SITRANS F US Sono 3100 - SITRANS FUS060 Catalog Sheet

© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONO 3100/FUS060
■ Overview
■ Design
The SONO 3100 in combination with FUS060 consists of a
SONO 3100 sensor, SONO 3200 transducers with O-rings or
flanges depending on selection - and a FUS060 transmitter.
SONO 3100 is basically supplied in a 2-path solution with
flanges in sizes from DN 100 to DN 600 and without flanges in
sizes from DN 100 to DN 300.
1-path or 4-path special versions are available on request, depending on size (DN 25 to DN 1200).
SONO 3100 is as standard available in carbon steel from DN 100
to DN 600.
FUS060 is designed for remote wall mounting only.
3
■ Technical specifications
The transmitter related to this system is the SITRANS FUS060.
Technical specifications to the FUS060 see page 3/247.
2-path sensor fitted with four SONO 3200 transducers
Error in measurement
The combination of the SONO 3100 sensor and the FUS060
transmitter is ideal for applications where process shut-down is
impossible during service and where there is a need for extreme
high/low temperatures and pressures.
Transducers can be changed without interrupting operation.
SONO 3100 can optionally be delivered as a 4-path solution for
absolute best performance and accuracy.
■ Benefits
• Transducers can be replaced under pressure
• Measurement of all liquids less than 350 Cst, conductive or
non-conductive
• No pressure drop
• Reliable and accurate flow measurements
• Long-time stability
• On request as special versions:
- Special sensor material, e.g. Duplex, stainless steel
- High/low temperature sensor version: +250 °C (+482 °F)/
-200 °C (-328 °F) sensors
- Pressure rating 430 bar (6235 psi)
- Special sensor sizes down to DN 25
- 1-path or 4-path sensor technology
Error in measurement at reference
conditions
v > 0.5 ... 10 m/s, <  0.5 % of rate
(v=flow velocity)
Max flow velocity
10 m/s (32 ft/s)
Nominal size
DN 100 ... 600 (4" ... 24")
Media temperature
• Standard
-10 ... +200 °C (14 ... 392 °F)
• ATEX Ex d version
-20 ... +200 °C (-4 … +392 °F)
• ATEX Ex i version
-10 ... +200 °C (14 ... +392 °F)
• Specials
-200 °C (-328 °F) or
up to 250 °C (482 °F)
Ambient temperature
• Standard and Ex-i version
-20 ... +180 °C (-4 ... +356 °F)
Enclosure
IP67 (NEMA 4X/6)/IP68 (NEMA 6P)
and ATEX (see below)
Process connections
PN designated, EN 1092-1,
type 11 (B)
Pipe material carbon steel
■ Application
The main application for SONO 3100 in combination with transmitter type FUS060 is to measure volume flow within:
• Petrochemical industry
• Power engineering
• Water and waste water
• Oil and liquefied gases
SITRANS FUS060 holds ATEX for hazardous areas, HART and
PROFIBUS PA. SONO 3100 holds ATEX Ex approval.
Class designated, EN 1759-1
Pipe material carbon steel
Siemens FI 01 · 2016
• DN 200 ... 600 (8" ... 24"), PN 10
• DN 100 ... 600 (4" ... 24"), PN 16
• DN 200 ... 600 (8" ... 24"), PN 25
• DN 100 ... 500 (4" ... 20"), PN 40
• DN 100 … 600 (4" … 24")
Class 150
• DN 100 … 300 (4" … 12")
Class 300
Without flanges (EN 10217),
(weld-in version)
only in carbon steel
• DN 350 … 600 (14" … 24"), PN 10
• DN 100 … 600 (4" … 24"), PN 16
• DN 200 … 600 (8" … 24"), PN 25
• DN 100 … 500 (4" … 20"), PN 40
Transducer SONO 3200
O-ring or flange versions
Materials
Pipe
Flange
PN
Class
Transducer body
Transducer terminal house
3/266
-20 ... +60 °C (-4 ... +140 °F)
• Ex d version
Steel EN 1.0345-P235GH
EN 10025-S235JRG2, 1E1
ASTM A105,1,1
Stainless steel AISI 316 or similar
Stainless steel AISI 316 or plastic
PA 6.6
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONO 3100/FUS060
Certificates and approvals
System ATEX approval for
SONO 3100 together with transmitter FUS060-Ex
ATEX II 2G Ex dem [ia/ib] IIC
T6/T4/T3 Gb or
ATEX II 2G Ex d IIC T3-T6 Gb with
SONO 3200 Exd transducers (for
standard FUS060 transmitter,
installed outside of Ex zone)
For FUS060 Ex version the transducer cable length is restricted to
3 m (9.84 ft), in order to meet
requirements for electrical immunity.
Conformity certificate
The devices are supplied as standard with a Siemens Certificate of
Conformity on CD
Material certificate
Material certificate according to
EN 10204-3.1 is optionally available
NDT examination report
Extended material certificate is
optionally available
Pressure certificate
Pressure test according
EN 1024-2.3 optionally available
Calibration report
A standard calibration report is
shipped with each flowmeter.
Optionally available:
Extended accredited ISO/IEC
17025 calibration certificates
Approvals
No custody transfer approvals
The sensor SONO 3100 with transmitter FUS060 conforms to Product
Family Standard EN 61326/A3 appendix A (Title: Electrical Equipment
for Measurement control and laboratory use – EMC requirements).
The sensors are approved according to EU directive 2014/68/EU dated
27 June 2014 regarding fluid group 1, classified in category III. Design
according to EN 13480 (PED Directive).
The SONO 3100 as weld-in version does not include the flanges. Thus, it
can neither be tested nor approved according to PED. After the installation, all installation-related activities (welding, pressure test etc.) are the
responsibility of the customer.
Selection and Ordering data
Article No. Order code
SITRANS F US SONO 3100 sensor
2-path
7 ME 3 1 0 0 7 77 7 7 - 7 7 7 7 7 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Diameter
Qn setting [m3/h]
DN 100 (4")
DN 100 (4")
DN 100 (4")
28
100
220
1N
1P
1R
DN 125 (5")
DN 125 (5")
DN 125 (5")
44
150
350
1S
1T
1V
DN 150 (6")
DN 150 (6")
DN 150 (6")
64
220
500
2A
2B
2D
DN 200 (8")
DN 200 (8")
DN 200 (8")
110
380
900
2E
2F
2H
DN 250 (10")
DN 250 (10")
DN 250 (10")
180
600
1300
2J
2K
2M
DN 300 (12")
DN 300 (12")
DN 300 (12")
250
850
2000
2N
2P
2R
DN 350 (14")
DN 350 (14")
DN 350 (14")
350
1000
28001)
2S
2T
2V
DN 400 (16")
DN 400 (16")
DN 400 (16")
450
1300
3600
3A
3B
3D
DN 500 (20")
DN 500 (20")
DN 500 (20")
1300
2200
42001)
3J
3K
3M
DN 600 (24")
DN 600 (24")
DN 600 (24")
1300
3200
42001)
3S
3T
3V
3
Flange norm and pressure rating
(All sizes are not available in all pressure ratings)
EN 1092-1
PN 10 (DN 200 ... DN 600)
PN 16 (DN 100 ... DN 600)
PN 25 (DN 200 ... DN 600)
PN 40 (DN 100 ... DN 500)
B
C
D
E
ANSI B16.5
class 150 (DN 100 ... DN 600)
class 300 (DN 100 ... DN 300)
H
J
Pipe without flanges (EN 10217) (weld-in
version)2)
PN 10 (DN 200 ... DN 600)
PN 16 (DN 100 ... DN 600)
PN 25 (DN 200 ... DN 600)
PN 40 (DN 100 ... DN 500)
P
Q
R
S
Siemens FI 01 · 2016
3/267
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONO 3100/FUS060
Selection and Ordering data
Article No. Order code
Selection and Ordering data
SITRANS F US SONO 3100 sensor
2-path
7 ME 3 1 0 0 -
Additional information
7 77 7 7 - 7 7 7 7 7 7 7
Please add „-Z" to Article No. and specify Order
code(s) and plain text.
Pipe and flange material
Carbon steel (DN 100 ... 1200)
Calibration
1
Transducer type and approval
3
IP67 (NEMA 4X/6) PA housing, PN 40,
O-ring, 50 mm, 100 °C (212 °F)
(DN 100 ... 600)
IP68 SS housing, PN 40, O-ring, 50 mm,
200 °C (392 °F) (DN 100 ... 600)
IP68 SS housing, PN 40, O-ring, 50 mm,
180 °C (356 °F), Ex d ATEX approval (only
with standard FUS060) (DN 100 ... 600)
1
IP67 (NEMA 4X/6) PA housing, PN 40,
flange, 88 mm, 100 °C (212 °F)
(DN 100 ... 300)
IP68 SS housing, PN 40, flange, 88 mm,
200 °C (392 °F) (DN 100 ... 300)
IP68 SS housing, PN 40, flange, 88 mm,
180 °C (356 °F), Ex d ATEX approval (only
with standard FUS060) (DN 100 ... 300)
4
IP67 SS housing, PN 40, O-ring, 50 mm,
190 °C (374 °F), Ex i ATEX approval (only
with FUS060 Ex-version) (DN 100 ... 600)
IP67 SS housing, PN 40, flange, 88 mm,
190 °C (374 °F), Ex i ATEX approval (only
with FUS060 Ex-version) (DN 100 ... 300)
7
Cable gland entries
Cable glands M20 in transducers and in
transmitter M25/20/16 x 1.5
Cable glands ½" NPT in transducers and in
transmitter
2
3
5
8
2
D
0
1
2
3
4 x 60 m, max. 70 °C (158 °F)
4 x 90 m, max. 70 °C (158 °F)
4 x 120 m, max. 70 °C (158 °F)
4
5
6
4 x 3 m, high temp. max. 200 °C (392 °F),
the only option for Ex i
4 x 15 m, high temp. max. 200 °C (392 °F)
7
8
Reduced Q value during calibration (Qn setting unchanged).
For weld-in sensor versions according to EN 10217 (flangeless sensors
7ME3100-xxYxx-xxxx, Y = P, Q, R, S) the tube roundness shall be agreed
by ordering (only if the factor of Du / Wxx > 100).
3/268
Siemens FI 01 · 2016
D20
Accredited Siemens ISO/IEC 17025 calibration for
DN 200 to DN 600 with Qn as selected in diameter.
Calibration certificate: 2 x 5 points in 5 %, 10 %,
25 %, 50 % and 100 % Qn (max. flow 2800 m3/h).
D21
Accredited Siemens ISO/IEC 17025 calibration for
DN 400 to DN 600 with Qn as selected in diameter.
Calibration certificate: 2 x 5 points in 5 %, 10 %,
25 %, 50 % and 100 % Qn (max. flow 8000 m3/h).
D22
F10
F11
F12
F21
Y17
Please use online Product selector to get latest
updates. Product selector link:
www.pia-portal.automation.siemens.com
N
P
Q
PROFIBUS PA, 1 pulse/frequency
2)
Accredited Siemens ISO/IEC 17025 calibration for
DN 100 to DN 200 with Qn as selected in diameter.
Calibration certificate: 2 x 5 points in 5 %, 10 %,
25 %, 50 % and 100 % Qn (max. flow 630 m3/h).
Stainless steel TAG plate (1 x 24 x 80 mm),
wire fixed. Font size depends on text length:
8 mm for 1 ... 10 characters, 4 mm for
11 ... 20 characters (specify in plain text).
1
B
C
1)
Included
Tag name plate
FUS060 output module
HART, 1 pulse output, 1 relay
HART Ex, 1 pulse output, 1 relay
Transducer coaxial cable
4 x 3 m, max. 70 °C (158 °F),
the only option for Ex i
4 x 15 m, max. 70 °C (158 °F)
4 x 30 m, high temp. max. 200 °C (392 °F)
4 x 30 m, max. 70 °C (158 °F)
Production calibration DN 100 ... DN 600
(with certificate)
Material certificate
EN 10204-3.1
EN 10204-3.1 and 100 % NDT on weldings,
DN 100 ... DN 400
EN 10204-3.1 and 100 % NDT on weldings,
DN 500 ... DN 600
Pressure certificate
EN 10204-2.3
6
Transmitter version of SITRANS FUS060
IP65 (NEMA 4), 120/230 V AC
IP65 (NEMA 4), 24 V AC/DC
IP65 (NEMA 4), 24 V AC/DC ATEX Ex version
Order code
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONO 3100/FUS060
■ Flowmeter SONO 3100 with FUS060 operating instructions, accessories and spare parts
Operating instructions
Description
Article No.
SITRANS FUS060
• English
• German
A5E01204521
A5E02123845
SITRANS F US SONO 3100
• English
A5E00814513
This device is shipped with a Quick Start guide and a CD containing further SITRANS F US literature.
All literature is available to download for free, in a range of languages, at
www.siemens.com/processinstrumentation/documentation
Accessories
Description
Article No.
Potting kit for terminal box of
SONO 3200 transducer for
IP68/NEMA 6P
(not for Ex sensors)
FDK:085L2403
Description
Transducer
length
Article No.
Extraction tool for
replacement of
SONO 3200 O-ring
transducers
under pressure and
for hot-tapping (working conditions:
typically water,
max. 40 bar and max.
60 °C (max. 580 psi
and max. 140 °F))
50 mm
(1.97")
transducers
FDK:085B5331
3
Cable connection boxes
(For the connection of individually transducer cables with the
FUS060 transducer cables)
Article No.
Description
Junction box for coaxial cable
• IP65 metal box for 4 coaxial
cables
FDK:085B1361
• IP65 EEx e plastic box for 4
coaxial cables, no ATEX approval
FDK:085B1363
Spare parts
Transducer SONO 3200 spare parts, complete units
Type
Material Gasket
Press.
rating
Terminal housing
Approv. Temp. range [°C (°F)]
Length
mm (inch)
Article No.
O-ring 316 SS
O-ring
PN 40
Plastic, PA 6.6 M20
-20 ... +100 (-4 ... +212)
50 (1.97)
FDK:085B5453
O-ring 316 SS
O-ring
PN 40
316 SS M20
-20 ... +200 (-4 ... +392)
50 (1.97)
FDK:085B5450
O-ring 316 SS
O-ring
PN 40
316 SS M20
Ex d1)
-20 ... +200 (-4 ... +392)
50 (1.97)
FDK:085B5451
O-ring 316 SS
O-ring
PN 40
316 SS M20
Ex i2)
-10 ... +200 (14 ... 392)
50 (1.97)
A5E00836448
O-ring 316 SS
O-ring
PN 40
Plastic, PA 6.6 ½" NPT
-20 ... +100 (-4 ... +212)
50 (1.97)
A5E00839472
O-ring 316 SS
O-ring
PN 40
316 SS ½" NPT
-20 ... +200 (-4 ... +392)
50 (1.97)
A5E00839431
Flange 316 SS
Graphite
PN 40
Plastic, PA 6.6 M20
-20 ... +100 (-4 ... +212)
88 (3.47)
FDK:085B5461
Flange 316 SS
Graphite
PN 40
316 SS M20
-20 ... +200 (-4 ... +392)
88 (3.47)
FDK:085B5462
Flange 316 SS
Graphite
PN 40
316 SS M20
-20 ... +200 (-4 ... +392)
88 (3.47)
FDK:085B5463
Ex d1)
Flange 316 SS
Graphite
PN 40
316 SS M20
-10 ... +200 (14 ... +392)
88 (3.47)
A5E00836465
Flange 316 SS
Graphite
PN 40
Plastic, PA 6.6 ½" NPT
-20 ... +100 (-4 ... +212)
88 (3.47)
A5E00839479
Flange 316 SS
Graphite
PN 40
316 SS ½" NPT
-20 ... +200 (-4 ... +392)
88 (3.47)
A5E00839440
Flange 316 SS
Copper
ring
PN 40
316 SS PG13.5
(cryogenic version)
-200 ... +100 (-328 ... +212) 88 (3.47)
FDK:085B5416
Flat
316 SS
flange
Flat
gasket
PN 40
316 SS M20
(cryogenic version)
-200 ... +100 (-328 ... +212) 88 (3.47)
A5E02593524
-20 ... +180 (-4 ... +356)
88 (3.47)
FDK:085B5464
-20 ... +200 (-4 ... +392)
88 (3.47)
FDK:085B5465
Flange 316 SS
Graphite
PN 160
316 SS M20
Flange 316 SS
Graphite
PN 160
316 SS M20
Ex i
2)
Ex d1)
1)
ATEX (Ex) IIC 2G Ex d IIC T3-T6 Gb
2)
For systems with FUS060 ATEX IIC 2G Ex dem [ia/ib] T6/T4/T3
Siemens FI 01 · 2016
3/269
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONO 3100/FUS060
Terminal housing for SONO 3200 sensor
3
Type
Pressure rating Material
Temp. range [°C (°F)]
Article No.
Terminal housing (M20 cable gland)
N/A
PA 6.6
-20 ... +100 (-4 ... +212)
FDK:085B5501
Terminal housing (M20 cable gland)
N/A
ASTM 316
-20 ... +200 (-4 ... +392)
FDK:085B5504
Terminal housing (½" NPT cable gland)
N/A
PA 6.6
-20 ... +100 (-4 ... +212)
A5E00839460
Terminal housing (½" NPT cable gland)
N/A
ASTM 316
-20 ... +200 (-4 ... +392)
A5E00839427
Ex d1) terminal housing (M20 cable gland)
N/A
ASTM 316
-20 ... +200 (-4 ... +392)
FDK:085B5505
Ex i2) terminal housing (M20 cable gland)
N/A
ASTM 316
-10 ... +200 (14 ... 392)
A5E00835255
1)
ATEX (Ex) IIC 2G EEx d IIC T3 ... T6
2)
For systems with FUS060 ATEX IIC 2G Ex dem [ia/ib] T6/T4/T3
SONO 3200 spare parts, transducer body without terminal housing, including insert
Type
Material
Gasket
Pressure rating
Temp. range [°C (°F)]
Length
Article No.
mm (inch)
O-ring
316 SS
O-ring
PN 40
-20 ... +200 (-4 ... +392)
50 (1.97)
FDK:085B1405
Flange
316 SS
Graphite
PN 40
-20 ... +200 (-4 ... +392)
88 (3.47)
FDK:085B1464
Type
Temp. range [°C (°F)]
Length
Article No.
mm (inch)
Insert
-20 ... +200 (-4 ... +392)
50 (1.97)
FDK:085B1411
Insert
-20 ... +200 (-4 ... +392)
88 (3.47)
FDK:085B1459
SONO 3200 spare parts, transducer insert
Transducer SONO 3200 gaskets
Type
Pressure rating
Material
Temperature range
[°C (°F)]
Article No.
Gasket O-ring (3 pcs. for o-ring transducers)
PN 40
FKM
-20 … +200 (-4 ... +392)
FDK:085B1089
Gasket flange
PN 40/160
Graphite
-20 … +200 (-4 ... +392)
FDK:085B1080
Gasket and 12 mm (0.47") bolts and nuts PN 40
for flange transducers (4 pcs.)
AISI 316 or equal -20 … +200 (-4 ... +392)
FDK:085B1083
Gasket and 16 mm (0.63") bolts and nuts PN 160
for flange transducers (4 pcs.)
Graphite, 316 SS -20 … +200 (-4 ... +392)
FDK:085B1084
Gasket for cryogenics transducer with
flat flange (2 pcs.)
Graphite/metal
composite
3/270
Siemens FI 01 · 2016
PN 40
-200 … +100 (-328 ... +212) A5E02593522
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONO 3100/FUS060
SONO 3200 cable glands
Type/description
Temperature range
[°C (°F)]
black PA
plastic,
cable
-20 ... 100
(-4 ... +212)
Cables for SONO 3100 with FUS060
Appr. Article No.
A5E02246304
Ø 5 ... 13 mm
(1 pc.)
Description
Length
m (ft)
Article No.
Coaxial cable for
FUS060, (75 , max.
70 ºC (158 ºF), black
PVC)
(2 pcs.)
3 (9.84)
A5E00875101
15 (49.21)
A5E00861432
30 (98.43)
A5E01278662
60 (196.85) A5E01278682
90 (295.28) A5E01278687
½" NPT
-20 ... 100
gray PA
(-4 ... +212)
plastic,
cable
Ø 5 ... 9 mm
(1 pc.)
A5E02246309
½" NPT
-40 ... 100
crome(-40 ... +212)
plated
brass,
cable
Ø 5 ... 9 mm
(1 pc.)
A5E02246258
M20 stain- -25 ... 200
Ex i
less steel,
(-13 ... +392)
cable
Ø 4 ... 6 mm
(1 pc.)
A5E02246194
M20 Stain- -60 ... 180
Ex d
less steel,
(-76 ... +356)
cable
Ø 5 ... 8 mm
(1 pc.)
A5E02246311
120 (393.7) A5E01278698
High temp. coaxial 3 (9.84)
cable for FUS060;
15 (49.21)
with 0.3 m brown
PTFE high temp.
30 (98.43)
transducer part,
max. 200 °C
(392 °F) and black
PVC for remaining
transmitter part
with SMB plug, max.
70 ºC (158 ºF);
(impedance 75 )
(2 pcs.)
A5E00875105
SITRANS F US
special coaxial
cable sets for low
temperature cryogenic systems, with
SMB-plug for transmitter SITRANS
FUS060,
PTFE material, temp.
-200 ... +200 °C
(-328 ... .+392 °F),
impedance 75 
(2 pcs.)
10 (32.84)
A5E02085593
15 (49.21)
A5E03262088
30 (98.43)
A5E02085644
3
A5E00861435
A5E01196952
40 (131.23) A5E02085649
■ Schematics
1
Xi
4
Path 1
Sensor
1
4 1A
1A
2B
1B
2A
1
2B
4
Path 2
1A
1B
2A
2B
Sensor
1
2A
4
Electrical connection of SITRANS FUS060 and SONO 3100
Siemens FI 01 · 2016
3/271
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONO 3100/FUS060
■ Dimensional drawings of sensor SONO 3100
H
B
D10 ... D300
Du
L10 ... L300
L
3
θ
A**
Sensor SONO 3100 with EN norm
PN 10
DN
PN 16
PN 25
PN 40
DU
L1) 4)
B 5)

H
W102) D10
L101)
W162) D16
L161)
W252)
D25
L251)
W402)
D40
L401)
[mm]
[mm]
[mm]
[mm]
[°]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
[mm]
100
114.3
860
305
453) 42.8
-
-
-
3.6
220
960
-
-
-
3.6
235
990
125
139.7
862
325
453) 64.5
-
-
-
4.0
250
970
-
-
-
4.0
270
990
150
168.3
862
350
453) 78.1
-
-
-
4.5
285
970
-
-
-
4.5
300
1010
200
219.1
668
430
453) 102.1
6.3
340
790
6.3
340
790
6.3
360
820
6.3
375
840
250
273.0
714
480
453) 127.6
6.3
395
850
6.3
405
850
7.1
425
890
7.1
450
920
300
323.9
607
525
453) 151.8
7.1
445
740
7.1
460
760
8.0
485
790
8.0
515
830
350
355.6
639
550
453) 166.4
8.0
505
770
8.0
520
800
8.0
555
840
8.8
580
880
400
406.4
703
600
453) 191.3
8.0
565
850
8.0
580
875
8.8
620
925
11.1
660
975
500
508.0
797
690
453) 241.1
7.1
670
950
8.0
715
980
10.0
730
1050
14.2
755
1080
600
610.0
912
705
60
7.1
780
1075
8.8
840
1105
11.0
845
1165
-
-
-
294.8
1)
Length tolerance (mm): DN 100 +2/-3, DN 125 ... 200 +3/-4, DN 250 ... 400
+4/-5, DN 500 ...600 +5/-6
2)
Wall thickness for pressure rates PN 6 ... 40. For weld-in sensor versions
according EN10217 (flangeless sensors 7ME3100-xxYxx-xxxx, Y=P, Q, R, S )
the tube roundness shall be agreed by ordering (only if the factor of
Du/Wxx > 100).
3)
For all sensors with flange transducers path angle are 60º
4)
L is the length of sensor versions without flanges (weld-in version)
For weld-in sensor versions according to EN 10217 (flangeless sensors
7ME3100-xxYxx-xxxx, Y = P, Q, R, S) the tube roundness shall be agreed
by ordering (only if the factor of Du/Wxx > 100).
5)
B dimension value is an approximate information and may differ a little by
flange pressure rate.
A**) Space required for replacement of transducer min. 230 mm (9.1 inch).
For replacement with special tool (extraction tool) see more information
on page 3/269.
SONO 3100, 2-path
Nominal diam.
Flange type - Weight [kg (lb)]
DN
PN 10
PN 16
PN 25
PN 40
100 (4")
-
32 (70.5)
-
35 (77.2)
125 (5")
-
38 (83.8)
-
44 (97.0)
150 (6")
-
45 (99.2)
-
52 (114.6)
200 (8")
59 (130.0)
58 (127.9)
70 (154.3)
79 (174.2)
250 (10")
73 (161.0)
75 (163.3)
96 (211.6)
117 (257.9)
300 (12")
83 (183.0)
92 (202.8)
114 (251.3)
151 (332.9)
350 (14")
98 (216.0)
113 (249.1)
145 (332.9)
191 (421.1)
400 (16")
119 (262.4)
141 (310.9)
191 (421.1)
275 (606.3)
500 (20")
153 (337.3)
207 (456.4)
284 (626.0)
379 (836.0)
600 (24")
193 (425.5)
276 (608.5)
363 (800.3)
-
Weight of system incl. process flanges and standard O-ring transducers. For sensors with flange transducer please add approx. 10 kg (22.05 lb).
For SS terminal housings instead of the standard PA housing add approx. 5 kg (11.03 lb).
3/272
Siemens FI 01 · 2016
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONO 3100/FUS060
H
B
D10 ... D300
Du
L10 ... L300
L
θ
3
A**
Sensor SONO 3100 with ANSI norm
Class 150
Class 300
Size (DN) DU
L1) 4)
B 5)

H
W1502)
D150
L1501)
W3002)
D300
L3001)
inch (mm) [inch]
[inch]
[inch]
[°]
[inch]
[inch]
[inch]
[inch]
[inch]
[inch]
[inch]
4 (100)
33.86
12.01
453)
1.69
0.14
9.00
39.86
0.25
10.00
40.62
4.50
5 (125)
5.50
33.94
12.80
453)
2.54
0.15
10.00
40.94
0.27
11.00
41.70
6 (150)
6.63
33.94
13.78
453)
3.07
0.16
11.00
40.94
0.30
12.50
41.70
8 (200)
8.63
26.30
16.93
453)
4.02
0.16
13.50
34.30
0.29
15.00
35.06
10 (250)
10.75
28.11
18.90
453)
5.02
0.18
16.00
36.11
0.34
17.50
37.35
12 (300)
12.75
23.90
20.67
453)
5.98
0.20
19.00
32.90
0.39
20.50
34.14
14 (350)
14.00
25.16
21.65
453)
6.55
0.21
21.00
35.16
-
-
-
16 (400)
16.00
27.68
23.62
453)
7.53
0.22
23.50
33.74
-
-
-
9.49
0.26
27.50
42.76
-
-
-
11.61
0.30
32.00
47.91
-
-
-
20 (500)
20.00
31.38
27.17
453)
24 (600)
24.00
35.91
27.76
60
1)
Length tolerance (mm): 4" +0.08"/-0.12" (+2/-3mm), 5" ... 8" +0.12"/
-0.16" (+3/-4mm), 10" to 16" +0.16"/-0.20" (+4/-5mm), 20" ... 24" +0.20"/
-0.24" (+5/-6mm)
2)
Minimum wall thickness for pressure rates Class 150 or Class 300. For
weld-in sensor versions according to EN 10217 (flangeless sensors
7ME3100-xxYxx-xxxx, Y = P, Q, R, S) the tube roundness shall be agreed
by ordering (only if the factor of Du/Wxx > 100).
3)
For all sensors with flange transducers path angle are 60º
4)
L is the length of sensor versions without flanges (weld-in version)
For weld-in sensor versions according to EN 10217 (flangeless sensors
7ME3100-xxYxx-xxxx, Y = P, Q, R, S) the tube roundness shall be agreed
by ordering (only if the factor of Du/Wxx > 100).
5)
B dimension value is an approximate information and may differ a little by
flange pressure rate.
A**) Space required for replacement of transducer min. 230 mm (9.1 inch).
For replacement with special tool (extraction tool) see more information in
„Sensor SONO 3100 accessories and spare parts" on page 3/269.
Siemens FI 01 · 2016
3/273
© Siemens AG 2016
Flow Measurement
SITRANS F US Inline
Flowmeter SONO 3100/FUS060
Approximate weights for SONO 3100 sensor with ANSI B16.5 flanges
3
Nominal diameter
Weight [kg (lb)]1)
DN
DN
CL150
[inch]
[mm]
[kg]
[lb]
[kg]
[lb]
4
100
32
70.5
35
77.2
5
125
38
83.8
44
97.0
6
150
45
99.2
52
114.6
8
200
58
127.9
79
174.2
10
250
75
165.3
117
257.9
12
300
92
202.8
151
332.9
14
350
113
249.1
-
-
16
400
141
310.9
-
-
20
500
207
456.4
-
-
600
276
608.5
-
-
24
1)
CL300
Weight of system incl. process flanges and standard O-ring transducers. For sensors with flange transducer please add approx. 10 kg (22.05 lb). For SS
terminal housings instead of the standard PA housing add approx. 5 kg (11.03 lb).
3/274
Siemens FI 01 · 2016