Download

Modbus TCP/RTU Gateway
Hardware Installation Guide
for models
IE-GW-MB-2TX-1RS232/485
IE-GWT-MB-2TX-1RS232/485
Second Edition, June 2014
1516600000/01/06.14
Important note:
The detailed user manual, additional product information, tools
and any firmware update can be downloaded using following links:
http://www.weidmueller.com
► Select Product Catalogue
 Select „Industrial Ethernet active“
 Select „Modbus TCP/RTU Gateway“
 Select Product model
 Click and expand section „Downloads“
 Download needed software or documentation
► or alternatively:
Firmware and Tool „Modbus Gateway Administrator“ via…
 Select Downloads
 Select Software
 Select „Industrial Ethernet“
 Goto section Modbus TCP/RTU Gateway …
Documentation via…
 Select Downloads
 Select Print Media
 Select Manuals
 Goto section „Industrial Ethernet“
 Download „Manual-IE-GW-MB-2TX-1RS232/485…
Copyright Notice
2014 Weidmüller Interface GmbH & Co. KG
All rights reserved.
Reproduction without permission is prohibited.
Copyright
1. Overview
The Modbus gateways IE-GW-MB-2TX-1RS232/485 and IE-GWT-MB2TX-1RS232/485 (equipped with 1 serial port and 2 Ethernet ports)
convert between Ethernet-based Modbus TCP and serial-based
Modbus ASCII/RTU protocols. They can be used to allow Ethernet
masters to control serial slaves, or to allow a serial master to control
Ethernet slaves. Up to 16 TCP masters and 31 serial slaves can be
connected simultaneously.
2. Package Checklist
Before installing the Modbus TCP/RTU Gateway, verify that the
package contains the following items:
1 Modbus TCP/RTU Gateway
1 Hardware Installation Guide
If any of these items are missing or damaged, please contact your
Weidmüller customer service for assistance.
3. Hardware Description
LED Indicators
Name
PWR1
PWR2
Color
Red
Red
Function
Power is being supplied to the power input
Power is being supplied to the power input
Steady: Power is on and the unit is booting up
Red Blinking: IP conflict, DHCP or BOOTP server
did not respond properly, or a relay output
occurred
RDY
Steady: Power is on and the unit is functioning
Green normally
Blinking: Unit is responding to Locate function
Off
Power is off or power error condition exists
Orange 10 Mbps Ethernet connection
Ethernet
Green 100 Mbps Ethernet connection
1/2
Off
Ethernet cable is disconnected
Orange Serial port is receiving data
Green Serial port is transmitting data
P1
Off
Serial port is not transmitting or receiving data
Interfaces
1 Connector for dual input power and relay output
2 Ethernet Ports 10/100BaseT(X)
1 Terminal block for connecting serial Modbus devices with
RS422/RS485 interface or alternatively useable
1 Serial DB9 port (male) for connecting serial Modbus devices with
RS232 interface
Note: The serial ports may only be used alternatively, either the
RS232-DB9 or the RS422/485 connector can be used at one
time.
2
Reset Button
The reset button is used to load factory defaults. Use a pointed object
such as a straightened paper clip to hold the reset button down for five
seconds. Release the reset button when the Ready LED stops blinking.
Pin Assignments
10/100BaseT(X) Ethernet Port Connection
Pin
1
2
3
6
Signal
Tx+
TxRx+
Rx-
3
Serial Port RS232 (Male DB9)
Pin
1
2
3
4
5
6
7
8
9
RS-232
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
---
Serial Port RS485 / RS422 (Terminal Block)
Pin
1
2
3
4
5
RS-422/485 (4W)
TxD+(B)
TxD-(A)
RxD+(B)
RxD-(A)
GND
RS-485 (2W)
----Data+(B)
Data-(A)
GND
Power Input and Relay Output Pinouts
V2+
DC
Shielded
Power
Ground
Input 1
V2-
V1+
V1-
DC
Power
Input 1
DC
Power
Input 2
DC
Power
Input 2
Relay
output
Relay
output
Relais conditions:
Open when Power-off or when a relay-based alarm is triggered.
Closed when Power-on and no relay-based alarm is triggered.
4
DIP switches for RS422/485 line termination and setting pull
high/low resistors
The DIP switches (SW1) are located inside of the housing behind the
screwable side-gate.
To add a 120 Ω termination resistor, set switch 3 to ON. To disable the
termination resistor set switch 3 to OFF (default setting).
To set the pull high/low resistors to 150 KΩ, set switches 1 and 2 to
OFF (default setting).
To set the pull high/low resistors to 1 KΩ, set switches 1 and 2 to ON.
DIP switch 4 is reserved for future use.
ATTENTION
Do not use the 1 KΩ pull high/low setting ON the device
when using the RS-232 interface. Doing so will degrade the
RS-232 signals and reduce the effective communication
distance.
4. Hardware Installation Procedure
STEP 1: Use a standard Ethernet cable to connect the unit to an
Ethernet device or a network switch.
STEP 2: Connect your Modbus RTU/ASCII device to the
Gateway's serial port.
STEP 3: Mount the unit on a DIN-rail.
STEP 4: Connect the power source to power input.
5
5. Software-based Device Configuration
The Modbus TCP/RTU Gateway can be configured via one of the 2
Ethernet ports by
Integrated Webinterface
Telnet Console or
by PC-based utility “Modbus Gateway Administrator”
Accessing the Web interface:
The Web interface can be accessed via IP address 192.168.1.110 and
subnet mask 255.255.255.0 (Factory default value).
Connect the PC to one of the both Ethernet ports and set the PC’s IP
address to a free one of network range 192.168.1.0 / 255.255.255.0
Start a Web browser and enter the IP address of the connected
Gateway into the browser’s address line.
http://192.168.1.110
After the appearance of the login prompt, please enter following login
data (factory settings):
User name:
Password:
admin
Detmold
Configuration via PC-based tool “Modbus Gateway Administrator”:
1. Download the software from Weidmüller Internet page (Download
link see page 1).
2. Install the software according to attached installation guide
(contained in the ZIP-file).
3. Start the “Modbus Gateway Administrator” to configure the Modbus
TCP/RTU Gateway.
Note: For more detailed information about configuration and using the
Modbus TCP/RTU Gateway please read the downloadable manual from
Weidmüller Internet page (Download link see page 1).
6. Specifications
Power Requirements
Power Input
12 to 48 VDC
Max. 435 mA @ 12 VDC,
Power Consumption
Max. 130 mA @ 48 VDC
Physical Characteristics
Housing
Plastic, IP30
Dimensions
29 (W) x 124.5 (H) x 89.2(D) mm
Installation
DIN-Rail Mounting
6
Ethernet Interfaces
Ethernet ports
Magnetic isolation
protection (RJ45)
Serial Interfaces
Serial ports
Serial connector types
2 RJ45 ports 10/100BaseT(X), Auto
MDI/MDI-X
1.5 kV built-in
1
DB9 RS-232, 5-pin terminal block for
RS-422/485
Baud rate 50 bit/s to 921.6 kbit/s
ADDC® (automatic data direction
control)
15 KV ESD protection for all signals
Baudrates
RS-485 data direction
control
Serial line protection
Pull high/low resistor for
1 kOhm, 150 kOhm
RS-485
Terminating resistor for
120 Ohm
RS-485
Alarm Contact
1 relay output with a current capacity of
1 A @ 30 VDC
Relay Output
Relais conditions:
Open when Power-off or when a relaybased alarm is triggered.
Closed when Power-on and no relaybased alarm is triggered.
Environmental Limits
Operating Temperature
Operating Humidity
Regulary Approvals
EMC standards
Security
Hazardous Location
Free fall
Shock
Vibration
MTBF
Time
Database
WARRANTY
Time Period
0 to 55°C (32 to 131°F),
-40 to 75°C (-40 to 167°F) for –T model
-40 to 85 °C (-40 to 185 °F)
5 to 95% RH
FCC Part 15 Subpart B Class A
EN 55022 Class A
EN 61000-4-2 (ESD), Level 3
EN 61000-4-3 (RS), Level 3
EN 61000-4-4 (EFT), Level 4
EN 61000-4-5 (Surge), Level 3
EN 61000-4-6 (CS), Level 3
EN 61000-4-8
EN 61000-4-11
UL 508
UL/cUL Class 1 Div 2 Groups A, B, C, D
according to IEC 60068-2-32
according to IEC 60068-2-27
according to IEC 60068-2-6
210.794 hrs
Telcordia (Bellcore), GB
5 years
7
Weidmüller gives a 5 year warranty on this product in accordance with
the warranty terms as described in the general conditions of sale of the
Weidmüller company which has sold the products to you. Weidmüller
warrants to you that such products the defects of which have already
existed at the time when the risk passed will be repaired by Weidmüller
free of charge or that Weidmüller will provide a new, functionally
equivalent product to replace the defective one. Safe where expressly
described otherwise in writing in this catalogue/product description,
Weidmüller gives no warranty or guarantee as to the interoperability in
specific systems or as to the fitness for any particular purpose. To the
extent permitted by law, any claims for damages and reimbursement of
expenses, based on whatever legal reason, including contract or tort,
shall be excluded. Where not expressly stated otherwise in this
warranty, the general conditions of purchase and the expressive liability
commitments therein of the respective Weidmüller company which has
sold the products to you shall be applicable.
Contact Information
Weidmüller Interface GmbH & Co. KG
Postfach 3030
32760 Detmold
Klingenbergstraße 16
32758 Detmold
Germany
Phone +49 (0) 5231 14-0
Fax +49 (0) 5231 14-292083
E-Mail [email protected]
Internet www.weidmueller.com
8