File E14900 Project 93NK2721 Issued: April 1, 1993 Revised: October 25, 2005 REPORT on COMPONENT - INDUSTRIAL CONTROL EQUIPMENT, MAGNETIC MOTOR CONTROLLERS Siemens Energy & Automation, Inc. Norcross, GA Copyright © 1993 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. authorizes the above named company to reproduce that portion of this Report consisting of this Cover Page through Page 5. File E14900 Vol. 8 Vol. 12 Sec. 5 Sec. 1 and Report Page 1 Issued: Revised: 1993-04-01 2005-10-25 DESCRIPTION PRODUCT COVERED: Definite purpose contactors, Cat. No. 42, followed by A, B, or C, followed by F, followed by 1, 2, 3, 6, 7, or 8 followed by 2 or 5, followed by A, B or C, followed by 1, 2, 3, 4, 5, 6, 7, D, E, F, G, H, J, K, L, or Y with or without K, L, M, N, P, Q, R, S, T, V, W, Y, or Z, with or without A, B, C, D, E, F, G, H, K, L, M, N, O, P, R or S. Definite purpose contactors, Cat. No. 42, followed by A, B, or C, followed by F, followed by 1, 2, 3, 6, 7 or 8 followed by 5, followed by A, B or C, followed by 1, 2, 3, 4, 5, 6, 7, D, E, F, G, H, J, K, L or Y, with Suffix A through Z, followed by A through Z, followed by A through Z. Definite purpose reversing contactors, Cat. No. 44, followed by A, B or C, followed by F, followed by 2, 3 or 4, followed by 0, 1, 2, A, B or E, followed by A, B, C or D, followed by D, E, F, G, H, J, K or Y, with or without Suffix A through Z, followed by A through Z, followed by A through Z. * Definite purpose starters, Cat. No. 16, followed by A, B, or C, followed by F, followed by 1, 2 or 3, followed by 2, 3, 4 or 5, followed by A or B, followed by D, E, F, G, H, J, K, L or Y with or without 3, 4 or 8, with or without A, B, C, D, E, F or K. Definite purpose starters, Cat. No. 16, followed by A, B, or C, followed by F, followed by 1, 2 or 3, followed by 2, 3, 4 or 5, followed by A or B, followed by D, E, F, G, H, J, K, L or Y, with Suffix A through Z, followed by A through Z, followed by A through Z. Definite purpose two speed contactors, Cat. No. 34, followed by A, B or C, followed by F, followed by 2, 3 or 4, followed by 2, 3 or 4, followed by A, B, C or D, followed by D, E, F, G, H, J, K, L or Y, with Suffix A through Z, followed by A through Z, followed by A through Z. GENERAL: These devices are 1, 2, 3, or 4-pole open or enclosed type magnetically operated definite purpose starters and contactors and reversing contactors and two speed contactors. They are intended to be used in heating, air conditioning and refrigeration applications or industrial applications where the suitability of the combination has been determined by Underwriters Laboratories Inc. File E14900 Vol. 8 Vol. 12 Sec. 5 Sec. 1 and Report Page 1A Issued: Revised: 1993-04-01 2005-06-29 Ratings - They are rated: Cat. No. 42AF 44AF 16AF 34AF 42BF 44BF 16BF 34BF 34BF 42CF 44CF 16CF 34CF Voltage FLA Horsepower LRA 1 phase 120 200 240 25 480 25 600 25 240+++ 150 125 100 15 2 3 90 120 200 240 30 480 30 600 30 240+++ 180 150 120 20 2 5 120 120 200 240 40 480 40 600 40 240+++ 240 35 240 200 160 30 290 3 7.5 180 - Resistive 3 phase 5 5 10 10 - A (++++) 35 35 35 35 35 7.5 7.5 15 15 - 40 40 40 40 40 - 10 50 50 10 20 20 - 50 50 50 - - - Tungsten and Ballast: 42AF, 20 Amps, 480 V ac, maximum, 1 phase, 2-pole and 3 phase, 3-pole. 42BF, 30 Amps, 480 V ac, maximum, 1-phase, 2-pole and 3 phase, 3-pole. Except as noted, all ratings are per pole, 1-pole, 1-phase; 2-poles, 1-phase; 2 poles, 3-phase; 3 poles, 3-phase. (Normally open). (+++) - 2-poles, normally closed, breaking all lines. # - All the ratings shown apply to all products (All Cat. Nos. 42, 44, 16, and 34 utilize the same contactor). Cat. No. 42AF may also have the same FLA/LRA ratings as the Cat. No. 42BF Contactor, for 30,000 operations of endurance. File E14900 Vol. 8 Vol. 12 Sec. 5 Sec. 1 and Report Page 2 Issued: Revised: 1993-04-01 2005-06-29 All noninductive ratings were tested for 250,000 operations to cover resistance heating applications. All Definite Purpose Ratings are per-pole. The motor FLA ratings for Cat. No. 42BF and 42CF devices provided with covers were tested for 250,000 operations of endurance. The contactors provided with covers were additionally tested for use in applications where the stalled rotor test does not involve more than 6000 operations for the following ratings: Cat. No. V ac LRA On/Off Ratio Maximum "On" Time Minimum "Off" Time 42AF 16AF 240 (+) 480 (+) 600 (+) 240 (++) 150 125 100 90 1/9 1/9 1/9 1/9 10 10 10 10 90 90 90 90 42BF 16BF 240 (+) 480 (+) 600 (+) 240 (++) 180 150 120 120 1/9 1/9 1/9 1/9 10 10 10 10 90 90 90 90 42CF 16CF 240 (+) 480 (+) 600 (+) 240 (++) 240 200 160 180 1/9 1/9 1/9 1/9 10 10 10 10 90 90 90 90 (+) - 2-poles, 1-phase; 3-poles, 3-phase, breaking all lines. (Normally open) (++) - 2-poles, 1-phase, normally closed, breaking all lines. At the request of the manufacturer, the open type devices provided with covers were investigated for part winding applications where the maximum full-load and locked-rotor currents do not exceed those shown below. The devices were tested for 30,000 operations "making" the full-load current and "breaking" the locked-rotor current. The tests were conducted 3-phase, 3-pole (covers 1-phase, 2-pole) at a rate of six operations per minute. V 42AF 42AF 42AF 240 460 600 FLA LRA 25 25 25 150 125 100 File E14900 Vol. 8 Vol. 12 Sec. 5 Sec. 1 and Report Page 2A V FLA LRA 42BF 42BF 42BF 240 480 600 30 30 30 180 150 120 42CF 42CF 42CF 240 480 600 40 40 40 240 200 160 Coil Ratings: Issued: Revised: 1993-04-01 2006-06-26 See Nomenclature, Position V. Short Circuit Current Ratings – These devices were tested for the following shortcircuit current ratings. The ratings apply to all types of devices covered by this Report (contactors, starters & reversers.) Cat. No. Suffix Voltage AF AF AF AF AF BF BF BF BF BF CF CF CF CF CF 600 480 480 480 240 600 480 480 480 240 600 480 480 480 240 Protective Device + Type/Max. Amp Rating Class J Fuse/60 NEG/50 NGG/50 HEG/50 BQ3B/50 Class J Fuse/60 NEG/60 NGG/60 HEG/60 BQ3B/60 Class J Fuse/100 NEG/80 NGG/80 HEG/80 BQ3B/80 Short-Circuit Current RMS Symmetrical Amperes 100,000 65,000 65,000 65,000 24,000 100,000 65,000 65,000 65,000 24,000 100,000 65,000 65,000 65,000 24,000 + - Siemens Listed Cat. No. BQ3B, NGG3B, NEG3B and HEG3B circuit breakers Two types of auxiliary contact blocks may be provided. Unlisted Component Siemens Accessories, Cat. Nos. 49ACR, with suffixes, may be factory- or fieldinstalled. They are rated pilot duty, A600 and P600. As an alternate, Recognized Component Special Use Switches (WOYR2), made by Micro Switch or Cherry Electric may be used, and are rated as follows. They are mounted as noted in the Description, Fig. 1. File E14900 Project 93NK8633A Issued: Revised: October 1, 1993 October 25, 2005 REPORT on COMPONENT - INDUSTRIAL CONTROL EQUIPMENT, MAGNETIC MOTOR CONTROLLERS Siemens Energy & Automation, Inc. Norcross, GA Copyright © 1993 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. authorizes the above named company to reproduce that portion of this Report consisting of this Cover Page through Page 5. File E14900 Vol. 8 Vol. 12 Sec. 6 Sec. 2 and Report Page 1 Issued: Revised: 1993-10-01 2005-10-25 DESCRIPTION PRODUCT COVERED: by by N, P, Definite F, followed 1, 2, 3, 4, O, P, Q, R, R or S. purpose contactors, Cat. No. 42, followed by D or E, followed by 1 or 3, followed by 2 or 5, followed by A, B or C, followed 5, 6, 7, D, E, F, G, H, J, K, L or Y, with or without K, L, M, S, T, V, W or Z, with or without A, B, C, D, E, F, K, L, M, N, Definite purpose contactors, Cat. No. 42, followed by D or E, followed by F, followed by 1 or 3, followed by 2 or 5, followed by A, B or C, followed by 1, 2, 3, 4, 5, 6, 7, D, E, F, G, H, J, K, L or Y, with Suffix A through Z, followed by A through Z, followed by A through Z. Definite purpose reversing contactors, Cat. No. 44, followed by D or E, followed by F, followed by 2 or 3, followed by 0, 1, 2, A, B or E, followed by A, B, C or D followed by D, E, F, G, H, J, K, L or Y, with or without Suffix A through Z, followed by A through Z, followed by A through Z. Definite purpose starters, Cat. No. 16, followed by D or E, followed by F, followed by 1, 2 or 3, followed by 2, 3, 4 or 5, followed by A or B, followed by D, E, F, G, H, J, K, L or Y, with or without 3 or 4, with or without A, B, C, D, E, F, or K. Definite purpose starters, Cat. No. 16 followed by D or E, followed by F, followed by 1, 2 or 3, followed by 2, 3, 4 or 5, followed by A or B, followed by D, E, F, G, H, J, K, L or Y, 7 or 8, with Suffix A through Z, followed by A through Z, followed by A through Z. Definite purpose two-speed contactors, Cat. No. 34, followed by D or E, followed by F, followed by 2, 3 or 4, followed by A, B, C or D, followed by D, E, F, G, H, J, K or L or Y with Suffix A through Z, followed by A through Z, followed by A through Z. GENERAL: These devices are open type magnetically operated definite purpose contactors, starters, reversing contactors and two-speed contactors. They are intended to be used in heating, air conditioning and refrigeration applications or industrial applications where the suitability of the combination has been determined by Underwriters Laboratories Inc. File E14900 Vol. 8 Vol. 12 Sec. 6 Sec. 2 and Report Page 1A Issued: Revised: 1993-10-01 2005-06-29 Ratings - They are rated: hp 3 Phase Resistive A (+++) Cat. No. Voltage FLA LRA 1 Phase 16, 34, 42, 44DF 120 200 240 480 600 (+) (+) (+) (++) (++) 50 50 50 300 250 200 3 10 - 15 15 30 30 63 63 63 63 63 16, 34, 42, 44EF 120 200 240 480 600 200 (+) (+) (+) (++) (++) (+) 60 60 60 - 360 300 240 - 5 10 - 20 20 40 40 20 75 75 75 75 75 - (+) - 1 pole, 1 phase; 2 pole, 1 phase; 3 poles, 3 phase, breaking all lines. (++) - 2 poles, 1 phase; 3 poles, 3 phase, breaking all lines. # - All the ratings shown apply to all products (All Cat. Nos. 42, 44, 16, and 34 utilize the same contactor). (+++) – Resistive ratings are per pole, including 1 pole, 1 phase; 2 poles, 1 phase; 3 poles, 3 phase. (Wye or inside the delta, normally open). Tungsten and Ballast 42EF, 60 Amps, 480 V ac, maximum, 1 phase, 2-pole and 3 phase, 3pole. 42DF contactors are also rated 65VDC, 90 Amps, resistive, 3 poles in parallel. The Cat. No. 42DF contactors also have a rating of 240 V ac, 54 fullload amps, 300 locked-rotor amps. The Cat. No. 42EF contactors also have ratings of 65 full-load amperes, with the same locked-rotor currents as indicated above. All noninductive ratings were tested for 250,000 operations to cover resistance heating applications. Single phase definite purpose ratings at 120 V and 240 V are per pole. All three phase ratings require the contactor to break all lines. The motor FLA ratings were tested for 100,000 operations of endurance. File E14900 Vol. 8 Vol. 12 Sec. 6 Sec. 2 and Report Page 2 Issued: Revised: 1993-10-01 2006-06-26 The devices provided with covers may be used to control motors having inherent overheating protectors controlling the coil circuit of contactors. The contactors were additionally tested for use in applications where the stalled rotor test does not involve more than 6000 operations for the following ratings: Cat. No. V ac LRA On/Off Ratio Maximum "On" Time Minimum "Off" Time 16, 42DF 240 480 600 300 250 200 1/9 1/9 1/9 10 10 10 90 90 90 16, 42EF 240 480 600 360 250 200 1/9 1/9 1/9 10 10 10 90 90 90 At the request of the manufacturer, the open type devices provided with covers were investigated for part winding applications where the maximum full-load and locked-rotor currents do not exceed those shown below. The devices were tested for 30,000 operations "making" the full-load current and "breaking" the locked-rotor current. The tests were conducted 3-phase, 3-pole (covers 1-phase, 2-pole) at a rate of six operations per minute. 42DF 42DF 42DF 240 480 600 50 50 50 300 250 200 42EF 42EF 42EF 240 480 600 60 60 60 360 240 192 Short Circuit Current Ratings – These devices were tested for the following short-circuit current ratings. The ratings apply to all types of devices covered by this Report (contactors, starters & reversers.) Protective Device + Current Cat. No. Suffix Voltage DF DF DF DF DF EF EF EF EF EF 600 480 480 480 240 600 480 480 480 240 Type/Max. Amp Rating Class J Fuse/100 NEG/100 NGG/100 HEG/100 BQ3B/100 Class J Fuse/200 NEG/125 NGG/125 HEG/125 BQ3B/100 Short-Circuit RMS Symmetrical Amperes 100,000 65,000 65,000 65,000 24,000 100,000 65,000 65,000 65,000 24,000 + - Siemens Listed Cat. No. BQ3B, NGG3B, NEG3B and HEG3B circuit breakers Two types of auxiliary contact blocks may be provided. Unlisted Component Siemens accessories, Cat. Nos. 49ACR, with suffixes, may be factory or field installed. They are rated pilot duty, A600 and P600. As an alternate, Recognized Component special use switches (WOYR2), made by Micro Switch or Cherry Electric may be used, and are rated as follows. They are mounted as noted in the Description, Fig. 1. File E14900 Project 74CH3772 August 30, 1974 REPORT on COMPONENT – INDUSTRIAL CONTROL EQUIPMENT Furnas Electric Co. Batavia, Ill. Copyright © 1974 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. authorizes the above named company to reproduce the latest pages of that portion of this Report consisting of this Cover Page through Page 6. *File E14900 Vol. 8 Sec. 10 and Report Page 1 Issued: 8-30-74 Revised: 5-10-02 DESCRIPTION PRODUCT COVERED: Cat. Nos. 42FE and 42GE followed by 1 or 3 followed by 2 or 5 followed by A or B followed by A, C, D, E, F, G, H, J, L, S, or X8, with or without 106, 123, 134, 151, 152, 154, 160, 166, 174 through 187, 189 through 194, 196 through 206, 211 through 300 with or without R, or 100R through 999R or X149 with or without Suffix GA, GB, GC, GD, GH, GJ, GR, GS or GT with or without D7. Cat. No. 16 or 42FE or GE followed by a six digit suffix number, may be followed by R. Cat. No. 42FE107202F. Cat. No. 16FE or -GE followed by 3, followed by 2 or 5 followed by A or B followed by A, C, D, E, F, G, H, J, L, S, or X8, with or without suffix 81, with or without X243, with or without GA, GB, GC, GD, GE, GF, GH, GJ, GR, GS or GT with or without D7, with or without 100R through 999R. GENERAL: These devices are open or enclosed magnetically operated definite purpose contactors. They are intended to be used in air conditioning and refrigeration equipment and industrial applications where the suitability of the combination has been determined by Underwriters Laboratories Inc. Ratings - They are rated: Contact Ratings: Cat. No. 16FE 16FE 16FE 16FE 16FE 16GE 16GE 16GE 16GE and and and and and and and and and 42FE 42FE 42FE 42FE 42FE 42GE 42GE 42GE 42GE Above 240 V breaking all times. V ac FLA LRA 120 200 240 480 600 200 240 480 600 75 75 75 90 90 90 450 375 300 540 450 360 Noninductive, A 93 93 93 120 120 120 120 hp 3 Phase 1 Phase 20 25 40 40 25 30 60 60 5 15 - Cat. No. 42GE is additionally rated 240 V ac, 135 A resistive and tungsten and ballast, 100 Amps, 480 V ac, maximum, 1 phase, 2-pole and 3 phase, 3-pole. Coil Ratings: 24-600 V ac, 50/60 Hz. File E14900 Vol. 8 Cat. No. 16FE, 16FE, 16FE, 16GE, 16GE, 16GE, Sec. 10 and Report Page 2 Issued: Revised: 1974-08-30 2006-09-06 V ac A Maximum "On" Time, s Maximum "On/Off" Ratio 240 480 600 240 480 600 450 375 300 540 450 360 10 10 10 10 10 10 10/90 10/90 10/90 10/90 10/90 10/90 42FE 42FE 42FE 42GE 42GE 42GE At the request of the manufacturer, these devices were tested for 250,000 operations, 3 phase, 3-pole (which covers 1 phase, 2-pole) controlling the following ampere loads with a power factor of 75 percent or higher. Cat. No. Maximum V ac A 16FE, 42FE 16GE, 42GE 600 600 75 90 PART WINDING At the request of the manufacturer, the open type devices were investigated for part winding applications where the maximum full-load and locked-rotor currents do not exceed those shown below. The devices were tested for 30,000 operations "making" the full-load current and "breaking" the locked-rotor current. The tests were conducted, 3 phase, 3-pole (covers 1 phase, 2-pole) at a rate of six operations per minute for the 240 V ratings and three operations per minute for the 480 and 600 V ratings. Cat. No. 16FE, 16FE, 16FE, 16GE, 16GE, 16GE, V ac 42FE 42FE 42FE 42GE 42GE 42GE Maximum Ratings FLA 240 480 600 240 480 600 LRA 75 75 75 90 90 90 450 375 300 540 450 360 Interlocks - Standard pilot duty, rated 600 V maximum. Alternate auxiliary snap switches manufactured by Micro Switch or Cherry Electric may be used provided they have a minimum rating of 1/4 hp, 10 A; 120 V and are die label Listed or Component Recognized (WJQR2). Short Circuit Current Ratings – These devices were tested for the following short-circuit current ratings. The ratings apply to all types of devices covered by this Report (contactors & starters) Protective Device + Current Cat. No. Suffix Voltage FE GE 600 600 Type/Max. Amp Rating Class J Fuse/200 Class J Fuse/200 Short-Circuit RMS Symmetrical Amperes 100,000 100,000 File E14900 Project 88NK12871 Issued: September 9, 1988 Revised: October 25, 2005 REPORT on COMPONENT - INDUSTRIAL CONTROL EQUIPMENT, MAGNETIC MOTOR CONTROLLERS (NLDX2) Siemens Energy & Automation, Inc. Norcross, GA Copyright C 1988 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. authorizes the above named company to reproduce that portion of this Report consisting of this Cover Page through Page 4. File E14900 Vol. 8 Vol. 11 Sec. 4 Sec. 2 and Report Page 1 Issued: Revised: 1988-09-09 2006-06-26 DESCRIPTION PRODUCT COVERED: USR, CNR – Component, Cat. No. 45 followed by C, D, E, F, or G, followed by D or G, followed by 10, followed by A or B, followed by E, F, G, H, J, L, S, or T (or X with a two-digit suffix) with or without Suffixes A, B, L, L1, L2, L3, L4, M or T with or without D8, with or without suffixes 70, 190 or 100R through 999R. Cat. No. 45 followed by C, D, E, F, or G, followed by D or G, followed by a six digit number, followed by R. GENERAL: These devices are single-pole, across-the-line magnetic motor controllers without overload relays, and are either open or enclosed. They are intended for use in air-conditioning and refrigeration equipment where the acceptability of the combination has been determined by Underwriters Laboratories Inc. RATING: These are maximum ratings. Lower ratings may be provided on controls with special suffixes, or suffix D5, or on controls which normally have a higher rating (e.g., 45EG could have the same ratings as 45DG). Cat. No. V ac FLA LRA Noninductive, A 45C (++) 240 20 120 25 277 20 110 25 480 20 100 25 600 20 80 25 45C-D8 240 20 120 30 277 20 120 30 480 20 100 30 600 20 100 30 45D 240 25 150 35 277 25 150 35 480 25 100 35 600 25 80 35 45D-D8 240 25 150 40 277 25 150 40 480 25 125 40 600 25 100 40 45E 240 30 180 40 277 30 180 40 480 30 150 40 600 30 120 40 (++) - Cat. No. 45CG devices may also have the same FLA/LRA ratings as the Cat. No. 45GG devices. File E14900 Vol. 8 Vol. 11 Cat. No. 45F FLA 35 35 35 35 40 40 40 40 45G V ac 240 277 480 600 240 277 480 600 LRA 180 180 150 120 240 240 200 160 Sec. 4 Sec. 2 and Report Page 1A Noninductive, A 50 50 50 50 55 55 55 55 Issued: Revised: 1988-09-09 2005-06-29 File E14900 Vol. 8 Vol. 11 Sec. 4 Sec. 2 and Report Page 2 Issued: Revised: 1988-09-09 2006-06-26 All noninductive ratings were tested for 250,000 operations to cover resistance heating applications. These devices may be used to control motors having inherent overheating protectors controlling the coil circuit of contactors. The contactors were additionally tested for use in applications where the stalled rotor test does not involve more than 6000 operations for the following ratings: Cat. No. 45C 45D 45E LRA 120 125 180 Maximum Minimum V ac On/Off Ratio 240 1/9 240 1/9 240 1/9 "On" Time 10 10 10 "Off" Time 90 90 90 Short Circuit Current Ratings – These devices were tested for the following short-circuit current ratings. Protective Device + Short-Circuit Current Cat. No. Suffix Voltage Type/Max. Amp Rating RMS Symmetrical Amperes CG DG EG FG GG 240 240 240 240 240 BQ3B/40 BQ3B/50 BQ3B/60 BQ3B/70 BQ3B/80 24,000 24,000 24,000 24,000 24,000 + - Siemens Listed Cat. No. BQ3B circuit breakers NOMENCLATURE A: They are designated: 45 C D 1 _ O A I II III IV V VI F _ VII DB VIII L1 IX 190 X I - Indicates basic device II - Indicates full load amperes C - 20 A D - 25 A E - 30 A F - 35 A G - 40 A III - Style D - Pre 1993 style G - 1993 style IV - Indicates number of normally open poles. V - Indicates number of normally closed poles. VI - Indicates provision of enclosure A - Open B - Type 1 enclosure Always 1. Always 0. File E14900 Project 89NK19403 Issued: November 9 , 1989 Revised: October 25, 2005 REPORT on COMPONENT - INDUSTRIAL CONTROL EQUIPMENT, MAGNETIC MOTOR CONTROLLERS Siemens Energy & Automation, Inc. Norcross, GA Copyright © 1989 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. authorizes the above named company to reproduce that portion of this Report consisting of this Cover Page through Page 4. File E14900 Vol. 8 Vol. 11 Sec. 2 Sec. 1 and Report Page 1 Issued: Revised: 1989-11-09 2006-01-23 DESCRIPTION PRODUCT COVERED: Definite purpose contactors, followed by A or G, followed by 20, H, J, L or T (or X with a two-digit L3, L4, M or T with or without 100R Cat. No. 45, followed by C, D, E, F or G, followed by A or B, followed by E, F, G, suffix) with or without B, D5, L1, L2, through 999R. Cat. No. 45 followed by C, D, E, F or G followed by A or G, followed by a six digit suffix number followed by R. GENERAL: These devices are open or enclosed type magnetically operated definite purpose contactors. They are intended to be used in heating, air conditioning, and refrigeration applications where the suitability of the combination has been determined by Underwriters Laboratories Inc. RATINGS: These are maximum ratings. Lower ratings may be provided on controls with special suffixes, or suffix D5, or on controls which normally have a higher rating (e.g., 45EG could have the same ratings as 45DG). All ratings are single-phase, per-pole. Additional 3-phase ratings are noted below. Cat. No. Voltage FLA LRA Resistive A 45C 277 480 600 20 20 20 120 100 80 30 30 30 45D 277 480 600 25 25 25 150 125 100 35 35 35 45E 277 480 600 30 30 30 180 135 110 40 40 40 45F 277 480 600 35 35 35 200 135 110 50 50 50 45G 277 480 600 40 40 40 240 200 160 55 55 55 File E14900 Vol. 8 Vol. 11 Sec. 2 Sec. 1 and Report Page 1A Issued: Revised: 1989-11-09 2006-06-26 The Cat. No. 45DG contactors may also have the same ratings as the Cat. No. 45EG contactors. The Cat. No. 45EG contactors also have a rating of 240 V ac, 31 fullload amps, 180 locked-rotor amps. All noninductive ratings were tested for 250,000 operations to cover resistance heating applications. The Cat. Nos. 45EG, 45FG and 45GG devices have been tested for ratings of 240 V ac, 55 A and 600 V ac, 50 A, breaking two legs of a three phase resistive load. The Cat. No. 45CG and 45DG devices have been tested for ratings 600 V ac, 35 A, breaking two legs of a three phase resistive load. These devices may be used to control motors having inherent overheating protectors controlling the coil circuit of contactors. Cat. No. LRA V ac 45C 120 277 On/Off Ratio Maximum "On" Time 1/9 10 Minimum "Off" Time 90 * Short Circuit Current Ratings – These devices were tested for the following short-circuit current ratings. Protective Device + Current Cat. No. Suffix Voltage CG DG EG FG GG 240 240 240 240 240 Type/Max. Amp Rating BQ3B/40 BQ3B/50 BQ3B/60 BQ3B/70 BQ3B/80 + - Siemens Listed Cat. No. BQ3B circuit breakers Short-Circuit RMS Symmetrical Amperes 24,000 24,000 24,000 24,000 24,000