CJ-series Controller Link Units
CJ1W-CLK
CSM_CJ1W-CLK_DS_E_6_3
New Controller Link Units, Now with
4,000 Send Words
• The Controller Link is an FA network that can send and
receive large amounts of data easily and at high speed.
The Controller Link supports data links that enable sharing
data between PLCs and computers and a message
service that enables sending and receiving data whenever
required.
• Systems can be flexibly built by using Repeater Units to
enable T-branches, long-distance wiring, and converting
part of the network to optical cable.
CJ1W-CLK23
Features
• Large-capacity data links are easily achieved without programming simply by setting data link tables.
• Up to 20,000 *1 send/receive words can be set per node for Units (up to 62,000 words for Boards).
• Data links can be performed with up to 4,000 *2 words per node while ensuring data concurrency.
• User-set data link tables can be changed while data links are operating. *3
• Errors for the entire system can be monitored by using error diagnosis support software and a variety of status flags.
*1. Supported for unit version 1.2 or later.
*2. CJ1W-CLK23 and 3G8F7-CLK@3 are supported.
*3. Supported for CJ1W-CLK23, 3G8F7-CLK@3, and models ending with "-V1".
System Configuration
Wired Controller Link Units
Basic Wiring (Daisy Chain Connection)
A
A
A
B
A
T-Branch Wiring, Partial Conversion to
Optical Cable
B
A
A
(1)
B
1km Max. *
(1)
Long-distance Wiring
A
D
D
A
A
(1)
C
(1)
B
A
(2)
A
C
D
A
(1)
(1)
1km Max. *
1km Max. *
1km Max. *
B
(1)
A: Wired Controller Link Unit
B: Wired Controller Link Support Board
C: Wire-to-Optical Repeater Unit
D: Wire-to-Wire Repeater Unit
* At 500 kbits/s
(1): Twisted-pair cable
(2): Optical cable
1
CJ1W-CLK
Ordering Information
International Standards
• The standards are abbreviated as follows: U: UL, U1: UL (Class I Division 2 Products for Hazardous Locations), C: CSA, UC: cULus, UC1: cULus (Class I Division 2
Products for Hazardous Locations), CU: cUL, N: NK, L: Lloyd, and CE: EC Directives.
• Contact your OMRON representative for further details and applicable conditions for these standards.
Controller Link Units
Specifications
Unit
classification
Product
name
Communications
cable
Communications
type
Wired shielded
twisted-pair
cable *
Data links and
message service
Duplex
support
Max. Units
mountable
per CPU
Unit
No. of unit
numbers
allocated
Current consumption
(A)
Model
5 V DC
Standards
24 V DC
Controller
Link
Unit
CJ1
CPU
Bus Unit
No
8
1
0.35
−
CJ1W-CLK23
UC1,N,L,
CE
Note: This unit cannot be used with the Machine Automation Controller NJ-series.
* Use the following special cable for shielded, twisted-pair cable.
• ESVC0.5×2C-13262 (Bando Electric Wire: Japanese Company)
• ESNC0.5×2C-99-087B (JMACS Japan Co., Ltd.: Japanese Company)
• ESPC 1P×0.5mm2 (Nagaoka Electric Wire Co.,Ltd.: Japanese Company)
• Li2Y-FCY2×0.56qmm (Kromberg & Schubert, Komtec Department: German Company)
• 1×2×AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)
• #9207 (Belden: US Company)
Accessories
There is no accessory for the CJ series Controller Link Unit.
Controller Link Support Boards
Specifications
Product name
Communications
cable
Communications
type
Controller Link Support
Board for PCI Bus
Wired shielded
twisted-pair cable
Data links and
message service
Accessories
Model
• CD-ROM ×1 *
• INSTALLATION GUIDE (W467) ×1 3G8F7-CLK23-E
• Communications connector ×1
Standards
CE
* The CD-ROM contains the following software.
• Controller Link (PCI) Driver
• FinsGateway Version 2003 (PCI-CLK Edition)
• FinsGateway Version 3 (PCI-CLK Edition)
• Setup Diagnostic Utility
• C Library
2
CJ1W-CLK
Repeater Units
Name
Specifications
Controller Link
Repeater Unit
CS1W-RPT
01
PWR
T/R1
T/R2
Model
Wire-to-Wire Model
CS1W-RPT01
Wire-to-Optical (H-PCF) Model *1
CS1W-RPT02
Wire-to-Optical (GI) Model *2
CS1W-RPT03
Standards
UC1,CE
SL1
TER SW
SW1
1 BAUD
2 RATE
ON
TER SW
SL2
DC24V
INPUT
Using Repeater Units enables T-branches and long-distance wiring for Wired Controller Link networks, 62-node configurations, and converting
part of the network to optical cable.
*1. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable with
connector.
*2. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).
Relay Terminal Block
Name
Specifications
Model
Standards
Relay Terminal Block for
Wired Controller Link Units
Used for Wired Controller Link Units (set of 5)
−
CJ1W-TB101
Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in advance
on the Unit in a Wired Controller Link network. Relay Terminal Blocks cannot be used on Controller Link Support Boards.
H-PCF Cables and Optical Connectors
Name
Application/construction
Specifications
1
2
3
4
Optical Fiber Cables
Optical
Connectors
(Crimp-cut)
Controller Link,
SYSMAC LINK,
SYSBUS
5
6
1. Optical fiber single-core cord
2. Tension member (plastic-sheathed
wire)
3. Filler (plastic)
4. Filler surrounding signal wires
(plastic, yarn, or fiber)
5. Holding tape (plastic)
6. Heat-resistant PV sheath
Two-core optical
cable with tension
member
Model
Black
10 m
S3200-HCCB101
Black
50 m
S3200-HCCB501
Black
100 m
S3200-HCCB102
Black
500 m
S3200-HCCB502
Black
1000 m
S3200-HCCB103
Orange
10 m
S3200-HCCO101
Orange
50 m
S3200-HCCO501
Orange
100 m
S3200-HCCO102
Orange
500 m
S3200-HCCO502
Orange
1000 m
S3200-HCCO103
Half lock
S3200-COCF2571
Full lock
S3200-COCF2071
Standards
−
CS1W-RPT02
H-PCF Optical Fiber Cables with Connectors (Black Composite Cables with Two-Optical Lines and Two
Power Supply Lines)
Application
Appearance
Model
Standards
S3200-CN@@@-20-20
Controller Link,
SYSMAC LINK
S3200-CN@@@-20-25
−
S3200-CN@@@-25-25
Optical connectors for H-PCF Optical Cables with Connectors are adhesive polished.
• Cable Length
The following cable lengths are available: 2 m, 5 m, 15 m, 20 m. For lengths of 21 m or more, contact your OMRON sales representative.
3
CJ1W-CLK
• Model Numbers
(1) 2 m, 5 m, 10 m, 15 m, or 20 m
(2) 21 m or longer
S3200-CN@@@
@@@-20-25
1.
2.
1. H-PCF
Optical Fiber Cable
S3200-CN-20-20
1.
3.
2. Cable length
@@@
Length
201
2m
501
5m
102
10 m
152
15 m
202
20 m
3. Specify the
cable length
in meters.
3. Connectors (both ends)
Number Connector lock
20
Full-lock
25
Half-lock
Cable length
• Optical Connector Assembly Tool
Name
Applicable Unit
Model
This tool is used on site for mounting crimp-cut
connectors and hard plastic-clad silica optical fiber
for optical transmission systems of C-series
SYSBUS, SYSMAC LINK, and Controller Link.
Optical Fiber
Assembly Tool
*
Manufacturer
Standards
Sumitomo Electric
Industries, Ltd.
CAK-0057
−
* There is a risk of quality problems when using cables assembled by typical users, so we recommend purchasing cables with preattached
connectors or having a qualified technician assemble the cables.
GI Optical Cables
A qualified technician must select, assemble, and install GI Optical Fiber Cable, so always let an optical cable specialist handle the GI cable.
Usable Optical Cables and Optical Connectors
• Optical fiber types: Graded, indexed, multi-mode, all quartz glass, fiber (GI-type AGF cable)
• Optical fiber construction (core diameter/clad diameter): 62.5/125 μm or 50/125 μm
• Optical fiber optical characteristics of optical fiber: Refer to the tables.
• Optical connector: ST connector (IEC-874-10)
• 50/125 μm AGF Cable
Item
Minimum
Numerical
Aperture (N.A)
−
Transmission
loss (dB)
−
Connection
loss (dB)
Transmission
bandwidth
(MHz-km)
−
500
• 62.5/125 μm AGF Cable
Standard
Maximum
−
−
Item
Minimum
−
Numerical
Aperture (N.A)
−
Transmission
loss (dB)
−
−
0.21
−
Conditions
3.0Lf
0.5 km ≤ Lf
3.0Lf+0.2
0.2 km ≤ Lf
≤ 0.5 km
3.0Lf+0.4
Lf ≤ 0.2 km
1.0
−
λ = 0.8 μm
Ta = 25°C
λ = 0.8 μm, one location
Connection
loss (dB)
λ = 0.85 μm (LD)
Transmission
bandwidth
(MHz-km)
Lf is fiber length in km, Ta is ambient temperature, and λ is the peak
wavelength of the test light source.
−
200
Standard
Maximum
Conditions
−
−
0.28
−
−
−
3.5Lf
0.5 km ≤ Lf
3.5Lf+0.2
0.2 km ≤ Lf
≤ 0.5 km
3.5Lf+0.4
Lf ≤ 0.2 km
1.0
λ = 0.8 μm, one location
−
λ = 0.8 μm
Ta = 25°C
λ = 0.85 μm (LD)
Lf is fiber length in km, Ta is ambient temperature, and λ is the peak
wavelength of the test light source.
4
CJ1W-CLK
Mountable Racks
NJ system
Model
CPU Rack
CJ1W-CLK23
Unit version 2.0
CJ1W-CLK21-V1 *1 Unit version 1.2
*1.
*2.
*3.
*4.
Expansion
Rack
Not supported
CJ1 system
CPU Rack
Expansion
Backplane
8 Units (per CPU Unit)
CP1H
system
NSJ system
CP1H PLC
NSJ
Controller
Expansion
Backplane
2 Units
*2
Not supported
*3
8 Units
*4
Discontinuation models in July 2012.
A CP1W-EXT01 CJ Unit Adaptor is required.
One NSJW-CLK21-V1 can be mounted to the NSJ Controller.
If an Expansion Rack is used, the NSJW-CLK21-V1 cannot be mounted to the NSJ Controller.
Communications Specifications
Items
Specifications
Model
CJ1W-CLK23
3G8F7-CLK23-E
CJ1W-CLK21-V1 *1
3G8F7-CLK21-EV1 *1
Type
Wired (shielded twisted-pair cable)
Communications method
N:N token-bus method
Code
Manchester code
Modulation
Baseband code
Synchronization
Flag synchronization (conforms to HDLC frames)
Transmission path format Multidrop method (bus type)
Transmission speed
Maximum transmission
distance
The following are the maximum transmission distances depending on the transmission speed.
2 Mbits/s: 500 m
1 Mbits/s: 800 m
500 kbits/s: 1 km
Maximum distance
between nodes
Not specified. (Maximum transmission distance must be satisfied for the entire system.)
Medium
Specified shielded twist-pair cable
Two signal wires, one shield
Node connection method
PLC: Connection to terminal block
Computer: Connection using special (supplied) connector
Maximum number of
nodes
32 or 62 nodes *2 *3
Applicable Programming
Devices
CX-Integrator in CX-One, CX-Net in CX-Programmer *3, and Programming Console
Communications
functions
Data links and message service
Number of data link words
Send words per node: 4,000 words max. (CJ1W-CLK@3), 1,000 words max. (All other Units)
Number of send/receive words per node: 12,000 words max. (Pre-Ver. 1.2)
20,000 words max. (unit Ver. 1.2 or later)
Total number of send words per network: 62,000 words max.
Data link areas
PLC: Bit areas (CIO Area, Work Area, Link Area *4), Data Memory (DM), Extended DM Area (EM) Computer:
FinsGateway event memory
Message length
2,012 bytes max. (including the header)
RAS functions
Error control
•
•
•
•
•
Polling node backup function
Self-diagnosis function (hardware checking at startup)
Echoback test and broadcast test (using the FINS command)
Watchdog timer
Error log function
Manchester code check
CRC check (CCITT X16+X12+X5+1)
*1. Discontinuation models in July 2012.
*2. With wired models, the maximum number of nodes is 32 if Repeater Units are not used. A Repeater Unit is required when building a network
with more than 32 nodes. If a Repeater Unit is used, be sure to use only the following Controller Link Units or Boards and set the Wired Network
62 Node Enable Bit in the DM Parameter Area software switches at all nodes.
CS1W-CLK23/CLK21-V1
CJ1W-CLK23/CLK21-V1
3G8F7-CLK23-E/CLK21-EV1
*3. CX-Net in CX-Programmer version 3.1 or earlier can be used only in a system with a maximum of 32 nodes (node address 1 to 32). If a system
is to be used with a maximum of 62 nodes (node addresses 1 to 62), use CX-Net in CX-Programmer version 3.2 or higher or the CX-Integrator.
*4. CJ-series PLCs do not have a Link Area, but LR000 to LR199 are automatically converted CIO 1000 to CIO 1199.
5
CJ1W-CLK
Individual Specifications
Controller Link Units
Item
Model
Applicable PLC
Number of mountable Units
Installation site
Storage location of network parameters
and manually set data link tables
Storage location of routing tables
Weight
Current consumption: 5 V in PLC
* Discontinuation models in July 2012.
Specifications
CJ1W-CLK23
CJ1W-CLK21-V1 *
All CJ-series CPU Units
8 max.
Install onto a CPU Backplane or Expansion Backplane (classified as a CPU Bus Unit).
System Bus Unit Area (in the CPU Unit parameter area).
CPU Unit parameter area
110 g
0.35 A
Controller Link Support Boards (for PCI Bus), New Models
Item
Specifications
3G8F7-CLK23-E
3G8F7-CLK13-E
3G8F7-CLK53-E
IBM PC/AT or compatible
• CPU: Intel Celeron 400 MHz or better
• Main memory: 128 MB minimum
• One or more PCI bus slots (PCI bus revision 2.0 or later, power supply: 5 V)
Computer-compatible models
• Free hard disk space: 70 MB min.
• CD-ROM drive: One required for installation
• Display: VGA (640 x 480 (pixels) min.)
(Other conditions conform to the OS.)
• FinsGateway Version2003 *1
Windows 7 (32bit) Professional
Windows 7 (32bit) Home Premium
Windows Vista Business
Windows Vista Home Premium
Windows XP Professional
Windows XP Home Edition
Compatible OS
Windows 2000 Professional
• FinsGateway Version3 *2
Windows XP Professional
Windows XP Home Edition
Windows 2000 Professional
Windows NT4.0 (Service Pack 3 or higher)
Windows ME
Windows 98SE
120 g
124 g
Weight
104 g
(excluding mounting bracket)
(excluding mounting bracket)
5 V in PLC
0.35 A
0.54 A
0.60 A
Current consumption
External 24 V
−
0.35 A
0.35 A
*1. Install the software from CD Ver. 3.10 or higher if the operating system is Windows 7 (32bit) or Windows Vista.
*2. Install FinsGateway version 3 if the operating system is Windows NT 4.0 (Service pack 3 or higher), Windows ME, or Windows 98SE. In that
case, however, the new functions of Controller Link Support Boards for the PCI Bus cannot be used (i.e., automatic data link creation with 1:N
allocation, changing data link tables with active data links, 62-node setting for wired models, and maximum of 4000 send words).
Model
Controller Link Support Boards (for PCI Bus), Old Models
Item
Model *1
Computer-compatible models
Compatible OS *2
Weight
Specifications
3G8F7-CLK21-EV1
3G8F7-CLK12-EV1
3G8F7-CLK52-EV1
IBM PC/AT or compatible
• CPU: Intel Celeron 400 MHz or better
• Main memory: 128 MB minimum
• One or more PCI bus slots (PCI bus revision 2.0 or later, power supply: 5 V)
• Free hard disk space: 70 MB min.
• CD-ROM drive: One required for installation
• Display: VGA (640 x 480 (pixels) min.)
(Other conditions conform to the OS.)
• FinsGateway Version2003
Windows XP Professional
Windows XP Home Edition
Windows 2000 Professional
• FinsGateway Version3
Windows XP Professional
Windows XP Home Edition
Windows 2000 Professional
Windows NT4.0 (Service Pack 3 or higher)
Windows ME
Windows 98SE
120 g
124 g
104 g
(excluding mounting bracket)
(excluding mounting bracket)
0.35 A
0.54 A
0.60 A
−
0.35 A
0.35 A
5 V in PLC
External 24 V
*1. Discontinuation models in July 2012.
*2. Install FinsGateway version 3 if the operating system is Windows NT 4.0 (Service pack 3 or higher), Windows ME, or Windows 98SE. In that
case, however, the new functions of Controller Link Support Boards for the PCI Bus cannot be used (i.e., automatic data link creation with 1:N
allocation, changing data link tables with active data links, 62-node setting for wired models, and maximum of 4000 send words).
Current consumption
6
CJ1W-CLK
Repeater Units
Item
Model
Supported Units/Boards
Transmission line
Transmission line format
Installation
Weight
Allowable power supply
voltage range
Current consumption
Inrush current
Specifications
CS1W-RPT01
CS1W-RPT02
CS1W-RPT03
All wired Controller Link Units and Boards
Note: If a maximum of 62 nodes is used, models that support 62 nodes must be used.
Wire-to-wire
Wire-to-optical (H-PCF)
Wire-to-optical (GI)
Multi-drop
1:1 type
1:1 type
Tree
Repeater Units are not mounted to the PLC. They are mounted separately with screws or on a DIN Track.
126 g
113 g (excluding mounting bracket) 116 g (excluding mounting bracket)
20.4 to 26.4 V DC (24 V DC −15 to 10%)
24 V DC at 0.06 A
2.5 A max. at 24 V DC (5 ms after startup)
24 V DC at 0.07 A
Repeater Units are used to expand the Controller Link network for wired models. For Wired-to-optical Repeater Units, always use a set of two (1:1).
Optical Ring Controller Link Units and Boards cannot be connected to the optical cable section between Repeater Units.
External Interface
CJ1W-CLK23/CJ1W-CLK21-V1 *
CLK21-V1
RUN ERC
INS
SD
TER ERH M/A LNK
RD
EF012
6789
345
ABCD
901
456
23
LED Indicators
Display the Unit and network status.
UNIT
No.
Unit Number Switch
One rotary switch. The unit number of the Unit on the PLC is set in single-digit
hexadecimal.
NODE
No.
x101
Node Address Switches
Two rotary switches. The node address of the Unit on the Controller Link Network is
set in 2-digit decimal.
78
901
78
ON
1 2
ON
0
x10
1 BAUD
2 RATE
ON
SW1
456
23
Baud Rate Switches
A two-pin DIP switch. The following setting is made.
Pins 1 and 2: Baud rate
TER SW
BD H
Terminating Resistance Switch
A slide switch. Use this switch to set the terminating resistance to ON for nodes at
both ends of the Controller Link Network.
BD L
SHLD
Terminal Block for the Communications Cable
Terminals to connect to the Controller Link Network communications cable
(twisted-pair cable).
* Discontinuation models in July 2012.
Definition of Terminal Block Pin Names for Communications Cables
Marking
Notation
Signal name
Line color
■
BD H
Communication data, high
Black
@
BD L
Communication data, low
White
None
SHLD
Shield
None
Crimp Terminals
Use crimp terminals (M3) having the dimensions shown below.
6.2 mm max.
6.2 mm max.
7
CJ1W-CLK
Differences in Specifications of New and Old Models
Controller Link Units
Functions
CJ1W-CLK23
CJ1W-CLK21-V1
The following models are
discontinued.
CJ1W-CLK21-V1
The following models are
discontinued.
CJ1W-CLK21
The following models are
discontinued.
Unit version 2.0
Unit version 1.2
Pre-Ver. 1.2
Pre-Ver. 1.2
Number of data link send
words (data link areas that are
created for a single node in a
single PLC)
20,000 max.
Number of send words per
node (total of area 1 and area
2)
4,000 words max.
(user-set links only)
Data Link Area
Allocation setting can be performed for same areas in Allocation setting can be performed for same areas in
areas 1 and 2.
areas 1 and 2.
12,000 max.
1,000 words max.
Max. Units mountable per PLC 8 Units
Automatic data link setting
4 Units
Supported for equality
layout only.
Choose from equality layout or 1:N allocations (common type, 1:1, chain type)
Changing data link allocations
Supported (Data link tables can be changed during active data links.)
during active data links
Not supported.
Maximum connectable nodes
62 nodes *1
32 nodes
Mixed use
Yes *2
Compatible support software
CX-Integrator for CX-One
CX-Net for
V2.1or higher, or CX-Net
CX-Programmer Ver. 5.0
for CX-Programmer Ver.
or higher
7.2 or higher
CX-Net for
CX-Programmer Ver. 3.2
or higher
CX-Net for
CX-Programmer Ver. 1.0
or higher
*1. For wired models, the maximum number of nodes is 32 if Repeater Units are not used.
*2. Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications for the
old models. The data link send/receive words can be separately set to their maximums when new and old models are mixed.
Controller Link Support Boards (for PCI Bus)
Functions
3G8F7-CLK23-E
Number of data link send/
receive words (data link areas
for sending/receiving that are
created for a single node in a
single computer)
62,000 max.
Send words per node
4,000 words max.
(user-set links only)
3G8F7-CLK21-EV1
The following models are
discontinued.
3G8F7-CLK21-E
The following models are
discontinued.
32,000 max.
1,000 words max.
Changing data link allocations
Supported. (Data link tables can be changed during active data links.)
during active data links
Not supported.
Maximum connectable nodes
62 nodes *1
32 nodes
Mixed use
Yes *2
Compatible FinsGateway *3
FinsGateway Version 2003.21 or
higher (In CD Ver. 3.00 or higher)
FinsGateway Version 2003.00 or
higher (In CD Ver. 2.00 or higher)
FinsGateway Version 3.00 or
higher (In CD Ver. 1.00 or higher)
Compatible support software
CX-Integrator for CX-One Ver. 2.1
or higher , or CX-Net for
CX-Programmer Ver. 7.2 or higher
CX-Net for CX-Programmer Ver.
3.2 or higher
CX-Net for Ver. 1.0 or higher
*1. For wired models, the maximum number of nodes is 32 if repeater units are not used.
*2. Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications for the
old models. The data link send/receive words can be separately set to their maximums when new and old models are mixed.
*3. FinsGateway Version 2003 is compatible with Windows 7 (32bit) (CD Ver.3.10 or higher), Windows Vista (CD Ver.3.10 or higher), Windows
XP and Windows 2000. For Windows NT4.0 (Service Pack 3 or higher), Windows ME, or Windows 98SE, use FinsGateway Version3. (With
FinsGateway Version 3, only functions supported by the 3G8F7-CLK21 can be used.)
8
CJ1W-CLK
Usage Precautions
• Old models and new models can be used mixed on the same network. In that case, however, build the system using the specifications for the
old models. The data link send/receive words can be separately set to their maximums when new and old models are mixed.
• Repeater Units can be used to expand a Wired Controller Link Network. For Wired-to-optical Repeater Units, always use a set of two (1:1).
Optical Ring Controller Link Units and Boards cannot be connected to the optical cable section between Repeater Units.
• Connect Repeater Units so that there are no more than two stages between any two nodes. One set of two Wire-to-Optical Repeater Units is
counted as one stage.
Dimensions
(Unit: mm)
CJ1W- CLK23/ CJ1W- CLK21-V1 *
65
2.7
90
2.7
82
31
* Discontinuation models in July 2012.
9
CJ1W-CLK
Related Manuals
Cat.No
Model
Name
Applications
Description
W309
CS1W-CLK23
CS1W-CLK21-V1
CJ1W-CLK23
CJ1W-CLK21-V1
C200HW-CLK21
CVM1-CLK21
CQM1H-CLK21
CS1W-RPT01/02/03
Controller Link Units Operation Manual
W422
3G8F7-CLK12-V1
3G8F7-CLK52-V1
3G8F7-CLK21-V1
Used when information
Controller Link Support Boards for PCI Bus regarding setup procedures Describes the setup method for
Installation Guide
for Controller Link Support the Controller Link Support Boards
(3G8F7-CLK12/21/52-V1)
Boards for PCI bus
for PCI bus connections.
connections is needed.
W467
3G8F7-CLK13
3G8F7-CLK12-V1
3G8F7-CLK53
3G8F7-CLK52-V1
3G8F7-CLK23
3G8F7-CLK21-V1
Used when information
Controller Link Support Board for PCI Bus regarding setup procedures Describes the setup method for
Installation Guide
for Controller Link Support the Controller Link Support Boards
(3G8F7-CLK13/12-V1/53/52-V1/23/21-V1) Boards for PCI bus
for PCI bus connections.
connections is needed.
W383
3G8F7-CLK13
3G8F7-CLK12-V1
3G8F7-CLK53
3G8F7-CLK52-V1
3G8F7-CLK23
3G8F7-CLK21-V1
Used when information
regarding setup procedures Describes the setup method for
Controller Link Support Boards for PCI Bus
for Controller Link Support the Controller Link Support Boards
Operation Manual
Boards for PCI bus
for PCI bus connections.
connections is needed.
W464
CXONE-AL@@D-V@
CX-Integrator Operation Manual
Used when network setup
or network monitoring
needs to be performed.
Describes the operating
procedures for the CX-Integrator.
CXONE-AL@@D-V@
CX-One FA Integrated Tool Package
Setup Manual
Used when installing
software from the CX-One.
Provides an overview of the FA
Integration Tool Package CX-One,
and describes the CX-One
installation procedures.
W463
Used when information
regarding operating
procedures for Wired
Controller Link Units is
needed.
Describes operating procedures
for Controller Link Units. Controller
Link Units can connect to Wired
Controller Link Units.
10
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2016.4
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2016 All Right Reserved.