ZL-2057-15

ZL-2057-15
Operating Voltage= 115/250 Vac
Maximum input voltage = 275 Vac
Operating Current Max= 15.0 amp
Operating Frequency= 115 Vac = 50—440 Hz
230Vac = 50 / 60 Hz
Operating Temperature = -20 TO 55C
Storage Temperature = -40 to 100C
Diel Withstand (Line to Case)= 1500V~ for 1 Min
Varistor Voltage activation = 354—429 volts
Leakage Current = 1.0 ma @ 230 Vac, 60 Hz
= 3.5 ma @ 115 Vac, 400 Hz
Gas tube activation = 425 volt minimum
Discharge after 1.0 sec.= 34 V
MTBF = 3,285,993 hours
USA
EUR
The ZL-2057-15 filter is configured to work with
the WESTCOR PFC MEGAPAC to meet MILSTD-461D,E or F. The filter has an integral MIL
connector for a secure, through-hole connection.
The filter is designed to meet the random vibration spec in accordance with Mil-Std 810F,
514.5, Procedure 1, General Vibration.
The filter is designed to meet the stresses encountered during shipment in accordance with
MIL-STD-8421F.
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
PH: 603 886-4100
JMK Ltd Glasgow Scotland UK PH: 44-(0) 7785310729
FX: 603 886-4115 email: [email protected]