© Siemens AG 2016 Flow Measurement SITRANS F US Inline Flowmeter SONOKIT (with FUS060 or FUS080) ■ Overview ■ Design The SONOKIT package box contains all necessary parts to build an ultrasonic flowmeter on existing pipes depending on choices at ordering: • Papers to wrap around pipes for alignment of sensors • Transducer alignment tools • Mounting plates, transducer holders and SONO 3200 transducers • Transducer cables • SITRANS FUS060 or FUS080 transmitter for wall mounting • 4-path version (up to DN 1500 (60")) is available on special request (PVR) ■ Technical specifications SONOKIT is a transit time based ultrasonic flowmeter for retrofitting on existing pipelines. The transmitter related to this system is the SITRANS FUS080 or FUS060. Technical specifications to the FUS060 see page 3/247 and to FUS080 see page 3/253. Accuracy • 2-path: (0.5 … 1.5 %) • 1-path: (1 … 3 %) The kit offers all necessary parts and special tools to make the installation as 1-path or 2-path flowmeter. Typical, depending on accuracy of measurements of installation The set is made for installation on empty pipes or pipes under pressure without process shut-down (hot-tap). Note: Accuracy depends on the accuracy of the measurements taken at location. This means that inaccurate measurements of angles, distance between transducers, wall thickness and pipe diameter have a direct effect on the accuracy. Values measured are entered into the memory of the FUS060 or FUS080 transmitter. Please contact Siemens for further information on hot-tap tools and instructions. SONOKIT has inline transducers (in contact with media) which assure superior accuracy and performance. ■ Benefits • Cost-effective solution – contains all the necessary components for retrofitting • SONOKIT is easy to install in pipeline sizes DN 200 to DN 3000 (8" to 120") 1-path DN 100 to DN 2400 (4" to 96"). • No bypass installation necessary – withstands pressures up to 40 bar (580 psi) and media temperatures between -20 °C and +200 °C (-4 °F and +392 °F) • High accuracy – the bigger the pipe, the more accurate the result • Solid construction and no moving parts for a 100 % maintenance and obstruction-free flowmeter • The SONOKIT comes with transducers in IP68 enclosure • Available in a robust version that can be buried and withstands constant flooding • Inline transducers assure superior accuracy and performance • Automatic calculation of the calibration factor when pipe geometry data are entered in the transmitter • FUS060 transmitter versions with HART or PROFIBUS PA • FUS080 transmitter, battery or mains-powered Requirements for pipes Size FUS060: DN 100 … DN 3000 (4" … 120") FUS080: DN 100 … DN 1200 (4" … 48") Line pressure max. 40 bar (580 psi) Media temperature • Standard -10 ... +200 °C (14 ... 392 °F) • ATEX Ex d version -20 .... +200 °C (-4 … +392 °F) • ATEX Ex i version -10 ... +200 °C (+14 ... +392 °F) • Specials -200 °C (-328 °F) or up to 250 °C (482 °F) Ambient temperature sensor • Standard and Ex-i version -20 ... +60 °C (-4 ... +140 °F) • Ex d version -20 ... +180 °C (-4 ... +356 °F) Transducer enclosure/ approvals/certificates Standard version IP67 (NEMA 6)/IP68 (NEMA 6P) Ex approval System ATEX approval for SONO 3200 Ex i transducers together with transmitter FUS060-Ex: ATEX II 2 G Ex dem [ia/ib] IIC T6/T4/T3 Gb or ATEX II 2G Ex d IIC T3-T6 Gb with SONO 3200 Ex d transducers (for standard FUS060 transmitter, installed outside of Ex zone) Material certificates EN 10204-3.1 material certificate on transducer mounting parts ■ Application • • • • • • • • • Raw water intake for water treatment plants Water distribution systems Irrigation systems Power generation (energy and water) District heating plants Cooling water plants within the industry and in power stations Systems within the oil and refinery business Sewage treatment plants Plants transporting non-conductive liquids Transducer materials Terminal housing Standard version: PA 6.6, 100 °C (212 °F) or stainless steel AISI 316, 200 °C (392 °F) Transducer body Standard version: Stainless steel AISI 316, 200 °C (392 °F) Siemens FI 01 · 2016 3/275 3 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Flowmeter SONOKIT (with FUS060 or FUS080) Materials of existing pipeline Steel Transducer holder: EN 10273 or EN 10216 (P235GH) Mounting plates1): EN 10273 or EN 10216 (P235GH) Transducer holder: Stainless steel AISI 316 or similar Dimension of the package box (L x W x H, approx.) 856 x 390 x 344 mm (33.7" x 15.4" x 13.5") Weight example of a package (standard 2-path with FUS060) approx. 53 kg (116.8 lb) Certificates and approvals Conformity certificate The devices are supplied as standard with a Siemens Certificate of Conformity on a CD Material certificate Mounting plates1): Stainless steel AISI 316 or similar Material certificate for the transducer parts according to EN 10204-3.1 is optionally available Approvals No custody transfer approvals Steel pipe (AISI 316 and St. 37.2 or corresponding material) Transducer and holder available in length L = 160, allowing a pipe wall thickness up to 20 mm (0.79") Information on PED approval: The SONOKIT includes the pipe mounting parts only and therefore it cannot be PED-approved. After the installation, all installation-related activities (welding, pressure test etc.) are the responsibility of the customer. Concrete pipe Transducer and holder available in length L = 230, allowing a pipe wall thickness up to 200 mm (7.9") and pipe sizes DN 600 Concrete Mounting plates1): (not included) Stainless steel Transducer holder: Stainless steel AISI 316 or similar 3 Pipe wall thickness 1) Mounting plates are only included for empty pipe installation types (refer to selection "A"). For tapping-band types holder and mounting plates are not included (refer to selection "C"). Installation requirements min. (1 x DN) + 1500 min. 1400 Empty pipe installation 3/276 Siemens FI 01 · 2016 min. 1400 min. 100 min. 500 min. 100 min. 500 min. (1 x DN) + 1500 min. (1 x DN) + 1000 min. (1 x DN) + 1000 The space requirements (in mm) around the pipe for retrofitting a SITRANS F US ultrasonic flowmeter type SONOKIT are given below: Hot-tap installation © Siemens AG 2016 Flow Measurement SITRANS F US Inline Flowmeter SONOKIT (with FUS060 or FUS080) Selection and Ordering data Article No. SITRANS F US SONOKIT 1-path sensor 7 ME 3 2 1 0 - Ord. code 7 77 7 7 - 7 7 7 7 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Selection and Ordering data Article No. SITRANS F US SONOKIT 1-path sensor 7 ME 3 2 1 0 7777 7 - 7 7 7 7 7 7 7 IP68 SS housing, Sylgard potting kit, PN 40, O-ring, 200 °C (392 °F), no approval 4 IP67 SS housing, PN 40, O-ring, 190 °C (374 °F), Ex i type, ATEX approval (only with FUS060 Ex) 5 Diameter Qn setting [m3/h] DN 100 (4") DN 125 (5") DN 150 (6") 100 150 220 1P 1T 2B DN 200 (8") DN 250 (10") DN 300 (12") 380 600 850 2F 2K 2P DN 350 (14") DN 400 (16") DN 450 (18") 1000 1300 1700 2T 3B 3F DN 500 (20") DN 550 (22") DN 600 (24") 2200 2600 3200 3K 3P 3T IP65 (NEMA 4), 120/230 V AC IP65 (NEMA 4), 24 V AC/DC IP65 (NEMA 4), 24 V AC/DC Ex version DN 650 (26") DN 700 (28") DN 750 (30") 3600 4200 4800 4B 4F 4K Transmitter version of SITRANS FUS080 (only DN 100 ... 1200 (4" ... 48")) DN 800 (32") DN 900 (36") DN 1000 (40") 5500 7500 9000 4P 5B 5K DN 1100 (44") DN 1200 (48") 10000 13200 5P 5T DN 1300 (52") DN 1400 (56") DN 1500 (60") 14000 16800 19000 6A 6C 6E DN 1600 (64") DN 1700 (68") DN 1800 (72") 22800 25000 27600 6G 6J 6L DN 1900 (76") DN 2000 (80") DN 2100 (84") 31000 36000 37000 6N 6Q 6S DN 2200 (88") DN 2300 (92") DN 2400 (96") 42000 45000 51000 6U 6W 7A Cable gland entries Cable glands M20 in transducers and in transmitter M25/20/16 x 1.5 (FUS080 only M20) Cable glands ½" NPT in transducers and in transmitter (only with FUS060) Transducer holder None (for tapping band) Carbon steel, length = 160 mm, mounting plates in carbon steel Stainless steel, length = 160 mm, mounting plates in stainless steel Stainless steel, length = 230 mm, for concrete pipe (DN 600 ... DN 2400) 1 3 2 Transmitter version of SITRANS FUS060 (only DN 100 ... 2400 (4" ... 96") N P Q PDM software tool and IrDA-adapter, which are needed for settings update, to be ordered separately, see FUS080 accessories IP67/NEMA 4X/6 115 ... 230 V AC IP67/NEMA 4X/6 3.6 V battery version, incl. dual battery pack IP67/NEMA 4X/6 115 ... 230 V AC, incl. 3.6 V single battery backup IP67/NEMA 4X/6 3.6 V battery version (no battery pack included)2) Only for FUS060 Installation method3) Empty pipe (incl. transducer holder and mounting plates). Alignment rods and tools must be ordered as accessories. Hot tap, mounting under pressure (mounting plates not incl.). Special mounting tools to be ordered separately. SONOKIT for tapping band (DN 200 ... DN 1800) (trandsducer holder and mounting plates not incl., tapping band to be ordered separately)1) Ord. code U V W X Transmitter output module Transmitter SITRANS FUS080: A Pulse and/or alarm output (standard for FUS080). Transmitter SITRANS FUS060: HART, 1 pulse output, 1 relay HART Ex version, 1 pulse output, 1 relay B C PROFIBUS PA, 1 pulse/frequency D Transducer coaxial cables (with FUS080 only, 15 and 30 m, 70°C (158 °F) cable types) A B C 0 1 2 x 3 m, max. 70 °C (158 °F), the only option for Ex i 2 x 15 m, max. 70 °C (158 °F) 2 x 30 m, high temp. max. 200 °C (392 °F) 0 2 x 30 m, max. 70 °C (158 °F) 2 x 60 m, max. 70 °C (158 °F) 2 x 90 m, max. 70 °C (158 °F) 3 4 5 2 x 120 m, max. 70 °C (158 °F) 2 x 3 m, high temp. max. 200 °C (392 °F), the only option for Ex i 2 x 15 m, high temp. max. 200 °C (392 °F) 6 7 Special version (add Order code): No transducer cable, cable length 2 x 3 m, the only option for Ex i No transducer cable, cable length 2 x 15 m 2 3 1 2 8 9 R0A 9 R0B No transducer cable, cable length 2 x 30 m No transducer cable, cable length 2 x 60 m 9 R0C 9 R0D 1 No transducer cable, cable length 2 x 90 m No transducer cable, cable length 2 x 120 m 9 R0E 9 R0F IP68 SS housing, PN 40, O-ring, 180 °C (356 °F), Ex d, ATEX approval (only with standard FUS060) 2 1) Tapping band via special request (PVR) 2) IP68 PA housing, Sylgard potting kit, PN 40, O-ring, 100 °C (212 °F), no approval 3 Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and UN 3091". Special transport documentation is required to observe these regulations. This may influence both transport time and costs." 3) Mounting tools must be ordered separately as "-Z"-options. Transducer type and approval IP67 (NEMA 4X/6) PA housing, PN 40, O-ring, 100 °C (212 °F), no approval Siemens FI 01 · 2016 3/277 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Flowmeter SONOKIT (with FUS060 or FUS080) Order code Selection and Ordering data Additional information Please add „-Z" to Article No. and specify Order code(s) and plain text. Material certificate EN 10204-3.1, transducer body material EN 10204-3.1, transducer holder material EN 10204-3.1, mounting plate material F30 F31 F32 Tag name plate 3 Stainless steel TAG plate (1 x 24 x 80 mm), wire fixed. Font size depends on text length: 8 mm for 1 ... 10 characters, 4 mm for 11 ... 20 characters (specify in plain text). Y17 Accessories Alignment rods-set for DN 100 ... 650 (4" ... 26") = 25 mm, L = 500 mm, 3 pcs. S10 Alignment rods-set for DN 700 ... 1900 (28" ... 76") = 25 mm, L = 500 mm, 6 pcs. S11 Alignment rods-set for DN 2000 ... 2400 (80" ... 96") = 25 mm, L = 500 mm, 8 pcs. S12 Spanner key for tranducer mounting type SONO 3200 O-ring type Tool set with various mounting/spare parts for SONOKIT installation T11 T12 Operating instructions Article No. Description SITRANS FUS060 • English A5E01204521 • German A5E02123845 SITRANS FUS080 • English A5E03059912 • German A5E31628428 SITRANS F US SONOKIT 1-path • English A5E00814557 • German A5E02610428 This device is shipped with a Quick Start guide and a CD containing further SITRANS F US literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Please use online Product selector to get latest updates. Product selector link: www.pia-portal.automation.siemens.com 3/278 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Flowmeter SONOKIT (with FUS060 or FUS080) Selection and Ordering data SITRANS F US SONOKIT 2-path sensor Article No. 7 77 7 7 - 7 7 7 7 7 7 7 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Qn setting [m3/h] DN 200 (8") DN 250 (10") DN 300 (12") 380 600 850 2F 2K 2P DN 350 (14") DN 400 (16") DN 450 (18") 1000 1300 1700 2T 3B 3F DN 500 (20") DN 550 (22") DN 600 (24") 2200 2600 3200 3K 3P 3T DN 650 (26") DN 700 (28") DN 750 (30") 3600 4200 4800 4B 4F 4K DN 800 (32") DN 900 (36") DN 1000 (40") 5500 7500 9000 4P 5B 5K DN 1100 (44") DN 1200 (48") 10 000 13 200 5P 5T DN 1300 (52") DN 1400 (56") DN 1500 (60") DN 1600 (64") 14 000 16 800 19 000 22 800 6A 6C 6E 6G DN 1700 (68") DN 1800 (72") DN 1900 (76") 25 000 27 600 31 000 6J 6L 6N DN 2000 (80") DN 2100 (84") DN 2200 (88") 36 000 37 000 42 000 6Q 6S 6U DN 2300 (92") DN 2400 (96") DN 2500 (100") 45 000 51 000 53 000 6W 7A 7C DN 2600 (104") DN 2700 (108") DN 2800 (112") 60 000 62 000 72 000 7E 7G 7J DN 2900 (116") DN 3000 (120") 71 000 78 000 7L 7N 2) Ord. code 7 ME 3 2 2 0 7777 7 - 7 7 7 7 7 7 7 None (for tapping band) Carbon steel, length = 160 mm, mounting plates in carbon steel Stainless steel, length = 160 mm, mounting plates in stainless steel Stainless steel, length = 230 mm, for concrete pipe (DN 600 ... DN 4000) 0 1 2 3 3 Transducer type and approval IP67 (NEMA 4X/6) PA housing, PN 40, O-ring, 100 °C (212 °F), no approval 1 IP68 SS housing, PN 40, O-ring, 180 °C (356 °F), EEx d, ATEX approval (only with standard FUS060) 2 IP68 PA housing, Sylgard potting kit, PN 40, SS, O-ring, 100 °C (212 °F), no approval 3 IP68 SS housing, Sylgard potting kit, PN 40, SS, O-ring, 200 °C (392 °F), no approval 4 IP67 SS housing, PN 40, O-ring, 190 °C (374 °F), Ex i, ATEX approval (only with FUS060 Ex) 5 Cable gland entires Cable glands M20 in transducers and in transmitter M25/20/16 x 1.5 (FUS080 only M20) Only for FUS060 1) Article No. Selection and Ordering data SITRANS F US SONOKIT 2-path sensor Transducer holder Diameter Installation method2) Empty pipe (incl. transducer holder and mounting plates). Alignment rods and tools must be ordered as accessories. Hot tap, mounting under pressure (mounting plates not incl.). Special mounting tools to be ordered separately. SONOKIT for tapping band (DN 200 ... DN 1800) (trandsducer holder and mounting plates not incl., tapping band to be ordered separately)1) Ord. code 7 ME 3 2 2 0 - Cable glands ½" NPT in transducers and in transmitter (only with FUS060) 1 2 Transmitter version of SITRANS FUS060 (only DN 200 ... 4000 (8" ... 160")) IP65 (NEMA 4), 120/230 V AC IP65 (NEMA 4), 24 V AC/DC IP65 (NEMA 4), 24 V AC/DC Ex version N P Q Transmitter version of SITRANS FUS080 (only DN 200 ... 1200 (8" ... 48")) PDM software tool and IrDA-adapter, which are needed for settings update, to be ordered separately, see FUS080 accessories A IP67/NEMA 4X/6 115 ... 230 V AC IP67/NEMA 4X/6 3.6 V battery version, incl. dual battery pack IP67/NEMA 4X/6 115 ... 230 V AC, incl. 3.6 V single battery backup IP67/NEMA 4X/6 3.6 V battery version (no battery pack included)4) U V W X Transmitter output module B C Tapping band via special request (PVR) Mounting tools must be orderd separately as "-Z" options Transmitter SITRANS FUS080: Pulse and/or alarm output (standard for FUS080). Transmitter SITRANS FUS060: HART, 1 pulse output, 1 relay HART Ex version, 1 pulse output, 1 relay A PROFIBUS PA, 1 pulse/frequency D Siemens FI 01 · 2016 B C 3/279 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Flowmeter SONOKIT (with FUS060 or FUS080) Selection and Ordering data SITRANS F US SONOKIT 2-path sensor 3 Article No. Ord. code Order code Selection and Ordering data 7 ME 3 2 2 0 - Additional information 7 77 7 7 - 7 7 7 7 7 7 7 Please add „-Z" to Article No. and specify Order code(s) and plain text. Transducer coaxial cables (with FUS080 only, 15 and 30 m, 70°C (158 °F) cable types) 4 x 3 m, max. 70 °C (158 °F), the only option for Ex i 4 x 15 m, max. 70 °C (158 °F) 4 x 30 m, high temp. max. 200 °C (392 °F) 4 x 30 m, max. 70 °C (158 °F) 0 1 2 3 4 x 60 m, max. 70 °C (158 °F) (up to DN 3000) 4 x 90 m, max. 70 °C (158 °F) (up to DN 3000) 4 x 120 m, max. 70 °C (158 °F) (up to DN 3000) 4 5 6 Tag name plate Stainless steel TAG plate (1 x 24 x 80 mm), wire fixed. Font size depends on text length: 8 mm for 1 ... 10 characters, 4 mm for 11 ... 20 characters (specify in plain text). 4 x 3 m, high temp. max. 200 °C (392 °F), the only option for Ex i 4 x 15 m, high temp. max. 200 °C (392 °F) 7 Accessories Material certificate 8 Special version (add Order code): No transducer cable, cable length 4 x 3 m, the only option for Ex i No transducer cable, cable length 4 x 15 m 9 R0A No transducer cable, cable length 4 x 30 m No transducer cable, cable length 4 x 60 m (up to DN 3000) 9 R0C 9 R0D No transducer cable, cable length 4 x 90 m (up to DN 3000) No transducer cable, cable length 4 x 120 m (up to DN 3000) 9 R0E 9 R0B 9 R0F EN 10204-3.1, transducer body material EN 10204-3.1, transducer holder material EN 10204-3.1, mounting plate material F30 F31 F32 Y17 Alignment rods-set for DN 100 ... 750 (4" ... 30") = 25 mm, L = 500 mm, 3 pcs. Alignment rods-set for DN 800 ... 2100 (32" ... 84") = 25 mm, L = 500 mm, 6 pcs. Alignment rods-set for DN 2200 ... 3000 (88" ... 120") = 25 mm, L = 500 mm, 8 or 10 pcs. S10 Spanner key for tranducer mounting type SONO 3200 O-ring type Tool set with various mounting/spare parts for SONOKIT installation T11 S11 S12 T12 Operating instructions Article No. Description SITRANS FUS060 • English A5E01204521 • German A5E02123845 SITRANS FUS080 • English A5E03059912 • German A5E31628428 SITRANS F US SONOKIT 2-path • English A5E02445496 • German A5E02554972 This device is shipped with a Quick Start guide and a CD containing further SITRANS F US literature. All literature is available to download for free, in a range of languages, at www.siemens.com/processinstrumentation/documentation Please use online Product selector to get latest updates. Product selector link: www.pia-portal.automation.siemens.com 3/280 Siemens FI 01 · 2016 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Flowmeter SONOKIT (with FUS060 or FUS080) ■ Flowmeter SONOKIT accessories and spare parts Accessories Potting kit for SONO 3200 terminal housing Description Article No. Potting kit for terminal box of SONO 3200 transducers for IP68/NEMA 6P (not for Ex sensors) FDK:085L2403 3 Tools for SONO 3200 transducers and SONOKIT Description Article No. Extraction tool for replacement of SONO 3200 O-ring transducers under pressure and for hot-tapping (working conditions: typically water, max. 40 bar and max. 60 °C (max. 580 psi and max. 140 °F)) For transducer length: • Up to 160 mm (6.3") FDK:085B5333 • Up to 230 mm (9.1") FDK:085B5335 Angle measurement tool for SONOKIT FDK:085B5330 Hot-tap drilling tool for SONOKIT, the extraction tool is required, max. pressure 40 bar (580 psi) FDK:085B5392 Alignment tool for SONOKIT (typically for hot-tapping) For use on pipe sizes in the range DN 300 to DN 1200. FDK:085B5393 Description Article No. Alignment rods-set for DN 100 ... 650 (4" ... 26"), = 25 mm, L = 500 mm, 3 pcs. A5E02609214 Alignment rods-set for DN 700 ... 1900 (28" ... 76"), = 25 mm, L = 500 mm, 6 pcs. A5E02609215 Alignment rods-set for DN 2000 ... 3000 (80" ... 120"), = 25 mm, L = 500 mm, 10 pcs. A5E02609216 Spanner key for tranducer mounting type SONO 3200 O-ring type A5E02609218 Tool set with various mounting/spare parts for SONOKIT installation A5E02609219 Siemens FI 01 · 2016 3/281 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Flowmeter SONOKIT (with FUS060 or FUS080) Cable connection boxes (For the connection of individual transducer cables with the FUS060 transducer cables) Article No. Description Junction box for coaxial cable 3 • IP65 metal box for 2 coaxial cables FDK:085B1360 • IP65 metal box for 4 coaxial cables FDK:085B1361 • IP65 EEx e plastic box for 2 coaxial cables, no ATEX approval FDK:085B1362 • IP65 EEx e plastic box for 4 coaxial cables, no ATEX approval FDK:085B1363 Spare parts Transducer SONO 3200 spare parts, complete transducer with ½"-NPT cable glands Approval Temperature range Length Article No. [°C (°F)] [mm (inch)] TransMaterial Gasket ducer type Pressure Terminal rating housing O-ring 316 SS O-ring PN 40 Plastic PA 6.6 -20 … +100 (-4 ... +212) 160 (6.3) A5E00839476 O-ring 316 SS O-ring PN 40 316 SS -20 … +2001) (-4 ... +392) 160 (6.3) A5E00839435 O-ring 316 SS O-ring PN 40 Plastic PA 6.6 -20 … +100 (-4 ... +212) 230 (9.41) A5E00839477 O-ring 316 SS O-ring PN 40 316 SS -20 … +2001) (-4 ... +392) 230 (9.41) A5E00839437 1) 316 SS housing for -20 ... +200 °C (-4 ... +392 °F) media temp. but cable glands only for -20 ... +100 °C (-4 ... +212 °F) ambient temp. Transducer SONO 3200 spare parts, complete transducer with M20 cable glands Approval Temperature range Length Article No. [°C (°F)] [mm (inch)] TransMaterial Gasket ducer type Pressure Terminal rating housing O-ring 316 SS O-ring PN 40 Plastic PA 6.6 -20 … +100 (-4 ... +212) 160 (6.3) FDK:085B5454 O-ring 316 SS O-ring PN 40 316 SS -20 … +2001) (-4 ... +392) 160 (6.3) FDK:085B5455 O-ring 316 SS O-ring PN 40 Plastic PA 6.6 -20 … +100 (-4 ... +212) 230 (9.41) FDK:085B5458 O-ring 316 SS O-ring PN 40 316 SS Ex d2) -20 … +200 (-4 ... +392) 160 (6.3) FDK:085B5452 O-ring 316 SS O-ring PN 40 316 SS Ex i3) -10 … +200 (14 ... 392) 160 (6.3) A5E00836462 O-ring 316 SS O-ring PN 40 316 SS -20 … +2002) (-4 ... +392) 230 (9.41) FDK:085B5459 1) 316 SS housing for -20 ... +200 °C (-4 ... +392 °F) media temp. but cable glands only for -20 ... +100 °C (-4 ... +212 °F) ambient temp. 2) ATEX (Ex) IIC 2G Ex d IIC T3-T6 Gb 3) For systems with FUS060 ATEX IIC 2G Ex dem [ia/ib] T6/T4/T3 Transducer SONO 3200 spare parts, transducer terminal housing with M20 cable glands Type Article No. Material: PA 6.6, Temperature range: -20 … +100 °C (-4 ... +212 °F) FDK:085B5501 Material: AISI 316, Temperature range: -20 … +200 °C (-4 ... +392 °F) FDK:085B5504 Material: AISI 316, Ex d1), Temperature range: -20 … +200 °C (-4 ... +392 °F) Material: AISI 316, Ex i2), Temperature range: -10 … +200 °C (14 ... 392 °F) 1) ATEX (Ex) IIC 2G Ex d IIC T3-T6 Gb 2) For systems with FUS060 ATEX IIC 2G Ex dem [ia/ib] T6/T4/T3 3/282 Siemens FI 01 · 2016 FDK:085B5505 A5E00835255 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Flowmeter SONOKIT (with FUS060 or FUS080) Transducer SONO 3200 spare parts, transducer terminal housing with ½"-NPT cable glands Type Article No. Material: PA 6.6, Temperature range: -20 … +100 °C (-4 ... +212 °F) A5E00839460 Material: AISI 316, Temperature range: -20 … +200 °C (-4 ... +392 °F) A5E00839427 Transducer SONO 3200 spare parts transducer body with insert as well as insert only Temperature range [°C (°F)] Gasket Length [mm (inch)] Article No. -20 … +200 (-4 ... +392) O-ring (FFKM O-ring material)1) 160 (6.3) FDK:085B1406 -20 … +200 (-4 ... +392) O-ring (FKM 602 O-ring material)2) 160 (6.3) FDK:085B5510 -20 … +200 (-4 ... +392) O-ring 230 (9.41) FDK:085B5511 1) 2) 3 Chemical resistant O-ring material. Body specially for Ex-approved transducers. Body specially for standard transducers. Temperature range [°C (°F)] Length [mm (inch)] Article No. -20 … +200 (-4 ... +392) 160 (6.3) FDK:085B1419 -20 … +200 (-4 ... +392) 230 (9.41) FDK:085B1420 Transducer SONO 3200 gasket Type Pressure rating Material Gasket O-ring (3 pcs. for O-ring transducers) PN 40 FKM Temperature range [°C (°F)] Article No. -20 … +200 (-4 ... +392) FDK:085B1089 Cables for SONOKIT SONO 3200 transducers with FUS060 Description Length [m (ft)] Article No. Coaxial cable for FUS060, (75 , max. 70 ºC (158 ºF), black PVC) (2 pcs.) 3 (9.84) A5E00875101 15 (49.21) A5E00861432 30 (98.43) A5E01278662 60 (196.85) A5E01278682 90 (295.28) A5E01278687 120 (393.70) A5E01278698 3 (9.84) A5E00875105 15 (49.21) A5E00861435 30 (98.43) A5E01196952 Description Length [m (ft)] Article No. Coaxial cable for FUS080, (75 , max. 70 ºC (158 ºF), black PVC) (2 pcs.) 15 (49.21) A5E02478541 30 (98.43) A5E02478751 High temp. coaxial cable for FUS060; with 0.3 m brown PTFE high temp. transducer part, max. 200 °C (392 °F) and black PVC transmitter part with SMB plug, max. 70 ºC (158 ºF); (impedance 75 ) (2 pcs.) Cables for SONOKIT SONO 3200 transducers with FUS080 Siemens FI 01 · 2016 3/283 © Siemens AG 2016 Flow Measurement SITRANS F US Inline Flowmeter SONOKIT (with FUS060 or FUS080) Transducer holder for SONOKIT SONO 3200 transducers Type/ description Temperature range [°C (°F)] • 160 mm (6.3") stainless steel 45°, DN 100 … DN 150 (4" ... 6") FDK:085L1103 -20 ... 100 (-4 ... +212) A5E02246304 • 160 mm (6.3") carbon steel 45°, DN 100 … DN 150 (4" ... 6") FDK:085L1102 black PA plastic, cable Ø 5 ... 13 mm (1 pc.) ½" NPT gray -20 ... 100 PA plastic, (-4 ... +212) cable Ø 5 ... 9 mm (1 pc.) A5E02246309 ½" NPT -40 ... 100 crome(-40 ... +212) plated brass, cable Ø 5 ... 9 mm (1 pc.) A5E02246258 Ex i M20 stain- -25 ... 200 (-13 ... +392) less steel, cable Ø 4 ... 6 mm (1 pc.) A5E02246194 1-path (each incl. 1 pc.) 3 SONO 3200 cable glands Article No. Description • 230 mm (9.1") for concrete FDK:085L1107 pipe 60°, DN 600 … DN 2400 (24" ... 96") • 160 mm (6.3") stainless steel 60°, DN 200 … DN 2400 (8" ... 96") FDK:085L1105 • 160 mm (6.3") carbon steel 60°, DN 200 … DN 2400 (8" ... 96") FDK:085L1104 2-path (each incl. 1 pc.) • 230 mm (9.1") for concrete FDK:085L1111 pipe 60°, DN 600 … DN 3000 (24" ... 120") • 160 mm (6.3") stainless steel 60°, DN 200 … DN 3000 (8" ... 120") FDK:085L1109 • 160 mm (6.3") carbon steel 60°, DN 200 … DN 3000 (8" ... 120") FDK:085L1108 The other transducer holder parts are either completely in stainless steel for the concrete and stainless steel pipes (AISI 316L/1.4404 or similar). For carbon pipes the part welded onto the pipe is in carbon steel (St.37 or similar). Thread part is stainless steel (AISI 316L/1.4404 or similar). Mounting plate for SONOKIT SONO 3200 transducers Article No. Description 1-path (each incl. 1 pc.) • Stainless steel plate, 45°, DN 100 … DN 150 (4" ... 6") FDK:085L1113 • Carbon steel plate, 45°, DN 100 … DN 150 (4" ... 6") FDK:085L1112 • Stainless steel plate, 60°, FDK:085L1115 DN 200 … DN 2400 (8" ... 96") • Carbon steel plate, 60°, FDK:085L1114 DN 200 … DN 2400 (8" ... 96") 2-path (each incl. 1 pc.) • Stainless steel plate, 60°, DN 200 … DN 3000 (8" ... 120") FDK:085L1119 • Carbon steel plate, 60°, DN 200 … DN 3000 (8" ... 120") FDK:085L1118 The mounting plates are either in stainless steel (AISI 316L/1.4404 or similar) or carbon steel (St.37 or similar). 3/284 Siemens FI 01 · 2016 Appr Article No. Ex d A5E02246311 M20 stain- -60 ... 180 (-76 ... +356) less s teel, cable Ø 5 ... 8 mm (1 pc.) © Siemens AG 2016 Flow Measurement SITRANS F US Inline Flowmeter SONOKIT (with FUS060 or FUS080) ■ Schematics 1 Xi 4 Path 1 Sensor 1 4 1A 1A 2B 1B 2A 1 2B 4 Path 2 1A 1B 2A 2B 3 Sensor 1 2A 4 Electrical connection of SITRANS FUS060 and SONOKIT 2-path. Max. 30 m transducer cable length for sizes DN 3000. Track 1 1 1B 4 Sensor 1A 1B 1 4 1A 1A 2B 1B 2A Electrical connection of SITRANS FUS060 and SONOKIT 1-path 2A 1A 2A 1A 2A 1A 2A 1A 2A 1A 1B 2B 2A 1A 1B 2B 1B 2B 1A 1B 2B 1B 2B 1B 1A 2A 1B 2B 1B 2B Electrical connection of SITRANS FUS080 and SONOKIT 2-path Electrical connection of SITRANS FUS080 and SONOKIT 1-path Siemens FI 01 · 2016 3/285