WI-I/O 9-U2 inst_WI-IO 9-U2_1.5.vsd FCC Notice B This device complies with Part 15.247 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference and 2) This device must accept any interference received, including interference that may cause undesired operation Wavelengths 150 MHz 200 cm 450 MHz 66 cm 900 MHz = 33 cm 2.4 GHz = 13 cm 5 GHz = 6 cm A EXPANSION 1 Wavelength minimum 100M GND LINK ETHERNET USB RS232 Screw terminal to EARTH for surge protection BAT SUP SUP + + Enclosure Chassis Protective Surge Earth SUPPLY RJ-45 Ethernet Connection COLINEAR ANTENNA WEATHERPROOF CONNECTORS WITH “3M 23” TAPE SURGE ARRESTOR (OPTIONAL) - + 15-30V DC Supply RS232 Serial Port COAXIAL CABLE 0 + 485 RF 485 AI 1 AI 1 AI2 AI2 + - AI3 AI4 D1 D2 D3 D4 D5 D6 D7 D8 GND+24V + AO AO 1 2 GND+24V + + PROVIDE GOOD GROUND CONNECTION TO MAST, MODULE AND SURGE ARRESTOR MAST INSTALL ANTENNA ABOVE LOCAL OBSTRUCTIONS FOR MAXIMUM RADIO DISTANCE WI-I/O 9-U2 6720005011 IF GROUND CONDITIONS ARE POOR, INSTALL MORE THAN ONE STAKE EARTH terminal on bottom of module External battery if required RJ-45 Signal name 3 Data Terminal Ready Abbrev DB9 DTR 4 4 Signal Common GND 5 5 Receive Data RXD 2 6 Transmit Data TXD 3 For I/O Connections see Sheet 2 Side Access Panel Dip Switches WARNING - EXPLOSION HAZARD DO NOT DISCONNECT CIRCUITS WHILE LIVE, UNLESS AREA IS KNOWN TO BE NONHAZARDOUS Expansion I/O Power and RS485 serial connection NOTES · WI-I/O 9-U2 MODULES ARE SHIPPED FROM THE FACTORY AS MESHING RADIOS, FOR WIBNET COMPATIBILITY MODE IT WILL NEED TO BE ENABLED IN CONFIGURATION. · All connections must be SELV (Safety Extra Low Voltage <50V AC & <120V DC) · Ethernet Port wiring is that of a hub or switch. · EARTH terminal on end plate of module for surge protection. · DIO channels can be wired as either inputs or outputs. WI-I/O 9-U2 WI-I/O- EX-1-S-XX WI-I/O- EX-1-S-XX B A - + B A - + B A - + DIP 1 2 3 4 5 6 Description AI3 Current/Voltage AI3 Current/Voltage AI4 Current/Voltage AI4 Current/Voltage Unused Default Config Enable ON WI-I/O 9-U2 1 2 3 4 5 6 NOTE: “GND” and “SUP -“ terminals are connected internally to the EARTH terminal AI 1 AI 1 AI2 AI2 AO1 AO2 + - AI3 AI4 + D1 D2 D3 D4 D5 D6 D7 D8 GND+24V + + GND+24V Antenna Installation PWR MODULE RF 232 _ STRESS RELIEF LOOP 232 PWR 6720005011 WI-I/O 9-U2 inst_WI-IO 9-U2_1.5.vsd FCC Statutory Requirement Unlicensed operation limits the radio power. High gain aerials may only be used to compensate for cable losses. WI-I/O 9-U2 WI-I/O 9-U2 V+ Externally powered sensor TTL CMOS Output Single Ended Current Input (AI3&4) Differential Current Inputs (AI1&2) Digital Input WI-I/O 9-U2 Loop Powered Sensor ALS +24V DIO1 ON ALS +24V + 1 2 3 4 5 6 mA Voltage Free Contact AIN1+ + Power supply DIO2 Dip Switch setting for Current I/P - _ AIN1- AIN3 AIN2+ AIN4 DIO3 GND Loop powered sensor V- Power supply AIN2- + + Transistor Switch Device _ mA - GND Externally powered sensor V- WI-I/O 9-U2 WI-I/O 9-U2 WI-I/O 9-U2 ALS +24V ALS +24V AIN1+ + V DIO1 DIO2 DC Load + AOT1 AI AOT2 COM Max 30VDC 0.2A 0-25V Sensor Differential Voltage Inputs (AI1&2) AIN1- - Single Ended Voltage Input (AI3&4) AIN3 PLC 0-5VDC Sensor + + _ V- V- Single Ended Voltage Input Analog Output Digital Output GND AIN4 ON V GND - V- 1 - 2 3 4 5 6 Dip Switch setting for Voltage I/P GND GND WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT CIRCUITS WHILE LIVE, UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS V-