© Siemens AG 2016 Flow Measurement SITRANS F US Inline Transmitter SITRANS FUS080/FUE080 ■ Overview • SONOKIT (1-path or 2-path) • FUS380 (2-path) • FUE380 (2-path) The transmitter FUS080 is always ordered as part of a complete flowmeter system. It can be manually ordered separately as spare part preprogrammed with the given sensor data. ■ Integration The flowmeter pulse output is often used as input for an energy meter or as input for digital systems for remote reading. SITRANS FUS380 has two pulse outputs, with functions that can be individually selected. The settings of the transmitter, eg. flow and pulse output rate, are defined when ordering the complete flowmeter. SITRANS FUS080 is a transit time based transmitter designed for ultrasonic flowmetering with any sensor in the FUS inline series SONOKIT, FUS380 and FUE380 up to DN 1200. The ultrasonic flowmeter transmitter SITRANS FUS080 comes as battery or mains powered version.The SITRANS FUS080 is designed to measure flow water applications. If the flowmeter forms part of an energy meter system for custody transfer, no further approvals are needed, except eventually local approvals on the flowmeter. ■ Technical specifications Input Measurement The SONOKIT retrofit flowmeter series are shown from page 3/275. The standard flowmeter series SITRANS FUS380 is described from page 3/286. The type approved flowmeter series for flowmetering in energy meter custody transfer systems are named SITRANS FUE380 - see page 3/291. Flow by measuring the transit time difference of ultrasonic signals through ultrasonic transducers in the sensor pipes. Supporting of 1-path or 2-path sensors in sizes DN 50 ... 1200 measuring on water. Measuring rate ■ Benefits • Battery-powered up to 6 years • 115/230 V mains-powered with back-up battery option in case of mains power failure • Fast measuring frequency 15 Hz/0.5 Hz (230 V AC/Battery) • Easy one button straight forward display • IrDA optical interface for local communication • 2-path measuring principle for optimum accuracy • Compact or remote mounting • Measures on all district water qualities and water conductivities • No pressure drop • Long-term stability • 2 galvanic isolated digital outputs for easy connection to a calculator (potential free) • Bidirectional measurement, with 2 totalizers and outputs • Dynamic range Qi (min) : Qs (max) up to 1:400 ■ Application The main application for flowmeters with the transmitter SITRANS FUS080 is measurement of water flow in district heating plants, local networks, boiler stations, substations, chiller plants, irrigations plants and other general water applications. ■ Design The transmitter type SITRANS FUS080 is designed with fiberglass reinforced polyamide enclosure for remote or compact installation in normal areas. The remote versions are available with up to 30 meter distance from flowmeter to transmitter. When ordering as a compact version in the series FUS380 and FUE380 the transducer cables are pre-mounted at the sensor. • Battery mode 0.5 Hz • Mains supply Up to 15 Hz • Back-up mode 0.5 Hz (at mains supply drop) Flow rate 0.02 ... 9 m/s (0.065 ... 29.5 ft/s), bidirectional flow metering Output 2 pulse or status outputs (A and B), individual galvanically isolated MOS relay outputs, passive mode, max. 35 V AC/DC, max. 50 mA Max. pulse frequency 100 Hz at Qs (Qmax) Pulse value and length Selectable with the ordering of the flowmeter Output A function Pulse: forward, reverse, forward net, reverse net (preset: forward) Output B function Pulse: forward, reverse, forward net, reverse net (preset: forward) or alarm indication or call-up indication (preset: alarm) Pulse value A and B 0.1 l/p, 0.25 l/p, 0.5 l/p, 1 l/p, 2.5 l/p, 10 l/p, 25 l/p, 50 l/p, 100 l/p, 250 l/p, 500 l/p, 1 m3/p, 2.5 m3/p, 5 m3/p, 10 m3/p, 25 m3/p, 50 m3/p, 100 m3/p, 250 m3/p, 500 m3/p, 1 000 m3/p Pulse length (depending on Qmax by DN selection) 5, 10, 20, 50, 100, 200, 500 ms (standard 5 ms) Alarm indication Path 1 (F1), path 2 (F2) internal, failure (F3, F4), powers supply warning or low battery indication (F5), Qmax overflow (F6), pulse overflow (F7, F8), internal data logger warning (F9) The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: Siemens FI 01 · 2016 3/253 3 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Transmitter SITRANS FUS080/FUE080 Rated operation conditions SONOKIT, FUS380, FUE380 Ambient conditions The flow values and settings are predefined according to dimension selection. Ambient temperature • Operation -10 ... +60 °C (14 ... 140 °F) (MID version: max. +55 °C (131 °F)) • Storage -40 ... +85 °C (-40 ... +185 °F) (battery included) Enclosure rating 3 IP67/NEMA 4X/6 to EN 60529 and DIN 40050 Electromagnetic compatibility • Emitted interference To EN 55011/CISPR-11 • Immunity To EN/IEC 61326-1 (Industry) • MID approved (FUE380 series) Environment class E2 and M1 Mechanical vibration 2 g, 1 ... 800 Hz sinusoidal in all directions according to IEC 68-2-6 Weight of transmitter Approx. 1.5 kg (3.3 lb) The transmitter settings are changeable by using the SW tool PDM (for FUE380 series some of the setting are only readable, restriction of the approval requirements). Accuracy/Error in measurement: (at reference conditions for FUS380 and FUE380 series, SONOKIT series will differ in the accuracy) • Pulse output - 0.5 % of measured value at 0.5 ... 10 m/s or - 0.25/V [m/s] % of measured value at flow < 0.5 m/s • Repeatability 0.25 % of measured value at 0.5 ... 10 m/s • Reference conditions - Process temperature and ambient temperature: 25 °C 5 °C (77 °F 9 °F) - Transmitter warming-up time 30 min. - Installation conditions of the sensor: Upstream section > 10 x DN and downstream section > 5 DN Design Enclosure material Fibre-glass reinforced polyamide, light gray color Wall mounting kit IP67/NEMA 4X/6 terminal box for the wall mounting of the transmitter, fiber-glass reinforced polyamide with stainless steel bracket, cable glands entries: 2 x 2 M20 or PG 13.5 for power supply and outputs and 2 x M20 or PG 13.5 for the sensor cables, glands (supply and outputs and double cable entries for sensor cables) are included. Sensor cable Coaxial cable sets for remote transmitter up to 30 m (98.4 ft) long transducer cable, 75 impedance, cables sets are prepared for the connection to the sensors Display and controls Display LCD, 8 digits, additional 2 digits and symbols for status information Resolution Totalized information can be displayed with 1, 2 or 3 decimals or automatic adjustment (default) Display setting Flow unit: Preset: m3/h Volume unit: Preset: m3 Push button One push button for menu selection and display information Communication (IrDA optical eye) IrDA – optical communication and control interface with Modbus RTU protocol for read or write transmitter settings and data via PC and PDM tool Power supply Battery D-cell battery pack, 3.6 V LiSOCI (Lithium Thionyl Chloride, 32 Ah), replaceable, life- and workingtime up to 6 years Mains 87 ... 265 V AC (50 ... 60 Hz) or 87 ... 265 V AC (50 ... 60 Hz) with D-cell single battery backup, 2.6 V LiSOCI (Lithium Thionyl Chloride, 12.5 Ah), replaceable, life time up to 8 years Power consumption Mains version 3/254 Siemens FI 01 · 2016 Approx. 2.5 VA [%] 5 4 3 2 Type accuracy limits FUS380 1 0 0 0.2 0.4 0.6 0.8 1 0 0.5 1 1.5 2 2 5 2.5 3 [m/s] 10 [ft/s] 33 8 [%] 5 4 FUE380 - admissible limits according to OIML R 75 class 2 3 2 FUE380 - admissible limits according to EN 1434 class 2 1 0 0 0.2 0.4 0.6 0.8 1 0 0.5 1 2 2 1.5 5 2.5 8 3 [m/s] 10 [ft/s] 33 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Transmitter SITRANS FUS080/FUE080 Output configuration Sensor coaxial cable for SONOKIT series with FUS080 Coaxial cable )RUZDUG &XWRII 5HYHUVH 4 &XWRII PR [s] = Standard coaxial cable (75 ) 4 1 PF [Hz] Outside diameter Ø 5.8 mm Length 15, 30 m (49.2, 98.4 ft) between sensor and transmitter Material (outside jacket) Black PE Ambient temperature -10 ... +70 °C (14 ... 158 °F) Sensor coaxial cable for FUS380/FUE 380 series PD[ Coaxial cable PLQ High temperature coaxial cable (75 ) With special designed glands for connection in the sensor/transducer Outside diameter Ø 5.13 mm (first 0.3 m (0.98 ft) part to the transducer), Ø 5.8 mm (for remaining cable to the transmitter – black holt melt junction part between (Ø 16 mm, length 70 mm) Length Up to 30 m (98.4 ft) between sensor and transmitter Material (outside jacket) Brown PTFE (0.3 m (9.84 ft) part) and black PE (for remaining cable) Ambient temperature -200 ... +200 °C (-328 ... +392 °F) (brown PTFE transducer part) and -10 ... +70 °C (14 ... 158 °F) (black PE for remaining transmitter cable part) 3: DQGPV 35 SXOVHUDWH 3) SXOVHIUHTXHQF\ Pulse volume: output A/B configured as volume per pulse, calculated on forward/reverse or net forward/reverse flow. The volume per pulse is free scaleable (via PDM software). Alarm output On Off Error Alarm status No error Pulse output B can be used as stated above or as alarm or callup function. Call-up output 3 On Off Call-up reset On Call-up status Off Call-up: the call-up output is active until manually reset by use of PDM tool. The call-up function is activated when an alarm is activated. Siemens FI 01 · 2016 3/255 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Transmitter SITRANS FUS080/FUE080 ■ Transmitter FUS080 operating instructions, accessories and spare parts Spare part transmitter for FUE380 approved systems (7ME3410) Operating instructions 3 Description Article No. for use with SONOKIT • English A5E03059912 integrated in FUS/FUE380 • English • German A5E00730100 A5E00740611 (only with MID approval marks, no MID verification – only a complete flowmeter can be MID-verified, i.e. sensor together with the transmitter) Description This device is shipped with a Quick Start guide and a CD containing further SITRANS F US literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Accessories Description Article No. Sun lid for FUS080 transmitter (frame and lid) A5E02328485 Article No. FUE080 transmitter 3.6 V battery A5E02734600 (no battery included, to be ordered separate) as spare part transmitter for FUE380 flowmeter series. Transmitter Article No. 7ME3450-0AA10-2AB0 FUE080 transmitter 3.6 V battery (battery included) as spare part transmitter for FUE380 flowmeter serie.s1). Transmitter Article No. 7ME3450-0AA20-2AB0 A5E02734568 FUE080 transmitter 230 V A5E02734539 mains as spare part transmitter for FUE380 flowmeter series. Transmitter Article No. 7ME3450-0AA30-2AB0 Brace (holder) for optical IrDA eye A5E00695277 IrDA infrared interface adapter with USB for data acquisition with 1.2 m (3.9 ft) cable FDK:087L4163 FUE080 transmitter 230 V mains with backup-battery as spare part transmitter for FUE380 flowmeter series. Transmitter Article No. 7ME3450-0AA40-2AB0 A5E02734585 When ordering: Inform on flowmeter Article No. and flowmeter serial no. (e.g. 7ME3410-xxxxx-xxxx-Z, XX.... and xxxxxxHxxx) Spare part transmitter for SONOKIT systems (7ME3210/7ME3220) Process Device Manager SIMATIC PDM Description Article No. SIMATIC PDM Details about the SIMATIC PDM tool can be found on page 8/9, chapter "Communication and Software" FUS080 transmitter 3.6V battery (no battery included, to be ordered separate) as spare part transmitter for SONOKIT flowmeters. Transmitter Article No. 7ME3450-0AA10-2AA0 A5E03048726 FUS080 transmitter 3.6V battery (battery included) as spare part transmitter for SONOKIT flowmeters1). Transmitter Article No. 7ME3450-0AA20-2AA0 A5E03048714 See page 8/17, chapter "Communication and Software" Spare parts A spare part transmitter can be ordered for a specific system. In the description of the following spare part transmitters the related transmitter Article No. found on the device silver front label is noted. Spare part transmitter for FUS380 systems (7ME3400) Article No. Description A5E02729700 FUS080 transmitter 3.6 V battery (no battery included, to be ordered separate) as spare part transmitter for FUS380 flowmeter series. Transmitter Article No. 7ME3450-0AA10-2AA0 FUS080 transmitter 3.6 V A5E02729035 battery (battery included) as spare part transmitter for FUS380 flowmeter series1). Transmitter Article No. 7ME3450-0AA20-2AA0 FUS080 transmitter 230 V mains as spare part transmitter for FUS380 flowmeter series. Transmitter Article No. 7ME3450-0AA30-2AA0 A5E02699309 FUS080 transmitter 230 V mains A5E02729610 with backup-battery as spare part transmitter for FUS380 flowmeter series. Transmitter Article No. 7ME3450-0AA40-2AA0 When ordering: Inform on flowmeter Article No. and flowmeter serial no. (e.g. 7ME3400-xxxxx-xxxx-Z, XX.... and xxxxxxHxxx) 3/256 Siemens FI 01 · 2016 A5E03048701 FUS080 transmitter 230V mains as spare part transmitter for SONOKIT flowmeters. Transmitter Article No. 7ME3450-0AA30-2AA0 FUS080 transmitter 230V mains with backup-battery as spare part transmitter for SONOKIT flowmeters. Transmitter Article No. 7ME3450-0AA40-2AA0 A5E03048719 When ordering: Inform on flowmeter Article No. and flowmeter serial no. (e.g. 7ME3220-xxxxx-xxxx-Z, XX.... and xxxxxxHxxx) 1) Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and UN 3091". Special transport documentation is required to observe these regulations. This may influence both transport time and costs. © Siemens AG 2016 Flow Measurement SITRANS F US Inline Transmitter SITRANS FUS080/FUE080 Spare part transmitter for FUS880 retrofitting systems (7ME3440) Description Article No. Sparepart FUS080 A5E03412669 transmitter 3.6 V, incl. 3.6V dual batterie pack, USA version Transmitter Article No.: 7ME3450-0AA20-1CA0: Label, 0: Siemens FUS080 transmitter; Version, 0: Without connection box; Enclosure, A: IP67/NEMA 4X/6; Code A: Standard; Supply Voltage, 2: 3.6V DC battery; Ex. Approval, 0: no Ex approval; Display, 1: With display and unit label; Region version, C: USA: AcFt,CFS; Application, A: Standard FUS080 (for SITRANS Retrofit - 7ME344); Code, 0: Standard FUS080 transmitter for FUS880 retrofit systems, USA version, incl. wall-mounting kit, 2 transducers and 2 pcs. 60 ft (20 m) of cables. Label, 0: Siemens FUS080 transmitter; Diameter, 0A: None; Wall Thickness, A: None; Pipe Material, 0: No Pipe; Track configuration, 1: 1-Track; Region version, 2: USA: AcFt,CFS; Transmitter, D: FUS080,IP67, Battery, Remote, unit label; Template, A: None; Transducer coax cable, 4: 20 m with gland 7ME34400AA01-2DA4 FUS080 transmitter for 7ME3440FUS880 retrofit systems, 0AA03-2DA4 USA version, incl. wall-mounting kit, 4 transducers and 4 pcs. 60 ft (20 m) of cables: Label, 0: Siemens FUS080 transmitter; Diameter, 0A: None; Wall Thickness, A: None; Pipe Material, 0: No Pipe; Track configuration, 3: 2-Track (X-Configuration); Region version, 2: USA: AcFt,CFS; Transmitter, D: FUS080 ,IP67, Battery, Remote,unit label; Template, A: None; Transducer coax cable, 4: 20 m with gland Description Article No. Internal battery pack, one set of 2 D-cell (3.6 V 33 Ah)1) • 1 pc. pack A5E02679676 • 24 pcs. pack A5E02896941 Single battery back-up to main A5E02679923 supply (13.5 Ah)1) 3 Battery cover for transmitter FUS080 A5E00694468 PG 13.5 cable gland set for FUS080 power and output connection, black PA plastic, 2 pcs. • cables Ø 6 ... 12 mm (0.24" ... 0.47") • -40 ... +100 °C (-40 ... +212 °F) FDK:083G0228 PG 13.5 cable gland set A5E00694500 (two cable entries) for FUS080 sensor connection, black PA plastic, 2 pcs. • cables Ø 6 ... 12 mm (0.24" ... 0.47") • -40 ... +100 °C (-40 ... +212 °F) SITRANS FUS/FUE380 wall A5E00694509 mounting kit for remote transmitter mounting, including connection plate (DN 50 ... DN 1200/2" ... 48") SITRANS FUS/FUE380 termi- A5E01208138 nal box for compact transmitter mounting, including connection plate, (bronze sensors only, DN 50 ... DN 80/2" ... 3") SITRANS FUS/FUE380 termi- A5E00694660 nal box for compact transmitter mounting, including connection plate, (steel sensors only, DN 100 ... DN 1200/4" ... 48") FUS080 display and keypad with Siemens logo 1) A5E00873496 Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and UN 3091". Special transport documentation is required to observe these regulations. This may influence both transport time and costs. Downloads for DEVICE description FUE380 http://support.automation.siemens.com/WW/view/en/23036121/133100 Siemens FI 01 · 2016 3/257 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Transmitter SITRANS FUS080/FUE080 Sensor cables for FUS380/FUE380 flowmeters Article No. Description DN 50 to 80 flowmeters Coaxial cable for FUS080; with 0.3 m brown PTFE high temp. transducer part, max. 200 °C (392 °F) and black PVC for remaining transmitter part, max. 70 °C (158 °F); impedance 75 3 5 m (16.4 ft) cable set (4 pcs.) A5E01208092 for DN 50 ... DN 80 (2" ... 3") remote mounting 10 m (32.8 ft) cable set (4 pcs.) for DN 50 ... DN 80 (2" ... 3") remote mounting A5E01208114 20 m (65.6 ft) cable set (4 pcs.) for DN 50 ... DN 80 (2" ... 3") remote mounting A5E01208117 30 m (98.4 ft) cable set (4 pcs.) for DN 50 ... DN 80 (2" ... 3") remote mounting A5E01208121 0.5 m (1.64 ft) cable set (4 pcs.) for DN 50 ... DN 80 (2" ... 3") for compact version of FUS380/FUE380 A5E01208126 DN 100 to 1200 flowmeters Coaxial cable for FUS080; with 0.3 m brown PTFE high temp. transducer part, max. 200 °C (392 °F) and black PVC for remaining transmitter part, max. 70 °C (158 °F); impedance 75 5 m (16.4 ft) cable set (4 pcs.) A5E00695476 for DN 100 ... DN 1200 (4" ... 48") remote mounting 10 m (32.8 ft) cable set A5E00695479 (4 pcs.) for DN 100 ... DN 1200 (4" ... 48") remote mounting 20 m (65.6 ft) cable set A5E00695480 (4 pcs.) for DN 100 ... DN 1200 (4" ... 48") remote mounting 30 m (98.4 ft) cable set A5E00695483 (4 pcs.) for DN 100 ... DN 1200 (4" ... 48") remote mounting 1 m (3.28 ft) cable set A5E00695486 (4 pcs.) for DN 100 ... DN 1200 (4" ... 48") for compact version of FUS380/FUE380 Sensor cables for SONOKIT flowmeter with FUS080 Description Article No. 15 m (49.2 ft) cable set (2 pcs.) remote mounting with SONOKIT flowmeters A5E02478541 30 m (98.4 ft) cable set (2 pcs.) remote mounting with SONOKIT flowmeters A5E02478751 3/258 Siemens FI 01 · 2016 Sensor cables for FUS880 retrofitting systems (7ME3440) Description Article No. Coaxial cable with transducer connection for use in FUS880 and SONO 3300 sensors; with 0.3 m brown PTFE high temperature transducer part, max. 200 °C (392 °F) and black PVC for the remaining transmitter part, max. 70 °C (158 ºF); cable impedance 75 . • 1 x 10 m (32.8 ft) FDK:085L2400 • 1 x 20 m (65.6 ft) FDK:085L2401 • 1 x 30 m (98.4 ft) FDK:085L2402 Transducer spare part set of FDK:087H3007 two transducers with gaskets for STRANS FUS880 retrofitting systems © Siemens AG 2016 Flow Measurement SITRANS F US Inline Transmitter SITRANS FUS080/FUE080 ■ Dimensional drawings FUS080 transmitter IP67/NEMA 4X/6, wall mounting and compact mounting 71 (2.8) 6 (0.24) 8.5 (0.34) 25 (0.98) 13 (0.5) 178 (7.01) Ø8 (0.3) 131 (5.16) 102 (4.02) Ø12 (0.5) 240 (9.45) 71 (2.8) Ø8 (0.3) 155 (6.10) 13 (0.5) 155 (6.10) 190 (7.45) 170 (6.69) Transmitter wall mounted, dimensions in mm (inch) Transmitter compact mounted, dimensions in mm (inch) ■ Schematics Internal connection Top of connection Board External connection Connection Variant Positive logic Passive output Open drain Output A V 0V I < 50 mA Shield V ≤ 35 V DC Signal R Output B Negative logic V 0V I < 50 mA V ≤ 35 V DC R Signal Electrical connection of SITRANS FUS080 Siemens FI 01 · 2016 3/259 3