SITRANS F SONOKIT (FUS060 or FUS080) for retrofit on existing pipelines

© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONOKIT (with FUS060 or FUS080)
■ Overview
■ Design
The SONOKIT package box contains all necessary parts to build
an ultrasonic flowmeter on existing pipes depending on choices
at ordering:
• Papers to wrap around pipes for alignment of sensors
• Transducer alignment tools
• Mounting plates, transducer holders and SONO 3200 transducers
• Transducer cables
• SITRANS FUS060 or FUS080 transmitter for wall mounting
• 4-path version (up to DN 1500 (60")) is available on special request (PVR)
■ Technical specifications
SONOKIT is a transit time based ultrasonic flowmeter for retrofitting on existing pipelines.
The transmitter related to this system is the
SITRANS FUS080 or FUS060.
Technical specifications to the FUS060 see page 3/247 and to
FUS080 see page 3/253.
Accuracy
• 2-path:   (0.5 … 1.5 %)
• 1-path:   (1 … 3 %)
The kit offers all necessary parts and special tools to make the
installation as 1-path or 2-path flowmeter.
Typical, depending on accuracy of
measurements of installation
The set is made for installation on empty pipes or pipes under
pressure without process shut-down (hot-tap).
Note:
Accuracy depends on the accuracy of the measurements taken at location. This means that inaccurate measurements of angles, distance
between transducers, wall thickness and pipe diameter have a direct
effect on the accuracy. Values measured are entered into the memory of
the FUS060 or FUS080 transmitter.
Please contact Siemens for further information on hot-tap tools
and instructions.
SONOKIT has inline transducers (in contact with media) which
assure superior accuracy and performance.
■ Benefits
• Cost-effective solution – contains all the necessary components for retrofitting
• SONOKIT is easy to install in pipeline sizes DN 200 to
DN 3000 (8" to 120") 1-path DN 100 to DN 2400 (4" to 96").
• No bypass installation necessary – withstands pressures up to
40 bar (580 psi) and media temperatures between -20 °C and
+200 °C (-4 °F and +392 °F)
• High accuracy – the bigger the pipe, the more accurate the result
• Solid construction and no moving parts for a 100 % maintenance and obstruction-free flowmeter
• The SONOKIT comes with transducers in IP68 enclosure
• Available in a robust version that can be buried and withstands constant flooding
• Inline transducers assure superior accuracy and performance
• Automatic calculation of the calibration factor when pipe
geometry data are entered in the transmitter
• FUS060 transmitter versions with HART or PROFIBUS PA
• FUS080 transmitter, battery or mains-powered
Requirements for pipes
Size
FUS060:
DN 100 … DN 3000 (4" … 120")
FUS080:
DN 100 … DN 1200 (4" … 48")
Line pressure
max. 40 bar (580 psi)
Media temperature
• Standard
-10 ... +200 °C (14 ... 392 °F)
• ATEX Ex d version
-20 .... +200 °C (-4 … +392 °F)
• ATEX Ex i version
-10 ... +200 °C (+14 ... +392 °F)
• Specials
-200 °C (-328 °F) or
up to 250 °C (482 °F)
Ambient temperature sensor
• Standard and Ex-i version
-20 ... +60 °C (-4 ... +140 °F)
• Ex d version
-20 ... +180 °C (-4 ... +356 °F)
Transducer enclosure/
approvals/certificates
Standard version
IP67 (NEMA 6)/IP68 (NEMA 6P)
Ex approval
System ATEX approval for
SONO 3200 Ex i transducers
together with transmitter
FUS060-Ex:
ATEX II 2 G Ex dem [ia/ib] IIC
T6/T4/T3 Gb or
ATEX II 2G Ex d IIC T3-T6 Gb with
SONO 3200 Ex d transducers (for
standard FUS060 transmitter,
installed outside of Ex zone)
Material certificates
EN 10204-3.1 material certificate
on transducer mounting parts
■ Application
•
•
•
•
•
•
•
•
•
Raw water intake for water treatment plants
Water distribution systems
Irrigation systems
Power generation (energy and water)
District heating plants
Cooling water plants within the industry and in power stations
Systems within the oil and refinery business
Sewage treatment plants
Plants transporting non-conductive liquids
Transducer materials
Terminal housing
Standard version: PA 6.6, 100 °C
(212 °F) or stainless steel
AISI 316, 200 °C (392 °F)
Transducer body
Standard version: Stainless steel
AISI 316, 200 °C (392 °F)
Siemens FI 01 · 2016
3/275
3
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONOKIT (with FUS060 or FUS080)
Materials of existing pipeline
Steel
Transducer holder: EN 10273 or
EN 10216 (P235GH)
Mounting plates1): EN 10273 or
EN 10216 (P235GH)
Transducer holder: Stainless steel
AISI 316 or similar
Dimension of the package box
(L x W x H, approx.)
856 x 390 x 344 mm
(33.7" x 15.4" x 13.5")
Weight example of a package
(standard 2-path with FUS060)
approx. 53 kg (116.8 lb)
Certificates and approvals
Conformity certificate
The devices are supplied as
standard with a Siemens
Certificate of Conformity on a CD
Material certificate
Mounting plates1): Stainless steel
AISI 316 or similar
Material certificate for the transducer parts according to
EN 10204-3.1 is optionally available
Approvals
No custody transfer approvals
Steel pipe (AISI 316 and St. 37.2 or
corresponding material)
Transducer and holder available
in length L = 160, allowing a pipe
wall thickness up to 20 mm
(0.79")
Information on PED approval:
The SONOKIT includes the pipe mounting parts only and therefore it
cannot be PED-approved. After the installation, all installation-related
activities (welding, pressure test etc.) are the responsibility of the customer.
Concrete pipe
Transducer and holder available
in length L = 230, allowing a pipe
wall thickness up to 200 mm
(7.9") and pipe sizes  DN 600
Concrete
Mounting plates1): (not included)
Stainless steel
Transducer holder: Stainless steel
AISI 316 or similar
3
Pipe wall thickness
1)
Mounting plates are only included for empty pipe installation types (refer to
selection "A"). For tapping-band types holder and mounting plates are not
included (refer to selection "C").
Installation requirements
min. (1 x DN) + 1500
min. 1400
Empty pipe installation
3/276
Siemens FI 01 · 2016
min. 1400
min. 100
min. 500
min. 100
min. 500
min. (1 x DN) + 1500
min. (1 x DN) + 1000
min. (1 x DN) + 1000
The space requirements (in mm) around the pipe for retrofitting a SITRANS F US ultrasonic flowmeter type SONOKIT are given below:
Hot-tap installation
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONOKIT (with FUS060 or FUS080)
Selection and Ordering data
Article No.
SITRANS F US SONOKIT
1-path sensor
7 ME 3 2 1 0 -
Ord. code
7 77 7 7 - 7 7 7 7 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Selection and Ordering data
Article No.
SITRANS F US SONOKIT
1-path sensor
7 ME 3 2 1 0 7777 7 - 7 7 7 7 7 7 7
IP68 SS housing, Sylgard potting kit, PN 40,
O-ring, 200 °C (392 °F), no approval
4
IP67 SS housing, PN 40, O-ring, 190 °C
(374 °F), Ex i type, ATEX approval
(only with FUS060 Ex)
5
Diameter
Qn setting [m3/h]
DN 100 (4")
DN 125 (5")
DN 150 (6")
100
150
220
1P
1T
2B
DN 200 (8")
DN 250 (10")
DN 300 (12")
380
600
850
2F
2K
2P
DN 350 (14")
DN 400 (16")
DN 450 (18")
1000
1300
1700
2T
3B
3F
DN 500 (20")
DN 550 (22")
DN 600 (24")
2200
2600
3200
3K
3P
3T
IP65 (NEMA 4), 120/230 V AC
IP65 (NEMA 4), 24 V AC/DC
IP65 (NEMA 4), 24 V AC/DC Ex version
DN 650 (26")
DN 700 (28")
DN 750 (30")
3600
4200
4800
4B
4F
4K
Transmitter version of SITRANS FUS080
(only DN 100 ... 1200 (4" ... 48"))
DN 800 (32")
DN 900 (36")
DN 1000 (40")
5500
7500
9000
4P
5B
5K
DN 1100 (44")
DN 1200 (48")
10000
13200
5P
5T
DN 1300 (52")
DN 1400 (56")
DN 1500 (60")
14000
16800
19000
6A
6C
6E
DN 1600 (64")
DN 1700 (68")
DN 1800 (72")
22800
25000
27600
6G
6J
6L
DN 1900 (76")
DN 2000 (80")
DN 2100 (84")
31000
36000
37000
6N
6Q
6S
DN 2200 (88")
DN 2300 (92")
DN 2400 (96")
42000
45000
51000
6U
6W
7A
Cable gland entries
Cable glands M20 in transducers and in
transmitter M25/20/16 x 1.5
(FUS080 only M20)
Cable glands ½" NPT in transducers and in
transmitter (only with FUS060)
Transducer holder
None (for tapping band)
Carbon steel, length = 160 mm, mounting
plates in carbon steel
Stainless steel, length = 160 mm, mounting
plates in stainless steel
Stainless steel, length = 230 mm, for concrete pipe (DN 600 ... DN 2400)
1
3
2
Transmitter version of SITRANS FUS060
(only DN 100 ... 2400 (4" ... 96")
N
P
Q
PDM software tool and IrDA-adapter, which
are needed for settings update, to be
ordered separately, see FUS080 accessories
IP67/NEMA 4X/6 115 ... 230 V AC
IP67/NEMA 4X/6 3.6 V battery version,
incl. dual battery pack
IP67/NEMA 4X/6 115 ... 230 V AC, incl. 3.6 V
single battery backup
IP67/NEMA 4X/6 3.6 V battery version
(no battery pack included)2)
Only for FUS060
Installation method3)
Empty pipe (incl. transducer holder and
mounting plates). Alignment rods and tools
must be ordered as accessories.
Hot tap, mounting under pressure (mounting
plates not incl.). Special mounting tools to
be ordered separately.
SONOKIT for tapping band
(DN 200 ... DN 1800) (trandsducer holder
and mounting plates not incl., tapping band
to be ordered separately)1)
Ord. code
U
V
W
X
Transmitter output module
Transmitter SITRANS FUS080:
A
Pulse and/or alarm output (standard for
FUS080).
Transmitter SITRANS FUS060:
HART, 1 pulse output, 1 relay
HART Ex version, 1 pulse output, 1 relay
B
C
PROFIBUS PA, 1 pulse/frequency
D
Transducer coaxial cables
(with FUS080 only, 15 and 30 m, 70°C
(158 °F) cable types)
A
B
C
0
1
2 x 3 m, max. 70 °C (158 °F), the only option
for Ex i
2 x 15 m, max. 70 °C (158 °F)
2 x 30 m, high temp. max. 200 °C (392 °F)
0
2 x 30 m, max. 70 °C (158 °F)
2 x 60 m, max. 70 °C (158 °F)
2 x 90 m, max. 70 °C (158 °F)
3
4
5
2 x 120 m, max. 70 °C (158 °F)
2 x 3 m, high temp. max. 200 °C (392 °F),
the only option for Ex i
2 x 15 m, high temp. max. 200 °C (392 °F)
6
7
Special version (add Order code):
No transducer cable, cable length 2 x 3 m,
the only option for Ex i
No transducer cable, cable length 2 x 15 m
2
3
1
2
8
9 R0A
9 R0B
No transducer cable, cable length 2 x 30 m
No transducer cable, cable length 2 x 60 m
9 R0C
9 R0D
1
No transducer cable, cable length 2 x 90 m
No transducer cable, cable length 2 x 120 m
9 R0E
9 R0F
IP68 SS housing, PN 40, O-ring, 180 °C
(356 °F), Ex d, ATEX approval (only with
standard FUS060)
2
1)
Tapping band via special request (PVR)
2)
IP68 PA housing, Sylgard potting kit, PN 40,
O-ring, 100 °C (212 °F), no approval
3
Lithium batteries are subject to special transportation regulations according to United Nations "Regulation of Dangerous Goods, UN 3090 and UN
3091". Special transport documentation is required to observe these regulations. This may influence both transport time and costs."
3)
Mounting tools must be ordered separately as "-Z"-options.
Transducer type and approval
IP67 (NEMA 4X/6) PA housing, PN 40,
O-ring, 100 °C (212 °F), no approval
Siemens FI 01 · 2016
3/277
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONOKIT (with FUS060 or FUS080)
Order code
Selection and Ordering data
Additional information
Please add „-Z" to Article No. and specify Order
code(s) and plain text.
Material certificate
EN 10204-3.1, transducer body material
EN 10204-3.1, transducer holder material
EN 10204-3.1, mounting plate material
F30
F31
F32
Tag name plate
3
Stainless steel TAG plate (1 x 24 x 80 mm),
wire fixed. Font size depends on text length:
8 mm for 1 ... 10 characters, 4 mm for
11 ... 20 characters (specify in plain text).
Y17
Accessories
Alignment rods-set for DN 100 ... 650 (4" ... 26")
 = 25 mm, L = 500 mm, 3 pcs.
S10
Alignment rods-set for DN 700 ... 1900 (28" ... 76")
 = 25 mm, L = 500 mm, 6 pcs.
S11
Alignment rods-set for DN 2000 ... 2400 (80" ... 96")
 = 25 mm, L = 500 mm, 8 pcs.
S12
Spanner key for tranducer mounting type SONO 3200
O-ring type
Tool set with various mounting/spare parts for
SONOKIT installation
T11
T12
Operating instructions
Article No.
Description
SITRANS FUS060
• English
A5E01204521
• German
A5E02123845
SITRANS FUS080
• English
A5E03059912
• German
A5E31628428
SITRANS F US SONOKIT 1-path
• English
A5E00814557
• German
A5E02610428
This device is shipped with a Quick Start guide and a CD containing further SITRANS F US literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Please use online Product selector to get latest
updates. Product selector link:
www.pia-portal.automation.siemens.com
3/278
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONOKIT (with FUS060 or FUS080)
Selection and Ordering data
SITRANS F US SONOKIT
2-path sensor
Article No.
7 77 7 7 - 7 7 7 7 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Qn setting [m3/h]
DN 200 (8")
DN 250 (10")
DN 300 (12")
380
600
850
2F
2K
2P
DN 350 (14")
DN 400 (16")
DN 450 (18")
1000
1300
1700
2T
3B
3F
DN 500 (20")
DN 550 (22")
DN 600 (24")
2200
2600
3200
3K
3P
3T
DN 650 (26")
DN 700 (28")
DN 750 (30")
3600
4200
4800
4B
4F
4K
DN 800 (32")
DN 900 (36")
DN 1000 (40")
5500
7500
9000
4P
5B
5K
DN 1100 (44")
DN 1200 (48")
10 000
13 200
5P
5T
DN 1300 (52")
DN 1400 (56")
DN 1500 (60")
DN 1600 (64")
14 000
16 800
19 000
22 800
6A
6C
6E
6G
DN 1700 (68")
DN 1800 (72")
DN 1900 (76")
25 000
27 600
31 000
6J
6L
6N
DN 2000 (80")
DN 2100 (84")
DN 2200 (88")
36 000
37 000
42 000
6Q
6S
6U
DN 2300 (92")
DN 2400 (96")
DN 2500 (100")
45 000
51 000
53 000
6W
7A
7C
DN 2600 (104")
DN 2700 (108")
DN 2800 (112")
60 000
62 000
72 000
7E
7G
7J
DN 2900 (116")
DN 3000 (120")
71 000
78 000
7L
7N
2)
Ord. code
7 ME 3 2 2 0 7777 7 - 7 7 7 7 7 7 7
None (for tapping band)
Carbon steel, length = 160 mm, mounting
plates in carbon steel
Stainless steel, length = 160 mm, mounting
plates in stainless steel
Stainless steel, length = 230 mm, for concrete pipe (DN 600 ... DN 4000)
0
1
2
3
3
Transducer type and approval
IP67 (NEMA 4X/6) PA housing, PN 40,
O-ring, 100 °C (212 °F), no approval
1
IP68 SS housing, PN 40, O-ring, 180 °C
(356 °F), EEx d, ATEX approval
(only with standard FUS060)
2
IP68 PA housing, Sylgard potting kit, PN 40,
SS, O-ring, 100 °C (212 °F), no approval
3
IP68 SS housing, Sylgard potting kit, PN 40,
SS, O-ring, 200 °C (392 °F), no approval
4
IP67 SS housing, PN 40, O-ring, 190 °C
(374 °F), Ex i, ATEX approval (only with
FUS060 Ex)
5
Cable gland entires
Cable glands M20 in transducers and in
transmitter M25/20/16 x 1.5
(FUS080 only M20)
Only for FUS060
1)
Article No.
Selection and Ordering data
SITRANS F US SONOKIT
2-path sensor
Transducer holder
Diameter
Installation method2)
Empty pipe (incl. transducer holder and
mounting plates). Alignment rods and tools
must be ordered as accessories.
Hot tap, mounting under pressure (mounting
plates not incl.). Special mounting tools to
be ordered separately.
SONOKIT for tapping band
(DN 200 ... DN 1800) (trandsducer holder
and mounting plates not incl., tapping band
to be ordered separately)1)
Ord. code
7 ME 3 2 2 0 -
Cable glands ½" NPT in transducers and in
transmitter (only with FUS060)
1
2
Transmitter version of SITRANS FUS060
(only DN 200 ... 4000 (8" ... 160"))
IP65 (NEMA 4), 120/230 V AC
IP65 (NEMA 4), 24 V AC/DC
IP65 (NEMA 4), 24 V AC/DC Ex version
N
P
Q
Transmitter version of SITRANS FUS080
(only DN 200 ... 1200 (8" ... 48"))
PDM software tool and IrDA-adapter, which
are needed for settings update, to be
ordered separately, see FUS080 accessories
A
IP67/NEMA 4X/6 115 ... 230 V AC
IP67/NEMA 4X/6 3.6 V battery version, incl.
dual battery pack
IP67/NEMA 4X/6 115 ... 230 V AC, incl. 3.6 V
single battery backup
IP67/NEMA 4X/6 3.6 V battery version (no
battery pack included)4)
U
V
W
X
Transmitter output module
B
C
Tapping band via special request (PVR)
Mounting tools must be orderd separately as "-Z" options
Transmitter SITRANS FUS080:
Pulse and/or alarm output (standard for
FUS080).
Transmitter SITRANS FUS060:
HART, 1 pulse output, 1 relay
HART Ex version, 1 pulse output, 1 relay
A
PROFIBUS PA, 1 pulse/frequency
D
Siemens FI 01 · 2016
B
C
3/279
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONOKIT (with FUS060 or FUS080)
Selection and Ordering data
SITRANS F US SONOKIT
2-path sensor
3
Article No.
Ord. code
Order code
Selection and Ordering data
7 ME 3 2 2 0 -
Additional information
7 77 7 7 - 7 7 7 7 7 7 7
Please add „-Z" to Article No. and specify Order
code(s) and plain text.
Transducer coaxial cables
(with FUS080 only, 15 and 30 m,
70°C (158 °F) cable types)
4 x 3 m, max. 70 °C (158 °F), the only option for Ex i
4 x 15 m, max. 70 °C (158 °F)
4 x 30 m, high temp. max. 200 °C (392 °F)
4 x 30 m, max. 70 °C (158 °F)
0
1
2
3
4 x 60 m, max. 70 °C (158 °F) (up to DN 3000)
4 x 90 m, max. 70 °C (158 °F) (up to DN 3000)
4 x 120 m, max. 70 °C (158 °F) (up to DN 3000)
4
5
6
Tag name plate
Stainless steel TAG plate (1 x 24 x 80 mm),
wire fixed. Font size depends on text length:
8 mm for 1 ... 10 characters, 4 mm for
11 ... 20 characters (specify in plain text).
4 x 3 m, high temp. max. 200 °C (392 °F),
the only option for Ex i
4 x 15 m, high temp. max. 200 °C (392 °F)
7
Accessories
Material certificate
8
Special version (add Order code):
No transducer cable, cable length 4 x 3 m,
the only option for Ex i
No transducer cable, cable length 4 x 15 m
9 R0A
No transducer cable, cable length 4 x 30 m
No transducer cable, cable length 4 x 60 m
(up to DN 3000)
9 R0C
9 R0D
No transducer cable, cable length 4 x 90 m
(up to DN 3000)
No transducer cable, cable length 4 x 120 m
(up to DN 3000)
9 R0E
9 R0B
9 R0F
EN 10204-3.1, transducer body material
EN 10204-3.1, transducer holder material
EN 10204-3.1, mounting plate material
F30
F31
F32
Y17
Alignment rods-set for DN 100 ... 750 (4" ... 30")
 = 25 mm, L = 500 mm, 3 pcs.
Alignment rods-set for DN 800 ... 2100 (32" ... 84")
 = 25 mm, L = 500 mm, 6 pcs.
Alignment rods-set for DN 2200 ... 3000 (88" ... 120")
 = 25 mm, L = 500 mm, 8 or 10 pcs.
S10
Spanner key for tranducer mounting type
SONO 3200 O-ring type
Tool set with various mounting/spare parts for
SONOKIT installation
T11
S11
S12
T12
Operating instructions
Article No.
Description
SITRANS FUS060
• English
A5E01204521
• German
A5E02123845
SITRANS FUS080
• English
A5E03059912
• German
A5E31628428
SITRANS F US SONOKIT 2-path
• English
A5E02445496
• German
A5E02554972
This device is shipped with a Quick Start guide and a CD containing further SITRANS F US literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Please use online Product selector to get latest
updates. Product selector link:
www.pia-portal.automation.siemens.com
3/280
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONOKIT (with FUS060 or FUS080)
■ Flowmeter SONOKIT accessories and spare parts
Accessories
Potting kit for SONO 3200 terminal housing
Description
Article No.
Potting kit for terminal box of SONO 3200 transducers for IP68/NEMA 6P (not for Ex sensors)
FDK:085L2403
3
Tools for SONO 3200 transducers and SONOKIT
Description
Article No.
Extraction tool for replacement of SONO 3200 O-ring transducers under pressure and for hot-tapping
(working conditions: typically water, max. 40 bar and max. 60 °C (max. 580 psi and max. 140 °F))
For transducer length:
• Up to 160 mm (6.3")
FDK:085B5333
• Up to 230 mm (9.1")
FDK:085B5335
Angle measurement tool for SONOKIT
FDK:085B5330
Hot-tap drilling tool for SONOKIT, the extraction tool is required, max. pressure 40 bar (580 psi)
FDK:085B5392
Alignment tool for SONOKIT (typically for hot-tapping)
For use on pipe sizes in the range DN 300 to DN 1200.
FDK:085B5393
Description
Article No.
Alignment rods-set for DN 100 ... 650 (4" ... 26"),  = 25 mm, L = 500 mm, 3 pcs.
A5E02609214
Alignment rods-set for DN 700 ... 1900 (28" ... 76"),  = 25 mm, L = 500 mm, 6 pcs.
A5E02609215
Alignment rods-set for DN 2000 ... 3000 (80" ... 120"),  = 25 mm, L = 500 mm, 10 pcs.
A5E02609216
Spanner key for tranducer mounting type SONO 3200 O-ring type
A5E02609218
Tool set with various mounting/spare parts for SONOKIT installation
A5E02609219
Siemens FI 01 · 2016
3/281
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONOKIT (with FUS060 or FUS080)
Cable connection boxes
(For the connection of individual transducer cables with the
FUS060 transducer cables)
Article No.
Description
Junction box for coaxial cable
3
• IP65 metal box for 2 coaxial
cables
FDK:085B1360
• IP65 metal box for 4 coaxial
cables
FDK:085B1361
• IP65 EEx e plastic box for
2 coaxial cables, no ATEX
approval
FDK:085B1362
• IP65 EEx e plastic box for
4 coaxial cables, no ATEX
approval
FDK:085B1363
Spare parts
Transducer SONO 3200 spare parts, complete transducer with ½"-NPT cable glands
Approval Temperature range Length
Article No.
[°C (°F)]
[mm (inch)]
TransMaterial Gasket
ducer type
Pressure Terminal
rating
housing
O-ring
316 SS
O-ring
PN 40
Plastic PA 6.6
-20 … +100
(-4 ... +212)
160 (6.3)
A5E00839476
O-ring
316 SS
O-ring
PN 40
316 SS
-20 … +2001)
(-4 ... +392)
160 (6.3)
A5E00839435
O-ring
316 SS
O-ring
PN 40
Plastic PA 6.6
-20 … +100
(-4 ... +212)
230 (9.41)
A5E00839477
O-ring
316 SS
O-ring
PN 40
316 SS
-20 … +2001)
(-4 ... +392)
230 (9.41)
A5E00839437
1)
316 SS housing for -20 ... +200 °C (-4 ... +392 °F) media temp. but cable glands only for -20 ... +100 °C (-4 ... +212 °F) ambient temp.
Transducer SONO 3200 spare parts, complete transducer with M20 cable glands
Approval Temperature range Length
Article No.
[°C (°F)]
[mm (inch)]
TransMaterial Gasket
ducer type
Pressure Terminal
rating
housing
O-ring
316 SS
O-ring
PN 40
Plastic PA 6.6
-20 … +100
(-4 ... +212)
160 (6.3)
FDK:085B5454
O-ring
316 SS
O-ring
PN 40
316 SS
-20 … +2001)
(-4 ... +392)
160 (6.3)
FDK:085B5455
O-ring
316 SS
O-ring
PN 40
Plastic PA 6.6
-20 … +100
(-4 ... +212)
230 (9.41)
FDK:085B5458
O-ring
316 SS
O-ring
PN 40
316 SS
Ex d2)
-20 … +200
(-4 ... +392)
160 (6.3)
FDK:085B5452
O-ring
316 SS
O-ring
PN 40
316 SS
Ex i3)
-10 … +200
(14 ... 392)
160 (6.3)
A5E00836462
O-ring
316 SS
O-ring
PN 40
316 SS
-20 … +2002)
(-4 ... +392)
230 (9.41)
FDK:085B5459
1)
316 SS housing for -20 ... +200 °C (-4 ... +392 °F) media temp. but cable glands only for -20 ... +100 °C (-4 ... +212 °F) ambient temp.
2)
ATEX (Ex) IIC 2G Ex d IIC T3-T6 Gb
3)
For systems with FUS060 ATEX IIC 2G Ex dem [ia/ib] T6/T4/T3
Transducer SONO 3200 spare parts, transducer terminal housing with M20 cable glands
Type
Article No.
Material: PA 6.6, Temperature range: -20 … +100 °C (-4 ... +212 °F)
FDK:085B5501
Material: AISI 316, Temperature range: -20 … +200 °C (-4 ... +392 °F)
FDK:085B5504
Material: AISI 316, Ex
d1),
Temperature range: -20 … +200 °C (-4 ... +392 °F)
Material: AISI 316, Ex i2), Temperature range: -10 … +200 °C (14 ... 392 °F)
1)
ATEX (Ex) IIC 2G Ex d IIC T3-T6 Gb
2)
For systems with FUS060 ATEX IIC 2G Ex dem [ia/ib] T6/T4/T3
3/282
Siemens FI 01 · 2016
FDK:085B5505
A5E00835255
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONOKIT (with FUS060 or FUS080)
Transducer SONO 3200 spare parts, transducer terminal housing with ½"-NPT cable glands
Type
Article No.
Material: PA 6.6, Temperature range: -20 … +100 °C (-4 ... +212 °F)
A5E00839460
Material: AISI 316, Temperature range: -20 … +200 °C (-4 ... +392 °F)
A5E00839427
Transducer SONO 3200 spare parts transducer body with insert as well as insert only
Temperature range [°C (°F)]
Gasket
Length [mm (inch)]
Article No.
-20 … +200 (-4 ... +392)
O-ring (FFKM O-ring material)1)
160 (6.3)
FDK:085B1406
-20 … +200 (-4 ... +392)
O-ring (FKM 602 O-ring material)2)
160 (6.3)
FDK:085B5510
-20 … +200 (-4 ... +392)
O-ring
230 (9.41)
FDK:085B5511
1)
2)
3
Chemical resistant O-ring material. Body specially for Ex-approved transducers.
Body specially for standard transducers.
Temperature range [°C (°F)]
Length [mm (inch)]
Article No.
-20 … +200 (-4 ... +392)
160 (6.3)
FDK:085B1419
-20 … +200 (-4 ... +392)
230 (9.41)
FDK:085B1420
Transducer SONO 3200 gasket
Type
Pressure rating Material
Gasket O-ring (3 pcs. for O-ring transducers) PN 40
FKM
Temperature range
[°C (°F)]
Article No.
-20 … +200
(-4 ... +392)
FDK:085B1089
Cables for SONOKIT SONO 3200 transducers with FUS060
Description
Length [m (ft)]
Article No.
Coaxial cable for FUS060, (75 , max. 70 ºC (158 ºF), black PVC)
(2 pcs.)
3 (9.84)
A5E00875101
15 (49.21)
A5E00861432
30 (98.43)
A5E01278662
60 (196.85)
A5E01278682
90 (295.28)
A5E01278687
120 (393.70)
A5E01278698
3 (9.84)
A5E00875105
15 (49.21)
A5E00861435
30 (98.43)
A5E01196952
Description
Length [m (ft)]
Article No.
Coaxial cable for FUS080, (75 , max. 70 ºC (158 ºF), black PVC)
(2 pcs.)
15 (49.21)
A5E02478541
30 (98.43)
A5E02478751
High temp. coaxial cable for FUS060; with 0.3 m brown PTFE high temp.
transducer part, max. 200 °C (392 °F) and black PVC transmitter part
with SMB plug, max. 70 ºC (158 ºF); (impedance 75 )
(2 pcs.)
Cables for SONOKIT SONO 3200 transducers with FUS080
Siemens FI 01 · 2016
3/283
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONOKIT (with FUS060 or FUS080)
Transducer holder for SONOKIT SONO 3200 transducers
Type/
description
Temperature range
[°C (°F)]
• 160 mm (6.3") stainless steel
45°, DN 100 … DN 150
(4" ... 6")
FDK:085L1103
-20 ... 100
(-4 ... +212)
A5E02246304
• 160 mm (6.3") carbon steel
45°, DN 100 … DN 150
(4" ... 6")
FDK:085L1102
black PA
plastic,
cable Ø
5 ... 13 mm
(1 pc.)
½" NPT gray -20 ... 100
PA plastic, (-4 ... +212)
cable
Ø 5 ... 9 mm
(1 pc.)
A5E02246309
½" NPT
-40 ... 100
crome(-40 ... +212)
plated
brass, cable
Ø 5 ... 9 mm
(1 pc.)
A5E02246258
Ex i
M20 stain- -25 ... 200
(-13 ... +392)
less steel,
cable
Ø 4 ... 6 mm
(1 pc.)
A5E02246194
1-path (each incl. 1 pc.)
3
SONO 3200 cable glands
Article No.
Description
• 230 mm (9.1") for concrete
FDK:085L1107
pipe 60°, DN 600 … DN 2400
(24" ... 96")
• 160 mm (6.3") stainless steel
60°, DN 200 … DN 2400
(8" ... 96")
FDK:085L1105
• 160 mm (6.3") carbon steel
60°, DN 200 … DN 2400
(8" ... 96")
FDK:085L1104
2-path (each incl. 1 pc.)
• 230 mm (9.1") for concrete
FDK:085L1111
pipe 60°, DN 600 … DN 3000
(24" ... 120")
• 160 mm (6.3") stainless steel
60°, DN 200 … DN 3000
(8" ... 120")
FDK:085L1109
• 160 mm (6.3") carbon steel
60°, DN 200 … DN 3000
(8" ... 120")
FDK:085L1108
The other transducer holder parts are either completely in stainless steel for the concrete and stainless steel pipes
(AISI 316L/1.4404 or similar). For carbon pipes the part welded
onto the pipe is in carbon steel (St.37 or similar). Thread part is
stainless steel (AISI 316L/1.4404 or similar).
Mounting plate for SONOKIT SONO 3200 transducers
Article No.
Description
1-path (each incl. 1 pc.)
• Stainless steel plate, 45°,
DN 100 … DN 150 (4" ... 6")
FDK:085L1113
• Carbon steel plate, 45°,
DN 100 … DN 150 (4" ... 6")
FDK:085L1112
• Stainless steel plate, 60°,
FDK:085L1115
DN 200 … DN 2400 (8" ... 96")
• Carbon steel plate, 60°,
FDK:085L1114
DN 200 … DN 2400 (8" ... 96")
2-path (each incl. 1 pc.)
• Stainless steel plate, 60°,
DN 200 … DN 3000
(8" ... 120")
FDK:085L1119
• Carbon steel plate, 60°,
DN 200 … DN 3000
(8" ... 120")
FDK:085L1118
The mounting plates are either in stainless steel
(AISI 316L/1.4404 or similar) or carbon steel (St.37 or similar).
3/284
Siemens FI 01 · 2016
Appr Article No.
Ex d A5E02246311
M20 stain- -60 ... 180
(-76 ... +356)
less s
teel, cable
Ø 5 ... 8 mm
(1 pc.)
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONOKIT (with FUS060 or FUS080)
■ Schematics
1
Xi
4
Path 1
Sensor
1
4 1A
1A
2B
1B
2A
1
2B
4
Path 2
1A
1B
2A
2B
3
Sensor
1
2A
4
Electrical connection of SITRANS FUS060 and SONOKIT 2-path. Max. 30 m transducer cable length for sizes  DN 3000.
Track 1
1
1B
4
Sensor
1A
1B
1
4 1A
1A
2B
1B
2A
Electrical connection of SITRANS FUS060 and SONOKIT 1-path
2A 1A
2A 1A
2A 1A
2A 1A
2A 1A
1B 2B
2A 1A
1B 2B
1B 2B
1A
1B 2B
1B 2B
1B
1A
2A
1B 2B
1B
2B
Electrical connection of SITRANS FUS080 and SONOKIT 2-path
Electrical connection of SITRANS FUS080 and SONOKIT 1-path
Siemens FI 01 · 2016
3/285