" plastic mushroom head illuminated 1.05 (27) 2.10 (53) Automotive Jumbo Siemens Push-Pull Units Components Operators Only Complete Units 3-Position Push-Pull; Push-Maintained, Pull-Momentary Illuminated 1 ³⁄₄” Metal Mushroom Head Less Head 52*P7*NU 1 NO + 1 NCXLB 3) 52*P7*2U 1 NO + 1 NCXLB 3) 52*P7*3U 1 NO + 1 NCXLB 3) AMB 52*P7*9U 1 NO + 1 NCXLB 3) •• • Chrome BlackMax P B D G H J K L M N 24V Full Voltage 1) 120V Transformer 1) 2) 240V Transformer 1) 2) 480V Transformer 1) 2) 600V Transformer 1) 2) 24V LED Module 4) 120V LED Module 4) 240V LED Module 4) 1 ³⁄₄” Plastic Mushroom Head Less Head 52*P7*NU 1 NO + 1 NCXLB 3) 52*P7*RU 1 NO + 1 NCXLB 3) 52*P7*SU 1 NO + 1 NCXLB 3) AMB 52*P7*TU 1 NO + 1 NCXLB 3) •• • Chrome BlackMax P B D G L M 24V Full Voltage 1) 120V Transformer 1) 2) 24V LED Module 4) 120V LED Module 4) 2 ¹⁄₂” Plastic Mushroom Head Less Head 52*P7*NU 1 NO + 1 NCXLB 3) 52*P7*DU 1 NO + 1 NCXLB 3) 52*P7*EU 1 NO + 1 NCXLB 3) AMB 52*P7*FU •• • Chrome BlackMax 1) 2) 3) 4) P B D G L M 24V Full Voltage 1) 120V Transformer 1) 2) 24V LED Module 4) 120V LED Module 4) Contact Blocks Operator Specific Accessories 1³⁄₄” Metal Mushroom Head For Illuminated Push-Pull 52R*3H2 52R*3H3 52R*3H5 AMB 52R*3H9 CLR 52R*3HA WHT 52R*3HB •• •• •• Chrome BlackMax P B 1³⁄₄” Plastic Mushroom Head For Illuminated Push-Pull 52RC3JR 52RC3JS AMB 52RC3JT •• • 2¹⁄₂” Plastic Mushroom Head For Illuminated Push-Pull 52RC3KR 52RC3KS AMB 52RC3KT •• • For LED, add “B” to the end of assembled number. With 6V lamp. Blocks cannot be interchanged (start-stop circuit). With single LED. 25 Illuminated Push Pull Units 3 Position Push-Maintained, Pull-Momentary Cat. No. 52PP7, 52BP7 Installation Instructions 1. Remove push-pull head (turn counter clockwise to loosen). 2. Remove locknut, lock ring, and trim ring. 3. Mount unit in panel as shown. Secure locknut to 15 ft.-lbs. 4. Replace push-pull head. Make sure gasket in in place. Contact Operation 1. For normally open contacts, the 52BAJ (normally closed) contact block is used. When mounted on this operator, the contact block becomes normally open. 2. For normally closed contacts, the special 52BAU contact block is used. This contact block must be mounted last. Notes for BlackMax 4X devices: • The trim ring is not needed or supplied. • Only use the index locking ring when using a metal nameplate. Discard when not using a name plate or when using a plastic nameplate. • Use locknut wrench, 52MAWB. Typical spacing shown. Automotive legend requires 2¹⁄₂” spacing. Some accessories also require additional spacing. 1 3/4" plastic mushroom head illuminated 1 3/4" metal mushroom head illuminated Ø1.75 (45) IMPORTANT THESE INSTRUCTIONS DO NOT PURPORT TO COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT, NOR TO PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION, OPERATION OR MAINTENANCE. SHOULD FURTHER INFORMATION BE DESIRED OR SHOULD PARTICULAR PROBLEMS ARISE WHICH ARE NOT COVERED SUFFICIENTLY FOR THE PURCHASER’S PURPOSES, THE MATTER SHOULD BE REFERRED TO THE LOCAL SIEMENS SALES OFFICE. 1.74 (44) 1.74 (44) 2.25 (57) 2.74 (70) 1.09 (28) 26 1.88 (48) Large THE CONTENTS OF THIS INSTRUCTION MANUAL SHALL NOT BECOME PART OF OR MODIFY ANY PRIOR OR EXISTING AGREEMENT COMMITMENT OR RELATIONSHIP. THE SALES CONTRACT CONTAINS THE ENTIRE OBLIGATION OF SIEMENS. THE WARRANTY CONTAINED IN THE CONTRACT BETWEEN THE PARTIES IS THE SOLE WARRANTY OF SIEMENS. ANY STATEMENTS CONTAINED HEREIN DO NOT CREATE NEW WARRANTIES OR MODIFY THE EXISTING WARRANTY. To avoid electrical shock, turn off electrical power to controls before performing installation maintenance. Ø1.75 (45) 1.75 (45) 2.25 (57) Hazardous voltage. Can cause death, serious personal injury, or property damage. Legend Plates 1.05 (27) 2.74 (70) 1.09 (28) Momentary Contact 3 Position Non-Illuminated 1.05 (27) Automotive Jumbo General Accessories Lamps Incandescent 52AABN 52AABNF 52AACN 52AADN 52AAENC1 52AAPN Lamps LED 6V, Type 755 6V, Flashing, Type 267 12V, Type 756 24V, Type 757 120V, Type 120MB 120V, Neon Legend Plates for Class 51 and Class 52 30mm Pilot Devices Blank 52N*02 52N*02R Blank (red) 52N*02B Blank (black) 52N*18 Close 52N*10 Down 52N*16 Emerg Stop 52N*16R Emerg Stop (red) 52N*33 Fast-Slow 52N*05 Forward 52N*38 For-Off-Rev 52N*31 For-Rev 52N*37 Hand-Off-Auto 52N*07 High 52N*30 High-Low 52N*44 High-Off-Low 52N*21 In 52N*13 Jog 52N*24 Jog-Forward 52N*25 Jog-Reverse 52N*08 Low 52N*20 Lower 52N*35 Man-Auto 52N*12 Off 52N*26 Off-On 52N*11 On 52N*40 On-Off-Auto 52N*17 Open 52N*34 Open-Close 52N*41 Open-Off-Close 52N*22 Pull to Start Out 52N*47 Push to Stop/Pull to Start 52N*19 Raise 52N*36 Raise-Lower 52N*14 Reset 52N*06 Reverse 52N*23 Run 52N*29 Run-Jog 52N*27 Safe-Run 52N*39 Slow-Off-Fast 52N*03 Start 52N*28 Start-Jog 52N*32 Start-Stop 52N*04 Stop 52N*04R Stop (red) 52N*09 Up 52N*49 Up-Down 52N*42 Up-Off-Down L Large Metal (1 ⁷⁄₁₆” x 2”) A Automotive (2 ⁷⁄₁₆” x 2 ⁷⁄₁₆”) WH •• •• • Protective Boot (52AABA) Lamps LED Cluster •• • 52A *2 52A *3 52A *4 52A*5 52A*B B 6V UC D 24V UC E 120V AC Pushbutton Guard (52AAGP) Padlock Attachment (52AALA) Lens Guard (52AAGM) Padlock Attachment (52AALS) Enclosures # of Holes P30EMS *** 52A *27 52A *37 52A *47 0 0 0 0 0 0 1 1 B 6V UC D 24V UC E 120V AC Locknut (Pushbutton Replacement Front Ring 52AANP) Padlock Attachment (52AALE) 1 _ NEMA 12/13 2 D NEMA 12/13 Extra Deep 3 4 NEMA 4/4X Stainless Steel 4 X NEMA 4/4X Fiberglass 6 9 2 6 Locknut (Mushroom Head and Pilot Light Replacement Front Ring 52AANL) Hole Plugs (52AAH6) Lock Wrench (52MAWB) Locknut (Selector Switch Replacement Front Ring 52AANS) Grounding Kit (52AL109145) Protective Boot (offers protection from ice and foreign substances from interfering with button operation) 52AABA Clear protective boot offering protection from ice and foreign substances from interfering with button operation 52AAB1 Black protective boot Pushbutton Guard (Prevents accidental operation of pushbuttons) 52AAGP Non-Illuminated pushbuttons; Command/52 52AXGP Non-Illuminated pushbuttons; Black Max Lens Guard 52AAGL Illuminated pushbuttons and push to test and pilot lights; Command/52 52AXGL Illuminated pushbuttons and push to test and pilot lights; BlackMax Mushroom Head Pushbutton Guard 52AAGM 1 5/8” (41.3mm) mushroom head pushbutton and push-pull operator guard; Command/52 52AXGM 1 5/8” (41.3mm) mushroom head pushbutton and push-pull operator guard; BlackMax Locknut (Replacement Front Ring) 52AANP Non-illuminated pushbutton; Command/52 52AAXP Non-illuminated pushbutton; BlackMax 52AANL Momentary PB mushroom head and pilot light; Command/52 52AXNL Momentary PB mushroom head and pilot light; Black Max 52AANS Selector switch; Command/52 52AXNS Selector switch; BlackMax 52CANP Push-pull units, twist to release units and push to test illuminated PB; Command/52 52CXNP Push-pull units, twist to release units and push to test illuminated PB; BlackMax Padlock Attachments 52AALA Flush Pushbutton operators 52AALB Extended Pushbutton operators 52AALS Pushbuttons, selector switches, and non-illuminated mushroom head operators 52AALE Illuminated push-pull operators Hole Plugs 52AAH6 Corrosion resistant 52ABH6 Steel, gray 52ABHS Stainless steel Wrench and Grounding Kit 52MAWB Locknut wrench (all devices) 52AL109145 Grounding kit (all devices) 27 Selector Switch and Selector Pushbutton Configurations 1) 1. Determine which table to use based upon the type of selector (non-illuminated selector switch-top, illuminated selector switch-middle, and selector pushbutton-bottom). 2. Find the correct number of selector positions (2, 3 or 4 positions). 3. Select the contact operation required for each selector position. X indicates the contacts are closed, while O indicates the contacts are open. (For the selector pushbutton, N=normal and D=depressed). 4. Determine the CAM letter required for the chosen contact operation (only 1 CAM can be used per selector switch or selector pushbutton). 5. Contact blocks must be assembled in the position shown for each circuit application. The mounting position is viewed from the front of the device. 1) Number of Contact Block Limitations - CAM C and CAM G are limited to four contact blocks. - Selector operators in enclosures are limited to a depth of 1 contact block (2 blocks wide). Contact Block Mounting Example: Non-Illuminated Selector Switch Right Side This Side Up Selector Lever Front Left Side Max four contact blocks 28 Insert Non-Illuminated and Keyed Selector Switches Viewed from Front 2 Selector Positions Left Right X O O X 3 Selector Positions Left Center Right X O X O X X O O O X O X O O O X O X X O X O X O O O O X O O X X O O O X O O X O X O Left 4 Selector Positions Left Right Center Center Right X O O O O X O O O O O X O O X O Contact Block CAM Mounting Left NC (52BAJ) NO (52BAK) A A • • Contact Block CAM Mounting Left Right NO (52BAK) NO (52BAK) NC (52BAJ) NC (52BAJ) 2-NO (2-52BAK) NC (52BAJ) NO (52BAK) NC (52BAJ) NO (52BAK) NO (52BAK) NC (52BAJ) NC (52BAJ) NC (52BAJ) NO (52BAK) B B B B B C C D D E E G G G – • • •– – – Contact Block (s) CAM NO (52BAK) NC (52BAJ) NC (52BAJ) NO (52BAK) H H H H • • • • • • • • Right • • or or and or or or or or or • • • • • • • • or • • – – • Mounting Left • • Right – – – • • – Selector Switch and Selector Pushbutton Configurations 1) continued Configuration Examples Example 1: 3-Pos Maintained Selector Switch Required Contact Operation: Hand-Off-Auto Left Center Right X O O O O X CAM Selection: C Contact Block(s) and Position: 1NO-1NC (mounted either left or right) Resulting Catalog Number: 52SA2CABA0 (assumed chrome, white short lever, and mounted on left) Example 2: 3-Pos Illuminated Selector Switch Required Contact Operation: Left Center Right O X O O O X CAM Selection: B Contact Block(s) & Position: 2NO (mounted on right) Resulting Catalog Number: 52SA7BG5K4 (assumed chrome, 120V transformer, and blue) Illuminated and Keyed Selector Switches Viewed from Front 2 Selector Positions Left Right Contact Block CAM X O NC (52BAJ) NO (52BAK) A A 3 Selector Positions Left Center Right Contact Block CAM Mounting Left Right O O X O NC (52BAJ) NO (52BAK) NC (52BAJ) NO (52BAK) B B C C – – • • • • – – 2 Selector Positions Left Right N D N D Contact Block CAM X O O O X X O O O X O X O O O X X O O O O X X X X X X O X O X X O X O O O O O X 3 Selector Positions Left Center N D N D NC (52BAJ) NC (52BAJ) NO (52BAK) NO (52BAK) NC (52BAJ) NO (52BAK) NC (52BAJ) NC (52BAJ) NO (52BAK) NO (52BAK) Contact Block Right N D X X O O O O O O O X O X O O X O O X Mounting Left Right • • – – Selector Pushbuttons Viewed from Front X O X O O X O O O X O X Mounting Left Right • O O X X Q Q Q Q P P R R R R CAM •– •– •– • • • – – or or •– • •– • • – Mounting Left Right • NC (52BAJ) NC (52BAJ) NO (52BAK) NO (52BAK) S S S S – – •– • • – 29 Siemens Industry, Inc. Industry Automation Division 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-964-4114 [email protected] www.usa.siemens.com/power Subject to change without prior notice. Order No: PWCM-INSRT-1209 All rights reserved. Printed in USA © 2009 Siemens Industry, Inc. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.