Download

Built-in Power Supply Photoelectric Sensor
E3JM
CSM_E3JM_DS_E_11_4
Model Contribute to Overall Cost
Reduction
E3JM Terminal Block Models
• Easy to wire and adjust.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on
page 7.
Ordering Information
Sensors (Refer to Dimensions on page 9.)
Red light
Sensing
method
Appearance
Connection
method
Operation
mode
Sensing distance
Output
Functions
configuration
--Relay
Timer
Throughbeam
(Emitter +
Receiver) *
10 m
Light-ON
Dark-ON
(switch
selectable)
Terminal
block
Retroreflective
with MSR
function
--DC SSR
Timer
Relay
--Timer
4m
DC SSR
E39-R1 (provided)
--Timer
Relay
Diffusereflective
--Timer
700 mm
DC SSR
--Timer
Infrared light
Model
E3JM-10M4-N
Emitter: E3JM-10L-N
Receiver: E3JM-10DM4-N
E3JM-10M4T-N
Emitter: E3JM-10L-N
Receiver: E3JM-10DM4T-N
E3JM-10S4-N
Emitter: E3JM-10L-N
Receiver: E3JM-10DS4-N
E3JM-10S4T-N
Emitter: E3JM-10L-N
Receiver: E3JM-10DS4T-N
E3JM-R4M4
E3JM-R4M4T
E3JM-R4S4
E3JM-R4S4T
E3JM-DS70M4
E3JM-DS70M4T
E3JM-DS70S4
E3JM-DS70S4T
*Through-beam Sensors are sold in sets that include both the Emitter and Receiver.
Note: UL-listed models have the -US suffix. The model number for an E3JM Through-beam Sensor ends in “-US” (and not in “-N”). (Example: E3JM-10M4-US).
Tightening nuts, washers, and rubber bushings are not provided with these models.
Change: Shape of the E3JM conduit socket
Accessories (Order Separately)
Slit (A Slit is not provided with the Sensor for through-beam. Order a Slit separately if required.) (Refer to Dimensions on page 9.)
Slit width
1 mm × 20 mm
Sensing distance
E3JM-10@4(T)-N
Minimum detectable object
(reference value)
1.2 m
1-mm dia.
Model
E39-S39
Quantity
Remarks
1 Slit each for
(Seal-type long slit)
the Emitter and
Can be used with the E3JM-10@4(T)-N
Receiver (2 Slits
Models.
total)
Reflectors (A Reflector is required for each Retro-reflective Sensor.)
The E39-R1 Reflector is provided with the Sensor. Order other Reflectors separately if required. (Refer to Dimensions on E39-L/E39-S/E39-R.)
Name
Reflectors
Sensing distance
E3JM-R4@4(T)
Model
4m
E39-R1
Quantity
1
Remarks
Provided with the E3JM-R4@4(T)
Note: Refer to Reflectors on E39-L/E39-S/E39-R for details.
1
E3JM
Mounting Bracket
Some Mounting Brackets are provided with the Sensor. Order other Mounting Brackets separately if required. (Refer to E39-L/E39-S/E39-R)
Appearance
Model
Quantity
Remarks
E39-L53
1
Provided with the E3JM.
E39-L51
1
Mounting Bracket designed for changing
from he E3A-M, E3A2, E3A3, OA-5, or
OA-5N to the E3JM.
Note: 1. When using a Through-beam Sensor, order one Connector for the Receiver and one for the Emitter.
2. Refer to Mounting Brackets on E39-L/E39-S/E39-R for details.
2
E3JM
Ratings and Specifications
Sensing method
Item
Model
Through-beam model
Retro-reflective model
(with MSR function)
Diffuse-reflective model
E3JM-10@4(T)-N
E3JM-R4@4(T)
E3JM-DS70@4(T)
Sensing distance
10 m
4 m (When using E39-R1)
Standard sensing object
Opaque: 14.8-mm dia. min.
Opaque: 75-mm dia. min.
Differential travel
---
Directional angle
Both Emitter and Receiver 3° to
20°
1° to 5°
Light source (wavelength)
Infrared LED (950 nm)
Red LED (660 nm)
Power supply voltage
12 to 240 VDC±10%, ripple (p-p): 10% max.
24 to 240 VAC±10%, 50/60 Hz
Power consumption
DC
3 W max. (Emitter 1 W max.
Receiver 2 W max.)
2 W max.
AC
3 W max. (Emitter 1 W max.
Receiver 2 W max.)
2 W max.
Response time
--20% max. of sensing distance
--Infrared LED (950 nm)
Relay output (E3JM-@@M4 (T) model): SPDT, 250 VAC, 3A (cosφ=1) max., 5 VDC, 10 mA min.
DC SSR output (E3JM-@@S4 (T) model): 48 VDC, 100 mA max. (residual voltage: 2 V max.)
Light-ON/Dark-ON selectable
Control output
Life
expectancy
(relay output)
White paper (200 × 200 mm):
700 mm
Mechanical
50,000,000 times min. (switching frequency: 18,000 times/h)
Electrical
100,000 times min. (switching frequency: 1,800 times/h)
Relay output
(E3JM-@@M4 (T) models) Operate or reset: 30 ms max.
DC SSR output (E3JM-@@S4 (T) models) Operate or reset: 5 ms max.
Sensitivity adjustment
---
One-turn adjuster
Timer function *
ON-delay/OFF-delay/One-shot delay switch selectable
Delay time: 0.1 to 5 s (adjustable), only for E3JM-@@@4T
Ambient illumination
(Receiver side)
Incandescent lamp: 3,000 lx max.
Ambient temperature range
Operating: −25°C to 55°C, Storage: −30°C to 70°C (with no icing or condensation)
Ambient humidity range
Operating: 45% to 85% (with no condensation), Storage: 35% to 95% (with no condensation)
Insulation resistance
20 MΩ min. at 500 VDC
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min.
Vibration
resistance
Destruction
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Malfunction
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock
resistance
Destruction
500 m/s2 3 times each in X, Y, and Z directions
Malfunction
100 m/s2 3 times each in X, Y, and Z directions
Degree of protection
IEC 60529: IP66
Connection method
Terminal block
Weight (packed state)
Approx. 270 g
Material
Accessories
Approx. 160 g
Case
ABS (Acrylonitril Butadiene Styrene)
Lens
Methacrylic resin
Cover
Polycarbonate
Mounting
Bracket
Iron
Mounting Bracket (with screw), Nuts, Terminal Protection Cover, One set of cable connection nuts (excluding -US Models), Instruction manual, Reflector (E39-R1: only for Retro-reflective Sensors)
*The timer cannot be disabled for models with timer functions (E3JM-@@@4T).
3
E3JM
Engineering Data (Reference Value)
Parallel Operating Range
E3JM-10@4(T)-N
E3JM-10@4(T)-N + E39-S39 (Optional Slit) E3JM-R4@4(T) + E39-R1
(A Slit is mounted to the Emitter and Receiver.) (Supplied Reflector)
Distance Y (mm)
Through-beam
600
400
200
0
2
4
6
8
10
12
Retro-reflective
60
Distance Y (mm)
Distance Y (mm)
Through-beam
Y
40
X
20
0
14 16
0.5
1
1.5
2
2.5
3
150
Reflector: E39-R1
100
50
0
3.5
1
2
3
4
5
6
−200
Distance
X (m)
−20
−400
Y
−50
−40
−100
−60
−150
8
Y
X
−600
7
Distance
X (m)
Distance X (m)
X
Operating Range
Diffuse-reflective
E3JM-DS70@4(T)
Distance Y (mm)
60
Sensing object: 200 × 200 mm
50
Y
40
X
30
20
10
0
2
4
6
8
10
−10
Distance
X (m)
−20
White paper
Black carbon
SUS (Luster)
Aluminum foil
(No luster on
the back)
−30
−40
−50
−60
Excess Gain Ratio vs. Set Distance
Retro-reflective
E3JM-10@4(T)-N
E3JM-R4@4(T) + E39-R1
(Supplied Reflector)
1,000
E3JM-R4@4(T) + E39-R3
(Optional Reflector)
1,000
Reflector: E39-R3
500
300
Excess gain ratio
1,000
Reflector: E39-R1
500
500
100
50
Excess gain ratio
Excess gain ratio
Through-beam
100
50
100
50
30
10
10
10
5
5
5
3
Operating
1
level
0.5
Operating 1
level
0.5
Operating 1
level
0.5
0.3
0.1
0
2
4
6
8
10
12
14
16 18
Distance (m)
0.1
0.1
0
1
2
3
4
5
6
7
8
9
Distance (m)
0
1
2
3
4
5
6
7
8
9
Distance (m)
4
E3JM
Sensing Object Size vs. Sensing Distance
Diffuse-reflective
E3JM-DS70@4(T)
1,000
Sensing object:
500 white paper 200 × 200 mm
Distance (m)
Excess gain ratio
E3JM-DS70@4(T)
100
12
10
50
8
10
6
White paper
Black carbon
SUS (Luster)
Aluminum foil
(No luster on
the back)
5
4
Operating
1
level
0.5
2
0.1
0
100
200
300
400
500
600
700
800 900
Distance (mm)
0
20
40
60
80
100 120 140 160 180 200 220
Side length of sensing object (mm)
5
E3JM
I/O Circuit Diagrams
Relay Output Models
Model
E3JM-10M4(T)-N *1
E3JM-R4M4(T)
Timing chart
24 to 240 VAC
12 to 240 VDC
Incident light
No incident light
Indicator
(red) *2
L-ON (Ta)
E3JM-DS70M4(T)
Output circuit
D-ON (Ta)
Photoelectric
Sensor main
circuit
ON
OFF
ON
OFF
ON
OFF
Power
Source
1
No polarity
2
3
Tb
4
Tc
5
Ta
Contact output
(Built-in Relay: G6C)
Refer to page 7 for information on Sensors with timers (T).
DC SSR Output Models
Model
Timing chart
Output circuit
24 to 240 VAC
12 to 240 VDC
Power
Source
1
No polarity
E3JM-10S4(T)-N *1
Incident light
No incident light
Indicator
(red) *2
E3JM-R4S4(T)
L-ON (Ta)
E3JM-DS70S4(T)
D-ON (Ta)
2
ON
OFF
L/ON
OFF
Refer to page 7 for information on Sensors with timers (T).
NO
I1
D/ON
Photoelectric
Sensor
main
circuit
Load
3
Drive
Circuit
ON
OFF
ON
Load
5
Drive
Circuit
NC
48 VDC
max.
I2
I1+I2<100 mA
4
COM
Note: Connect terminal 1 to any polarity and terminal 2 to the power supply because there is no polarity on the Emitter side.
*1. Models numbers for Through-beam Sensors (E3JM-10@4(T)-N) are for sets that include both the Emitter and Receiver.
The model number of the Emitter is always E3JM-10L-N. Add a “D” to get the model number of the Receiver (example: E3JM-10DM4-N). Confirm the model numbers
of the Emitter and Receiver in Ordering Information.
*2. This is the light indicator on Sensors without a timer and the operation indicator on Sensors with a timer.
6
E3JM
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
● Designing
Operation
Note:
Switch
configuration
Switch selection
MODE
0
1
MODE
0
1
Models
without
timer
D·ON
D·ON
L·ON
ON-delay
MODE
0
1
Models
with
timer
L·ON
D·ON
TIMER
SW2
Operation
Selector
Selector switch for
timer mode
Light-ON, Relay ON,
DC output switching
element ON
D·ON
SW1
TIMER
SW2
Both SW1 and
SW2 at "0."
L·ON
ON
OFF
D·ON
ON
OFF
One-shot delay
MODE
0
1
L·ON
No incident light
Dark-ON, Relay ON
DC output switching
element ON
OFF-delay
MODE
0
1
SW1
Timing charts
Incident light
L·ON
MODE
0
1
D·ON
L·ON
Operation
selector
D·ON
The white part of the DIP switch indicates which setting is selected.
ON-delay
OFF-delay
One-shot delay
MODE
0
1
L·ON
D·ON
SW1
TIMER
SW2
Only SW2 at "1."
L·ON
SW1
TIMER
SW2
Only SW1 at "1,"
which overrides either
setting of SW2.
Incident light
Incident light
No incident light
No incident light
Incident light
No incident light
T
T
ON
L·ON
OFF
T
ON
D·ON
OFF
ON
L·ON
OFF
T
ON
D·ON
OFF
T
ON
L·ON
OFF
T
ON
D·ON
OFF
Note: The operation selector is the same as that for models
without a timer.
Output Relay Contact
If E3JM is connected to a load with contacts that spark when the load is turned OFF (e.g., a contactor or valve), the normally-closed side may be
turned ON before the normally-open side is turned OFF or vice-versa. If both normally-open output and normally-closed output are used
simultaneously, apply an surge suppressor to the load.
Refer to OMRON’s PCB Relays Catalog (X33) for typical examples of surge suppressors.
7
E3JM
● Wiring
Connecting and Wiring
● Others
Terminal Protection Cover (Provided)
• We recommend connecting a cable with a conductor cross-section
of 0.3 mm2 and an outer diameter of 6 to 8 mm.
• Be sure to firmly tighten the cover in order to maintain waterproof
and dustproof properties. The screw size of the conduit sockets is
shown in the following table.
Model
E3JM-@
Conduit socket thread size
PF1/2
The terminal protection cover is designed to improve safety by
maintaining the sensitivity properties of the product and by preventing
any contact with charged sections while it is being operated with the
mode set to the timer mode. Mount the product as shown in the
following diagram (mount the Through-beam Model on the Receiver
side).
• When using the DC SSR output model, the total of the load current
for the Light-ON output (NO) and that for the Dark-ON (NC) should
be 100 mA max. If the total exceeds 100 mA, the load short-circuit
protection function will be activated (this function will be reset when
the power of the Photoelectric Sensor is turned OFF).
Terminal protection cover
E3JM
Cable End Treatment
Adjust the four wires to the same length when
the Ta output is to be used only. If both the Ta
and Tb outputs are to be used, treat them as
shown in the following diagram.
Recommended example
Approx.
45 mm
Ambient Conditions (Installation Area)
Power
source
Tc, Ta
The E3JM will malfunction if installed in the following places.
• Places where the E3JM is exposed to a dusty environment.
• Places where corrosive gases are produced.
Tb
Rubber bushing (provided)*
Washer (provided)*
Tightening nut (provided)*
Approx.
55 mm
Round type
10 max.
10 max.
7 max.
3.6 dia. min.
(Unit: mm)
Fork type
Receiver
Recommended Crimp Terminal Dimensions
Emitter
* These parts are not provided with models with a -US suffix.
7 max.
19 max.
(After crimping)
7 max.
3.6 dia. min.
7 max.
19 max.
• Places where the E3JM is directly exposed to water, oil, or
chemicals.
(After crimping)
Receiver
Emitter
Note: Use terminals with insulation tube (recommended crimp terminal: 1.25 to
3.5).
8
E3JM
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this datasheet unless otherwise specified.
Sensors
E3JM-10@4(T)-N *
E3JM-R4@4(T)
E3JM-DS70@4(T)
With Mounting Bracket Attached
With Mounting Bracket Attached
8
8
24.5
22
6
24.5
6 dia.
12.4
18
39.5
Emitter: E3JM-10L-N
Receiver: E3JM-10D@4 (T) -N
25
11.5
4.1
Lens: 14.8 dia.
44
(A) *2
Mounting Holes
Two, M6
42
6 dia.
12.4
75
65
Indicator *1
25
18
39.5
11.5
4.1
6
75
65
Indicator *1
3
3
Emitter
65
80
9
1.6
15
6 (12.4)
6.4
6
Optical axis
Two, M4×30
65
80
22
6 (12.4)
6.4
6
JIS
B 0202
PF1/2
20
Steel 5
40
54.5
Hexagonal nut
(Diagonal: 22)
Applicable cable:
6 to 8 dia.
*1. Emitter: Power indicator
Receiver: Light indicator (without timer function)
Operation indicator (with timer function)
*2. Mounting Brackets can be used on the A side.
Note: The operating mode switch and timer
mode switch are located inside the cover.
Receiver
Two, M4 × 30
47.5
9
1.6
15
(A) *2
Mounting Holes
JIS
B 0202
PF1/2
20
Steel
5
40
54.5
Hexagonal nut
(Diagonal: 22)
Applicable cable:
6 to 8 dia.
Two, M6
*1. Light indicator (without timer function)
Operation indicator (with timer function)
*2. Mounting Brackets can be used on the A side.
42
Note: The operating mode switch, timer mode switch, and
sensitivity adjuster (sensitivity adjuster: E3JMDS70@4(T) only) are located inside the cover.
* Models numbers for Through-beam Sensors (E3JM-10@4(T)-N) are for sets that include both the Emitter and Receiver.
The model number of the Emitter is always E3JM-10L-N. Add a “D” to get the model number of the Receiver (example: EE3JM-10DM4-N). Confirm the model
numbers of the Emitter and Receiver in Ordering Information.
Accessories (Order separately)
Seal-type Long Slit
E39-S39
Mounting Brackets
Refer to E39-L/E39-S/E39-R for details.
14
1±0.1
Materials: Polyester
0.1-mm thick
20 26.5
9
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2015.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2015 All Right Reserved.