TSFE160

TSFE
Gas filled thermometer with capillary and contacts
Main Features
„„
For corrosive gasses and
liquids
„„
Class 1 according to
EN 13190
„„
Capillary 0.5 to 30 m
„„
Mechanical or inductive
contacts
„„
Wetted parts and case material
stainless steel
„„
Option : case material 1.4404
(316L) for aggressive atmosphere
Applications
„„Food & Beverage
„„Oil & Gas / Chemical
„„Laboratory & Medical
„„Energy
Technical Data
ATEX
100, 160 mm
Temperature ranges -200 ... 800 °C
Accuracy
Class 1 (according to EN 13190)
Protection rating
IP 65 (EN 60529)
Immersion tube
Stainless steel 1.4541 (AISI 321)
Capillary
Stainless steel 1.4541 (AISI 321)
max. length 30 m
Bezel ring
Stainless steel 1.4301 (AISI 304)
Window
Laminated safety glass
Movement
Brass
Window gasket
Elastomer
Dial
Aluminium, white
Pointer
Aluminium, black
Accessories
Sliding connections and thermowells, see datasheets: B51.01 (AGF/AGW) and T6.215 (Ø 8)
Temperature limit
130 % F.S.
Only for inductive contacts (type 8xxx)
Type examination certificate
DEKRA 14 ATEX 0034
EN 60079-0 : 2009
EN 60079-11 : 2007
EN 61241-11 : 2006
Marking
0344
II 2 G
Ex ia IIC T4 Gb
II 2 D
Ex ia IIIC T135 °C ... T85 °C Db
Electrical data
Umax = 20 Vdc
Imax = 60 mA
Pmax = 130 mW
Sensor type: SI2-K08-Y1 (Turck)
This certification is valid for connection to a certified intrinsically safe
circuit with maximum values as listed above and in the instructions
and certificate of the sensor.
Options
Code 9003_xxxx
Stainless steel housing 1.4404 (316L)
Code 0110
Customer specific immersion length (1)
Movement stainless steel
Code 0651
Red mark
Code 9700
Process connections (see table on page 4/5)
Code 73xx
Green mark
Code 9701
Oil filling (paraffin oil, Ondina)
Code 0777
Stainless steel tag plate and wire
Code 9941
Screws secured with loctite
Code 0799
xxxx = L in mm.
2014-12-09
(1)
Design and specifications subject to change without notice
Nominal size
www.baumer.com
Data sheet B22 T2.310 TSFE
Page 1 / 7
TSFE
Gas filled thermometer with capillary and contacts
Dimensions in mm
Type C (Code 21)
20
K2
A
°
120
Ø15
PG 9
60
K1
Dimensions
Diameter
Dimensions
Diameter
100
160
A
101
161
83
100
160
B
80
A
101
161
C
13
13
B
104
108
D
132
196
K
92
122
H
5.5
116
178
K1
92
122
K2
15
0
Type B (Code 22)
Dimensions
B
A
K2
C2
°
120
PG 9
Diameter
100
160
A
101
161
B
80
83
C1
26
0
C2
10
0
D
132
196
H
K1
6
P
5.5
6
P
116
178
K1
123
126
K2
15
0
Type A (Code 31)
Diameter
161
B
110
114
C
19
19
D
132
196
H
5.5
A
101
°
160
A
120
100
D
Dimensions
6
116
178
K
92
122
2014-12-09
P
Design and specifications subject to change without notice
Ø12
www.baumer.com
Data sheet B22 T2.310 TSFE
Page 2 / 7
TSFE
Gas filled thermometer with capillary and contacts
Dimensions in mm
Dimensions
Diameter
100
160
101
161
A
°
120
51
B
110
114
D
132
196
5.5
H
PG 9
6
P
116
178
K
92
122
Type G (Code 53)
160
101
161
B
84
88
C
25
0
D
112
180
E
109
113
P
75
139
K1
128
131
K2
15
54
C
100
A
A
Diameter
K2
Dimensions
Type D (Code 61)
100
160
A
101
161
B
104
108
K
92
122
Design and specifications subject to change without notice
Diameter
2014-12-09
56
Ø7 (3x)
A
Dimensions
www.baumer.com
Data sheet B22 T2.310 TSFE
Page 3 / 7
TSFE
Gas filled thermometer with capillary and contacts
Types of capillary
Type
Code
Models
Ø d in mm
Tmin in °C
Tmax in °C
Stainless steel 1.4541 (321) without
protection
6
2
- 250
+ 800
Stainless steel 1.4541 (321) with PVC
coating
7
4
- 60
+ 120
Stainless steel 1.4541 (321) with
stainless steel protection 1.4301 (304)
B
6
- 260
+ 800
Stainless steel 1.4541 (321) with
stainless steel protection 1.4301 (304)
and PVC coating
C
7.5
- 60
+ 120
Process connections
Coupling nut (long model)
Rotating nipple (standard)
Rotating nipple (long model)
www.baumer.com
Connection
HEX-1
HEX-2
T
731A
G¼
22
-
7
Ø 6 to 8
731B
G⅜
27
-
9
Ø 6 to 11
731C
G½
27
-
9
Ø 6 to 15
731D
G¾
32
-
9
Ø 6 to 20
731E
G1
41
-
13
Ø 6 to 20
731P
M18 x 1.5
27
-
8
Ø 6 to 12
731Q
M20 x 1.5
27
-
9
Ø 6 to 14
731R
M24 x 1.5
32
-
9
Ø 6 to 18
732C
G½
27
-
14
Ø 6 to 15
732D
G¾
32
-
16
Ø 6 to 20
732E
G1
41
-
18
Ø 6 to 20
733A
G¼
17
-
12
Ø 6 to 8
733B
G⅜
22
-
12
Ø 6 to 11
733C
G½
22
-
14
Ø 6 to 15
733D
G¾
30
-
16
Ø 6 to 20
733E
G1
36
-
18
Ø 6 to 20
733P
M18 x 1.5
22
-
12
Ø 6 to 12
733Q
M20 x 1.5
22
-
14
Ø 6 to 14
733R
M24 x 1.5
27
-
14
Ø 6 to 18
734C
G½
22
-
20
Ø 6 to 15
734D
G¾
30
-
20
Ø 6 to 20
734E
G1
36
-
25
Ø 6 to 20
Data sheet B22 T2.310 TSFE
Page 4 / 7
Design and specifications subject to change without notice
Coupling nut (standard)
Immersion tube
(mm)
Code
2014-12-09
Models
TSFE
Gas filled thermometer with capillary and contacts
Process connections
Connection
Coupling nut + double nipple
Sliding connection on the extension tube
Sliding connection on the capillary
Sliding connection on the stem
HEX-1
HEX-2
T
Immersion tube
(mm)
735A
G¼
27
22
12
Ø 6 to 8
735B
G⅜
27
22
12
Ø 6 to 11
735C
G½
27
22
14
Ø 6 to 15
735D
G¾
27
27
16
Ø 6 to 20
735E
G1
27
36
18
Ø 6 to 20
735H
¼ NPT
27
22
14
Ø 6 to 8
735J
½ NPT
27
22
20
Ø 6 to 15
735K
¾ NPT
27
27
20
Ø 6 to 20
735L
1" NPT
27
36
25
Ø 6 to 20
735P
M18 x 1.5
27
22
12
Ø 6 to 12
735Q
M20 x 1.5
27
22
14
Ø 6 to 14
735R
M24 x 1.5
27
27
14
Ø 6 to 18
736A
G¼
22
27
12
Ø 6 to 11
736B
G⅜
22
27
12
Ø 6 to 14
736C
G½
22
27
14
Ø 6 to 18
736D
G¾
22
32
16
Ø 6 to 23
736E
G1
22
36
18
Ø 6 to 30
736H
¼ NPT
22
27
14
Ø 6 to 13
736J
½ NPT
22
27
20
Ø 6 to 20
736K
¾ NPT
22
27
20
Ø 6 to 25
736L
1" NPT
22
36
25
Ø 6 to 32
736P
M18 x 1.5
22
27
12
Ø 6 to 16
736Q
M20 x 1.5
22
27
14
Ø 6 to 18
736R
M24 x 1.5
22
27
14
Ø 6 to 22
737A
G¼
22
27
12
Ø 6 to 11
737B
G⅜
22
27
12
Ø 6 to 14
737C
G½
22
27
14
Ø 6 to 18
737D
G¾
22
32
16
Ø 6 to 23
737E
G1
22
36
18
Ø 6 to 30
737H
¼ NPT
22
27
14
Ø 6 to 13
737J
½ NPT
22
27
20
Ø 6 to 20
737K
¾ NPT
22
27
20
Ø 6 to 25
737L
1" NPT
22
36
25
Ø 6 to 32
737P
M18 x 1.5
22
27
12
Ø 6 to 16
737Q
M20 x 1.5
22
27
14
Ø 6 to 18
737R
M24 x 1.5
22
27
14
Ø 6 to 22
738A
G¼
22
27
12
Ø 6 to 8
738B
G⅜
22
27
12
Ø 6 to 11
738C
G½
22
27
14
Ø 6 to 15
738D
G¾
22
32
16
Ø 6 to 20
738E
G1
22
36
18
Ø 6 to 20
738H
¼ NPT
22
27
14
Ø 6 to 8
738J
½ NPT
22
27
20
Ø 6 to 15
738K
¾ NPT
22
27
20
Ø 6 to 20
738L
1" NPT
22
36
25
Ø 6 to 20
738P
M18 x 1.5
22
27
12
Ø 6 to 12
738Q
M20 x 1.5
22
27
14
Ø 6 to 14
738R
M24 x 1.5
22
27
14
Ø 6 to 18
Note: minimum immersion length: see table on page 6
www.baumer.com
Data sheet B22 T2.310 TSFE
Page 5 / 7
Design and specifications subject to change without notice
Code
2014-12-09
Models
TSFE
Gas filled thermometer with capillary and contacts
Temperature ranges
Code
Range
Code
Range
°C
Code
Range
°C
Code
°F
Range (double scale)
°C
/
°F
70
/
-40 ...
-70 ...
50
/ -100 ...
100
-30 ...
170
/
0 ...
350
11V
0 ...
60
/
30 ...
140
250
20V
0 ...
120
/
30 ...
250
300
13V
0 ...
160
/
30 ...
320
0 ...
250
/
30 ...
500
0 ...
400
/
30 ...
750
600
/
100 ...
1100
69T
-200 ...
50
12T
0 ...
100
68U
-100 ...
120
51V
-30 ...
77T
-120 ...
40
20T
0 ...
120
09U
-50 ...
120
68V
76T
-100 ...
50
13T
0 ...
160
08U
-40 ...
160
55V
74T
-80 ...
40
22T
0 ...
200
02U
0 ...
200
68T
-70 ...
50
14T
0 ...
250
03U
0 ...
50T
-60 ...
40
23T
0 ...
300
04U
0 ...
65T
-40 ...
40
15T
0 ...
400
05U
0 ...
400
14V
55T
-30 ...
170
25T
0 ...
500
06U
0 ...
500
15V
51T
-30 ...
70
16T
0 ...
600
20U
30 ...
250
16V
0 ...
61T
-30 ...
30
82T
0 ...
800
13U
30 ...
320
84T
-20 ...
100
30T
100 ...
500
22U
30 ...
400
54T
-20 ...
60
23U
30 ...
580
52T
-20 ...
40
15U
30 ...
750
11T
0 ...
60
28U
100 ...
800
27T
0 ...
80
29U
200 ...
1000
160
Minimum immersion length Ls (mm)
Diameter of the Immersion tube (mm)
Ø8
Ø9
Ø 10
Ø 11
Ø 12
Ø 14
Ø 16
≤2
≤5
≤ 10
≤ 20
≤ 30
70
35
30
25
20
18
15
13
160
160
160
160
160
120
60
45
35
30
25
20
17
80
80
80
80
100
190
90
60
55
45
35
30
25
60
-
-
-
-
-
135
100
80
65
55
40
30
-
60
-
-
80
-
170
130
100
80
65
50
40
-
-
60
-
-
-
-
190
150
120
95
70
55
-
-
-
60
-
←
Ø6
←
How to use this table:
1. Select in the right table the first column, which
covers your capillary length.
2. Move down in this column to the first value,
which is not higher than your temperature span.
3. Move horizontal to the left table into the column
with your selected immersion tube diameter.
4. Read the minimum length of the sensitive part of
the immersion tube for your selection.
Capillary length (m)
Length of sensitive part Ls (mm)
If this is too long, choose a larger diameter, a larger
range or a shorter capillary.
Example:
4 m capillary, -20 … 40 °C (span = 60 °C),
Immersion tube Ø 10 mm:
Minimum length of the sensitive part: Ls ≥ 80 mm
Min. temperature span (°C)
Standard version with plain immersion tube (without process connection)
TSFE
100
–
2
61
.
1
B
2
.
20T
.
30
.
5001
/
738C
Gas filled thermometer with capillary and contacts
Nominal size 100 mm
Case material stainless steel 1.4301 (AISI 304)
Support console for wall mounting, capillary outlet bottom
Immersion tube diameter 8 mm
Capillary stainless steel 1.4541 with stainless steel
protection 1.4301 Ø 6 mm (up to 800 °C)
Immersion tube, installed length L = 100 mm
Temperature range: 0 ... 120 °C
Length of capillary: 3 m
2014-12-09
Mechanical contact makes (NO) with clockwise pointer motion
Option: Adjustable connection sliding on stem G½
www.baumer.com
Design and specifications subject to change without notice
Ordering example with options
Data sheet B22 T2.310 TSFE
Page 6 / 7
TSFE
Gas filled thermometer with capillary and contacts
Ordering details TSFE
– 2 xx
TSFE
/
–
2
11
21
22
31
32
53
61
.
4
1
A
B
2
C
7
D
6
7
B
C
2
4
6
7
8
9
0
.
xxT
xxU
xxV
.
10
30
60
90
A2
A5
B0
C0
Mechanical contacts (snap-action)
Contact makes (NO) (1)
Contact breaks (NC) (1)
Changeover contact (SPDT)
1st contact makes / 2nd contact makes (NO/NO) (1)
1st contact makes / 2nd contact breaks (NO/NC) (1)
1st contact breaks / 2nd contact makes (NC/NO) (1)
1st contact breaks / 2nd contact breaks (NC/NC) (1)
Double changeover contact (SPDT/SPDT)
1st contact makes / 2nd contact makes (NO/NO, separate circuits) (1)
1st contact makes / 2nd contact breaks (NO/NC, separate circuits) (1)
1st contact breaks / 2nd contact makes (NC/NO, separate circuits) (1)
1st contact breaks / 2nd contact breaks (NC/NC, separate circuits) (1)
.
5001
5002
5003
5 0 11
5012
5021
5022
5033
5055
5056
5065
5066
Inductive contacts (Namur, DIN EN 60947-5-6)
Contact makes (NO) (1)
Contact breaks (NC) (1)
1st contact makes / 2nd contact makes (NO/NO) (1)
1st contact makes / 2nd contact breaks (NO/NC) (1)
1st contact breaks / 2nd contact makes (NC/NO) (1)
1st contact breaks / 2nd contact breaks (NC/NC) (1)
Options to be added behind the / (see example page 6)
(1)
. xxxx
Design and specifications subject to change without notice
1 0 0
1 6 0
Immersion tube diameter
6 mm
8 mm
9 mm
10 mm
11 mm
12 mm
14 mm
16 mm
Type of capillary
Stainless steel 1.4541 without protection, Ø 2.0 mm (up to 800 °C)
Stainless steel 1.4541 with PVC, Ø 4.0 mm (up to 120 °C)
Stainless steel 1.4541 with stainless steel protection 1.4301, Ø 6.0 mm (up to 800 °C)
Stainless steel 1.4541 with stainless steel protection 1.4301 + PVC, Ø 7.5 mm (up to 120 °C)
Immersion tube / installed length L
100 mm
160 mm
250 mm
400 mm
600 mm
1000 mm
Customer specific length (use option 9003_xxxx, xxxx = L in mm)
Length of capillary
1m
3m
6m
9m
12 m
15 m
20 m
30 m
. xx
TSFE
Case
Stainless steel 1.4301 (AISI 304)
Type of mounting
Direct mounting, capillary outlet bottom
Front flange for panel mounting, capillary outlet bottom
Front flange for panel mounting, capillary outlet center back
Rear flange for wall mounting, capillary outlet bottom
Rear flange for wall mounting, capillary outlet center back
U-clamp for panel mounting, capillary outlet lower back
Support console for wall mounting, capillary outlet bottom
Unit of measurement / Temperature ranges
°C
°F
°C / °F (double scale)
. xxx
.
8001
8002
8 0 11
8012
8021
8022
/
with clockwise pointer motion.
www.baumer.com
Data sheet B22 T2.310 TSFE
Page 7 / 7
2014-12-09
Model
Gas filled thermometer with capillary and contacts
Nominal size
100 mm
160 mm