SITRANS LU180 Catalog Specification Sheet

© Siemens AG 2016
Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS LU180
■ Overview
■ Configuration
SITRANS LU180 is a short-range integrated ultrasonic level
transmitter. This intrinsically safe, 2 wire, 4 to 20 mA loop
powered transmitter is ideal for liquids, slurries, and bulk
materials in open or closed vessels to 5 m (16.4 ft).
■ Benefits
•
•
•
•
•
Easy to install, program, and maintain
Accurate and reliable
Sanitary models available
Patented Sonic Intelligence echo processing
Integral temperature compensation
■ Application
The transducer is available in PVDF copolymer, making the
device suitable for use in a wide variety of applications.
SITRANS LU180 is easy to install and maintain, and can be
quickly removed for cleaning as required by the food, beverage,
and pharmaceutical industries.
The reliability of the level data is based on the Sonic Intelligence
echo processing algorithms. A filter discriminates between
the true echo and false echoes from acoustic or electrical noises
and agitator blades in motion. The ultrasonic pulse propagation
time to the material and back is temperature-compensated and
converted into distance for display, analog output.
• Key Applications: chemical storage vessels, filter beds,
mud pits, liquid storage vessels, food applications
Fill
Pipe
Rungs
Seams
12º
Beam
Angle
SITRANS LU180 mounting
Siemens FI 01 · News 2016
4/1
© Siemens AG 2016
Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS LU180
■ Technical specifications
Mode of operation
Measuring principle
Ultrasonic level measurement
Input
Measuring range
0.25 ... 5 m (0.8 ... 16.4 ft)
Frequency
54 kHz
Selection and Ordering data
Article No.
SITRANS LU180
Short-range integrated ultrasonic level transmitter,
intrinsically safe, 2 wire, 4 to 20 mA loop powered
ideal for liquids, slurries, and bulk materials in open
or closed vessels to 5 m (16.4 ft).
7ML52020 77 0
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Transducer/Process connection
Output
4 ... 20 mA
mA
• Span
Proportional/
inversely proportional
600  in the loop at 24 V DC
• Max. load
Power supply
PVDF copolymer, 2" NPT
[(Taper), ANSI/ASME B1.20.1]
PVDF copolymer, R 2" [(BSPT), EN 10226]
PVDF copolymer, G 2" [(BSPP), EN ISO 228-1]
PVDF copolymer, 4" Sanitary mounting
Cable inlet
M20 x 1.5 (no cable gland included)
M20 x 1.5 [General Purpose cable gland
-20 ... +60 °C (-4 ... +140 °F) included]

E


F
G
J
Supply voltage
12 ... 30 V DC, 0.1 A surge
Max. power consumption
0.75 W (25 mA at 24 V DC)
Certificates and approvals
CSA:
IS/ Class I, II, III, Div. 1,
Groups: A, B, C, D, E, F, G T4
FM:
IS/ Class I, II, III, Div. 1,
Groups: A, B, C, D, E, F, G T4
ATEX:
II 1G Ex ia IIC T4 Ga
IECEx Ex ia IIC T4 Ga
NEPSI Ex ia II C T4 Ga
1/2" NPT stainless steel entry
(no cable gland included)
Stainless steel tag [13 x 45 mm
(0.5 x 1.75 inch)]: Measuring-point number/ identification (max. 20 characters) specify in plain text
Y15
Error in measurement
0.25 % of measuring range (in air)
3 mm (0.125 inch)
Test certificate: Manufacturer's test certificate
M to DIN 55350, Part 18 and to ISO 9000
C11
Resolution
Temperature
compensation
Built in
Operating Instructions
Article No.
English
A5E37100674
Echo processing
Sonic Intelligence
German
A5E37100685
12°
Note: Operating instructions should be ordered as a
separate line on the order
-40 ... +60 °C (-40 ... +140 °F)
-20 ... +60 °C (-4 ... +140 °F)
Normal atmospheric pressure
All literature is available to download for free, in a
range of languages, at
www.siemens.com/processinstrumentation/
documentation
1.3 kg (2.9 lb)
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
Accuracy
Rated operation conditions
Beam angle
Ambient temperature
• Standard
• Metallic mounting
Max. static operating pressure
Design
Weight
Material
• Electronics enclosure
• Transducer
Degree of protection
Process connection
Flange adapter
Cable inlet
PBT
PVDF copolymer
IP68 / NEMA 6 / TYPE 6
2" NPT
[(Taper), ANSI/ASME B1.20.1]
R 2" [(BSPT), EN 10226] or
G 2" [(BSPP), EN ISO 228-1]
3" Universal,
(fits DN 65, PN 10 and 3" ASME)
4" sanitary
1 inlet for M20, optional 1/2" NPT

Selection and Ordering data
A
B
C
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Accessories
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line
7ML1930-1AC
Universal box bracket mounting kit
7ML1830-1BK
Sanitary 4" mounting clamp
7ML1830-1BR
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" NPT
7ML1830-1BT
3" ASME, DN 65 PN 10, JIS 10K 3B ETFE Flange
adapter for 2" BSPT
7ML1830-1BU
2" NPT locknut, plastic
7ML1830-1DT
2" BSPT locknut, plastic
7ML1830-1DQ
Cable Gland, General Purpose
-20 ... +60 °C (-4 ... +140 °F)
A5E34457564
We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol . For details see page 9/5 in the appendix.
4/2
Siemens FI 01 · News 2016
© Siemens AG 2016
Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS LU180
■ Options
SITRANS LU180, Flange Adapter
The SITRANS LU180 can be fitted with the optional 75 (3)
flange adapter for mating to 3" ANSI, DIN 65 PN10 and
JIS 10K3B flanges.
SITRANS
LU180
Optional
flange
adapter
SITRANS LU180 optional flange adapter, dimensions in mm (inch)
Siemens FI 01 · News 2016
4/3
© Siemens AG 2016
Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS LU180
■ Dimensional drawings
SITRANS LU180, Threaded
53 (2.0)
91.5
(3.6)
Electronics
160.6 (6.3)
122.7 (4.8)
234.6 (9.2)
104.5 (4.1)
Mounting Thread
Sensor
87
(3.4)
SITRANS LU180, dimensions in mm (inch)
4/4
Siemens FI 01 · News 2016
83.3
(3.2)
© Siemens AG 2016
Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS LU180
SITRANS LU180, Sanitary
Electronics
239.2 (9.4)
Mounting
thread
73.0
(2.9)
Sensor
SITRANS LU180, dimensions in mm (inch)
Siemens FI 01 · News 2016
4/5
© Siemens AG 2016
Level Measurement
Continuous level measurement – Ultrasonic transmitters
SITRANS LU180
■ Schematics
SITRANS LU180, Threaded and sanitary models
Loop
instrumentation
R max
+
SITRANS
LU180
+ –
1 2
V Supply –
12 ... 30 V DC –
Display
Program
mode Alphanumeric
'20' key
Units
'4' key
Operation
status
LOE/fault
SITRANS LU180 connections
4/6
Siemens FI 01 · News 2016