Download

Solid State Relays
G3PA
CSM_G3PA_DS_E_3_2
Extremely Thin Relays Integrated with Heat
Sinks
• Downsizing achieved through optimum design of heat sink.
• Mounting possible via screws or via DIN track.
• Close mounting possible for linking terminals. (Except for G3PA260B-VD and G3PA-450B-VD-2.)
• Applicable with 3-phase loads.
• Replaceable power element cartridges.
• Comply with VDE 0160 (finger protection), with a dielectric
strength of 4,000 V between input and load.
• Certified by UL, CSA, and VDE (reinforced insulation).
Refer to Safety Precautions for All Solid State
Relays.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
■ Model Number Legend
G3PA-@@@@-@-@
1
2 3 4 5
6
7
1. Basic Model Name
G3PA: Solid State Relay
2. Rated Load Power Supply Voltage
2:
200 VAC
4:
400 VAC
3. Rated Load Current
10:
10 A
20:
20 A
30:
30 A
40:
40 A
50:
50 A
60:
60 A
4. Terminal Type
B:
Screw terminals
5. Zero Cross Function
Blank: Equipped with zero cross function
L:
Not equipped with zero cross function
6. Certification
VD: Certified by UL, CSA, and VDE
7. Special Specifications
Blank: Standard models
2:
480-V models
1
G3PA
Ordering Information
■ List of Models
Model
Isolation
G3PA-210B-VD
Phototriac
coupler
G3PA-220B-VD
Zero cross function
Yes
Indicator
Yes
Rated output load
10 A at 24 to 240 VAC
Rated input voltage
5 to 24 VDC
20 A at 24 to 240 VAC
G3PA-240B-VD
40 A at 24 to 240 VAC
G3PA-260B-VD
60 A at 24 to 240 VAC
G3PA-210BL-VD
No
10 A at 24 to 240 VAC
G3PA-220BL-VD
20 A at 24 to 240 VAC
G3PA-240BL-VD
40 A at 24 to 240 VAC
G3PA-260BL-VD
60 A at 24 to 240 VAC
G3PA-210B-VD
Yes
10 A at 24 to 240 VAC
G3PA-220B-VD
20 A at 24 to 240 VAC
G3PA-240B-VD
40 A at 24 to 240 VAC
G3PA-260B-VD
60 A at 24 to 240 VAC
G3PA-420B-VD
20 A at 180 to 400 VAC
G3PA-430B-VD
30 A at 180 to 400 VAC
G3PA-420B-VD-2
20 A at 200 to 480 VAC
G3PA-430B-VD-2
30 A at 200 to 480 VAC
G3PA-450B-VD-2
50 A at 200 to 480 VAC
24 VAC
12 to 24 VDC
Note: When ordering, specify the rated input voltage.
Replacement Parts
Name
Carry current
Power Device
Cartridge
10 A
Load voltage range
19 to 264 VAC
20 A
40 A
60 A
20 A
150 to 440 VAC
30 A
20 A
180 to 528 VAC
Model
Applicable SSR
G32A-A10-VD DC5-24
G3PA-210B-VD DC5-24
G32A-A10L-VD DC5-24
G3PA-210BL-VD DC5-24
G32A-A10-VD AC24
G3PA-210B-VD AC24
G32A-A20-VD DC5-24
G3PA-220B-VD DC5-24
G32A-A20L-VD DC5-24
G3PA-220BL-VD DC5-24
G32A-A20-VD AC24
G3PA-220B-VD AC24
G32A-A40-VD DC5-24
G3PA-240B-VD DC5-24
G32A-A40L-VD DC5-24
G3PA-240BL-VD DC5-24
G32A-A40-VD AC24
G3PA-240B-VD AC24
G32A-A60-VD DC5-24
G3PA-260B-VD DC5-24
G32A-A60L-VD DC5-24
G3PA-260BL-VD DC5-24
G32A-A60-VD AC24
G3PA-260B-VD AC24
G32A-A420-VD DC12-24
G3PA-420B-VD DC12-24
G32A-A430-VD DC12-24
G3PA-430B-VD DC12-24
G32A-A420-VD-2 DC12-24
G3PA-420B-VD-2 DC12-24
30 A
G32A-A430-VD-2 DC12-24
G3PA-430B-VD-2 DC12-24
50 A
G32A-A450-VD-2 DC12-24
G3PA-450B-VD-2 DC12-24
VDE
certification
Yes
■ Other Units (Order Separately)
Units that Enable 2-line Switching of 3-phase Power
Name
Short-circuit Unit
Current flow
10 A
Model
G32A-D20
20 A
30 A
Applicable SSR
G3PA-210B-VD, G3PA-210BL-VD
G3PA-220B-VD, G3PA-220BL-VD
G3PA-420B-VD, G3PA-420B-VD-2
G32A-D40
40 A
G3PA-430B-VD, G3PA-430B-VD-2
G3PA-240B-VD, G3PA-240BL-VD
Note: Refer to List of Certified Models for a list of products that comply with safety standards.
2
G3PA
Specifications
■ Ratings (at an Ambient Temperature of 25°C)
Input
Model
G3PA-210B-VD
Rated voltage
Operating Voltage
range
Input current
impedance
Voltage level
Must operate voltage
Must release voltage
5 to 24 VDC
4 to 30 VDC
7 mA max.
4 VDC max.
1 VDC min.
5 to 24 VDC
4 to 30 VDC
20 mA max.
4 VDC max.
1 VDC min.
24 VAC
19.2 to 26.4 VAC
1.4 kΩ±20%
19.2 VAC max.
4.8 VAC min.
12 to 24 VDC
9.6 to 30 VDC
7 mA max.
9.2 VDC max.
1 VDC min.
G3PA-220B-VD
G3PA-240B-VD
G3PA-260B-VD
G3PA-210BL-VD
G3PA-220BL-VD
G3PA-240BL-VD
G3PA-260BL-VD
G3PA-210B-VD
G3PA-220B-VD
G3PA-240B-VD
G3PA-260B-VD
G3PA-420B-VD
G3PA-430B-VD
G3PA-420B-VD-2
G3PA-430B-VD-2
G3PA-450B-VD-2
Output
Model
Rated load voltage
Load voltage range
Load current
Inrush current
G3PA-210B(L)-VD
24 to 240 VAC (50/60 Hz) 19 to 264 VAC (50/60 Hz) 0.1 to 10 A at 40°C
G3PA-220B(L)-VD
0.1 to 20 A at 40°C
220 A (60 Hz, 1 cycle)
G3PA-240B(L)-VD
0.5 to 40 A at 40°C
440 A (60 Hz, 1 cycle)
G3PA-260B(L)-VD
0.5 to 60 A at 40°C
G3PA-420B-VD
180 to 400 VAC (50/60 Hz) 150 to 440 VAC (50/60 Hz) 0.5 to 20 A at 30°C
G3PA-430B-VD
0.5 to 30 A at 30°C
VDRM
(reference value)
150 A (60 Hz, 1 cycle) 600 V (VDRM)
440 A (60 Hz, 1 cycle)
220 A (60 Hz, 1 cycle) 1,000 V (VDRM)
440 A (60 Hz, 1 cycle)
G3PA-420B-VD-2
200 to 480 VAC (50/60 Hz) 180 to 528 VAC (50/60 Hz) 0.5 to 20 A at 30°C
220 A (60 Hz, 1 cycle) 1,200 V (VDRM)
G3PA-430B-VD-2
0.5 to 30 A at 30°C
440 A (60 Hz, 1 cycle)
G3PA-450B-VD-2
0.5 to 50 A at 30°C
440 A (60 Hz, 1 cycle)
Refer to Engineering Data for further details.
3
G3PA
■ Characteristics
Item
G3PAG3PA210B(L)-VD 220B(L)-VD
G3PA240B(L)-VD
G3PA260B(L)-VD
G3PA420B-VD
G3PA420B-VD-2
G3PA430B-VD
G3PAG3PA430B-VD-2 450B-VD-2
Operate time 1/2 of load power source cycle + 1 ms max. (DC Input, -B models)
1 1/2 of load power source cycle + 1 ms max. (AC Input)
1 ms max. (-BL models)
Release time 1/2 of load power source cycle + 1 ms max. (DC Input)
1 1/2 of load power source cycle + 1 ms max. (AC Input)
Output ON
voltage drop
1.6 V (RMS) max.
Leakage
current
5 mA max. (at 100 VAC)
10 mA max. (at 200 VAC)
10 mA max. (at 100 VAC)
20 mA max. (at 200 VAC)
20 mA max. 20 mA max.
(at 400 VAC) (at 480 VAC)
20 mA max. 20 mA max. (at 480 VAC)
(at 400 VAC)
I2 t
260 A2s
1,260 A2s
260 A2s
1,800 A2s
Insulation
resistance
100 MΩ min. (at 500 VDC)
Dielectric
strength
4,000 VAC, 50/60 Hz for 1 min
Vibration
resistance
Destruction: 10 to 55 to 10 Hz, 0.375–mm single amplitude (Mounted to DIN track)
Shock
resistance
Destruction: 300 m/s2 (mounted to DIN track)
Ambient
temperature
Operating: –30°C to 80°C (with no icing or condensation)
Storage: –30°C to 100°C (with no icing or condensation)
Certified
standards
UL508, CSA C22.2 (No.14, No.950), EN60950-1 File No. UL508,
5915ÜG
CSA C22.2
(No.14),
EN60947-4-3
File No.
6642ÜG
EMC
Emission: EN55011 Group 1 Class A
Immunity: EN61000-6-2
Ambient
humidity
Operating: 45% to 85%
Weight
Approx.
260 g
Approx.
340 g
1.8 V (RMS) max.
Approx.
460 g
Approx.
900 g
Approx.
290 g
1,800 A2s
1,800 A2s
UL508,
CSA C22.2
(No.14),
EN60947-4-3
File No.
133127ÜG
UL508,
UL508, CSA C22.2
CSA C22.2 (No.14), EN60947-4-3
(No.14),
File No. 133127ÜG
EN60947-4-3
File No.
6642ÜG
Approx.
290 g
Approx.
410 g
Approx.
410 g
Approx.
900 g
4
G3PA
Operation
■ Replacement Parts
G32A-A Power Device Cartridge
The G32A-A Power Device Cartridge (a Triac Unit) can be replaced with a new one. When the temperature indicator has changed from pink to red,
the triac circuitry may have malfunctioned possibly by an excessive flow of current, in which case, dismount the damaged cartridge for replacement.
The damaged cartridge can be replaced with a new one without disconnecting the wires from the G3PA.
Improve the heat radiation efficiency of the G3PA before replacing the cartridge.
The G32A-A Power Device Cartridge can withstand an excessive current for a short period of time, such as may be caused accidentally by the
short circuitry of the load, in which case the temperature indicator will not turn red.
Be sure to turn OFF the power supply when replacing the Cartridge. Supplying power with the Cartridge removed may result in malfunction.
To remove or replace the Power Device Cartridge for the G3PA-210B-VD, G3PA-220B-VD, or G3PA-420B-VD(-2), use the special tool provided
with it for extraction. (No special tool is required for other models.)
The G3PA can be broadly divided into two series: Previous models and models with model numbers that end with "-VD." The Cartridge shown at
the right cannot be mounted to models in the G3PA-@@@B-(-US) Series.
Appearance
G32A-A10(L)-VD G32A-A20(L)-VD
G32A-A420-VD(-2)
G32A-A40(L)-VD
G32A-A430-VD(-2)
G32A-A60(L)-VD
G32A-A450-VD-2
Replacing Power Device Cartridges
When replacing Power Device Cartridges, use the specified model. Using a Power Device Cartridge other than the specified one will result in faulty
operation and destruction of the elements.
5
G3PA
■ Replacement Procedure
G32A-A10(L)-VD/G32A-A20(L)-VD/G32-A420-VD(-2)
To remove or replace the Power Device Cartridge, use the special tool provided with it for extraction.
(Do not switch on the power without the Power Device Cartridge. For details, see the attached the instruction sheet with the product.)
Extraction
Follow the procedures below to dismount the Power Device
Cartridge from the G3PA.
1. Switch off the power.
2. Remove the terminal cover.
3. Hook the indented part of the cartridge with the tool and pull up
on the cartridge to remove it.
Remover
Hook here with
Remover.
Apply silicone grease here.
2. Make sure that there is no dust or pieces of wire on the heat sink
of the G32A-A or the G3PA.
3. Insert the cartridge into the opening of the G3PA so that the
letters on the cartridge and those on the G3PA are in the same
direction and side A and side B are even.
Side A
Side B
Mounting
Follow the procedures below to mount the Power Device Cartridge
on the G3PA.
1. Apply silicone grease (provided with the G32A-A) to the entire
surface of the heat sink.
4. Attach the terminal cover.
5. Switch on the power and check the G3PA to be sure it works
properly.
G32A-A40(L)-VD/G32A-A60(L)-VD/G32A-A430-VD(-2)/G32A-A450-VD-2
The G32A Power Device Cartridge is mounted and secured with screws to the G3PA Unit. No special tool is required to remove the Cartridge.
Extraction
Mounting
Follow the procedures below to dismount the G32A-A Power Device
Cartridge from the G3PA.
1. Apply silicone grease to the entire surface of the heat sink.
1. Switch off the power.
2. Remove the terminal cover.
3. Loosen the two centered screws on the sides to dismount the
cartridge. The screws are connected to terminals 1 and 2.
Apply silicone grease here.
Loosen
2. Make sure that there is no dust or pieces of wire on the heat sink
of the G32A-A or the G3PA.
Loosen
4. Loosen the screws on both the corners.
Loosen
Loosen
5. Hold the indented part of both the corners to dismount the
cartridge.
6
G3PA
3. Insert the cartridge into the opening of the G3PA so that side A
and side B are even.
Side A
4. Tighten the screws on both the corners with a tightening torque of
0.59 to 0.78 N·m.
5. Tighten the screws on both the sides with a tightening torque of
0.59 to 0.78 N·m.
6. Attach the terminal cover.
7. Switch on the power and check the G3PA to be sure it works
properly.
Side B
■ Linking Terminal Connection
• Connecting with linking terminal for G3PA-210B(L)-VD, -220B(L)VD, -240B(L)-VD and G3PA-420B-VD(-2), G3PA-430B-VD(-2).
SSR1
SSR2
SSR1
• Connecting with linking terminal for G32A.
SSR
G32A Unit
SSR
G32A Unit
SSR2
*
* The cover will not fit if
the terminal protrudes.
1. When SSRs are close
mounted, loosen the
M3.5 Sems screw and
flip the linking terminal
down.
2. Insert the linking
terminal securely
into the center of
the screw and
tighten the screw.
1. When SSR are close
mounted, loosen the
M3.5 Sems screw on
the G32A and flip the
linking terminal down.
2. Insert the linking terminal
securely into the center
of the screw and tighten
the screw. Ensure that
the linking terminal does
not protrude.
Connect the terminal with power off.
Linking terminal
G3PA-420B-VD
Refer to the instruction manual for
the G32A-A Power Device Cartridge
to replace the G3PA's triac part.
Linking terminal
When the temperature indicator has turned from pink to red, the G32-A-A Power Device Cartridge
may have malfunctioned, in which case the cartridge must be replaced with a new one.
Linking
terminal
Linking
terminal
Use the terminal cover to prevent accidents
due to electric shock.
7
G3PA
Engineering Data
Load Current vs. Ambient Temperature
Vertical Mounting
Panel
Ground
G3PA-210B(L)-VD, G3PA-220B(L)-VD
G3PA-240B(L)-VD
G3PA-260B(L)-VD
G3PA-220B(L)-VD
80
15
Load current (A)
G3PA-210B(L)-VD
Load current (A)
Load current (A)
25
60
40
25
20
-30 -20
Ambient temperature (°C)
Ambient temperature (°C)
0
20
40
60
80
100
Ambient temperature (°C)
For close mounting of two or three SSRs, limit the load current to 90% or less.
Ambient temperature (°C)
G3PA-450B-VD-2
Load current (A)
G3PA-430B-VD, G3PA-430B-VD-2
Load current (A)
Load current (A)
G3PA-420B-VD, G3PA-420B-VD-2
Ambient temperature (°C)
Ambient temperature (°C)
For close mounting of two or three SSRs, limit the load current to 80% or less.
8
G3PA
Input Voltage vs. Input Current
G3PA-4@0-VD, G3PA-4@-VD-2
Input impedance (kΩ)
Input current (mA)
Input impedance (kΩ)
Input current (mA)
G3PA-2@0B-VD
Ta = 25°C
8
6
4
Input current
2
1
0.8
0.6
Input impedance
10
Input
current
4
2
Input impedance
1
0.8
0.6
0.4
0.4
0.2
0.2
0.1
1
T = 25°C
8
6
0.1
2
4
6
8 10
20
1
40
2
4
6
8 10
20
40
Input voltage (V)
Input voltage (V)
Horizontal Mounting
Panel
Ground
G3PA-220B(L)-VD
15
14
11
10
G3PA-210B(L)-VD
7
5.5
5
3.5
G3PA-260B(L)-VD
Load current (A)
20
G3PA-240B(L)-VD
Load current (A)
Load current (A)
G3PA-210B(L)-VD, G3PA-220B(L)-VD
28
11
10
60
42
40
20
18
−30 −20
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
40
60
80
100
Load current (A)
Load current (A)
G3PA-420B-VD
20
G3PA-450B-VD-2
G3PA-420B-VD, G3PA-430B-VD
G3PA-420B -VD-2, G3PA-430B-VD-2
G3PA-430B-VD
0
Ambient temperature (°C)
Ambient temperature (°C)
9
G3PA
Close Mounting (Up to Three)
Panel
Ground
DIN track
G3PA-210B(L)-VD, G3PA-220B(L)-VD
G3PA-240B(L)-VD
G3PA-260B(L)-VD
30
45
27
G3PA-220B-VD
15
13
9
G3PA-210B-VD
7
5
4.5
64
36
Load current (A)
20
18
Load current (A)
Load current (A)
40
30
20
14
48
40
20
10
-30 -20
Ambient temperature (°C)
Ambient temperature (°C)
G3PA-420B-VD, G3PA-420B-VD-2
20
40
60
80
100
Ambient temperature (°C)
G3PA-430B-VD, G3PA-430B-VD-2
30
40
Load current (A)
Load current (A)
0
20
16
10
30
24
20
10
−30
10
30
80
Ambient temperature (°C)
100
−30
10
30
80
Ambient temperature (°C)
Load current (A)
G3PA-450B-VD-2
Ambient temperature (°C)
10
G3PA
One Cycle Surge Current: Non-repetitive
Note: Keep the inrush current to half the rated value if it occurs repetitively.
Energized time (ms)
G3PA-240B(L)-VD/260B(L)-VD,
G3PA-430B-VD, G3PA-430B-VD-2,
G3PA-450B-VD-2
Inrush current (A. Peak)
G3PA-220B(L)-VD, G3PA-420B-VD,
G3PA-420B-VD-2
Inrush current (A. Peak)
Inrush current (A. Peak)
G3PA-210B(L)-VD
Energized time (ms)
Energized time (ms)
11
G3PA
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3PA-210B(L)-VD
With Terminal
Cover
Without Terminal
Cover
4.6 dia.
Two, M4
Linking terminal B1
Mounting
Holes
Terminal
Arrangement/
Internal Connections
Two, 4.5 dia. or M4 holes
Input circuit
Trigger circuit
Two,
M3.5
Linking
terminal B2
4.6 x 5.6 elliptical
hole
100 max.
G3PA-220B(L)-VD
Without Terminal
Cover
With Terminal
Cover
4.6 dia.
Linking terminal B1
Mounting
Holes
Two, M4
Terminal
Arrangement/
Internal Connections
Two, 4.5 dia. or M4 holes
Input circuit
Trigger circuit
Two,
M3.5
Linking terminal B2
4.6 x 5.6 elliptical
hole
100 max.
Linking
terminal B1
With Terminal
Cover
4.6 dia.
Two, M5
Mounting
Holes
Two, 4.5 dia. or M4 holes
Two,
M3.5
Terminal
Arrangement/
Internal Connections
Input circuit
Without Terminal
Cover
Trigger circuit
G3PA-240B(L)-VD
Linking
terminal B2
4.6 x 5.6 elliptical
hole
100 max.
12
G3PA
With Terminal
Cover
Without Terminal
Cover
Terminal Arrangement/
Internal Connections
Mounting Holes
4.6 dia.
Two, M5
Two, 4.5 dia.
or M4 holes
Two, M3.5
G3PA-260B
-VD
1
G3PA-450B
-VD-2
1
+
+
Trigger circuit
A1
Input circuit
Trigger circuit
A1
A2
4.6 x 5.6
elliptical hole
2
110 max.
Input circuit
G3PA-260B(L)-VD
G3PA-450B-VD-2
A2
−
2
−
100 max.
G3PA-420B-VD, G3PA-420B-VD-2
Without Terminal
Cover
With Terminal
Cover
Mounting Holes
Two, 4.5 dia. or M4
4.6 dia.
Terminal Arrangement/
Internal Connections
Two, M4
7.6
Linking
terminal
−B2
90±0.3
80
Trigger circuit
38 100
max.
Input circuit
90±0.2
Linking
terminal
67 +B1
8.6
Two, M3.5
2.2
8.8
25±0.2
4.5 x 5.6 elliptic hole
100 max.
37 max.
4.5
13.2
91
90
G3PA-430B-VD, G3PA-430B-VD-2
Without Terminal
Cover
With Terminal
Cover
Mounting Holes
Terminal Arrangement/
Internal Connections
4.6 dia.
Two, M5
Two, 4.5 dia. or M4
Linking
terminal
+B1
100
38 max.90±0.2 80
90±0.3
Linking
terminal
−B2
Input circuit
67
Trigger circuit
7.6
13
18
13
4.6 x 5.6
elliptic hole
89
35±0.2
4.5
100 max.
47 max.
35±0.3
91
13
G3PA
Safety Precautions
■ Precautions for Correct Use
Load
Please observe the following precautions to prevent failure to
operate, malfunction, or undesirable effect on product performance.
Load Connection
Load power
supply
SSR
Input
When attaching a heat sink to the G3PA-(VD), in order to facilitate
heat dissipation, apply silicone grease or equivalent heat-conductive
grease on the heat sink. (Toshiba Silicone, Shinetsu Silicone, etc.)
For an AC load, use a power supply rated at 50 or 60 Hz.
The maximum operating frequency is 10 Hz.
The G3PA-(VD) has a built-in varistor for overvoltage protection.
Tighten the mounting screws of the heat sink with a torque of 0.78 to
0.98 N·m.
At a low applied voltage, such as 24 VAC, the load current is not fully
supplied. When the Unit is switched ON, the voltage required to
power the Unit deprives the output signal of the necessary voltage
level and thus creates loss time. The lower the load voltage is, the
greater the loss time is. This condition, however, will not create any
serious problems.
Noise Terminal Voltage according to
EN55011
The G3PA-(VD) complies with EN55011 standards when a capacitor
is connected to the load power supply as shown in the following
circuit diagram.
Load
Input
G3PA-(VD)
Output
Loss time
Recommended Capacitor: 1 µF, 250 VAC
For a DC or L load, a diode should be connected in parallel the load
to absorb the counter electromotive force of the load.
Mounting
Vertical
• Screw or DIN track mounting is possible.
• Vertical mounting should usually be used.
Vertical mounting
Vertical
Panel
DIN track
G3PA
Vertical
The rated ambient
temperature is
40°C. (30°C for
400 V.)
G3PA
80 mm
DIN track
Close mounting
• Close mounting cannot be used if the SSR is used at a 100% load
current. Leave a gap of at least 10 mm on the left and right of each
Unit.
• Close mounting can be used under the following conditions:
1. Close mounting can be performed with no more than three SSRs
(For four or more SSRs, leave a gap of at least 10 mm.)
2. Use a load current of 80% or less (90% or less for the
G3PA-210B-VD, G3PA-220B-VD, or G3PA-240B-VD).
3. Leave a gap of at least 80 mm above and below the SSR.
4. Leave a gap of at least 60 mm from wiring ducts to the top of the
SSR and at least 30 mm from wiring ducts to the bottom of the SSR.
• With vertical mounting, reduce the load current by 30%.
(Refer to the Load Current vs. Ambient Temperature graph.)
Horizontal mounting
Panel
Note: Leave a distance of 60 mm min. between SSRs and ducts (especially above the SSR).
14
G3PA
Close Mounting
A heat exchanger, if used, should be located in front of the SSR Units
to ensure the efficiency of the heat exchanger.
SSR Mounting Pitch
Please reduce the ambient temperature of SSRs.
Panel Mounting (At a rated ambient temperature of 40°C).
The rated load current of an SSR is measured at an ambient
temperature of 25 or 40 °C.
Duct or airflow obstruction
SSR
An SSR uses a semiconductor in the output element. This causes
the temperature inside the control panel to increase due to heating
resulting from the passage of electrical current through the load. To
restrict heating, attach a fan to the ventilation outlet or air inlet of the
control panel to ventilate the panel. This will reduce the ambient
temperature of the SSRs and thus increase reliability. (Generally,
each 10°C reduction in temperature will double the expected life.)
60 mm min.
Between duct
or airflow
obstruction
and SSR
Mounting direction
Vertical direction
Load current (A)
30 mm min.
80 mm min.
Space between
SSRs
10 A
Required number of fans 0.16
per SSR
20 A
0.31
30 A
0.47
40 A
0.62
60 A
0.93
Example: For 10 SSRs with load currents of 20 A,
0.31 x 10 = 3.1
Thus, 4 fans would be required.
Close Mounting
min.
Size of fans: 92 mm2, Air volume: 0.7 m3/min,
Ambient temperature of control panel: 30°C
If there are other instruments that generate heat in the control
panel other than SSRs, additional ventilation will be required.
Relationship between SSRs and Ducts
Countermeasure (1)
Duct Height
Countermeasure (2)
50 mm max.
Vertical
direction
(A height of no
more than half
the SSR's height is
recommended.)
G3PA
G3PA
Mounting surface
G3PA
Mounting surface
Mounting surface
Duct or
airflow
obstruction
Airflow
Duct or
airflow
obstruction
Do not surround the SSR
with ducts, otherwise the
heat radiation of the SSR
will be adversely affected.
Use short ducts.
If the ducts cannot be
shortened, place the SSR
on a metal base so that it
is not surrounded by the
ducts.
Ventilation
Be aware of air flow
Duct or
air flow
obstruction
Ventilation
outlet
G3PA
G3PA
G3PA
Air inlet
If the air inlet or air outlet has a filter, clean the filter regularly to
prevent it from clogging and ensure an efficient flow of air.
Do not locate any objects around the air inlet or air outlet, otherwise
the objects may obstruct the proper ventilation of the control panel.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
In the interest of product improvement, specifications are subject to change without notice.
15
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
 Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
 Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
 Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.8
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.