ISSUE #3 Switch-mode and uninterruptible power supplies Core Assortment Catalogue 2015 Australia & New Zealand www.weidmuller.com.au Would you accept a power failure in your application? Our power supply solutions are never-ending! Machinery Transportation INSTAPOWER PRO-E PROeco For applications wherever space and efficiency is the overall requirement For OEM applications where DIN rail is not used For General purpose applications •• Building •• Very small control cabinets for machinery •• Terminal boxes •• Consumer machines •• Electronic signs •• Custom design •• Process (e.g Instrumentation) •• Machinery (e.g. control system) •• Energy (e.g. SCADA system) •• Transportation (e.g. signalling) DIN rail mount Page 20 Chassis mount Page 18 DIN rail mount Page 8 Energy Process PROmax DC UPS PRO-H Use in demanding applications where varying loads or high temperatures exist Energy Storage to bridge 24VDC supplies during mains power interruptions For applications where reliability is paramount. Active redundancy with ATEX approvals. •• Process (e.g. Water treatment) •• Machinery (e.g. Conveying systems) •• Energy (e.g. Renewable energy) •• Transportation •• Process (e.g. Water treatment) •• Machinery (e.g. Conveying systems) •• Energy (e.g. Renewable energy) •• Transportation •• Process (Oil & Gas, chemical) •• Energy DIN rail mount Page 10 DIN rail mount Page 12 DIN rail mount Page 16 Find the perfect product to meet your requirement Our extensive portfolio of power supplies at a glance NO = NO contact CO = CO contact Start-up @ –40°C = In the range of –40 to –25°C the device starts, but some technical parameter may differ (i. e., ripple-voltage). % u % ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Order No. Marine engineering ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Power distribution ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Simple process applications ● ● ● ● ● ● ● ● ● ● ● ● ● Energy technology % ● ● ● ● ● ● ● ● ● ● ● ● ● Process industry ● 87 ● 87 ● 90 ● 91 ● 93 ● 87 –25 ● 88 > 0.5 II to ● +70 89 ● 90 ● 90 ● 90 ● 90 ● 90 ● 90 ● 90 ● 91 ● 91 ● –25 91.5 ● to 92.5 ● 90 +70 ● 91 > 0.5 III ● 91.5 SEMI F47 ● Start-up 92.5 @ ● 86 ● –40°C 89 ● 89 Cl1Div2 ● 91 ● 91.5 Some not yet awarded ● 92.5 (status July 2014) 82 85 85 85 88 87 –25 89 to > 1.8 II 87 +70 90 89 91 88 Cl1Div2 88 88 Machine construction and plant manufacture Approvals Surge category MTBF time [Mh] Efficiency [%] Temperature range [°C] Side-by-side connectability Status relay Power boost [60 s] Derating at [°C] Power rating [V] Rated current [A] NO 24 3 72 NO 24 5 120 NO 24 10 240 NO 24 20 480 NO 24 40 960 NO 24 5 120 NO 24 10 240 > 55 NO 24 20 480 NO 24 40 960 NO 12 6 72 NO 12 10 120 NO 48 5 240 NO 48 10 480 CO 24 3 72 CO 24 5 120 CO 24 7.5 180 CO 24 10 240 CO 24 20 480 CO 24 40 960 24 5 120 120% CO CO 24 10 240 > 60 300% CO 24 20 480 @ 1 s CO 24 40 960 CO 5 14 70 CO 12 6 72 CO 12 10 120 CO 48 5 240 CO 48 10 480 CO 48 20 960 NO 12 6 70 NO 12 12 140 NO 24 3.8 90 NO 24 3.8 90 NO 24 7.5 180 NO 24 15 360 NO 24 25 600 > 40 NO 48 2 96 NO 48 4 192 NO 48 7.5 360 NO 48 12.5 600 NO 24 7.5 180 NO 24 15 360 NO 24 25 600 Recommendation for application Field cabinets 80–370 80–370 80–370 80–370 80–370 450–870 450–870 450–870 450–870 80–370 80–370 80–370 80–370 80–370 80–370 80–370 80–370 80–370 80–370 450–800 450–800 450–800 450–800 80–370 80–370 80–370 80–370 80–370 80–370 n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a n/a Additional functions Small and series machine construction 85–264 85–264 85–264 85–264 85–264 340–575 340–575 340–575 340–575 85–264 85–264 85–264 85–264 85–277 85–277 85–277 85–277 85–277 85–277 3 x 320–3 x 575 3 x 320–3 x 575 3 x 320–3 x 575 3 x 320–3 x 575 85–277 85–277 85–277 85–277 85–277 85–277 85–264 85–132/187–264 85–264 85–264 85–132/187–264 85–132/187–264 85–132/187–264 85–264 85–132/187–264 85–132/187–264 85–132/187–264 85–132/187–550 85–132/187–550 85–132/187–550 Rated voltage [V] 1 1 1 1 1 3 3 3 3 1 1 1 1 1 1 1 1 1 1 3 3 3 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 1.2 1.2 Output side DC input voltage [V] PRO ECO 72 W 24 V 3 A PRO ECO 120 W 24 V 5 A PRO ECO 240 W 24 V 10 A PRO ECO 480 W 24 V 20 A PRO ECO 960 W 24 V 40 A PRO ECO3 120 W 24 V 5 A PRO ECO3 240 W 24 V 10 A PRO ECO3 480 W 24 V 20 A PRO ECO3 960 W 24 V 40 A PRO ECO 72 W 12 V 6 A PRO ECO 120 W 12 V 10 A PRO ECO 240 W 48 V 5 A PRO ECO 480 W 48 V 10 A PRO MAX 72 W 24 V 3 A PRO MAX 120 W 24 V 5 A PRO MAX 180 W 24 V 7,5 A PRO MAX 240 W 24 V 10 A PRO MAX 480 W 24 V 20 A PRO MAX 960 W 24 V 40 A PRO MAX3 120 W 24 V 5 A PRO MAX3 240 W 24 V 10 A PRO MAX3 480 W 24 V 20 A PRO MAX3 960 W 24 V 40 A PRO MAX 70 W 5 V 14 A PRO MAX 72 W 12 V 6 A PRO MAX 120 W 12 V 10 A PRO MAX 240 W 48 V 5 A PRO MAX 480 W 48 V 10 A PRO MAX 960 W 48 V 20 A CP T SNT 70 W 12 V 6 A CP T SNT 140 W 12 V 12 A CP T SNT 90 W 24 V 3.8 A CP T SNT 90 W 24 V 3.8 A CL2 CP T SNT 180 W 24 V 7.5 A CP T SNT 360 W 24 V 15 A CP T SNT 600 W 24 V 25 A CP T SNT 90 W 48 V 2 A CP T SNT 180 W 48 V 4 A CP T SNT 360 W 48 V 7.5 A CP T SNT 600 W 48 V 12.5 A CP T SNT2 180 W 24 V 7.5 A CP T SNT2 360 W 24 V 15 A CP T SNT2 600 W 24 V 25 A AC input voltage [V] Phases Input side Description PRO-H PROmax PROeco Series / family ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 1469470000 1469480000 1469490000 1469510000 1469520000 1469530000 1469540000 1469550000 1469560000 1469570000 1469580000 1469590000 1469610000 1478100000 1478110000 1478120000 1478130000 1478140000 1478150000 1478170000 1478180000 1478190000 1478200000 1478210000 1478220000 1478230000 1478240000 1478250000 1478270000 1105430000 1105440000 1105790000 1194410000 1105810000 1105820000 1105840000 1194420000 1105850000 1105860000 1105870000 1194480000 1194490000 1194310000 INSTAPOWER Supplementary modules UPS CP DC BUFFER 24 V 20 A Status relay Parallel connection option Side-by-side connectability 24 22.5–29.5 10 240 ● ≤5 ● 22.5–30 24 20 1313320010 –25 to +70 480 ● ● ● 1370050010 ● 1370040010 CP DC UPS 24 V 20 A/10 A 20–30 Uin–0.3 V 20/10 480/240 ● CP DC UPS 24 V 40 A 20–30 Uin–0.3 V 40 960 ● 24 24 24 24 24 10 A / 11.3 min. 10 A / 11.3 min. 10 A / 26.5 min. 10 A / 51 min. 10 A / 81 min. 1.3 Ah 3.4 Ah 7.2 Ah 12 Ah 17 Ah CP A BATTERY 24 V DC 1,3 Ah CP A BATTERY 24 V DC 3,4 Ah CP A BATTERY 24 V DC 7,2 Ah CP A BATTERY 24 V DC 12 Ah CP A BATTERY 24 V DC 17 Ah Order No. Approvals (all CE) Power rating [W] 18–31.2 Temperature range [°C] Rated current [A] Additional functions Adjustable range [V] CP DCDC 250 W 24 V 10 A Output Rated voltage [V] AC input voltage [V] Input DC input voltage [V] DC/DC Description Series / family ≤2 ≤2 ≤2 ≤2 ≤2 ● ● ● ● ● CP T RM 10 (PRO-H redundancy module) 24 24 24–27 15 ● CP T RM 20 (PRO-H redundancy module) 24 24 24–27 25 ● CP DM 10 (diode module) 10–40 UIN–0.7 10 CP DM 20 (diode module) 10–40 UIN–0.7 20 CP M DM 20 (diode module) 18–30 UIN–0.7 20 ● ≤5 ● CP M DM 40 (diode module) 18–30 UIN–0.7 40 ● ≤5 ● CP M CAP (capacity module) 18–30 UIN 40 A/1 ms ● ≤5 ● 1 1 1.5 1.5 2 28 24 22.5 18 10 0 to +40 –25 to +70 –10 to +55 ● ● ● ● ● CP SNT 24 W 28 V 1 A CP SNT 24 W 24 V 1 A CP SNT 24 W 15 V 1,5 A CP SNT 24 W 12 V 1,5 A CP SNT 24 W 5 V 2 A 85–265 85–265 85–265 85–265 85–265 120–300 120–300 120–300 120–300 120–300 28 24 15 12 5 CP SNT 25 W 5 V 5 A 85–264 110–370 5 4–8 5 25 ≤3 ● CP SNT 48 W 12 V 4 A 85–264 110–370 12 9–15 4 48 ≤3 ● CP SNT 48 W 24 V 2 A 85–264 110–370 24 15–28 2 48 ≤3 ● CP SNT 48 W 48 V 1A 85–264 110–370 48 46–55 1 48 ≤3 ● 1251220000 1406930000 1251070000 1251080000 1251090000 1251110000 1105880000 1105890000 8710620000 8768650000 1222210000 –25 to +70 1222220000 1222240000 –20 to +50 9928890028 9928890024 9928890015 9928890012 9928890005 8754960000 –10 to +70 8754970000 8739140000 8879230000 We cannot guarantee that the publications or software we provide to customers for the purpose of placing orders are completely free of errors. We make every effort to correct such errors once we become aware of them. Product Overview Power Supply Distribution As an industrial connectivity partner, Weidmüller offers you power supply solutions in a variety of reliability levels – which accurately fit into your application right down to the very last detail. Input/supply Lightning and surge protection AC distribution Switched-mode power supply units PROeco Upstream protective circuit for the AC input: modular terminals for a flexible connection to the mains and our VARITECTOR lightning and surge protectors for supplementary or complete protection of your power supply. PROmax Expansion modules PRO-H Diode module System components Capacity module The correct switched-mode power supply unit is an essential element of a permanently reliable cabinet and supplies the fuel for all the automation equipment. The expansion modules allow you to supplement individual functions. Electronic fuse Depending on which requirements the devices in your automation have and how they are protected or supported in a customised manner, the system components turn your power supply into a solution for your application. Uninterruptible power supply (UPS) Distribution DC/DC converters WAVEGUARD PRV Terminal Distribution of the DC control voltages for the individual consumer paths. Control energy distribution Marshalling and potential distribution Contents Power Supplies 8 NEW PROeco 16 • High reliability in a compact size. • 12 - 48V, 72 – 960W • 1 or 3 phase operation 10 NEW PROmax • High performance with extended life • 12-48V, 70-600W • Active redundancy system 18 DC UPS and Battery Modules 20 • Secure DC energy for automation • Intuitive UPS • High quality battery system 14 DC Buffer Module DC/DC converter • Isolate and regulate 24V DC power Weidmüller product portfolio Weidmüller offers a comprehensive range of products for electrical connectivity, transmission and conditioning of power, signal and data in industrial environments. See our website at www.weidmuller.com.au for more information about our products. INSTAPOWER • Powerful and efficient in small spaces • Din Rail mount • 25-48W 21 • Maintenance free power storage • Short duration with high operating temperature 15 NEW PRO-E • Power for alternative systems • Plate mount • 5-48V, 25-350W • Maximum power with minimal size • 5 - 48V, 72 – 960W • 1, 2 or, 3 phase operation 12 PRO-H Electronic Fusing • Electronic fusing with advantages • Fast switching, local and remote reset 21 Fuse Terminals • Overload and short-circuit protection Power Supply Selection Considerations/Glossary For Power Supply Applications and Glossary please see pages 22-26. Switched-mode power supply units connectPower PROeco NEW Tackle your power supply economically PROeco bundles all of the basic functions in a compact design Noticeably energy-saving A high degree of efficiency of up to 93 % and minimal no-load losses ensure low energy consumption and a long service life. A B C 93 % Rapid status diagnosis The tricolour LED display and an integrated status relay make it easier to analyse statuses and errors during commissioning and operation. D Robust and reliable PROeco power packs work reliably in a wide temperature range from –25 °C to +70 °C and boast a high MTBF value of more than 500,000 hours. Extremely compact With a max. depth of 120 mm, PROeco power supplies even fit into small cabinets. The compact design also saves up to 50 % space in the cabinet. 8 Power supply solution Together with the uninterruptible DC USP, the diode modules or CAP modules, you can create a power supply solution that is tailored to your requirements. WAUS Power Supplies Core Assortment Catalogue 2015 Australia & New Zealand Switched-mode power supply units connectPower PROeco PROeco power supplies With basic functionality and a high level of reliability Provides a complete range •• Single and three-phase switch-mode power supply units •• 12V, 24V, 48V models •• Slim design •• Large temperature range from –25 °C to 70 °C •• The output voltage can be precisely adjusted via the multi turn potentiometer on the front •• Remote monitoring via integrated status relay •• Tricoloured LED indicators for simple error detection •• Advanced visual warning at 90 % and 100% rated output •• International approvals: CE; TÜV (EN/IEC 60950-1); cULus, RCM Ambient temp. operating –25 °C…+70 °C Storage temperature Max. perm. air humidity (operation) Degree of protection Class of protection Pollution degree Insulation voltage input/output MTBF Parallel connection option Housing version –40 °C…+85 °C 5 %…95 % RH IP 20 I, with PE connection 2 3 kV E/A / 2 kV E/earth / 0.5 kV A/earth > 500.000 h acc. to IEC 1709 (SN29500) yes, max. 5 without diode module metal, corrosion resistant Mounting position, installation notice horizontal on mounting rail TS 35, 50 mm spacing top and bottom for free air circulation Short-circuit protection Overload protection Yes, automatic restart Yes, IU characteristic curve Overtemperature protection Yes, automatic restart EMC / shock / vibration Noise emission acc. to EN55022 Class B Noise immunity tests acc. to EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN61000-4-6 (conducted), EN61000-4-11 (Dips) Limiting of mains voltage harmonic currents Acc. to EN61000-3-2 Resistance against vibration and shock 1 g acc. to EN50178, shock: 15 g in all directions Electrical safety (applied standards) \ Derating curves Electrical equipment of machines Acc. to EN60204 Safety transformers for switched-mode power units Acc. to EN61558-2-17 Machinery with electronic equipment Acc. to EN50178 / VDE0160 Safety extra-low voltage Protective separation Protection against electrical shock SELV acc. to EN60950-1, PELV acc. to EN60204-1 VDE0100-410 Acc. to DIN57100-410 Protection against dangerous shock currents Acc. to VDE0106-101 Note: Adjustable output voltage - 12V: 10...16V, 24V: 22...28V, 48V: 42...56V ≤ 480 Watt 120 100 100 80 80 60 40 60 40 20 20 0 –25 960 Watt 120 Ioutput (% IN) General technical data Ioutput (% IN) Technical data % 0 20 30 40 50 Ambient temperature (°C) 60 70 0 –25 0 20 30 40 50 Ambient temperature (°C) 70 PROeco Ordering Data Single-phase N. Voltage N. Current PRO ECO 72W 24V 3A PRO ECO 120W 24V 5A PRO ECO 240W 24V 10A PRO ECO 480W 24V 20A PRO ECO 960W 24V 40A PRO ECO 72W 12V 6A PRO ECO 120W 12V 10A PRO ECO 240W 48V 5A PRO ECO 480W 48V 10A Three-phase PRO ECO3 120W 24V 5A PRO ECO3 240W 24V 10A PRO ECO3 480W 24V 20A PRO ECO3 960W 24V 40A Diode module 24V only CP DM 10 2 x 10 A CP DM 20 2 x 20 A / 1 x 40 A 60 H x W x D/ Weight 125/34/100 mm/ 0.5 kg 125/40/100 mm/ 0.6 kg 125/60/100 mm/ 1 kg 125/100/120 mm/ 1.6 kg 125/160/120 mm/ 2.9 kg 125/34/100 mm/ 0.6 kg 125/40/100 mm / 0.7 kg 125/60/100 mm / 1 kg 125/100/120 mm/ 1.6 kg 1469470000 1469480000 1469490000 1469510000 1469520000 1469570000 1469580000 1469590000 1469610000 125/40/100 mm/ 0.6 kg 125/60/100 mm / 1 kg 125/100/120 mm/ 1.3 kg 125/160/120 mm/ 2.5 kg 1469530000 1469540000 1469550000 1469560000 125/55.5/110 mm/ 399 g 125/55.5/110 mm/ 411 g 8710620000 8768650000 *N. = Nominal 9 connectPower PROmax switched-mode power supply unit NEW Powerful power supply for machines and systems PROmax offers flexible solutions for ambitious automation Space-saving width With extremely small width and direct side-by-side fitting, minimal space is required on the DIN rail. Robust and reliable supply MTBF values exceeding 500,000 hours and a wide temperature range of –25 °C to +70 °C ensure reliable supply of the systems. Start-up temperatures of –40 °C make the PROmax particularly robust. Universal application Variants with 3 A to 40 A output current, output voltages of 5 V DC to 48 V DC and numerous approvals (e.g. GL, UL, Class I, Div. 2) enable universal application solutions the world over. Powerful Continuous output power of up to 120 % at temperatures up to +45 °C and high output peaks up to 300 % ensure safe operation, also at the limits. Surge protection devices VARITECTOR PU - Class II power protection for individual consumers - offers protection against surge voltages for supplying industrial production. For more information see CAT 4.4 10 WAUS Power Supplies Core Assortment Catalogue 2015 Australia & New Zealand connectPower PROmax switched-mode power supply unit PROmax power to outperform Offers flexible solutions for ambitious automation Powerful supply for machines and systems •• Single and two/three phase models •• 5V, 12V, 24V, 48 V models •• High power reserves up to 60°C and a start-up at -40°C for safe operation •• Robust thanks to an input voltage range of up to 277 V AC, surge protection category III and SEMI F47 •• Side-by-side connectability and a very thin design to save space in the cabinet •• International approvals guarantee an international use SEMIF47 u (EMC1) Cl. I Div. 2 General technical data Derating curves Current limiting > 120 % IN Insulation voltage input earth Insulation voltage output earth Insulation voltage input/output Earth leakage current Series switching capability Ambient temp. operating Storage temperature Start up Humidity at operating temperature Class of protection Pollution degree MTBF Housing version 3.5 kV 0.5 kV 4 kV 3.5 mA Yes -25 °C...+70 °C (derating @ 60 °C) -40 °C...+85 °C ≥ -40 °C 5...95 %, no condensation 1 2 >500,000h (25°C, IEC 61709) Metal, corrosion resistant Status indication LED red/green and relay (≥21.6 V DC LED green, relay on/ ≤20.6 LED red, relay off) Mounting position, installation notice Horizontal on TS35 mounting rail, with 50 mm of clearance at top and bottom for air circulation. Can be mounted side by side with no space in between. EMC / shock / vibration Noise immunity tests acc. to EN55024; EN55022; IEC61000-3-2,-3; IEC61000-4-2,-3,-4,-5,-6,-8,-11 Resistance against vibration and shock 2.3 g / 30 g in all directions Electrical safety (applied standards) Electrical equipment of machines Acc. to EN60204 Safety transformers for switched-mode power units Acc. to EN61558-2-16 Machinery with electronic equipment Acc. to EN50178 / VDE0160 Safety extra-low voltage SELV acc. to EN60950, PELV acc. to EN60204, IEC61204 Protective separation Protection against electrical shock VDE0100-410 Acc. to DIN57100-410 Protection against dangerous shock currents Acc. to VDE0106-101 Note: Adjustable output voltage - 5V: 4.5...7V, 12V: 10...15V, 24V: 22.5...29.5V, 48V: 30...56V Max. limiting average on state current [A] /RDG Technical data 7HPS& Typ\Temp. 45°C 1ph 24V/3A 3.6 1ph 24V/5A 6 1ph 24V/7.5A 9 1ph 24V/10A 12 1ph 24V/20A 24 1ph 24V/40A 48 1ph 5V/14A 16.8 1ph 12V/6A 7.2 1ph 12V/10A 12 1ph 48V/5A 6 1ph 48V/10A 12 1ph 48V/20A 24 3ph 24V/5A 6 3ph 24V/10A 12 3ph 24V/20A 24 3ph 24V/40A 48 50°C 3.3 5.7 8.5 11.3 22.6 45.2 15.8 6.8 11.3 5.7 11.3 22.6 5.7 11.3 22.6 45.2 55°C 3.2 5.4 8 10.7 21.4 42.8 15 6.4 10.7 5.4 10.7 21.4 5.4 10.7 21.4 42.8 65°C 2.6 4.4 6.6 8.8 17.6 35.2 12.3 5.3 8.8 4.4 8.8 17.6 4.4 8.8 17.6 35.2 70°C 2.2 3.8 5.6 7.5 15 30 10.5 4.5 7.5 3.8 7.5 15 3.8 7.5 15 30 PROmax Ordering Data Single-phase N. Voltage N. Current PRO MAX 72W 24V 3A PRO MAX 120W 24V 5A PRO MAX 180W 24V 7.5A PRO MAX 240W 24V 10A PRO MAX 480W 24V 20A PRO MAX 960W 24V 40A PRO MAX 70W 5V 14A PRO MAX 72W 12V 6A PRO MAX 120W 12V 10A PRO MAX 240W 48V 5A PRO MAX 480W 48V 10A PRO MAX 960W 48V 20A 2/3-phase PRO MAX3 120W 24V 5A PRO MAX3 240W 24V 10A PRO MAX3 480W 24V 20A PRO MAX3 960W 24V 40A Diode module 24V only CP M DM20 2 x 10 A CP M DM40 2 x 20 A / 1 x 40 A *N. = Nominal 60°C 3 5 7,5 10 20 40 14 6 10 5 10 20 5 10 20 40 H x W x D/ Weight 130/32/125 mm/ 0.6 kg 130/40/125 mm/ 0.8 kg 130/50/125 mm/ 0.9 kg 130/60/125 mm/ 1 kg 130/90/150 mm/ 2.0 kg 130/140/150 mm/ 3.4 kg 130/32/125 mm/ 0.6 kg 130/32/125 mm/ 0.6 kg 130/40/125 mm/ 0.8 kg 130/60/125 mm/ 1 kg 130/90/150 mm/ 2.0 kg 130/140/150 mm/ 3.4 kg 1478100000 1478110000 1478120000 1478130000 1478140000 1478150000 1478210000 1478220000 1478230000 1478240000 1478250000 1478270000 130/40/125 mm/ 0.65 kg 130/60/125 mm/ 1.3 kg 130/70/150 mm/ 1.3 kg 130/140/150 mm/ 3.1 kg 1478170000 1478180000 1478190000 1478200000 130/34/150 mm/ 0.3 kg 130/60/150 mm/ 0.6 kg 1222210000 1222220000 11 DC-UPS uninterruptible power supply DC-UPS uninterruptible power supply Safe energy in automation Can be used around the world International approvals (cURus, cULus) and TÜV certification facilitate the use of these products around the world, and in different applications. Space saving The ability to mount the UPS components side-by-side in only 66 mm width saves space in the electronics cabinet. Quick error analysis The charging level indicator and the status and error indicators facilitate rapid error analysis. {\ Long battery service life The temperature-compensated characteristic charge curve ensures the best charge for the battery. This maintains the battery‘s long service life. Flexible application Multiple operation modes optimise the use of battery power and facilitate its flexible application. Time saving The three additional active 24 V DC transistor outputs simplify cabling and save time. Create your own, individual power supply solution Buffers short duration You can reliably bridge short power interruptions of several 100 ms with the maintenance-free buffer module. Versatile battery modules of 1.3 to 17 Ah The battery modules are equipped with maintenance-free AGM VRLA batteries. An integrated temperature sensor ensures the constant, accurate charging of the battery. The PROmax power supply units with diverse add-on modules meet nearly every requirement for durable power supplies. 12 WAUS Power Supplies Core Assortment Catalogue 2015 Australia & New Zealand DC-UPS uninterruptible power supply Uninterruptible power supplies DC-UPS 10/20A or 40A Backup power supplies •• Hold up time of 40A for 30mins or 1A for 30 hours •• Extended battery life with temperature controlled charging •• 1 digital input for Interlock •• 3 relay outputs +3 digital—Fault, Buffering, Charging •• LED indication of status •• Hold up times from 0.5 to 45 mins - ∞ •• -25 to +70°C operation •• 1.3, 3.4, 7.2, 12, and 17Ah Battery modules •• NEW Battery test button \ Technical data Indication Electrical safety (applied standards) Status relay ( max.load 30 V AC/DC 0.1 A) Fault (alarm), battery operation (buff.), charging (charg.) Transistor outputs (24 to 27 V DC max. load 150 mA) Fault (alarm), battery operation (buff.), charging (charg.) LED status indicator Three-colour LED: battery capacities > 85 % green, > 40 % yellow, > 20 % red, < 20 % red (flashing) Green/yellow LED: normal / buffering Yellow/red LED: temperature alarm / alarm Yellow/red LED: switch-off / battery fault General technical data Ambient temperature (operational) –25 °C…+70 °C Storage temperature Max. perm. air humidity Protection degree Class of protection Pollution severity level Overvoltage category –40 °C…+85 °C 5…95 % IP 20 3 2 III Insulation voltage input/output to housing/ ground 1300 V DC 1 min (typetest) MTBF > 500,000 hours acc. to IEC 1709 Protection against reverse voltages from the load 32…34 V DC Parallel connection option Housing version Yes, only with diode module for redundancy Metal, corrosion resistant Mounting position, installation notice Horizontal on mounting rail TS 35, 50 mm above and below Space for free movement of air Overload protection Yes Short-circuit protection Yes EMC / shock / vibration Interference emission Interference immunity tests Acc. to EN55022 Class B Acc.to EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (fields), EN61000-4-4 (burst), EN61000-4-5 (surge), EN610004-6 (conducted), EN61000-4-11 (dips) Resistance against vibration and shock Acc.to IEC60954 Vibration: 2.3 g, Acc.to IEC60068-2-31 shock: 30 g in all directions Acc. to EN60204 Safety transformers for switch-mode power supplies Acc. to EN61558-2-17 Machinery with electronic equipment Acc. to EN50178 / VDE0160 Extra-low voltage protection SELV acc. to EN60950, PLEV acc. to EN60204 Battery supply time UPS control unit Ordering Data - UPS Type CP DC UPS CP DC UPS *N. = Nominal N. Voltage N. Current 24V 20A/10A 24V 40A H x W x D/ Weight 130/66/150 mm/ 1 kg 130/66/150 mm/ 1 kg Buffer Time 1.3Ah 3.4Ah 7.2Ah 12Ah 17Ah 10A 20A 40A 11.3min 5min - 11.3min 5min - 26.5min 11.5min 5min 51min 22.7min 9min 81min 34min 13.5min MAX O/P current 15A 25A 50A 50A 50A * Table shows approximate time (when fully charged) based on current. If unsure select 1 battery size higher. Type CP A BATTERY CP A BATTERY CP A BATTERY CP A BATTERY CP A BATTERY *N. = Nominal N. Voltage 24V DC 24V DC 24V DC 24V DC 24V DC 1370050010 1370040010 Battery modules Ordering Data - Batteries Battery modules data details Battery Size Electrical equipment of machines N. Current 1.3 Ah 3.4 Ah 7.2 Ah 12 Ah 17 Ah H x W x D/ Weight 148/52/124 mm/ 1.5 kg 144/108/137 mm/ 3.6 kg 155/162/134 mm/ 5.9 kg 155/229/134 mm/ 9.2 kg 178/242/160 mm/ 13.3 kg 1406930000 1251070000 1251080000 1251090000 1251110000 13 Uninterruptible power supply - DC Buffer modules DC Buffer Module Your 24 V DC supply saviour The perfect backup solution Buffer units use capacitor base storage instead of batteries to over-ride short dips in the 24V DC power supply to provide a smooth and continuous supply for 260ms at 20A, or 1A for 6 seconds. Buffer units are simply installed in series between the 24V DC supply and the load and are maintenance free with a MTBF greater than 57 years, providing 2 outputs for feedback of ready and fault plus LED indication. •• Maintenance Free •• Parallel units to increase time •• Output notification for OK and Fail •• LED status indication •• Operating temperature range: -25 ˚C...70 ˚C Technical data Input DC Buffer Module Ordering Data Dimensions 150/66/130 1.15kg Input voltage 24V DC (22.5...30V DC) Input current Max. input current 0...22A 22A Weight Input protection Transient surge protection, 35V DC suppressor diode Type Output 24V DC Output voltage adjustable range Output current 22.5...30 V DC 20A, Max.22A Parallel connection option Yes, to increase buffer time, without diode module Series connection option Overload protection (Discharging process) Over voltage protection (Discharging process) Fail - Relay NO ≥ 22A 31...34 V 30V AC/DC 2A Ready - Active Digital 24V DC, 300mA voltage Indication Ready General data Length x Width x Height mm Ordering data Output voltage CP DC BUFFER 24V 20A 1251220000 non-safe load Green LED 95% Memory medium Charging time Buffering time Internal, capacitor 25S 200˜ 300ms at 20A 6S at 1A MTBF >100.000h acc. MIL-HDBK 217(Bellcore); >500.000h acc. IEC 1709(SN29500) Ambinent temperature - 25 ˚C...+70 ˚C (mounted without clearance between units) Storage temperature -40...+85 ˚C Clamping mm2 (norminal/min./max.) Order No. Block diagram Efficiency Screw connection data \ % Input 10/0.3/16 Output 10/0.3/16 Safe Load Signal Line Buffer time 4/0.13/6 7 [S] Buffering Time 6 5 4 3 2 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 [A] 24 V DC 14 WAUS Power Supplies Core Assortment Catalogue 2015 Australia & New Zealand connectPower DC/DC converter DC/DC converter Stablise and isolate 24V DC supply Isolate and regulate your DC supply The 10A, 24V/24V DC-DC converter is designed to isolate and regulate 24V DC supplies distributed from other sources. With a voltage range of 18-31V DC input/ 22.5...29.5V output, can be used in Ship building, Process or Automation applications. The DC/DC converter can eliminate ground loops on long 24V DC runs, be used in floating ground systems, or regulate supply from a 24V DC battery system. •• Wide ranging input •• Adjustable output voltage •• Integrated fault alarm •• Wide operating temperature General technical specifications Ordering Data Output characteristic curve / current limit IU / > 120 % IR Earth discharge current Ambient temp. Operating / storage temp. Max. permitted humidity (operational) Protection degree Class of protection Contamination degree < 0.005 mA –25 °C … +70 °C / –40 °C … +85 °C 5 %…95 % RH IP 20 III 2 Insulation voltage 2.5 kV AC 1 min. / 1.5 kV AC 1 min. / 0.5 kV AC 1 min. Overvoltage category III MTBF > 500,000 hrs. according to IEC 1709 (SN29500) Protection against load reverse voltages Parallel capability (without diode module) Mountable side-by-side without gaps Housing version, metal Signal operations Mounting position, installation notice 33…34 V DC Yes, max. 5 Yes Resistant to corrosion LED green / red Horizontal on TS 35 DIN rail, above and below 50 mm Clearance for air circulation, suitable for aligning without clearance gap For installation in rotating systems Yes Metal clip-on foot EMC / shock / vibration Noise emission according to EN55022 Interference immunity tests, according to Limiting of mains voltage harmonic currents Resistance against vibration and shock Electrical safety (applied standards) 150 / 60 / 130 mm 1250 g Length x Width x Height mm Weight Ordering data CP DCDC 250W 24V 10A 1313320010 Type Order No. Accessories Type CP A WALL ADAPTER 45MM SDIS 0.5X3.0X100 SDIS 1.0X5.5X125 Order No. 1461850000 9008380000 9008410000 Description Wall mount bracket Small screwdriver Large screwdriver Derating curves Connection diagram PE N + L Load Temperature derating 130 – 120 Charger 110 100 90 80 70 60 Class B EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields), EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted), EN61000-4-11 (Dips) According to EN 61000-3-2 DC/DC converter Dimensions Pout [% Pn] Technical data \u % 20 30 40 50 60 70 80 Battery bank Ambient temperature [°C] – + According to EN50178, shock: 5 g in all directions Electrical equipment of machines According to EN60204 Safety transformers for switched-mode power units According to EN61558-2-17 Machinery with electronic equipment According to EN50178 / VDE0160 Safety extra-low voltage SELV according to EN60950, PLEV according to EN60204 Protective separation Protection against electrical shock VDE0100-410 According to DIN57100-410 Protection against dangerous shock currents According to VDE0106-101 15 connectPower PRO-H PRO-H power supply Industrial power supplies for extreme requirements Shock & vibration proof Designed for use in areas of high shock and vibration. Status Alarms Green LED OK Red LED OFF Remote alarms 16 Reliable Equiped for long reliable service life. High Mean Time Between Failures (MTBF) up to 1.8 Million hours. Robust Wide temperature range from –25 °C to +70 °C. WAUS Power Supplies Core Assortment Catalogue 2015 Australia & New Zealand connectPower PRO-H PRO-H power supply High performance power supplies For extreme requirements The PRO-H is a new generation of high performance DIN-rail mounted single and two phase wide voltage power supplies designed to provide extended service life in Process and Machinery applications where reliability is paramount. The SNT2 models provide continuous output with supply inputs from 100-500VAC, providing a truly universal supply for any electrical power system. The PRO-H Redundancy modules are active modules that communicate with PRO-H power supplies to provide 100% current sharing ensuring your redundancy provides the best performance. % { \ | CB Scheme •• MTBF >100 years •• Output OK signalling •• Wide operating voltage •• Active redundancy modules •• Remote input for output on/off General technical data Derating curves Ambient temp. operating / storage temp. Max. perm. air humidity (operation) Degree of protection / Class of protection Insulation voltage input/output -25…+70 °C / -25 °C…+85 °C 95 % RH IP 20 / I, with PE connection 4 kV I/O, 2 kV I/earth, 0.5 kV O/earth MTBF according to IEC 61709 CP T … 70/90 W > 1.8 Mio. h CP T … 140 W > 1.2 Mio. h CP T … 180/360/600 W > 0.9 Mio. h Protection against reverse voltages from the load 16 V DC / 35 V DC / 63 V DC Parallel connection option Housing version Overload protection Short circuit protection Yes, without diode module Metal, corrosion resistant Thermal protection, automatic restart Unlimited, automatic restart Mounting position, installation notice Horizontal on TS 35 mounting rail, with 80 mm space at top and bottom. Side by side mounting with 50 mm clearance. Stripping length (rated connection) 7 mm Signal indication Power Good Signal Max. limiting average on state current [A] CP T SNT... 100 90 Output Power [% Pmax] Technical data 600 W 80 70 90 W 180 W 360 W 60 50 40 -25 40 50 70 W 140 W 60 Potential free, floating signal contact NO contact: 30 V DC / 1.0 A max. for 12/24 V DC modules NO contact: 48 V DC/ 0.5 A max. for 36/48 V DC modules Active output signal 70 W: 11 V DC ± 1 V DC / 20 mA max. 140 W: 11 V DC ± 1 V DC / 40 mA max. 90 W: 22 V DC ± 2 V DC / 10 mA max. 180/360/600 W 24 V DC, 22 V DC± 2 V DC / 20 mA max. 180/360/600 W 48 V DC, 44 V DC± 4 V DC / 15 mA max. 50°C 5.7 9.5 3.1 6.3 12.5 22.5 15.0 1.6 3.3 6.3 11.3 6.3 12.5 22.5 60°C 5.4 7.0 2.5 5.0 10.0 20.0 13.3 1.3 2.5 5.0 10.0 5.0 10.0 20.0 70°C 4.5 3.7 1.7 3.3 6.7 13.3 9.0 0.8 1.7 3.3 7.5 3.3 6.7 13.3 Ordering Data Type CP T SNT Trigger point: 12 V Version 9…11 V DC Trigger point: 24 V Version 18...22 V DC Trigger point: 48 V Version 36...44 V DC 70 Temperature [°C] Typ\Temp. 40°C 1 ph 12V/6A 6.0 1 ph 12V/12A 12.0 1 ph 24V/3.8A 3.8 1 ph 24V/7.5A 7.5 1 ph 24V/15A 15.0 1 ph 24V/25A 25.0 1 ph 36V/16.5A 16.5 1 ph 48V/2A 2.0 1 ph 48V/4A 4.0 1 ph 48V/7.5A 7.5 1 ph 48V/12.5A 12.5 1-2 ph 24V/7.5A 7.5 1-2 ph 24V/15A 15.0 1-2 ph 24V/25A 25.0 Output voltage Output current CP T SNT 70W 12V 6A 12V DC 6.5 A CP T SNT 140W 12V 12A CP T SNT 90W 24V 3.8A CP T SNT 180W 24V 7.5A CP T SNT 360W 24V 15A CP T SNT 600W 24V 25A CP T SNT 180W 48V 4A CP T SNT 360W 48V 7.5A 12V DC 24V DC 24V DC 24V DC 24V DC 48V DC 48V DC 13.0 A 3.75 A 7.5 A 15 A 25 A 4A 7.5 A CP T SNT 600W 48V 12.5A 48V DC 12.5 A CP T SNT2 180 W 24 V 7.5 A 24V DC 7.5 A CP T SNT2 360 W 24 V 15 A 24V DC 15 A CP T SNT2 600 W 24 V 25 A 24V DC 25 A CP T RM 10 24V DC 15A @ 24V DC @ 40°C CP T RM 20 24V DC 25A @ 24V DC @ 40°C Type CP T SNT2 PRO-H diode modules Order No. 1105430000 1105440000 1105790000 1105810000 1105820000 1105840000 1105850000 1105860000 1105870000 1194480000 1194490000 1194310000 1105880000 1105890000 17 PRO-E power supply NEW PRO-E power supply Plate-mounted single-phase power supply for autonomous applications Safe operation Overload protection, short-circuit protection, surge protection and reverse polarity protection guarantee stable operation. Has a wide range of uses Wide range input voltage of 85–264 V AC and 110–370 V DC. 18 Robust Wide operating temperature range from – 25°C to 70°C (derating from 50°C, 70 % at 70°C). Can be used around the world All-purpose usage due to worldwide approvals CE, UL, TÜV, CCC. WAUS Power Supplies Core Assortment Catalogue 2015 Australia & New Zealand PRO-E power supply PRO-E power supply Plate-mounted power supplies For industrial automation Our new plate-mounted PRO-E power supplies offer an excellent price/performance ratio and are designed for all-purpose use. Thanks to the wide variety of models with output voltages of 5 V, 12 V, 24 V and 48 V, as well as extensive international approvals, it is suitable for use in many applications. The performance bandwidth ranges from 25 W up to 350 W. Individual adaptability makes PRO-E the right choice for your power supply % { \ | CB •• Stable DC output voltage •• Wide AC and DC input voltage range •• Adjustable output voltage •• Wide operating temperature range: -25 ˚C...70 ˚C •• Worldwide approvals: CE, UL, TÜV, CCC, CB •• Robust and stable housing Scheme Dimensions Technical data Input Input voltage 85–264 VAC, 110–370 VDC Input frequency 47–63 Hz Output Output voltage 5 VDC Output voltage adjustment ±10 % of the rated output voltage (with potentiometer) 12 VDC 24 VDC Rated output power 25W, 50W, 75W, 100W, 150W, 250W, 350W Overload protection 120~150 % Iconst. of the rated output current, automatic restart Over voltage protection, YES 5.6~6.8 V 13.5~16.2V 28~32 V Hold-up time ≥20 ms Control at 10…100 % load (load regulation) 0.5 % - 350W ≤ 2% Parallel connection option Isolation to enclosure 48 VDC 55~62 V 0.5 kVAC Isolation input – earth 1.5 kVAC Isolation input – output CP E SNT 25W 5V 5A 3 kVAC General data Operating temperature –20 °C to 70 °C (>50 °C derating, see diagram); 70% @ 70 °C Storage temperature Humidity during storage Efficiency, 76 ... 87 % Status indicator Standards –20 °C to +85 °C 5~95 % 77 % 79 % green LED EN 60950 Electromagnetic compatibility EN 55011, EN 55022, EN 55024, EN 61000-6-2, 3 Fixing Weight wall mounting, screwable 0.24 kg - 1025 kg Approvals and marks CE, cURus, TÜV, CCC, CB Screw connection Wire cross-section mm² 0.34~4 84 % 83 % Dimensions H x W x D mm 28 x 51 x 91 mm 35 x 100 x 105 mm 40 x 98.5 x 135 mm 40 x 97.5 x 164 mm 40 x 99 x 205 mm 230 x 115 x 49.5 mm 230 x 115 x 49.5 mm Ordering Data Type with diode module Isolation output – earth Type CP E SNT 25W CP E SNT 50W CP E SNT 75W CP E SNT 100W CP E SNT 150W CP E SNT 250W CP E SNT 350W Output voltage Output current Output power 5V 5A 25 W CP E SNT 25W 12V 2.1A CP E SNT 25W 24V 1.1A CP E SNT 25W 48V 0.57A CP E SNT 50W 5V 10A CP E SNT 50W 12V 4.2A CP E SNT 50W 24V 2.2A CP E SNT 50W 48V 1.1A CP E SNT 75W 5V 12A CP E SNT 75W 12V 6A CP E SNT 75W 24V 3.2A CP E SNT 75W 48V 1.6A CP E SNT 100W 5V 16A CP E SNT 100W 12V 8.5A CP E SNT 100W 24V 4.5A CP E SNT 100W 48V 2.3A CP E SNT 150W 12V 12.5A CP E SNT 150W 24V 6.5A CP E SNT 150W 48V 3.3A CP E SNT 250W 12V 21A CP E SNT 250W 24V 10.5A CP E SNT 250W 48V 5.2A CP E SNT 350W 24V 14.6A 12V 24V 48V 5V 12V 24V 48V 5V 12V 24V 48V 5V 12V 24V 48V 12V 24V 48V 12V 24V 48V 24V 2.1A 1.1A 0.57A 10A 4.2A 2.2A 1.1A 12A 6A 3.2A 1.6A 16A 8.5A 4.5A 2.3A 12.5A 6.5A 3.3A 21A 10.5A 5.2A 14.6A 25 W 25 W 25 W 50W 50W 50W 50W 75W 75W 75W 75W 100W 100W 100W 100W 150W 150W 150W 250W 250W 250W 350W CP E SNT 350W 48V 7.3A 48V 7.3A 350W Order No. 1202640000 1202630000 1202620000 1202610000 1202590000 1202580000 1202450000 1202460000 1202470000 1202480000 1202490000 1202510000 1165820000 1165830000 1165840000 1165850000 1165870000 1165880000 1165890000 1202520000 1202530000 1202540000 1202550000 1202560000 19 connectPower INSTAPOWER INSTAPOWER Single phase 25-48W Adjustable output versatility The INSTAPOWER single phase 25-48W power supplies provide the answer to a wide range of power supply needs. Just four different modules provide for all output voltages from 4 to 55V DC. An easily accessible trimpot is provided via an access port to enable wide adjustment to meet your requirements. Fully protected against overload, INSTAPOWER 48W provides up to 50% over current to start your load. •• Wide range of adjustment & universal AC/DC inputs •• Suitable for use as a DC/DC Converter •• Ultra-compact only 70mm wide •• Mounts on standard TS35 DIN rail % \ Technical data Type CP SNT 25W 5V 5A 4-8V DC Output voltage Output current Input voltage CP SNT 48W 12V 4A CP SNT 48W 24V 2A 9-15V DC 15-28V DC 4A 2A 85-264V AC / 110-370V DC 85-264V AC / 110-370V DC CP SNT 48W 48V 1A 46-55V DC 1A 85-264V AC / 110-370V DC 5A 85-264V AC / 110-370V DC Order No. 8754960000 8754970000 8739140000 8879230000 INSTAPOWER Single phase 24W For driving inductive loads Devices such as relays, contactors, solenoids and motors all require an initial starting current many times their normal level. The compact INSTAPOWER range has the capacity to supply the initial inrush current to start inductive loads and can actually provide 3 times their rated output for a short duration. •• Thermal overload protection & automatic restart •• High Efficiency & universal inputs •• Compact design only 52mm wide •• Mounts on standard TS35 DIN rail •• Suitable for use as a DC/DC converter % \ Technical data Type 20 CP SNT 24W 5V 2A 5V DC Output voltage Output current Input voltage CP SNT 24W 12V 1.5A CP SNT 24W 15V 1.5A CP SNT 24W 24V 1A 12V DC 15V DC 24V DC 1.5 A 1.5 A 1A 85-265V AC / 120-300V DC 85-265V AC / 120-300V DC 85-265V AC / 120-300V DC CP SNT 24W 28V 1A 28V DC 1A 85-265V AC / 120-300V DC 2A 85-265V AC / 120-300V DC Order No. 9928890005 9928890012 9928890015 9928890024 9928890028 WAUS Power Supplies Core Assortment Catalogue 2015 Australia & New Zealand Fuse protection WAVEGUARD 24V DC Electronic fuse protection •• Front panel on/off switch •• Local or remote reset •• LED status indication Technical data Type Unom [V] IOUT [A] WGS 24 V dc 1.6 A 24 1.6 WGS 24 V dc 3.15 A WGS 24 V dc 6.3 A WGS 24 V dc 8.0 A 24 24 24 3.15 6.3 8.0 WGS 24 V dc 0.5–5 A 24 0.5–5 adjustable Order No. 8618890000 8618910000 8618930000 8618940000 8710270000 \ % Fuse Terminals Overload and short-circuit protection ZSI 28 V DC WSI 6 Metric fuses WSI 6 LD Metric fuses / bipolar LED ETA 1170 Ordering data Type ZSI 2x6/4x2.5 FC Qty. 10 Order No. 1058520000 *Note: Suitable for auto fuse or circuit breaker Accessories Circuit breaker 1170 3 4 5 6 7.5 8 10 15 20 25 Colour violet pink orange green brown yellow red blue yellow white Ordering data Type WSI 6 Qty. 50 Order No. 1011000000 *Note: Suitable for auto fuse or circuit breaker Order No. 1278730000 1278740000 1278750000 1278760000 1278770000 1278780000 1278790000 1278810000 1278820000 1278830000 Accessories for WSI 6 / LD Screwable cross-connection 2-pole 3-pole 4-pole 10-pole G-fuse cartridge, 5 x 20 mm 0.10 A fast 0.20 A fast 0.25 A fast 0.50 A fast Type Current Order No. QL 2 SAK6N QL 3 SAK6N QL 4 SAK6N QL 10 SAK6N Type 32 A 57 A 57 A 32 A Voltage 0194300000 0194400000 0194500000 0338300000 Order No. G 20/0.10 A/F G 20/0.20 A/F G 20/0.25A/F G 20/0.50A/F 250 V 250 V 250 V 250 V 0430300000 0430400000 0430500000 0430600000 Ordering data Type Description WSI 6/LD 10-36V DC/AC 10-36V AC/DC WSI 6/LD 30-70V DC/AC 30-70V AC/DC WSI 6/LD 60-150V DC/AC 60-150V AC/DC WSI 6/LD 250AC 140-250V AC/DC *Note: Suitable for auto fuse or circuit breaker Accessories for WSI 6 / LD G-fuse cartridge, 5 x 20 mm 0.63 A fast 1.00 A fast 1.60 A fast 2.00 A fast 2.50 A fast 3.15 A fast 4.00 A fast 5.00 A fast 6.30 A fast Order No. 1011300000 1012200000 1012300000 1012400000 Type Voltage Order No. G 20/0.63 A/F G 20/1.00A/F G 20/1.60 A/F G 20/2.00A/F G 20/2.50 A/F G 20/3.15 A/F G 20/4.00 A/F G 20/5.00 A/F G 20/6.30 A/F 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 250 V 0439000000 0430700000 0430800000 0430900000 0431000000 0431100000 0431200000 0431300000 0431400000 21 Technical overview Application specific requirements Weidmüller – power supply solutions for all applications Parallel operation + DC-DC conversion Load DC UPS – PE N + L Load + 24 V DC 24 V DC +– – – Charger Battery bank – + L N PE Alarm Status Increasing the output power Galvanic isolation and stabilisation Uninterruptible power supply The direct parallel circuit consisting of several power supplies enables customised adaptation of the output power. This must not be confused with redundant switching, when the stabilised load current is to be shared equally. DC/DC converters galvanically isolate the input from the output voltage and prepare them: Mains interruptions and brown-outs are a frequent cause of system failures. Battery-supported or capacitor based uninterruptible power supply units (UPS) units cover these types of mains network faults and thereby increase system availability. •• PROeco, PROmax and PRO-H power supply units: up to five devices can be connected in parallel. •• Also featuring our INSTAPOWER power supplies: up to three devices can be directly switched in parallel. •• Indication of the failure of individual devices can be achieved using optional diode modules. •• To compensate for voltage losses which occur due to the higher cable resistance, •• To avoid ground loops which can occur in plants which are spread over a large area. •• A potential-free alarm relay and a transistor output give you full status monitoring. •• The DC/DC-Converter is a protection class III device, thus you can use them in floating earth systems such as might be found when operating back-up batteries. Useful information To ensure the most even distribution of the load within the parallel connected power supply units, the voltage difference must not be more than ±50 mV. This balance is achieved when the plus wire is connected. Symmetrical wiring also helps to distribute the current uniformly. 22 Charging Status Buffering Status Antenna Solar Cell Antenna •• Different status relays permit status monitoring. •• The UPS control unit monitors the input voltage and, in the event of a fault, switches immediately to battery operation. •• When the power is restored, the input voltage is again switched over to the load and the battery is recharged. •• An integrated deep-discharge protection system and an optimised charge curve ensure that the battery has a long service life. 24VDC I/O Devices and Sensors I/O 24VDC 24VDC Radio Transmitter 24V (powered) SCADA System or Other Type of Control System 24VDC WAUS Power Supplies Core Assortment Catalogue 2015 Australia & New Zealand Technical overview CAP module Redundancy + Load Electronic fusing + – Load – Load 1 + Load 2 Load 3 Load 4 – Alarm A L1 L2 L3 PE Status relay 24 V + Load – A B B Status relay 24 V L1 L2 L3 PE Reset L N PE Power reserve for peak currents Redundant power supply units Selective load protection For selective triggering of circuit breakers or for short-term additional power reserves, a capacitor module can be integrated into the 24 V circuit. The availability of the power supply units is increased by the use of redundant circuits. Here, each individual power supply unit can cope with the total load required in the event of a failure by itself. The breakdown of the whole secondary load into individual load circuits which have quick-operating safety elements in case of a fault is known as selective load protection. Electronic fuses are ideal to meet the special requirements found in selective load protection. •• The integrated alarm relay monitors the input voltage, thereby monitoring the status of the 24 V DC power supply. •• Sufficient power for the pulse triggering of circuit breakers (MCBs) •• To further increase the power reserves, multiple capacitor modules can be connected in parallel. Ordering Data Type CP M CAP U [V] 18-30 I [A] / 1 [ms] 40 Order No. 7760052061 •• In the case of redundancy switching, the diode module‘s output current must not exceed that of either switched-mode power supply units. •• Diode modules are also used for a secure parallel circuit of switched-mode power supply units. •• Full status monitoring thanks to integral alarm monitoring the voltage of both inputs. Useful information TIP The capacitor module can be used independently of the output power from the power supply modules. When triggering circuit breakers, the line impedance must be observed. You will find the relevant values for circuit breakers here: www.weidmueller.com/MCB An example of redundant power supply units •• The tripping characteristic curve of the electronic fuse is, on the one hand, fast enough to switch off the faulty circuit quickly; and on the other, tolerant enough to deal with a motor start-up or capacitive loads. •• A switch to turn the output on or off means that it is simpler to diagnose errors and to commission. •• The fuse triggering is signalled via a potential-free alarm relay •• A reset input allows the fuse to be switched on again remotely. for an output current of 20A: 2 x PRO-M, 20A + 1x CP M DM20 for 40A output load: 2 x PRO-M, 40A + 2x CP M DM40 23 Technical overview Active redundancy 24 V PRO-M 24 V – 100% Load 50% Load Pout [% PN] 50% Load 24 V PRO-M 24 V M M 130 120 Additional Power 110 Reserve up to 45°C 100 90 80 70 60 t 3 ms Temperature derating Temperature derating 130 Pout [% PN] + L N PE 20 30 40 120 Additional Power 110 Reserve up to 45°C 100 90 Δ –2.5 % U [V] U out U out Δ –2.5 % 80 Power Power 70 Reserve Reserve 60 20 50 30 60 40 70 50 80 60 Ambient temperature [°C] Ambient temperature [°C] 70 80 IN I Reserve IN I [A] I Reserve t PRO-M Output Power Derating Curve U/I output characteristic with power reserve Active load distribution Operating temperature, power reserve and derating Short-circuit and overload Active load distribution (active current sharing) ensures that a load current is evenly shared over two power supplies. The availability of the total power supply is increased considerably, as each power supply is always operated with just half of the nominal load at most. Power supply units for industrial use offer extended operating temperature ranges (–25 to +70 °C). Up to the “derating” operating point, they have power reserves, above this point they can only be operated at reduced load. The PROmax power supply units follow the IU output characteristic curve in the event of a short-circuit/overload and are therefore permanently short-circuit proof. Useful information Only use devices of the same type at all times. Active load distribution is guaranteed by means of the redundancy modules CP T RM 10 and CP T RM 20. •• Up to 45 °C, the device can be operated continuously with maximum of 120 % of rated current. •• Up to 60 °C is 100% of rated current available. •• Compared to Hicc-up or foldback characteristic curves, operation with almost any capacitive loads is possible. •• PROmax power supply units deliver a constant 120 to 150 % of the nominal current in short-circuit operation with a simultaneously reduced voltage. •• When the short-circuit or the overload is removed, there is a prompt return to normal operation. Inrush current limit Inrush current limiters improve the dimensioning of the mains fuses •• Power supply units from the lower power classes mainly have a passive inrush current limiter, e.g. PRO-M 3 A and 5 A models. •• Power supply units with larger power classes have an active inrush current limiter, e.g. all 1-phase PRO-M modules above 10 A. 24 U [V] I Imax Imax Without active current limiting With active current limiting t WAUS Power Supplies Core Assortment Catalogue 2015 Australia & New Zealand I Power Supply Selection Considerations Power Supply Selection Considerations Output Voltage All Weidmüller Switchmode Power Supplies have a regulated output voltage, that is the output voltage remains constant irrespective of input voltage or load current, provided the supply voltage is within the specified range. Most models can be powered from DC as well as AC Environmental Environmental issues to consider are the ambient temperature where the power supply is expected to operate. Note the derating for high ambient temperature use. Vibration in the area of use must also be considered. Power Boost All Weidmüller Switchmode Power Supplies have start up boost of up to 400%. This allows for non resistive loads to be started. Inductive loads, i.e. solenoid valves and motors, have a starting current as high as six times full load current, while capacitive loads, i.e. some electronic devices and PLC’s with input filtering capacitors have a start up current of up to twelve times. Switchmode power supplies have a built in protection circuit which turns the output off if a sudden load is introduced which exceeds the rated load of the power supply. Method of operation Primary switchmode power supplies are distinguished by a high degree of efficiency and also by their compact dimensions and moderate generation of heat. The mains voltage is rectified directly. The rectified voltage is then chopped with a higher frequency than that of the mains frequency. A transformer (which can be quite small due to the high switching frequency) converts the voltage with the switching frequency to the required value. Short Ciruit Protection Short circuit protection is also built in so that if there is a short circuit in the load circuit the power supply will shutdown until the short circuit is removed, and will auto start. Mounting Mounting types available are “DIN” rail mounting or chassis / panel mounting. Wall mount options are also available. Redundancy For redundant operation where two identical power supplies are connected in parallel, for reliability and safety reasons the use of diode auctioneering modules is necessary. In this configuration there is no possibility of a back feed from one power supply to the other and supply failure alarms can be operated. Load Sharing When two or more power supplies are to be connected in parallel for power sharing the output voltage of the power supplies must be adjusted to be within 50mV of each other. To achieve this the voltmeter being used must be accurate and all test leads must be securely connected when making the adjustment, not just held or pushed onto the terminals. The method of wiring must also be done in the correct configuration so as to avoid different wire lengths when bridging the power supplies. If possible the use of a single higher output power supply is a better option than parallel connect smaller power supplies. It is often difficult to get more than two parallel connected power supplies to current share. The voltage is now rectified and smoothed by a filter. This regulator control itself is carried out by means of pulse-width modulation. The on and off times of the chopper transformers are regulated to ensure that the output voltage remains stable. Overload Protection Overload thermal protection is built in to protect the power supply if the load applied is in excess of the rated current, for a period of time. This will shutdown the output until the power supply cools down, and will need to be reset by disconnecting and reconnecting the input supply. 25 Glossary Glossary AGM Stands for Absorbed Glass Mat. AGM batteries belong to the VRLA battery family which has the electrolyte absorbed in a fiberglass mat separator. A gel cell has the electrolyte mixed with silica dust to form an immobilized gel. Very thin glass fibres are woven into a mat to increase surface area enough to hold sufficient electrolyte on the cells for their lifetime. Float Charge Float Charge is the constant voltage that is applied continuously to a voltaic cell/battery under operation. The voltage could be held constant for the entire duration of the battery cell‘s operation held for a particular phase of charging by the charger. The appropriate float voltage varies significantly with the chemistry and construction of the battery, and ambient temperature. With the appropriate voltage for the battery type and with proper temperature compensation, a float charger may be kept connected indefinitely without damaging the battery. Hold-up time (mains-failure bridging time) The hold-up time (also known as the mains-failure bridging time) is the interval from the start of the mains outage to the point in time when the output voltage can no longer be maintained at its original level. The hold-up time indicates how long a mains outage may last before it influences the output voltage. For DC power supplies, EN 61204 requires a bridging time of at least 20 ms. U UA hold-up time Power failure (cutoff) t Inrush current The inrush current refers to the peak current that occurs when turning on a consumer load. Switched-mode power supplies have storage capacitors in the input which can cause significant current peaks while the mains power is being switched on. A variety of circuitry solutions can be used to attenuate these current peaks. In the simplest solution, an inrush limiter is used. Active switching can be used in other cases. The peak current specification indicates which upstream fuse should be used in the circuit. If a fuse is selected which is too sensitive, it can trigger when the mains power is switched on. Interlock The bridge link across the interlock terminals must be removed to avoid unintended battery operation during installation and initial test. 26 IU characteristic curve The IU characteristic curve is a special output characteristic curve that protects power supply units from overloads and short circuits. It offers the best performance with regards to overload and short circuit capabilities. A current limit is activated at a specific current level (for example, 110 or 120% on the nominal rating). As the load continues to increase, the output voltage is reduced according to the current limit curve until it reaches a level approaching zero volts. Thus a pulsating mode of operations is avoided for short-term overloads. Large capacitive loads or motors are brought back up along the slope of the current-limit characteristic curve. After a short circuit or overload is fixed, the IU characteristic curve offers the advantage of immediately returning to the normal voltage control mechanism. The full output voltage is then immediately available. The IU characteristic curve is becoming the established standard for modern power supplies. Additional variants are available which pertain to the peak current capacity and the slope of the current-limit characteristic curve. U UA INominal I Limit I UPS Uninterruptable Power Supply is a 3 stage device. Input stage, charger for maintaining batteries, and output stage. If the input power is reduced or drops, energy is derived from the charged batteries to deliver power to the output instantaneously. VRLA Batteries Stands for Valve Regulated Lead-Acid Battery. More commonly known as a sealed lead-acid battery. These batteries have a pressure relief valve which will activate when the battery is recharged at high voltage. VRLA batteries offer several advantages compared with flooded lead–acid cells. The battery can be mounted in any position, since the valves only operate on overpressure faults. Since the battery system is designed to be recombinant and eliminate the emission of gases on overcharge, room ventilation requirements are reduced and no acid fume is emitted during normal operation. The volume of free electrolyte that could be released on damage to the case or venting is very small. There is no need (nor possibility) to check the level of electrolyte or to top up water lost due to electrolysis, reducing inspection and maintenance. WAUS Power Supplies Core Assortment Catalogue 2015 Australia & New Zealand You have equipped your system with an everlasting supply We take care of the rest with links Make your system completely reliable and efficient. Our portfolio helps you do this with coordinated products from the power supply to simple installation in the cabinet. Your application requirements don‘t stop at guaranteeing reliable system availability. The upstream power supply and optimum lightning and surge protection are just as important. Downstream, custom-fit potential distributors and reliable signal and data transmission are essential if your system is to run smoothly. Our extensive portfolio caters to every need including simple installation thanks to our high-quality tools and marker systems. When it comes to supplying power, we assist you with a range of practical products. We offer you convenient and space-saving cabling options for a huge variety of cross-sections. The products in our VARITECTOR family reliably protect your power distribution and the downstream devices against lightning and surge damages. Our relay modules and solid-state relays for the digital interface layer are characterised by reliability and longevity. They switch and amplify digital signals in your automation and are used for galvanic isolation between 5 V, 12 V, 24 V up to 230 V AC/DC. During planning and installation work, you benefit from different designs and a wide variety of variants. u-remote, the innovative remote I/O solution in an IP 20 package reliably combines sensors and actuators with the control using an extremely wide range of field bus systems. Benefit from the modular and compact design, and shrink the size of your cabinets. Our Industrial Ethernet devices offer an extensive communication infrastructure in your machine network. Let‘s connect. Find out more about the products and services we offer to guarantee a permanent supply for your automation, please see website or Electronics Main Line Australian and New Zealand 2014-2015 We cannot guarantee that there are no mistakes in the publications or software provided by us to the customer for the purpose of making orders. We try our best to quickly correct errors in our printed media. All orders are based on our general terms of delivery, which can be reviewed on the websites of our group companies where you place your order. On demand we can also send the general terms of delivery to you. 27 Weidmüller – Partner in Industrial Connectivity. As experienced experts we support our customers and partners around the world with products, solutions and services in the industrial environment of power, signal and data. We are at home in their industries and markets and know the technological challenges of tomorrow. We are therefore continuously developing innovative, sustainable and useful solutions for their individual needs. Together we set standards in Industrial Connectivity. To find your local Weidmüller Distributor or Partner please visit www.weidmuller.com.au/au/distributors Or contact your preferred supplier below: Weidmüller Pty Ltd (Head Office) 43 Huntingwood Drive, Huntingwood NSW 2148 Phone +61 (0) 2 9671 9999 Fax +61 (0) 2 9671 9900 Email [email protected] www.weidmuller.com.au Order number: WAUS Power Supplies Core Assortment Catalogue 2015 Australia & New Zealand