Download

PLC Interfaces
H-, R- and S-System
Contents
PLC Interfaces
H-, R- and S-System
PLC Interfaces
Universal Precabling for PLCs
B.2
Selection Guide
B.5
Direct Inputs / Outputs for Digital Cards
B.21
Opto-Decoupled Inputs for Digital Cards
B.39
Relay Outputs for Digital Cards
B.42
Input/Output for Analog Cards
B.54
B.1
B
PLC Interfaces
H-, R- and S-System
Universal Precabling for PLCs
B
PLC interface systems
The complexity of machines and installations in industry, processing or building is
giving rise to ever-increasing cabling
costs. The traditional wire to wire cabling
between the PLC and the inputs/outputs
is very expensive during installation and
commissioning. The PLC interface system
offers the user an easy and quick-to-install
solution for wiring the inputs and outputs
of the SIEMENS SIMATIC® S7.
Wire to wire cabling
Wiring interface system
Most PLC I/O cards use two types
of connection:
The basic idea is that the PLC’s I/O cards
are connected to the active or passive I/O
modules using prefabricated cables. Front
adapters are directly plugged into the
PLC’s I/O cards. The adapter internally
converts the PLC-specific connectors to
an HE connector for ribbon cable (in accordance with IEC 603-1/ DIN 41651). The
active or passive I/O modules can thus be
used independently of the type of PLC.
• screw,
• tension clamp.
In each case, the signals are connected
individually to each connection component.
Disadvantages of wire to wire cabling:
Special front adapters replace the
usual screwed connectors used for
the I/O cards of the PLC. The signals
from the PLC are sent to the active or
passive components by means of a
prefabricated lead fitted with a 20-pole
female connector.
• high assembly costs,
• risk of error increasing with the number
of wires connected,
The wiring interface system has the following advantages over wire to wire cabling:
• large amount of space taken up in
the cabinet,
• minimum wiring costs,
• high installation costs,
• the commissioning and the production
of wiring drawings is simplified.
• a lot of time taken up in preparing and
laying the wires,
• a large amount of time taken up in producing wiring diagrams and drawings.
• reduced installation time,
The family of PLC interface modules allows the inputs/outputs for main PLC
manufacturers to be quickly and easily
connected.
PLC
PLC
B.2
PLC Interfaces
H-, R- and S-System
Universal Precabling for PLCs
PLC interface systems
Advantages of the system:
• Quick
– reduced design times,
– time saved during installation,
– reduced commissioning and troubleshooting times,
B
Inputs
• Reliable
Outputs
– reduced on-site wiring times thanks to
the prefabricated cables.
– no wiring errors,
– clear wiring in the cabinet (cable system
instead of individual wires),
– labelling corresponding to that of the
PLC,
– additional individual labelling.
• Flexible
– many input/output modules (about 40
possibilities),
– variable cable lengths,
– modularity of all components,
– configuration of 1 x 4 bytes and 2 x 2
bytes without distributor,
– option to mix functions by byte at the
I/Os,
– extensions possible without any
problem,
– flexibility thanks to the ease in
exchanging input/output interfaces.
• Takes up only a small amount of
space
– more space in the cable ducts,
– narrow modules,
– no terminal block.
B.3
PLC Interfaces
H-, R- and S-System
Universal Precabling for PLCs
Weidmuller universal precabling for PLCs
System H ...
… screw or tension clamp, standard or compact
B
Weidmuller’s system H was developed for all PLC types and can be adapted
to suit all situations. Particularly economic, it is characterized by:
Connector type HE, 10/20 pins, fully protected:
extruded-insulation cable, polarized, secure connection
precabling to PLC – 0.25 mm2 (LIYY)
Relay outputs – System H
connection type selection:
screw or tension clamp
new compact modules, reducing the size of the cabinet
Input/output of interface modules boards
for digital signals: 4, 8, 12, 16 and 32-channel
System R …
… with the RSV 1.6 industrial connector
Thanks to its industrial connector, system R enables the connection of input
signals to a higher voltage of up to 160 V or 250 V.
It is characterized by:
connector type RSV 1.6 (250 V DC 8 A)
precabling to PLC – 0.25 mm2 (LIYY)
input/output interface module boards for digital signals 8, 16, 32-channel
Direct inputs – System R
System S …
… with shielded Sub-D connector
The sub-d metallic housing is ideal for the transmission of analog signals:
Connector sub-d female 15, 25, 37 poles
Precabling to PLC – 0.25 mm2 shielded (LYC)
Input/output interface module boards with PE.
Analog input/outputs – System S
B.4
EVEN SIMPLER TO USE …
… thanks to the new “Selection guide” available on CD or download
This new guide available on CD or from our Web site enables you to make
rapid searches for interface modules and compatible cables for a PLC and
to display the corresponding technical data.
PLC Selection Guide
• PLC selection
• I/O card selection
• Displays all interface modules and the compatible cable
• Displays the technical data for the selected interface module and
ribbon cable
B
Download Selection Guide http://www.weidmuller.com
Using the selection guide
PLC Interfaces
H-, R- and S-System
Selection guide
‚
Select the PLC card from the corresponding table
ƒ
Look up the order number for the cable and the
quantity to be ordered
PLC Siemens - S7-300
PLC
Cables
I/O cards
Standard
Digital input
Manufacturer order number
H , R and S System
C
Qty
Order No.
7789234xxx
7789236xxx
7789247XXX
7789212xxx
7789234xxx
7789210xxx
7789219xxx
7789215xxx
7789211xxx
7789234xxx
7789234xxx
7789236xxx
7789246XXX
7789246XXX
7789211xxx
7789239xxx
7789219xxx
7789220xxx
7789239xxx
7789214xxx
7789211xxx
7789190xxx
7789191xxx
7789192xxx
7789192xxx
7789237xxx
7789236xxx
7789221xxx
7789222xxx
7789222xxx
7789222xxx
7789223xxx
6ES7 314-6CF00-0AB0 (314C-2DP) 7789222xxx
7789223xxx
6ES7 314-6BF00-0AB0 (314C-2PtP) 7789222xxx
7789223xxx
7789229xxx
6ES7 331-7KF01-0AB0
7789231xxx
6ES7 331-7NF00-0AB0
7789193xxx
6ES7 331-7RD00-0AB0
7789194xxx
6ES7 331-7RD00-0AB0
7789229xxx
6ES7 331-7SF00-0AB0
7789230xxx
6ES7 331-7PF00-0AB0
6ES7 331-7KB01 / 7KB81-0AB0 7789224xxx
7789228xxx
6ES7 332-5HD01-0AB0
7789227xxx
6ES7 332-5HD01-0AB0
6ES7 332-5HB01 / 5HB81-0AB0 7789228xxx
6ES7 332-5HB01 / 5HB81-0AB0 7789227xxx
7789228xxx
6ES7 332-7ND00-0AB0
7789227xxx
6ES7 332-7ND00-0AB0
7789195xxx
6ES7 332-5RD00-0AB0
7789233xxx
6ES7 332-5HF00-0AB0
7789196xxx
6ES7 334-0KE00-0AB0
7789226xxx
6ES7 335-7HG01-0AB0
7789225xxx
6ES7 334-0CE01-0AA0
6ES7 321-1BH01 / 1BH81-0AA0
6ES7 321-1BL00 / 1BL80-0AA0
6ES7 321-1BP00-0AA0
6ES7 321-1EH01-0AA0
6ES7 321-1BH50-0AA0
6ES7 321-7BH00 / 7BH80-0AB0
6ES7 321-1FF01 / 1FF81-0AA0
6ES7 321-1EL00-0AA0
6ES7 321-1CH80-0AA0
6ES7 321-7RD00-0AB0
6ES7 322-1BH01 / 1BH81-0AA0
6ES7 322-1BL00-0AA0
6ES7 322-1BP00-0AA0
6ES7 321-1BP50-0AA0
6ES7 322-1EH01-0AA0
6ES7 322-1BF01-0AA0
6ES7 322-1FF01 / 1FF81-0AA0
6ES7 322-1HF01-0AA0
6ES7 322-8BF00-0AB0
6ES7 322-1HH00-0AA0
6ES7 322-1EL00-0AA0
6ES7 322-1HF10 / 1HF80-0AA0
6ES7 322-1CF80-0AA0
6ES7 322-5SD00-0AB0
6ES7 322-5RD00-0AB0
6ES7 323-1BH00 / 1BH80-0AA0
6ES7 323-1BL00-0AA0
6ES7 312-5BD00-0AB0 (312C)
6ES7 313-6CE00-0AB0 (313C-2DP)
6ES7 313-6BE00-0AB0 (313C-2PtP)
6ES7 313-5BE00-0AB0 (313C)
Interfaces
1
1
2
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Order No.
Digital output
Digital
I/O
I/O cards
7789293xxx
7789293xxx
1
2
7789293xxx
1
7789293xxx
7789293xxx
1
2
ital input
Digital and
Anal. I/O
Anal. Input
Anal. Output
Anal.
I/O
Digital relay
output
- see page C.42 -
7789293xxx
6ES7 321-1BH01 / 1BH81-0AA0
6ES7 321-1BL00 / 1BL80-0AA0
6ES7 321-1BP00-0AA0
6ES7 321-7BH00 / 7BH80-0AB0
Qty
Type
16-channel - H
32-channel - H
32-channel - H
16-channel - R
16-channel - H
16-channel - R
8-channel - R
32-channel - R
16-channel - R
16-channel - H
B)
A, B)
16-channel
16-channel
)
Qty
B)
B)
Type
Order No.
Type
Qty
1
2
2
16-channel
32-channel
32-channel
32-channel
16-channel - R
16-channel - R
16-channel - R
8-channel - R
8-channel - H
8-channel - H
8-channel - H
16-channel - H
12-channel - H
16-channel - H
16-channel - H
16-channel - H
8-channel - H
16-channel - H
8-channel - H
16-channel - H
8-channel - H
Anal.
input/output
C)
1
1
A, C)
Example:
• Cable order number 7789236xxx* - Qty 1
* see the note at the bottom of the page
A, C)
A, C)
1
8-channel
1
8-channel
1
8-channel
16-channel
8-channel
16-channel
16-channel
16-channel
1
1
1
1
1
1
1
1
D)
1
2
D)
1
Cables
1
1
1
1
1
1
1
1
1
1
1
1
1
1
E)
7789234xxx
7789236xxx
7789247XXX
1
1
2
7789212xxx
7789234xxx
1
1
7789210xxx
1
Int
SITOP 1Connection
16-channel
Qty
E)
1
2
16-channel
16-channel
7789293xxx
1
1
16-channel - H
8-channel P
32-channel
-1H
8-channel P
32-channel
-1H
8-channel
16-channel
4-channel
4-channel
8-channel
8-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
8-channel
8-channel
16-channel
16-channel
1
- see page C.38 -
Qty
Type
8-channel P
1
Digital optodecoupled input
- see page C.20 -
Qty
Order No.
7789293xxx
7789293xxx
Digital Direct
I/Os
B)
A, B)
1
1
A, B)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Q
Type
16-channel
16-channel
B)
„
16-channel - R
16-channel - H
1
1
16-channel - R
1
Look up the exact module family and the quantity to
be ordered
B)
Example:
• 32-channel system H - Qty. 1
or
• 16-channel opto-decoupled system H - Qty. 2
)
…
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example: Cable 2 metres in length: Order number: 7 7 8 9 2 3 6 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use Module
either a digitaloverview
direct input/output
module or
an opto-decoupled input
module
- Direct
inputs/outputs
for
digital
Example:
• PLC: Siemens S7-300
• Card: 6ES7 321-1BL00 / 1BL80-0AA0
- see page C.54 -
Qty
1
1
1
1
1
1
1
Standard
2
Type
1
1
A, B)
16-channel - R
8-channel - R
16-channel - R
Manufacturer order number
6ES7 321-1EH01-0AA0
6ES7 321-1BH50-0AA0
Digital optodecoupled input
- see page C.38 -
Qty
PLC Siemens - S7-300
PLC
Digital Direct
I/Os
- see page C.20 -
SITOP Connection
cards
Refer to the page whose number is given at the top
of the column
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
Example:
• Please refer to page B.21 Direct inputs/outputs for
digital cards
PLC Interfaces
H-, R- and S-System
E) Two channels unused
*
All I/O signals with same common.
*
Addional technical information about pre-assembled cable avaliable in ON-line catalog http://www.weidmueller.com
C.6
Type
No. of
channels
8
channels
12
chan.
Functionalities
Type of
wiring
2-wire
V
R System
2-wire
V
2-wire
V
L
V
V
L
H System
C
Compact
version
Connection
H or R
System
H System
Screw
C
C
C
C
2-wire
16
channels
3-wire
V
V
V
C
V
C
C
V
V
V
V
V
V
V
V
1-wire
R System
2-wire
3-wire
C
C
V
V
C
V
V
C
V
1-wire
H System
2-wire
32
channels
3-wire
1-wire
1 LED
per chan.
Disconnectable
Order No.
Fuse
L
Type
9445530000
RS 8ES-D-L H/V
9441540000 (*) RS8ES-DP RSV1,6/V
Page
C.21
V
C.21
3-wire
1-wire
H System
Tension c.
Modules
C
C
V
V
V
V
V
V
9445630000
RS 12ES-D-L H/V
9445700000
Z
Z
Z
Z
Z
9447700000
L
L
L
L
L
L
I
I
I
Z
Z
F
RS 16ES H/Z
C.23
C.23
9445810000
RS 16ES-S-I-L H/V
C.23
9445720000
RS 16ES-D H/V
C.24
9445730000
RS 16ES-D-L H/V
C.24
9447730000
RS 16ES-D-L
H/Z
H System
C.24
9445750000
RS 16ES-D-I-L H/V
I
I
I
L
L
I
F
C.24
C.25
9445760000
C.25
9445770000
C.25
RS 16ES-T-L H/Z
9441500000
RS16ES RSV1,6/V
9441860000
RS16ES-I RSV1,6/V
9441700000
RS16ES-DP RSV1,6/V
9441560000
RS16ES-DP/F RSV1,6/V
C.25
3-wireC.26
C.26
C
C
V
V
C
C
C
C
V
V
V
V
V
V
C.27
C.27
1-wireC.28
9445900000
RS 32ES H/V
C.29
9445910000
RS 32ES-L H/V
C.29
9447900000 (*) RS 32ES H/Z
L
L
L
L
L
L
C.24
2-wire
944582000032RS 16ES-D-F H/V
9441600000 (*) RS16E-3E/I RSV1,6/V
L
C.23
1-wireC.23
RS 16ES-L H/Z
9447770000
9441600000
RS16E 3E/I RSV1,6/V
C.28
9445900000
RS 32ES H/V
C.29
9445910000
RS 32ES-L H/V
C.29
C.22
9447710000
RS 16ES-T H/V
channelsRS 16ES-T-L H/V
L
L
I
Z
RS 16ES-L H/V
(*)
9447750000 (*) RS 16ES-D-I-L H/Z
F
I
Z
Z
RS 16ES H/V
9445710000
I
V
V
C.29
9447910000
RS 32ES-L H/Z
9445870000
RS 32ES-S-I-L H/V
C.30
9445930000
RS 32ES-D-L H/V
C.31
C.29
9447930000
RS 32ES-D-L H/Z
9445950000
RS 32ES-D-I-L H/V
C.32
9447950000 (*) RS 32ES-D-I-L H/Z
C.32
Z
Z
Z
Z
Z
L
9447900000 (*) RS 32ES H/Z
L
L
L
L
L
L
I
I
I
L
L
I
š
F
C.29
9447910000
RS 32ES-L H/Z
9445870000
RS 32ES-S-I-L H/V
C.30
9445930000
RS 32ES-D-L H/V
C.31
9447930000
RS 32ES-D-L H/Z
9445950000
RS 32ES-D-I-L H/V
C.32
9447950000 (*) RS 32ES-D-I-L H/Z
C.32
C.29
C.31
9445980000
RS 32ES-D-F H/V
C.33
9445960000
RS 32ES-T H/V
C.34
9445970000
RS 32ES-T-L H/V
C.34
9447970000
RS 32ES-T-L H/Z
C.34
9441510000
RS32ES RSV1,6/V
C.35
9441870000
RS32ES I RSV1 6/V
C 35
Select the module order number in the family
defined at stage 3
C.31
9445980000
RS 32ES-D-F H/V
C.33
9445960000
RS 32ES-T H/V
C.34
9445970000
RS 32ES-T-L H/V
C.34
9447970000
RS 32ES-T-L H/Z
C.34
9441510000
RS32ES RSV1,6/V
C.35
9441870000
RS32ES-I RSV1,6/V
C.35
* The suffix xxx in the order number shows the length of the cable in dm. the standard lengths
are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 4.00 m (040) - 5.00 m (050).
PLC Interfaces
H-, R- and S-System
Selection Guide
Example:
• Module order number 9445950000 – Qty. 1
32-channel module, 2-wire cabling, compact, version
with Led, interruptible
• Technical characteristics, page B.33
Note: it is also possible to use the catalog type of the cable.
In this case the suffix xxxx of the catalog type shows the length of the cable in cm. The standard lengths are: 1.00 m (0100) – 1.50 m (0150) – 2.00 m (0200) - 3.00 m (0300) – 4.00 m (0400) – 5.00 m (0500)
B.5
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC Siemens - S7-300
PLC
I/O cards
Cables
Standard
Interfaces
Digital Direct
I/Os
SITOP Connection
- see page B.21 -
Digital input
Manufacturer order number
Anal.
I/O
Anal. Output
Anal. Input
Digital and
Anal. I/O
Digital
I/O
Digital output
B
Order No.
7789234xxx
7789236xxx
7789247xxx
7789212xxx
7789234xxx
7789210xxx
7789219xxx
7789215xxx
7789211xxx
7789234xxx
7789234xxx
7789236xxx
7789246xxx
7789246xxx
7789211xxx
7789239xxx
7789219xxx
7789220xxx
7789239xxx
6ES7 322-8BF00-0AB0
7789214xxx
6ES7 322-1HH00-0AA0
7789211xxx
6ES7 322-1EL00-0AA0
6ES7 322-1HF10 / 1HF80-0AA0 7789190xxx
7789191xxx
6ES7 322-1CF80-0AA0
7789192xxx
6ES7 322-5SD00-0AB0
7789192xxx
6ES7 322-5RD00-0AB0
6ES7 323-1BH00 / 1BH80-0AA0 7789237xxx
7789236xxx
6ES7 323-1BL00-0AA0
7789221xxx
6ES7 312-5BD00-0AB0 (312C)
6ES7 313-6CE00-0AB0 (313C-2DP) 7789222xxx
6ES7 313-6BE00-0AB0 (313C-2PtP) 7789222xxx
7789222xxx
6ES7 313-5BE00-0AB0 (313C)
7789223xxx
6ES7 314-6CF00-0AB0 (314C-2DP) 7789222xxx
7789223xxx
6ES7 314-6BF00-0AB0 (314C-2PtP) 7789222xxx
7789223xxx
7789229xxx
6ES7 331-7KF01-0AB0
7789231xxx
6ES7 331-7NF00-0AB0
7789193xxx
6ES7 331-7RD00-0AB0
7789194xxx
6ES7 331-7RD00-0AB0
7789229xxx
6ES7 331-7SF00-0AB0
7789230xxx
6ES7 331-7PF00-0AB0
6ES7 331-7KB01 / 7KB81-0AB0 7789224xxx
7789228xxx
6ES7 332-5HD01-0AB0
7789227xxx
6ES7 332-5HD01-0AB0
6ES7 332-5HB01 / 5HB81-0AB0 7789228xxx
6ES7 332-5HB01 / 5HB81-0AB0 7789227xxx
7789228xxx
6ES7 332-7ND00-0AB0
7789227xxx
6ES7 332-7ND00-0AB0
7789195xxx
6ES7 332-5RD00-0AB0
7789233xxx
6ES7 332-5HF00-0AB0
7789196xxx
6ES7 334-0KE00-0AB0
7789226xxx
6ES7 335-7HG01-0AB0
7789225xxx
6ES7 334-0CE01-0AA0
6ES7 321-1BH01 / 1BH81-0AA0
6ES7 321-1BL00 / 1BL80-0AA0
6ES7 321-1BP00-0AA0
6ES7 321-1EH01-0AA0
6ES7 321-1BH50-0AA0
6ES7 321-7BH00 / 7BH80-0AB0
6ES7 321-1FF01 / 1FF81-0AA0
6ES7 321-1EL00-0AA0
6ES7 321-1CH80-0AA0
6ES7 321-7RD00-0AB0
6ES7 322-1BH01 / 1BH81-0AA0
6ES7 322-1BL00-0AA0
6ES7 322-1BP00-0AA0
6ES7 321-1BP50-0AA0
6ES7 322-1EH01-0AA0
6ES7 322-1BF01-0AA0
6ES7 322-1FF01 / 1FF81-0AA0
6ES7 322-1HF01-0AA0
Qty
1
1
2
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Order No.
7789293xxx
7789293xxx
Qty
1
2
7789293xxx
1
7789293xxx
7789293xxx
1
2
7789293xxx
2
Digital relay
output
- see page B.39 -
- see page B.42 -
Qty
Type
16-channel - H
32-channel - H
32-channel - H
16-channel - R
16-channel - H
16-channel - R
8-channel - R
32-channel - R
16-channel - R
16-channel - H
Digital optodecoupled input
B)
A, B)
A, B)
1
1
2
1
1
1
1
1
1
1
Qty
Type
16-channel
16-channel
B)
B)
Type
1
8-channel - R
16-channel - R
1
1
16-channel - R
16-channel - R
16-channel - R
8-channel - R
8-channel - H
8-channel - H
8-channel - H
16-channel - H
12-channel - H
16-channel - H
16-channel - H
16-channel - H
8-channel - H
16-channel - H
8-channel - H
16-channel - H
8-channel - H
D)
D)
E)
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Qty
- see page B.54 Type
Qty
8-channel P
1
8-channel P
1
8-channel P
8-channel
16-channel
4-channel
4-channel
8-channel
8-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
4-channel
8-channel
8-channel
16-channel
16-channel
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
)
16-channel
32-channel
32-channel
32-channel
16-channel - R
Analog
input/output
16-channel
1
C)
A, C)
1
1
A, C)
A, C)
8-channel
1
8-channel
1
8-channel
16-channel
8-channel
16-channel
16-channel
16-channel
1
1
1
1
1
1
E)
16-channel
1
16-channel
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example: Cable 2 meters in length: Order number: 7 7 8 9 2 3 6 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
E) Two channels unused
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.6
PLC Siemens - S7-400
PLC
I/O cards
Cables
Standard
Interfaces
Digital Direct
I/Os
SITOP Connection
- see page B.21 -
Anal.
O
Anal. Input
Digital output
Digital input
Manufacturer order number
6ES7 421-1BL00-0AA0
6ES7 421-1EL00-0AA0
6ES7 421-1FH00-0AA0
6ES7 421-7DH00-0AB0
6ES7 421-7BH00-0AB0
6ES7 421-1FH20-0AA0
6ES7 422-1BH10-0AA0
6ES7 422-1BL00-0AA0
6ES7 422-1FF00-0AA0
6ES7 422-1FH00-0AA0
6ES7 422-1HH00-0AA0
6ES7 422-5EH10-0AB0
6ES7 422-7BL00-0AB0
6ES7 431-1KF00-0AB0
6ES7 431-1KF00-0AB0
6ES7 431-1KF10-0AB0
6ES7 431-1KF20-0AB0
6ES7 431-7QH00-0AB0
6ES7 431-0HH00-0AB0
6ES7 432-1HF00-0AB0
Order No.
Qty
7789292xxx
7789278xxx
7789273xxx
7789278xxx
7789290xxx
7789273xxx
7789291xxx
7789292xxx
7789283xxx
7789273xxx
7789270xxx
7789291xxx
7789292xxx
7789287xxx
7789286xxx
7789285xxx
7789285xxx
7789284xxx
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
7789284xxx
7789288xxx
1
1
Order No.
7789293xxx
7789293xxx
Qty
2
Digital relay
output
- see page B.39 -
- see page B.42 -
Qty
Type
32-channel - H
32-channel - R
16-channel - R
32-channel - R
16-channel - H
16-channel - R
Digital optodecoupled input
A, B)
D)
1
1
1
1
1
1
Type
16-channel
2
8-channel - R
16-channel - R
32-channel - R
Qty
B)
Type
Analog
input/output
Qty
- see page B.54 Type
Qty
2
B
16-channel
32-channel
C)
16-channel
C, F)
32-channel
A,C)
C)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
8-channel
8-channel
8-channel
8-channel
16-channel
16-channel
8-channel
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 2 9 2 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
PLC Interfaces
H-, R- and S-System
Selection Guide
B.7
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC Télémécanique - Micro
PLC
I/O cards
Cables
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Digital output Digital input
Manufacturer order number
Anal.
Output
Anal.
Input
Digital
Input/Output
B
TSX DEZ 12D2
TSX DEZ 08A4
TSX DEZ 12D2K
TSX DEZ 08A5
TSX DEZ 32D2
TSX DSZ 04T22
TSX DSZ 08T2
TSX DSZ 08R5
TSX DSZ 08T2K
TSX DSZ 32T2
TSX DSZ 32R5
TSX DMZ 28DT
TSX DMZ 28DR
TSX DMZ 28AR
TSX DMZ 64DTK (*)
TSX DMZ 28DTK
TSX DMZ 16DTK
TSX 37-22 (integrated)
TSX AEZ 801
TSX AEZ 802
TSX AEZ 414
TSX 37-22 (integrated)
TSX ASZ 401
TSX ASZ 200
Order No.
7789312xxx
7789307xxx
7789301xxx
7789307xxx
7789314xxx
7789312xxx
7789312xxx
7789308xxx
7789301xxx
7789314xxx
7789330xxx
7789313xxx
7789331xxx
7789331xxx
7789301xxx
7789301xxx
7789301xxx
7789257xxx
7789311xxx
7789311xxx
7789309xxx
7789257xxx
7789310xxx
7789310xxx
Qty
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
2
1
1
1
1
1
1
1
1
Type
12-channel - H
8-channel - R
12-channel - H
8-channel - R
32-channel - H
16-channel - R
32-channel - R
16-channel - H
16-channel - R
16-channel - R
32-channel - H
16-channel - H
16-channel - H
- see page B.39 Qty
B)
B)
A, B)
D)
D)
B)
D)
D)
A, B)
B)
1
1
1
1
1
Type
Analog
input/output
Digital relay
output
- see page B.42 Qty
16-channel
B, E)
1
16-channel
B, E)
1
16-channel
B)
2
Type
- see page B.54 Qty
8-channel
8-channel
C)
8-channel
32-channel
C)
C)
Type
1
1
1
1
1
2
2
1
1
1
A, C)
1
1
16-channel
B)
1
12-channel
C)
1
16-channel
16-channel
B)
2
1
32-channel
12-channel
A, C)
1
1
B)
C)
9 channels M
8-channel
8-channel
4-channel
9 channels M
4-channel
4-channel
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 3 0 1 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
E) Four channels unused
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.8
Qty
1
1
1
1
1
1
1
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC Télémécanique - Premium
PLC
I/O cards
Cables
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Anal.
Output
Anal. Input
Digital output
Digital input
Manufacturer order number
TSX DEY 08D2
TSX DEY 16D2
TSX DEY 16D3
TSX DEY 16A2 (1)
TSX DEY 16A3
TSX DEY 16A4
TSX DEY 16A5
TSX DEY 16FK (*)
TSX DEY 32D2K (*)
TSX DEY 64D2K (*)
TSX DSY 08T2
TSX DSY 08T22
TSX DSY 16T2
TSX DSY 08T31
TSX DSY 16T3
TSX DSY 08R5
TSX DSY 16R5
TSX DSY 08R5A
TSX DSY 08R4D
TSX DSY 08S5
TSX DSY 16S4
TSX DSY 32T2K (*)
TSX DSY 64T2K (*)
TSX AEY 414
TSX AEY 414
TSX AEY 420
TSX AEY 800
TSX AEY 810
TSX AEY 1600
TSX ASY 410
TSX ASY 410
TSX ASY 800
Order No.
7789322xxx
7789322xxx
7789322xxx
7789315xxx
7789315xxx
7789315xxx
7789315xxx
7789301xxx
7789301xxx
7789301xxx
7789322xxx
7789317xxx
7789322xxx
7789317xxx
7789322xxx
7789316xxx
7789316xxx
7789318xxx
7789318xxx
7789316xxx
7789316xxx
7789301xxx
7789301xxx
7789320xxx
7789319xxx
7789259xxx
7789259xxx
7789261xxx
7789259xxx
7789320xxx
7789321xxx
7789259xxx
Qty
1
1
1
1
1
1
1
1
2
4
1
1
1
1
1
1
1
1
1
1
1
2
4
1
1
1
1
1
2
1
1
1
8-channel - H
16-channel - H
16-channel - H
16-channel - R
16-channel - R
16-channel - R
16-channel - R
16-channel - H
32-channel - H
32-channel - H
- see page B.39 Qty
Type
B)
B, G)
D)
B)
A, B)
A, B)
1
1
1
1
1
1
1
1
1
2
8-channel - R
1
8-channel - R
16-channel - H
16-channel - R
16-channel - R
16-channel - R
16-channel - R
16-channel - R
16-channel - R
1
1
1
1
1
1
1
1
G)
D)
D)
D)
D)
Type
16-channel
16-channel
16-channel
16-channel
16-channel
- see page B.42 Qty
B)
B)
B)
B)
B)
Analog
input/output
Digital relay
output
- see page B.54 Qty
Type
Qty
Type
1
1
1
1
1
1
1
1
2
4
B
8-channel
C)
1
16-channel
C)
1
32-channel
32-channel
A,C)
1
2
A,C)
1
1
1
1
1
2
1
1
1
4-channel
8-channel
8-channel P
8-channel P
8-channel P
8-channel P
4-channel
4-channel
8-channel P
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 3 0 1 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
G) Only use modules without LED
1) Use in ac mode
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.9
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC Télémécanique - Twido
PLC
I/O cards
Cables
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Digital
input
Manufacturer order number
Digital
I/O
Digital output
B
- see page B.39 -
Qty
Type
Qty
8-channel - H
1
1
1
1
1
TWD DDI 8DT
TWD DDI 16DT
TWD DDI 16DK (1)
TWD DDI 32DK (1)
TWD DDO 8UT
TWD DDO 8TT
TWD DDO 16UK
TWD DDO 16TK
TWD DDO 32UK
TWD DDO 32TK
TWD DRA 8RT
TWD DRA 16RT
TWD LMDA 20DTK (1)
TWD LMDA 20DUK (1)
7789100xxx
7789100xxx
7789328xxx
7789328xxx
7789100xxx
7789100xxx
7789328xxx
7789329xxx
7789328xxx
7789329xxx
7789108xxx
7789104xxx
7789327xxx
7789326xxx
1
1
1
2
1
1
1
1
2
2
1
1
1
1
TWD LMDA 20DTR
TWD LMDA 40DUK (1)
7789100xxx
7789104xxx
7789327xxx
7789326xxx
1
1
2
2
TWD AMI 2HT
TWD AMO 1HT
TWD AMM 3HT
TWD ALM 3LT
7789250xxx
7789250xxx
7789250xxx
7789250xxx
1
1
1
1
TWD LMDA 40DTK (1)
Anal. I/O
Order No.
16-channel - H
16-channel - H
32-channel - H
8-channel - H
B)
B)
A, B)
16-channel - H
32-channel - H
8-channel - R
16-channel - R
12-channel - H
12-channel - H
8-channel - H
12-channel - H
16-channel - R
12-channel - H
12-channel - H
8-channel - H
Type
16-channel
16-channel
16-channel
- see page B.42 Qty
B)
B)
B)
Analog
input/output
Digital relay
output
- see page B.54 Qty
Type
Type
1
1
2
8-channel
C)
1
16-channel
C)
1
32-channel
A,C)
1
8-channel
C)
1
8-channel
C)
2
1
A)
D)
B)
B)
B)
D)
B)
1
1
1
1
1
1
1
1
2
2
2
1
1
16-channel
16-channel
B)
16-channel
B)
1
16-channel
B)
2
B)
4-channel
4-channel
4-channel
4-channel
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 1 0 0 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
1) Use in positive logic
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.10
Qty
1
1
1
1
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC Télémécanique - Quantum
PLC
I/O cards
Cables
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Anal.
Output
Anal. Input
Dig.
I/O
Digital output
Digital input
Manufacturer order number
140 DAI 540 00
140 DAI 540 00
140 DAI 553 00
140 DAI 740 00
140 DAI 740 00
140 DAI 340 00
140 DAI 340 00
140 DAI 353 00
140 DAI 440 00
140 DAI 440 00
140 DAI 453 00
140 DDI 841 00
140 DDI 853 00
140 DDI 353 00
140 DDI 364 00
140 DAO 840 00
140 DAO 840 00
140 DAO 842 10
Order No.
140 DDO 353 00
140 DDO 843 00
140 DDO 364 00
140 DRA 840 00
140 DDM 390 00
7789118xxx
7789110xxx
7789118xxx
7789118xxx
7789110xxx
7789118xxx
7789110xxx
7789118xxx
7789118xxx
7789110xxx
7789118xxx
7789119xxx
7789121xxx
7789121xxx
7789301xxx
7789118xxx
7789112xxx
7789113xxx
7789121xxx
7789120xxx
7789301xxx
7789118xxx
7789133xxx
140 ACI 030 00
140 ACI 030 00
140 AVI 030 00
140 AVI 030 00
140 ARI 030 10
140 ACI 040 00
140 AII 330 00
140 ACO 020 00
140 ACO 130 00
140 AIO 330 00
7789125xxx
7789134xxx
7789125xxx
7789134xxx
7789135xxx
7789123xxx
7789136xxx
7789124xxx
7789126xxx
7789137xxx
Qty
1
1
1
1
1
1
1
1
1
1
1
1
1
1
6
1
1
1
1
1
6
1
1
32-channel - R
16-channel - R
32-channel - R
32-channel - R
16-channel - R
32-channel - R
16-channel - R
32-channel - R
32-channel - R
16-channel - R
32-channel - R
16-channel - H
32-channel - H
32-channel - H
32-channel - H
32-channel - R
16-channel - R
16-channel - R
- see page B.39 Qty
Type
D)
D)
B)
A, B)
A, B)
A, B)
D)
D)
D)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
3
1
1
1
Type
- see page B.42 Qty
D)
B)
1
1
- see page B.54 Qty
Type
Qty
Type
B
16-channel
16-channel
16-channel
16-channel
B)
B)
B)
B)
1
2
2
6
32-channel
16-channel
32-channel
32-channel - R
16-channel - H
Analog
input/output
Digital relay
output
16-channel
B)
1
8-channel
A, C)
C, F)
A, C)
C)
1
1
3
1
8-channel
8-channel
8-channel
8-channel
8-channel
16-channel
8-channel
4-channel
8-channel
8-channel
1
1
1
1
1
1
1
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 3 0 1 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.11
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC Télémécanique - M340
PLC
I/O cards
Cables
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Digital input
Manufacturer order number
Anal.
I/O
Anal.
O
Anal.
Input
Digital
I/O
Digital output
B
Order No.
Qty
BMX DDI 1602
BMX DDI 1603
BMX DDI 3202K
BMX DDI 6402K
BMX DAI 1602 (1)
BMX DAI 1602 (2)
BMX DAI 1603
BMX DAI 1604
BMX DAO 1605
BMX DDO 1602
BMX DDO 1612
BMX DDO 3202K
BMX DDO 6402K
BMX DRA 0805
BMX DRA 1605
BMX DDM 16025
7789380xxx
7789382xxx
7789387xxx
7789387xxx
7789630xxx
7789382xxx
7789382xxx
7789382xxx
7789383xxx
7789380xxx
7789380xxx
7789387xxx
7789387xxx
7789633xxx
7789384xxx
7789635xxx
1
1
1
2
1
1
1
1
1
1
1
1
2
1
1
1
BMX DDM 16022
BMX DDM 3202K
BMX AMI 0410 (3)
BMX AMI 0410 (4)
BMX ART 0414
BMX ART 0814
BMX AMO 0210
7789386xxx
7789387xxx
7789637xxx
7789638xxx
7789639xxx
7789639xxx
7789640xxx
1
1
1
1
1
2
1
BMX AMM 0600 (3)
BMX AMM 0600 (4)
7789628xxx
7789629xxx
1
1
16 channels-H
16 channels-R
32 channels-H
32 channels-H
16 channels-H
16 channels-R
16 channels-R
16 channels-R
16 channels-R
- see page B.39 Qty
Type
(B)
(A) (B)
(A) (B)
(B)
(D) (K)
1
1
1
2
1
1
1
1
1
Type
- see page B.42 Qty
16 channels-H
(B)
1
16 channels-H
16 channels-H
16 channels-H
(B)
2
4
1
(B)
(B)
(D)
(D)
(D)
- see page B.54 Qty
Type
16 channels
16 channels
16 channels
16 channels
16 channels-R
16 channels-R
8 channels-H
8 channels-R
8 channels-H
16 channels-H
Analog
input/output
Digital relay
output
(C)
(C)
(C)
(C)
Type
1
1
2
4
1
1
1
1
2
2
4 channels
4 channels
16 channels
16 channels
4 channels
4 channels
4 channels
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 2 3 6 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
K) Each interface have one common
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
(1) use in 24 VDC, negative logic
(2) use in 24 VAC
(3) Use this cable for voltage signals.
(4) Use this cable for current signals.
B.12
Qty
1
1
1
2
1
1
1
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC Rockwell - SLC 500
PLC
I/O cards
Cables
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Anal. Anal. Anal.
O
I
I/O
Digital output
Digital input
Manufacturer order number
1746 - IB32
1746 - IV32
1746 - IB16
1746 - IC16
1746 - IN16
1746 - ITB16
1746 - ITV16
1746 - IV16
1746 - IB8
1746 - IV8
1746 - OB32
1746 - OV32
1746 - OB16
1746 - OB16E
1746 - OBP16
1746 - OG16
1746 - OV16
1746 - OVP16
1746 - OW16
1746 - OB8
1746 - OBP8
1746 - OV8
1746 - OW8
1746 - OX8
1746 - OW4
1746 - NI8
1746 - NI4
1746 - NO4V
1746 - NO4I
1746 - NIO4V
1746 - NIO4I
Order No.
7789005xxx
7789670xxx
7789001xxx
7789001xxx
7789001xxx
7789001xxx
7789000xxx
7789000xxx
7789100xxx
7789100xxx
7789006xxx
7789006xxx
7789003xxx
7789003xxx
7789003xxx
7789003xxx
7789003xxx
7789003xxx
7789002xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
7789100xxx
7789011xxx
7789008xxx
7789010xxx
7789010xxx
7789009xxx
7789009xxx
Qty
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
32-channel - H
32-channel - H
16-channel - H
16-channel - H
16-channel - H
16-channel - H
16-channel - H
16-channel - H
8-channel - H
8-channel - H
A, B)
32-channel - H
A)
A)
16-channel - H
16-channel - H
16-channel - H
1
1
1
1
1
1
1
1
1
1
Type
16-channel
- see page B.42 Qty
B)
- see page B.54 Qty
Type
Type
Qty
2
B
32-channel
A, C)
1
16-channel
16-channel
16-channel
C)
1
1
1
16-channel
8-channel
8-channel
C, F)
8-channel
C, F)
1
8-channel
C, F)
1
1
C)
C)
1
1
1
8-channel - H
16-channel - H
- see page B.39 Qty
Type
Analog
input/output
Digital relay
output
C)
C)
1
1
1
1
F)
1
8-channel
4-channel
4-channel
4-channel
4-channel
4-channel
1
1
1
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 0 0 5 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.13
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC Rockwell - Compact Logix
PLC
I/O cards
Cables
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Digital input
Manufacturer order number
Anal.
Input
Dig.
I/O
Digital output
B
Qty
1769 - IA8I
1769 - IM12
1769 - IA16
1769 - IQ16
1769 - IQ16F
1769 - IQ32
1769 - OA8
1769 - OB8
1769 - OW8
1769 - OW8I
1769 - OA16
1769 - OB16
1769 - OB16P
1769 - OV16
1769 - OW16
1769 - OB32
1769 - IQ6XOW4
7789016xxx
7789025xxx
7789025xxx
7789019xxx
7789019xxx
7789019xxx
7789017xxx
7789015xxx
7789017xxx
7789016xxx
7789024xxx
7789018xxx
7789018xxx
7789018xxx
7789024xxx
7789018xxx
7789014xxx
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
2
1
1769 - IF4
7789026xxx
7789046xxx
7789027xxx
7789047xxx
7789028xxx
7789045xxx
7789029xxx
7789043xxx
7789044xxx
7789044xxx
1
1
1
1
1
1
1
1
1
1
1769 - IF4I
1769 - IF8
Anal.
Output
Order No.
1769 - OF2
1769 - OF4CI
1769 - OF8V
1769 - OF8C
Type
- see page B.39 Qty
16-channel - R
16-channel - R
16-channel - R
16-channel - H
16-channel - H
16-channel - H
8-channel - R
1
1
1
1
1
2
1
8-channel - R
16-channel - R
16-channel - R
1
1
1
16-channel - H
16-channel - R
1
1
16-channel - R
1
Type
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 0 1 9 0 2 0
Notes concerning the use of interface modules:
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.14
Analog
input/output
Digital relay
output
- see page B.42 Qty
- see page B.54 Qty
Type
8-channel
C)
1
16-channel
16-channel
C)
1
1
16-channel
C)
C)
Type
Qty
2
4-channel
4-channel
4-channel
4-channel
8-channel
8-channel
4-channel
4-channel
8-channel
8-channel
1
1
1
1
1
1
1
1
1
1
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC Rockwell - Control Logix
PLC
I/O cards
Cables
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Anal.
O
Anal.
I
Digital output
Digital input
Manufacturer order number
1756-IA16
1756-IA16I
1756-IA8D
1756 - IB16
1756-IB16D
1756-IB16I
1756-IB32
1756 - IC16
1756-IH16I
1756-IM16I
1756 - IN16
1756 - OA16
1756-OA16I
1756 - OA8
1756-OA8D
1756-OA8E
1756-OB16D
1756 - OB16E
1756-OB16I
1756 - OB32
1756 - OB8
1756-OB8EI
1756-OC8
1756-OH8I
1756-ON8
1756-OW16I
1756-OX8I
1756-IF6I
1756-IF6I
1756-IF16
1756 - IF8
1756 - IF8
1756-IR6I
1756-OF4
1756-OF4
1756-OF6VI
1756-OF6CI
1756-OF8
1756-OF8
1756-OV16E
Order No.
7789031xxx
7789030xxx
7789048xxx
7789039xxx
7789049xxx
7789049xxx
7789041xxx
7789031xxx
7789030xxx
7789030xxx
7789031xxx
7789056xxx
7789030xxx
7789057xxx
7789048xxx
7789048xxx
7789040xxx
7789058xxx
7789059xxx
7789042xxx
7789151xxx
7789152xxx
7789153xxx
7789154xxx
7789057xxx
7789030xxx
7789155xxx
7789156xxx
7789157xxx
7789032xxx
7789035xxx
7789036xxx
7789158xxx
7789033xxx
7789034xxx
7789157xxx
7789159xxx
7789037xxx
7789038xxx
7789165xxx
Qty
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
16-channel - R
32-channel - R
8-channel - R
16-channel - H
16-channel - H
16-channel - H
32-channel - H
16-channel - R
32-channel - R
32-channel - R
16-channel - R
16-channel - R
32-channel - R
8-channel - R
8-channel - R
8-channel - R
- see page B.39 Qty
Type
B)
B)
B)
A, B)
D)
D)
D)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Type
16-channel
16-channel
16-channel
16-channel
- see page B.42 Qty
B)
B)
B)
B)
D)
D)
- see page B.54 Qty
Type
Qty
Type
1
1
1
2
B
16-channel
16-channel
16-channel
32-channel
8-channel
8-channel
16-channel - R
16-channel - R
8-channel - R
32-channel - R
16-channel - R
Analog
input/output
Digital relay
output
C)
C)
C)
A, C)
C)
C)
1
1
1
1
1
1
1
1
1
1
1
8-channel
8-channel
16-channel
8-channel
8-channel
8-channel
4-channel
4-channel
8-channel
8-channel
8-channel
8-channel
16-channel
1
1
1
1
1
1
1
1
1
1
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 0 3 1 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.15
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC Fanuc 90-30 and Alspa 8035
Cables
PLC
I/O cards
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Digital input
Manufacturer order number
Anal Anal Anal. In. I/O . O
put
Digital output
B
IC693MDL230
IC693MDL231
IC693MDL240
IC693MDL241
IC693MDL630
IC693MDL632
IC693MDL634
IC693MDL640
IC693MDL643
IC693MDL645
IC693MDL646
IC693MDL654
IC693MDL655
IC693MDL310
IC693MDL340
IC693MDL730
IC693MDL731
IC693MDL732
IC693MDL733
IC693MDL740
IC693MDL741
IC693MDL742
IC693MDL752
IC693MDL753
IC693ALG220
IC693ALG221
IC693ALG222
IC693ALG223
IC693ALG390
IC693ALG391
IC693ALG442
Order No.
7789064xxx
7789064xxx
7789061xxx
7789067xxx
7789067xxx
7789634xxx
7789067xxx
7789067xxx
7789067xxx
7789067xxx
7789067xxx
7789066xxx
7789066xxx
7789063xxx
7789063xxx
7789069xxx
7789069xxx
7789068xxx
7789068xxx
7789068xxx
7789068xxx
7789068xxx
7789066xxx
7789066xxx
7789076xxx
7789075xxx
7789072xxx
7789072xxx
7789073xxx
7789073xxx
7789074xxx
Qty
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
1
16-channel - R
16-channel - R
16-channel - R
16-channel - H
8-channel - H
8-channel - R
8-channel - H
16-channel - H
16-channel - H
16-channel - H
16-channel - H
32-channel - H
32-channel - H
16-channel - R
16-channel - R
- see page B.39 Qty
Type
D)
B, H)
H)
B)
B)
B, H)
B, H)
A, B, H)
A, B, H)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
8-channel - H
1
8-channel - H
1
16-channel - H
1
32-channel - H
A)
Type
- see page B.42 Qty
16-channel
B, H)
1
16-channel
16-channel
16-channel
16-channel
16-channel
16-channel
B)
1
1
1
1
2
2
B)
B, H)
B, H)
B, H)
B, H)
Analog
input/output
Digital relay
output
- see page B.54 Qty
Type
8-channel
C, F)
1
8-channel
C, F)
1
16-channel
C, F)
1
16-channel
C, F)
1
32-channel
A, C)
1
Type
1
4-channel
4-channel
8-channel
8-channel
8-channel
8-channel
16-channel
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 0 6 7 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)
H) Use the PLC I/O card in positive logic only
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.16
Qty
1
1
1
1
1
1
1
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC Fanuc RX3i
PLC
Cables
I/O cards
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Anal. Output
Anal. Input
Digital output
Digital input
Manufacturer order number
IC694MDL230
IC694MDL231
IC694MDL240
IC694MDL241
IC694MDL250
IC694MDL260 (1)
IC694MDL632 (1)
IC694MDL634
IC694MDL645
IC694MDL646
IC694MDL654 (1)
IC694MDL655 (1)
IC694MDL660
IC694MDL310
IC694MDL330 (1)
IC694MDL340
IC694MDL350
IC694MDL390
IC694MDL732
IC694MDL734
IC694MDL740 (1)
IC694MDL741 (1)
IC694MDL742 (1)
IC694MDL752 (1)
IC694MDL753 (1)
IC694MDL754 (1)
IC694MDL930
IC694MDL931
IC694MDL940 (1)
IC694ALG220
IC694ALG221
IC694ALG222 (2)
IC694ALG223
IC695ALG600 (4)
IC695ALG600 (5) (6)
IC695ALG608
IC695ALG616
IC694ALG390
IC694ALG391
IC694ALG392 (6)
IC694ALG392 (5)
IC695ALG704
IC695ALG708
IC695ALG808
- see page B.39 -
Qty
Type
Qty
7789064xxx
7789064xxx
7789061xxx
7789067xxx
7789631xxx
7789632xxx
7789634xxx
7789067xxx
7789067xxx
7789067xxx
7789066xxx
7789066xxx
7789619xxx
7789063xxx
7789634xxx
7789063xxx
7789631xxx
7789636xxx
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
1
16-channel - R D)
16-channel - R D)
16-channel - R D)
16-channel - H B, H)
32-channel - R D)
32-channel - R D)
8-channel - R D)
8-channel - H H)
16-channel - H B, H)
16-channel - H B, H)
32-channel - H B, H)
32-channel - H B, H)
32-channel - H B, H)
16-channel - R D)
8-channel - R D)
16-channel - R D)
32-channel - R D)
16-channel - R D)
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
7789068xxx
7789669xxx
7789068xxx
7789068xxx
7789068xxx
7789066xxx
7789066xxx
7789618xxx
7789064xxx
7789665xxx
7789666xxx
7789076xxx
7789075xxx
7789072xxx
7789072xxx
7789622xxx
7789623xxx
7789667xxx
7789626xxx
7789073xxx
7789073xxx
7789620xxx
7789624xxx
7789668xxx
7789625xxx
7789621xxx
1
1
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
16-channel - R D)
1
16-channel - H
1
32-channel - H A)
1
Order No.
16-channel - R D)
32-channel - R D)
16-channel - R D)
Analog
input/output
Digital relay
output
- see page B.42 -
Type
Qty
16-channel B, H)
1
Type
- see page B.54 Qty
Qty
Type
B
16-channel B, H)
16-channel B, H)
16-channel B, H)
16-channel B, H)
16-channel B, H)
1
1
2
2
2
8-channel C, F)
1
16-channel C, F)
1
16-channel C, F)
1
32-channel - H A, C)
32-channel - H A, C)
1
1
1
1
1
4-channel
4-channel
8-channel
8-channel
16-channel
16-channel
8-channel
16-channel
8-channel
8-channel
4-channel
4-channel
4-channel
8-channel
8-channel
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 0 6 7 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
F) Operate the PLC output card with 24 V dc only (this corresponds to the operating voltage of the relay coil)
H) Use the PLC I/O card in positive logic only
K) Each interface have one common
(1) All the groups with same common
(2) Single Ended mode applications
(3) Differential Ended applications
(4) RTD or resistance applications
(5) Voltage applications
(6) Current applications
B.17
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC OMRON CQM1
PLC
I/O cards
Cables
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Digital input
Manufacturer order number
Anal.
O
Anal. I
Digital output
B
Order No.
Qty
ID211
ID212
ID213
IA121
IA221
OC221
OC222
OD211
OD212
OD213
OD214
OA221
AD041
7789646xxx
7789647xxx
7789370xxx
7789652xxx
7789652xxx
7789653xxx
7789654xxx
7789653xxx
7789655xxx
7789372xxx
7789655xxx
7789656xxx
7789252xxx
1
1
1
1
1
1
1
1
1
1
1
1
1
DA021
7789251xxx
1
Type
- see page B.39 Qty
16-channel - H
16-channel - H B), H)
32-channel - H B, H)
8-channel - R
8-channel - R
8-channel - R
16-channel - R
8-channel - H
16-channel - H
1
1
1
1
1
1
1
1
1
Type
16-channel
16-channel
- see page B.42 Qty
B, H)
B, H)
1
1
1
1
- see page B.54 Qty
Type
Qty
Type
1
2
32-channel
16-channel
8-channel - R
Analog
input/output
Digital relay
output
A, C)
C)
1
1
8-channel
J)
1
4-channel
J)
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 1 4 3 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
H) Only for positive logic, for negative logic invert the polarity of the source on the interface.
J) The PLC connector is not included. The wires of the cable are free and equipped with ferrules.
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.18
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC OMRON C200H
PLC
I/O cards
Cables
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Digital output
Digital input
Manufacturer order number
ID211
ID001
ID002
IA121
IA122
IM211
ID212
IA122-V
IA222-V
IM212
ID216
ID217
OC221
OC224-V
OC223
OD214
OD411
OD213
OA221
OC222-V
OD217
OD211
OA222-V
OC225
OD212
Order No.
7789100xxx
7789100xxx
7789100xxx
7789108xxx
7789104xxx
7789108xxx
7789100xxx
7789104xxx
7789104xxx
7789100xxx
7789370xxx
7789370xxx
7789108xxx
7789104xxx
7789108xxx
7789100xxx
7789100xxx
7789100xxx
7789108xxx
7789104xxx
7789100xxx
7789100xxx
7789104xxx
7789104xxx
7789100xxx
Qty
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
Type
8-channel - H J)
8-channel - H J)
8-channel - H J)
8-channel - R J)
16-channel - R J)
8-channel - H J)
16-channel - H B, J)
16-channel - R J)
16-channel - R J)
16-channel - H B, J)
32-channel - H A, B, H)
32-channel - H A, B, H)
8-channel - R J)
16-channel - R J)
8-channel - R J)
8-channel - H J)
8-channel - H J)
8-channel - R J)
16-channel - R J)
12-channel - H J)
16-channel - R J)
16-channel - R J)
16-channel - H J)
- see page B.39 Qty
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
Type
Analog
input/output
Digital relay
output
- see page B.42 Qty
- see page B.54 Qty
Type
Qty
Type
B
16-channel
B, J)
1
16-channel
16-channel
16-channel
B, J)
1
2
4
B)
B)
8-channel
C, J)
1
12-channel
C, J)
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 1 4 2 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
H) Only for positive logic, for negative logic invert the polarity of the source on the interface.
J) The PLC connector is not included. The wires of the cable are free and equipped with forks.
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.19
PLC Interfaces
H-, R- and S-System
Selection Guide
PLC OMRON CJ1W
PLC
I/O cards
Cables
Interfaces
Digital direct
input/output
Standard
Digital optodecoupled input
- see page B.21 -
Digital input
Manufacturer order number
Digital output
B
ID211
ID231
ID232
ID261
ID262
IA111
IA201
OC201
OC211
OD201
OD202
OD211
OD212
OD231
OD232
OD233
OD261
OD263
OA201
Order No.
7789645xxx
7789370xxx
7789371xxx
7789370xxx
7789371xxx
7789664xxx
7789648xxx
7789649xxx
7789664xxx
7789650xxx
7789650xxx
7789651xxx
7789651xxx
7789372xxx
7789373xxx
7789373xxx
7789372xxx
7789373xxx
7789648xxx
Qty
1
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
2
2
1
Type
- see page B.39 Qty
16-channel - H B, H)
32-channel - H A, B, H)
32-channel - H A, B, H)
32-channel - H A, B, H)
32-channel - H A, B, H)
16-channel - R
8-channel - R
16-channel - R
16-channel - R
8-channel - H
1
1
1
2
2
1
1
1
1
1
Type
16-channel
16-channel
16-channel
16-channel
16-channel
- see page B.42 Qty
B)
B)
B)
B)
B)
- see page B.54 Qty
Type
Type
1
2
2
4
4
8-channel
16-channel
16-channel
32-channel
32-channel
32-channel - H A)
32-channel - H A)
32-channel - H A)
8-channel - R
Analog
input/output
Digital relay
output
C)
C)
C)
A, C)
A, C)
1
1
1
1
1
1
2
2
1
Notes concerning cable lengths:
The suffix xxx of the “Order number” shows the length of the cable in dm.
The standard lengths are: 1.00 m (010) - 1.50 m (015) - 2.00 m (020) - 3.00 m (030) - 5.00 m (050)
Example:
Cable 2 meters in length: Order number: 7 7 8 9 1 0 0 0 2 0
Notes concerning the use of interface modules:
A) 32-channel modules equipped with 2 HE 10 connectors (H-system) can always be replaced with 2 x 16-channel modules
B) For the inputs, it is possible to use either a digital direct input/output module or an opto-decoupled input module
C) For the outputs, it is possible to replace the relay output modules with digital direct input/output modules
D) The rated voltage for the I/O card used must be taken into consideration when selecting a digital input/output module for the R-system. If the voltage exceeds 160 V, the following modules only can be used:
- 8-channel: 944154 (RS8ES-DP RSV1.6/V), 16-channel: 944186 (RS16ES-I RSV1.6/V), 32-channel: 944187 (RS32ES-I RSV1.6/V)
H) Only for positive logic, for negative logic invert the polarity of the source on the interface.
*
All I/O signals with same common.
*
Additional technical information about pre-assembled cable available in ON-line catalog http://www.weidmuller.com
B.20
Qty
Type
No. of
channels
8
channels
12
chan.
Functionalities
Compact
version
Connection
H or R
System
Type of
wiring
H System
2-wire
V
R System
2-wire
V
H System
2-wire
V
C
C
Screw
V
V
1-wire
C
C
H System
2-wire
16
channels
3-wire
C
C
C
V
V
V
V
V
V
V
V
V
1-wire
R System
V
V
V
2-wire
3-wire
C
C
V
V
1-wire
C
V
V
H System
2-wire
32
channels
3-wire
1-wire
R System
2-wire
3-wire
C
C
C
V
V
V
V
V
V
V
V
V
Tension c.
1 LED
per chan.
Modules
Disconnectable
Fuse
L
Z
Z
Z
L
L
L
L
L
L
L
I
I
I
L
L
I
Z
Z
Z
F
L
L
L
L
L
L
L
I
I
I
L
L
Note: Preferred articles in bold
I
I
F
B.22
B.22
9445630000
RS 12ES-D-L H/V
B.23
9445700000
RS 16ES H/V
B.24
9445710000
RS 16ES-L H/V
B.24
9447700000 (*) RS 16ES H/Z
B.24
9447710000
RS 16ES-L H/Z
B.24
9445810000
RS 16ES-S-I-L H/V
B.24
9445720000
RS 16ES-D H/V
B.25
9445730000
RS 16ES-D-L H/V
B.25
9447730000
RS 16ES-D-L H/Z
B.25
9445750000
RS 16ES-D-I-L H/V
B.25
RS 16ES-D-I-L H/Z
B.25
9445820000
RS 16ES-D-F H/V
B.26
9445760000
RS 16ES-T H/V
B.26
9445770000
RS 16ES-T-L H/V
B.26
9447770000
RS 16ES-T-L H/Z
B.26
9441500000
RS16ES RSV1,6/V
B.27
9441860000
RS16ES-I RSV1,6/V
B.27
9441700000
RS16ES-DP RSV1,6/V
B.28
9441560000
RS16ES-DP/F RSV1,6/V
B.28
(*)
9441600000 (*) RS16E-3E/I RSV1,6/V
B.29
9445900000
RS 32ES H/V
B.30
9445910000
RS 32ES-L H/V
B.30
9447900000 (*) RS 32ES H/Z
B.30
9447910000
RS 32ES-L H/Z
B.30
9445870000
RS 32ES-S-I-L H/V
B.31
9445930000
RS 32ES-D-L H/V
B.32
9447930000
RS 32ES-D-L H/Z
B.32
9445950000
RS 32ES-D-I-L H/V
B.33
9447950000
F
RS 8ES-D-L H/V
Page
9441540000 (*) RS8ES-DP RSV1,6/V
9447750000
F
I
Z
Z
Type
9445530000
L
Z
Z
Order No.
RS 32ES-D-I-L H/Z
B.33
9445980000
RS 32ES-D-F H/V
B.34
9445960000
RS 32ES-T H/V
B.35
9445970000
RS 32ES-T-L H/V
B.35
9447970000
RS 32ES-T-L H/Z
B.35
9441510000
RS32ES RSV1,6/V
B.36
9441870000
RS32ES-I RSV1,6/V
B.36
9441710000
RS32ES-DP RSV1,6/V
B.37
9441570000
9441610000
(*)
(*)
RS32ES-DP/F RSV1,6/V
B.37
RS32E-3E/I RSV1,6/V
B.38
(*) Available upon customer request
B.21
PLC Interfaces
H-, R- and S-System
Module Overview - Direct Inputs/Outputs for Digital Cards
B
RS ES-D - 8-channel
RS ES-DP - 8-channel
H-System – 2-wire (common + or –)
Version: screw connection
R-System – 2-wire (common + or –)
Version: screw connection
Dimensions
B
0.0
1
0.1
2
0.2
3
0.3
4
0.7
8
C
I/O PCB Connector
C
C
C
A
-
-
C
+
C
+
Connector HE10/20 poles
C
Shunt
B
For 8-channel digital I/O cards
H System and R System
Supply Voltage
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
18
20
FUS
+F
17
19
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
RSV 1.6 connector – 12 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
24 V DC ± 10%
1 A (*)
3A
–
–
Green
+ or – selectable with a jumper
3A
24 V DC / LED yellow
2A
3.15 A
250 V max
1 A (*)
3A
–
–
–
+ or – selectable with a jumper
3A
max 250 V
2A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
250 V AC
III
2
1.7 KV DC
-25…50 ºC
-40…60 ºC
74 x 87.5 x 72
68 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
Type
Order No.
Type
RS8ES-DP RSV1,6/V
RS 8ES-D-L H/V
9445530000
Ordering data
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
B.22
(1) Available upon customer request
Order No.
9441540000 (1)
For 12-channel digital I/O cards
System H
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
RS ES-D - 12-channel
H-System – 2-wire (common + or –)
Version: screw connection
B
Dimensions
B
0.0
1
0.1
2
C
C
0.2
3
0.3
4
1.3
12
-
18
20
C
A
Shunt
Supply Voltage
C
C
+
C
+
FUS
+F
Connector HE10/20 poles
I/O PCB Connector
C
17
19
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
24 V DC ± 10%
1 A (*)
3A
–
–
Green
+ or – selectable with a jumper
3A
24 V DC / LED yellow
2A
3.15 A
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
mm
Note
95 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Ordering data
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Type
Order No.
RS 12ES-D-L H/V
9445630000
Note
B.23
RS ES-S - 16-channel
RS ES-S-I - 16 disconnectable channels
C
Dimensions
B
Disconnectable
connector
1
0.0
1
0.0
2
0.1
+
18
20
17
19
FUS
+F
I/O PCB Connector
3
0.2
4
0.3
1.7
16
-
18
20
+
FUS
+F
Connector HE10/20 poles
16
Connector HE10/20 poles
4
0.3
1.7
A
2
0.1
3
0.2
Supply Voltage
C
I/O PCB Connector
B
For 16-channel digital I/O cards
System H
Supply Voltage
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
17
19
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3A
–
–
Green (versions with LED)
–
–
24 V DC / LED yellow
2A
3.15 A
24 V DC ± 10%
1 A (*)
3A
–
Yes - each channel
Green
–
–
24 V DC / LED yellow
2A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
81 x 87.5 x 72
110 x 87.5 x72
(*) Observe the max. permissible current for the common wires
(*) Observe the max. permissible current for the common wires
Type
RS 16ES H/V C
RS 16ES-L H/V C
RS 16ES H/Z
RS 16ES-L H/Z
Type
RS 16ES-S-I-L H/V
Ordering data
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
C : compact version
(1) Available upon customer request
B.24
C
C
Order No.
9445700000
9445710000
9447700000 (1)
9447710000
Order No.
9445810000
For 16-channel digital I/O cards
System H
RS ES-D - 16-channel
RS ES-D-I - 16 disconnectable channels
H-System – 2-wire (common + or –)
Versions: screw / tension clamp connection - compact
H-System – 2-wire (common + or –)
Versions: screw / tension clamp connection - compact
C
C
B
Dimensions
B
Disconnectable
connector
0.1
2
C
0.2
3
C
0.3
4
-
+
C
+
18
20
17
19
FUS
+F
1
0.1
2
0.2
3
0.3
4
1.7
16
-
18
20
C
Supply Voltage
Shunt
Supply Voltage
A
C
0.0
C
Shunt
16
1.7
C
Connector HE10/20 poles
C
I/O PCB Connector
C
I/O PCB Connector
C
C
+
C
+
Connector HE10/20 poles
0.0
1
C
17
19
FUS
+F
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3A
–
–
Green (versions with LED)
+ or – selectable with a jumper
3A
24 V DC / LED yellow
2A
3.15 A
24 V DC ± 10%
1 A (*)
3A
–
Yes - each channel
Green
+ or – selectable with a jumper
3A
24 V DC / LED yellow
2A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
117 x 87.5 x 72
119 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
(*) Observe the max. permissible current for the common wires
Type
RS 16ES-D H/V C
RS 16ES-D-L H/V C
Order No.
9445720000
9445730000
Type
9447730000
RS 16ES-D-I-L H/Z
Ordering data
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
RS 16ES-D-L H/Z
C : compact version
C
C
RS 16ES-D-I-L H/V C
Order No.
C
9445750000
9447750000 (1)
C : compact version
(1) Available upon customer request
B.25
RS ES-D-F - 16-channel with fuse
RS ES-T - 16-channel
H-System – 2-wire (common + or –)
Version: screw connection
H System – 3-wire (common + and –)
Versions: screw / tension clamp connection - compact
C
Dimensions
B
0.0
FUS
1
0.1
FUS
2
0.2
FUS
3
-
1.7
FUS
16
-
-
C
+
C
+
18
20
FUS
+F
17
19
I/O PCB Connector
4
0.1
2
0.2
3
0.3
4
1.7
16
+
+
+
Supply Voltage
FUS
Connector HE10/20 poles
0.3
C
A
-
C
C
1
-
Connector HE10/20 poles
I/O PCB Connector
C
0.0
+
C
Shunt
B
For 16-channel digital I/O cards
System H
Supply Voltage
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
18
20
+
+
17
19
FUS
+F
+F
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
mm
Note
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
≤ 25V AC 50 V DC
1 A (*)
3A
0.5 A fuse on each channel
–
–
+ or – selectable with a jumper
3A
24 V DC / LED yellow
2A
3.15 A
≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3A
–
–
Green (versions with LED)
+ and –
3A
24 V DC / LED yellow
2A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
122 x 87.5 x 72
110 x 87.5 x72
(*) Observe the max. permissible current for the common wires
(*) Observe the max. permissible current for the common wires
Type
RS 16ES-D-F H/V
Type
RS 16ES-T H/V
RS 16ES-T-L H/V
Ordering data
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
B.26
Order No.
9445820000
RS 16ES-T-L H/Z
C : compact version
C
C
Order No.
9445760000
9445770000
9447770000
For 16-channel digital I/O cards
System R
RS ES - 16-channel
RS ES-I – 16 disconnectable channels
System R – 1-wire cabling
Version: screw connection
System R – 1-wire cabling
Version: screw connection
B
Dimensions
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
mm
Note
RSV 1.6 connector - 24 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
RSV 1.6 connector - 24 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
max 150 V UC
1 A (*)
3A
–
–
–
–
–
max 150 V
2A
–
250 V max
1 A (*)
3A
–
Yes - each channel
–
–
–
max 250 V
2A
3.15 A
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
250 V AC
III
2
1.7 KV DC
-25…50 ºC
-40…60 ºC
97 x 87.5 x 68
127 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
Type
RS16ES RSV1,6/V
Type
RS16ES-I RSV1,6/V
Ordering data
Screw connection without LED
Screw connection with LED
Order No.
9441500000
Order No.
9441860000
Note
B.27
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
B
For 16-channel digital I/O cards
System R
RS ES-DP - 16-channel
RS ES-DP/F - 16-channel with fuse
R-System – 2-wire (common + or –)
Version: screw connection
R-System – 2-wire (common + or –)
Version: screw connection
RSV 1.6 connector - 24 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
RSV 1.6 connector - 24 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3A
–
–
–
+ or – selectable with a jumper
3A
max 150 V UC
2A
3.15 A
max 150 V UC
1 A (*)
3A
1 A fuse on each channel
–
–
+ or – selectable with a jumper
3A
max 150 V UC
2A
3.15 A
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
123 x 87.5 x 72
123 x 109 x 72
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
Type
RS16ES-DP RSV1,6/V
Type
RS16ES-DP/F RSV1,6/V
Dimensions
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
mm
Note
Ordering data
Screw connection without LED
Screw connection with LED
Note
B.28
Order No.
9441700000
Order No.
9441560000
For 16-channel digital I/O cards
System R
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
RS ES-3 E/I - 16 disconnectable channels
R System – 3-wire (common + and –)
Version: screw connection
B
Dimensions
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
RSV 1.6 connector - 24 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3A
–
Yes - each channel
–
+ and –
3A
max 150 V UC
3.15 A
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
mm
Note
116 x 109 x 84
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
Ordering data
Screw connection without LED
Screw connection with LED
Note
Type
RS16E-3E/I RSV1,6/V
Order No.
9441600000 (1)
(1) Available upon customer request
B.29
RS ES-S - 32-channel
RS ES-S - 32-channel
H System – 1-wire
Version: screw connection - compact
H System – 1-wire
Version: tension clamp
C
-
18
20
+
17
19
FUS
+F
1
2.1
2
3.7
16
18
20
17
19
0.0
1
0.1
2
1.7
16
-
18
20
+
FUS
+F
17
19
2.0
1
2.1
2
3.7
16
+
18
20
FUS
+F
Connector (2) HE10/20 poles
2.0
Supply Voltage 1
16
I/O PCB Connector
1.7
Supply Voltage 2
I/O PCB Connector
0.1
2
Connector (2) HE10/20 poles
A
1
Connector (1) HE10/20 poles
C
0.0
Connector (1) HE10/20 poles
B
I/O PCB Connector
Dimensions
Supply Voltage
B
For 32-channel digital I/O cards
System H
I/O PCB Connector
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
17
19
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
Length A x width B x height C
C version mm
mm
Note
2 x HE 10 connectors - 20 pole
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
–
24 V DC / LED yellow
2A
3.15 A
≤ 25V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3A
–
–
Green (version with LED)
–
–
2 x 24 V DC / LED yellow (for each 16-channel block)
2A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
≤ 25V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3A
–
–
Green (version with LED)
–
90 x 87.5 x 72
145 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
(*) Observe the max. permissible current for the common wires
Type
RS 32ES H/V
RS 32ES-L H/V
Type
Order No.
RS 32ES H/Z
RS 32ES-L H/Z
9447900000 (1)
9447910000
Ordering data
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
B.30
C : compact version
C
C
Order No.
9445900000
9445910000
(1) Available upon customer request
For 32-channel digital I/O cards
System H
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
RS ES-S-I - 32 disconnectable channels
H System – 1-wire
Version: screw connecion
B
Dimensions
1
B
Supply Voltage 2
A
Disconnectable
connector
16
1.7
-
18
20
+
17
19
FUS
+F
2.0
1
2.1
2
3.7
16
+
18
20
FUS
+F
17
19
Connector (2) HE10/20 poles
I/O PCB Connector
Supply Voltage 1
C
2
0.1
Connector (1) HE10/20 poles
I/O PCB Connector
0.0
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
24 V DC ± 10%
1 A (*)
3A
–
Yes - each channel
Green
–
–
24 V DC / LED yellow
2A
3.15 A
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
mm
Note
220 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Ordering data
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Type
Order No.
RS 32ES-S-I-L H/V
9445870000
Note
B.31
RS ES-D - 32-channel
RS ES-D - 32-channel
H-System – 2-wire (common + or –)
Version: screw connection - compact
H-System – 2-wire (common + or –)
Version: tension clamp
C
18
20
Shunt
C
+
C
+
17
19
FUS
+F
2.1
2
3.7
16
C
A
C
C
18
20
17
19
1.7
16
-
18
20
C
+
C
+
17
19
FUS
+F
2.0
1
2.1
2
3.7
16
C
C
C
-
-
C
+
C
+
18
20
17
19
FUS
+F
Connector (2) HE10/20 poles
1
Connector (2) HE10/20 poles
2.0
Shunt
-
-
2
C
Supply Voltage 1
16
I/O PCB Connector
1.7
C
1
C
Shunt
2
Supply Voltage 2
I/O PCB Connector
C
0.1
C
0.0
0.1
C
Connector (1) HE10/20 poles
1
0.0
C
Connector (1) HE10/20 poles
B
I/O PCB Connector
Dimensions
Supply Voltage
B
For 32-channel digital I/O cards
System H
I/O PCB Connector
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
Length A x width B x height C
C version mm
mm
Note
2 x HE 10 connectors - 20 pole
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
3A
24 V DC / LED yellow
2A
3.15 A
24 V DC ± 10%
1 A (*)
3A
–
–
Green
+ or – selectable with a jumper
3A
2 x 24 V DC / LED yellow (for each 16-channel block)
2A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
24 V DC ± 10%
1 A (*)
3A
–
–
Green
+ or – selectable with a jumper
170 x 87.5 x 72
230 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
(*) Observe the max. permissible current for the common wires
Type
Type
Order No.
RS 32ES-D-L D/Z
9447930000
Ordering data
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
B.32
RS 32ES-D-L H/V
C : compact version
Order No.
C
9445930000
For 32-channel digital I/O cards
System H
RS ES-D-I - 32 disconnectable channels
RS ES-D-I - 32 disconnectable channels
H-System – 2-wire (common + or –)
Version: screw connection - compact
H-System – 2-wire (common + or –)
Version: tension clamp
C
Dimensions
B
Disconnectable
connector
-
18
20
Shunt
C
+
C
+
17
19
FUS
+F
1
2.1
2
I/O PCB Connector
A
C
16
3.7
C
18
20
17
19
Connector (2) HE10/20 poles
2.0
C
I/O PCB Connector
16
1.7
-
-
18
20
+
17
19
C
+
C
FUS
+F
2.0
1
2.1
2
3.7
16
C
C
C
-
-
C
+
C
+
18
20
17
19
FUS
+F
Connector (2) HE10/20 poles
Supply Voltage
-
Disconnectable
connector
Shunt
16
2
C
Supply Voltage 1
1.7
C
0.1
C
I/O PCB Connector
2
1
C
Shunt
0.1
C
Supply Voltage 2
I/O PCB Connector
1
Connector (1) HE10/20 poles
0.0
C
0.0
Connector (1) HE10/20 poles
B
C
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
Length A x width B x height C
C version mm
mm
Note
2 x HE 10 connectors - 20 pole
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
3A
24 V DC / LED yellow
2A
3.15 A
24 V DC ± 10%
1 A (*)
3A
–
Yes - each channel
Green
+ or – selectable with a jumper
3A
24 V DC / LED yellow
2A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
24 V DC ± 10%
1 A (*)
3A
–
Yes - each channel
Green
+ or – selectable with a jumper
170 x 87.5 x 72
230 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
(*) Observe the max. permissible current for the common wires
Type
Type
Order No.
RS 32ES-D-I-L H/Z
9447950000 (1)
Ordering data
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
RS 32ES-D-I-L H/V
C : compact version
Order No.
C
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
9445950000
(1) Available upon customer request
B.33
RS ES-D-F - 32-channel with fuse
H-System – 2-wire (common + or –)
Version: screw connection
Dimensions
I/O PCB Connector
C
0.0
FUS
1
0.1
FUS
2
1.7
FUS
16
C
C
Shunt
-
18
20
+
17
19
C
C
FUS
+F
2.0
FUS
1
2.1
FUS
2
3.7
FUS
16
C
C
C
-
-
C
+
C
+
18
20
17
19
FUS
+F
Connector (2) HE10/20 poles
A
+
I/O PCB Connector
Supply Voltage 1
C
Connector (1) HE10/20 poles
B
Shunt
B
For 32-channel digital I/O cards
System H
Supply Voltage 2
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
≤ 25 V AC 50 V DC
1 A (*)
3A
0.5 A fuse on each channel
–
–
+ or – selectable with a jumper
3A
24 V DC / LED yellow
2A
3.15 A
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
mm
Note
248 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
Ordering data
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
B.34
Type
RS 32ES-D-F H/V
Order No.
9445980000
For 32-channel digital I/O cards
System H
RS ES-T - 32-channel
RS ES-T - 32-channel
H System – 3-wire (common + and –)
Version: screw connection - compact
H System – 3-wire (common + and –)
Version: tension clamp
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
C
B
Dimensions
2
1.7
16
-
Supply Voltage
+
-
18
20
+
+
17
19
FUS
+F
+F
1
2.1
2
I/O PCB Connector
+
3.7
16
+
18
20
17
19
1
0.1
2
1.7
16
+
-
18
20
+
+
17
19
FUS
+F
+F
2.0
1
2.1
2
3.7
16
+
+
+
-
18
20
+
+
17
19
FUS
+F
+F
Connector (2) HE10/20 poles
A
-
+
-
2.0
+
Connector (2) HE10/20 poles
-
-
-
I/O PCB Connector
+
Supply Voltage 1
1
Supply Voltage 2
C
0.0
0.1
+
-
Connector (1) HE10/20 poles
I/O PCB Connector
-
0.0
+
Connector (1) HE10/20 poles
B
I/O PCB Connector
-
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
Length A x width B x height C
C version mm
mm
Note
2 x HE 10 connectors - 20 pole
2 x HE 10 connectors - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
3A
24 V DC / LED yellow
2A
3.15 A
24 V DC ± 10%
1 A (*)
3A
–
–
Green
+ and –
3A
2 x 24 V DC / LED yellow (for each 16-channel block)
2A
3.15 A
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
≤ 25 V AC 50 V DC (version without LED) / 24 V DC ± 10% (versions with LED)
1 A (*)
3A
–
–
Green (versions with LED)
+ and –
176 x 87.5 x 72
221 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
(*) Observe the max. permissible current for the common wires
Type
RS 32ES-T H/V
RS 32ES-T-L H/V
Type
Order No.
RS 16ES-T-L H/Z
9447970000
Ordering data
Screw connection without LED
Screw connection with LED
Tension clamp connection without LED
Tension clamp connection with LED
Note
C
C
Order No.
9445960000
9445970000
C : compact version
B.35
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
B
For 32-channel digital I/O cards
System R
RS ES - 32-channel
RS ES-I – 32 disconnectable channels
System R – 1-wire cabling
Version: screw connection
System R – 1-wire cabling
Version: screw connection
RSV 1.6 connector - 36 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
RSV 1.6 connector - 36 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
max 150 V UC
1 A (*)
3A
–
–
–
–
–
max 150 V UC
2A
–
250 V max
1 A (*)
3A
–
Yes - each channel
–
–
–
max 250 V
2A
3.15 A
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
250 V AC
III
2
1.7 KV DC
-25…50 ºC
-40…60 ºC
148 x 87.5 x 72
188 x 87.5 x 72
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
Type
RS32ES RSV1,6/V
Type
RS32ES-I RSV1,6/V
Dimensions
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
mm
Note
Ordering data
Screw connection without LED
Screw connection with LED
Note
B.36
Order No.
9441510000
Order No.
9441870000
For 32-channel digital I/O cards
System R
RS ES-DP - 32-channel
RS ES-DP/F - 32-channel with fuse
R-System – 2-wire (common + or –)
Version: screw connection
R-System – 2-wire (common + or –)
Version: screw connection
B
Dimensions
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
mm
Note
RSV 1.6 connector - 36 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
RSV 1.6 connector - 36 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3A
–
–
–
+ or – selectable with a jumper
3A
max 150 V UC
2A
3.15 A
max 150 V UC
1 A (*)
3A
1 A fuse on each channel
–
–
+ or – selectable with a jumper
3A
max 150 V UC
2A
3.15 A
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
200 x 87.5 x 72
200 x 109 x 84
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
Type
RS32ES-DP RSV1,6/V
Type
RS32ES-DP/F RSV1,6/V
Ordering data
Screw connection without LED
Screw connection with LED
Note
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
Order No.
9441710000
Order No.
9441570000 (1)
(1) Available upon customer request
B.37
PLC Interfaces
H-, R- and S-System
Direct Inputs/Outputs for Digital Cards
B
For 32-channel digital I/O cards
System R
RS ES-3 E/I - 32 disconnectable channels
R System – 3-wire (common + and –)
Version: screw connection
Dimensions
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Operating voltage
Max. current per channel
Max. total current
Fuse per channel
Disconnection per channel
LED status indication per channel
Polarity distribution
Max. current of joint potential
PLC card supply voltage / LED voltage status
PLC card supply current
PLC card supply current fuse
RSV 1.6 connector - 36 pole
0.5…1.5 mm2 / 0.5…2.5 mm2 (AWG 26...16)
max 150 V UC
1 A (*)
3A
–
Yes - each channel
–
+ and –
3A
max 150 V UC
2A
3.15 A
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
< 150 V AC
III
2
1.1 KV DC
-25…50 ºC
-40…60 ºC
mm
Note
188 x 109 x 84
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
Ordering data
Screw connection without LED
Screw connection with LED
Note
B.38
Type
RS32E-3E/I RSV1,6/V
Order No.
9441610000
Type
No. of
channels
16
channels
H or R
System
H System
Functionalities
Type of
wiring
2-wire
Connection
Compact
version
Screw
C
C
C
V
V
V
Tension c.
Modules
1 LED
per chan.
Pluggable
optocoupler
L
L
L
O
O
O
Note: Preferred articles in bold
Order No.
Type
9446900000
9446910000
(*)
Page
RS16E-OD 24-48V H/V
B.40
RS16E-OD 115 H/V
B.41
9446920000 (*) RS16E-OD 230V H/V
PLC Interfaces
H-, R- and S-System
Module Overview – Opto-Decoupled Inputs/Outputs for Digital Cards
B.41
(*) Available upon customer request
B
B.39
PLC Interfaces
H-, R- and S-System
Opto-Decoupled Inputs for Digital Cards
For 16-channel digital cards
RSE OD – 16-channel
Dimensions
System H – Pluggable optocouplers
Version: screw connection
C
B
C
B
A
Technical data
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
C1
Connector HE10/20 poles
24…48 V UC
9…21 mA AC
7…16 mA DC
20 V AC
19 V DC
100 mA / 48 V–
24 up to 48 V DC
100 mA
1A
2A
C2
FUS
E1
R
Input PCB Connector
C1F
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
1
E8
R
C1F
8
C3
C4
FUS
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Operating Voltage
Input current AC
Input current DC
Switching voltage AC
Switching voltage DC
Max. switching current/voltage
Optocoupler polarisation voltage
Continuous current per optocoupler
Fuse (optocoupler power supply)
I/O card max. supply current
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
E9
R
C3F
Dimensions
Length A x width B x height C
9
E16
R
C3F
C version mm
Note
16
148 x 109 x 72
18
20
(*) Observe the max. permissible current for the common wires
17
19
Ordering data
Note
Type
RS16E-OD 24-48V H/V
C : compact version
Accessories
Note
B.40
Optocoupler - 4061180000
C
Order No.
9446900000
FUS
+
+
-
Supply Voltage
24-48 V version
For 16-channel digital cards
PLC Interfaces
H-, R- and S-System
Opto-Decoupled Inputs for Digital Cards
RSE OD – 16-channel
Dimensions
System H – Pluggable optocouplers
Version: screw connection
C
B
C
B
A
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Operating Voltage
Input current AC
Input current DC
Switching voltage AC
Switching voltage DC
Max. switching current/voltage
Optocoupler polarisation voltage
Continuous current per optocoupler
Fuse (optocoupler power supply)
I/O card max. supply current
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
C1
Connector HE10/20 poles
115 V UC / 230 V AC
7 mA AC / 7 mA AC
7 mA DC / –
80 V AC / 150 V AC
75 V DC / –
100 mA / 48 V–
24 up to 48 V DC
100 mA
1A
2A
FUS
C2
E1
R
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
1
E8
R
C1F
8
C3
C4
FUS
Input PCB Connector
C1F
E9
R
C3F
Dimensions
Length A x width B x height C
9
E16
R
C3F
C version mm
Note
16
148 x 109 x 72
18
20
(*) Observe the max. permissible current for the common wires
(**) No main-circuits
17
19
Ordering data
Note
Type
RS16E-OD 115 H/V
RS16E-DO 230V H/V
C : compact version
(1) Available upon customer request
C
C
Order No.
9446910000 (1)
9446920000 (1)
FUS
+
+
-
Supply Voltage
115 V version
230 V version
Accessories
Note
Optocoupler - 4061180000
B.41
PLC Interfaces
H-, R- and S-System
Module Overview - Relay Outputs for Digital Cards
Type
Functionalities
Connection
No. of
channels
H or R
System
Compact
version
8
chan.
H System
C
C
V
12
chan.
H System
C
V
B
Screw
Tension c.
V
16
channels
H System
C
C
C
C
C
V
V
V
V
V
V
V
32
channels
H System
C
C
V
V
Note: Preferred articles in bold
B.42
Z
Z
Z
Z
Type of
contact
Modules
Fuse
Order No.
Type
Page
9445000000
RSM8C-1CO H/V
B.43
1CO
9447000000
RSM8C-1CO H/Z
B.43
1CO
9445060000 (*) RSM12C-1CO H/V
1CO
9444610000
RSM16-NV/1CO 24V (-/+)
B.45
1CO
9444660000
RSM16-NZ/1CO 24V (-/+)
B.45
1CO
9445100000
RSM16C-1CO H/V
B.46
1CO
9447100000
RSM16C-1CO H/Z
B.46
1CO
1079390000 (*) RSM16 SLIM-1CO H/V
1CO
1094970000 (*) RSM16 SLIM-1CO H/V SOCKET
B.47
2CO
9445160000
RSM16-2CO H/V
B.48
9447160000
RSM16-2CO H/Z
B.48
9445140000
RSM16-1CO-Fo H/V
B.49
9445120000
RSM16-1CO-Fu H/V
B.50
9447120000
RSM16-1CO-Fu H/Z
B.50
9445180000
RSM16 1T/Solen. ctrl 24V DC H/V B.51
2CO
1CO
1CO
F
F
1NO
Z
Solen. ctrl.
1CO
1CO
Z
Force
function
P
E
B.44
B.47
1CO
1108470000 (*) RSM32C-1CO 24VDC H/V
B.52
1CO
9447200000
RSM32C-1CO H/Z
B.52
9445220000
RSM32-1CO-Fu H/V
B.53
1CO
F
(*) Available upon customer request
For 8-channel digital output cards
PLC Interfaces
H-, R- and S-System
Relay Outputs for Digital Cards
RSM-C – 8-channel
Dimensions
H System – 1CO relay
Versions: screw / tension clamp
B
C
B
A
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2A
Output PCB Connector
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
–
30 x 106 operations
mm
Note
Relay 1
21
24
22
31
34
32
Relay 2
81
84
82
Relay 8
Relay 3
Supply Voltage
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
11
14
12
110 x 109 x 68
(*) No main-circuits
+
+F
1
2
3
8
Connector HE10/20 poles
Dimensions
Length A x width B x height C
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
18
20
FUS
17
19
Ordering data
Screw connection
Tension clamp connection
Type
RSM8C-1CO H/V
RSM8C-1CO H/Z
Order No.
9445000000
9447000000
Note
Accessories
Note
Relay RCL314024 - 8693260000
Static relay ODC - 8576340000
Static relay OAC - 8576370000
B.43
PLC Interfaces
H-, R- and S-System
Relay Outputs for Digital Cards
For 12-channel digital output cards
RSM-C – 12-channel
Dimensions
H System – 1CO relay
Version: screw connection
B
C
B
A
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2A
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
mm
Note
147 x 109 x 68
(*) No main-circuits
Ordering data
Screw connection
Tension clamp connection
Type
RSM12C-1CO H/V
Order No.
9445060000
Note
Accessories
Note
B.44
Relay RCL314024 - 869326000
Relay 1
21
24
22
31
34
32
Relay 2
121
124
122
Relay 12
Relay 3
Supply Voltage
Dimensions
Length A x width B x height C
Output PCB Connector
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
11
14
12
Static relay ODC - 8576340000
Static relay OAC - 8576370000
+
+F
1
2
3
12
18
20
FUS
17
19
HE 10 20-pole connector
Connector HE10/20 poles
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
–
30 x 106 operations
For 16-channel digital output cards
PLC Interfaces
H-, R- and S-System
Relay Outputs for Digital Cards
RSM-S – 16-channel
Dimensions
1CO relay
Versions: screw / tension clamp
B
C
B
A
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
–
30 x 106 operations
Output PCB Connector
11
14
12
250 V AC
III
2
1.2KVrms
-25…40 ºC
-40…60 ºC
mm
Note
Relay 1
1
E1
21
24
22
31
34
32
Relay 2
2
E2
Relay 3
3
E3
161
164
162
267 x 87.5 x 68
Input PCB Connector
24 V ±10%
22 mA / 0.5 W
LED green
–
2A
Connector HE10/20 poles
Relay 16
16
E16
(*) No main-circuits
Ordering data
Screw connection
Tension clamp connection
Type
RSM16-NV/1CO 24V (-/+)
RSM16-NZ/1CO 24V (-/+)
Order No.
9444610000
9444660000
Supply Voltage
Dimensions
Length A x width B x height C
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.5…1.5 / 0.5…1.5 mm2 (AWG 16…26)
COM
18
20
U
17
19
Note
Accessories
Note
Relay RCL314024 - 8693260000
Static relay ODC - 8576340000
Static relay OAC - 8576370000
B.45
PLC Interfaces
H-, R- and S-System
Relay Outputs for Digital Cards
For 16-channel digital output cards
RSM-C – 16-channel
Dimensions
H System – 1CO relay
Versions: screw / tension clamp
B
C
B
A
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2A
mm
Note
185 x 109 x 68
(*) No main-circuits
Ordering data
Screw connection
Tension clamp connection
Type
RSM16C-1CO H/V
RSM16C-1CO H/Z
Order No.
9445100000
9447100000
Note
Accessories
Note
B.46
Relay RCL314024 - 8693260000
Relay 1
21
24
22
31
34
32
Relay 2
161
164
162
Relay 16
Relay 3
Supply Voltage
Dimensions
Length A x width B x height C
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
11
14
12
Static relay ODC - 8576340000
Static relay OAC - 8576370000
+
+F
1
2
3
16
18
20
FUS
17
19
Connector HE10/20 poles
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Output PCB Connector
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
–
30 x 106 operations
For 16-channel digital output cards
PLC Interfaces
H-, R- and S-System
Relay Outputs for Digital Cards
RSM SLIM – 16-channel
Dimensions
H System – with 1CO relay / empty socket
Version: screw connection - compact
B
C
C
B
A
Technical data
C version mm
Note
24 V ±10%
8 mA / 0.2 W
LED green
–
2A
Output PCB Connector
1CO
1500 VA / 250 V AC
6 A version
4 A/6 A
AgSnO2
–
5 x 106 operations
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
11
14
12
Relay 1
21
24
22
31
34
32
Relay 2
161
164
162
Relay 16
Relay 3
Supply Voltage
Dimensions
Length A x width B x height C
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
111 x 87.5 x 85
(*) No main-circuits
+
1
2
3
16
Connector HE10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
18
20
17
19
Ordering data
Equipped with 1 CO relay screw connection
Empty slot, screw connection
Note
Type
RSM16 SLIM-1CO H/V
RSM16 SLIM-1CO H/V SOCKET
C
C
Order No.
1079390000 (1)
1094970000 (1)
C : compact version
(1) Available upon customer request
Accessories
Note
1CO relay - 4061590000
Optocoupler ODC 24V/2A - 4061190000
B.47
PLC Interfaces
H-, R- and S-System
Relay Outputs for Digital Cards
For 16-channel digital output cards
RSM-2CO – 16-channel
Dimensions
System H – 2CO relay
Versions: screw / tension clamp
B
C
B
A
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
Output PCB Connector
2CO
2000 VA / 250 V AC
2x8 A version
4 A/8 A
AgNi 90/10
–
30 x 106 switching cycles
121
111
114
112
211
214
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Connector HE10/20 poles
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2A
212
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
311
314
Relay 1
1
Relay 2
2
Relay 3
3
Relay 16
16
124
122
221
224
222
331
334
332
312
1621
1624
1611
1622
1614
mm
Note
1612
263 x 109 x 75
Supply Voltage
Dimensions
Length A x width B x height C
(*) No main-circuits
Ordering data
Screw connection
Tension clamp connection
Type
RSM16-2CO H/V
RSM16-2CO H/Z
Note
Accessories
Note
B.48
2CO Relay - 4058570000
Order No.
9445160000
9447160000
+
+F
18
20
FUS
17
19
For 16-channel digital output cards
PLC Interfaces
H-, R- and S-System
Relay Outputs for Digital Cards
RSM-Fo - 16-channel with force function
Dimensions
H System – 1CO relay
Version: screw connection
B
C
B
A
A
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2A
Switch
1CO
3000 VA / 250 V AC
16 A version
2 A/16 A
AgNi 90/10
–
30 x 106 operations
Output PCB Connector
11
14
12
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
Note
SW2
161
164
162
SW16
Relay 2
Relay 3
SW3
Relay 16
2
3
16
263 x 109 x 75
(*) No main-circuits
Ordering data
Screw connection
Tension clamp connection
21
24
22
31
34
32
Supply Voltage
mm
1
SW1
Connector HE10/20 poles
Dimensions
Length A x width B x height C
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
Type
RSM16-1CO-Fo H/V
+
+F
18
20
FUS
17
19
Order No.
9445140000
Note
Accessories
Note
Relay RCL314024 - 8693260000
Static relay ODC - 8576340000
Static relay OAC - 8576370000
B.49
PLC Interfaces
H-, R- and S-System
Relay Outputs for Digital Cards
For 16-channel digital output cards
RSM-Fu – 16-channel with fuse
Dimensions
H System – 1CO relay
Versions: screw / tension clamp
B
C
B
A
A
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.5...1.5 / 0.5...1.5 mm2 (AWG 16...26)
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2A
mm
Note
261 x 109 x 75
(*) No main-circuits
Ordering data
Screw connection
Tension clamp connection
Type
RSM16-1CO-Fu H/V
RSM16-1RT-Fu H/Z
Order No.
9445120000
9447120000
Note
Accessories
Note
B.50
Relay RCL314024 - 8693260000
FUS
21
24
22
31
34
32
FUS
161
164
162
FUS
Static relay ODC - 8576340000
Static relay OAC - 8576370000
Relay 1
Relay 2
Relay 3
FUS
Supply Voltage
Dimensions
Length A x width B x height C
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
11
14
12
Relay 16
+
+F
1
2
3
16
18
20
FUS
17
19
Connector HE10/20 poles
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Output PCB Connector
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
5 A fuse on each channel
30 x 106 operations
For 16-channel digital output cards
PLC Interfaces
H-, R- and S-System
Relay Outputs for Digital Cards
RSM-Solen. ctrl. - 16-channel for solenoid
Dimensions
H System – 1O relay
Version: screw connection
B
C
B
A
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2A
C1
C2
1CO
3000 VA / 250 V AC
16 A version
2 A/16 A
AgNi 90/10
–
30 x 106 operations
Relay 1
I1
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
FUS
Relay 8
I8
F8
FUS
C3
C4
Relay 9
I9
F9
Relay 16
Note
F16
290 x 109 x 75
(*) No main-circuits
Ordering data
Screw connection
Tension clamp connection
Type
RSM16 1T/Solen. ctrl. 24V DC H/V
16
FUS
Supply Voltage
mm
9
FUS
I16
Dimensions
Length A x width B x height C
8
Connector HE10/20 poles
Output PCB Connector
F1
1
+
+F
18
20
FUS
17
19
Order No.
9445180000
Note
Accessories
Note
Relay RCL314024 - 8693260000
Static relay ODC - 8576340000
Static relay OAC - 8576370000
B.51
PLC Interfaces
H-, R- and S-System
Relay Outputs for Digital Cards
For 32-channel digital output cards
RSM-C – 32-channel
Dimensions
H System – 1 CO relay
Versions: screw / tension clamp
B
C
B
A
Technical data
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2A
Relay 1
21
24
22
31
34
32
Relay 2
161
164
162
Relay 16
Relay 3
365 x 109 x 68
(*) No main-circuits
+
1
2
3
16
18
20
17
19
FUS
+F
171
174
172
Relay 17
181
184
182
191
194
192
Relay 18
321
324
322
Relay 32
Relay 19
1
2
3
Screw connection
Tension clamp connection
Note
Type
RSM32C-1CO 24VDC H/V
RSM32C-1CO H/Z
Order No.
1108470000 (1)
9447200000
(1) Available upon customer request
Accessories
Note
B.52
Relay RCL314024 - 8693260000
Static relay ODC - 8576340000
Static relay OAC - 8576370000
Supply Voltage 2
Ordering data
+
+F
16
18
20
FUS
17
19
Connector (2) HE10/20 poles
Note
Output PCB Connector
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
mm
11
14
12
Supply Voltage 1
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
–
30 x 106 operations
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
Output PCB Connector
2 x HE 10 connector - 20 pole
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
Connector (1) HE10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
For 32-channel digital cards
PLC Interfaces
H-, R- and S-System
Relay Outputs for Digital Cards
RSM-Fu – 32-channel with fuse
Dimensions
H System – 1 CO relay
Version: screw connection
B
C
B
A
A
Technical data
Output PCB Connector
24 V ±10%
17 mA / 0.4 W
LED green
3.15 A
2A
250 V AC
III
2
1.2 KVrms
-25…40 ºC
-40…60 ºC
mm
FUS
21
24
22
31
34
32
FUS
161
164
162
FUS
511 x 109 x 75
(*) No main-circuits
Relay 1
Relay 2
Relay 3
FUS
Relay 16
+
FUS
181
184
182
191
194
192
FUS
321
324
322
FUS
2
3
16
18
20
17
19
FUS
+F
171
174
172
1
Relay 17
Relay 18
Relay 19
FUS
1
2
3
Screw connection
Tension clamp connection
Type
RSM32-1CO-Fu H/V
Order No.
9445220000
Note
Accessories
Note
Relay RCL314024 - 8693260000
Static relay ODC - 8576340000
Static relay OAC - 8576370000
Supply Voltage 2
Ordering data
Relay 32
+
+F
16
Connector (2) HE10/20 poles
Note
11
14
12
Supply Voltage 1
1CO
3000 VA / 250 V AC
16 A version
5 A/16 A
AgNi 90/10
5 A fuse on each channel
30 x 106 operations
Output PCB Connector
Dimensions
Length A x width B x height C
2 x HE 10 20-pole connectors
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
Connector (1) HE10/20 poles
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input data
Coil rated voltage
Coil rated current/power
Coil status indicator
PLC card supply current fuse
I/O card max. supply current
Output data
Contact configuration
Max. switching power/voltage
Relay type
Max. continuous/inrush current
Contact material
Fuse (contact)
Mechanical service life
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
18
20
FUS
17
19
B.53
PLC Interfaces
H-, R- and S-System
Module Overview – Analog Input/Output
B
Type
Number
of
channels
4
channels
8
channels
PLC
Standard
Standard
8
Premium
channels P (Télémécanique)
9
Micro
channels M (Télémécanique)
16
channels
Standard
Functionalities
Compact
version
Connection
Screw
Tension c.
Common
distribution
Disconnectable
Test
points
V
V
M
M
I
T
V
V
M
M
M
I
I
T
T
M
I
Z
V
V
V
V
Z
Note: Preferred articles in bold
B.54
Modules
M
M
M
I
I
T
T
Order No.
Type
Page
9448000000
RS4AIO-DP SD/V
B.55
9448100000
RS4AIO/I-M-DP SD/V
B.55
9448010000
RS8AIO-DP SD/V
B.56
9448110000
RS8AIO/I-M-DP SD/V
B.56
9449110000
RS8AIO/I-M-DP SD/Z
B.56
9448030000
RS8AI PREM/APR SD/V
B.57
9448040000
RS8E1AO MICRO SD/V
B.57
9448020000
RS16AIO-DP SD/V
B.58
9448120000
RS16AIO/I-M-DP SD/V
B.58
9449120000
RS16AIO/I-M-DP SD/Z
B.58
For 4-channel analog I/O cards
RS AIO-DP - 4-channel
RS AIO/I-M-DP - 4-channel
Common distribution
Version: screw connection
Common distribution, disconnection and test
Version: screw connection
Dimensions
B
Disconnectable
connector
B
3
0-
11
1+
4
1-
12
C
0-
3-
14
SubD male
A
Shunt
Supply Voltage
C
+
C
+
I/O PCB Connector
6
ConnectorSubD 15 poles
3+
1
9
+F
Shielded
C
1+
4
1-
12
3+
6
3-
14
C
2
10
FUS
11
C
Shunt
C
C
3
Test point
C
Supply Voltage
I/O PCB Connector
C
0+
C
C
+
C
+
Connector SubD 15 poles
0+
C
2
10
1
9
FUS
+F
Shielded
C
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Number of channels
Operating voltage
Common distribution
PLC card supply current fuse
Disconnection
Current measuring test point
Voltage measuring test point
Continuous shielding
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
mm
15-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
15-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
4
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
–
–
–
Yes
4
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
Yes - each channel
Yes - 2 female testing points dia. 4 mm
Yes
Yes
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
75 x 87.5 x 72
73 x 109 x 81
Note
Ordering data
Screw connection
Tension clamp connection
Type
RS4AIO-DP SD/V
Order No.
9448000000
Type
RS4AIO/I-M-DP SD/V
PLC Interfaces
H-, R- and S-System
Input / Output for Analog Cards
Order No.
9448100000
Note
B.55
RS AIO-DP - 8-channel
RS AIO/I-M-DP - 8-channel
Common distribution
Version: screw connection
Common distribution, disconnection and test
Versions: screw / tension clamp
Dimensions
Disconnectable
connector
B
3
0-
16
1+
4
1-
17
0+
0-
7-
23
A
Shunt
C
+
C
+
I/O PCB Connector
10
Connector SubD 25 poles
7+
1
14
+F
Shielded
C
1+
4
1-
17
7+
10
7-
23
C
2
15
FUS
16
C
Shunt
C
C
Test point
C
Supply Voltage
I/O PCB Connector
C
C
3
C
C
+
C
+
Connector SubD 25 poles
0+
C
Supply Voltage
B
For 8-channel analog I/O cards
SubD male
PLC Interfaces
H-, R- and S-System
Input / Output for Analog Cards
2
15
1
14
FUS
+F
Shielded
C
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Number of channels
Operating voltage
Common distribution
PLC card supply current fuse
Disconnection
Current measuring test point
Voltage measuring test point
Continuous shielding
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
mm
25-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
25-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
8
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
–
–
–
Yes
8
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
Yes - each channel
Yes - 2 female testing points dia. 4 mm
Yes - 2 female testing points dia. 4 mm
Yes
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
117 x 87.5 x 72
114 x 109 x 81
Note
Ordering data
Screw connection
Tension clamp connection
Note
B.56
Type
RS8AIO-DP SD/V
Order No.
9448010000
Type
RS8AIO/I-M-DP SD/V
RS8AIO/I-M-DP SD/Z
Order No.
9448110000
9449110000
For Télémécanique
Premium and Micro
PLC analog I/O cards
RS8AI PREM/APR – 8-channel
RS8I1OA MICRO – 9-channel
8 analog inputs
Version: screw connection
8 analog inputs and 1 output
Version: screw connection
PLC Interfaces
H-, R- and S-System
Input / Output for Analog Cards
B
Dimensions
Shunt
0+
IV
C
0-
IC
1+
IV
C
16
IC
2+
IV
2-
5
4
17
IC
7+
IV
1
S0-
2
E0+
10
E0-
14
E1+
3
25
E1E2+
11
E2-
E7+
E7-
6
24
15
10V
7-
12
C
SubD male
Shunt
A
+
C
Connector SubD 15 poles
3
C
S0+
15
Connector SubD 25 poles
1C
Input PCB Connector
1
14
C
C
2
I/O PCB Connector
B
IC
GND
10V
GND
10V
GND
+
10V
GND
Shielded
10V
GND
Shielded
C
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Number of channels
Operating voltage
Common distribution
PLC card supply current fuse
Disconnection
Current measuring test point
Voltage measuring test point
Continuous shielding
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
mm
Note
25-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
15-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
8
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
–
Yes
–
–
Yes
9
≤ 25 V AC 50 V DC
Shielding
–
–
–
Yes
Yes
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
< 50 V AC
II
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
116 x 87.5 x 72
100 x 87.5 x 72
Current/Voltage Switchable
Ordering data
Screw connection
Tension clamp connection
Type
RS8AI PREM/APR SD/V
Order No.
9448030000
Type
RS8I1OA MICRO SD/V
Order No.
9448040000
Note
B.57
RS AIO-DP - 16-channel
RS AIO/I-M-DP - 16-channel
Common distribution
Version: screw connection
Common distribution, disconnection and test
Version: screw / tension clamp
Dimensions
Disconnectable
connector
B
0+
3
0-
22
1+
4
1-
23
C
0+
0-
37
+
C
+
2
21
1
20
FUS
+F
Shielded
C
1+
4
1-
23
15+
18
15-
37
C
C
Supply Voltage
Shunt
C
I/O PCB Connector
18
15-
Connector SubD 37 poles
15+
22
C
Shunt
C
C
A
Test point
C
+
C
+
Connector SubD 37 poles
I/O PCB Connector
C
3
C
C
Supply Voltage
B
For 16-channel analog I/O cards
SubD male
PLC Interfaces
H-, R- and S-System
Input / Output for Analog Cards
2
21
1
20
FUS
+F
Shielded
C
Technical data
Connection
Connection to PLC
Connection type V (screw clamp) Flexible/Solid
Connection type Z (tension clamp) Flexible/Solid
Input-Output Data
Number of channels
Operating voltage
Common distribution
PLC card supply current fuse
Disconnection
Current measuring test point
Voltage measuring test point
Continuous shielding
Insulation coordination (EN50178)
Rated voltage
Overvoltage category
Pollution degree
Insulation test voltage
Ambient temperature
Storage temperature
Dimensions
Length A x width B x height C
mm
37-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
–
37-pole D-SUB male connector
0.5…4 mm2 / 0.5…6 mm2 (AWG 26...12)
0.2...1.5 mm2 / 0.2...2.5 mm2 (AWG 24...14)
16
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
–
–
–
Yes
16
≤ 25 V AC 50 V DC
Shield, + or – (selectable with jumper)
3.15 A
Yes - each channel
Yes - 2 female testing points dia. 4 mm
Yes - 2 female testing points dia. 4 mm
Yes
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
< 50 V AC
III
2
0.5 KV DC
-25…50 ºC
-40…60 ºC
205 x 87.5 x 72
197 x 109 x 81
Note
Ordering data
Screw connection
Tension clamp connection
Note
B.58
Type
RS16AIO-DP SD/V
Order No.
9448020000
Type
RS16AIO/I-M-DP SD/V
RS16AIO/I-M-DP SD/Z
Order No.
9448120000
9449120000