FUS080 Catalog Specification Sheet

© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Transmitter SITRANS FUS080/FUE080
■ Overview
• SONOKIT (1-path or 2-path)
• FUS380 (2-path)
• FUE380 (2-path)
The transmitter FUS080 is always ordered as part of a complete
flowmeter system.
It can be manually ordered separately as spare part preprogrammed with the given sensor data.
■ Integration
The flowmeter pulse output is often used as input for an energy
meter or as input for digital systems for remote reading.
SITRANS FUS380 has two pulse outputs, with functions that can
be individually selected.
The settings of the transmitter, eg. flow and pulse output rate, are
defined when ordering the complete flowmeter.
SITRANS FUS080 is a transit time based transmitter designed
for ultrasonic flowmetering with any sensor in the FUS inline series SONOKIT, FUS380 and FUE380 up to DN 1200.
The ultrasonic flowmeter transmitter SITRANS FUS080 comes as
battery or mains powered version.The SITRANS FUS080 is designed to measure flow water applications.
If the flowmeter forms part of an energy meter system for custody transfer, no further approvals are needed, except eventually
local approvals on the flowmeter.
■ Technical specifications
Input
Measurement
The SONOKIT retrofit flowmeter series are shown from
page 3/275. The standard flowmeter series SITRANS FUS380 is
described from page 3/286. The type approved flowmeter series
for flowmetering in energy meter custody transfer systems are
named SITRANS FUE380 - see page 3/291.
Flow by measuring the transit
time difference of ultrasonic
signals through ultrasonic transducers in the sensor pipes.
Supporting of 1-path or 2-path
sensors in sizes DN 50 ... 1200
measuring on water.
Measuring rate
■ Benefits
• Battery-powered up to 6 years
• 115/230 V mains-powered with back-up battery option in case
of mains power failure
• Fast measuring frequency 15 Hz/0.5 Hz (230 V AC/Battery)
• Easy one button straight forward display
• IrDA optical interface for local communication
• 2-path measuring principle for optimum accuracy
• Compact or remote mounting
• Measures on all district water qualities and water conductivities
• No pressure drop
• Long-term stability
• 2 galvanic isolated digital outputs for easy connection to a calculator (potential free)
• Bidirectional measurement, with 2 totalizers and outputs
• Dynamic range Qi (min) : Qs (max) up to 1:400
■ Application
The main application for flowmeters with the transmitter
SITRANS FUS080 is measurement of water flow in district heating plants, local networks, boiler stations, substations, chiller
plants, irrigations plants and other general water applications.
■ Design
The transmitter type SITRANS FUS080 is designed with fiberglass reinforced polyamide enclosure for remote or compact installation in normal areas. The remote versions are available with
up to 30 meter distance from flowmeter to transmitter. When ordering as a compact version in the series FUS380 and FUE380
the transducer cables are pre-mounted at the sensor.
• Battery mode
0.5 Hz
• Mains supply
Up to 15 Hz
• Back-up mode
0.5 Hz (at mains supply drop)
Flow rate
0.02 ... 9 m/s (0.065 ... 29.5 ft/s),
bidirectional flow metering
Output
2 pulse or status outputs (A and
B), individual galvanically isolated
MOS relay outputs, passive
mode, max. 35 V AC/DC, max.
50 mA
Max. pulse frequency
100 Hz at Qs (Qmax)
Pulse value and length
Selectable with the ordering of the
flowmeter
Output A function
Pulse: forward, reverse, forward
net, reverse net (preset: forward)
Output B function
Pulse: forward, reverse, forward
net, reverse net (preset: forward)
or alarm indication or call-up indication (preset: alarm)
Pulse value A and B
0.1 l/p, 0.25 l/p, 0.5 l/p, 1 l/p,
2.5 l/p, 10 l/p, 25 l/p, 50 l/p,
100 l/p, 250 l/p, 500 l/p, 1 m3/p,
2.5 m3/p, 5 m3/p, 10 m3/p,
25 m3/p, 50 m3/p, 100 m3/p,
250 m3/p, 500 m3/p, 1 000 m3/p
Pulse length (depending on Qmax
by DN selection)
5, 10, 20, 50, 100, 200, 500 ms
(standard 5 ms)
Alarm indication
Path 1 (F1), path 2 (F2) internal,
failure (F3, F4), powers supply
warning or low battery indication
(F5), Qmax overflow (F6), pulse
overflow (F7, F8), internal data
logger warning (F9)
The transmitter is available in an IP67/NEMA 4X/6 enclosure and
is designed for use in the flowmeters series:
Siemens FI 01 · 2016
3/253
3
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Transmitter SITRANS FUS080/FUE080
Rated operation conditions
SONOKIT, FUS380, FUE380
Ambient conditions
The flow values and settings are predefined according to dimension selection.
Ambient temperature
• Operation
-10 ... +60 °C (14 ... 140 °F) (MID
version: max. +55 °C (131 °F))
• Storage
-40 ... +85 °C (-40 ... +185 °F)
(battery included)
Enclosure rating
3
IP67/NEMA 4X/6 to EN 60529 and
DIN 40050
Electromagnetic compatibility
• Emitted interference
To EN 55011/CISPR-11
• Immunity
To EN/IEC 61326-1 (Industry)
• MID approved (FUE380 series)
Environment class E2 and M1
Mechanical vibration
2 g, 1 ... 800 Hz sinusoidal in all
directions according to
IEC 68-2-6
Weight of transmitter
Approx. 1.5 kg (3.3 lb)
The transmitter settings are changeable by using the SW tool
PDM (for FUE380 series some of the setting are only readable,
restriction of the approval requirements).
Accuracy/Error in measurement:
(at reference conditions for FUS380 and FUE380 series,
SONOKIT series will differ in the accuracy)
• Pulse output
- 0.5 % of measured value at 0.5 ... 10 m/s or
- 0.25/V [m/s] % of measured value at flow < 0.5 m/s
• Repeatability 0.25 % of measured value at 0.5 ... 10 m/s
• Reference conditions
- Process temperature and ambient temperature: 25 °C 5 °C
(77 °F 9 °F)
- Transmitter warming-up time 30 min.
- Installation conditions of the sensor: Upstream section
> 10 x DN and downstream section > 5 DN
Design
Enclosure material
Fibre-glass reinforced polyamide, light gray color
Wall mounting kit
IP67/NEMA 4X/6 terminal box for
the wall mounting of the transmitter, fiber-glass reinforced polyamide with stainless steel bracket,
cable glands entries: 2 x 2 M20 or
PG 13.5 for power supply and
outputs and 2 x M20 or PG 13.5
for the sensor cables, glands
(supply and outputs and double
cable entries for sensor cables)
are included.
Sensor cable
Coaxial cable sets for remote
transmitter up to 30 m (98.4 ft)
long transducer cable, 75 
impedance, cables sets are prepared for the connection to the
sensors
Display and controls
Display
LCD, 8 digits, additional 2 digits
and symbols for status information
Resolution
Totalized information can be displayed with 1, 2 or 3 decimals or
automatic adjustment (default)
Display setting
Flow unit: Preset: m3/h
Volume unit: Preset: m3
Push button
One push button for menu selection and display information
Communication (IrDA optical eye)
IrDA – optical communication and
control interface with Modbus
RTU protocol for read or write
transmitter settings and data via
PC and PDM tool
Power supply
Battery
D-cell battery pack, 3.6 V LiSOCI
(Lithium Thionyl Chloride, 32 Ah),
replaceable, life- and workingtime up to 6 years
Mains
87 ... 265 V AC (50 ... 60 Hz) or
87 ... 265 V AC (50 ... 60 Hz) with
D-cell single battery backup,
2.6 V LiSOCI (Lithium Thionyl
Chloride, 12.5 Ah), replaceable,
life time up to 8 years
Power consumption
Mains version
3/254
Siemens FI 01 · 2016
Approx. 2.5 VA
[%]
5
4
3
2
Type accuracy limits FUS380
1
0
0 0.2 0.4 0.6 0.8 1
0 0.5 1
1.5
2
2
5
2.5
3
[m/s] 10
[ft/s] 33
8
[%]
5
4
FUE380 - admissible limits according
to OIML R 75 class 2
3
2
FUE380 - admissible limits according
to EN 1434 class 2
1
0
0 0.2 0.4 0.6 0.8 1
0 0.5 1
2
2
1.5
5
2.5
8
3
[m/s] 10
[ft/s] 33
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Transmitter SITRANS FUS080/FUE080
Output configuration
Sensor coaxial cable for SONOKIT series with FUS080
Coaxial cable
)RUZDUG
&XWRII
5HYHUVH
4
&XWRII
PR [s] =
Standard coaxial
cable (75 )
4
1
PF [Hz]
Outside diameter
Ø 5.8 mm
Length
15, 30 m (49.2, 98.4 ft)
between sensor and
transmitter
Material (outside
jacket)
Black PE
Ambient temperature
-10 ... +70 °C
(14 ... 158 °F)
Sensor coaxial cable for FUS380/FUE 380 series
PD[
Coaxial cable
PLQ
High temperature
coaxial cable (75 )
With special designed
glands for connection
in the sensor/transducer
Outside diameter
Ø 5.13 mm (first 0.3 m
(0.98 ft) part to the
transducer), Ø 5.8 mm
(for remaining cable to
the transmitter – black
holt melt junction part
between (Ø 16 mm,
length 70 mm)
Length
Up to 30 m (98.4 ft)
between sensor and
transmitter
Material (outside
jacket)
Brown PTFE (0.3 m
(9.84 ft) part) and black
PE (for remaining
cable)
Ambient temperature
-200 ... +200 °C
(-328 ... +392 °F)
(brown PTFE transducer part) and
-10 ... +70 °C
(14 ... 158 °F) (black PE
for remaining transmitter cable part)
3: DQGPV
35 SXOVHUDWH
3) SXOVHIUHTXHQF\
Pulse volume: output A/B configured as volume per pulse, calculated on forward/reverse or net forward/reverse flow. The volume per pulse is free scaleable (via PDM software).
Alarm output
On
Off
Error
Alarm status
No error
Pulse output B can be used as stated above or as alarm or callup function.
Call-up output
3
On
Off
Call-up reset
On
Call-up status
Off
Call-up: the call-up output is active until manually reset by use of
PDM tool. The call-up function is activated when an alarm is activated.
Siemens FI 01 · 2016
3/255
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Transmitter SITRANS FUS080/FUE080
■ Transmitter FUS080 operating instructions, accessories and spare parts
Spare part transmitter for FUE380 approved systems (7ME3410)
Operating instructions
3
Description
Article No.
for use with SONOKIT
• English
A5E03059912
integrated in FUS/FUE380
• English
• German
A5E00730100
A5E00740611
(only with MID approval marks, no MID verification – only a complete flowmeter can be MID-verified, i.e. sensor together with the
transmitter)
Description
This device is shipped with a Quick Start guide and a CD containing further SITRANS F US literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Accessories
Description
Article No.
Sun lid for FUS080 transmitter
(frame and lid)
A5E02328485
Article No.
FUE080 transmitter 3.6 V battery A5E02734600
(no battery included, to be
ordered separate) as spare part
transmitter for FUE380 flowmeter series. Transmitter Article
No. 7ME3450-0AA10-2AB0
FUE080 transmitter 3.6 V
battery (battery included) as
spare part transmitter for
FUE380 flowmeter serie.s1).
Transmitter Article No.
7ME3450-0AA20-2AB0
A5E02734568
FUE080 transmitter 230 V
A5E02734539
mains as spare part transmitter
for FUE380 flowmeter series.
Transmitter Article No.
7ME3450-0AA30-2AB0
Brace (holder) for optical IrDA
eye
A5E00695277
IrDA infrared interface adapter
with USB for data acquisition
with 1.2 m (3.9 ft) cable
FDK:087L4163
FUE080 transmitter 230 V
mains with backup-battery as
spare part transmitter for
FUE380 flowmeter series.
Transmitter Article No.
7ME3450-0AA40-2AB0
A5E02734585
When ordering: Inform on flowmeter Article No. and flowmeter serial
no. (e.g. 7ME3410-xxxxx-xxxx-Z, XX.... and xxxxxxHxxx)
Spare part transmitter for SONOKIT systems (7ME3210/7ME3220)
Process Device Manager SIMATIC PDM
Description
Article No.
SIMATIC PDM
Details about the SIMATIC PDM
tool can be found on page 8/9,
chapter "Communication and
Software"
FUS080 transmitter 3.6V battery
(no battery included, to be
ordered separate) as spare
part transmitter for SONOKIT
flowmeters. Transmitter Article
No. 7ME3450-0AA10-2AA0
A5E03048726
FUS080 transmitter 3.6V battery (battery included) as
spare part transmitter for
SONOKIT flowmeters1).
Transmitter Article No.
7ME3450-0AA20-2AA0
A5E03048714
See page 8/17,
chapter "Communication
and Software"
Spare parts
A spare part transmitter can be ordered for a specific system. In the
description of the following spare part transmitters the related transmitter Article No. found on the device silver front label is noted.
Spare part transmitter for FUS380 systems (7ME3400)
Article No.
Description
A5E02729700
FUS080 transmitter 3.6 V
battery (no battery included, to
be ordered separate) as spare
part transmitter for FUS380 flowmeter series. Transmitter Article
No. 7ME3450-0AA10-2AA0
FUS080 transmitter 3.6 V
A5E02729035
battery (battery included) as
spare part transmitter for FUS380
flowmeter series1).
Transmitter Article No.
7ME3450-0AA20-2AA0
FUS080 transmitter 230 V mains
as spare part transmitter for
FUS380 flowmeter series.
Transmitter Article No.
7ME3450-0AA30-2AA0
A5E02699309
FUS080 transmitter 230 V mains A5E02729610
with backup-battery as spare
part transmitter for FUS380 flowmeter series. Transmitter Article
No. 7ME3450-0AA40-2AA0
When ordering: Inform on flowmeter Article No. and flowmeter serial
no. (e.g. 7ME3400-xxxxx-xxxx-Z, XX.... and xxxxxxHxxx)
3/256
Siemens FI 01 · 2016
A5E03048701
FUS080 transmitter 230V
mains as spare part transmitter
for SONOKIT flowmeters.
Transmitter Article No.
7ME3450-0AA30-2AA0
FUS080 transmitter 230V
mains with backup-battery as
spare part transmitter for
SONOKIT flowmeters.
Transmitter Article No.
7ME3450-0AA40-2AA0
A5E03048719
When ordering: Inform on flowmeter Article No. and flowmeter serial
no. (e.g. 7ME3220-xxxxx-xxxx-Z, XX.... and xxxxxxHxxx)
1)
Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and
UN 3091". Special transport documentation is required to observe these
regulations. This may influence both transport time and costs.
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Transmitter SITRANS FUS080/FUE080
Spare part transmitter for FUS880 retrofitting systems (7ME3440)
Description
Article No.
Sparepart FUS080
A5E03412669
transmitter 3.6 V, incl. 3.6V
dual batterie pack, USA version
Transmitter Article No.:
7ME3450-0AA20-1CA0:
Label, 0:
Siemens FUS080 transmitter;
Version, 0:
Without connection box;
Enclosure, A:
IP67/NEMA 4X/6;
Code A: Standard;
Supply Voltage, 2:
3.6V DC battery;
Ex. Approval, 0:
no Ex approval;
Display, 1:
With display and unit label;
Region version, C: USA:
AcFt,CFS;
Application, A:
Standard FUS080 (for
SITRANS Retrofit - 7ME344);
Code, 0: Standard
FUS080 transmitter for
FUS880 retrofit systems,
USA version,
incl. wall-mounting kit, 2
transducers and 2 pcs. 60 ft
(20 m) of cables.
Label, 0:
Siemens FUS080 transmitter;
Diameter, 0A: None;
Wall Thickness, A: None;
Pipe Material, 0: No Pipe;
Track configuration, 1:
1-Track;
Region version, 2: USA:
AcFt,CFS;
Transmitter, D: FUS080,IP67,
Battery, Remote, unit label;
Template, A: None;
Transducer coax cable,
4: 20 m with gland
7ME34400AA01-2DA4
FUS080 transmitter for
7ME3440FUS880 retrofit systems,
0AA03-2DA4
USA version,
incl. wall-mounting kit, 4
transducers and 4 pcs. 60 ft
(20 m) of cables:
Label, 0:
Siemens FUS080 transmitter;
Diameter, 0A: None;
Wall Thickness, A: None;
Pipe Material, 0: No Pipe;
Track configuration, 3:
2-Track (X-Configuration);
Region version, 2: USA:
AcFt,CFS;
Transmitter, D: FUS080 ,IP67,
Battery, Remote,unit label;
Template, A: None;
Transducer coax cable, 4:
20 m with gland
Description
Article No.
Internal battery pack, one set
of 2 D-cell (3.6 V 33 Ah)1)
• 1 pc. pack
A5E02679676
• 24 pcs. pack
A5E02896941
Single battery back-up to main A5E02679923
supply (13.5 Ah)1)
3
Battery cover for transmitter
FUS080
A5E00694468
PG 13.5 cable gland set for
FUS080 power and output
connection, black PA plastic,
2 pcs.
• cables Ø 6 ... 12 mm
(0.24" ... 0.47")
• -40 ... +100 °C
(-40 ... +212 °F)
FDK:083G0228
PG 13.5 cable gland set
A5E00694500
(two cable entries) for FUS080
sensor connection, black PA
plastic, 2 pcs.
• cables Ø 6 ... 12 mm
(0.24" ... 0.47")
• -40 ... +100 °C
(-40 ... +212 °F)
SITRANS FUS/FUE380 wall
A5E00694509
mounting kit for remote transmitter mounting, including connection plate
(DN 50 ... DN 1200/2" ... 48")
SITRANS FUS/FUE380 termi- A5E01208138
nal box for compact transmitter
mounting, including connection plate, (bronze sensors
only, DN 50 ... DN 80/2" ... 3")
SITRANS FUS/FUE380 termi- A5E00694660
nal box for compact transmitter
mounting, including connection plate, (steel sensors only,
DN 100 ... DN 1200/4" ... 48")
FUS080 display and keypad
with Siemens logo
1)
A5E00873496
Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and
UN 3091". Special transport documentation is required to observe these
regulations. This may influence both transport time and costs.
Downloads for DEVICE description FUE380
http://support.automation.siemens.com/WW/view/en/23036121/133100
Siemens FI 01 · 2016
3/257
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Transmitter SITRANS FUS080/FUE080
Sensor cables for FUS380/FUE380 flowmeters
Article No.
Description
DN 50 to 80 flowmeters
Coaxial cable for FUS080;
with 0.3 m brown PTFE high
temp. transducer part,
max. 200 °C (392 °F) and
black PVC for remaining transmitter part, max. 70 °C
(158 °F); impedance 75 
3
5 m (16.4 ft) cable set (4 pcs.) A5E01208092
for DN 50 ... DN 80 (2" ... 3")
remote mounting
10 m (32.8 ft) cable set
(4 pcs.) for DN 50 ... DN 80
(2" ... 3") remote mounting
A5E01208114
20 m (65.6 ft) cable set
(4 pcs.) for DN 50 ... DN 80
(2" ... 3") remote mounting
A5E01208117
30 m (98.4 ft) cable set
(4 pcs.) for DN 50 ... DN 80
(2" ... 3") remote mounting
A5E01208121
0.5 m (1.64 ft) cable set
(4 pcs.) for DN 50 ... DN 80
(2" ... 3") for compact version
of FUS380/FUE380
A5E01208126
DN 100 to 1200 flowmeters
Coaxial cable for FUS080;
with 0.3 m brown PTFE high
temp. transducer part,
max. 200 °C (392 °F) and
black PVC for remaining transmitter part, max. 70 °C
(158 °F); impedance 75 
5 m (16.4 ft) cable set (4 pcs.) A5E00695476
for DN 100 ... DN 1200
(4" ... 48") remote mounting
10 m (32.8 ft) cable set
A5E00695479
(4 pcs.) for DN 100 ... DN 1200
(4" ... 48") remote mounting
20 m (65.6 ft) cable set
A5E00695480
(4 pcs.) for DN 100 ... DN 1200
(4" ... 48") remote mounting
30 m (98.4 ft) cable set
A5E00695483
(4 pcs.) for DN 100 ... DN 1200
(4" ... 48") remote mounting
1 m (3.28 ft) cable set
A5E00695486
(4 pcs.) for DN 100 ... DN 1200
(4" ... 48") for compact version
of FUS380/FUE380
Sensor cables for SONOKIT flowmeter with FUS080
Description
Article No.
15 m (49.2 ft) cable set
(2 pcs.) remote mounting with
SONOKIT flowmeters
A5E02478541
30 m (98.4 ft) cable set
(2 pcs.) remote mounting with
SONOKIT flowmeters
A5E02478751
3/258
Siemens FI 01 · 2016
Sensor cables for FUS880 retrofitting systems (7ME3440)
Description
Article No.
Coaxial cable with transducer connection
for use in FUS880 and
SONO 3300 sensors; with
0.3 m brown PTFE high temperature transducer part, max.
200 °C (392 °F) and black PVC
for the remaining transmitter
part, max. 70 °C (158 ºF);
cable impedance 75 .
• 1 x 10 m (32.8 ft)
FDK:085L2400
• 1 x 20 m (65.6 ft)
FDK:085L2401
• 1 x 30 m (98.4 ft)
FDK:085L2402
Transducer spare part set of FDK:087H3007
two transducers with gaskets for STRANS FUS880
retrofitting systems
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Transmitter SITRANS FUS080/FUE080
■ Dimensional drawings
FUS080 transmitter IP67/NEMA 4X/6, wall mounting and compact mounting
71 (2.8)
6 (0.24)
8.5 (0.34)
25
(0.98)
13 (0.5)
178 (7.01)
Ø8 (0.3)
131 (5.16)
102 (4.02)
Ø12 (0.5)
240 (9.45)
71 (2.8)
Ø8 (0.3)
155 (6.10)
13 (0.5)
155 (6.10)
190 (7.45)
170 (6.69)
Transmitter wall mounted, dimensions in mm (inch)
Transmitter compact mounted, dimensions in mm (inch)
■ Schematics
Internal connection
Top of connection Board
External connection
Connection Variant
Positive logic
Passive output
Open drain
Output A
V
0V
I < 50 mA
Shield
V ≤ 35 V DC
Signal
R
Output B
Negative logic
V
0V
I < 50 mA
V ≤ 35 V DC
R
Signal
Electrical connection of SITRANS FUS080
Siemens FI 01 · 2016
3/259
3