Monitoring, Controlling and Switching with SIRIUS Relays One range for every application siemens.com/relays Answers for industry. The full-range SIRIUS relay portfolio Every engineer knows that he must be completely up to date when it comes to controls, load feeders and drives. However, with coupling, control and monitoring relays, the search among the various suppliers becomes time-consuming. This is now a thing of the past because we have combined all these products in a single range: SIRIUS®. This makes it easy for you to select the optimum product and guarantees a top priceperformance ratio. The highlights at a glance SIRIUS relays – one range for every application • Broad applicability comprehensive portfolio Our range of SIRIUS relays comprises everything required for motor feeder applications. With maximum ease and comfort. From a single source. Whether compact timing or reliable monitoring relays, particularly narrow coupling relays, plug-in relays, low-noise power relays or interface converters – our relay range is the most complete and comprehensive portfolio on the market. We offer relays for each and every application. Moreover, all SIRIUS relays offer outstanding ease of operation. Take a closer look at our portfolio and convince yourself. You will be surprised. • User-friendly easy operation • Multi-functional flexibly applicable relays • Practice-oriented graded for customized performance • Open communication with the control thanks to IO-Link interface • Excellent cost/performance ratio Use of SIRIUS relays L1 L2 L3 Coupling relay SIMATIC S7-1200 Monitoring relay Line U, Asym ... Control / feedback Timing relay Load IS, IP, cos φ Motor °C, rpm ... Time-delayed control 2 Contents SIRIUS timing relays: Full control of all time sequences Timing relays 3RP20 / 25 and 7PV15 timing relays for DIN rail mounting 6 – 7 2 – 3* Function modules 3RA2811 / 12 / 16 function modules for mounting on 3RT2 contactors 8 4* Time-delayed auxiliary switches 3RA2813 / 14 / 15 time-delayed auxiliary switches for mounting on 3RT2 contactors 9 5* SIRIUS monitoring relays: Perfect protection of machines and systems 3UG451 / 461 / 463 monitoring relays for line and single-phase voltage monitoring – as 3UG481 / 483 also for IO-Link 10 6* 3RR21/22 monitoring relays for direct mounting on contactors for multi-phase current monitoring – as 3RR24 also for IO-Link 12 7* 3UG4621 / 4622 / 4641 monitoring relays for single-phase current monitoring, power factor and active current monitoring – as 3UG4822 / 4841 also for IO-Link 13 8* 3UG4625 monitoring relays for residual current monitoring – as 3UG4825 also for IO-Link 14 9* 3UG458 monitoring relays for insulation monitoring 15 9* 3UG4501 monitoring relays for level monitoring 16 10* 3UG4651 monitoring relays for speed monitoring – as 3UG4851 also for IO-Link 17 10* Thermistor motor protection 3RN1 thermistor motor protection to protect against overheating 18 11* Temperature monitoring relays 3RS10 / 3RS11 temperature monitoring relays (analog-adjustable) 20 12* 3RS10 / 11 / 20 / 21 temperature monitoring relays (digital-adjustable) – as 3RS14 / 15 also for IO-Link 21 13* 3TX700 / 701 coupling relays in narrow, compact design with relay output 22 14* 3TX700 coupling relays in narrow, compact design with semiconductor output 23 15* 3RS18 coupling relays in industrial enclosure 24 15* LZS coupling relays with plug-in relays 25 16* Interface converters 3RS17 interface converters (standard signal and universal converters) 26 18* Power relays 3TG10 power relays for high performance with minimum dimensions 28 19* Monitoring relays SIRIUS coupling relays: Perfect interaction of control and system Coupling relays * Technical annex 3 SIRIUS Monitoring Relays for IO-Link Reliable monitoring and protection SIRIUS relays from Siemens offer maximum machine and system protection and now also communicate with the control level thanks to IO-Link. The new SIRIUS relays for IO-Link monitor line quality, current values, voltages, speeds and temperatures with the known reliability while supporting an even broader application area. Your advantages • Precise monitoring of electrical, mechanical and temperature values • Reliable protection of motors and system components • Realization of simple autonomous temperature control tasks (2-point, 3-point control) • Connection to the control level via IO-Link • Central fault diagnostics and localization SIRIUS speaks IO-Link With the SIRIUS monitoring relays for IO-Link, you opt for maximum flexibility: In addition to the unchanged autonomous monitoring function, measured values and data can be directly transferred to the control via IO-Link. Also parameterization can either be realized locally or via IO-Link. The SIRIUS relays for IO-Link are thus fully integrated in Totally Integrated Automation, our open system architecture for integrated automation. Moreover, you will benefit from considerably eased device replacement – thanks to data comparison and automatic re-parameterization via parameter servers. • Eased commissioning and maintenance • Efficient energy management with SIRIUS 3UG48: Support of the data formats defined in the PROFIenergy profile SIRIUS monitoring relays for IO-Link: • SIRIUS 3RR24: 3-phase current monitoring directly integrated in the load feeder • SIRIUS 3UG48: Monitoring of electrical and mechanical parameters: Voltage, current, power factor and speed • SIRIUS 3RS14 / 15: Monitoring of temperatures Unique consistency: IO-Link integrated in Totally Integrated Automation IO-Link engineering SIMATIC S7-PCT Visualization: SIMATIC HMI WinCC S7-300 / S7-400 control PROFINET/PROFIBUS ET 200S with IO-Link Master SIMATIC ET 200eco PN with IO-Link Master IO-Link SIRIUS 3RA6 compact starters K20 IO-Link module SIRIUS 3RS14 / 3RS15 relays SIRIUS 3RA2 load feeders with 3RA27 function modules SIRIUS 3UG48 relays Actuators Control cabinet installation 4 SIRIUS 3RB24 overload relays Further field devices IO-Link sensors Field installation Standard sensors 5 3RP20 / 25 and 7PV15 Timing Relays for DIN rail mounting Electronic timing relays are used for all time-delayed switching processes in control, starting, protection and regulation circuits. Thanks to their elaborate operating concept and space-saving, compact design, the 3RP20 / 25 timing relays are ideal timing devices for manufacturers of industrial control cabinets, power distribution boards and controls. With their narrow design, the 7PV15 timing relays are particularly suitable for applications in heaters, fans, air-conditioning systems and compressors. Application ON-delay • Interference pulse suppression (gating of interference pulses) • Successive motor starting to prevent mains overloads OFF-delay • Generation of overtravel functions after disconnection of the control voltage (e.g. fan run-on) • Successively delayed disconnection of motors, fans, etc., for targeted system shutdown Wye(star)-delta • Motor start-up with reduced starting current in wye (star) circuit • Switchover to delta operation for full motor power after adjustable time • Short switchover break to prevent interphase short circuit with delayed contactor switching Multifunction • Maximum flexibility: one device with wide-range supply for all time functions Watchdog function • Monitoring of cyclic events Your advantages • The right construction type for any application • Compact range for all applications thanks to multifunctional devices and wide voltage range • Short cycle times and bounce-free and wear-free switching thanks to timing relays with semiconductor output • Significant logistical advantages thanks to versions with wide voltage and wide time setting ranges • DIN rail mounting and disassembly without tools • Cadmium-free relay contacts • Recyclable, halogen-free enclosure 3RP20 / 25 timing relays • Documentation of the set function on the multifunctional timing relay via label sets (3RP20) or adhesive film (3RP25) • Sealable cover for safeguarding of set parameters 7PV15 timing relays • Minimum variance: One design both for power distribution boards and control cabinets • Compliance with EMC requirements for residential areas • Switchover break with wye(star)-delta adjustable from 50 ms to 1 sec, for optimum adjustability to the application 6 3RP20/25 and 7PV15 Timing Relays Applications of the 3RP20 / 25 and 7PV15 ranges 3RP20 – the timing relay in contactor design: Recommended for small distance between DIN rails and/or low installation depths, e.g. in control boxes 3RP25 – the premium range for all applications in industrial-standard width 22.5 mm and spacesaving 17.5 mm: for variable use thanks to versions with 1 or 2 relays, screw and spring-type terminals, hard gold-plated contacts, positively driven operation, etc. 7PV15 – the version for standard applications: Narrow and cost-favorable, both for control cabinets and power distribution boards 7 3RA2811 / 12 / 16 Function Modules 3RA2811 / 12 / 16 Function Modules for mounting on 3RT2 contactors The function modules facilitate the mounting of starters and contactor assemblies for direct-on-line and wye(star)-delta starting. They comprise all important control functions required for the respective feeder – e.g. timing and electric interlocking function. The function modules, which act as timing relays, can be rapidly and easily mounted on SIRIUS contactors – without laborious wiring. They support contactor switching both with ON- and OFF-delay. Application ON-delay • Time-delayed starting of multiple drives for example reduces the summation starting current and thus prevents the occurrence of line voltage dips or cable overloads (cascade circuit) OFF-delay • Time-controlled disconnection of a drive’s control signal after a start pulse, e.g. with gate control, follow-up ventilation Function modules for wye(star)-delta start • Switchover during drive starting, e.g. switchover of large fans from wye (star) to delta as current-limiting measure • Fixed switchover break of 50 ms for short-circuit protection • Universal use thanks to wide voltage and large setting range of the wye (star) start time Wye(star)-delta function module: Easy and fault-free mounting on 3RT2 contactors thanks to plug-in technology Your advantages • Reduction of control circuit wiring • Prevention of wiring faults • 24 – 240 V AC/DC wide voltage range for control supply voltage and contactor coil control • Reduced testing costs • Realization of control-independent timing functions • Space savings in the control cabinet (compared to a separate timing relay) • No additional protective circuit required (integrated varistor) • Automatic preference circuit with wye(star)-delta function modules for further reduction of current peaks • Assembly of wye(star)-delta starters, including timing function and electric interlocking, without additional wiring • Approvals in accordance with IEC, CCC, UL and CSA standards 8 for mounting on 3RT2 contactors The electronically delayed auxiliary switches for mounting onto contactors are dimensioned for contactor coil voltages from 24 to 240 V AC/DC (wide voltage). Auxiliary switches for control and status signals are employed especially for the switching of very small signals for electronic applications. They are used for example for pump or fan run-on similar to OFF-delay timing relays or the delayed switch-on of a gate drive. Both the electrical and mechanical connection are realized by simply snapping the device on and locking it. A varistor is integrated in the time-delayed auxiliary switch for the attenuation of switching overvoltages in the contactor coil. Application ON-delay • For example for the delayed readiness signaling of a drive after start-up with centrifugal mass OFF-delay • Generation of run-on functions for fans or pumps after disconnection of the control voltage Your advantages • Flexible use for all contactor control supply voltages in the 24 – 240 V AC/DC range • Selectable outputs 1 NO + 1 NC or 1 CO • All modules with 24 – 240 V AC/DC wide voltage in the auxiliary circuit • Integrated electric interlocking and factory-integrated varistor (protective circuit) – easy configuration • Plug-on function modules for connection without tools • High setting accuracy thanks to selectable time ranges • Reduced variance – only 1 module for sizes S00 and S0 • Add-on modules for reduced wiring and space savings Differences SIRIUS 3RA2811 / 12 / 16 and 3RA2813 / 14 / 15 • Unlike DIN rail mounted timing relays, 3RA2811 / 12 / 16 function modules do not feature any relay outputs. They represent timing relays which are directly mounted on 3RT2 contactors. Instead of the contactors, the function modules are controlled which then switch the contactors below via direct contact with the contactor coil. • With 3RA2813/14/15 time-delayed auxiliary switches, the 3RT2 contactor is controlled which then switches on or off instantaneously. The auxiliary switch mounted on the contactor responds to this via voltage tap on the contactor coil and switches the relay outputs with a time delay. 9 3RA2813 / 14 / 15 Time-Delayed Auxiliary Switches 3RA2813 / 14 / 15 Time-Delayed Auxiliary Switches 3UG451 / 461 / 463 and 3UG481 / 483 Monitoring Relays 3UG451 / 461 / 463 and 3UG481 / 483 Monitoring Relays for line and voltage monitoring The 3UG4 monitoring relays provide a maximum degree of protection for machines and systems. They facilitate the early detection of line and voltage faults, allowing for their rectification before any consequential damage can occur. IO-Link Application Typical applications can be derived from the table on page 11. Scan the QR code and watch a video! Your advantages Configuration of 3-phase line monitoring • Can be used in all global networks from 160 to 600 V AC without separate auxiliary voltage thanks to wide voltage range • Variably adjustable to overshoot, undershoot or window monitoring • Freely parameterizable delay times and RESET response • Narrow width for all versions • Permanent display of ACTUAL value and type of line fault with digital versions • Automatic direction of rotation correction thanks to differentiation between power system fault and incorrect phase sequence 10 3UG4 monitoring relay Phase failure Contactor Phase asymmetry, voltage Direction of rotation Possible system fault Phase sequence • Direction of rotation of the drive Phase failure • Fuse tripping 3UG451 / 461 / 463 and 3UG481 / 482 Monitoring Relays Measured variable • Control supply voltage failure • Single-phase operation of a motor with corresponding overheating Phase asymmetry • Motor overheating due to asymmetric voltages or phase failure • Detection of asymmetrically loaded supply systems • Phase failure detection despite regenerative feedback Undervoltage • Increased motor current with respective overheating • Unintended device reset • Mains failure, particularly with battery supply • Threshold value switch for analog signals from 0 to 10 V Overvoltage • System protection against destruction caused by supply overvoltages • System switch-on upon reaching a certain voltage • Threshold value switch for analog signals 0 to 10 V 11 3RR21/22 and 3RR24 Monitoring Relays for direct mounting on contactors for multi-phase current monitoring The 3RR2 monitoring relays are used not only for monitoring motors or other loads, but additionally also facilitate optimum current monitoring of the entire system or driven process. This for example allows for the early detection and signaling of load shedding or motor overloads. The 3RR2 monitoring relay for current monitoring is directly integrated in the load feeder. It is simply plugged onto the contactor. IO-Link 3RR2 Monitoring Relays Scan the QR code and watch a video! Your advantages Application • Monitoring for current overshoot and undershoot • Monitoring of open circuit • Monitoring of no-load operation and load shedding, e.g. in the event of a torn V-belt or no-load operation of a pump • Monitoring of overload, e.g. caused by excessive loading of conveyor belts or cranes • Monitoring of the functionality of electric loads such as heaters • Monitoring of wrong phase sequences on mobile equipment such as compressors or cranes • Monitoring of high-impedance faults to ground, e.g. due to damaged insulation or moisture Current monitoring directly in the main circuit 12 • Direct mounting on 3RT2 contactors, i.e. no additional wiring overhead in the main circuit • Optimally matched to the technical characteristics of 3RT2 contactors, no separate current transformers required • 2- or 3-phase current monitoring, apparent or active current monitoring • Display of ACTUAL values and status messages • Easy determination of threshold values by means of direct reference to actually measured values under setpoint load • Only one device is required for motor monitoring along the entire torque curve • Monitoring for cable breakage, phase failure, phase sequence, residual current as well as motor blocking 3UG4621 / 4622 / 4641 and 3UG4822 / 4841 Monitoring Relays for single-phase current, power factor and active current monitoring The 3UG4 relays for current, active power and active current monitoring are ideally suited for monitoring the load of motors and the functionality of electronic loads. These devices detect signs of wear and faults early on, thereby for example facilitating the timely implementation of maintenance measures to prevent system failures. IO-Link Current monitoring • Overload monitoring • Underload monitoring close to the rated torque • Monitoring of the functionality of electric loads • Wire breakage monitoring • Energy management (phase current monitoring) • Threshold value switch for analog signals from 4 to 20 mA Power factor and active current monitoring • No-load monitoring • Underload monitoring in the lower power range • Overload monitoring Scan the QR code and watch a video! • Easy power factor monitoring in networks for the control of compensation systems • Energy management • Cable breakage between control cabinet and motor Current and active power depending on the motor load Rule of thumb: The power factor changes significantly below the rated load; the current increases disproportionally above the rated load. Your advantages • Reduced stock-keeping thanks to wide-voltage versions • Variably adjustable to overshoot, undershoot or window monitoring • Freely parameterizable delay times and RESET response • Permanent display of ACTUAL value and type of fault cos φ • Setting of monitoring limits on the basis of real measured values • Real rms value measurement Current monitoring • Only two versions from 2 mA to 10 A • Applicable for frequencies with 40–500 Hz AC and DC Power factor and active current monitoring Motor load The active current Ires indicates a linear correlation between the motor load and the measured value over the entire measuring range. • Global use thanks to wide voltage from 90 to 690 V AC • Monitoring of smaller single-phase motors with a no-load current below 0.5 A • One device for motor monitoring, from no-load to overload • Voltage-independent monitoring of the motor load 13 3UG4621 / 4622 / 4641 and 3UG 4822 / 4841 Monitoring Relays Application 3UG4625 and 3UG4825 Monitoring Relays for residual current monitoring Residual-current monitoring relays are used for monitoring residual currents that can result in insulation problems in plants due to humidity or severe contamination. By using the 3UG4625 or 3UG4825 residual-current monitoring relay in combination with a 3UL23 summation current transformer, such hazards can be eliminated. Thanks to adjustable limit or warning threshold values, the relay issues a warning before the limit value is reached and switches off reliably when the limit value is exceeded after a certain delay time. The 3UG4825 monitoring relays have an IO-Link interface for digital transfer of measured values to the control. 3UG4625 and 3UG4825 Monitoring Relays IO-Link Application Monitoring of systems prone to residual currents, e.g. caused by: • Dust deposits or humidity • Porous cables and lines • Capacitive residual currents Your advantages • Can be used worldwide thanks to a wide voltage range from 24 to 240 V AC/DC • Measuring range from 30 mA to 40 A • Variably adjustable threshold values for warning and disconnection • Freely parameterizable delay times and RESET response and connectable fault memory • Permanent display of the actual value and fault diagnostics via display • High level of flexibility and space saving through installation of the transformer outside the control cabinet • All diagnostics data are now available in the control 14 3UG458 Monitoring Relays for insulation monitoring Application Amongst others, IT networks are employed in the following applications: • Emergency power supply systems • Emergency lighting systems • Industrial production plants with high availability requirements (chemical industry, automotive industry, printing industry) • Marine and railway applications • Mobile current generators (airplanes) • Renewable energies, e.g. wind energy and photovoltaic plants • Mining 3UG458 Monitoring Relays Insulation monitoring relays are used for monitoring the insulation resistance between ungrounded single- or three-phase current supplies and a protective conductor. Ungrounded, i.e. isolated networks (IT networks) are always used where high demands are placed on the reliability of the power supply, e.g. emergency lighting systems. After an initial insulation fault it is possible to continue working in safety (single-fault safety). The fault must still be rectified as quickly as possible before a second insulation fault occurs (e.g. according to DIN VDE 0100-410). For this purpose insulation monitoring relays are used which constantly measure the resistance to ground of the phase conductor and the neutral conductor, reporting a fault immediately if insulation resistance falls below the set value. Your advantages • Devices for AC and DC systems • All devices with wide supply voltage range • Direct connection to networks with line voltages up to 690 V AC and 1000 V DC via voltage reducer module • With AC networks: Frequency range 15 ... 400 Hz • Monitoring for line breakage • Monitoring for faulty settings • Application safety thanks to integrated system start after start-up • Reset and test option (via button on the front or control contact) • Rapid response times thanks to new predictive measuring principle 15 3UG4501 Monitoring Relays for level monitoring 3UG4 monitoring relays also detect non-electrical variables. Our 3UG4501 level monitoring relays thus ensure reliable 1- and 2-point controls and alarms in case of overflow or dry running – according to a simple principle: almost all liquids are conductive. This is utilized for monitoring levels. If the probes are immersed in the liquid, current flows – if the probes fall dry, no current flows. 3UG4501 Monitoring Relays Scan the QR code and watch a video! Application • 1- and 2-point level control • Overflow protection • Dry running protection • Leakage monitoring Your advantages • Can be used worldwide thanks to wide voltage range from 24 to 240 V AC/DC • Individually trimmable 2- and 3-pole wire electrodes for easy mounting from the top/bottom • Bow electrodes for lateral installation for higher filling levels and minimum space requirements • Flexibly adjustable to various conductive liquids through analog setting of the sensitivity from 2 to 200 kΩ • Compensation of wave movements thanks to tripping delay times from 0.1 to 10 seconds • Selectable feed or discharge function 1- and 2-point level monitoring, overflow protection Product kΩ This method is applicable with very many liquids and substances. Prerequisite: Specific resistance < 200 kΩ 16 Product kΩ Buttermilk 1 Natural water 5 Fruit juice 1 Wastewater 5 Vegetable juice 1 Starch solution 5 Milk 1 Oil 10 Soup 2.2 Condensed water 18 Beer 2.2 Soap foam 18 Coffee 2.2 Jams 45 Ink 2.2 Jellies 45 Saltwater 2.2 Sugar solution 90 Wine 2.2 Whisky 220 Distilled water 450 3UG4651 and 3UG4851 Monitoring Relays for speed monitoring The 3UG4651 and 3UG4851 speed monitoring relays monitor the setpoint speed of motors, shafts or driven wheels for overshoot or undershoot. Implementing a period measurement, they monitor the pulses delivered per rotation from the sensors. In addition, the relays are suitable for all functions requiring the monitoring of a continuous pulse signal, e.g. belt operation and scan time monitoring or bypass control. The 3UG4851 monitoring relays have an IO-Link interface for digital transfer of measured values to the control. Scan the QR code and watch a video! Application • Slip/breakage of a belt drive • Load shedding • Standstill monitoring (no operator protection) • Transport item monitoring for completeness Your benefits • Can be used worldwide thanks to wide voltage range from 24 to 240 V AC • Variably adjustable to overshoot, undershoot or window monitoring • Freely parameterizable delay times and RESET response • Permanent display of ACTUAL values or type of fault • Use of up to 10 sensors per rotation with extremely slowly rotating motors • Connection option for 2- or 3-conductor sensors and sensors with mechanical switching or electronic output • Integrated auxiliary voltage for sensor Speed monitoring example with 3UG4651 Without enable input With enable input 17 3UG4651 and 3UG4851 Monitoring Relays IO-Link 3RN1 Thermistor Motor Protection for protection against overheating Thermistor motor protection relays provide decisive benefits in cases in which current-dependent protection using either a circuit breaker or an overload relay is not the perfect solution: In specific cases, often as a result of external effects, overheating can occur without being detected by the thermal image in the circuit breaker or overload relay. Examples for this include heavy-duty starting (e.g. centrifuges), operation with frequency converters or frequent switching, braking operations or when cooling is restricted, e.g. due to accumulated dirt. Application 3RN1 Thermistor Motor Protection • Protection of motors against overheating, particularly with heavy-duty starting, braking operation, frequent switching or insufficient cooling • “Warning and disconnection” function based on two sensor circuits with different response temperatures for responding prior to disconnection (additional cooling, load reduction, etc.) • Multiple motor protection with only one device, e.g. with conveyor lines comprising multiple motors which are to be disconnected jointly Your advantages • Direct measuring of the motor winding temperature Characteristics for type A thermistor sensor • Device/terminal labeling acc. to DIN EN 50005 for “normal” switching relays and for overload protection systems 4000 R • Relays with hard gold-plated contacts for application under difficult conditions 1330 550 • Indication of wire breakage and short circuit in the sensor circuit via LED 250 20 –20 °C 0 18 • Only one device for all motor power ratings TNF-20 TNF TNF+15 T TNF-5 TNF+5 • Version with safe isolation up to 300 V in accordance with DIN/VDE 0106 as well as version with bistable relays for special cases • ATEX approval for gases and dust 19 3RN1 Thermistor Motor Protection 3RS10 / 3RS11 Temperature Monitoring Relays analog-adjustable The 3RS10 / 3RS11 temperature monitoring relays are specialized in the measuring of temperatures in solid, liquid and gaseous media. The temperature is detected via sensors inside the medium, then evaluated by the device and monitored for overshoot or undershoot of the limit temperatures. Depending on the parameterization, the output relay switches on or off upon reaching the threshold values. Application 3RS10 / 3RS11 Temperature Monitoring Relays • Motor and system protection • Control cabinet temperature monitoring • Frost monitoring • Temperature limits for process parameters, e.g. in the packing industry or galvanizing systems • System and machine control, e.g. heating, air-conditioning and ventilation systems, solar collectors, heat pumps or hot water supply systems • Bearing and gear oil monitoring • Coolant monitoring Your advantages • All devices with galvanic isolation, exception: 24 V AC/DC • Easy operation via rotary potentiometer • Selectable hysteresis • Selectable operating principle for devices with two threshold values 20 3RS10 / 11 / 20 / 21 and 3RS14 / 15 Temperature Monitoring Relays digital-adjustable Suitable for temperature measuring in solid, liquid and gaseous media, these relays monitor temperatures for overshoot and undershoot or within a specific operating range (window function). The devices also present a good alternative to temperature controllers in the low-end range. IO-Link • System and environmental protection • Temperature limits for process parameters, e.g. in the packing industry or galvanizing systems • Temperature monitoring for heat generation plants • Monitoring of exhaust gas temperatures • System and machine control, e.g. heating, air-conditioning and ventilation systems, solar collectors, heat pumps or hot water supply systems • Motor, bearing and gear oil temperature monitoring • Coolant monitoring Your advantages • Easy operation without complicated menu guidance • 3-digit LED display for indication of the temperature • Connection option for resistance sensors in 2- or 3-conductor technology • Galvanic isolation with wide voltage supply versions • Availability of versions in °C and °F (switchover from °C to °F possible with IO-Link versions) Scan the QR code and watch a video! Type “E” Type “J” Type “K” Type “N” Voltage in μV Characteristics for thermocouples Voltage in mV Characteristics of most important resistance temperature sensors Type “R” Type “S” Type “B” Resistance in Ω Type “T” Temperature in °C Temperature in °C Temperature in °C Characteristics for sensor types J, K, T, E and N Characteristics for sensor types S, R, and B 21 3RS10 / 11 / 20 / 21 and 3RS14 / 15 Temperature Monitoring Relays Application 3TX700 / 701 Coupling Relays in narrow, compact design with relay output The 3TX70 coupling relays are available in two designs for space-optimized application in the control cabinet. On the one hand, the coupling relays with a width of only 6.2 mm require only minimum space on the DIN rail. On the other hand, a range of coupling relays with minimum depth / height is available for assembly in the control cabinet with minimum line spacing or in flat control boxes. Application • Galvanic isolation • Voltage conversion, e.g. from 24 V DC to 230 V AC • Signal amplification • Contact multiplication • General relay controls • Overvoltage and EMC protection of controls Your advantages with 3TX7002 / 03 (compact enclosure) and 3TX7004 / 05 (6.2 mm width) • Soldered relays (not pluggable) for increased contact reliability • Operating range from 0.7 to 1.25 US 3TX700 / 701 Coupling Relays • Temperature range up to 60 °C with 24 V DC • Protective circuit integrated in the input • Connection comb and cable for bridging of identical potentials • Simpler commissioning thanks to manual-0automatic switch Your advantages with 3TX7014 and 3TX7015 (6.2 mm width) • Plug-in relays for rapid replacement with permanent wiring • Reduced wiring time thanks to wire entry and clamping via the front • Reduced mounting time thanks to tested complete devices • Availability of individual relays as spare parts • Device version with hard gold-plated contacts for high contact reliability Coupling relays as input or output coupler 110 V AC 230 V AC Pushbuttons Position switches 22 Actuators Electronic control I/O devices 24 V DC Input coupling links Input Output 24 V DC 110 V AC 230 V AC Output coupling links Motor contactors 3TX700 Coupling Relays in narrow, compact design with semiconductor output Coupling modules are available with conventional relays or with semiconductor outputs. Compared to relays, the coupling modules with semiconductor output offer significant advantages: The electronic components are extremely reliable and have a very long service life (see diagram). The input coupler combines both advanced technology and price advantages. With regard to output couplers, the decision as to whether to opt for ”relay or semiconductor“ should be based on the requirements regarding switching capacity and switching cycles. If a relay has to be replaced just once during the entire service life of a machine, then a semiconductor coupler has already paid off. Application • Galvanic isolation, voltage conversion • Switching of DC loads • Switching of capacitive loads • Overvoltage and EMC protection of controls Your advantages with 3TX700 with semiconductor output • Very long electrical service life • Maximum contact reliability • High DC switching capacity • Short switching times • Easy bridging of identical potentials thanks to suitable accessories • High number of switching cycles • Noise-free switching Use of semiconductor couplers Service life comparison High Output Average 24 V DC Semiconductor Motor protection Failure probability Input Low Beginning wear with mechanical components Failure probability with electronic components Service life Electronic coupling modules have a significantly longer service life than electromechanical ones. 23 3TX700 Coupling Relays Actuators Electronic control 3RS18 Coupling Relays in industrial enclosure The 3RS18 relay coupling set standards: With a wide voltage range extending from 24 V to 240 V AC/DC they are an absolute highlight in the coupling market. We offer you in this range devices in the field-proven 22.5 mm industrial enclosure with one, two or three changeover contacts – with screw-type or spring-type terminals and in combined voltage or wide voltage with hard gold-plated contacts for particularly high contact reliability even with low currents. Thanks to the field-proven industrial enclosure you benefit – as with our timing relays – from a user-friendly connection method with permanent wiring. Two conductors per clamping point can be connected. Application • Wherever electronically optimized contacts are required and devices with wide voltage are used • Predestined for inputs and outputs on PLC thanks to hard gold-plated contacts Your advantages • One product for all voltages • Cost savings thanks to reduced variance 3RS18 Coupling Relays • Particularly high contact reliability even with low currents 24 LZS Coupling Relays with plug-in relays Plug-in relay couplers are available both as complete devices and as individual modules for self-assembly or spare parts requirements. The range is divided into three types: RT, PT and MT. Application • As coupling relay for galvanic isolation between field and input and outputs of electronic controls • Contact multiplication • Switching of small loads • As potential transfer switch Your advantages • Wiring without tools and vibrationproof connection thanks to innovative push-in spring-type terminals • Base with logical isolation for easy wiring • Tested AC-15 and DC-13 switching capacity • Available coil voltages: 24 V DC, 24 V AC, 115 V AC, 230 V AC • Hard gold-plated contacts for optimum interaction with electronic controls Configuration information 1 Wiring bracket for push-in spring-type terminal base and 2 Screw terminal base 1 2 The test lever of the PT relay does not feature a latching mechanism. If the test lever is pressed further until a movement of 90° is reached, two small snap-in lugs break off and the test lever can be set to latching. When using plug-in relays with voltages of 60 Hz AC, the lower response value has to be increased by 10 %, the power loss decreases slightly. Types LZS:PT 2, 3 or 4 CO contacts AC-1: 12/10/6 A Width: 28 mm LZS:MT 3 CO contacts AC-1: 10 A Width: 38 mm 25 LZS Coupling Relays LZS:RT 1 or 2 CO contacts AC-1: 16/8 A Width: 15.5 mm 3RS17 Interface Converters Standard signal and universal converters Interface converters are mainly used for the galvanic isolation and conversion of analog signals. Sensors / actuators and controls generally have different power supply units and therefore require galvanic isolation in the signal circuit. This is either realized in the control or via an interface converter. Signal conversion is for example required when a voltage signal has to be transferred as a current signal over a long distance or when the output of a sensor and the input of a control are incompatible. A further application is supported by the realized frequency outputs. Here, the input signal is converted into a proportional frequency. As a result, analog signals can be processed with digital inputs. This is important in cases where the control does not feature a slot for an analog input or when all slots are already assigned, e.g. with retrofits. Application • Galvanic isolation of analog signals • Conversion of analog signals • Conversion of analog signals into a frequency • Conversion of non-standardized signals into standardized signals • Overvoltage protection of analog inputs Your advantages • Minimum width • Easily adjustable universal converters • Converters with frequency output • Full calibration of all areas • Integrated range, the ideal solution for every application • Integrated manual-automatic switch with setpoint generator • Short-circuit-proof outputs • Protection against damage caused by faulty wiring up to 30 V Passive converters 3RS17 Interface Converters Passive converters do not require any supply voltage as their required energy is supplied via the analog signal. 2-way isolation 3-way isolation With 2-way isolation, the input is electrically isolated from the output. The “zero potential” of the supply voltage is the same as the reference potential for the analog output signal. For 3-way isolation, each circuit is electrically separated from the other circuits, i.e. input, output, and supply voltage do not have equipotential bonding. IN U,I OUT Vcc U,I,F 2-way isolation 26 IN U,I U,I,F Vcc 3-way isolation OUT 3RS17 Interface Converters 27 3TG10 Power Relays for high performance with minimum dimensions The 3TG10 power relays are the ideal solution for all applications requiring small, low-noise relays or contactors at low costs. The power relays are suitable for basic controls and particularly for use in large-scale series devices and controls. They are ideal for applications which require only one auxiliary contact and no overload relay – and place increased requirements upon switching capacity, switching voltage and service life. Application • Domestic appliances and installations • Hoisting systems: Small elevators, elevating platforms • Building technology, hum-free application in building systems, e.g. in hospitals Your advantages • Any mounting position, hum-free • Safe isolation • Screw-type or plug-in connection • Integrated auxiliary switch • AC-3 power: 4 kW / 400 V • Operating current Ie/AC-1: 20 A / 400 V • Inrush current per phase: 90 A • Integrated overvoltage damping • Narrow width of only 36 mm Configuration information 3TG10 Power Relays With a 20 A load on the three main current paths, the following applies with I > 10 A for the fourth current path: Permissible ambient temperature 40 °C 28 29 Scan the QR code for further information Further information: siemens.com/relays Siemens AG Industry Sector Control Components and Systems Engineering P.O. Box 23 55 90713 FÜRTH GERMANY Subject to change without prior notice 07/14 Article No. E20001-A1800-P302-V2-7600 Dispo 27601 21/52900 WS 0814 2.0 Printed in Germany © Siemens AG 2014 The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks and product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. Technical Data Monitoring, Controlling and Switching with SIRIUS Relays siemens.com/relays Answers for industry. SIRIUS Zeitrelais SIRIUS Timing Relays Overview of SIRIUS timing relays 3RP25 industrial design Function Number and type of contacts 3RP20 contactor design 7PV15 Insta design 3RA28 SIRIUS 3RT2 contactor mounting 3RT1916/26 SIRIUS 3RT1 contactor mounting ON-delay 1CO,2CO1),1NO (SC) 1CO, 2CO1) 1CO, 2CO 1CO, 1 NO/1NC, 1NO (SC) 1NO/1NC, 1NO (SC) OFF-delay with control signal 1CO, 2CO1), 1NO (SC) 1 CO, 2 CO1) 1 CO, 2 CO 1CO, 1NO/1NC, 1NO (SC) 1NO/1NC, 1NO (SC) OFF-delay without control signal Additive ON-delay with control signal 1 CO, 2 CO 1CO,2CO1),1NO (SC) – 1 CO 1 CO 1 CO 1 CO, 1 NO/1 NC 2 NO, 1 NC Additive ON-delay, instantaneous OFF with control signal ON-/OFF-delay with control signal 2 CO1), 1 NO (SC) 1 CO – – – – – 1CO, 2CO1),1NO(SC) 1 CO, 2 CO1) 2 CO Wye(star)-delta function with run-on tiime 3 NO – – – – – – Wye(star)-delta function 2 NO, 2 CO 2 CO 2 NO 2 NO 2 NO Flashing, non-symmetrical, starting with break (clock generator) Flashing, symmetrical, starting with break 1 CO, 1 NO (SC) – 1 CO – – 1CO, 2CO1), 1NO (SC) 1 CO, 2 CO1) 1 CO, 2 CO – – Flashing, symmetrical, starting with break 2 CO , 1 NO (SC) – – – – Passing make contact 1CO, 2CO1), 1NO (SC) 1 CO, 2 CO1) 1 CO, 2 CO – – Passing break contact with control signal (retrotriggerable interval relay with deactivated control signal) Pulse-shaping with control signal (passing make contact with control signal, not retrotriggerable) Fixed pulse after ON-delay 1CO, 2CO1), 1NO (SC) 1 CO, 2 CO1) 1 CO – – 1CO, 2CO1), 1NO (SC) 1 CO, 2 CO1) 1 CO, 2 CO – – – – 2 CO Pulse-delay relay (settable pulse and pulse delay, pulse length 500 ms) Pulse-delay relay with control signal (settable pulse and pulse delay, pulse length 500 ms) Retrotriggerable interval relay with activated control signal (watchdog) Non-volatile time relay, positive passing make contact 2 CO1), 1 NO (SC) – – – – – – 2 CO1), 1 NO (SC) – – – – 2 CO1), 1 NO (SC) – – – – 1 CO, 2 CO – – – – 1) 1) Can be used both as two CO contacts switched in parallel and as one CO contact switching instantaneously + one CO contact switching with time delay. For further information refer to Catalog IC 10 and the SIRIUS 3RP25 timing relay simulator: www.siemens.com/relais CO = changeover contact NO = normally open contact SC = semiconductor NC = normally closed contact 2 3RP25 electronic timing relays in 17.5 mm and 22.5 mm industrial enclosure Function 13 functions Contacts Time range Rated control supply voltage Us Article No. 1 CO 0.05 s – 100 h AC/DC 24 V 3RP2505- AB30 1 CO 0.05 s – 100 h AC/DC 12 – 240 V 3RP2505- AW30 1 NO (SC) 0.05 s – 100 h AC/DC 12 – 240 V 2 CO 0.05 s – 100 h AC/DC 24 V 3RP2505- BB30 2 CO 0.05 s – 100 h AC 400 – 440 V 3RP2505- BT20 2 CO 0.05 s – 100 h AC/DC 12 – 240 V 1 CO 0.5 s – 10 s AC/DC 12 – 240 V 3RP2505- BW30 1 CO 1 s – 30 s AC/DC 12 – 240 V 1 CO 5 s – 100 s AC/DC 12 – 240 V 1 CO 0.05 s – 100 h AC/DC 12 – 240 V 2 CO 0.05 s – 100 h AC/DC 24 V 2 CO 0.05 s – 100 h AC/DC 12 – 240 V 1 NO (SC) 0.05 s – 240 s AC/DC 12 – 240 V 1 CO 1 CO 0.05 s – 100 h 0.05 s – 600 s AC/DC 12 – 240 V AC/DC 24 V 1 CO 0.05 s – 600 s AC/DC 12 – 240 V 2 CO 0.05 s – 600 s AC/DC 24 V 2 CO 0.05 s – 600 s AC/DC 12 – 240 V Clock generator 1 CO 0.05 s – 100 h AC/DC 12 – 240 V Wye(star)-delta function (SD) w. runon time Wye(star)-delta function 3 NO AC/DC 12 – 240 V 3RP2560- SW30 2 NO 1 s – 20 s (SD), 30 s – 600 s run-on time 1 s – 20 s (SD) AC 200 – 240V / 380 – 440 V 2 NO 1 s – 20 s (SD) AC/DC 12 – 240 V 3RP2574- NM20 2 NO 3 s – 60 s (SD) AC 200 – 240 V / 380 – 440 V 2 NO 3 s – 60 s (SD) AC/DC 12 – 240 V 27 functions ON-delay OFF-delay with control signal OFF-delay without control signal, non-volatile, passing make contact 3RP2505- CW30 3RP2511- AW30 3RP2512- AW30 3RP2513- AW30 3RP2525- AW30 3RP2525- BB30 3RP2525- BW30 3RP2527- EW30 3RP2535- AW30 3RP2540- AB30 3RP2540- AW30 3RP2540- BB30 3RP2540- BW30 3RP2555- AW30 3RP2574- NW30 3RP2576- NM20 3RP2576- NW30 1 Screw terminals Spring-type terminals 2 3RP20 electronic timing relays in SIRIUS design 45 mm Function 8 functions Contacts Time range Rated control supply voltage Us Article No. 1 CO 0.05 s – 100 h AC/DC 24/AC 100 – 127 V 1 CO 0.05 s – 100 h AC/DC 24/AC 200 – 240 V 16 functions1) 2 CO 0.05 s – 100 h AC/DC 24 – 240 V ON-delay 1 CO 0.05 s – 100 h AC/DC 24/AC 100 – 127 V 1 CO 0.05 s – 100 h AC/DC 24/AC 200 – 240 V 1) The 16 functinos correspond to the 8 functins of the multifunctinal timing relays with one CO contact. In addition it can be set whether both CO outputs should respond with a delay or whether the second CO should switch immediately. 3RP2005- AQ30 3RP2005- AP30 3RP2005- BW30 3RP2025- AQ30 3RP2025- AP30 1 Screw terminals Spring-type terminals 2 Electronic 7PV15 timing relays in 17.5 mm enclosure for industry and infrastructure Function Contacts Time range Rated control supply voltage Us Article No. 7 functions 1 CO 0.05 s – 100 h AC/DC 12 – 240 V 7PV1508-1AW30 2 CO 0.05 s – 100 h AC/DC 12 – 240 V 7PV1508-1BW30 1 CO 0.5 s – 10 s AC/DC 24/AC 100 – 127 V 7PV1512-1AQ30 1 CO 0.05 s – 1 s AC/DC 24/AC 100 – 127 V 7PV1511-1AP30 1 CO 0.5 s – 10 s AC/DC 24/AC 200 – 240 V 7PV1512-1AP30 1 CO 5 s – 100 s AC/DC 24/AC 100 – 127 V 7PV1513-1AQ30 1 CO 5 s – 100 s AC/DC 24/AC 200 – 240 V 7PV1513-1AP30 1 CO 0.05 s – 100 h AC/DC 12 – 240 V 7PV1518-1AW30 1 CO 0.05 s – 100 h AC/DC 90 – 127 V 7PV1518-1AJ30 1 CO 0.05 s – 100 h AC/DC 180 – 240 V 7PV1518-1AN30 OFF-delay with control signal 1 CO 0.05 s – 100 h AC/DC 12 – 240 V 7PV1538-1AW30 OFF-delay without control signal 1 CO 0.05 s – 100 s AC/DC 12 – 240 V 7PV1540-1AW30 Clock generator 1 CO 0.05 s – 100 h AC/DC 12 – 240 V 7PV1558-1AW30 Wye(star)-delta function 1 NO + 1 NO 0.05 s – 100 h AC/DC 12 – 240 V 7PV1578-1BW30 ON-delay 3 SIRIUS 3RP20/25 Timing Relays and7PV15 Timing Relays SIRIUS 3RP20 / 3RP25 Timing Relays and 7PV15 Timing Relay SIRIUS 3RA2811 / 12 / 16 Function Modules SIRIUS 3RA2811 / 12 / 16 Function Modules 3RA2811 / 12 function modules for direct start for mounting on 3RT2 contactors with semiconductor output for size S00 and S0 Function Time range Rated control supply voltage Us Article No. ON-delay 0.05 s – 100 s AC/DC 24 – 240 V OFF-delay with control signal 0.05 s – 100 s AC/DC 24 – 240 V 3RA2811- CW10 3RA2812- DW10 1 Screw terminals Spring-type terminals 2 3RA2816 function modules for wye(star)-delta start Wye-delta function 0.5 s – 60 s 3RA2816-0EW20 AC/DC 24 – 240 V No wiring required! 3RT1916-2 / 26-2 electronic timing relays for mounting on 3RT1 contactors ON-delay 0.05 s – 1 s 0.5 s – 10 s AC/DC 24 – 66 V 3RT19 6-2CG11 3RT19 6-2CG21 AC/DC 90 – 240 V 3RT19 6-2CH11 5 s – 100 s ON-delay 0.05 s – 1 s 3RT19 6-2CG31 0.5 s – 10 s 3RT19 6-2CH21 5 s – 100 s OFF-delay with control signall 0.05 s – 1 s 3RT19 6-2CH31 AC/DC 24 – 66 V 3RT19 6-2DG11 0.5 s – 10 s 3RT19 6-2DG21 5 s – 100 s OFF-delay with control signal 0.05 s – 1 s 3RT19 6-2DG31 AC/DC 90 – 240 V 3RT19 6-2DH11 0.5 s – 10 s 3RT19 6-2DH21 5 s – 100 s 3RT19 6-2DH31 Size S00 1 Size S0 – S3 2 3RT1916-2 / 26-2 plug-on timing relays for wye(star)-delta start Function Time range Rated control supply voltage Us Contacts Article No. Wye(star)-delta function 0.5 s – 30 s AC/DC 24 V 1NO delayed + 3RT19 6-2GJ51 1NO instanataneous AC/DC 100 – 127 V 1NO delayed + 1NO instantaneous AC/DC 200 – 240 V 1NO delayed + 1NO instantaneous Size S00 1 Size S0 – S* 3RT19 6-2GC51 3RT19 6-2GD51 2 *S3 to S12, dependent on exact MLFB (see Catalog IC 10) 4 SIRIUS 3RA2813 / 14 / 15 Time-Delayed Auxiliary Switches SIRIUS 3RA2813 / 14 /15 Time-Delayed Auxiliary Switches 3RA2813 / 14 / 15 electronically delayed auxiliary switches for mounting on 3RT2 contactors for size S00 and S0, integrated varistor Function Rated control supply voltage Us Time range Contacts Article No. ON-delay AC/DC 24 – 240 V 0.05 s – 100 s 1 CO ON-delay AC/DC 24 – 240 V 0.05 s – 100 s 1 NO + 1 NC 3RA2813- AW10 OFF-delay with control signal AC/DC 24 – 240 V 0.05 s – 100 s 1 CO OFF-delay with control signal AC/DC 24 – 240 V 0.05 s – 100 s 1 NO + 1 NC Off-delay without control signal AC/DC 24 – 240 V 0.05 s – 100 s 1 CO OFF-delay without control signal AC/DC 24 – 240 V 0.05 s – 100 s 1 NO + 1 NC 3RA2813- FW10 3RA2814- AW10 3RA2814- FW10 3RA2815- AW10 3RA2815- FW10 1 Screw terminals Spring-type terminals 2 3RT1916-2 / 26-2 electronically delayed auxiliary switches for mounting on 3RT1 contactors, integrated varistor ON-delay ON-delay ON-delay OFF-delay without control signal OFF-delay without control signal OFF-delay without control signal OFF-delay with control signal AC/DC 24 V AC/DC 100 – 127 V AC/DC 200 – 240 V AC/DC 24 V AC/DC 100 – 127 V AC/DC 200 – 240 V AC/DC 24 V 0.05 s – 1 s 1 NO + 1 NC 0.5 s – 10 s 1 NO + 1 NC 5 s – 100 s 1 NO + 1 NC 0.05 s – 1 s 1 NO + 1 NC 0.5 s – 10 s 1 NO + 1 NC 5 s – 100 s 1 NO + 1 NC 0.05 s – 1 s 1 NO + 1 NC 0.5 s – 10 s 1 NO + 1 NC 5 s – 100 s 1 NO + 1 NC 0.05 s – 1 s 1 NO + 1 NC 0.5 s – 10 s 1 NO + 1 NC 5 s – 100 s 1 NO + 1 NC 0.05 s – 1 s 1 NO + 1 NC 0.5 s – 10 s 1 NO + 1 NC 5 s – 100 s 1 NO + 1 NC 0.05 s – 1 s 1 NO + 1 NC 0.5 s – 10 s 1 NO + 1 NC 5 s – 100 s 1 NO + 1 NC 0.5 s – 10 s 1 CO 3RT19 6-2EJ11 3RT19 6-2EJ21 3RT19 6-2EJ31 3RT19 6-2EC11 3RT19 6-2EC21 3RT19 6-2EC31 3RT19 6-2ED11 3RT19 6-2ED21 3RT19 6-2ED31 3RT19 6-2FJ11 3RT19 6-2FJ21 3RT19 6-2FJ31 3RT19 6-2FK11 3RT19 6-2FK21 3RT19 6-2FK31 3RT19 6-2FL11 3RT19 6-2FL21 3RT19 6-2FL31 3RT1916-2LJ51 OFF-delay with control signal AC/DC 100 – 127 V 0.5 s – 10 s 1 CO 3RT1916-2LC51 OFF-delay with control signal AC/DC 200 – 240 V 0.5 s – 10 s 1 CO 3RT1916-2LD51 Size S00 Size S0 – S* 1 2 *S3 to S12, dependent on exact MLFB (see Catalog IC 10) 5 SIRIUS 3UG4 Monitoring Relays 3UG451, 3UG461 monitoring relays for line monitoring Phase sequence Phase failure Asymmetry Hysteresis Undervoltage Overvoltage N-cond. monitoring Delay times Contacts Rated control Article No. supply voltage Us1) 1 CO AC 160 – 260 V1) 3UG4511- AN20 AC 320 – 500 V1) 3UG4511- AP20 AC 420 – 690 V1) 3UG4511- AQ20 2 CO AC 160 – 260 V1) 3UG4511- BN20 AC 320 – 500 V1) 3UG4511- BP20 AC 420 – 690 V1) 3UG4511- BQ20 Yes Condit.2) – – – – – – Yes Yes 10 % – – – – – 1 CO Yes Yes 20 % 5 % 80 % of Us – – OFF-delay 0.1 s – 20 s 2 CO AC 160 – 690 V1) 3UG4512- AR20 AC 160 – 690 V1) 3UG4512- BR20 AC 160 – 690 V1) 3UG4513- BR20 Selectable Yes 0 or 1 – 20 V 160 – 690 V – 5 – 20 % – ON- and OFF-delay 0.1 s – 20 s 2 CO AC 160 – 690 V1) 3UG4614- BR20 Selectable Yes Via thre- 1 – 20 V 160 – 690 V 160 – 690 V – shold values 0.1s – 20 s each for Umin and Umax 1 CO each for Umin and Umax AC 160 – 690 V1) 3UG4615- CR20 Selectable Yes Via thre- 1 – 20 V 90 – 400 V against N shold values 0.1 s – 20 s each for Umin and Umax 1 CO each for Umin and Umax AC 90 – 400 V1) against N Autom. correction Yes 0 or 1 – 20 V 160 – 690 V 160 – 690 V – 5 – 20 % OFF-delay 0.1 s – 20 s AC 160 – 690 V1) 3UG4617- CR20 1 CO each for line faults and phase sequence Autom. correction Yes 0 or 1 – 20 V 90 – 400 V 5 – 20 % against N OFF-delay 0.1 s – 20 s AC 90 – 400 V1) 1 CO each for line faults and against N phase sequence 2 CO 90 – 400 V against N 90 – 400 V against N Yes Yes 3UG4616- CR20 3UG4618- CR20 3UG463 monitoring relays for single-phase voltage monitoring Measuring range Hysteresis Contacts Rated control supply voltage Us1) Delay time Article No. 22.5 mm width, all devices digital-adjustable and with LC display, connectable fault memory, simultaneous monitoring for voltage overshoot and undershoot over the entire measuring range AC/DC 0.1 – 60 V 0.1 – 30 V 1 CO 0.1 s – 20 s AC/DC 24 V 3UG4631- AA30 AC/DC 24 – 240 V AC/DC 10 – 600 V 0.1 – 300 V 1 CO 0.1 s – 20 s 3UG4631- AW30 AC/DC 24 V 3UG4632- AA30 AC/DC 24 – 240 V AC/DC 17 – 275 V 0.1 – 150 V 1 CO 0.1 s – 20 s 3UG4632- AW30 Intrinsic supply 3UG4633- AL30 3UG4815 / 16 monitoring relays for line and three-phase voltage monitoring ONdelay IO-Link SIRIUS 3UG4 Monitoring Relays 22.5 mm width, 3UG4614 to 3UG4618 digital-adjustable, with fault memory and LC display Stabilization time Tripping delay time Hysteresis Contacts Adjustable monitoring range Article No. 22.5 mm width, adjustable via IO-Link or locally, monitoring of phase sequence, phase failure, phase asymmetry, overvoltage and undervoltage 3 phases 3 phases + N-cond. failure – Voltage: 0 – 20 V OFF OFF Asymmetry: 0.1 – 999.9 s 0.1 – 999.9 s 0 – 20 % 1 CO 1 Q in SIO mode AC 160 – 690 V1) 3UG4815- AA40 AC 90 – 400 V1) to N 3UG4816- AA40 AC 10 – 600 V 3UG4832- AA40 3UG4832 monitoring relays for single-phase voltage monitoring 22.5 mm width, adjustable via IO-Link or locally, monitoring of overvoltage and undervoltage 1 phase OFF 0.1 – 999.9 s – OFF OFF 0.1 – 999.9 s 1 – 300 V 1 CO 1 Q in SIO mode 1) Absolute limit values 2) Return voltage due to coupling of the individual phases The 3UG4511 device is not able to detect phase failures reliably. Loads connected in the three-phase network, e.g. motor windings, lamps, transformers, ensure the individual phases‘ connection. Due to this network coupling, a return voltage is always present on the device terminal of the failed phase. 6 1 Screw terminals Spring-type terminals 2 SIRIUS 3RR2 Monitoring Relays 3RR21 monitoring relays Size Measuring range Hysteresis Contacts ONdelay Rated control supply voltage Us Article No. All devices analog-adjustable, closed-circuit principle, 2-phase current monitoring, apparent current monitoring, tripping delay 0 – 30 s, automatic or manual RESET S00 1.6 – 16 A 6.25 % of the threshold value 1 CO 0 – 60 s AC/DC 24 V AC/DC 24 – 240 V S0 4 – 40 A 6.25 % of the threshold value 1 CO 0 – 60 s AC/DC 24 V S2 8 – 80 A 6,25 % of the threshold value 1W 0 – 60 s AC/DC 24 V AC/DC 24 – 240 V AC/DC 24 – 240 V 3RR2141- AA30 3RR2141- AW30 3RR2142- AA30 3RR2142- AW30 3RR2143- AA30 3RR2143- AW30 Screw terminals Spring-type terminals for sizes S00, S0 Spring-type terminals for size S2 1 2 3 3RR22 monitoring relays Size Measuring range Hysteresis Contacts ONdelay Restart delay Rated control supply voltage Us Article No. All devices digital-adjustable, LC display, open- or closed-circuit principle, 3-phase current monitoring, active current or apparent current monitoring, delay time 0 – 30 s, automatic or manual RESET, phase sequence monitoring, residual current monitoring, blocking current monitoring, separate settings for warning and alarm thresholds 1.6 – 16 A 0.1 – 3 A 1 CO 1Q 0 – 99 s 0 – 300 min AC/DC 24 V S0 4 – 40 A 0.1 – 8 A 1 CO 1Q 0 – 99 s 0 – 300 min AC/DC 24 – 240 V AC/DC 24 V S2 8 – 80 A 0,2 – 16 A 1W 1Q 0 – 99 s 0 – 300 min AC/DC 24 V AC/DC 24 – 240 V AC/DC 24 – 240 V 3RR2241- FA30 3RR2241- FW30 3RR2242- FA30 3RR2242- FW30 3RR2243- FA30 3RR2243- FW30 Screw terminals Spring-type terminals for sizes S00, S0 Spring-type terminals for sizes 1 2 3 SIRIUS 3RR2 Monitoring Relays S00 3RR24 monitoring relays IO-Link Size Measuring range Hysteresis Contacts ON delay Rated control supply voltage Us Restart delay Article No. All devices adjustable locally and via IO-Link, LC display, open- or closed circuit principle, 3-phase current monitoring, active current or apparent current monitoring, delay time 0 – 30 s, automatic or manual RESET, current asymmetry monitoring, phase sequence monitoring, residual current monitoring, blocking current monitoring, operating hours counter, switching cycle counter, separate settings for warning and alarm thresholds S00 1.6 – 16 A 0.1 – 3 A S0 4 – 40 A 0.1 – 8 A S2 8 – 80 A 0,2 – 16 A 1 CO 1 Q (in SIO mode) 1 CO 1 Q (in SIO mode) 1 CO 1 Q (in SIO mode) OFF 0.1 – 999.9 s OFF 0.1 – 999.9 s OFF 0,1 – 999,9 s OFF 0.1 – 300 min OFF 0.1 – 300 min OFF 0,1 – 300 min DC 24 V 3RR2441- AA40 DC 24 V 3RR2442- AA40 DC 24 V 3RR2443- AA40 Screw terminals Spring-type terminals for sizes S00, S0 Spring-type terminals for size S2 1 2 3 Adapter for stand-alone mounting for separate mounting of the monitoring relays on DIN rails Size Article No. S00 3RU2916-3A 01 S0 S2 3RU2926-3A 01 3RU2936-3AA01 A Screw terminals Spring-type terminals C 7 SIRIUS 3UG4 Monitoring Relays 3UG4621 / 22 monitoring relays for single-phase current monitoring Measuring range Hysteresis Contacts ONdelay Tripping delay Rated control supply voltage Us Article No. 22.5 mm width, all devices digital-adjustable and with LC display, connectable fault memory, simultaneous monitoring for current overshoot and undershoot over the entire measuring range AC/DC 3 – 500 mA 0.1 – 250 mA 1 CO 0.1 – 20 s 0.1 – 20 s AC/DC 24 V1) 3UG4621- AA30 AC/DC 24 – 240 V2) AC/DC 0.05 – 10 A 0.01 – 5 A 1 CO 0.1 – 20 s 0.1 – 20 s 3UG4621- AW30 AC/DC 24 V1) 3UG4622- AA30 AC/DC 24 – 240 V2) No galvanic isolation. Load supply voltage 24 V. 2) Galvanic isolation between control circuit and measuring circuit. Load supply voltage for safe isolation max. 300 V, for simple separation max. 500 V. 1) 3UG4622- AW30 1 Screw terminals Spring-type terminals 2 3UG4641 monitoring relays for power factor and active current monitoring Measuring range Measuring for power factor range for active current Ires Hysteresis with power factor Hysteresis with active current Contacts ON-delay time Tripping delay time Rated control Article No. supply voltage Us1) 22.5 mm width, device digitally adjustable and with LC display, connectable fault memory, simultaneous power factor and active current monitoring over the entire measuring range 0.1 – 0.99 (PF) 1) 0.2 – 10.0 A 0.1 (PF) 0.1 – 2.0 A 1 CO + 1 CO 0 – 99 s 0.1 – 20.0 s Absolute limit values AC 90 – 690 V1) 3UG4641- CS20 1 Screw terminals Spring-type terminals 2 3UG4822 monitoring relays for single-phase current monitoring IO-Link Hysteresis Contacts ONdelay time Article No. Tripping delay time 22.5 mm width, adjustable via IO-Link or locally, monitoring of overcurent and undercurrent, scaling factor for considering external 1 A / 5 A instrument transformer adjustable 0.05 – 10 A OFF 0.01 – 5 A 1 CO 1 Q in SIO mode OFF 0.1 – 999.9 s OFF 0.1 – 999.9 s 3UG4822- AA40 3UG4841 monitoring relays for power factor and active current monitoring 22.5 mm width, adjustable via IO-Link or locally, monitoring of phase sequence, phase failure, phase asymmetry, overvoltage and undervoltage cos phi: 0.1 – 0.99 cos phi: OFF/0.1 – 0.20 Current: 0.2 – 10 A Current: OFF/0.1 – 3 A 1 CO 1 Q in SIO mode OFF 0.1 – 999.9 s OFF 0.1 – 999.9 s 3UG4841- CA40 1 Screw terminals Spring-type terminals 2 Current and power factor dependent on the motor load Rule of thumb: The power factor changes significantly below the rated load; the current increases disproportionally above the rated load. cos φ SIRIUS 3UG4 Monitoring Relays Measuring range Motor load The active current Ires indicates a linear correlation between the motor load and the measured value over the entire measuring range. 8 SIRIUS 3UG4 Monitoring Relays 3UG4624 monitoring relays for residual current monitoring Measurable current Control supply Control supply voltage at DC voltage at 60 Hz at AC rated rated value value Control supply Adjustable response delay voltage at 50 Hz at AC rated time value Switching Adjustable response value hysteresis current Article No. 22.5 mm width, digitally adjustable and with LC display, permanent self-monitoring, monitoring of a warning threshold and limit value overshoot, for 3UL23 residual current transformer 0.01–43 A 0.03–40 A 0–50 % 0–20 s 24–240 V 24–240 V 24–240 V 3UG4625- CW30 1 Screw terminals Spring-type terminals 2 3UG4825 monitoring relays for residual current monitoring IO-Link Measurable current Adjustable response Switching hysteresis Adjustable response Control supply voltage delay time at DC value rated value current Article No. 22.5 mm width, digitally adjustable and with LC display, permanent self-monitoring, monitoring of a warning threshold and limit value overshoot, for 3UL23 residual current transformer 0.01–43 A 0.03–40 A 0–50 % OFF 0.1–999.9 s 24 V 3UG4825- CA40 1 Screw terminals Spring-type terminals 2 3UL23 residual current transformers for residual current monitoring Max. rated current per phase Max. connectable conductor cross- Article No. section of terminal SIRIUS 3UG4 Monitoring Relays Diameter of bushing opening Detection of residual currents in machines and systems 3UL2302-1A 35 mm 85 A 2.5 mm2 55 mm 150 A 3UL2303-1A 80 mm 225 A 3UL2304-1A 110 mm 400 A 3UL2305-1A 140 mm 500 A 210 mm 630 A 3UL2306-1A 3UL2307-1A 4 mm2 3UG4581 monitoring relays for insulation monitoring for non-grounded AC networks Rated line voltage Un Output relay System leakage capacitance Meas. range Ue Rated control supply voltage Us Cable break Article No. detection in the measuring range AC 0 – 400 V max. 10 µF 1 – 100 kΩ AC/DC 24 – 240 V – 1 CO 3UG4581-1AW30 3UG4582 / 83 monitoring relays for insulation monitoring for non-grounded DC and AC voltage networks AC 0 – 250 V, DC 0-300 V max. 10 µF 1 CO 1 – 100 kΩ AC/DC 24 – 240 V AC 0 – 400 V, DC 0 – 600 V 2) max. 20 µF 2 CO or 1 CO + 1 CO adjustable 1 – 100 kΩ, 2 – 200 kΩ for 2nd limit value, adjustable AC/DC 24 – 240 V Yes 3UG4582-1AW30 Yes adjustable 3UG4583-1CW30 Series module for 3UG4583 for expansion of the line voltage range to max. 690 V AC and 1000 V DC 3UG4983-1A Covers for monitoring relays for insulation monitoring 2) Application Version Article No. For 3UG4581, 3UG4582 Sealable, transparent cover 3UG4981-0C For 3UG4583 Sealable, transparent cover 3UG4983-0C With 3UG49 83-1A series module also suitable for insulation monitoring of IT networks up to 690 V AC and 1000 V DC. 9 SIRIUS 3UG4 Monitoring Relays Überwachungsrelais 3UG4501 for 1- and 2-point level monitoring of conductive liquids Sensitivity Contacts Tripping delay Width 2–200 kΩ 1 CO 0.5–10 s 22.5 mm Rated control supply voltage Us AC/DC 24 V Article No. 3UG4501- AA30 AC/DC 24 – 240 V 3UG4501- AW30 Probes for level monitoring, max. operating temperature 90 °C, max. operating pressure 10 bar Description Cable connection Number of poles Article No. Wire electrode, 500 mm long, with teflon insulation 3 x 0.5 mm , 2 m 3-pole 3UG3207-3A 2 x 0.5 mm2, 2 m 2-pole 3UG3207-2A Wire electrode for lateral installation 3 x 0.5 mm2, 2 m 2-pole 3UG3207-2B 2 x 0.5 mm2, 2 m 1-pole 3UG3207-1B 2 x 0.5 mm2, 2 m 1-pole 3UG3207-1C 2 Rod electrode, stable 1 Screw terminals Spring-type terminals 2 3UG4651 monitoring relays for monitoring of speed undershoot and overshoot Meas. range pulses / min Contacts ON-delay time Tripping delay Width Rated control supply voltage Us 0.1–2200 (0.0017–36.67 Hz) 1 CO 1–900 s 0.1–99.9 s 22.5 mm AC/DC 24 V AC/DC 24–240 V Article No. 3UG4651- AA30 3UG4651- AW30 1 Screw terminals Spring-type terminals 2 IO-Link SIRIUS 3UG4 Monitoring Relays 3UG4851 monitoring relays for monitoring of speed undershoot and overshoot Meas. range pulses / min Contacts ON-delay time OFF-delay time Hysteresis Article No. Monitoring for speed overshoot and undershoot, scaling factor for consideration of multiple incremental encoders per rotation 0.1 – 2200 1 CO (0,0017 – 36,67 Hz) 1 Q in SIO mode OFF 0.1 – 999.9 s OFF 0.1– 999.9 s OFF 0.1– 99.9 rpm 3UG4851- AA40 1 Screw terminals Spring-type terminals 2 10 SIRIUS 3RN1 Thermistor Motor Protection Thermistor motor protection relays for PTC thermistors (PTCs Type A) All devices except for 24 V AC/DC feature galvanic isolation Version RESET Contacts Rated control supply Article No. voltage Us Compact evaluation devices, 22.5 mm width, monostable, closed-circuit principle, 1 LED Terminal A1 is bridged with the root of the CO contact Automatic 1 CO AC/DC 24 V AC 110 V 3RN1000- AB00 3RN1000- AG00 AC 230 V 3RN1000- AM00 Standard evaluation devices, 22.5 mm width, monostable, closed-circuit principle, 2 LEDs 1 NO + 1 NC AC/DC 24 V AC 110 V 3RN1010- CG00 AC 230 V AC/DC 24 – 240 V 2 CO AC/DC 24 V AC 110 V 2 CO, hard gold-pl. AC/DC 24 V 1 NO + 1 NC AC/DC 24 V AC 110 / 230 V Short-circuit detection in the sensor circuit Manual/remote3) 2 CO AC/DC 24 V AC 110 V AC 230 V Prot. against volt. failure2) Short-circuit detection in the sensor circuit Manual/automatic/ 1 NO + 1 NC remote AC 110 / 230 V Manual/automatic/ 2 CO remote AC 110 V AC/DC 24 V 24 V AC/DC AC 230 V Manual/automatic/ 2 CO remote For bimetal sensors (without short-circuit detection) Manual/remote 3RN1010- BB00 3RN1010- BM00 3RN1010- GB00 3RN1011- CB00 3RN1011- CK00 3RN1011- BB00 3RN1011- BM00 3RN1011- GB00 3RN1012- CB00 3RN1012- CK00 3RN1012- BB00 3RN1012- BG00 2 CO, hard gold-pl. AC/DC 24 V Prot. against volt. failure2), detection and indication of short circuit and wire breakage in the sensor circuit, wide voltage with screw terminals with safe isolation1) 3RN1010- CW00 3RN1011- BG00 2 CO, hard gold-pl. AC/DC 24 V Prot. against volt. failure2) 3RN1010- CM00 3RN1010- BG00 AC 230 V Manual / remote3) 3RN1010- CB00 AC/DC 24 V AC/DC 24 – 240 V 3RN1012- BM00 3RN1012- GB00 3RN1013- BB00 3RN1013-1BW10 3RN1013-2BW00 2 CO, hard gold-pl. AC/DC 24 – 240 V 3RN1013-1GW10 2 CO 3RN1014-1BM00 3RN1013-2GW00 AC 230 V Evaluation units for 2 sensor circuits, warning and disconnection, 22.5 mm width, monostable, closed-circuit principle, 3 LEDs Test/RESET button, prot. against volt. failure2); evaluation circuit for “warning” works with NO contact in closed-circuit principle Manual/automatic/ 1 NO + 1 NC remote AC/DC 24 – 240 V 3RN1022- DW00 Evaluation units for 6 sensor circuits, multi-motor protection, 45 mm width, monostable, closed-circuit principle, 8 LEDs Test / RESET button, prot. against volt. failure2) Manual/automatic/ 1 NO + 1 NC remote AC/DC 24 – 240 V 3RN1062- CW00 Manual/automatic/ 2 CO remote AC/DC 24 – 240 V 3RN1013- BW01 Bistable evaluation units, 22.5 mm width Test / RESET button, prot. against volt. failure2), detection and indication of short-circuit and wire breakage in sensor circuit, bistable version, no tripping on failure of control supply voltage Safe isolation up to 300 V acc. to DIN/VDE 0106, IEC 60947-1 For information on protection against voltage failure see Catalog IC 10 3) Reset using RESET button or interruption of control supply voltage possible 1) 2) 1 Screw terminals Spring-type terminals 2 11 SIRIUS Thermistor Motor Protection 3RN1 Automatic SIRIUS 3RS10 / 3 RS11 Temperature Monitoring Relays 3RS10 / 3RS11 temperature monitoring relays Sensor Function Measuring range Rated control supply voltage Us Article No. Analog-adjustable, 1 sensor, 1 threshold value, 22.5 mm width; analog closed-circuit principle; non-retentive; 1 NO + 1 NC PT100 (resistance sensor) Overshoot – 50 ... + 50 °C AC/DC 24 V AC 110/230 V 0 ... + 100 °C AC/DC 24 V AC 110/230 V 0 ... + 200 °C AC/DC 24 V AC 110/230 V Undershoot –50 ... +50 °C 0 ... + 100 °C 0 ... + 200 °C Type J (thermocouple) Overshoot 0 ... + 200 °C SIRIUS 3RS10 / 3RS11 Temperature Monitoring Relays 0 ... + 600 °C Type K (thermocouple) Overshoot 0 ... + 200 °C 0 ... + 600 °C + 500 ... + 1000 °C 3RS1000- CD00 3RS1000- CK00 3RS1000- CD10 3RS1000- CK10 3RS1000- CD20 AC/DC 24 V 3RS1000- CK20 3RS1010-1CD00 AC 110/230 V 3RS1010-1CK00 AC/DC 24 V 3RS1010-1CD10 AC 110/230 V 3RS1010-1CK10 AC/DC 24 V 3RS1010-1CD20 AC 110/230 V 3RS1010-1CK20 AC/DC 24 V AC 110/230 V 3RS1100- CD20 3RS1100-1CK20 AC/DC 24 V 3RS1100-1CD30 AC 110/230 V 3RS1101-1CK30 AC/DC 24 V 3RS1101-1CD20 AC 110/230 V 3RS1101-1CK20 AC/DC 24 V 3RS1101-1CD30 AC 110/230 V 3RS1101-1CK30 AC/DC 24 V 3RS1101-1CD40 AC 110/230 V 3RS1101-1CK40 AC/DC 24 V 3RS1020-1DD00 AC/DC 24 – 240 V 3RS1020-1DW00 AC/DC 24 V 3RS1020-1DD10 AC/DC 24 – 240 V 3RS1020-1DW10 AC/DC 24 V 3RS1020-1DD20 AC/DC 24 – 240 V AC/DC 24 V 3RS1020- DW20 3RS1030-1DD00 AC/DC 24 – 240 V 3RS1030-1DW00 AC/DC 24 V 3RS1030-1DD10 AC/DC 24 – 240 V 3RS1030-1DW10 AC/DC 24 V 3RS1030- DD20 3RS1030-1DW20 Analog-adjustable for warning and disconnection 2 threshold values), 22.5 mm width; selectable open-/closed-circuit principle; non-retentive; 1 NO + 1 CO PT100 (resistance sensor) Overshoot – 50 ... + 50 °C 0 ... + 100 °C 0 ... + 200 °C Undershoot – 50 ... + 50 °C 0 ... + 100 °C 0 ... + 200 °C AC/DC 24 – 240 V Type J (thermocouple) Overshoot 0 ... + 200 °C AC/DC 24 – 240 V 3RS1120- DD20 3RS1120-1DW20 AC/DC 24 V 3RS1120-1DD30 AC/DC 24 – 240 V 3RS1120-1DW30 0 ... + 200 °C AC/DC 24–240 V 3RS1121-1DW20 0 ... 600 °C AC/DC 24–240 V 3RS1121-1DW30 + 500 ... + 1000 °C AC/DC 24 V 3RS1121-1DD40 0 ... + 600 °C Type K (thermocouple) Overshoot Analog-adjustable evaluation units with one and two threshold values. With analog-adjustable devices, the threshold values and the hysteresis from 2 to 20% are set via a rotary potentiometer. The adjustable hysteresis only applies for threshold 1. For the 2nd threshold a fixed hysteresis of 5 % applies. This product range has been developed for applications for which an adjustment accuracy of ±5 % is sufficient. Suitable sensors are available via www.siemens.com/temperature 12 AC/DC 24 V 1 Screw terminals Spring-type terminals 2 SIRIUS 3RS10 / 11 / 20 / 21 and 3RS14 / 15 Temperature Monitoring Relays 3RS10 / 11 and 3RS20 / 21 temperature monitoring relays Sensor Rated control supply voltage Us AC 50 / 60 Hz Measuring range (Meas. range limit is sensor-dependent) Article No. Digital-adjustable, 1 sensor, 2 threshold values, 45 mm width; 1 CO + 1 CO + 1 NO, storage function possible through external bridge; device parameters are non-volatile –50... +500 °C AC/DC 24 V 3RS1040- GD50 AC/DC 24 – 240 V –58... +932 °F 3RS1040- GW50 AC/DC 24 V 3RS2040- GD50 AC/DC 24 – 240 V Type J, K, T, E, N thermocouple) –99... +999 °C ( 3RS2040- GW50 AC/DC 24 V 3RS1140- GD60 AC/DC 24 – 240 V –99... +1830 °F 3RS1140- GW60 AC/DC 24 V 3RS2140- GD60 AC/DC 24 – 240 V 3RS2140- GW60 Digital-adjustable, 1 sensor, 2 threshold values, 45 mm width; 1 CO + 1 CO + 1 NO, tripping state and device parameters are non-volatile PT100/1000; KTY83/84; NTC (resistance sensor)1) –50... +750 °C Type J, K, T, E, N, R, S, B (thermocouple) –99... +1800 °C AC/DC 24 V 3RS1042- GD70 AC/DC 24 – 240 V 3RS1042- GW70 AC/DC 24 V 3RS1142- GD80 AC/DC 24 – 240 V 3RS1142- GW80 Motor monitoring relays, digitally adjustable for up to 3 sensors, 45 mm width; 1 CO + 1 CO + 1 NO Sensor Number of sensors Measuring range Rated control supply voltage Us Article No. PT100/1000; KTY83/84; NTC (resistance sensor)1) 1 to 3 sensors –50... +500 °C –58... +932 °F AC/DC 24 – 240 V AC/DC 24 – 240 V 3RS1041- GW50 3RS2041- GW50 1) NTC type: B57227-K333-A1 (100 °C: 1,8 kΩ; 25 °C: 32,762 kΩ) 1 Screw terminals Spring-type terminals 2 3RS14 / 15 temperature monitoring relays IO-Link ON-delay time 1) Tripping delay time Hysteresis Contacts Article No. Adjustable monitoring range Monitoring of temperatures for overshoot and undershoot, 45 mm width, 1 CO per limit value, 1 CO for sensor and device monitoring 1 resistance sensor Up to 3 resistance sensors 1 thermocouple PT100 / 1000 KTY83 / 84 NTC1) 0 ... 999.9 s 0 ... 999.9 s 0 ... 99 K – 50 ... + 750 °C / – 58 ... + 1382 °F 3 CO Type J, K, T, E, N, S, R, B – 99 ... + 1800 °C / – 146,2 ... + 3272 °F NTC type B57227-K333-A1 (100 °C: 1,8 kΩ; 25 °C: 32,762 kΩ). 3RS1440- HB50 3RS1441- HB50 3RS1540- HB80 1 Screw terminals Spring-type terminals 2 The short-circuit and wire break detection as well as the measuring range are limited, depending on sensor type: Measuring ranges in °C for thermocouples Sensor Short type circuit Wire breakage ✓ 3RS1140 Meas. range in °C –99...999 3RS1142 Meas. range in °C –99...1200 Measuring ranges in °C for resistance sensors 3RS1540 Meas. range in °C –99...1350 J – K – ✓ –99...999 –99...1350 –99...1300 T – ✓ –99...400 –99...400 –99...1200 E – ✓ –99...999 –99...999 –99...999 N – ✓ –99...999 –99...999 –99...400 S – ✓ – 0...1750 0...1750 R – ✓ – 0...1750 0...1750 B – ✓ – 400...1800 400...1800 Sensor type 1) Short circuit Wire breakage 3RS1140, 3RS1141 Meas. range in °C 3RS1042, 3RS1440, 3RS1441 Meas. range in °C –50...750 PT100 ✓ ✓ –50...500 PT1000 ✓ ✓ –50...500 –50...500 KTY83-110 ✓ ✓ –50...175 –50...175 KTY84 ✓ ✓ –40...300 –40...300 NTC1) ✓ – 80...160 80...160 NTC type: B57227-K333-A1 (100 °C: 1.8 kΩ; 25 °C: 32.762 kΩ) 13 SIRIUS 3RS10 / 11 / 20 / 21 and 3RS14 / 15 Temperature Monitoring Relays PT100/1000; KTY83/84; NTC (resistance sensor)1) SIRIUS 3TX700 / 701 Coupling Relays 3TX7002 / 03 coupling relays – for small line distances or flat control cabinets Output couplers with relay output (compact enclosure) Output Rated control supply voltage Us 1 NO AC/DC 24 V 1 CO WxHxD in mm Hard gold plating Article No. 3TX700 -1AB00 3TX7002-1AB02 11.5 x 60 x 62 – 11.5 x 60 x 62 Yes AC/DC 24 V 17.5 x 60 x 62 – 230 V AC/DC 17.5 x 60 x 62 – 3TX700 -1BB00 3TX7002-1BF00 2 NO AC/DC 24 V 22.5 x 60 x 62 – 2 CO AC/DC 24 V 22.5 x 60 x 62 Yes 3TX700 -1CB00 3TX7002-1FB02 Input couplers with relay output (compact enclosure) 1 NO 1 CO 230 V AC/DC 230 V AC/DC 11.5 x 60 x 62 11.5 x 60 x 62 – – 3TX700 -2AF00 3TX7002-2AF05 AC/DC 110 V 11.5 x 60 x 62 – 3TX7002-2AE00 AC/DC 24 V 11.5 x 60 x 62 – 3TX7002-2AB00 230 V AC/DC 17.5 x 60 x 62 Yes 3TX7002-2BF02 Accessories Connection cable with 24 clamping points for 3TX70 3TX7004-8BA00 3TX7004-8AA00 Connection comb with 24 clamping points for 3TX7004 with 6.2 mm width and screw terminals 2 Screw terminals Spring-type terminals 3 3TX7004 / 05 coupling relays, not pluggable SIRIUS 3TX700 / 701 Coupling Relays Output couplers with relay output (6.2 mm width) Contacts Rated control supply voltage Us WxHxD in mm 1) 1 CO AC/DC 24 V 6,2 x 80 x 85 1 NO Hard gold plating – – Yes – 1) 2) Article No. 3TX700 -1LB00 12,5 x 80 x 85 – Yes 3TX700 -1LB02 3TX7004-1BB10 AC/DC 110 V 6,2 x 80 x 85 – – 3TX7005-1LN00 230 V AC/DC 6,2 x 80 x 85 – – 12,5 x 80 x 85 – – 3TX700 -1LF00 3TX7004-1BF052) AC/DC 24 V 6,2 x 80 x 85 – – 230 V AC/DC 6,2 x 80 x 85 – – 3TX700 -1MB00 3TX7004/05 – input couplers with relay output (6.2 mm width) 1 NO M-0-A switch 3TX700 -1MF00 230 V AC/DC 6,2 x 80 x 85 Yes – AC/DC 110 V 6,2 x 80 x 85 Yes – 3TX700 -2MF02 3TX7004-2ME02 AC/DC 24 V 6,2 x 80 x 85 Yes – 3TX700 -2MB02 4 Screw terminals Spring-type terminals 5 With 3TX7004 (screw terminals), the height amounts to 79 mm For long cable lengths up to 350 m 3TX7014 / 15 coupling relays with relay output, plug-in Coupling relays with plug-in relays (6,2 mm width) Contacts Rated control supply voltage Us WxHxD in mm Hard gold plating M-0-A switch Article No. 1 NO DC 24 V 6,2 x 90 x 92 – – 1 CO DC 24 V 6,2 x 90 x 92 – – 3TX701 -1AM00 AC/DC 24 V 6,2 x 90 x 92 – – 115 V AC/DC 6,2 x 90 x 92 – – 230 V AC/DC 6,2 x 90 x 92 – – Coupling relays with plug-in relays (6.2 mm width) 1 CO DC 24 V 6,2 x 90 x 92 Yes – AC/DC 24 V 6,2 x 90 x 92 Yes – 115 V AC/DC 6,2 x 90 x 92 Yes – 230 V AC/DC 6,2 x 90 x 92 Yes – Accessories 3TX701 -1BM00 3TX701 -1BB00 3TX701 -1BE00 3TX701 -1BF00 3TX701 -1BM02 3TX701 -1BB02 3TX701 -1BE02 3TX701 -1BF02 Wiring comb 16-pole for 3TX7014 and 3TX7015 plug-in base couplers 3TX7014-7AA00 Potential barrier for 3TX70 plug-in base couplers 3TX7014-7CE00 Configuration information When selecting the coupling links, the maximum permissible cable length has to be observed with rated control supply voltages of 110 V AC and 230 V AC. The special 3TX700-...05 type can be used for longer cables. 14 4 Screw terminals Spring-type terminals 5 SIRIUS 3TX700 and 3RS18 Coupling Relays 3TX7004 / 05 coupling relays with semiconductor output, not pluggable Output couplers with semiconductor output – in narrow, space-saving design, 1 NO contact (6.2 mm width) Rated control supply W x H x D voltage Us in mm1) DC 24 V AC 110–230 V Switching current max. Switching voltage Min. load current – Short-time load carrying capacity 1.5 A/20 ms M-0-A switch 6,2 x 80 x 85 0.5 A ≤ DC 48 V 6,2 x 80 x 85 1.5 A ≤ DC 11 – 30 V – Short-circuit-pr. – – 6,2 x 80 x 85 3A ≤ DC 30 V – Short-circuit-pr. – 12,5 x 80 x 85 5A ≤ DC 30 V 0.5 A Short-circuit-pr. – 12,5 x 80 x 85 5A ≤ DC 30 V 0.5 A Short-circuit-pr. Yes 12,5 x 80 x 85 2A AC 24 – 250 V 0.05 A 100 A/20 ms 6,2 x 80 x 85 3A ≤ DC 30 V Article Nr. 3TX700 -3AB04 3TX700 -3PB54 3TX700 -3PB74 3TX700 -3AC04 3TX700 -3AC14 – 3TX700 -3AC03 Short-circuit-pr. – 3TX700 -3PG74 0.2 A / 3 ms 3TX700 -4PG24 Input couplers with semiconductor output, 1 NO contact (6.2 mm width) AC/DC 110–230 V 1) 6,2 x 80 x 85 0.1 A ≤ DC 30 V – – With 3TX7004 (screw terminals), the height amounts to 79 mm 4 Screw terminals Spring-type terminals 5 3TX7002 coupling relays with semiconductor output, not pluggable Output couplers with semiconductor output – for low line heights, 1 NO contact, screw terminals (6.2 mm width) Rated control supply W x H x D voltage Us in mm1) Switching current max. Switching voltage DC 24 V 11.5 x 60 x 62 1.8 A DC 24 V 11.5 x 60 x 62 1.5 A Min. load current Short-time load carrying capacity Article No. AC 48 – 264 V 0.06 A 20 A/20 ms 3TX7002-3AB00 ≤ DC 60 V 4 A/200 ms 3TX7002-3AB01 – Input couplers with semiconductor output, 1 NO contact (6.2 mm width) AC/DC 24 V 11.5 x 60 x 62 0.1 A ≤ DC 30 V – 1 A/20 ms 3TX7002-4AB00 AC 110 – 240 V 11,5 x 60 x 62 0.1 A ≤ DC 30 V – 1 A/20 ms 3TX7002-4AG00 Accessories Connection cable with 24 clamping points for 3TX70 3TX7004-8BA00 Connection comb with 24 clamping points for 3TX7004 with 6.2 mm width and screw terminals 3TX7004-8AA00 3RS18 coupling relays Rated control supply voltage Us 50 / 60Hz Contact version Article No. Wide voltage AC/DC 24 – 240 V 2 CO 3RS18 00- BW00 3 CO 3RS18 00- HW00 3 CO hard gold-plated 3RS18 00- HW01 1 CO 3RS18 00- AQ00 2 CO 3RS18 00- BQ00 3 CO 3RS18 00- HQ00 3 CO hard gold-plated AC/DC 24 V and AC 220 – 240 V 3RS18 00- HQ01 1 CO 3RS18 00- AP00 2 CO 3RS18 00- BP00 3 CO 3RS18 00- HP00 3 CO hard gold-plated 3RS18 00- HP01 1 Screw terminals Spring-type terminals 2 SIRIUS LZS Coupling Relays LZS coupling relays with plug-in relays – for low line heights Output couplers Switching capacity of LZX plug-in relays AC-15, 230 V DC-13, 24 V RT 1 CO 6A 2A RT 2 CO 2.5 A 2A PT 2 CO 5A 5A PT 3 CO 5A 5A PT 4 CO DC coil: 4 A, AC coil: 2 A 4A MT 3 CO 5A 2A 15 SIRIUS 3TX700, 3RS18 / SIRIUS LZS Coupling Relays Combined voltage AC/DC 24 V and AC 110 – 120 V Logical isolation: The connections of the contact elements and the connections of the coil are arranged on different sides, e.g. for contact elements at the top, and for the coil at the bottom. This improves the transparency of wiring. The logical isolation is not necessarily a safe isolation. Safe isolation: Safe isolation is a separation that prevents overspill of voltage from one circuit to another with adequate safety. (DIN VDE 106 Part 101) Coupling relays with plug-in relays – LZS complete modules (base, plug-in relay, hold/eject clip, LED module and inscription plate) Versions Contacts Article No. 1) DC 24 V 3 CO LZS:PT3A5L24 Complete devices, 8-, 11- and 14-pole, PT range (28 mm width) Complete device with plug-in base (screw terminals, standard) for snap-on mounting on 35 mm DIN rail, consisting of: plug-in relay, standard plug-in base with screw terminals, LED module (24 V DC LED module with free-wheeling diode, AC without free-wheeling diode), hold/eject clip and inscription plate AC 24 V LZS:PT3A5R24 AC 115 V LZS:PT3A5S15 LZS:PT3A5T30 AC 230 V DC 24 V AC 24 V 4 CO LZS:PT5A5T30 AC 230 V Complete device with plug-in base (screw terminals, logical isolation) for snap-on mounting on 35 mm DIN rail, consisting of: plug-in relay, plug-in base with screw terminals and logical isolation, LED module (24 V DC LED module with free-wheeling diode, AC without free-wheeling diode), hold/eject clip and inscription plate Complete device with plug-in base (push-in spring-type terminals, logical isolation) for snap-on mounting on 35 mm DIN rail, consisting of: plug-in relay, plug-in base with spring-type terminals and logical isolation, LED module (24 V DC LED module with free-wheeling diode, AC without free-wheeling diode), hold/eject clip and inscription plate Complete device with plug-in base (screw terminals, standard) for snap-on mounting on 35 mm DIN rail, consisting of: plug-in relay, standard plug-in base with screw terminals, LED module (24 V DC LED module with free-wheeling diode, AC without free-wheeling diode), hold/eject clip and inscription plate Complete device with plug-in base (screw terminals, logical isolation) for snap-on mounting on 35 mm DIN rail, consisting of: plug-in relay with safe isolation, plug-in base with screw terminals and logical isolation, LED module (24 V DC module with free-wheeling diode, AC without free-wheeling diode), hold/eject clip and inscription plate Complete device with plug-in base (Push-in spring-type terminals, logical isolation) for snap-on mounting on 35 mm DIN rail, consisting of: plug-in relay, plug-in base with spring-type terminals and logical isolation, LED module (24 V DC LED module with free-wheeling diode, AC without free-wheeling diode), hold/eject clip and inscription plate LZS:PT5A5L24 LZS:PT5A5R24 LZS:PT5A5S15 AC 115 V Complete devices, 8-pole, 5 mm pinning, RT range (15.5 mm width) SIRIUS Coupling Relays with Plug-In Relays LZS / LZX Rated control supply voltage Us DC 24 V 4 CO LZS:PT5B5L24 AC 24 V LZS:PT5B5R24 AC 115 V LZS:PT5B5S15 AC 230 V LZS:PT5B5T30 DC 24 V 2 CO LZS:PT2D5L24 LZS:PT2D5T30 AC 230 V DC 24 V 4 CO LZS:PT5D5L24 AC 24 V LZS:PT5D5R24 AC 115 V LZS:PT5D5S15 AC 230 V LZS:PT5D5T30 DC 24 V 1 CO LZS:RT3A4L24 DC 24 V 2 CO LZS:RT4A4L24 AC 230 V 1 CO LZS:RT3A4T30 AC 230 V 2 CO LZS:RT4A4T30 AC 24 V 1 CO LZS:RT3A4R24 AC 24 V 2 CO LZS:RT4A4R24 AC 115 V 1 CO LZS:RT3A4S15 AC 115 V 2 CO DC 24 V 1 CO LZS:RT3B4L24 DC 24 V 2 CO LZS:RT4B4L24 AC 230 V 1 CO LZS:RT3B4T30 AC 230 V 2 CO LZS:RT4B4T30 AC 24 V 1 CO LZS:RT3B4R24 AC 24 V 2 CO LZS:RT4B4R24 AC 115 V 1 CO LZS:RT3B4S15 AC 115 V 2 CO DC 24 V 1 CO LZS:RT3D4L24 DC 24 V 2 CO LZS:RT4D4L24 AC 230 V 1 CO LZS:RT3D4T30 AC 230 V 2 CO LZS:RT4D4T30 AC 24 V 1 CO LZS:RT3D4R24 AC 24 V 2 CO LZS:RT4D4R24 AC 115 V 1 CO LZS:RT3D4S15 AC 115 V 2 CO LZS:RT4D4S15 LZS:RT4A4S15 LZS:RT4B4S15 Coupling relays with plug-in relays – individual modules for self-assembly (LZX) RT range Plug-in relays 16 Logical isolation Hard gold plating Article No. – Freewheeling diode – – – LZX:RT424012 – – – – LZX:RT314024 2 CO – – – – LZX:RT424024 AC 24 V 1 CO – – – – LZX:RT424524 AC 24 V 2 CO – – – – LZX:RT424524 AC 115 V 1 CO – – – – LZX:RT314615 AC 115 V 2 CO – – – – LZX:RT424615 AC 230 V 1 CO – – – – LZX:RT314730 AC 230 V 2 CO – – – – LZX:RT424730 DC 24 V 1 CO – – – Yes LZX:RT315024 AC 230 V 1 CO – – – Yes LZX:RT315730 Rated control supply Contacts voltage Us LED DC 12 V 2 CO DC 24 V 1 CO DC 24 V RT range Accessories, suitable for 1 and 2 CO Plug-in base with screw terminals for DIN rail mounting No logical isolation (standard) LZS:RT78725 Logical isolation LZS:RT78726 Plug-in base with push-in spring-type terminals for DIN rail mounting Hold/eject clip Logical isolation LZS:RT7872P – LZS:RT17016 Wiring bracket for push-in spring-type terminal base 2-pole LZS:RT170P1 Inscription plate Wiring comb for screw terminal base LZS:RT17040 LZS:RT170R8 8-pole PT range Plug-in relays Hard gold plating Test bracket Article No. – Free-wheeling diode – – Yes LZX:PT270024 – – – Yes LZX:PT570024 Rated control supply Contacts voltage Us LED DC 24 V 2 CO DC 24 V 4 CO DC 24 V DC 24 V AC 24 V AC 24 V AC 24 V AC 115 V AC 115 V AC 115 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V 3 CO – 4 CO – 4 CO – 2 CO – 3 CO – 4 CO – 2 CO – 3 CO – 4 CO – 2 CO – 3 CO – 4 CO – 4 CO – 4 CO – – – – Yes – – – Yes – Yes – – Yes – – Yes – – Yes – – Yes – – Yes – – Yes – – Yes – – Yes – – Yes Yes – Yes – Accessories Plug-in base with screw terminals for DIN rail mounting – 2 CO No logical isolation LZX:PT370024 LZX:PT520024 LZX:PT580024 LZX:PT270524 LZX:PT370524 LZX:PT570524 LZX:PT270615 LZX:PT370615 LZX:PT570615 LZX:PT270730 LZX:PT370730 LZX:PT570730 LZX:PT580730 LZX:PT520730 LZS:PT78720 LZS:PT78730 3 CO LZS:PT78740 4 CO 2 CO Logical isolation LZS:PT78722 LZS:PT78742 4 CO Logical isolation LZS:PT7872P Plug-in base with push-in spring-type terminals for DIN rail mounting 2 CO 4 CO LZS:PT7874P Hold/eject clip 2/3/4 CO Logical isolation LZS:PT17021 Hold/eject clip for screw terminal base 2/3/4 CO No logical isolation LZS:PT17024 LZS:PT17040 Inscription plate Wiring bracket for push-in spring-type terminal base 2-pole LZS:PT170P1 Wiring comb for screw terminal base 6-pole LZS:PT170R6 Accessories for RT and PT range DC 24 V Free-wheeling diode LZS:PTML0024 AC/DC 24 V – LZS:PTML0524 AC 110 – 230 V – LZS:PTML0730 DC 24 V Free-wheeling diode LZS:PTMG0024 AC/DC 24 V – LZS:PTMG0524 AC 110 – 230 V – LZS:PTMG0730 Free-wheeling diode DC 6 – 230 V Free-wheeling diode LZS:PTMT00A0 RC link AC 24 – 48 V – LZS:PTMU0524 AC 110 – 230 V – LZS:PTMU0730 LED module red Control supply voltage LED module green MT range Plug-in relays Rated control supply voltage Us DC 24 V Contacts 3 CO LED – Free-wheeling diode – Article No. LZX:MT321024 AC 24 V 3 CO – – LZX:MT326024 DC 24 V AC 24 V AC 115 V AC 115 V AC 230 V AC 230 V Accessories 3 CO 3 CO 3 CO 3 CO 3 CO 3 CO Yes Yes – Yes – Yes Plug-in base with screw terminals for DIN rail mounting, 11-pole Hold clip – – – – – – LZX:MT323024 LZX:MT328024 LZX:MT326115 LZX:MT328115 LZX:MT326230 LZX:MT328230 LZS:MT78750 LZS:MT28800 17 SIRIUS Coupling Relays with Plug-In Relays LZS / LZX DC 24 V SIRIUS 3RS17 Interface Converters Single interface converters, active, 2-way isolation Input Output Width Manual-automatic Rated control supply voltage Us Galvanic isolation 0 – 10 V 0 – 10 V 6.2 mm – AC/DC 24 V 2-way 0 – 10 V 0 – 20 mA 6.2 mm – AC/DC 24 V 2-way 0 – 10 V 4 – 20 mA 6.2 mm – AC/DC 24 V 2-way 0 – 20 mA 0 – 10 V 6.2 mm – AC/DC 24 V 2-way 0 – 20 mA 0 – 20 mA 6.2 mm – AC/DC 24 V 2-way 0 – 20 mA 4 – 20 mA 6.2 mm – AC/DC 24 V 2-way 4 – 20 mA 0 – 10 V 6.2 mm – AC/DC 24 V 2-way 4 – 20 mA 0 – 20 mA 6.2 mm – AC/DC 24 V 2-way 4 – 20 mA 4 – 20 mA 6.2 mm – AC/DC 24 V 2-way 0 – 20 mA 0 – 20 mA 6.2 mm – Passive converter 2-way 0 – 20 mA 0 – 20 mA 12.5 mm – Passive converter 2-way 2 x 0 – 20 mA 2 x 0 – 20 mA 12.5 mm – Passive converter 2-way Article No. 3RS1700- AD00 3RS1700- CD00 3RS1700- DD00 3RS1702- AD00 3RS1702- CD00 3RS1702- DD00 3RS1703- AD00 3RS1703- CD00 3RS1703- DD00 3RS1720- ET00 3RS1721- ET00 3RS1722- ET00 Single interface converters, active, 3-way isolation 0 – 10 V 0 – 10 V 6.2 mm – AC/DC 24 V 3-way 0 – 10 V 0 – 20 mA 6.2 mm – AC/DC 24 V 3-way 0 – 10 V 4 – 20 mA 6.2 mm – AC/DC 24 V 3-way 0 – 20 mA 0 – 10 V 6.2 mm – AC/DC 24 V 3-way 0 – 20 mA 0 – 20 mA 6.2 mm – AC/DC 24 V 3-way 0 – 20 mA 4 – 20 mA 6.2 mm – AC/DC 24 V 3-way 4 – 20 mA 0 – 10 V 6.2 mm – AC/DC 24 V 3-way 4 – 20 mA 0 – 20 mA 6.2 mm – AC/DC 24 V 3-way 4 – 20 mA 4 – 20 mA 6.2 mm – AC/DC 24 V 3-way 3RS1700- AE00 3RS1700- CE00 3RS1700- DE00 3RS1702- AE00 3RS1702- CE00 3RS1702- DE00 3RS1703- AE00 3RS1703- CE00 3RS1703- DE00 Multi-range converters, switchable, active 0 – 10 V 0/4 – 20 mA adjustable 0 – 10 V 0/4 – 20 mA adjustable 0 – 10 V 0/4 – 20 mA adjustable 0 – 10 V 0/4 – 20 mA adjustable 0 – 10 V 0/4 – 20 mA adjustable 0 – 50 Hz 0 – 100 Hz 0 – 1 kHz 0 – 10 kHz adjustable 6.2 mm – AC/DC 24 V 2-way 6.2 mm – AC/DC 24 V 3-way 17.5 mm – AC/DC 24 – 240 V 3-way 17.5 mm Yes AC/DC 24 V 2-way 17.5 mm Yes AC/DC 24 – 240 V 3-way 3RS1705- FD00 3RS1705- FE00 3RS1705- FW00 3RS1725- FD00 3RS1725- FW00 6.2 mm – AC/DC 24 V 2-way 17.5 mm – AC/DC 24 – 240 V 3-way 3RS1705- KW00 AC/DC 24 V 2-way AC/DC 24 V 3-way 3RS1706- FD00 AC/DC 24 – 240 V 3-way 3RS1705- KD00 Universal converters, active, with 16 input and output ranges 0 – 60 mV 0 – 100 mV 0 – 300 mV 0 – 500 mV 0 – 1 V 0 – 2 V 0 – 5 V 0 – 10 V 0 – 20 V 2 – 10 V SIRIUS 3RS17 Interface Converters 0 – 5 mA 0 – 10 V 0/4 – 20 mA adjustable 17.5 mm – 3RS1706- FE00 3RS1706- FW00 0 – 10 mA 0 – 20 mA 4 – 20 mA ± 5 mA ± 20 mA 1 Screw terminals Spring-type termianls 2 18 SIRIUS 3TG10 Power Relays AC-1 operating current Ie with 400 V AC-1 power of three-phase loads with 50 Hz 400 V AC-2 and AC-3 operating current with 400 V Contacts AC-2 and AC-3 three-phase loads with 50 Hz 400 V (A) (kW) (A) (kw) 20 13 8.4 4 20 16 16 13 10 10 8.4 8.4 8.4 4 4 4 3 NO + 1 NC 4 NO 3 NO + 1 NC 4 NO Connection system Rated control supply Article No. voltage Us Screw terminals AC 24 V 3TG1001-0AC2 AC 110 V 3TG1001-0AG2 AC 230 V 3TG1001-0AL2 DC 24 V 3TG1001-0BB4 AC 24 V 3TG1010-0AC2 AC 110 V 3TG1010-0AG2 AC 230 V 3TG1010-0AL2 DC 24 V 3TG1010-0BB4 AC 24 V 3TG1001-1AC2 AC 110 V 3TG1001-1AG2 AC 230 V 3TG1001-1AL2 DC 24 V 3TG1001-1BB4 AC 24 V 3TG1010-1AC2 AC 110 V 3TG1010-1AG2 AC 230 V 3TG1010-1AL2 DC 24 V 3TG1010-1BB4 Screw terminals Flat connectors Flat connectors 19 SIRIUS 3TG10 Power Relays 3TG10 power relays Scan the QR code for further information Further information: siemens.com/relays Siemens AG Industry Sector Control Components and Systems Engineering P.O. Box 2355 90713 FÜRTH GERMANY Subject to change without prior notice 07/14 Article No. E20001-A1800-P302-V2-7600 Dispo 27601 21/52900 WS 08142.0 Printed in Germany © Siemens AG 2014 The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks and product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.