PLC Interfaces H-, R- and S-System Contents PLC Interfaces H-, R- and S-System PLC Interfaces Universal Precabling for PLCs B.2 Selection Guide B.5 Direct Inputs / Outputs for Digital Cards B.21 Opto-Decoupled Inputs for Digital Cards B.39 Relay Outputs for Digital Cards B.42 Input/Output for Analog Cards B.54 B.1 B PLC Interfaces H-, R- and S-System Universal Precabling for PLCs B PLC interface systems The complexity of machines and installations in industry, processing or building is giving rise to ever-increasing cabling costs. The traditional wire to wire cabling between the PLC and the inputs/outputs is very expensive during installation and commissioning. The PLC interface system offers the user an easy and quick-to-install solution for wiring the inputs and outputs of the SIEMENS SIMATIC® S7. Wire to wire cabling Wiring interface system Most PLC I/O cards use two types of connection: The basic idea is that the PLC’s I/O cards are connected to the active or passive I/O modules using prefabricated cables. Front adapters are directly plugged into the PLC’s I/O cards. The adapter internally converts the PLC-specific connectors to an HE connector for ribbon cable (in accordance with IEC 603-1/ DIN 41651). The active or passive I/O modules can thus be used independently of the type of PLC. • screw, • tension clamp. In each case, the signals are connected individually to each connection component. Disadvantages of wire to wire cabling: Special front adapters replace the usual screwed connectors used for the I/O cards of the PLC. The signals from the PLC are sent to the active or passive components by means of a prefabricated lead fitted with a 20-pole female connector. • high assembly costs, • risk of error increasing with the number of wires connected, The wiring interface system has the following advantages over wire to wire cabling: • large amount of space taken up in the cabinet, • minimum wiring costs, • high installation costs, • the commissioning and the production of wiring drawings is simplified. • a lot of time taken up in preparing and laying the wires, • a large amount of time taken up in producing wiring diagrams and drawings. • reduced installation time, The family of PLC interface modules allows the inputs/outputs for main PLC manufacturers to be quickly and easily connected. PLC PLC B.2 PLC Interfaces H-, R- and S-System Universal Precabling for PLCs PLC interface systems Advantages of the system: • Quick – reduced design times, – time saved during installation, – reduced commissioning and troubleshooting times, B Inputs • Reliable Outputs – reduced on-site wiring times thanks to the prefabricated cables. – no wiring errors, – clear wiring in the cabinet (cable system instead of individual wires), – labelling corresponding to that of the PLC, – additional individual labelling. • Flexible – many input/output modules (about 40 possibilities), – variable cable lengths, – modularity of all components, – configuration of 1 x 4 bytes and 2 x 2 bytes without distributor, – option to mix functions by byte at the I/Os, – extensions possible without any problem, – flexibility thanks to the ease in exchanging input/output interfaces. • Takes up only a small amount of space – more space in the cable ducts, – narrow modules, – no terminal block. B.3 PLC Interfaces H-, R- and S-System Universal Precabling for PLCs Weidmuller universal precabling for PLCs System H ... … screw or tension clamp, standard or compact B Weidmuller’s system H was developed for all PLC types and can be adapted to suit all situations. Particularly economic, it is characterized by: Connector type HE, 10/20 pins, fully protected: extruded-insulation cable, polarized, secure connection precabling to PLC – 0.25 mm2 (LIYY) Relay outputs – System H connection type selection: screw or tension clamp new compact modules, reducing the size of the cabinet Input/output of interface modules boards for digital signals: 4, 8, 12, 16 and 32-channel System R … … with the RSV 1.6 industrial connector Thanks to its industrial connector, system R enables the connection of input signals to a higher voltage of up to 160 V or 250 V. It is characterized by: connector type RSV 1.6 (250 V DC 8 A) precabling to PLC – 0.25 mm2 (LIYY) input/output interface module boards for digital signals 8, 16, 32-channel Direct inputs – System R System S … … with shielded Sub-D connector The sub-d metallic housing is ideal for the transmission of analog signals: Connector sub-d female 15, 25, 37 poles Precabling to PLC – 0.25 mm2 shielded (LYC) Input/output interface module boards with PE. Analog input/outputs – System S B.4 EVEN SIMPLER TO USE … … thanks to the new “Selection guide” available on CD or download This new guide available on CD or from our Web site enables you to make rapid searches for interface modules and compatible cables for a PLC and to display the corresponding technical data. PLC Selection Guide • PLC selection • I/O card selection • Displays all interface modules and the compatible cable • Displays the technical data for the selected interface module and ribbon cable B Download Selection Guide http://www.weidmuller.com Using the selection guide PLC Interfaces H-, R- and S-System Selection guide Select the PLC card from the corresponding table Look up the order number for the cable and the quantity to be ordered PLC Siemens - S7-300 PLC Cables I/O cards Standard Digital input Manufacturer order number H , R and S System C Qty Order No. 7789234xxx 7789236xxx 7789247XXX 7789212xxx 7789234xxx 7789210xxx 7789219xxx 7789215xxx 7789211xxx 7789234xxx 7789234xxx 7789236xxx 7789246XXX 7789246XXX 7789211xxx 7789239xxx 7789219xxx 7789220xxx 7789239xxx 7789214xxx 7789211xxx 7789190xxx 7789191xxx 7789192xxx 7789192xxx 7789237xxx 7789236xxx 7789221xxx 7789222xxx 7789222xxx 7789222xxx 7789223xxx 6ES7 314-6CF00-0AB0 (314C-2DP) 7789222xxx 7789223xxx 6ES7 314-6BF00-0AB0 (314C-2PtP) 7789222xxx 7789223xxx 7789229xxx 6ES7 331-7KF01-0AB0 7789231xxx 6ES7 331-7NF00-0AB0 7789193xxx 6ES7 331-7RD00-0AB0 7789194xxx 6ES7 331-7RD00-0AB0 7789229xxx 6ES7 331-7SF00-0AB0 7789230xxx 6ES7 331-7PF00-0AB0 6ES7 331-7KB01 / 7KB81-0AB0 7789224xxx 7789228xxx 6ES7 332-5HD01-0AB0 7789227xxx 6ES7 332-5HD01-0AB0 6ES7 332-5HB01 / 5HB81-0AB0 7789228xxx 6ES7 332-5HB01 / 5HB81-0AB0 7789227xxx 7789228xxx 6ES7 332-7ND00-0AB0 7789227xxx 6ES7 332-7ND00-0AB0 7789195xxx 6ES7 332-5RD00-0AB0 7789233xxx 6ES7 332-5HF00-0AB0 7789196xxx 6ES7 334-0KE00-0AB0 7789226xxx 6ES7 335-7HG01-0AB0 7789225xxx 6ES7 334-0CE01-0AA0 6ES7 321-1BH01 / 1BH81-0AA0 6ES7 321-1BL00 / 1BL80-0AA0 6ES7 321-1BP00-0AA0 6ES7 321-1EH01-0AA0 6ES7 321-1BH50-0AA0 6ES7 321-7BH00 / 7BH80-0AB0 6ES7 321-1FF01 / 1FF81-0AA0 6ES7 321-1EL00-0AA0 6ES7 321-1CH80-0AA0 6ES7 321-7RD00-0AB0 6ES7 322-1BH01 / 1BH81-0AA0 6ES7 322-1BL00-0AA0 6ES7 322-1BP00-0AA0 6ES7 321-1BP50-0AA0 6ES7 322-1EH01-0AA0 6ES7 322-1BF01-0AA0 6ES7 322-1FF01 / 1FF81-0AA0 6ES7 322-1HF01-0AA0 6ES7 322-8BF00-0AB0 6ES7 322-1HH00-0AA0 6ES7 322-1EL00-0AA0 6ES7 322-1HF10 / 1HF80-0AA0 6ES7 322-1CF80-0AA0 6ES7 322-5SD00-0AB0 6ES7 322-5RD00-0AB0 6ES7 323-1BH00 / 1BH80-0AA0 6ES7 323-1BL00-0AA0 6ES7 312-5BD00-0AB0 (312C) 6ES7 313-6CE00-0AB0 (313C-2DP) 6ES7 313-6BE00-0AB0 (313C-2PtP) 6ES7 313-5BE00-0AB0 (313C) Interfaces 1 1 2 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Order No. Digital output Digital I/O I/O cards 7789293xxx 7789293xxx 1 2 7789293xxx 1 7789293xxx 7789293xxx 1 2 ital input Digital and Anal. I/O Anal. Input Anal. Output Anal. I/O Digital relay output - see page C.42 - 7789293xxx 6ES7 321-1BH01 / 1BH81-0AA0 6ES7 321-1BL00 / 1BL80-0AA0 6ES7 321-1BP00-0AA0 6ES7 321-7BH00 / 7BH80-0AB0 Qty Type 16-channel - H 32-channel - H 32-channel - H 16-channel - R 16-channel - H 16-channel - R 8-channel - R 32-channel - R 16-channel - R 16-channel - H B) A, B) 16-channel 16-channel ) Qty B) B) Type Order No. Type Qty 1 2 2 16-channel 32-channel 32-channel 32-channel 16-channel - R 16-channel - R 16-channel - R 8-channel - R 8-channel - H 8-channel - H 8-channel - H 16-channel - H 12-channel - H 16-channel - H 16-channel - H 16-channel - H 8-channel - H 16-channel - H 8-channel - H 16-channel - H 8-channel - H Anal. input/output C) 1 1 A, C) Example: • Cable order number 7789236xxx* - Qty 1 * see the note at the bottom of the page A, C) A, C) 1 8-channel 1 8-channel 1 8-channel 16-channel 8-channel 16-channel 16-channel 16-channel 1 1 1 1 1 1 1 1 D) 1 2 D) 1 Cables 1 1 1 1 1 1 1 1 1 1 1 1 1 1 E) 7789234xxx 7789236xxx 7789247XXX 1 1 2 7789212xxx 7789234xxx 1 1 7789210xxx 1 Int SITOP 1Connection 16-channel Qty E) 1 2 16-channel 16-channel 7789293xxx 1 1 16-channel - H 8-channel P 32-channel -1H 8-channel P 32-channel -1H 8-channel 16-channel 4-channel 4-channel 8-channel 8-channel 4-channel 4-channel 4-channel 4-channel 4-channel 4-channel 4-channel 4-channel 8-channel 8-channel 16-channel 16-channel 1 - see page C.38 - Qty Type 8-channel P 1 Digital optodecoupled input - see page C.20 - Qty Order No. 7789293xxx 7789293xxx Digital Direct I/Os B) A, B) 1 1 A, B) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Q Type 16-channel 16-channel B) 16-channel - R 16-channel - H 1 1 16-channel - R 1 Look up the exact module family and the quantity to be ordered B) Example: • 32-channel system H - Qty. 1 or • 16-channel opto-decoupled system H - Qty. 2 ) Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 metres in length: Order number: 7 7 8 9 2 3 6 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use Module either a digitaloverview direct input/output module or an opto-decoupled input module - Direct inputs/outputs for digital Example: • PLC: Siemens S7-300 • Card: 6ES7 321-1BL00 / 1BL80-0AA0 - see page C.54 - Qty 1 1 1 1 1 1 1 Standard 2 Type 1 1 A, B) 16-channel - R 8-channel - R 16-channel - R Manufacturer order number 6ES7 321-1EH01-0AA0 6ES7 321-1BH50-0AA0 Digital optodecoupled input - see page C.38 - Qty PLC Siemens - S7-300 PLC Digital Direct I/Os - see page C.20 - SITOP Connection cards Refer to the page whose number is given at the top of the column C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) Example: • Please refer to page B.21 Direct inputs/outputs for digital cards PLC Interfaces H-, R- and S-System E) Two channels unused * All I/O signals with same common. * Addional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com C.6 Type No. of channels 8 channels 12 chan. Functionalities Type of wiring 2-wire V R System 2-wire V 2-wire V L V V L H System C Compact version Connection H or R System H System Screw C C C C 2-wire 16 channels 3-wire V V V C V C C V V V V V V V V 1-wire R System 2-wire 3-wire C C V V C V V C V 1-wire H System 2-wire 32 channels 3-wire 1-wire 1 LED per chan. Disconnectable Order No. Fuse L Type 9445530000 RS 8ES-D-L H/V 9441540000 (*) RS8ES-DP RSV1,6/V Page C.21 V C.21 3-wire 1-wire H System Tension c. Modules C C V V V V V V 9445630000 RS 12ES-D-L H/V 9445700000 Z Z Z Z Z 9447700000 L L L L L L I I I Z Z F RS 16ES H/Z C.23 C.23 9445810000 RS 16ES-S-I-L H/V C.23 9445720000 RS 16ES-D H/V C.24 9445730000 RS 16ES-D-L H/V C.24 9447730000 RS 16ES-D-L H/Z H System C.24 9445750000 RS 16ES-D-I-L H/V I I I L L I F C.24 C.25 9445760000 C.25 9445770000 C.25 RS 16ES-T-L H/Z 9441500000 RS16ES RSV1,6/V 9441860000 RS16ES-I RSV1,6/V 9441700000 RS16ES-DP RSV1,6/V 9441560000 RS16ES-DP/F RSV1,6/V C.25 3-wireC.26 C.26 C C V V C C C C V V V V V V C.27 C.27 1-wireC.28 9445900000 RS 32ES H/V C.29 9445910000 RS 32ES-L H/V C.29 9447900000 (*) RS 32ES H/Z L L L L L L C.24 2-wire 944582000032RS 16ES-D-F H/V 9441600000 (*) RS16E-3E/I RSV1,6/V L C.23 1-wireC.23 RS 16ES-L H/Z 9447770000 9441600000 RS16E 3E/I RSV1,6/V C.28 9445900000 RS 32ES H/V C.29 9445910000 RS 32ES-L H/V C.29 C.22 9447710000 RS 16ES-T H/V channelsRS 16ES-T-L H/V L L I Z RS 16ES-L H/V (*) 9447750000 (*) RS 16ES-D-I-L H/Z F I Z Z RS 16ES H/V 9445710000 I V V C.29 9447910000 RS 32ES-L H/Z 9445870000 RS 32ES-S-I-L H/V C.30 9445930000 RS 32ES-D-L H/V C.31 C.29 9447930000 RS 32ES-D-L H/Z 9445950000 RS 32ES-D-I-L H/V C.32 9447950000 (*) RS 32ES-D-I-L H/Z C.32 Z Z Z Z Z L 9447900000 (*) RS 32ES H/Z L L L L L L I I I L L I F C.29 9447910000 RS 32ES-L H/Z 9445870000 RS 32ES-S-I-L H/V C.30 9445930000 RS 32ES-D-L H/V C.31 9447930000 RS 32ES-D-L H/Z 9445950000 RS 32ES-D-I-L H/V C.32 9447950000 (*) RS 32ES-D-I-L H/Z C.32 C.29 C.31 9445980000 RS 32ES-D-F H/V C.33 9445960000 RS 32ES-T H/V C.34 9445970000 RS 32ES-T-L H/V C.34 9447970000 RS 32ES-T-L H/Z C.34 9441510000 RS32ES RSV1,6/V C.35 9441870000 RS32ES I RSV1 6/V C 35 Select the module order number in the family defined at stage 3 C.31 9445980000 RS 32ES-D-F H/V C.33 9445960000 RS 32ES-T H/V C.34 9445970000 RS 32ES-T-L H/V C.34 9447970000 RS 32ES-T-L H/Z C.34 9441510000 RS32ES RSV1,6/V C.35 9441870000 RS32ES-I RSV1,6/V C.35 * The suffix xxx in the order number shows the length of the cable in dm. the standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 4.00 m (040) - 5.00 m (050). PLC Interfaces H-, R- and S-System Selection Guide Example: • Module order number 9445950000 – Qty. 1 32-channel module, 2-wire cabling, compact, version with Led, interruptible • Technical characteristics, page B.33 Note: it is also possible to use the catalog type of the cable. In this case the suffix xxxx of the catalog type shows the length of the cable in cm. The standard lengths are: 1.00 m (0100) – 1.50 m (0150) – 2.00 m (0200) - 3.00 m (0300) – 4.00 m (0400) – 5.00 m (0500) B.5 PLC Interfaces H-, R- and S-System Selection Guide PLC Siemens - S7-300 PLC I/O cards Cables Standard Interfaces Digital Direct I/Os SITOP Connection - see page B.21 - Digital input Manufacturer order number Anal. I/O Anal. Output Anal. Input Digital and Anal. I/O Digital I/O Digital output B Order No. 7789234xxx 7789236xxx 7789247xxx 7789212xxx 7789234xxx 7789210xxx 7789219xxx 7789215xxx 7789211xxx 7789234xxx 7789234xxx 7789236xxx 7789246xxx 7789246xxx 7789211xxx 7789239xxx 7789219xxx 7789220xxx 7789239xxx 6ES7 322-8BF00-0AB0 7789214xxx 6ES7 322-1HH00-0AA0 7789211xxx 6ES7 322-1EL00-0AA0 6ES7 322-1HF10 / 1HF80-0AA0 7789190xxx 7789191xxx 6ES7 322-1CF80-0AA0 7789192xxx 6ES7 322-5SD00-0AB0 7789192xxx 6ES7 322-5RD00-0AB0 6ES7 323-1BH00 / 1BH80-0AA0 7789237xxx 7789236xxx 6ES7 323-1BL00-0AA0 7789221xxx 6ES7 312-5BD00-0AB0 (312C) 6ES7 313-6CE00-0AB0 (313C-2DP) 7789222xxx 6ES7 313-6BE00-0AB0 (313C-2PtP) 7789222xxx 7789222xxx 6ES7 313-5BE00-0AB0 (313C) 7789223xxx 6ES7 314-6CF00-0AB0 (314C-2DP) 7789222xxx 7789223xxx 6ES7 314-6BF00-0AB0 (314C-2PtP) 7789222xxx 7789223xxx 7789229xxx 6ES7 331-7KF01-0AB0 7789231xxx 6ES7 331-7NF00-0AB0 7789193xxx 6ES7 331-7RD00-0AB0 7789194xxx 6ES7 331-7RD00-0AB0 7789229xxx 6ES7 331-7SF00-0AB0 7789230xxx 6ES7 331-7PF00-0AB0 6ES7 331-7KB01 / 7KB81-0AB0 7789224xxx 7789228xxx 6ES7 332-5HD01-0AB0 7789227xxx 6ES7 332-5HD01-0AB0 6ES7 332-5HB01 / 5HB81-0AB0 7789228xxx 6ES7 332-5HB01 / 5HB81-0AB0 7789227xxx 7789228xxx 6ES7 332-7ND00-0AB0 7789227xxx 6ES7 332-7ND00-0AB0 7789195xxx 6ES7 332-5RD00-0AB0 7789233xxx 6ES7 332-5HF00-0AB0 7789196xxx 6ES7 334-0KE00-0AB0 7789226xxx 6ES7 335-7HG01-0AB0 7789225xxx 6ES7 334-0CE01-0AA0 6ES7 321-1BH01 / 1BH81-0AA0 6ES7 321-1BL00 / 1BL80-0AA0 6ES7 321-1BP00-0AA0 6ES7 321-1EH01-0AA0 6ES7 321-1BH50-0AA0 6ES7 321-7BH00 / 7BH80-0AB0 6ES7 321-1FF01 / 1FF81-0AA0 6ES7 321-1EL00-0AA0 6ES7 321-1CH80-0AA0 6ES7 321-7RD00-0AB0 6ES7 322-1BH01 / 1BH81-0AA0 6ES7 322-1BL00-0AA0 6ES7 322-1BP00-0AA0 6ES7 321-1BP50-0AA0 6ES7 322-1EH01-0AA0 6ES7 322-1BF01-0AA0 6ES7 322-1FF01 / 1FF81-0AA0 6ES7 322-1HF01-0AA0 Qty 1 1 2 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Order No. 7789293xxx 7789293xxx Qty 1 2 7789293xxx 1 7789293xxx 7789293xxx 1 2 7789293xxx 2 Digital relay output - see page B.39 - - see page B.42 - Qty Type 16-channel - H 32-channel - H 32-channel - H 16-channel - R 16-channel - H 16-channel - R 8-channel - R 32-channel - R 16-channel - R 16-channel - H Digital optodecoupled input B) A, B) A, B) 1 1 2 1 1 1 1 1 1 1 Qty Type 16-channel 16-channel B) B) Type 1 8-channel - R 16-channel - R 1 1 16-channel - R 16-channel - R 16-channel - R 8-channel - R 8-channel - H 8-channel - H 8-channel - H 16-channel - H 12-channel - H 16-channel - H 16-channel - H 16-channel - H 8-channel - H 16-channel - H 8-channel - H 16-channel - H 8-channel - H D) D) E) 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Qty - see page B.54 Type Qty 8-channel P 1 8-channel P 1 8-channel P 8-channel 16-channel 4-channel 4-channel 8-channel 8-channel 4-channel 4-channel 4-channel 4-channel 4-channel 4-channel 4-channel 4-channel 8-channel 8-channel 16-channel 16-channel 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 ) 16-channel 32-channel 32-channel 32-channel 16-channel - R Analog input/output 16-channel 1 C) A, C) 1 1 A, C) A, C) 8-channel 1 8-channel 1 8-channel 16-channel 8-channel 16-channel 16-channel 16-channel 1 1 1 1 1 1 E) 16-channel 1 16-channel 1 Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 2 3 6 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) E) Two channels unused * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.6 PLC Siemens - S7-400 PLC I/O cards Cables Standard Interfaces Digital Direct I/Os SITOP Connection - see page B.21 - Anal. O Anal. Input Digital output Digital input Manufacturer order number 6ES7 421-1BL00-0AA0 6ES7 421-1EL00-0AA0 6ES7 421-1FH00-0AA0 6ES7 421-7DH00-0AB0 6ES7 421-7BH00-0AB0 6ES7 421-1FH20-0AA0 6ES7 422-1BH10-0AA0 6ES7 422-1BL00-0AA0 6ES7 422-1FF00-0AA0 6ES7 422-1FH00-0AA0 6ES7 422-1HH00-0AA0 6ES7 422-5EH10-0AB0 6ES7 422-7BL00-0AB0 6ES7 431-1KF00-0AB0 6ES7 431-1KF00-0AB0 6ES7 431-1KF10-0AB0 6ES7 431-1KF20-0AB0 6ES7 431-7QH00-0AB0 6ES7 431-0HH00-0AB0 6ES7 432-1HF00-0AB0 Order No. Qty 7789292xxx 7789278xxx 7789273xxx 7789278xxx 7789290xxx 7789273xxx 7789291xxx 7789292xxx 7789283xxx 7789273xxx 7789270xxx 7789291xxx 7789292xxx 7789287xxx 7789286xxx 7789285xxx 7789285xxx 7789284xxx 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7789284xxx 7789288xxx 1 1 Order No. 7789293xxx 7789293xxx Qty 2 Digital relay output - see page B.39 - - see page B.42 - Qty Type 32-channel - H 32-channel - R 16-channel - R 32-channel - R 16-channel - H 16-channel - R Digital optodecoupled input A, B) D) 1 1 1 1 1 1 Type 16-channel 2 8-channel - R 16-channel - R 32-channel - R Qty B) Type Analog input/output Qty - see page B.54 Type Qty 2 B 16-channel 32-channel C) 16-channel C, F) 32-channel A,C) C) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8-channel 8-channel 8-channel 8-channel 16-channel 16-channel 8-channel Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 2 9 2 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil) * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com PLC Interfaces H-, R- and S-System Selection Guide B.7 PLC Interfaces H-, R- and S-System Selection Guide PLC Télémécanique - Micro PLC I/O cards Cables Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Digital output Digital input Manufacturer order number Anal. Output Anal. Input Digital Input/Output B TSX DEZ 12D2 TSX DEZ 08A4 TSX DEZ 12D2K TSX DEZ 08A5 TSX DEZ 32D2 TSX DSZ 04T22 TSX DSZ 08T2 TSX DSZ 08R5 TSX DSZ 08T2K TSX DSZ 32T2 TSX DSZ 32R5 TSX DMZ 28DT TSX DMZ 28DR TSX DMZ 28AR TSX DMZ 64DTK (*) TSX DMZ 28DTK TSX DMZ 16DTK TSX 37-22 (integrated) TSX AEZ 801 TSX AEZ 802 TSX AEZ 414 TSX 37-22 (integrated) TSX ASZ 401 TSX ASZ 200 Order No. 7789312xxx 7789307xxx 7789301xxx 7789307xxx 7789314xxx 7789312xxx 7789312xxx 7789308xxx 7789301xxx 7789314xxx 7789330xxx 7789313xxx 7789331xxx 7789331xxx 7789301xxx 7789301xxx 7789301xxx 7789257xxx 7789311xxx 7789311xxx 7789309xxx 7789257xxx 7789310xxx 7789310xxx Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 2 1 1 1 1 1 1 1 1 Type 12-channel - H 8-channel - R 12-channel - H 8-channel - R 32-channel - H 16-channel - R 32-channel - R 16-channel - H 16-channel - R 16-channel - R 32-channel - H 16-channel - H 16-channel - H - see page B.39 Qty B) B) A, B) D) D) B) D) D) A, B) B) 1 1 1 1 1 Type Analog input/output Digital relay output - see page B.42 Qty 16-channel B, E) 1 16-channel B, E) 1 16-channel B) 2 Type - see page B.54 Qty 8-channel 8-channel C) 8-channel 32-channel C) C) Type 1 1 1 1 1 2 2 1 1 1 A, C) 1 1 16-channel B) 1 12-channel C) 1 16-channel 16-channel B) 2 1 32-channel 12-channel A, C) 1 1 B) C) 9 channels M 8-channel 8-channel 4-channel 9 channels M 4-channel 4-channel Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 3 0 1 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) E) Four channels unused * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.8 Qty 1 1 1 1 1 1 1 PLC Interfaces H-, R- and S-System Selection Guide PLC Télémécanique - Premium PLC I/O cards Cables Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Anal. Output Anal. Input Digital output Digital input Manufacturer order number TSX DEY 08D2 TSX DEY 16D2 TSX DEY 16D3 TSX DEY 16A2 (1) TSX DEY 16A3 TSX DEY 16A4 TSX DEY 16A5 TSX DEY 16FK (*) TSX DEY 32D2K (*) TSX DEY 64D2K (*) TSX DSY 08T2 TSX DSY 08T22 TSX DSY 16T2 TSX DSY 08T31 TSX DSY 16T3 TSX DSY 08R5 TSX DSY 16R5 TSX DSY 08R5A TSX DSY 08R4D TSX DSY 08S5 TSX DSY 16S4 TSX DSY 32T2K (*) TSX DSY 64T2K (*) TSX AEY 414 TSX AEY 414 TSX AEY 420 TSX AEY 800 TSX AEY 810 TSX AEY 1600 TSX ASY 410 TSX ASY 410 TSX ASY 800 Order No. 7789322xxx 7789322xxx 7789322xxx 7789315xxx 7789315xxx 7789315xxx 7789315xxx 7789301xxx 7789301xxx 7789301xxx 7789322xxx 7789317xxx 7789322xxx 7789317xxx 7789322xxx 7789316xxx 7789316xxx 7789318xxx 7789318xxx 7789316xxx 7789316xxx 7789301xxx 7789301xxx 7789320xxx 7789319xxx 7789259xxx 7789259xxx 7789261xxx 7789259xxx 7789320xxx 7789321xxx 7789259xxx Qty 1 1 1 1 1 1 1 1 2 4 1 1 1 1 1 1 1 1 1 1 1 2 4 1 1 1 1 1 2 1 1 1 8-channel - H 16-channel - H 16-channel - H 16-channel - R 16-channel - R 16-channel - R 16-channel - R 16-channel - H 32-channel - H 32-channel - H - see page B.39 Qty Type B) B, G) D) B) A, B) A, B) 1 1 1 1 1 1 1 1 1 2 8-channel - R 1 8-channel - R 16-channel - H 16-channel - R 16-channel - R 16-channel - R 16-channel - R 16-channel - R 16-channel - R 1 1 1 1 1 1 1 1 G) D) D) D) D) Type 16-channel 16-channel 16-channel 16-channel 16-channel - see page B.42 Qty B) B) B) B) B) Analog input/output Digital relay output - see page B.54 Qty Type Qty Type 1 1 1 1 1 1 1 1 2 4 B 8-channel C) 1 16-channel C) 1 32-channel 32-channel A,C) 1 2 A,C) 1 1 1 1 1 2 1 1 1 4-channel 8-channel 8-channel P 8-channel P 8-channel P 8-channel P 4-channel 4-channel 8-channel P Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 3 0 1 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) G) Only use modules without LED 1) Use in ac mode * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.9 PLC Interfaces H-, R- and S-System Selection Guide PLC Télémécanique - Twido PLC I/O cards Cables Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Digital input Manufacturer order number Digital I/O Digital output B - see page B.39 - Qty Type Qty 8-channel - H 1 1 1 1 1 TWD DDI 8DT TWD DDI 16DT TWD DDI 16DK (1) TWD DDI 32DK (1) TWD DDO 8UT TWD DDO 8TT TWD DDO 16UK TWD DDO 16TK TWD DDO 32UK TWD DDO 32TK TWD DRA 8RT TWD DRA 16RT TWD LMDA 20DTK (1) TWD LMDA 20DUK (1) 7789100xxx 7789100xxx 7789328xxx 7789328xxx 7789100xxx 7789100xxx 7789328xxx 7789329xxx 7789328xxx 7789329xxx 7789108xxx 7789104xxx 7789327xxx 7789326xxx 1 1 1 2 1 1 1 1 2 2 1 1 1 1 TWD LMDA 20DTR TWD LMDA 40DUK (1) 7789100xxx 7789104xxx 7789327xxx 7789326xxx 1 1 2 2 TWD AMI 2HT TWD AMO 1HT TWD AMM 3HT TWD ALM 3LT 7789250xxx 7789250xxx 7789250xxx 7789250xxx 1 1 1 1 TWD LMDA 40DTK (1) Anal. I/O Order No. 16-channel - H 16-channel - H 32-channel - H 8-channel - H B) B) A, B) 16-channel - H 32-channel - H 8-channel - R 16-channel - R 12-channel - H 12-channel - H 8-channel - H 12-channel - H 16-channel - R 12-channel - H 12-channel - H 8-channel - H Type 16-channel 16-channel 16-channel - see page B.42 Qty B) B) B) Analog input/output Digital relay output - see page B.54 Qty Type Type 1 1 2 8-channel C) 1 16-channel C) 1 32-channel A,C) 1 8-channel C) 1 8-channel C) 2 1 A) D) B) B) B) D) B) 1 1 1 1 1 1 1 1 2 2 2 1 1 16-channel 16-channel B) 16-channel B) 1 16-channel B) 2 B) 4-channel 4-channel 4-channel 4-channel Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 1 0 0 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) 1) Use in positive logic * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.10 Qty 1 1 1 1 PLC Interfaces H-, R- and S-System Selection Guide PLC Télémécanique - Quantum PLC I/O cards Cables Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Anal. Output Anal. Input Dig. I/O Digital output Digital input Manufacturer order number 140 DAI 540 00 140 DAI 540 00 140 DAI 553 00 140 DAI 740 00 140 DAI 740 00 140 DAI 340 00 140 DAI 340 00 140 DAI 353 00 140 DAI 440 00 140 DAI 440 00 140 DAI 453 00 140 DDI 841 00 140 DDI 853 00 140 DDI 353 00 140 DDI 364 00 140 DAO 840 00 140 DAO 840 00 140 DAO 842 10 Order No. 140 DDO 353 00 140 DDO 843 00 140 DDO 364 00 140 DRA 840 00 140 DDM 390 00 7789118xxx 7789110xxx 7789118xxx 7789118xxx 7789110xxx 7789118xxx 7789110xxx 7789118xxx 7789118xxx 7789110xxx 7789118xxx 7789119xxx 7789121xxx 7789121xxx 7789301xxx 7789118xxx 7789112xxx 7789113xxx 7789121xxx 7789120xxx 7789301xxx 7789118xxx 7789133xxx 140 ACI 030 00 140 ACI 030 00 140 AVI 030 00 140 AVI 030 00 140 ARI 030 10 140 ACI 040 00 140 AII 330 00 140 ACO 020 00 140 ACO 130 00 140 AIO 330 00 7789125xxx 7789134xxx 7789125xxx 7789134xxx 7789135xxx 7789123xxx 7789136xxx 7789124xxx 7789126xxx 7789137xxx Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 1 1 1 1 1 6 1 1 32-channel - R 16-channel - R 32-channel - R 32-channel - R 16-channel - R 32-channel - R 16-channel - R 32-channel - R 32-channel - R 16-channel - R 32-channel - R 16-channel - H 32-channel - H 32-channel - H 32-channel - H 32-channel - R 16-channel - R 16-channel - R - see page B.39 Qty Type D) D) B) A, B) A, B) A, B) D) D) D) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 Type - see page B.42 Qty D) B) 1 1 - see page B.54 Qty Type Qty Type B 16-channel 16-channel 16-channel 16-channel B) B) B) B) 1 2 2 6 32-channel 16-channel 32-channel 32-channel - R 16-channel - H Analog input/output Digital relay output 16-channel B) 1 8-channel A, C) C, F) A, C) C) 1 1 3 1 8-channel 8-channel 8-channel 8-channel 8-channel 16-channel 8-channel 4-channel 8-channel 8-channel 1 1 1 1 1 1 1 1 1 1 Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 3 0 1 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil) * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.11 PLC Interfaces H-, R- and S-System Selection Guide PLC Télémécanique - M340 PLC I/O cards Cables Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Digital input Manufacturer order number Anal. I/O Anal. O Anal. Input Digital I/O Digital output B Order No. Qty BMX DDI 1602 BMX DDI 1603 BMX DDI 3202K BMX DDI 6402K BMX DAI 1602 (1) BMX DAI 1602 (2) BMX DAI 1603 BMX DAI 1604 BMX DAO 1605 BMX DDO 1602 BMX DDO 1612 BMX DDO 3202K BMX DDO 6402K BMX DRA 0805 BMX DRA 1605 BMX DDM 16025 7789380xxx 7789382xxx 7789387xxx 7789387xxx 7789630xxx 7789382xxx 7789382xxx 7789382xxx 7789383xxx 7789380xxx 7789380xxx 7789387xxx 7789387xxx 7789633xxx 7789384xxx 7789635xxx 1 1 1 2 1 1 1 1 1 1 1 1 2 1 1 1 BMX DDM 16022 BMX DDM 3202K BMX AMI 0410 (3) BMX AMI 0410 (4) BMX ART 0414 BMX ART 0814 BMX AMO 0210 7789386xxx 7789387xxx 7789637xxx 7789638xxx 7789639xxx 7789639xxx 7789640xxx 1 1 1 1 1 2 1 BMX AMM 0600 (3) BMX AMM 0600 (4) 7789628xxx 7789629xxx 1 1 16 channels-H 16 channels-R 32 channels-H 32 channels-H 16 channels-H 16 channels-R 16 channels-R 16 channels-R 16 channels-R - see page B.39 Qty Type (B) (A) (B) (A) (B) (B) (D) (K) 1 1 1 2 1 1 1 1 1 Type - see page B.42 Qty 16 channels-H (B) 1 16 channels-H 16 channels-H 16 channels-H (B) 2 4 1 (B) (B) (D) (D) (D) - see page B.54 Qty Type 16 channels 16 channels 16 channels 16 channels 16 channels-R 16 channels-R 8 channels-H 8 channels-R 8 channels-H 16 channels-H Analog input/output Digital relay output (C) (C) (C) (C) Type 1 1 2 4 1 1 1 1 2 2 4 channels 4 channels 16 channels 16 channels 4 channels 4 channels 4 channels Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 2 3 6 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) K) Each interface have one common * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com (1) use in 24 VDC, negative logic (2) use in 24 VAC (3) Use this cable for voltage signals. (4) Use this cable for current signals. B.12 Qty 1 1 1 2 1 1 1 PLC Interfaces H-, R- and S-System Selection Guide PLC Rockwell - SLC 500 PLC I/O cards Cables Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Anal. Anal. Anal. O I I/O Digital output Digital input Manufacturer order number 1746 - IB32 1746 - IV32 1746 - IB16 1746 - IC16 1746 - IN16 1746 - ITB16 1746 - ITV16 1746 - IV16 1746 - IB8 1746 - IV8 1746 - OB32 1746 - OV32 1746 - OB16 1746 - OB16E 1746 - OBP16 1746 - OG16 1746 - OV16 1746 - OVP16 1746 - OW16 1746 - OB8 1746 - OBP8 1746 - OV8 1746 - OW8 1746 - OX8 1746 - OW4 1746 - NI8 1746 - NI4 1746 - NO4V 1746 - NO4I 1746 - NIO4V 1746 - NIO4I Order No. 7789005xxx 7789670xxx 7789001xxx 7789001xxx 7789001xxx 7789001xxx 7789000xxx 7789000xxx 7789100xxx 7789100xxx 7789006xxx 7789006xxx 7789003xxx 7789003xxx 7789003xxx 7789003xxx 7789003xxx 7789003xxx 7789002xxx 7789100xxx 7789100xxx 7789100xxx 7789100xxx 7789100xxx 7789100xxx 7789011xxx 7789008xxx 7789010xxx 7789010xxx 7789009xxx 7789009xxx Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 32-channel - H 32-channel - H 16-channel - H 16-channel - H 16-channel - H 16-channel - H 16-channel - H 16-channel - H 8-channel - H 8-channel - H A, B) 32-channel - H A) A) 16-channel - H 16-channel - H 16-channel - H 1 1 1 1 1 1 1 1 1 1 Type 16-channel - see page B.42 Qty B) - see page B.54 Qty Type Type Qty 2 B 32-channel A, C) 1 16-channel 16-channel 16-channel C) 1 1 1 16-channel 8-channel 8-channel C, F) 8-channel C, F) 1 8-channel C, F) 1 1 C) C) 1 1 1 8-channel - H 16-channel - H - see page B.39 Qty Type Analog input/output Digital relay output C) C) 1 1 1 1 F) 1 8-channel 4-channel 4-channel 4-channel 4-channel 4-channel 1 1 1 1 1 1 Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 0 0 5 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil) * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.13 PLC Interfaces H-, R- and S-System Selection Guide PLC Rockwell - Compact Logix PLC I/O cards Cables Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Digital input Manufacturer order number Anal. Input Dig. I/O Digital output B Qty 1769 - IA8I 1769 - IM12 1769 - IA16 1769 - IQ16 1769 - IQ16F 1769 - IQ32 1769 - OA8 1769 - OB8 1769 - OW8 1769 - OW8I 1769 - OA16 1769 - OB16 1769 - OB16P 1769 - OV16 1769 - OW16 1769 - OB32 1769 - IQ6XOW4 7789016xxx 7789025xxx 7789025xxx 7789019xxx 7789019xxx 7789019xxx 7789017xxx 7789015xxx 7789017xxx 7789016xxx 7789024xxx 7789018xxx 7789018xxx 7789018xxx 7789024xxx 7789018xxx 7789014xxx 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 2 1 1769 - IF4 7789026xxx 7789046xxx 7789027xxx 7789047xxx 7789028xxx 7789045xxx 7789029xxx 7789043xxx 7789044xxx 7789044xxx 1 1 1 1 1 1 1 1 1 1 1769 - IF4I 1769 - IF8 Anal. Output Order No. 1769 - OF2 1769 - OF4CI 1769 - OF8V 1769 - OF8C Type - see page B.39 Qty 16-channel - R 16-channel - R 16-channel - R 16-channel - H 16-channel - H 16-channel - H 8-channel - R 1 1 1 1 1 2 1 8-channel - R 16-channel - R 16-channel - R 1 1 1 16-channel - H 16-channel - R 1 1 16-channel - R 1 Type Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 0 1 9 0 2 0 Notes concerning the use of interface modules: C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.14 Analog input/output Digital relay output - see page B.42 Qty - see page B.54 Qty Type 8-channel C) 1 16-channel 16-channel C) 1 1 16-channel C) C) Type Qty 2 4-channel 4-channel 4-channel 4-channel 8-channel 8-channel 4-channel 4-channel 8-channel 8-channel 1 1 1 1 1 1 1 1 1 1 PLC Interfaces H-, R- and S-System Selection Guide PLC Rockwell - Control Logix PLC I/O cards Cables Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Anal. O Anal. I Digital output Digital input Manufacturer order number 1756-IA16 1756-IA16I 1756-IA8D 1756 - IB16 1756-IB16D 1756-IB16I 1756-IB32 1756 - IC16 1756-IH16I 1756-IM16I 1756 - IN16 1756 - OA16 1756-OA16I 1756 - OA8 1756-OA8D 1756-OA8E 1756-OB16D 1756 - OB16E 1756-OB16I 1756 - OB32 1756 - OB8 1756-OB8EI 1756-OC8 1756-OH8I 1756-ON8 1756-OW16I 1756-OX8I 1756-IF6I 1756-IF6I 1756-IF16 1756 - IF8 1756 - IF8 1756-IR6I 1756-OF4 1756-OF4 1756-OF6VI 1756-OF6CI 1756-OF8 1756-OF8 1756-OV16E Order No. 7789031xxx 7789030xxx 7789048xxx 7789039xxx 7789049xxx 7789049xxx 7789041xxx 7789031xxx 7789030xxx 7789030xxx 7789031xxx 7789056xxx 7789030xxx 7789057xxx 7789048xxx 7789048xxx 7789040xxx 7789058xxx 7789059xxx 7789042xxx 7789151xxx 7789152xxx 7789153xxx 7789154xxx 7789057xxx 7789030xxx 7789155xxx 7789156xxx 7789157xxx 7789032xxx 7789035xxx 7789036xxx 7789158xxx 7789033xxx 7789034xxx 7789157xxx 7789159xxx 7789037xxx 7789038xxx 7789165xxx Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 16-channel - R 32-channel - R 8-channel - R 16-channel - H 16-channel - H 16-channel - H 32-channel - H 16-channel - R 32-channel - R 32-channel - R 16-channel - R 16-channel - R 32-channel - R 8-channel - R 8-channel - R 8-channel - R - see page B.39 Qty Type B) B) B) A, B) D) D) D) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Type 16-channel 16-channel 16-channel 16-channel - see page B.42 Qty B) B) B) B) D) D) - see page B.54 Qty Type Qty Type 1 1 1 2 B 16-channel 16-channel 16-channel 32-channel 8-channel 8-channel 16-channel - R 16-channel - R 8-channel - R 32-channel - R 16-channel - R Analog input/output Digital relay output C) C) C) A, C) C) C) 1 1 1 1 1 1 1 1 1 1 1 8-channel 8-channel 16-channel 8-channel 8-channel 8-channel 4-channel 4-channel 8-channel 8-channel 8-channel 8-channel 16-channel 1 1 1 1 1 1 1 1 1 1 1 1 1 Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 0 3 1 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.15 PLC Interfaces H-, R- and S-System Selection Guide PLC Fanuc 90-30 and Alspa 8035 Cables PLC I/O cards Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Digital input Manufacturer order number Anal Anal Anal. In. I/O . O put Digital output B IC693MDL230 IC693MDL231 IC693MDL240 IC693MDL241 IC693MDL630 IC693MDL632 IC693MDL634 IC693MDL640 IC693MDL643 IC693MDL645 IC693MDL646 IC693MDL654 IC693MDL655 IC693MDL310 IC693MDL340 IC693MDL730 IC693MDL731 IC693MDL732 IC693MDL733 IC693MDL740 IC693MDL741 IC693MDL742 IC693MDL752 IC693MDL753 IC693ALG220 IC693ALG221 IC693ALG222 IC693ALG223 IC693ALG390 IC693ALG391 IC693ALG442 Order No. 7789064xxx 7789064xxx 7789061xxx 7789067xxx 7789067xxx 7789634xxx 7789067xxx 7789067xxx 7789067xxx 7789067xxx 7789067xxx 7789066xxx 7789066xxx 7789063xxx 7789063xxx 7789069xxx 7789069xxx 7789068xxx 7789068xxx 7789068xxx 7789068xxx 7789068xxx 7789066xxx 7789066xxx 7789076xxx 7789075xxx 7789072xxx 7789072xxx 7789073xxx 7789073xxx 7789074xxx Qty 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 16-channel - R 16-channel - R 16-channel - R 16-channel - H 8-channel - H 8-channel - R 8-channel - H 16-channel - H 16-channel - H 16-channel - H 16-channel - H 32-channel - H 32-channel - H 16-channel - R 16-channel - R - see page B.39 Qty Type D) B, H) H) B) B) B, H) B, H) A, B, H) A, B, H) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8-channel - H 1 8-channel - H 1 16-channel - H 1 32-channel - H A) Type - see page B.42 Qty 16-channel B, H) 1 16-channel 16-channel 16-channel 16-channel 16-channel 16-channel B) 1 1 1 1 2 2 B) B, H) B, H) B, H) B, H) Analog input/output Digital relay output - see page B.54 Qty Type 8-channel C, F) 1 8-channel C, F) 1 16-channel C, F) 1 16-channel C, F) 1 32-channel A, C) 1 Type 1 4-channel 4-channel 8-channel 8-channel 8-channel 8-channel 16-channel Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 0 6 7 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil) H) Use the PLC I/O card in positive logic only * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.16 Qty 1 1 1 1 1 1 1 PLC Interfaces H-, R- and S-System Selection Guide PLC Fanuc RX3i PLC Cables I/O cards Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Anal. Output Anal. Input Digital output Digital input Manufacturer order number IC694MDL230 IC694MDL231 IC694MDL240 IC694MDL241 IC694MDL250 IC694MDL260 (1) IC694MDL632 (1) IC694MDL634 IC694MDL645 IC694MDL646 IC694MDL654 (1) IC694MDL655 (1) IC694MDL660 IC694MDL310 IC694MDL330 (1) IC694MDL340 IC694MDL350 IC694MDL390 IC694MDL732 IC694MDL734 IC694MDL740 (1) IC694MDL741 (1) IC694MDL742 (1) IC694MDL752 (1) IC694MDL753 (1) IC694MDL754 (1) IC694MDL930 IC694MDL931 IC694MDL940 (1) IC694ALG220 IC694ALG221 IC694ALG222 (2) IC694ALG223 IC695ALG600 (4) IC695ALG600 (5) (6) IC695ALG608 IC695ALG616 IC694ALG390 IC694ALG391 IC694ALG392 (6) IC694ALG392 (5) IC695ALG704 IC695ALG708 IC695ALG808 - see page B.39 - Qty Type Qty 7789064xxx 7789064xxx 7789061xxx 7789067xxx 7789631xxx 7789632xxx 7789634xxx 7789067xxx 7789067xxx 7789067xxx 7789066xxx 7789066xxx 7789619xxx 7789063xxx 7789634xxx 7789063xxx 7789631xxx 7789636xxx 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 1 16-channel - R D) 16-channel - R D) 16-channel - R D) 16-channel - H B, H) 32-channel - R D) 32-channel - R D) 8-channel - R D) 8-channel - H H) 16-channel - H B, H) 16-channel - H B, H) 32-channel - H B, H) 32-channel - H B, H) 32-channel - H B, H) 16-channel - R D) 8-channel - R D) 16-channel - R D) 32-channel - R D) 16-channel - R D) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7789068xxx 7789669xxx 7789068xxx 7789068xxx 7789068xxx 7789066xxx 7789066xxx 7789618xxx 7789064xxx 7789665xxx 7789666xxx 7789076xxx 7789075xxx 7789072xxx 7789072xxx 7789622xxx 7789623xxx 7789667xxx 7789626xxx 7789073xxx 7789073xxx 7789620xxx 7789624xxx 7789668xxx 7789625xxx 7789621xxx 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 16-channel - R D) 1 16-channel - H 1 32-channel - H A) 1 Order No. 16-channel - R D) 32-channel - R D) 16-channel - R D) Analog input/output Digital relay output - see page B.42 - Type Qty 16-channel B, H) 1 Type - see page B.54 Qty Qty Type B 16-channel B, H) 16-channel B, H) 16-channel B, H) 16-channel B, H) 16-channel B, H) 1 1 2 2 2 8-channel C, F) 1 16-channel C, F) 1 16-channel C, F) 1 32-channel - H A, C) 32-channel - H A, C) 1 1 1 1 1 4-channel 4-channel 8-channel 8-channel 16-channel 16-channel 8-channel 16-channel 8-channel 8-channel 4-channel 4-channel 4-channel 8-channel 8-channel 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 0 6 7 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil) H) Use the PLC I/O card in positive logic only K) Each interface have one common (1) All the groups with same common (2) Single Ended mode applications (3) Differential Ended applications (4) RTD or resistance applications (5) Voltage applications (6) Current applications B.17 PLC Interfaces H-, R- and S-System Selection Guide PLC OMRON CQM1 PLC I/O cards Cables Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Digital input Manufacturer order number Anal. O Anal. I Digital output B Order No. Qty ID211 ID212 ID213 IA121 IA221 OC221 OC222 OD211 OD212 OD213 OD214 OA221 AD041 7789646xxx 7789647xxx 7789370xxx 7789652xxx 7789652xxx 7789653xxx 7789654xxx 7789653xxx 7789655xxx 7789372xxx 7789655xxx 7789656xxx 7789252xxx 1 1 1 1 1 1 1 1 1 1 1 1 1 DA021 7789251xxx 1 Type - see page B.39 Qty 16-channel - H 16-channel - H B), H) 32-channel - H B, H) 8-channel - R 8-channel - R 8-channel - R 16-channel - R 8-channel - H 16-channel - H 1 1 1 1 1 1 1 1 1 Type 16-channel 16-channel - see page B.42 Qty B, H) B, H) 1 1 1 1 - see page B.54 Qty Type Qty Type 1 2 32-channel 16-channel 8-channel - R Analog input/output Digital relay output A, C) C) 1 1 8-channel J) 1 4-channel J) 1 Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 1 4 3 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) H) Only for positive logic, for negative logic invert the polarity of the source on the interface. J) The PLC connector is not included. The wires of the cable are free and equipped with ferrules. * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.18 PLC Interfaces H-, R- and S-System Selection Guide PLC OMRON C200H PLC I/O cards Cables Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Digital output Digital input Manufacturer order number ID211 ID001 ID002 IA121 IA122 IM211 ID212 IA122-V IA222-V IM212 ID216 ID217 OC221 OC224-V OC223 OD214 OD411 OD213 OA221 OC222-V OD217 OD211 OA222-V OC225 OD212 Order No. 7789100xxx 7789100xxx 7789100xxx 7789108xxx 7789104xxx 7789108xxx 7789100xxx 7789104xxx 7789104xxx 7789100xxx 7789370xxx 7789370xxx 7789108xxx 7789104xxx 7789108xxx 7789100xxx 7789100xxx 7789100xxx 7789108xxx 7789104xxx 7789100xxx 7789100xxx 7789104xxx 7789104xxx 7789100xxx Qty 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 Type 8-channel - H J) 8-channel - H J) 8-channel - H J) 8-channel - R J) 16-channel - R J) 8-channel - H J) 16-channel - H B, J) 16-channel - R J) 16-channel - R J) 16-channel - H B, J) 32-channel - H A, B, H) 32-channel - H A, B, H) 8-channel - R J) 16-channel - R J) 8-channel - R J) 8-channel - H J) 8-channel - H J) 8-channel - R J) 16-channel - R J) 12-channel - H J) 16-channel - R J) 16-channel - R J) 16-channel - H J) - see page B.39 Qty 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 1 1 1 Type Analog input/output Digital relay output - see page B.42 Qty - see page B.54 Qty Type Qty Type B 16-channel B, J) 1 16-channel 16-channel 16-channel B, J) 1 2 4 B) B) 8-channel C, J) 1 12-channel C, J) 1 Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 1 4 2 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) H) Only for positive logic, for negative logic invert the polarity of the source on the interface. J) The PLC connector is not included. The wires of the cable are free and equipped with forks. * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.19 PLC Interfaces H-, R- and S-System Selection Guide PLC OMRON CJ1W PLC I/O cards Cables Interfaces Digital direct input/output Standard Digital optodecoupled input - see page B.21 - Digital input Manufacturer order number Digital output B ID211 ID231 ID232 ID261 ID262 IA111 IA201 OC201 OC211 OD201 OD202 OD211 OD212 OD231 OD232 OD233 OD261 OD263 OA201 Order No. 7789645xxx 7789370xxx 7789371xxx 7789370xxx 7789371xxx 7789664xxx 7789648xxx 7789649xxx 7789664xxx 7789650xxx 7789650xxx 7789651xxx 7789651xxx 7789372xxx 7789373xxx 7789373xxx 7789372xxx 7789373xxx 7789648xxx Qty 1 1 1 2 2 1 1 1 1 1 1 1 1 1 1 1 2 2 1 Type - see page B.39 Qty 16-channel - H B, H) 32-channel - H A, B, H) 32-channel - H A, B, H) 32-channel - H A, B, H) 32-channel - H A, B, H) 16-channel - R 8-channel - R 16-channel - R 16-channel - R 8-channel - H 1 1 1 2 2 1 1 1 1 1 Type 16-channel 16-channel 16-channel 16-channel 16-channel - see page B.42 Qty B) B) B) B) B) - see page B.54 Qty Type Type 1 2 2 4 4 8-channel 16-channel 16-channel 32-channel 32-channel 32-channel - H A) 32-channel - H A) 32-channel - H A) 8-channel - R Analog input/output Digital relay output C) C) C) A, C) A, C) 1 1 1 1 1 1 2 2 1 Notes concerning cable lengths: The suffix xxx of the “Order number” shows the length of the cable in dm. The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050) Example: Cable 2 meters in length: Order number: 7 7 8 9 1 0 0 0 2 0 Notes concerning the use of interface modules: A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used: - 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V) H) Only for positive logic, for negative logic invert the polarity of the source on the interface. * All I/O signals with same common. * Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com B.20 Qty Type No. of channels 8 channels 12 chan. Functionalities Compact version Connection H or R System Type of wiring H System 2-wire V R System 2-wire V H System 2-wire V C C Screw V V 1-wire C C H System 2-wire 16 channels 3-wire C C C V V V V V V V V V 1-wire R System V V V 2-wire 3-wire C C V V 1-wire C V V H System 2-wire 32 channels 3-wire 1-wire R System 2-wire 3-wire C C C V V V V V V V V V Tension c. 1 LED per chan. Modules Disconnectable Fuse L Z Z Z L L L L L L L I I I L L I Z Z Z F L L L L L L L I I I L L Note: Preferred articles in bold I I F B.22 B.22 9445630000 RS 12ES-D-L H/V B.23 9445700000 RS 16ES H/V B.24 9445710000 RS 16ES-L H/V B.24 9447700000 (*) RS 16ES H/Z B.24 9447710000 RS 16ES-L H/Z B.24 9445810000 RS 16ES-S-I-L H/V B.24 9445720000 RS 16ES-D H/V B.25 9445730000 RS 16ES-D-L H/V B.25 9447730000 RS 16ES-D-L H/Z B.25 9445750000 RS 16ES-D-I-L H/V B.25 RS 16ES-D-I-L H/Z B.25 9445820000 RS 16ES-D-F H/V B.26 9445760000 RS 16ES-T H/V B.26 9445770000 RS 16ES-T-L H/V B.26 9447770000 RS 16ES-T-L H/Z B.26 9441500000 RS16ES RSV1,6/V B.27 9441860000 RS16ES-I RSV1,6/V B.27 9441700000 RS16ES-DP RSV1,6/V B.28 9441560000 RS16ES-DP/F RSV1,6/V B.28 (*) 9441600000 (*) RS16E-3E/I RSV1,6/V B.29 9445900000 RS 32ES H/V B.30 9445910000 RS 32ES-L H/V B.30 9447900000 (*) RS 32ES H/Z B.30 9447910000 RS 32ES-L H/Z B.30 9445870000 RS 32ES-S-I-L H/V B.31 9445930000 RS 32ES-D-L H/V B.32 9447930000 RS 32ES-D-L H/Z B.32 9445950000 RS 32ES-D-I-L H/V B.33 9447950000 F RS 8ES-D-L H/V Page 9441540000 (*) RS8ES-DP RSV1,6/V 9447750000 F I Z Z Type 9445530000 L Z Z Order No. RS 32ES-D-I-L H/Z B.33 9445980000 RS 32ES-D-F H/V B.34 9445960000 RS 32ES-T H/V B.35 9445970000 RS 32ES-T-L H/V B.35 9447970000 RS 32ES-T-L H/Z B.35 9441510000 RS32ES RSV1,6/V B.36 9441870000 RS32ES-I RSV1,6/V B.36 9441710000 RS32ES-DP RSV1,6/V B.37 9441570000 9441610000 (*) (*) RS32ES-DP/F RSV1,6/V B.37 RS32E-3E/I RSV1,6/V B.38 (*) Available upon customer request B.21 PLC Interfaces H-, R- and S-System Module Overview - Direct Inputs/Outputs for Digital Cards B RS ES-D - 8-channel RS ES-DP - 8-channel H-System – 2-wire (common + or –) Version: screw connection R-System – 2-wire (common + or –) Version: screw connection Dimensions B 0.0 1 0.1 2 0.2 3 0.3 4 0.7 8 C I/O PCB Connector C C C A - - C + C + Connector HE10/20 poles C Shunt B For 8-channel digital I/O cards H System and R System Supply Voltage PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards 18 20 FUS +F 17 19 Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C mm Note HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) RSV 1.6 connector – 12 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 24 V DC ± 10% 1 A (*) 3A – – Green + or – selectable with a jumper 3A 24 V DC / LED yellow 2A 3.15 A 250 V max 1 A (*) 3A – – – + or – selectable with a jumper 3A max 250 V 2A 3.15 A < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC 250 V AC III 2 1.7 KV DC -25…50 ºC -40…60 ºC 74 x 87.5 x 72 68 x 87.5 x 72 (*) Observe the max. permissible current for the common wires (*) Observe the max. permissible current for the common wires (**) No main-circuits Type Order No. Type RS8ES-DP RSV1,6/V RS 8ES-D-L H/V 9445530000 Ordering data Screw connection without LED Screw connection with LED Tension clamp connection without LED Tension clamp connection with LED Note B.22 (1) Available upon customer request Order No. 9441540000 (1) For 12-channel digital I/O cards System H PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards RS ES-D - 12-channel H-System – 2-wire (common + or –) Version: screw connection B Dimensions B 0.0 1 0.1 2 C C 0.2 3 0.3 4 1.3 12 - 18 20 C A Shunt Supply Voltage C C + C + FUS +F Connector HE10/20 poles I/O PCB Connector C 17 19 Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 24 V DC ± 10% 1 A (*) 3A – – Green + or – selectable with a jumper 3A 24 V DC / LED yellow 2A 3.15 A Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC mm Note 95 x 87.5 x 72 (*) Observe the max. permissible current for the common wires Ordering data Screw connection without LED Screw connection with LED Tension clamp connection without LED Tension clamp connection with LED Type Order No. RS 12ES-D-L H/V 9445630000 Note B.23 RS ES-S - 16-channel RS ES-S-I - 16 disconnectable channels C Dimensions B Disconnectable connector 1 0.0 1 0.0 2 0.1 + 18 20 17 19 FUS +F I/O PCB Connector 3 0.2 4 0.3 1.7 16 - 18 20 + FUS +F Connector HE10/20 poles 16 Connector HE10/20 poles 4 0.3 1.7 A 2 0.1 3 0.2 Supply Voltage C I/O PCB Connector B For 16-channel digital I/O cards System H Supply Voltage PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards 17 19 Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C mm Note HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14) HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) ≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED) 1 A (*) 3A – – Green (versions with LED) – – 24 V DC / LED yellow 2A 3.15 A 24 V DC ± 10% 1 A (*) 3A – Yes - each channel Green – – 24 V DC / LED yellow 2A 3.15 A < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC 81 x 87.5 x 72 110 x 87.5 x72 (*) Observe the max. permissible current for the common wires (*) Observe the max. permissible current for the common wires Type RS 16ES H/V C RS 16ES-L H/V C RS 16ES H/Z RS 16ES-L H/Z Type RS 16ES-S-I-L H/V Ordering data Screw connection without LED Screw connection with LED Tension clamp connection without LED Tension clamp connection with LED Note C : compact version (1) Available upon customer request B.24 C C Order No. 9445700000 9445710000 9447700000 (1) 9447710000 Order No. 9445810000 For 16-channel digital I/O cards System H RS ES-D - 16-channel RS ES-D-I - 16 disconnectable channels H-System – 2-wire (common + or –) Versions: screw / tension clamp connection - compact H-System – 2-wire (common + or –) Versions: screw / tension clamp connection - compact C C B Dimensions B Disconnectable connector 0.1 2 C 0.2 3 C 0.3 4 - + C + 18 20 17 19 FUS +F 1 0.1 2 0.2 3 0.3 4 1.7 16 - 18 20 C Supply Voltage Shunt Supply Voltage A C 0.0 C Shunt 16 1.7 C Connector HE10/20 poles C I/O PCB Connector C I/O PCB Connector C C + C + Connector HE10/20 poles 0.0 1 C 17 19 FUS +F Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C mm Note HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14) HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14) ≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED) 1 A (*) 3A – – Green (versions with LED) + or – selectable with a jumper 3A 24 V DC / LED yellow 2A 3.15 A 24 V DC ± 10% 1 A (*) 3A – Yes - each channel Green + or – selectable with a jumper 3A 24 V DC / LED yellow 2A 3.15 A < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC 117 x 87.5 x 72 119 x 87.5 x 72 (*) Observe the max. permissible current for the common wires (*) Observe the max. permissible current for the common wires Type RS 16ES-D H/V C RS 16ES-D-L H/V C Order No. 9445720000 9445730000 Type 9447730000 RS 16ES-D-I-L H/Z Ordering data Screw connection without LED Screw connection with LED Tension clamp connection without LED Tension clamp connection with LED Note PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards RS 16ES-D-L H/Z C : compact version C C RS 16ES-D-I-L H/V C Order No. C 9445750000 9447750000 (1) C : compact version (1) Available upon customer request B.25 RS ES-D-F - 16-channel with fuse RS ES-T - 16-channel H-System – 2-wire (common + or –) Version: screw connection H System – 3-wire (common + and –) Versions: screw / tension clamp connection - compact C Dimensions B 0.0 FUS 1 0.1 FUS 2 0.2 FUS 3 - 1.7 FUS 16 - - C + C + 18 20 FUS +F 17 19 I/O PCB Connector 4 0.1 2 0.2 3 0.3 4 1.7 16 + + + Supply Voltage FUS Connector HE10/20 poles 0.3 C A - C C 1 - Connector HE10/20 poles I/O PCB Connector C 0.0 + C Shunt B For 16-channel digital I/O cards System H Supply Voltage PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards 18 20 + + 17 19 FUS +F +F Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C mm Note HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26) ≤ 25V AC 50 V DC 1 A (*) 3A 0.5 A fuse on each channel – – + or – selectable with a jumper 3A 24 V DC / LED yellow 2A 3.15 A ≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED) 1 A (*) 3A – – Green (versions with LED) + and – 3A 24 V DC / LED yellow 2A 3.15 A < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC 122 x 87.5 x 72 110 x 87.5 x72 (*) Observe the max. permissible current for the common wires (*) Observe the max. permissible current for the common wires Type RS 16ES-D-F H/V Type RS 16ES-T H/V RS 16ES-T-L H/V Ordering data Screw connection without LED Screw connection with LED Tension clamp connection without LED Tension clamp connection with LED Note B.26 Order No. 9445820000 RS 16ES-T-L H/Z C : compact version C C Order No. 9445760000 9445770000 9447770000 For 16-channel digital I/O cards System R RS ES - 16-channel RS ES-I – 16 disconnectable channels System R – 1-wire cabling Version: screw connection System R – 1-wire cabling Version: screw connection B Dimensions Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards mm Note RSV 1.6 connector - 24 pole 0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16) RSV 1.6 connector - 24 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) max 150 V UC 1 A (*) 3A – – – – – max 150 V 2A – 250 V max 1 A (*) 3A – Yes - each channel – – – max 250 V 2A 3.15 A < 150 V AC III 2 1.1 KV DC -25…50 ºC -40…60 ºC 250 V AC III 2 1.7 KV DC -25…50 ºC -40…60 ºC 97 x 87.5 x 68 127 x 87.5 x 72 (*) Observe the max. permissible current for the common wires (**) No main-circuits (*) Observe the max. permissible current for the common wires (**) No main-circuits Type RS16ES RSV1,6/V Type RS16ES-I RSV1,6/V Ordering data Screw connection without LED Screw connection with LED Order No. 9441500000 Order No. 9441860000 Note B.27 PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards B For 16-channel digital I/O cards System R RS ES-DP - 16-channel RS ES-DP/F - 16-channel with fuse R-System – 2-wire (common + or –) Version: screw connection R-System – 2-wire (common + or –) Version: screw connection RSV 1.6 connector - 24 pole 0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16) RSV 1.6 connector - 24 pole 0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16) max 150 V UC 1 A (*) 3A – – – + or – selectable with a jumper 3A max 150 V UC 2A 3.15 A max 150 V UC 1 A (*) 3A 1 A fuse on each channel – – + or – selectable with a jumper 3A max 150 V UC 2A 3.15 A < 150 V AC III 2 1.1 KV DC -25…50 ºC -40…60 ºC < 150 V AC III 2 1.1 KV DC -25…50 ºC -40…60 ºC 123 x 87.5 x 72 123 x 109 x 72 (*) Observe the max. permissible current for the common wires (**) No main-circuits (*) Observe the max. permissible current for the common wires (**) No main-circuits Type RS16ES-DP RSV1,6/V Type RS16ES-DP/F RSV1,6/V Dimensions Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C mm Note Ordering data Screw connection without LED Screw connection with LED Note B.28 Order No. 9441700000 Order No. 9441560000 For 16-channel digital I/O cards System R PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards RS ES-3 E/I - 16 disconnectable channels R System – 3-wire (common + and –) Version: screw connection B Dimensions Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse RSV 1.6 connector - 24 pole 0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16) max 150 V UC 1 A (*) 3A – Yes - each channel – + and – 3A max 150 V UC 3.15 A Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C < 150 V AC III 2 1.1 KV DC -25…50 ºC -40…60 ºC mm Note 116 x 109 x 84 (*) Observe the max. permissible current for the common wires (**) No main-circuits Ordering data Screw connection without LED Screw connection with LED Note Type RS16E-3E/I RSV1,6/V Order No. 9441600000 (1) (1) Available upon customer request B.29 RS ES-S - 32-channel RS ES-S - 32-channel H System – 1-wire Version: screw connection - compact H System – 1-wire Version: tension clamp C - 18 20 + 17 19 FUS +F 1 2.1 2 3.7 16 18 20 17 19 0.0 1 0.1 2 1.7 16 - 18 20 + FUS +F 17 19 2.0 1 2.1 2 3.7 16 + 18 20 FUS +F Connector (2) HE10/20 poles 2.0 Supply Voltage 1 16 I/O PCB Connector 1.7 Supply Voltage 2 I/O PCB Connector 0.1 2 Connector (2) HE10/20 poles A 1 Connector (1) HE10/20 poles C 0.0 Connector (1) HE10/20 poles B I/O PCB Connector Dimensions Supply Voltage B For 32-channel digital I/O cards System H I/O PCB Connector PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards 17 19 Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C Length A x width B x height C C version mm mm Note 2 x HE 10 connectors - 20 pole 2 x HE 10 connectors - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26) – 24 V DC / LED yellow 2A 3.15 A ≤ 25V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED) 1 A (*) 3A – – Green (version with LED) – – 2 x 24 V DC / LED yellow (for each 16-channel block) 2A 3.15 A < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC ≤ 25V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED) 1 A (*) 3A – – Green (version with LED) – 90 x 87.5 x 72 145 x 87.5 x 72 (*) Observe the max. permissible current for the common wires (*) Observe the max. permissible current for the common wires Type RS 32ES H/V RS 32ES-L H/V Type Order No. RS 32ES H/Z RS 32ES-L H/Z 9447900000 (1) 9447910000 Ordering data Screw connection without LED Screw connection with LED Tension clamp connection without LED Tension clamp connection with LED Note B.30 C : compact version C C Order No. 9445900000 9445910000 (1) Available upon customer request For 32-channel digital I/O cards System H PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards RS ES-S-I - 32 disconnectable channels H System – 1-wire Version: screw connecion B Dimensions 1 B Supply Voltage 2 A Disconnectable connector 16 1.7 - 18 20 + 17 19 FUS +F 2.0 1 2.1 2 3.7 16 + 18 20 FUS +F 17 19 Connector (2) HE10/20 poles I/O PCB Connector Supply Voltage 1 C 2 0.1 Connector (1) HE10/20 poles I/O PCB Connector 0.0 Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse 2 x HE 10 connectors - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 24 V DC ± 10% 1 A (*) 3A – Yes - each channel Green – – 24 V DC / LED yellow 2A 3.15 A Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC mm Note 220 x 87.5 x 72 (*) Observe the max. permissible current for the common wires Ordering data Screw connection without LED Screw connection with LED Tension clamp connection without LED Tension clamp connection with LED Type Order No. RS 32ES-S-I-L H/V 9445870000 Note B.31 RS ES-D - 32-channel RS ES-D - 32-channel H-System – 2-wire (common + or –) Version: screw connection - compact H-System – 2-wire (common + or –) Version: tension clamp C 18 20 Shunt C + C + 17 19 FUS +F 2.1 2 3.7 16 C A C C 18 20 17 19 1.7 16 - 18 20 C + C + 17 19 FUS +F 2.0 1 2.1 2 3.7 16 C C C - - C + C + 18 20 17 19 FUS +F Connector (2) HE10/20 poles 1 Connector (2) HE10/20 poles 2.0 Shunt - - 2 C Supply Voltage 1 16 I/O PCB Connector 1.7 C 1 C Shunt 2 Supply Voltage 2 I/O PCB Connector C 0.1 C 0.0 0.1 C Connector (1) HE10/20 poles 1 0.0 C Connector (1) HE10/20 poles B I/O PCB Connector Dimensions Supply Voltage B For 32-channel digital I/O cards System H I/O PCB Connector PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C Length A x width B x height C C version mm mm Note 2 x HE 10 connectors - 20 pole 2 x HE 10 connectors - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26) 3A 24 V DC / LED yellow 2A 3.15 A 24 V DC ± 10% 1 A (*) 3A – – Green + or – selectable with a jumper 3A 2 x 24 V DC / LED yellow (for each 16-channel block) 2A 3.15 A < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC 24 V DC ± 10% 1 A (*) 3A – – Green + or – selectable with a jumper 170 x 87.5 x 72 230 x 87.5 x 72 (*) Observe the max. permissible current for the common wires (*) Observe the max. permissible current for the common wires Type Type Order No. RS 32ES-D-L D/Z 9447930000 Ordering data Screw connection without LED Screw connection with LED Tension clamp connection without LED Tension clamp connection with LED Note B.32 RS 32ES-D-L H/V C : compact version Order No. C 9445930000 For 32-channel digital I/O cards System H RS ES-D-I - 32 disconnectable channels RS ES-D-I - 32 disconnectable channels H-System – 2-wire (common + or –) Version: screw connection - compact H-System – 2-wire (common + or –) Version: tension clamp C Dimensions B Disconnectable connector - 18 20 Shunt C + C + 17 19 FUS +F 1 2.1 2 I/O PCB Connector A C 16 3.7 C 18 20 17 19 Connector (2) HE10/20 poles 2.0 C I/O PCB Connector 16 1.7 - - 18 20 + 17 19 C + C FUS +F 2.0 1 2.1 2 3.7 16 C C C - - C + C + 18 20 17 19 FUS +F Connector (2) HE10/20 poles Supply Voltage - Disconnectable connector Shunt 16 2 C Supply Voltage 1 1.7 C 0.1 C I/O PCB Connector 2 1 C Shunt 0.1 C Supply Voltage 2 I/O PCB Connector 1 Connector (1) HE10/20 poles 0.0 C 0.0 Connector (1) HE10/20 poles B C Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C Length A x width B x height C C version mm mm Note 2 x HE 10 connectors - 20 pole 2 x HE 10 connectors - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26) 3A 24 V DC / LED yellow 2A 3.15 A 24 V DC ± 10% 1 A (*) 3A – Yes - each channel Green + or – selectable with a jumper 3A 24 V DC / LED yellow 2A 3.15 A < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC 24 V DC ± 10% 1 A (*) 3A – Yes - each channel Green + or – selectable with a jumper 170 x 87.5 x 72 230 x 87.5 x 72 (*) Observe the max. permissible current for the common wires (*) Observe the max. permissible current for the common wires Type Type Order No. RS 32ES-D-I-L H/Z 9447950000 (1) Ordering data Screw connection without LED Screw connection with LED Tension clamp connection without LED Tension clamp connection with LED Note RS 32ES-D-I-L H/V C : compact version Order No. C PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards 9445950000 (1) Available upon customer request B.33 RS ES-D-F - 32-channel with fuse H-System – 2-wire (common + or –) Version: screw connection Dimensions I/O PCB Connector C 0.0 FUS 1 0.1 FUS 2 1.7 FUS 16 C C Shunt - 18 20 + 17 19 C C FUS +F 2.0 FUS 1 2.1 FUS 2 3.7 FUS 16 C C C - - C + C + 18 20 17 19 FUS +F Connector (2) HE10/20 poles A + I/O PCB Connector Supply Voltage 1 C Connector (1) HE10/20 poles B Shunt B For 32-channel digital I/O cards System H Supply Voltage 2 PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse 2 x HE 10 connectors - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) ≤ 25 V AC 50 V DC 1 A (*) 3A 0.5 A fuse on each channel – – + or – selectable with a jumper 3A 24 V DC / LED yellow 2A 3.15 A Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC mm Note 248 x 87.5 x 72 (*) Observe the max. permissible current for the common wires Ordering data Screw connection without LED Screw connection with LED Tension clamp connection without LED Tension clamp connection with LED Note B.34 Type RS 32ES-D-F H/V Order No. 9445980000 For 32-channel digital I/O cards System H RS ES-T - 32-channel RS ES-T - 32-channel H System – 3-wire (common + and –) Version: screw connection - compact H System – 3-wire (common + and –) Version: tension clamp PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards C B Dimensions 2 1.7 16 - Supply Voltage + - 18 20 + + 17 19 FUS +F +F 1 2.1 2 I/O PCB Connector + 3.7 16 + 18 20 17 19 1 0.1 2 1.7 16 + - 18 20 + + 17 19 FUS +F +F 2.0 1 2.1 2 3.7 16 + + + - 18 20 + + 17 19 FUS +F +F Connector (2) HE10/20 poles A - + - 2.0 + Connector (2) HE10/20 poles - - - I/O PCB Connector + Supply Voltage 1 1 Supply Voltage 2 C 0.0 0.1 + - Connector (1) HE10/20 poles I/O PCB Connector - 0.0 + Connector (1) HE10/20 poles B I/O PCB Connector - Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C Length A x width B x height C C version mm mm Note 2 x HE 10 connectors - 20 pole 2 x HE 10 connectors - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26) 3A 24 V DC / LED yellow 2A 3.15 A 24 V DC ± 10% 1 A (*) 3A – – Green + and – 3A 2 x 24 V DC / LED yellow (for each 16-channel block) 2A 3.15 A < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC ≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED) 1 A (*) 3A – – Green (versions with LED) + and – 176 x 87.5 x 72 221 x 87.5 x 72 (*) Observe the max. permissible current for the common wires (*) Observe the max. permissible current for the common wires Type RS 32ES-T H/V RS 32ES-T-L H/V Type Order No. RS 16ES-T-L H/Z 9447970000 Ordering data Screw connection without LED Screw connection with LED Tension clamp connection without LED Tension clamp connection with LED Note C C Order No. 9445960000 9445970000 C : compact version B.35 PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards B For 32-channel digital I/O cards System R RS ES - 32-channel RS ES-I – 32 disconnectable channels System R – 1-wire cabling Version: screw connection System R – 1-wire cabling Version: screw connection RSV 1.6 connector - 36 pole 0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16) RSV 1.6 connector - 36 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) max 150 V UC 1 A (*) 3A – – – – – max 150 V UC 2A – 250 V max 1 A (*) 3A – Yes - each channel – – – max 250 V 2A 3.15 A < 150 V AC III 2 1.1 KV DC -25…50 ºC -40…60 ºC 250 V AC III 2 1.7 KV DC -25…50 ºC -40…60 ºC 148 x 87.5 x 72 188 x 87.5 x 72 (*) Observe the max. permissible current for the common wires (**) No main-circuits (*) Observe the max. permissible current for the common wires (**) No main-circuits Type RS32ES RSV1,6/V Type RS32ES-I RSV1,6/V Dimensions Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C mm Note Ordering data Screw connection without LED Screw connection with LED Note B.36 Order No. 9441510000 Order No. 9441870000 For 32-channel digital I/O cards System R RS ES-DP - 32-channel RS ES-DP/F - 32-channel with fuse R-System – 2-wire (common + or –) Version: screw connection R-System – 2-wire (common + or –) Version: screw connection B Dimensions Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C mm Note RSV 1.6 connector - 36 pole 0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16) RSV 1.6 connector - 36 pole 0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16) max 150 V UC 1 A (*) 3A – – – + or – selectable with a jumper 3A max 150 V UC 2A 3.15 A max 150 V UC 1 A (*) 3A 1 A fuse on each channel – – + or – selectable with a jumper 3A max 150 V UC 2A 3.15 A < 150 V AC III 2 1.1 KV DC -25…50 ºC -40…60 ºC < 150 V AC III 2 1.1 KV DC -25…50 ºC -40…60 ºC 200 x 87.5 x 72 200 x 109 x 84 (*) Observe the max. permissible current for the common wires (**) No main-circuits (*) Observe the max. permissible current for the common wires (**) No main-circuits Type RS32ES-DP RSV1,6/V Type RS32ES-DP/F RSV1,6/V Ordering data Screw connection without LED Screw connection with LED Note PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards Order No. 9441710000 Order No. 9441570000 (1) (1) Available upon customer request B.37 PLC Interfaces H-, R- and S-System Direct Inputs/Outputs for Digital Cards B For 32-channel digital I/O cards System R RS ES-3 E/I - 32 disconnectable channels R System – 3-wire (common + and –) Version: screw connection Dimensions Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Operating voltage Max. current per channel Max. total current Fuse per channel Disconnection per channel LED status indication per channel Polarity distribution Max. current of joint potential PLC card supply voltage / LED voltage status PLC card supply current PLC card supply current fuse RSV 1.6 connector - 36 pole 0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16) max 150 V UC 1 A (*) 3A – Yes - each channel – + and – 3A max 150 V UC 2A 3.15 A Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C < 150 V AC III 2 1.1 KV DC -25…50 ºC -40…60 ºC mm Note 188 x 109 x 84 (*) Observe the max. permissible current for the common wires (**) No main-circuits Ordering data Screw connection without LED Screw connection with LED Note B.38 Type RS32E-3E/I RSV1,6/V Order No. 9441610000 Type No. of channels 16 channels H or R System H System Functionalities Type of wiring 2-wire Connection Compact version Screw C C C V V V Tension c. Modules 1 LED per chan. Pluggable optocoupler L L L O O O Note: Preferred articles in bold Order No. Type 9446900000 9446910000 (*) Page RS16E-OD 24-48V H/V B.40 RS16E-OD 115 H/V B.41 9446920000 (*) RS16E-OD 230V H/V PLC Interfaces H-, R- and S-System Module Overview – Opto-Decoupled Inputs/Outputs for Digital Cards B.41 (*) Available upon customer request B B.39 PLC Interfaces H-, R- and S-System Opto-Decoupled Inputs for Digital Cards For 16-channel digital cards RSE OD – 16-channel Dimensions System H – Pluggable optocouplers Version: screw connection C B C B A Technical data HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) C1 Connector HE10/20 poles 24…48 V UC 9…21 mA AC 7…16 mA DC 20 V AC 19 V DC 100 mA / 48 V– 24 up to 48 V DC 100 mA 1A 2A C2 FUS E1 R Input PCB Connector C1F < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC 1 E8 R C1F 8 C3 C4 FUS Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Operating Voltage Input current AC Input current DC Switching voltage AC Switching voltage DC Max. switching current/voltage Optocoupler polarisation voltage Continuous current per optocoupler Fuse (optocoupler power supply) I/O card max. supply current Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature E9 R C3F Dimensions Length A x width B x height C 9 E16 R C3F C version mm Note 16 148 x 109 x 72 18 20 (*) Observe the max. permissible current for the common wires 17 19 Ordering data Note Type RS16E-OD 24-48V H/V C : compact version Accessories Note B.40 Optocoupler - 4061180000 C Order No. 9446900000 FUS + + - Supply Voltage 24-48 V version For 16-channel digital cards PLC Interfaces H-, R- and S-System Opto-Decoupled Inputs for Digital Cards RSE OD – 16-channel Dimensions System H – Pluggable optocouplers Version: screw connection C B C B A Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Operating Voltage Input current AC Input current DC Switching voltage AC Switching voltage DC Max. switching current/voltage Optocoupler polarisation voltage Continuous current per optocoupler Fuse (optocoupler power supply) I/O card max. supply current Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) C1 Connector HE10/20 poles 115 V UC / 230 V AC 7 mA AC / 7 mA AC 7 mA DC / – 80 V AC / 150 V AC 75 V DC / – 100 mA / 48 V– 24 up to 48 V DC 100 mA 1A 2A FUS C2 E1 R 250 V AC III 2 1.2 KVrms -25…40 ºC -40…60 ºC 1 E8 R C1F 8 C3 C4 FUS Input PCB Connector C1F E9 R C3F Dimensions Length A x width B x height C 9 E16 R C3F C version mm Note 16 148 x 109 x 72 18 20 (*) Observe the max. permissible current for the common wires (**) No main-circuits 17 19 Ordering data Note Type RS16E-OD 115 H/V RS16E-DO 230V H/V C : compact version (1) Available upon customer request C C Order No. 9446910000 (1) 9446920000 (1) FUS + + - Supply Voltage 115 V version 230 V version Accessories Note Optocoupler - 4061180000 B.41 PLC Interfaces H-, R- and S-System Module Overview - Relay Outputs for Digital Cards Type Functionalities Connection No. of channels H or R System Compact version 8 chan. H System C C V 12 chan. H System C V B Screw Tension c. V 16 channels H System C C C C C V V V V V V V 32 channels H System C C V V Note: Preferred articles in bold B.42 Z Z Z Z Type of contact Modules Fuse Order No. Type Page 9445000000 RSM8C-1CO H/V B.43 1CO 9447000000 RSM8C-1CO H/Z B.43 1CO 9445060000 (*) RSM12C-1CO H/V 1CO 9444610000 RSM16-NV/1CO 24V (-/+) B.45 1CO 9444660000 RSM16-NZ/1CO 24V (-/+) B.45 1CO 9445100000 RSM16C-1CO H/V B.46 1CO 9447100000 RSM16C-1CO H/Z B.46 1CO 1079390000 (*) RSM16 SLIM-1CO H/V 1CO 1094970000 (*) RSM16 SLIM-1CO H/V SOCKET B.47 2CO 9445160000 RSM16-2CO H/V B.48 9447160000 RSM16-2CO H/Z B.48 9445140000 RSM16-1CO-Fo H/V B.49 9445120000 RSM16-1CO-Fu H/V B.50 9447120000 RSM16-1CO-Fu H/Z B.50 9445180000 RSM16 1T/Solen. ctrl 24V DC H/V B.51 2CO 1CO 1CO F F 1NO Z Solen. ctrl. 1CO 1CO Z Force function P E B.44 B.47 1CO 1108470000 (*) RSM32C-1CO 24VDC H/V B.52 1CO 9447200000 RSM32C-1CO H/Z B.52 9445220000 RSM32-1CO-Fu H/V B.53 1CO F (*) Available upon customer request For 8-channel digital output cards PLC Interfaces H-, R- and S-System Relay Outputs for Digital Cards RSM-C – 8-channel Dimensions H System – 1CO relay Versions: screw / tension clamp B C B A Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Coil rated voltage Coil rated current/power Coil status indicator PLC card supply current fuse I/O card max. supply current Output data Contact configuration Max. switching power/voltage Relay type Max. continuous/inrush current Contact material Fuse (contact) Mechanical service life Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature 24 V ±10% 17 mA / 0.4 W LED green 3.15 A 2A Output PCB Connector 1CO 3000 VA / 250 V AC 16 A version 5 A/16 A AgNi 90/10 – 30 x 106 operations mm Note Relay 1 21 24 22 31 34 32 Relay 2 81 84 82 Relay 8 Relay 3 Supply Voltage 250 V AC III 2 1.2 KVrms -25…40 ºC -40…60 ºC 11 14 12 110 x 109 x 68 (*) No main-circuits + +F 1 2 3 8 Connector HE10/20 poles Dimensions Length A x width B x height C HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14) 18 20 FUS 17 19 Ordering data Screw connection Tension clamp connection Type RSM8C-1CO H/V RSM8C-1CO H/Z Order No. 9445000000 9447000000 Note Accessories Note Relay RCL314024 - 8693260000 Static relay ODC - 8576340000 Static relay OAC - 8576370000 B.43 PLC Interfaces H-, R- and S-System Relay Outputs for Digital Cards For 12-channel digital output cards RSM-C – 12-channel Dimensions H System – 1CO relay Version: screw connection B C B A Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Coil rated voltage Coil rated current/power Coil status indicator PLC card supply current fuse I/O card max. supply current Output data Contact configuration Max. switching power/voltage Relay type Max. continuous/inrush current Contact material Fuse (contact) Mechanical service life HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) – 24 V ±10% 17 mA / 0.4 W LED green 3.15 A 2A 250 V AC III 2 1.2 KVrms -25…40 ºC -40…60 ºC mm Note 147 x 109 x 68 (*) No main-circuits Ordering data Screw connection Tension clamp connection Type RSM12C-1CO H/V Order No. 9445060000 Note Accessories Note B.44 Relay RCL314024 - 869326000 Relay 1 21 24 22 31 34 32 Relay 2 121 124 122 Relay 12 Relay 3 Supply Voltage Dimensions Length A x width B x height C Output PCB Connector Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature 11 14 12 Static relay ODC - 8576340000 Static relay OAC - 8576370000 + +F 1 2 3 12 18 20 FUS 17 19 HE 10 20-pole connector Connector HE10/20 poles 1CO 3000 VA / 250 V AC 16 A version 5 A/16 A AgNi 90/10 – 30 x 106 operations For 16-channel digital output cards PLC Interfaces H-, R- and S-System Relay Outputs for Digital Cards RSM-S – 16-channel Dimensions 1CO relay Versions: screw / tension clamp B C B A Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Coil rated voltage Coil rated current/power Coil status indicator PLC card supply current fuse I/O card max. supply current Output data Contact configuration Max. switching power/voltage Relay type Max. continuous/inrush current Contact material Fuse (contact) Mechanical service life Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature 1CO 3000 VA / 250 V AC 16 A version 5 A/16 A AgNi 90/10 – 30 x 106 operations Output PCB Connector 11 14 12 250 V AC III 2 1.2KVrms -25…40 ºC -40…60 ºC mm Note Relay 1 1 E1 21 24 22 31 34 32 Relay 2 2 E2 Relay 3 3 E3 161 164 162 267 x 87.5 x 68 Input PCB Connector 24 V ±10% 22 mA / 0.5 W LED green – 2A Connector HE10/20 poles Relay 16 16 E16 (*) No main-circuits Ordering data Screw connection Tension clamp connection Type RSM16-NV/1CO 24V (-/+) RSM16-NZ/1CO 24V (-/+) Order No. 9444610000 9444660000 Supply Voltage Dimensions Length A x width B x height C HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26) COM 18 20 U 17 19 Note Accessories Note Relay RCL314024 - 8693260000 Static relay ODC - 8576340000 Static relay OAC - 8576370000 B.45 PLC Interfaces H-, R- and S-System Relay Outputs for Digital Cards For 16-channel digital output cards RSM-C – 16-channel Dimensions H System – 1CO relay Versions: screw / tension clamp B C B A Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Coil rated voltage Coil rated current/power Coil status indicator PLC card supply current fuse I/O card max. supply current Output data Contact configuration Max. switching power/voltage Relay type Max. continuous/inrush current Contact material Fuse (contact) Mechanical service life HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14) 24 V ±10% 17 mA / 0.4 W LED green 3.15 A 2A mm Note 185 x 109 x 68 (*) No main-circuits Ordering data Screw connection Tension clamp connection Type RSM16C-1CO H/V RSM16C-1CO H/Z Order No. 9445100000 9447100000 Note Accessories Note B.46 Relay RCL314024 - 8693260000 Relay 1 21 24 22 31 34 32 Relay 2 161 164 162 Relay 16 Relay 3 Supply Voltage Dimensions Length A x width B x height C 250 V AC III 2 1.2 KVrms -25…40 ºC -40…60 ºC 11 14 12 Static relay ODC - 8576340000 Static relay OAC - 8576370000 + +F 1 2 3 16 18 20 FUS 17 19 Connector HE10/20 poles Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Output PCB Connector 1CO 3000 VA / 250 V AC 16 A version 5 A/16 A AgNi 90/10 – 30 x 106 operations For 16-channel digital output cards PLC Interfaces H-, R- and S-System Relay Outputs for Digital Cards RSM SLIM – 16-channel Dimensions H System – with 1CO relay / empty socket Version: screw connection - compact B C C B A Technical data C version mm Note 24 V ±10% 8 mA / 0.2 W LED green – 2A Output PCB Connector 1CO 1500 VA / 250 V AC 6 A version 4 A/6 A AgSnO2 – 5 x 106 operations 250 V AC III 2 1.2 KVrms -25…40 ºC -40…60 ºC 11 14 12 Relay 1 21 24 22 31 34 32 Relay 2 161 164 162 Relay 16 Relay 3 Supply Voltage Dimensions Length A x width B x height C HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14) 111 x 87.5 x 85 (*) No main-circuits + 1 2 3 16 Connector HE10/20 poles Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Coil rated voltage Coil rated current/power Coil status indicator PLC card supply current fuse I/O card max. supply current Output data Contact configuration Max. switching power/voltage Relay type Max. continuous/inrush current Contact material Fuse (contact) Mechanical service life Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature 18 20 17 19 Ordering data Equipped with 1 CO relay screw connection Empty slot, screw connection Note Type RSM16 SLIM-1CO H/V RSM16 SLIM-1CO H/V SOCKET C C Order No. 1079390000 (1) 1094970000 (1) C : compact version (1) Available upon customer request Accessories Note 1CO relay - 4061590000 Optocoupler ODC 24V/2A - 4061190000 B.47 PLC Interfaces H-, R- and S-System Relay Outputs for Digital Cards For 16-channel digital output cards RSM-2CO – 16-channel Dimensions System H – 2CO relay Versions: screw / tension clamp B C B A Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Coil rated voltage Coil rated current/power Coil status indicator PLC card supply current fuse I/O card max. supply current Output data Contact configuration Max. switching power/voltage Relay type Max. continuous/inrush current Contact material Fuse (contact) Mechanical service life HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14) Output PCB Connector 2CO 2000 VA / 250 V AC 2x8 A version 4 A/8 A AgNi 90/10 – 30 x 106 switching cycles 121 111 114 112 211 214 Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Connector HE10/20 poles 24 V ±10% 17 mA / 0.4 W LED green 3.15 A 2A 212 250 V AC III 2 1.2 KVrms -25…40 ºC -40…60 ºC 311 314 Relay 1 1 Relay 2 2 Relay 3 3 Relay 16 16 124 122 221 224 222 331 334 332 312 1621 1624 1611 1622 1614 mm Note 1612 263 x 109 x 75 Supply Voltage Dimensions Length A x width B x height C (*) No main-circuits Ordering data Screw connection Tension clamp connection Type RSM16-2CO H/V RSM16-2CO H/Z Note Accessories Note B.48 2CO Relay - 4058570000 Order No. 9445160000 9447160000 + +F 18 20 FUS 17 19 For 16-channel digital output cards PLC Interfaces H-, R- and S-System Relay Outputs for Digital Cards RSM-Fo - 16-channel with force function Dimensions H System – 1CO relay Version: screw connection B C B A A Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Coil rated voltage Coil rated current/power Coil status indicator PLC card supply current fuse I/O card max. supply current Output data Contact configuration Max. switching power/voltage Relay type Max. continuous/inrush current Contact material Fuse (contact) Mechanical service life Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature 24 V ±10% 17 mA / 0.4 W LED green 3.15 A 2A Switch 1CO 3000 VA / 250 V AC 16 A version 2 A/16 A AgNi 90/10 – 30 x 106 operations Output PCB Connector 11 14 12 250 V AC III 2 1.2 KVrms -25…40 ºC -40…60 ºC Note SW2 161 164 162 SW16 Relay 2 Relay 3 SW3 Relay 16 2 3 16 263 x 109 x 75 (*) No main-circuits Ordering data Screw connection Tension clamp connection 21 24 22 31 34 32 Supply Voltage mm 1 SW1 Connector HE10/20 poles Dimensions Length A x width B x height C HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) – Type RSM16-1CO-Fo H/V + +F 18 20 FUS 17 19 Order No. 9445140000 Note Accessories Note Relay RCL314024 - 8693260000 Static relay ODC - 8576340000 Static relay OAC - 8576370000 B.49 PLC Interfaces H-, R- and S-System Relay Outputs for Digital Cards For 16-channel digital output cards RSM-Fu – 16-channel with fuse Dimensions H System – 1CO relay Versions: screw / tension clamp B C B A A Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Coil rated voltage Coil rated current/power Coil status indicator PLC card supply current fuse I/O card max. supply current Output data Contact configuration Max. switching power/voltage Relay type Max. continuous/inrush current Contact material Fuse (contact) Mechanical service life HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.5...1.5 / 0.5...1.5 mm2 (AWG 16...26) 24 V ±10% 17 mA / 0.4 W LED green 3.15 A 2A mm Note 261 x 109 x 75 (*) No main-circuits Ordering data Screw connection Tension clamp connection Type RSM16-1CO-Fu H/V RSM16-1RT-Fu H/Z Order No. 9445120000 9447120000 Note Accessories Note B.50 Relay RCL314024 - 8693260000 FUS 21 24 22 31 34 32 FUS 161 164 162 FUS Static relay ODC - 8576340000 Static relay OAC - 8576370000 Relay 1 Relay 2 Relay 3 FUS Supply Voltage Dimensions Length A x width B x height C 250 V AC III 2 1.2 KVrms -25…40 ºC -40…60 ºC 11 14 12 Relay 16 + +F 1 2 3 16 18 20 FUS 17 19 Connector HE10/20 poles Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Output PCB Connector 1CO 3000 VA / 250 V AC 16 A version 5 A/16 A AgNi 90/10 5 A fuse on each channel 30 x 106 operations For 16-channel digital output cards PLC Interfaces H-, R- and S-System Relay Outputs for Digital Cards RSM-Solen. ctrl. - 16-channel for solenoid Dimensions H System – 1O relay Version: screw connection B C B A Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Coil rated voltage Coil rated current/power Coil status indicator PLC card supply current fuse I/O card max. supply current Output data Contact configuration Max. switching power/voltage Relay type Max. continuous/inrush current Contact material Fuse (contact) Mechanical service life Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) – 24 V ±10% 17 mA / 0.4 W LED green 3.15 A 2A C1 C2 1CO 3000 VA / 250 V AC 16 A version 2 A/16 A AgNi 90/10 – 30 x 106 operations Relay 1 I1 250 V AC III 2 1.2 KVrms -25…40 ºC -40…60 ºC FUS Relay 8 I8 F8 FUS C3 C4 Relay 9 I9 F9 Relay 16 Note F16 290 x 109 x 75 (*) No main-circuits Ordering data Screw connection Tension clamp connection Type RSM16 1T/Solen. ctrl. 24V DC H/V 16 FUS Supply Voltage mm 9 FUS I16 Dimensions Length A x width B x height C 8 Connector HE10/20 poles Output PCB Connector F1 1 + +F 18 20 FUS 17 19 Order No. 9445180000 Note Accessories Note Relay RCL314024 - 8693260000 Static relay ODC - 8576340000 Static relay OAC - 8576370000 B.51 PLC Interfaces H-, R- and S-System Relay Outputs for Digital Cards For 32-channel digital output cards RSM-C – 32-channel Dimensions H System – 1 CO relay Versions: screw / tension clamp B C B A Technical data 24 V ±10% 17 mA / 0.4 W LED green 3.15 A 2A Relay 1 21 24 22 31 34 32 Relay 2 161 164 162 Relay 16 Relay 3 365 x 109 x 68 (*) No main-circuits + 1 2 3 16 18 20 17 19 FUS +F 171 174 172 Relay 17 181 184 182 191 194 192 Relay 18 321 324 322 Relay 32 Relay 19 1 2 3 Screw connection Tension clamp connection Note Type RSM32C-1CO 24VDC H/V RSM32C-1CO H/Z Order No. 1108470000 (1) 9447200000 (1) Available upon customer request Accessories Note B.52 Relay RCL314024 - 8693260000 Static relay ODC - 8576340000 Static relay OAC - 8576370000 Supply Voltage 2 Ordering data + +F 16 18 20 FUS 17 19 Connector (2) HE10/20 poles Note Output PCB Connector 250 V AC III 2 1.2 KVrms -25…40 ºC -40…60 ºC mm 11 14 12 Supply Voltage 1 1CO 3000 VA / 250 V AC 16 A version 5 A/16 A AgNi 90/10 – 30 x 106 operations Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C Output PCB Connector 2 x HE 10 connector - 20 pole 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14) Connector (1) HE10/20 poles Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Coil rated voltage Coil rated current/power Coil status indicator PLC card supply current fuse I/O card max. supply current Output data Contact configuration Max. switching power/voltage Relay type Max. continuous/inrush current Contact material Fuse (contact) Mechanical service life For 32-channel digital cards PLC Interfaces H-, R- and S-System Relay Outputs for Digital Cards RSM-Fu – 32-channel with fuse Dimensions H System – 1 CO relay Version: screw connection B C B A A Technical data Output PCB Connector 24 V ±10% 17 mA / 0.4 W LED green 3.15 A 2A 250 V AC III 2 1.2 KVrms -25…40 ºC -40…60 ºC mm FUS 21 24 22 31 34 32 FUS 161 164 162 FUS 511 x 109 x 75 (*) No main-circuits Relay 1 Relay 2 Relay 3 FUS Relay 16 + FUS 181 184 182 191 194 192 FUS 321 324 322 FUS 2 3 16 18 20 17 19 FUS +F 171 174 172 1 Relay 17 Relay 18 Relay 19 FUS 1 2 3 Screw connection Tension clamp connection Type RSM32-1CO-Fu H/V Order No. 9445220000 Note Accessories Note Relay RCL314024 - 8693260000 Static relay ODC - 8576340000 Static relay OAC - 8576370000 Supply Voltage 2 Ordering data Relay 32 + +F 16 Connector (2) HE10/20 poles Note 11 14 12 Supply Voltage 1 1CO 3000 VA / 250 V AC 16 A version 5 A/16 A AgNi 90/10 5 A fuse on each channel 30 x 106 operations Output PCB Connector Dimensions Length A x width B x height C 2 x HE 10 20-pole connectors 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) – Connector (1) HE10/20 poles Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input data Coil rated voltage Coil rated current/power Coil status indicator PLC card supply current fuse I/O card max. supply current Output data Contact configuration Max. switching power/voltage Relay type Max. continuous/inrush current Contact material Fuse (contact) Mechanical service life Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature 18 20 FUS 17 19 B.53 PLC Interfaces H-, R- and S-System Module Overview – Analog Input/Output B Type Number of channels 4 channels 8 channels PLC Standard Standard 8 Premium channels P (Télémécanique) 9 Micro channels M (Télémécanique) 16 channels Standard Functionalities Compact version Connection Screw Tension c. Common distribution Disconnectable Test points V V M M I T V V M M M I I T T M I Z V V V V Z Note: Preferred articles in bold B.54 Modules M M M I I T T Order No. Type Page 9448000000 RS4AIO-DP SD/V B.55 9448100000 RS4AIO/I-M-DP SD/V B.55 9448010000 RS8AIO-DP SD/V B.56 9448110000 RS8AIO/I-M-DP SD/V B.56 9449110000 RS8AIO/I-M-DP SD/Z B.56 9448030000 RS8AI PREM/APR SD/V B.57 9448040000 RS8E1AO MICRO SD/V B.57 9448020000 RS16AIO-DP SD/V B.58 9448120000 RS16AIO/I-M-DP SD/V B.58 9449120000 RS16AIO/I-M-DP SD/Z B.58 For 4-channel analog I/O cards RS AIO-DP - 4-channel RS AIO/I-M-DP - 4-channel Common distribution Version: screw connection Common distribution, disconnection and test Version: screw connection Dimensions B Disconnectable connector B 3 0- 11 1+ 4 1- 12 C 0- 3- 14 SubD male A Shunt Supply Voltage C + C + I/O PCB Connector 6 ConnectorSubD 15 poles 3+ 1 9 +F Shielded C 1+ 4 1- 12 3+ 6 3- 14 C 2 10 FUS 11 C Shunt C C 3 Test point C Supply Voltage I/O PCB Connector C 0+ C C + C + Connector SubD 15 poles 0+ C 2 10 1 9 FUS +F Shielded C Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Number of channels Operating voltage Common distribution PLC card supply current fuse Disconnection Current measuring test point Voltage measuring test point Continuous shielding Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C mm 15-pole D-SUB male connector 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) – 15-pole D-SUB male connector 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) – 4 ≤ 25 V AC 50 V DC Shield, + or – (selectable with jumper) 3.15 A – – – Yes 4 ≤ 25 V AC 50 V DC Shield, + or – (selectable with jumper) 3.15 A Yes - each channel Yes - 2 female testing points dia. 4 mm Yes Yes < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC 75 x 87.5 x 72 73 x 109 x 81 Note Ordering data Screw connection Tension clamp connection Type RS4AIO-DP SD/V Order No. 9448000000 Type RS4AIO/I-M-DP SD/V PLC Interfaces H-, R- and S-System Input / Output for Analog Cards Order No. 9448100000 Note B.55 RS AIO-DP - 8-channel RS AIO/I-M-DP - 8-channel Common distribution Version: screw connection Common distribution, disconnection and test Versions: screw / tension clamp Dimensions Disconnectable connector B 3 0- 16 1+ 4 1- 17 0+ 0- 7- 23 A Shunt C + C + I/O PCB Connector 10 Connector SubD 25 poles 7+ 1 14 +F Shielded C 1+ 4 1- 17 7+ 10 7- 23 C 2 15 FUS 16 C Shunt C C Test point C Supply Voltage I/O PCB Connector C C 3 C C + C + Connector SubD 25 poles 0+ C Supply Voltage B For 8-channel analog I/O cards SubD male PLC Interfaces H-, R- and S-System Input / Output for Analog Cards 2 15 1 14 FUS +F Shielded C Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Number of channels Operating voltage Common distribution PLC card supply current fuse Disconnection Current measuring test point Voltage measuring test point Continuous shielding Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C mm 25-pole D-SUB male connector 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) – 25-pole D-SUB male connector 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14) 8 ≤ 25 V AC 50 V DC Shield, + or – (selectable with jumper) 3.15 A – – – Yes 8 ≤ 25 V AC 50 V DC Shield, + or – (selectable with jumper) 3.15 A Yes - each channel Yes - 2 female testing points dia. 4 mm Yes - 2 female testing points dia. 4 mm Yes < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC 117 x 87.5 x 72 114 x 109 x 81 Note Ordering data Screw connection Tension clamp connection Note B.56 Type RS8AIO-DP SD/V Order No. 9448010000 Type RS8AIO/I-M-DP SD/V RS8AIO/I-M-DP SD/Z Order No. 9448110000 9449110000 For Télémécanique Premium and Micro PLC analog I/O cards RS8AI PREM/APR – 8-channel RS8I1OA MICRO – 9-channel 8 analog inputs Version: screw connection 8 analog inputs and 1 output Version: screw connection PLC Interfaces H-, R- and S-System Input / Output for Analog Cards B Dimensions Shunt 0+ IV C 0- IC 1+ IV C 16 IC 2+ IV 2- 5 4 17 IC 7+ IV 1 S0- 2 E0+ 10 E0- 14 E1+ 3 25 E1E2+ 11 E2- E7+ E7- 6 24 15 10V 7- 12 C SubD male Shunt A + C Connector SubD 15 poles 3 C S0+ 15 Connector SubD 25 poles 1C Input PCB Connector 1 14 C C 2 I/O PCB Connector B IC GND 10V GND 10V GND + 10V GND Shielded 10V GND Shielded C Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Number of channels Operating voltage Common distribution PLC card supply current fuse Disconnection Current measuring test point Voltage measuring test point Continuous shielding Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C mm Note 25-pole D-SUB male connector 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) – 15-pole D-SUB male connector 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) – 8 ≤ 25 V AC 50 V DC Shield, + or – (selectable with jumper) – Yes – – Yes 9 ≤ 25 V AC 50 V DC Shielding – – – Yes Yes < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC < 50 V AC II 2 0.5 KV DC -25…50 ºC -40…60 ºC 116 x 87.5 x 72 100 x 87.5 x 72 Current/Voltage Switchable Ordering data Screw connection Tension clamp connection Type RS8AI PREM/APR SD/V Order No. 9448030000 Type RS8I1OA MICRO SD/V Order No. 9448040000 Note B.57 RS AIO-DP - 16-channel RS AIO/I-M-DP - 16-channel Common distribution Version: screw connection Common distribution, disconnection and test Version: screw / tension clamp Dimensions Disconnectable connector B 0+ 3 0- 22 1+ 4 1- 23 C 0+ 0- 37 + C + 2 21 1 20 FUS +F Shielded C 1+ 4 1- 23 15+ 18 15- 37 C C Supply Voltage Shunt C I/O PCB Connector 18 15- Connector SubD 37 poles 15+ 22 C Shunt C C A Test point C + C + Connector SubD 37 poles I/O PCB Connector C 3 C C Supply Voltage B For 16-channel analog I/O cards SubD male PLC Interfaces H-, R- and S-System Input / Output for Analog Cards 2 21 1 20 FUS +F Shielded C Technical data Connection Connection to PLC Connection type V (screw clamp) Flexible/Solid Connection type Z (tension clamp) Flexible/Solid Input-Output Data Number of channels Operating voltage Common distribution PLC card supply current fuse Disconnection Current measuring test point Voltage measuring test point Continuous shielding Insulation coordination (EN50178) Rated voltage Overvoltage category Pollution degree Insulation test voltage Ambient temperature Storage temperature Dimensions Length A x width B x height C mm 37-pole D-SUB male connector 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) – 37-pole D-SUB male connector 0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12) 0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14) 16 ≤ 25 V AC 50 V DC Shield, + or – (selectable with jumper) 3.15 A – – – Yes 16 ≤ 25 V AC 50 V DC Shield, + or – (selectable with jumper) 3.15 A Yes - each channel Yes - 2 female testing points dia. 4 mm Yes - 2 female testing points dia. 4 mm Yes < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC < 50 V AC III 2 0.5 KV DC -25…50 ºC -40…60 ºC 205 x 87.5 x 72 197 x 109 x 81 Note Ordering data Screw connection Tension clamp connection Note B.58 Type RS16AIO-DP SD/V Order No. 9448020000 Type RS16AIO/I-M-DP SD/V RS16AIO/I-M-DP SD/Z Order No. 9448120000 9449120000