Download

CODE READER FQ-CR SERIES
Exceptional Reading Performance with Easy Operation
Multi Code Reader
FQ-CR1 Series
2D Code Reader for Direct Part Marking codes
FQ-CR2 Series
» Read from everything from paper and labels to metal, PCBs, and glass for a wide range of applications.
2
Solve a variety off different applications with one product series
Read Codes Printed on Paper or Labels
Paper or Cardboard
Multi Code Reader
FQ-CR1 Series
Medical Packs
ITF (Interleaved 2 of 5)
PET Bottles
QR Code
Codebar (NW-7)
Data Matrix
GS1-DataBar
Medication Boxes
JAN/EAN/UPC
FQ-CR1
Reads 14 Different Codes
Many different codes are used for different applications. And for some products, different codes are printed together.
The FQ-CR1 can read many different codes without requiring any changes to its settings.
Barcodes:
Reads 9
JAN/EAN/UPC
Code39
Codabar ( NW-7 )
ITF (Interleaved 2 of 5)
Code93
Code128 / GS1-128
different codes.
GS1-DataBar
GS1-128 Composite Code
Pharmacode
2D codes:
Data Matrix
QR Code
Micro QR Code
PDF417
Micro PDF417
Reads 5
different codes.
• QR code is the registered trademark of DENSO WAVE.
3
There are many instances when different barcode or 2D code systems are used together in the same manufacturing process.
Code printing quality can also vary due to imperfect printing or low contrast.
The FQ-CR Series handles these and many other conditions.
The FQ-CR Series can be easily introduced without using different code readers and
operating procedures for each of the different processes.
2D Code Reader for
Direct Part Marking (DPM) codes
Reads Direct Part Marking (DPM) Codes
FQ-CR2 Series
DPM codes on Resin
Data Matrix
DPM codes on small parts
DPM codes on film or glass
DPM codes on metal
Data Matrix
Data Matrix
Data Matrix
FQ-CR2
Easily reads difficult codes
Just read the code and register it, and then let the following functions automatically tune the settings.
Depending on the conditions of the code, the automatic retry and code error correction functions let, essentially anyone, easily adjust the settings.
Filter function
Retry function
Code Error Correction
Three stages of filtering are automatically
selected for the read image from Smooth, Dilate,
Erosion, and Median filtering.
You can retry the settings until reading is
successful while automatically changing the
exposure time and other reading parameters.
Code omissions and errors are automatically
corrected when the code is read.
Before Dilation
After Dilation
Before Retry
After Retry
Before Processing
After Processing
4
FQ-CR2
OMRON’s Unique Algorithm Provides
Superior Reading Ability for Direct Part Marking codes
Removal of Printing Irregularities or Noise
Filter function
You can apply up to three of the four unique filters developed by OMRON
in the desired order to remove printing irregularities and noise, in order to achieve a stable reading.
Types of Filtering
Smooth
Dilate
Combining Filtering
Smooths the image.
Erosion
For white codes, reduces the cell size.
Effective for reading separated dot codes.
For white codes, increases the cell size.
Effective for reading codes with cell spreading.
Median
Removes noise.
Erosion and dilation can be combined to connect dots without changing the dot thickness.
Dilate
Erosion
5
Reading
Automatic Parameter Adjustment Until Reading is Successful
Retry function
Code Readers must be able to read codes even for poor printing conditions. You can automatically retry reading while changing the exposure time
and other reading conditions, even for changing workpieces or environments, to enable a stable reading.
The following retry functions are provided.
1
Retrying the Specified Number of Times with the Same Conditions
2
Retrying While External Trigger Is Input
3
Retrying While Changing the Shutter Speed
4
NG
NG
OK
Reading is performed the specified number of times for the same scene.
During level trigger input
Reading is performed until successful, as long as an external level trigger is input.
NG
Reading is performed for the same scene while changing the exposure time in stages.
OK
NG
NG
NG
OK
1ms
1.3ms
0.7ms
1.6ms
Retrying While Changing the Reading Conditions
When reading DPM codes, inconsistencies in printing conditions can result
in NGs if reading is performed with only one set of reading settings.
NG
NG
NG
OK
Scene 1
Scene 2
Scene 3
Register 32 sets of reading conditions.
Rapidly switch to the optimum reading conditions.
The FQ-CR allows you to register up to 32 sets of
reading conditions as scenes and retry reading
while changing the scenes in order.
The system automatically determines the scenes
with the highest usage rates and changes the order to start
Scene 2
Scene 4
Scene 6
Scene 8
Scene 32
with them to flexibly handle changes in reading conditions.
Of course you can specify a fixed order if required.
Scene 1
Easy Confirmation of Code Quality
Code Error Correction Position Display
Red circles are displayed on cells
for which the code was corrected on the display.
This clearly shows where the code quality was poor.
Scene 3
Scene 5
Scene 7
Scene 31
6
FQ-CR1
FQ-CR2
Stable Reading Functions Packed into a Compact Body
Polarization filter
Cuts specular reflections.
High power LEDs
Four times the brightness of previous models.
Lens and Camera
simple fine tuning of camera focus.
Actual Size
Decoder
Built-in HDR function.
Robust housing: IP67
Ethernet Output
Output read codes on Ethernet.
7
Detection and Connection
Reads Codes Even with Low Contrast
High-power LEDs
The wider the field of view, the more difficult it is to maintain consistent
lighting within the field, causing errors in reading. The built-in LEDs of
the FQ-CR Series use a unique OMRON DR optical system for effective
light usage to maintain consistent lighting within the field of vision at a
brightness that is four times that of previous models.
Previous Lighting
High-power Lighting
Halation
Stable Detection for
Metal Surfaces Subject to
Gloss and Inconsistent Lighting
Without Polarizing Filter
With Polarizing Filter
Cuts Light Interference
HDR Function
The HDR (high dynamic range) function minimizes the influence of
changes in lighting conditions and light reflection. This enables
stable inspections even for materials that are difficult to light evenly,
such as metal parts or glossy films, or in locations subject to external
light interference.
Cuts Specular Reflections
Polarizing Filter
A polarizing filter is included to cut specular reflection from glossy
surfaces. This enables stable code reading even for metallic or other
glossy surfaces.
Communications with Host Devices
Ethernet Connection
The compact body also provides an Ethernet connector so that you
can transfer read data and images via Ethernet. Smoothly transfer
data to PLCs, computers, or other host devices.
Ethernet
8
FQ-CR1
FQ-CR2
Essentially, Simple Enough for Anyone to Set Up
Setup is as easy as displaying codes on the monitor and registering settings with a simple procedure.
Then, the FQ-CR will automatically tune the settings to achieve the optimum conditions.
You can automatically tune all of these reading conditions just by making the basic settings.
Optimum Tuning in Three Steps
Read a code.
Select the type of code.
Two Set-up Tools
Use the convenient Touch Finder
for on-site settings and control panel installations,
or use a set-up tool on a computer.
Touch Finder
TouchFinder for PC (Free)
After purchasing the Code Reader,
you can
ca download the TouchFinder for PC free from the member’s website.
9
Set-up and Adjustment
Exposure Time
Gain
Press the TEACH Button.
Dynamic Range
Filtering
Check to see if the conditions
are correct as a reference.
END
Menu Displays in Nine Languages
Operation Navigation
The nine language support for menus means
that you can easily introduce systems into
factory sites in other countries.
In addition, you can easily change the language
on a menu.
Navigation menus for operating procedures
from image adjustment through to testing and
starting operation are provided so that even
beginners can operate the Code Reader.
English
German
Japanese
French
Traditional Chinese
Italian
Simplified Chinese
Spanish
Korean
Setup
flow
10
FQ-CR1
FQ-CR2
Flexible System Configuration
Connect Up To Eight Code Readers
The flexibly arrangeable platform can be used for
simple configurations with one Code Reader for
complex configurations with multiple Code Readers
reading from different directions.
Up to eight Code Readers can be controlled from the
Touch Finder set-up console.
Code Quality Management
The FQ-CR2 contains state-of-the-art algorithms that enable the reading of codes even
with poor reading quality. However, even if the code quality continues to deteriorate for
some reason, auto-correction and retrying are used to enable reading, making it
impossible to tell where quality was lost simply from the OK/NG reading information.
Here, you can use the cell recognition rate information. The cell recognition rate changes
with code printing quality, position inconsistency, installation conditions, and noise. You
can log the cell recognition rate and image together to manage quality trends. The
logging of recent results is useful for testing when commissioning a line. Run through
some sample products and log the cell recognition rate. You can then display the results
in a time-based graph to see how much leeway there is in reading performance.
* For the FQ-CR1, the number of detected characters is logged instead of the cell recognition rate.
gging
File Logging
SD Card
Cell recognition rate
Up to 10 million measurement
values or more
(for a 4-GB SD card)
Up to 10,000 images or more
(for a 4-GB SD card)
Loggingg of Recent Results
Displays the most recent 1,000
cell recognition rate in graph form.
11
Commissioning and Operation
Match your field of view No matter whether you handle large or small workpieces, the range of Omron
FQ-CR Code Readers offers a perfect match. Select the FQ-CR model with the
appropriate range and adjust the field of view to your application. Focusing is
quick and easy too, enabling you to use the sensor for a variety of applications.
Field of vision
13
7.5
4.7
38
Narrow view
0
Field of vision
8.2
57
53
33
13
8.2
56
Standard
0
215
240
Field of vision
Touch Finder
153
53
Wide View
(long-distance)
33
220
0
970
300
Field of vision
191
29
Wide View
(short-distance)
TouchFinder for PC
Automatic Notification of NGs
If you leave the Touch Finder installed on-site, the
recent NG sensor display is very useful. Even if you
are monitoring more than one Code Reader with
the Touch Finder, the display automatically
changes to the Code Reader where an NG occurred
so that you can quickly confirm conditions.
!
18
0
32
380
12
System Configuration
Connections for One Code Reader
Control by parallel input/output
Control by Ethernet
FQ-CR
Code Reader
Touch Finder
FQ-CR Ethernet Cables
I/O Cables
FQ-CR
Code Reader
Sensor trigger
Switching
Hub
Touch Finder
Sensor trigger
PLC
Power Supply 24 VDC
FQ-CR Ethernet Cables
Power Supply 24 VDC
I/O Cables
Standard Ethernet Cables
(RJ-45 of the FCC regulations)
PLC
Standard Ethernet Cables
(RJ-45 of the FCC regulations)
Connections for Multiple Code Reader
Control by parallel input/output
Control by Ethernet
Up to 32 Code Reader can be connected.
Up to 32 Code Reader can be connected.
FQ-CR Ethernet Cables
Touch Finder
Switching
Hub
Touch Finder
Standard Ethernet Cables
(RJ-45 of the FCC regulations)
Connect the trigger
sensor, power supply
to each Code Reader.
FQ-CR Ethernet Cables
Switching
Hub
Standard Ethernet Cables
(RJ-45 of the FCC regulations)
Standard Ethernet Cables
(RJ-45 of the FCC regulations)
Connect the trigger
sensor, power supply
to each Code Reader.
PLC
Note: If you register as a member after purchasing a Code Reader, you can download the free set-up software TouchFinder for PC that runs on
a PC and can be used in place of the Touch Finder. Refer to the member registration sheet for details.
Ordering Information
Code Reader
Narrow View
Standard
(Unit: mm)
Wide View
(Short-distance)
(Long-distance)
300
240
Field of vision
Field of vision
7.5
8.2
56
0
2D Code
Reader
33
13
8.2
4.7
57
38 to
0
53
Field of vision
13
Multi Code
Reader
53
2D Code
Reader
Multi Code
Reader
970
18
32
to
220
0
191
29
33
215
to
153
Field of vision
0
2D Code
Reader
Multi Code
Reader
2D Code
Reader
380
to
Multi Code
Reader
NPN FQ-CR20010F-M FQ-CR10010F-M
NPN FQ-CR20050F-M FQ-CR10050F-M
NPN FQ-CR20100F-M FQ-CR10100F-M
NPN FQ-CR20100N-M FQ-CR10100N-M
PNP FQ-CR25010F-M FQ-CR15010F-M
PNP FQ-CR25050F-M FQ-CR15050F-M
PNP FQ-CR25100F-M FQ-CR15100F-M
PNP FQ-CR25100N-M FQ-CR15100N-M
Note: Tolerance (field of vision): ±10% max.
Touch Finder
Accessories
Type
Model
DC power supply
FQ2-D30
AC/DC/battery
FQ2-D31 (See note.)
Note: AC Adapter and Battery are sold separately.
For Code
Reader
Cables (Robot cable)
Type
Cable length
FQ Ethernet Cables
(connect Code Reader to Touch
Finder, Code Reader to PC)
I/O Cables
Application
Model
2m
FQ-WN002
10 m
FQ-WN010
20 m
FQ-WN020
2m
FQ-WD002
10 m
FQ-WD010
20 m
FQ-WD020
Industrial Switching Hubs (Recommended)
Appearance
Number
of ports
3
5
Failure
detection
None
None
Supported
Current
consumption
0.22 A
0.22 A
Model
For Touch
Finder
Appearance
Name
Model
Mounting Bracket
(enclosed with Code Reader)
FQ-XL
Mounting Bracket for
highprecision sensing *1
(sold separately)
FQ-XL2
Polarizing Filter Attachment
(enclosed with Code Reader)
FQ-XF1
Panel Mounting Adapter
FQ-XPM
AC Adapter
(for models for DC/AC/Battery)
FQ-AC1
Battery *2
(for models for DC/AC/Battery)
FQ-BAT1
Touch Pen
(enclosed with Touch Finder)
FQ-XT
Strap
FQ-XH
SD Card (2 GB)
HMC-SD291
W4S1-03B
W4S1-05B
W4S1-05C
*1. A mounting Bracket with improved resistance to vibrations and other external
stresses that cause displacement of the optical axis and field of view.
*2. The Battery uses a lithium ion secondary battery. Confirm any applicable
laws and regulations in the destination country if you export the Battery.
13
Ratings and Performance
Code Reader
Item
Type
Model
2D Code Reader
Multi Code Reader
NPN
FQ-CR20@@@@-M
FQ-CR10@@@@-M
PNP
FQ-CR25@@@@-M
FQ-CR15@@@@-M
Field of vision
Refer to the table below.
Installation distance
FQ-CR2@010F-M/-CR1@010F-M: 0.040 mm FQ-CR2@050F-M/-CR1@050F-M: 0.070 mm
FQ-CR2@100F-M/-CR1@100F-M: 0.282 mm FQ-CR2@100N-M/-CR1@100N-M: 0.155 mm
Minimum resolution
2D Code (DataMatrix (EC200), QR Code, MicroQR
Code, PDF417, MicroPDF417, GS1-DataMatrix)
Bar code (JAN/EAN/UPC, Code39,
Codabar (NW-7), ITF (Interleaved 2 of 5),
Code 93, Code128/GS1-128, GS1 DataBar*
(Truncated, Stacked, Omni-directional, Stacked
Omni-directional, Limited, Expanded and Expanded
Stacked), Pharmacode and GS1-128 Composite
Code (CC-A, CC-B, CC-C))
Code
2D Code (DataMatrix (EC200), QR Code)
Image filter
Filter function (Smooth, Dilate, Erosion,Median),
Retry function, Code Error Correction Position
Display
None
Verification function
None
Supported
Number of simultaneous
inspections
32
Number of registered scenes
32
Image filter
High dynamic range (HDR), polarizing filter (attachment)
Image elements
1/3-inch monochrome CMOS
Shutter
1/250 to 1/32,258 s
Processing resolution
752 × 480
Lighting method
Pulse
Lighting color
White
LED class
Risk Group 2 (IEC62471)
Measurement data
In Code Reader:1,000 items (If a Touch Finder is used, results can be saved up to the capacity of an SD card.)
Images
In Code Reader:20 images (If a Touch Finder is used, images can be saved up to the capacity of an SD card.)
Main functions
Image input
Lighting
Data logging
Measurement trigger
I/O
specifications
Ratings
1/250 to 1/30,000 s
External trigger (single or continuous)
Input signals
7 signals
• Single measurement input (TRIG)
• Control command inputs (IN0 to IN5)
Output signals
3 signals
• Control output (BUSY)
• Overall judgement output (OR)
• Error output (ERROR)
Note: The three output signals can be allocated for the judgements of individual inspection items.
Ethernet specification
Numerical outputs and control commands are supported with no-protocol communications.
100BASE-TX/10BASE-T
Connection method
Special connector cables
• Power supply and I/O:
1 cable (FQ-WD@@@)
• Touch Finder and computer: 1 cable (FQ-WN@@@)
Power supply voltage
21.6 to 26.4 VDC (including ripple)
Current consumption
2.4 A max.
Ambient temperature range
Operating: 0 to 50°C
Storage: −25 to 65°C
(with no icing or condensation)
Environmental
Ambient humidity range
immunity
Ambient atmosphere
Operating and storage: 35% to 85% (with no condensation)
No corrosive gas
Degree of protection
IEC 60529 IP67 (Except when Polarizing Filter Attachment is mounted.)
Code Reader:
Mounting Bracket:
Polarizing Filter Attachment:
Ethernet connector:
I/O connector:
Materials
• Mounting Bracket (FQ-XL) (1)
• Polarizing Filter Attachment (FQ-XF1) (1)
• Instruction Manual
Accessories
2D Code Reader
NPN
PBT, PC, SUS
PBT
PBT, PC
Oil-resistance vinyl compound
Lead-free heat-resistant PVC
PNP
Multi Code Reader
NPN
PNP
Field of view
(See note)
(Horizontal × Vertical)
• Member registration sheet
Installation distance
FQ-CR20010F-M
FQ-CR25010F-M FQ-CR10010F-M FQ-CR15010F-M 7.5 × 4.7 to 13 × 8.2 mm
FQ-CR20050F-M
FQ-CR25050F-M FQ-CR10050F-M FQ-CR15050F-M 13 × 8.2 to 53 × 33 mm
56 to 215 mm
FQ-CR20100F-M
FQ-CR25100F-M FQ-CR10100F-M FQ-CR15100F-M 53 × 33 to 240 × 153 mm
Long-distance model: 220 to 970 mm
FQ-CR20100N-M FQ-CR25100N-M FQ-CR10100N-M FQ-CR15100N-M 29 × 18 to 300 × 191 mm
Note: Tolerance: ±10% max.
Weight
38 to 57 mm
Short-distance model: 32 to 380 mm
200 g max.
14
Touch Finder
Type
Item
Model with AC/DC/battery power supply
FQ2-D30
FQ2-D31
Number of sensors that can be recognized (switched): 32 max. number or sensor that can displayed on
monitor: 8 max.
Number of connectable Sensor
Main functions
Model with DC power supply
Model
Types of measurement displays
Last result display, Last NG display, trend monitor, histograms
Types of display images
Through, frozen, zoom-in, and zoom-out images
Data logging
Measurement results, measured images
Menu language
English, German, French, Italian, Spanish, Traditional Chinese, Simplified Chinese, Korean, Japanese
LCD
Indications
Backlight
Display device
3.5-inch TFT color LCD
Pixels
320 × 240
Display colors
16.7 million
Life expectancy *1
50,000 hours at 25ºC
Brightness adjustment
Provided
Screen saver
Provided
Method
Resistance film
Operation
interface
Touch
screen
External
interface
Ethernet
100BASE-TX/10BASE-T
SD card
SDHC-compliant, Class 4 or higher recommended
Power supply voltage
DC power connection:21.6 to 26.4 VDC
(including ripple)
Life expectancy *2
1,000,000 touch operations
DC power connection: 21.6 to 26.4 VDC
(including ripple)
AC adapter (manufactured by Sino-American Japan
Co., Ltd) connection: 100 to 240 VAC, 50/60 Hz
Battery connection: FQ-BAT1 Battery (1cell, 3.7 V)
Ratings
Continuous operation on Battery *3
Environmental
immunity
---
1.5 h
Power consumption
DC power connection: 0.2 A max.
DC power connection: 0.2 A max.
Charging battery:
0.4 A max.
Ambient temperature range
Operating: 0 to 50ºC
Storage: −25 to 65ºC
(with no icing or condensation)
Operating: 0 to 50ºC when mounted to DIN Track or panel
Operation on Battery: 0 to 40ºC
Storage:
−25 to 65ºC
(with no icing or condensation)
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
Ambient atmosphere
No corrosive gas
Vibration resistance (destruction)
10 to 150 Hz, single amplitude: 0.35 mm, X/Y/Z directions
8 min each, 10 times
Shock resistance (destruction)
150 m/s2 3 times each in 6 direction (up, down, right, left, forward, and backward)
Degree of protection
IEC 60529 IP20 (when SD card cover, connector cap, or harness is attached)
Weight
Approx. 270 g (without Battery and hand strap attached)
Materials
Case: ABS
Accessories included with Touch Finder
Touch Pen (FQ-XT), Instruction Manual
*1. This is a guideline for the time required for the brightness to diminish to half the initial brightness at room temperature and humidity. The life of the backlight is
greatly affected by the ambient temperature and humidity and will be shorter at lower or higher temperatures.
*2. This value is only a guideline. No guarantee is implied. The value will be affected by operating conditions.
*3. This value is only a guideline. No guarantee is implied. The value will be affected by the operating environment and operating conditions.
Battery Specifications
Item
Model
FQ-BAT1
Battery type
Secondary lithium ion battery
Nominal capacity
1,800 mAh
Rated voltage
3.7 V
Ambient temperature range
Operating: 0 to 40ºC
Storage: −25 to 65ºC (with no icing or condensation)
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
Charging method
Charged in Touch Finder (FQ-D31). AC adapter (FQ-AC@) is required.
Charging time (See note 1.)
2h
Battery backup life (See note 2.)
300 charging cycles
Weight
50 g max.
Note: 1. This value is only a guideline. No guarantee is implied. The value will be affected by operating conditions
2. This is a guideline for the time required for the capacity of the Battery to be reduced to 60% of the initial capacity. No guarantee is implied.
The value will be affected by the operating environment and operating conditions.
System Requirements for TouchFinder for PC
The following Personal Computer system is required to use the software.
OS
Microsoft Windows XP Home Edition/Professional SP2 or higher (See note 1.)
Microsoft Windows 7 Home Premium or higher (See note 1.)
CPU
Core 2 Duo 1.06 GHz or the equivalent or higher
RAM
1GB min.
HDD
500 MB min. available space (See note 2.)
Monitor
1,024 × 768 dots min.
Note: 1. The Japanese and English versions support only 32-bit OS versions.
2. Available space is also required separately for data logging.
Dimensions
(Unit: mm)
Code Reader (Dimensional drawings are provided here only for the products that have undergone design changes as of June 2012.)
FQ-CR
Mounting with the FQ-XL2 Mounting Bracket
Mounting with the FQ-XL Mounting Bracket
(57)
Optical axis
45
40
30
67
5
(108)
1
OPTICAL
AXIS
Plate
8
Cushion
18
(See note 1.)
1/4-20UNC
Depth: 6
Four-M4
Depth: 6
9
32
Polarizing
Filter Attachment
(108)
67
59
20±0.1
(65)
Mounting Bracket
20±0.1
38.8
46
Four machine screws
(double pan-head set screws)
t1 Base
Mounting Hole Dimensions
38
(See note 2.)
41
38
Two, 4.5 dia.
20±0.1
20±0.1
Mounting Hole Dimensions
8
49
Two, 4.5 dia.
Tightening torque: 1.2 N.m
* Dimentions with the FQ-XL Mounting Bracket
Type
Model
Note 1.
Note 2.
Narrow View,
Standard
FQ-CR1@010F-M/-CR2@010F-M/
-CR1@050F-M/-CR2@050F-M
11
57
Wide View
FQ-CR1@100F-M/-CR2@0100F-M/
-CR1@100N-M/-CR2@100N-M
3
49
Touch Finder
FQ2-D30/-D31
Panel Mounting Adapter
(36.9)
(2)
31.6
20
3.5
116
95
44.5
95
(See note.)
27.9
85
85
23.8
14
52.9
35.5
(133.4)
70
116
33
(8.1)
12.1
Panel Cutout Dimensions
13.5
15
111±1
27
111±1
17.3
19.2
10
(See note.)
Note: Provided with FQ2-D31 only.
Panel
15
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of
sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR
PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED
WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S
ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO
CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF
PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate
catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use
of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This
information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other
application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the
products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment,
and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A
WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED
USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of
OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of
Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some
specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your
application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or
proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any
manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69-2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2011 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
CSM_14_1_0615
Cat. No. Q186-E1-01
0811 (0811)