ULS200 Catalog Sheet

© Siemens AG 2016
Level Measurement
Point level measurement - Ultrasonic non-contacting switch
Pointek ULS200
■ Overview
■ Application
The measuring range for bulk solids is max. 3 m (9.8 ft) and 5 m
(16.4 ft) for liquids and slurries. Unlike invasive contacting devices, there is no material buildup on the sensor.
The level switch has a rugged design, combining the transducer
and electronics in one durable device. It has no moving parts
and is virtually maintenance-free.
The transducer, available in ETFE or PVDF copolymer, is inert to
most chemicals. This means the device can be used in the
chemical, petrochemical, water, and wastewater industries. A
sanitary version of the ULS200, with an industry standard flange
option, is easy to remove from the application for cleaning. It
thus satisfies the prerequisites for use in the food, beverage, and
pharmaceutical industries. The Pointek ULS200 delivers superior performance while reducing maintenance, downtime, and
equipment replacement costs.
• Key Applications: liquids, slurries, fluid materials, plugged
chute detection, chemical industry
4
The Pointek ULS200 is an ultrasonic non-contacting switch with
two switch points for level detection of bulk solids, liquids and
slurries in a wide variety of industries; ideal for sticky materials.
■ Benefits
• 2 switch outputs for high-high, high, low, and low-low level
alarms or pump up/pump down control
• Integral temperature compensation
• AC or DC power supply
• Electronics provided with fail-safe function
• Threaded and sanitary fitting clamp process connections
• Polycarbonate enclosure, Type 6/NEMA 6/IP67
• Easy, two-button programming
■ Design
Installation
The Pointek ULS200 should be mounted in an area that is within
the temperature range specified and that is suitable to the enclosure rating and materials of construction. The cover should be
accessible to allow programming, wiring and display viewing.
It is advisable to keep the Pointek ULS200 away from high
voltage or current runs, contactors and SCR control drives.
Locate the Pointek ULS200 so that it has a clear sound path
perpendicular to the material surface. The sound path should
not intersect the fill path, rough walls, seams, rungs etc.
Mounting and Interconnection
The Pointek ULS200 is available in three thread types: 2" NPT,
R 2" (BSPT), EN 10226 or PF2 and can be fitted with the optional
75 mm (3 inch) flange adapter for mating to 3" ASME, DN 65,
PN 10, and JIS 10K 3B sized flanges.
Separate cables and conduit may be required to conform to
standard instrumentation wiring or electrical codes.
4/128
Siemens FI 01 · 2016
© Siemens AG 2016
Level Measurement
Point level measurement - Ultrasonic non-contacting switch
Pointek ULS200
■ Configuration
■ Technical specifications
Mode of operation
Parabolic mounting
Measuring principle
Ultrasonic level switch
Measuring range
Measuring range in liquids
0.25 ... 5 m (0.8 ... 16.4 ft)
Measuring range in bulk solids
0.25 ... 3 m (0.8 ... 9.8 ft)
Output
AC Version (relay)
2 SPDT Form C contacts, rated 5 A at
250 V AC or 30 V DC, resistive load;
rated 1 A at 48 V DC resistive load
DC Version (relay)
2 SPDT Form C contacts,
rated 5 A at 30 V DC, resistive load;
rated 1 A at 48 V DC resistive load
DC Version (transistor)
2 switches, rated max. 100 mA, 48 V DC
4
Accuracy
AC/DC version
• Resolution
• Repeatability
3 mm (0.1 inch)
0.25 % of measuring range
Rated operation conditions
Flat mounting and Beam angle
Fill
Installation conditions
• Location
• Beam angle
Indoors/outdoors
12°
Ambient conditions
• Ambient temperature
• If mounted in metal threads
-40 ... +60 °C (-40 ... +140 °F)
-20 ... +60 °C (-5 ... +140 °F)
Medium conditions
• Process pressure
0.5 bar (7.25 psi) max.
Design
Pipe
Rungs
Material
Polycarbonate with gasket
Weight
Approx. 1.5 kg (3.3 lb)
Transducer material
PVDF or ETFE copolymer
Threaded mounting
2" NPT [(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226]
or G 2" [(BSPP), EN ISO 228-1]
For 3" ASME, DN 65, PN 10, and JIS 10
K3B
• Optional flange adapter
Seams
12°
Beam angle
Pointek ULS200 mounting
Sanitary mounting
4" sanitary fitting clamp
Power supply
AC version
100 ... 230 V AC, ± 15 %, 50/60 Hz,
max. 12 VA, 5 W
DC version
18 ... 30 V DC, 3 W
Displays and controls
Display
LCD, three digits, 9 mm (0.35 inch) high,
for display of distance between sensor
face and material, multi-segment graphic
for operating state
Memory
EEPROM, non-volatile
Programming
2 keys
Electronics/enclosure
Connection: terminal block,
max. 2.5 mm2 (14 AWG) solid/
1.5 mm2 (16 AWG) stranded
Degree of protection
IP67/Type 6/NEMA 6
Cable inlet
2 x ½" NPT or 2 x PG 13.5
Certificates and approvals
CE (EMC certificate available on
request), CSA US/C, FM
Siemens FI 01 · 2016
4/129
© Siemens AG 2016
Level Measurement
Point level measurement - Ultrasonic non-contacting switch
Pointek ULS200
■ Options
Flange adapter for mating 2" NPT or 2" BSP process connections to
3" ASME, DN 65 PN 10 and JIS 10K 3B flanges
Selection and Ordering data
Article No.
Pointek ULS200
Ultrasonic non-contacting switch with two switch
points for level detection of bulk solids, liquids and
slurries in a wide variety of industries; ideal for
sticky materials
7ML1510-
148.8 (5.86)
bolt hole circle
diameter
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Power supply
24 V DC, relay output
24 V DC, transistor output
100 ... 230 V AC, relay output
190.2 (7.49)
diameter
Pointek ULS200 optional flange adapter, dimensions in mm (inch)
4
777 0 7
 1
 2
 3
Approvals
CE, RCM, CSA Class I, II, Div. 21)
CE, RCM, CSAus/c, FM


Transducer/Process connection
ETFE, 2" NPT [(Taper), ANSI/ASME B1.20.1]
EFTE, R 2" [(BSPT), EN 10226]
EFTE, G 2" [(BSPP), EN ISO 228-1]



A
B
C
PVDF copolymer, 2" NPT [(Taper), ANSI/ASME B1.20.1] 
PVDF copolymer, R 2" [(BSPT), EN 10226]

PVDF copolymer, G [(BSPP), EN ISO 228-1]

E
F
G
PVDF copolymer, 4" sanitary mounting2)
J
Enclosure/cable inlet
Polycarbonate
• Cable inlet PG 13.5
• Cable inlet ½" NPT
1)
Available with Enclosure/cable inlet option 2 only
2)
Available with Approvals option K only
J
K


1
2
 We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol . For details see page 9/5 in the appendix.
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s)
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:  Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Operating Instructions
Article No.
Quick Start manual, multi-language
A5E32268616
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
Accessories
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosures
7ML1930-1AC
Universal Box Bracket Mounting Kit
7ML1830-1BK
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" NPT
7ML1830-1BT
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" BSPT
7ML1830-1BU
2" BSPT Locknut, plastic
7ML1830-1DQ
2" NPT Locknut
7ML1830-1DT
4" sanitary mounting clamp
7ML1830-1BR
Spare Parts
Polycarbonate Lid
7ML1830-1LG
 We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol . For details see page 9/5 in the appendix.
4/130
Siemens FI 01 · 2016
© Siemens AG 2016
Level Measurement
Point level measurement - Ultrasonic non-contacting switch
Pointek ULS200
■ Dimensional drawings
■ Schematics
Relay output
Threaded
1
60
(2.35)
Lid clip
#8-32x3/8"
machine screw
2
100 ... 230 V AC
50/60 Hz
74 (2.9)
57
(2.25)
L
N
1
2
+
-
3
4
5
6
7
8
9
Two Form ‘C’ (SPDT) relays can switch
external devices such as alarms, relays,
contactors, PLCs, DCSs, etc.
or
18 ... 30 V DC
Lid
4
Transistor output: DC version only
Conduit
connection
½" NPT or
PG 13.5
1
2
180 (7.1)
18 ... 30 V DC
+
2" NPT
R 2" BSPT
or PF2
Transducer
22 (0.87)
74 (2.9)
1
2
3
4
5
6
7
8
9
Two non-polarized transistor outputs are
suitable for connection to PLCs, DCSs,
or customer supplied relays.
Sanitary
Pointek ULS200 connections
180 (7.1)
74 (2.9)
Pointek ULS200, dimensions in mm (inch)
Siemens FI 01 · 2016
4/131