AVX MAV0010TP

Miniature AC Varistor
__________________________________________________________________________________________
AVX introduces Miniature AC varistors for use in automotive applications.
MAV series devices are an ideal solution to transient suppression in LC
resonant circuits intended for signal & power transfer. The AVX part
provides low loss in the resonant circuit yet is able to clamp large amounts
of transients in a bidirectional manner.
The ability to handle large transients makes the MAV series useful in low
power AC circuit protection as well. Applications including: AC sampling
circuitry, transformer secondaries, and GFI modules.
MAV
002
Miniature AC
Varistor
0
Case
Size
001 = 0603
002 = 0405
D
Capacitance
0 = Low
P
Reel Size
D = 7″ reel (1k)
R = 7″ reel (4k)
T = 13″ reel (10k)
Termination
P = Plated Sn over
Ni Barrier
AVX Part
Number
VW(DC)
VW(AC)
VB
VC
IVC
IP
ET
IL
Cap
# of
Elements
MAV0010
70
50
120±15%
225
1
2
0.015
10
22pF
max
1
MAV0020
70
50
120±15%
225
1
3
0.02
10
8pF
max
2
VW(DC)
VW(AC)
VB
VC
IVC
DC Working Voltage [V]
AC Working Voltage [V]
Typical Breakdown Votage [V @ 1mADC]
Clamping Votage [V @ IVC]
Test Current for VC [A, 8x20µS]
IP
ET
IL
Cap
Peak Current [A, 8x20µS]
Transient Energy (J)
Maximum leakage current at the working voltage [µA]
Maximum capacitance @ 1MHz and 0.5VRMS
Dimensions
MAV0010
MAV0020
In mm
MAV0010
MAV0020
L
W
T
BW
BL
P
1.60 ± 0.15
1.00 ± 0.15
0.80 ± 0.15
1.37 ± 0.15
0.90 Max
0.66 Max
N/A
0.35 ± 0.15
0.20 ± 0.10
N/A
0.64 REF
0.36 ± 0.10
Voltage
V/I Curve
240
220
200
180
160
140
120
100
80
60
40
1E-09
1E-06
1E-03
1E+00
Leakage Current
MAV0010
MAV0020
1E+03
TRANSMISSION CHARACTERISTIC
0
Insertion Loss (dB)
-5
-10
-15
-20
-25
-30
1
10
100
Fre que ncy (M Hz)
MAV0010
1000
10000
MAV0020
IMPACT OF AC VOLTAGE ON LEAKAGE CURRENT
% Average Change in Leakage Current
0.2
0.15
0.1
0.05
0
‐0.05
‐0.1
‐0.15
‐0.2
‐0.25
‐0.3
‐60
‐40
‐20
0
20
40
60
80
100
Temperature (° C)
120 V Peak to Peak
165 Volts Peak to peak
120
140
IMPACT OF 110V PEAK TO PEAK SINE WAVE @ 125KhZ ON BREAKDOWN
VOLTAGE
Parellel 110 V PP @ 125 kHhz
+ Vb Change
- Vb Change
Breakdown Voltage
10.0%
7.5%
5.0%
2.5%
0.0%
-2.5%
-5.0%
-7.5%
-10.0%
Max
10 min
60 min
120 min
10 min
60 min
120 min
0.3%
0.6%
0.4%
0.3%
0.5%
0.3%
Min
0.2%
0.2%
0.2%
0.2%
0.1%
0.0%
Average
0.3%
0.3%
0.3%
0.2%
0.2%
0.2%
Apply 110V pp
125KHz Sine wave
(Parallel)
Breakdown Voltage
Series 110 V PP @ 125 kHhz
+ Vb Change
- Vb Change
10.0%
7.5%
5.0%
2.5%
0.0%
-2.5%
-5.0%
-7.5%
-10.0%
10 min
60 min
120 min
10 min
60 min
120 min
Max
0.3%
0.3%
0.3%
0.3%
0.3%
0.3%
Min
0.2%
0.2%
0.2%
-0.2%
0.2%
0.2%
Average
0.3%
0.3%
0.3%
0.2%
0.3%
0.2%
Apply 110V pp
125KHz Sine wave
(Series)