TSSE Gas filled thermometer with contacts Main Features For corrosive gasses and liquids Class 1 according to EN 13190 Wetted parts and case material stainless steel Mechanical or inductive contacts Option: case material 1.4404 (316L) for aggressive atmosphere Applications Food & Beverage Oil & Gas / Chemical Laboratory & Medical Energy Technical Data ATEX 100, 160 mm Temperature ranges -200 ... 800 °C Accuracy Class 1 (according to EN 13190) Protection rating IP 65 (EN 60529) Immersion tube Stainless steel 1.4541 (AISI 321) Case Stainless steel 1.4301 (AISI 304) Bezel ring Stainless steel 1.4301 (AISI 304) Window Laminated safety glass Movement Brass Window gasket Elastomer Dial Aluminium, white Pointer Aluminium, black Accessories Sliding connections and thermowells, see datasheets: B51.01 (AGF/AGW) and T6.215 (Ø 8) Temperature limit 130 % F.S. Only for inductive contacts (type 8xxx) Type examination certificate DEKRA 14 ATEX 0034 EN 60079-0 : 2009 EN 60079-11 : 2007 EN 61241-11 : 2006 Marking 0344 II 2 G Ex ia IIC T4 Gb II 2 D Ex ia IIIC T135 °C ... T85 °C Db Electrical data Umax = 20 Vdc Imax = 60 mA Pmax = 130 mW Sensor type: SI2-K08-Y1 (Turck) This certification is valid for connection to a certified intrinsically safe circuit with maximum values as listed above and in the instructions and certificate of the sensor. Options Code 9003_xxxx Stainless steel housing 1.4404 (316L) Code 0110 Customer specific immersion length (1) Movement stainless steel Code 0651 Red mark Code 9700 Process connections (see table on page 3) Code 73xx Green mark Code 9701 Oil filling (paraffin oil, Ondina) Code 0777 Stainless steel tag plate and wire Code 9941 Screws secured with loctite Code 0799 xxxx = L in mm. 2015-10-13 (1) Design and specifications subject to change without notice Nominal size www.baumer.com Data sheet B22 T2.305 TSSE Page 1 / 5 TSSE Gas filled thermometer with contacts Dimensions in mm Type F (Code 12) B B A 46 A Ø 15 Ø 15 46 13 20 20 K PG 9 PG 9 K Ø 15 Diameter Dimensions 100 160 A 101 161 B 104 K 92 Diameter Dimensions 100 160 A 101 161 108 B 104 108 122 K 92 122 Type E (Code 32) P A B 12 Ø 15 D 0° 46 20 PG 9 F Diameter Dimensions H K Type A (Code 41) 100 160 A 101 161 B 110 114 D 132 196 F 5 5 H 5.5 6 P 116 178 K 92 122 Type F (Code 42) B A B 110 55 Ø 15 46 A 46 Ø 15 20 56 90 ° 20 PG 9 K 20 112 Ø 15 Design and specifications subject to change without notice 20 90° K PG 9 360° 13 Ø 15 Diameter Dimensions Diameter 100 160 100 160 A 101 161 A 101 161 B 104 108 B 104 108 K 92 122 K 92 122 www.baumer.com Data sheet B22 T2.305 TSSE 2015-10-13 Dimensions Page 2 / 5 TSSE Gas filled thermometer with contacts Process connections Models Coupling nut (standard) L HEX _ 1 d 15 Ø 3 T HEX-1 HEX-2 T 731A G¼ 22 - 7 Ø 6 to 8 731B G⅜ 27 - 9 Ø 6 to 11 731C G½ 27 - 9 Ø 6 to 15 731D G¾ 32 - 9 Ø 6 to 20 731E G1 41 - 13 Ø 6 to 20 731P M18 x 1.5 27 - 8 Ø 6 to 12 731Q M20 x 1.5 27 - 9 Ø 6 to 14 731R M24 x 1.5 32 - 9 Ø 6 to 18 732C G½ 27 - 14 Ø 6 to 15 732D G¾ 32 - 16 Ø 6 to 20 732E G1 41 - 18 Ø 6 to 20 733A G¼ 17 - 12 Ø 6 to 8 LS Coupling nut (long model) Rotating nipple (standard) Rotating nipple (long model) Sliding connection Connection 733B G⅜ 22 - 12 Ø 6 to 11 733C G½ 22 - 14 Ø 6 to 15 733D G¾ 30 - 16 Ø 6 to 20 733E G1 36 - 18 Ø 6 to 20 733P M18 x 1.5 22 - 12 Ø 6 to 12 733Q M20 x 1.5 22 - 14 Ø 6 to 14 733R M24 x 1.5 27 - 14 Ø 6 to 18 734C G½ 22 - 20 Ø 6 to 15 734D G¾ 30 - 20 Ø 6 to 20 734E G1 36 - 25 Ø 6 to 20 738A G¼ 22 27 12 Ø 6 to 8 738B G⅜ 22 27 12 Ø 6 to 11 738C G½ 22 27 14 Ø 6 to 15 738D G¾ 22 32 16 Ø 6 to 20 738E G1 22 36 18 Ø 6 to 20 738H ¼ NPT 22 27 14 Ø 6 to 8 738J ½ NPT 22 27 20 Ø 6 to 15 738K ¾ NPT 22 27 20 Ø 6 to 20 738L 1" NPT 22 36 25 Ø 6 to 20 738P M18 x 1.5 22 27 12 Ø 6 to 12 738Q M20 x 1.5 22 27 14 Ø 6 to 14 738R M24 x 1.5 22 27 14 Ø 6 to 18 2015-10-13 Note: minimum immersion length: see table on page 4 Design and specifications subject to change without notice 45 20 Immersion tube (mm) Code www.baumer.com Data sheet B22 T2.305 TSSE Page 3 / 5 TSSE Gas filled thermometer with contacts Temperature ranges Code Range Code Range °C Code Range °C Code °F Range (double scale) °C / °F 70 / -40 ... -70 ... 50 / -100 ... 100 -30 ... 170 / 0 ... 350 11V 0 ... 60 / 30 ... 140 250 20V 0 ... 120 / 30 ... 250 300 13V 0 ... 160 / 30 ... 320 0 ... 250 / 30 ... 500 0 ... 400 / 30 ... 750 600 / 100 ... 1100 69T -200 ... 50 12T 0 ... 100 68U -100 ... 120 51V -30 ... 77T -120 ... 40 20T 0 ... 120 09U -50 ... 120 68V 76T -100 ... 50 13T 0 ... 160 08U -40 ... 160 55V 74T -80 ... 40 22T 0 ... 200 02U 0 ... 200 68T -70 ... 50 14T 0 ... 250 03U 0 ... 50T -60 ... 40 23T 0 ... 300 04U 0 ... 65T -40 ... 40 15T 0 ... 400 05U 0 ... 400 14V 55T -30 ... 170 25T 0 ... 500 06U 0 ... 500 15V 51T -30 ... 70 16T 0 ... 600 20U 30 ... 250 16V 0 ... 61T -30 ... 30 82T 0 ... 800 13U 30 ... 320 84T -20 ... 100 30T 100 ... 500 22U 30 ... 400 54T -20 ... 60 23U 30 ... 580 52T -20 ... 40 15U 30 ... 750 11T 0 ... 60 28U 100 ... 800 27T 0 ... 80 29U 200 ... 1000 160 Minimum immersion length Ls (mm) Ø6 Ø8 Ø9 Ø 10 Ø 11 Ø 12 Ø 14 Ø 16 Temperature Span ≥ 120 °C 70 35 30 25 20 18 15 13 Temperature Span ≥ 60 °C 120 60 45 35 30 25 20 17 Immersion tube (mm) Standard version with plain immersion tube (without process connection) L 45 Ø 15 20 Lt Ls Gas filled thermometer with rigid stem and contacts TSSE 100 – 2 11 . 1 6 0 . 12T . 5001 / 738C _ 9003 _ 0210 Nominal size 100 mm Case material stainless steel 1.4301 (AISI 304) Direct mounting, immersion tube bottom Immersion tube diameter 8 mm Immersion tube, stainless steel 1.4541 (AISI 321) Immersion length (L) customer specific Temperature range: 0 ... 100 °C Mechanical contact makes (NO) with clockwise pointer motion Option: Adjustable connection sliding on stem G½ 2015-10-13 Option: Customer specific immersion length Option: Customer specific immersion length L = 210 mm www.baumer.com Design and specifications subject to change without notice Ordering example with options Data sheet B22 T2.305 TSSE Page 4 / 5 TSSE Gas filled thermometer with contacts Ordering details TSSE Case Stainless steel 1.4301 (AISI 304) Type of mounting Direct mounting, immersion tube bottom Direct mounting, immersion tube center back Rear flange for wall mounting, immersion tube center back Every angle version, immersion tube bottom Every angle version, immersion tube center back Immersion tube diameter 6 mm 8 mm 9 mm 10 mm 11 mm 12 mm 14 mm 16 mm Immersion tube / material Stainless steel 1.4541 (AISI 321) Immersion tube / installed length L 100 mm 160 mm 250 mm 400 mm 600 mm 1000 mm Customer specific length (use option 9003_xxxx, xxxx = L in mm) Unit of measurement / Temperature ranges °C °F °C / °F (double scale) TSSE – 2 xx 6 . . xxx / TSSE 1 0 0 1 6 0 – 2 11 12 32 41 42 . 4 1 A B 2 C 7 D 6 2 4 6 7 8 9 0 . xxT xxU xxV Mechanical contacts (snap-action) Contact makes (NO) (1) Contact breaks (NC) (1) Changeover contact (SPDT) 1st contact makes / 2nd contact makes (NO/NO) (1) 1st contact makes / 2nd contact breaks (NO/NC) (1) 1st contact breaks / 2nd contact makes (NC/NO) (1) 1st contact breaks / 2nd contact breaks (NC/NC) (1) Double changeover contact (SPDT/SPDT) 1st contact makes / 2nd contact makes (NO/NO, separate circuits) (1) 1st contact makes / 2nd contact breaks (NO/NC, separate circuits) (1) 1st contact breaks / 2nd contact makes (NC/NO, separate circuits) (1) 1st contact breaks / 2nd contact breaks (NC/NC, separate circuits) (1) . 5001 5002 5003 5 0 11 5012 5021 5022 5033 5055 5056 5065 5066 Inductive contacts (Namur, DIN EN 60947-5-6) Contact makes (NO) (1) Contact breaks (NC) (1) 1st contact makes / 2nd contact makes (NO/NO) (1) 1st contact makes / 2nd contact breaks (NO/NC) (1) 1st contact breaks / 2nd contact makes (NC/NO) (1) 1st contact breaks / 2nd contact breaks (NC/NC) (1) Options to be added behind the / (see example page 4) 8001 8002 8 0 11 8012 8021 8022 / with clockwise pointer motion. 2015-10-13 (1) . xxxx Design and specifications subject to change without notice Model Gas filled thermometer with rigid stem and contacts Nominal size 100 mm 160 mm www.baumer.com Data sheet B22 T2.305 TSSE Page 5 / 5