Download

Switched-mode and uninterruptible power supplies,
and electronic fuses
Catalogue 2015/2016
Let’s connect.
Power supply
Switch-Mode and
Uninterruptible Power Supplies,
Electronic Fuses
Contents
Switch-Mode and Uninterruptible Power Supplies,
Electronic Fuses
Catalogue 4.3
A
Switch-mode power supplies
B
Uninterruptible power supplies (UPS)
C
Fuse protection for 24 V DC circuits
D
Unregulated power supplies
Appendix
Electrical cabinet socket outlet
E
Glossary/Technical appendix
W
Index
2003670000
X
Index Type / Index Order No.
Addresses worldwide
I
Product overview
Power supplies – Overview
II
connectPower 1ph PROeco
connectPower 3ph PROeco
connectPower PROeco diode modules
• Single-phase switched-mode power supply modules
• Slim design
• Large temperature range from –25 °C to 70 °C
• Three-coloured LED indicators for simple error
detection
• Advanced visual warning at 90 % rated output current
• International approvals
• 3-phase switched-mode power supply modules
• Slim design
• Large temperature range from –25 °C to 70 °C
• Three-coloured LED indicators for simple error
detection
• Advanced visual warning at 90 % rated output current
• International approvals
• Diode module for 100 % decoupling of
switched-mode power supply modules
• Optimum doubling of output power
• Redundancy operation
• Up to 40 A output current can be set
• International approvals
connectPower 1ph PROmax
connectPower 3ph PROmax
connectPower PRO-M Extension modules
• Single-phase switched-mode power supply
modules
• Very slim design
• High degree of efficiency
• Power category 70...1,000 W
• Up to five devices can be connected in parallel
without a diode module
• International approvals
• 3-phase switched-mode power supply modules
• Very slim design
• High degree of efficiency
• Power category 120...1,000 W
• Up to five devices can be connected in parallel
without a diode module
• International approvals
• Capacity module for increasing the peak current
• Diode modules for redundant construction
• Relay module for monitoring the output voltage
connectPower PRO-M Application solutions
connectPower 1ph PRO-H
connectPower PRO-H Multi-phase
• Wide-range input
85...264 V AC
80...430 V DC
• Alarm relay
• Metal snap-on foot
• International approvals
• Single-phase switched-mode power supplies
• High MTBF values
• Cl. I Div. 2 + ATEX
• Performance class: 70 to 600 W
• Output: 12, 24, 36 and 48 V DC
• Multi-phase switched-mode power supplies
• 85...132 / 187...550 V AC
• UL approval
• Performance class: 180 to 600 W
2003670000
Product overview
connectPower PRO-H Redundancy modules
connectPower PRO-E
connectPower 1ph INSTAPOWER
• 15 A or 25 A
• 100 % load sharing
• Remote On/Off
• International approvals
• Cl. I Div. 2 + ATEX
• Wall mounting
• Flat design
• Metal housing
• Performance classes from 25 W to 350 W
• Universal input and output voltages
• Single-phase switched-mode power supply
modules for the distribution board
• Compact form
• Power category 24 and 48 W
• Universal input and output voltage 5…48 V
• International approvals
connectPower 1ph WAVEPOWER
connectPower DC/DC converters
connectPower UPS control unit
• Single-phase switched-mode power supply unit
• Slim design 22.5 mm
• Power category 12 W
• International approvals
• Compact form
• Metal housing
• Universal input and output voltage of 5 V to 48 V
• International approvals
• Two 24 V models in 10 A/20 A and 40 A
• Temperature-compensated charging feature,
for a long battery life
• Integrated battery diagnostics including
continuous availability test
• Status relay and additional transistor outputs for
remote monitoring
• Convenient LED displays for easy error analysis
connectPower battery module
connectPower buffer module
compactPower 1ph unregulated power supplies
• Maintenance-free, lead-acid batteries from
1.3 Ah to 17 Ah
• Integrated temperature sensor for optimal battery
charging
• Integrated fuse for reliable activation
• Support capacity up to 40 A / 30 min or
10 A / 90 min
• Robust metal housing for wall mounting
• Maintenance-free UPS on a capacitor basis, with
a capacity to support 20 A / 200 ms
• Parallel switching to increase the output current
or support time
• Status notification via LED and relay contact
• Single-phase unregulated power supplies
• Compact form
• Standard voltage ~230/400 V to
IEC 38 +/– 15 V tap
• Reliable short-circuit and overload protection
2003670000
III
Product overview
Power supplies – Overview
IV
compactPower 3ph unregulated power supplies
WAVEGUARD
Electrical cabinet socket outlet
• 3-phase unregulated power supplies
• Compact form
• Nominal voltage to IEC 38 +/- 5 V tap
• Reliable short-circuit and overload protection
• Electronic fusing
• Visual fault indication and potential-free contact
• Reset input
• Compact form
• Simple installation in electrical cabinet
• TS 35 module can be rail mounted
• VDE mark of conformity
• Two-pole with earthing contact
2003670000
2003670000
V
Product overview
Find the perfect product to meet your requirement
Our extensive portfolio of power supplies at a glance
85–264
85–264
85–264
85–264
85–264
340–575
340–575
340–575
340–575
85–264
85–264
85–264
85–264
85–277
85–277
85–277
85–277
85–277
85–277
3 x 320–3 x 575
3 x 320–3 x 575
3 x 320–3 x 575
3 x 320–3 x 575
85–277
85–277
85–277
85–277
85–277
85–277
85–264
85–132/187–264
85–264
85–264
85–132/187–264
85–132/187–264
85–132/187–264
85–264
85–132/187–264
85–132/187–264
85–132/187–264
85–132/187–550
85–132/187–550
85–132/187–550
80–370
80–370
80–370
80–370
80–370
450–870
450–870
450–870
450–870
80–370
80–370
80–370
80–370
80–370
80–370
80–370
80–370
80–370
80–370
450–800
450–800
450–800
450–800
80–370
80–370
80–370
80–370
80–370
80–370
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
NO
24 3 72
NO
24 5 120
NO
24 10 240
NO
24 20 480
NO
24 40 960
NO
24 5 120
NO
24 10 240 > 55
NO
24 20 480
NO
24 40 960
NO
12 6 72
NO
12 10 120
NO
48 5 240
NO
48 10 480
CO
24 3 72
CO
24 5 120
CO
24 7.5 180
CO
24 10 240
CO
24 20 480
CO
24 40 960
24 5 120
120% CO
CO
24 10 240
> 60
300% CO
24 20 480
@ 1 s CO
24 40 960
CO
5 14 70
CO
12 6 72
CO
12 10 120
CO
48 5 240
CO
48 10 480
CO
48 20 960
NO
12 6 70
NO
12 12 140
NO
24 3.8 90
NO
24 3.8 90
NO
24 7.5 180
NO
24 15 360
NO
24 25 600
> 40
NO
48 2 96
NO
48 4 192
NO
48 7.5 360
NO
48 12.5 600
NO
24 7.5 180
NO
24 15 360
NO
24 25 600
●
87
●
87
●
90
●
91
●
93
●
87
–25
●
88 > 0.5 II
to
●
+70
89
●
90
●
90
●
90
●
90
●
90
●
90
●
90
●
91
●
91
●
–25 91.5
●
to 92.5
●
90
+70
●
91
> 0.5 III
●
91.5
SEMI F47
● Start-up 92.5
@
●
86
● –40°C 89
●
89
Cl1Div2
●
91
●
91.5
Some not yet awarded
●
92.5
(status July 2014)
82
85
85
85
88
87
–25
89
to
> 1.8 II
87
+70
90
89
91
88
Cl1Div2
88
88
%
%
u
%
Order No.
Field cabinets
Small and series machine construction
Machine construction and plant manufacture
Simple process applications
Process industry
Energy technology
Power distribution
Marine engineering
Approvals
Recommendation for application
Surge category
MTBF time [Mh]
Efficiency [%]
Temperature range [°C]
Side-by-side connectability
Status relay
Additional functions
Power boost [60 s]
Derating at [°C]
Power rating [V]
Rated current [A]
Rated voltage [V]
1
1
1
1
1
3
3
3
3
1
1
1
1
1
1
1
1
1
1
3
3
3
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2
1.2
1.2
Output side
DC input voltage [V]
PRO ECO 72 W 24 V 3 A
PRO ECO 120 W 24 V 5 A
PRO ECO 240 W 24 V 10 A
PRO ECO 480 W 24 V 20 A
PRO ECO 960 W 24 V 40 A
PRO ECO3 120 W 24 V 5 A
PRO ECO3 240 W 24 V 10 A
PRO ECO3 480 W 24 V 20 A
PRO ECO3 960 W 24 V 40 A
PRO ECO 72 W 12 V 6 A
PRO ECO 120 W 12 V 10 A
PRO ECO 240 W 48 V 5 A
PRO ECO 480 W 48 V 10 A
PRO MAX 72 W 24 V 3 A
PRO MAX 120 W 24 V 5 A
PRO MAX 180 W 24 V 7,5 A
PRO MAX 240 W 24 V 10 A
PRO MAX 480 W 24 V 20 A
PRO MAX 960 W 24 V 40 A
PRO MAX3 120 W 24 V 5 A
PRO MAX3 240 W 24 V 10 A
PRO MAX3 480 W 24 V 20 A
PRO MAX3 960 W 24 V 40 A
PRO MAX 70 W 5 V 14 A
PRO MAX 72 W 12 V 6 A
PRO MAX 120 W 12 V 10 A
PRO MAX 240 W 48 V 5 A
PRO MAX 480 W 48 V 10 A
PRO MAX 960 W 48 V 20 A
CP T SNT 70 W 12 V 6 A
CP T SNT 140 W 12 V 12 A
CP T SNT 90 W 24 V 3.8 A
CP T SNT 90 W 24 V 3.8 A CL2
CP T SNT 180 W 24 V 7.5 A
CP T SNT 360 W 24 V 15 A
CP T SNT 600 W 24 V 25 A
CP T SNT 90 W 48 V 2 A
CP T SNT 180 W 48 V 4 A
CP T SNT 360 W 48 V 7.5 A
CP T SNT 600 W 48 V 12.5 A
CP T SNT2 180 W 24 V 7.5 A
CP T SNT2 360 W 24 V 15 A
CP T SNT2 600 W 24 V 25 A
AC input voltage [V]
Phases
Input side
Description
A.30
PRO-H
A.14
PROmax
A.4
PROeco
Page
Series / family
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
1469470000
1469480000
1469490000
1469510000
1469520000
1469530000
1469540000
1469550000
1469560000
1469570000
1469580000
1469590000
1469610000
1478100000
1478110000
1478120000
1478130000
1478140000
1478150000
1478170000
1478180000
1478190000
1478200000
1478210000
1478220000
1478230000
1478240000
1478250000
1478270000
1105430000
1105440000
1105790000
1194410000
1105810000
1105820000
1105840000
1194420000
1105850000
1105860000
1105870000
1194480000
1194490000
1194310000
NO = NO contact
CO = CO contact
Start-up @ –40°C = In the range of –40 to –25°C the device starts, but some technical parameter may differ (i. e., ripple-voltage).
VI
2003670000
Product overview
B.4
USV
A.39
A.12
Status relay
Parallel connection option
Side-by-side connectability
22.5–29.5
10
240
●
≤5
●
1313320010
–25
to
+70
24
20
480
●
●
CP DC UPS 24 V 20 A/10 A
20–30
Uin–0.3 V
20/10
480/240
●
●
1370050010
CP DC UPS 24 V 40 A
20–30
Uin–0.3 V
40
960
●
●
1370040010
24
24
24
24
24
10 A / 11.3 min.
10 A / 11.3 min.
10 A / 26.5 min.
10 A / 51 min.
10 A / 81 min.
1.3 Ah
3.4 Ah
7.2 Ah
12 Ah
17 Ah
CP A BATTERY 24 V DC 1,3 Ah
CP A BATTERY 24 V DC 3,4 Ah
CP A BATTERY 24 V DC 7,2 Ah
CP A BATTERY 24 V DC 12 Ah
CP A BATTERY 24 V DC 17 Ah
≤2
≤2
≤2
≤2
≤2
●
●
●
●
●
CP T RM 10 (PRO-H redundancy module)
24
24
24–27
15
●
CP T RM 20 (PRO-H redundancy module)
24
24
24–27
25
●
CP DM 10 (diode module)
10–40
UIN–0.7
10
CP DM 20 (diode module)
10–40
UIN–0.7
20
CP M DM 20 (diode module)
18–30
UIN–0.7
20
●
≤5
●
CP M DM 40 (diode module)
18–30
UIN–0.7
40
●
≤5
●
CP M CAP (capacity module)
18–30
UIN
40 A/1 ms
●
≤5
●
1
1
1.5
1.5
2
28
24
22.5
18
10
–10
to
+55
●
●
●
●
●
CP SNT 24 W 28 V 1 A
CP SNT 24 W 24 V 1 A
CP SNT 24 W 15 V 1,5 A
CP SNT 24 W 12 V 1,5 A
CP SNT 24 W 5 V 2 A
85–265
85–265
85–265
85–265
85–265
120–300
120–300
120–300
120–300
120–300
28
24
15
12
5
CP SNT 25 W 5 V 5 A
85–264
110–370
5
4–8
5
25
≤3
●
CP SNT 48 W 12 V 4 A
85–264
110–370
12
9–15
4
48
≤3
●
CP SNT 48 W 24 V 2 A
85–264
110–370
24
15–28
2
48
≤3
●
CP SNT 48 W 48 V 1A
85–264
110–370
48
46–55
1
48
≤3
●
2003670000
0
to
+40
–25
to
+70
A.23
A.24
A.60
INSTAPOWER
Approvals (all CE)
Power rating [W]
24
Temperature range [°C]
Rated current [A]
18–31.2
Order No.
22.5–30
CP DC BUFFER 24 V 20 A
Ergänzungsmodule
Additional functions
Adjustable range [V]
CP DCDC 250 W 24 V 10 A
Output
Rated voltage [V]
AC input voltage [V]
Input
DC input voltage [V]
A.68
DC/DC
Page
Description
Series / family
1251220000
1406930000
1251070000
1251080000
1251090000
1251110000
1105880000
1105890000
8710620000
8768650000
1222210000
–25
to
+70
1222220000
1222240000
–20
to
+50
9928890028
9928890024
9928890015
9928890012
9928890005
8754960000
–10
to
+70
8754970000
8739140000
8879230000
VII
VIII
2003670000
Switch-mode power supplies
Contents
Switch-mode power supplies
Switch-mode power supplies
2003670000
Overview
A.2
connectPower PROeco
A.4
connectPower PROmax
A.14
connectPower PRO-H
A.30
connectPower PRO-E
A.44
connectPower INSTAPOWER
A.60
connectPower WAVEPOWER
A.67
connectPower DC/DC converter
A.68
A
A.1
Switch-mode power supplies
Switch-mode power supplies – Overview
Switch-mode power supplies
A
The switch-mode power supplies feature a high degree
of efficiency, compact dimensions and minimal heat
generation.
switch-mode power supplies can be depended upon for
all applications because of their high efficiency and their
resistance to both short circuits and overloads.
They are an excellent, reliable solution for providing power
in all automation applications – safely providing 24 V DC
voltage.
Weidmüller offers a system of one- and three-phase swtichmode power supplies especially for the PROmax family.
These can be expanded with additional modules to create
whole system solutions. The appropriate system can be
assembled for any type of application: with redundancy
circuits containing decoupled outputs, monitoring of the
output voltage or triggering of circuit breakers.
The different product series are optimised for the automation
industry: they feature Ex approvals for the processing
industry, a flat shape perfect for distribution tasks within
buildings, or provide decentralised control voltages.
All-purpose usage: with a wide range of AC/DC inputs,
single-, double- or three-phase versions, and a wide
temperature range. Additional performance increases
are possible using simple parallel circuitry. Weidmüller
A.2
2003670000
Switch-mode power supplies
Switch-mode power supplies – Overview
AC / DC
International use
Parallel connection
from 3
3
mm
A
A wide-range input (both DC
as well as AC voltages can be used;
no switching required) and extensive
approvals (UL/CSA and GL
(EMC 1 – bridge)).
connectPower
Module power can be increased by
connecting upto five power supplies in
parallel without diode module.
connectPower PROeco
Narrow
connectPower PROmax
Space-saving configuration in the
switching cabinet through very narrow
housing construction and side-by-side
connectability.
connectPower PRO-H
Robust
Wide temperature range from
–25 °C … +70 °C.
connectPower PRO-E
Wide choice
The right power supply for every
application: 1-phase 3 A, 5 A, 7.5 A, 10
A, 20 A, 40 A and 3-phase 5 A, 10 A,
20 A, 40 A.
connectPower INSTAPOWER
connectPower WAVEPOWER
connectPower DC/DC converters
2003670000
A.3
Switch-mode power supplies
connectPower PROeco
PROeco power supplies with basic functionality
and a high level of reliability
• Single- and three-phase switched-mode power supply units
• Slim design
•Largetemperaturerangefrom–25 °Cto70 °C
• The output voltage can be precisely adjusted via the
potentiometer on the front
• Remote monitoring via integrated status relay
• Three-coloured LED indicators for simple error detection
•Advancedvisualwarningat90 %ratedoutputcurrent
• International approvals
A
%
Derating curves
Technical data
≤ 480 Watt
120
Ioutput (% IN)
100
80
60
40
20
0
–25
0
20
30
40
50
Ambient temperature (°C)
60
70
Ioutput (% IN)
100
80
60
40
20
0
–25
A.4
General technical data
Ambient temp. operating / storage temperature
Max. perm. air humidity (operation)
Degree of protection
Class of protection
Pollution degree
Insulation voltage input/output
MTBF
Parallel connection option
Housing version
Mounting position, installation notice
Short-circuit protection
Overload protection
Overtemperature protection
EMC / shock / vibration
Noise emission acc. to EN55022
Noise immunity tests acc. to
960 Watt
120
0
\Ž
20
30
40
50
Ambient temperature (°C)
60
70
Limiting of mains voltage harmonic currents
Resistance against vibration and shock
Electrical safety (applied standards)
Electrical equipment of machines
Safety transformers for switched-mode power units
Machinery with electronic equipment
Safety extra-low voltage
Protective separation / protection against electrical shock
Protection against dangerous shock currents
–25 °C…+70 °C / –40 °C…+85 °C
5 %…95 % RH
IP 20
I, with PE connection
2
3 kV E/A / 2 kV E/earth / 0.5 kV A/earth
> 500.000 h acc. to IEC 1709 (SN29500)
yes, max. 5 without diode module
metal, corrosion resistant
horizontal on mounting rail TS35, 50 mm spacing
top and bottom for free air circulation
Yes, automatic restart
Yes, IU characteristic curve
Yes, automatic restart
Class B
EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields),
EN61000-4-4 (Burst), EN61000-4-5 (Surge),
EN61000-4-6 (conducted), EN61000-4-11 (Dips)
Acc. to EN61000-3-2
1 g acc. to EN50178, shock: 15 g in all directions
Acc. to EN60204
Acc. to EN61558-2-17
Acc. to EN50178 / VDE0160
SELV acc. to EN60950-1, PELV acc. to EN60204-1
VDE0100-410 / acc. to DIN57100-410
Acc. to VDE0106-101
2003670000
connectPower PROeco
Switch-mode power supplies
connectPower PROeco
PRO ECO 120W 24V 5A
PRO ECO 72W 24V 3A
/
1²
$&
'&
3(
/
²
²
1²
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
A
Similar
to illustration
Similar
to illustration
$&
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Ramp-up time / Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Capacitive load
Protection against inverse voltage
Signalling
Indication
Floating contact / Contact load
Relay on/off
General data
Degree of efficiency
Power loss, idling / Power loss, nominal load
Earth leakage current, max.
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Depth x width x height / Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Tightening torque range
Note
Ordering data
Note
2003670000
mm²
mm²
Nm
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
0,55 A @ 230 V AC / 1,04 A @ 110 V AC
0,22 A @ 370 V DC / 0,68 A @ 120 V DC
Yes / max. 40 A
2 A / DI, safety fuse
6 A, Char. B, circuit breaker
2...4 A, Char. C, circuit breaker
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
1,26 A @ 230 V AC / 2,24 A @ 110 V AC
0,39 A @ 370 V DC / 1,16 A @ 120 V DC
Yes / max. 40 A
4 A / DI, safety fuse
6 A, Char. B, circuit breaker
3...5 A, Char. C, circuit breaker
24 V DC ± 1 %
22...28 V (adjustable via potentiometer)
≤ 100 ms / < 50 mVSS @ 24 V DC, IN
3 A at 55 °C
3 A @ 55 °C, 2,25 A @ 70 °C
unrestricted
Yes
24 V DC ± 1 %
22...28 V (adjustable via potentiometer)
≤ 100 ms / < 50 mVSS @ 24 V DC, IN
5 A at 55 °C
5 A @ 55 °C, 3,75 A @ 70 °C
unrestricted
Yes
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
87 %
4 W / 9.5 W
1 mA
> 0.5 @ 230 V AC / > 0.53 @ 115 V AC
> 100 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 5
100 / 34 / 125 mm / 578 g
87 %
4 W / 15 W
1 mA
> 0.5 @ 230 V AC / > 0.53 @ 115 V AC
> 80 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 5
100 / 40 / 125 mm / 680 g
CE; TUEV (EN/IEC 60950-1); cULus; RCM
CE; TUEV (EN/IEC 60950-1); cULus; RCM
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Type
PRO ECO 72W 24V 3A
Output
Screw connection
5 (+,--,13,14)
0.5 / 6
0.5 / 2.5
26 / 12
0.5 / 0.6
Qty.
1
Order No.
1469470000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO ECO 120W 24V 5A
Output
Screw connection
6 (++,--,13,14)
0.5 / 6
0.5 / 2.5
26 / 12
0.5 / 0.6
Qty.
1
Order No.
1469480000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
A.5
Switch-mode power supplies
connectPower PROeco
connectPower PROeco
PRO ECO 480W 24V 20A
PRO ECO 240W 24V 10A
A
Similar
to illustration
Similar
to illustration
/
1²
$&
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Ramp-up time / Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Capacitive load
Protection against inverse voltage
Signalling
Indication
Floating contact / Contact load
Relay on/off
General data
Degree of efficiency
Power loss, idling / Power loss, nominal load
Earth leakage current, max.
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Depth x width x height / Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Tightening torque range
Note
Ordering data
Note
A.6
mm²
mm²
Nm
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
1,23 A @ 230 V AC / 2,47 A @ 110 V AC
1,18 A @ 370 V DC / 2,4 A @ 120 V DC
Yes / max. 15 A
4 A / DI, safety fuse
10 A, Char. B, circuit breaker
3...4 A, Char. C, circuit breaker
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
2,37 A @ 230 V AC / 5,2 A @ 110 V AC
1,55 A @ 370 V DC / 4,65 A @ 120 V DC
Yes / max. 5 A
6 A / DI, safety fuse
16 A, Char. B, circuit breaker
6...8 A, Char. C, circuit breaker
24 V DC ± 1 %
22...28 V (adjustable via potentiometer)
≤ 100 ms / < 50 mVSS @ 24 V DC, IN
10 A @ 55 °C
10 A @ 55 °C, 7.5 A @ 70 °C
unrestricted
Yes
24 V DC ± 1 %
22...28 V (adjustable via potentiometer)
≤ 100 ms / < 50 mVSS @ 24 V DC, IN
20 A @ 55 °C
20 A @ 55 °C, 15 A @ 70 °C
unrestricted
Yes
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
90%
3 W / 24 W
1 mA
> 0.94 @ 230 V AC / > 0.99 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 5
100 / 60 / 125 mm / 1026 g
91%
5 W / 43 W
1 mA
> 0.98 @ 230 V AC / > 0.98 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 3
120 / 100 / 125 mm / 1557 g
CE; TUEV (EN/IEC 60950-1); cULus; RCM
CE; TUEV (EN/IEC 60950-1); cULus; RCM
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Type
PRO ECO 240W 24V 10A
Output
Screw connection
6 (++,--,13,14)
0.5 / 6
0.5 / 2.5
26 / 12
0.5 / 0.6
Qty.
1
Order No.
1469490000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO ECO 480W 24V 20A
Output
Screw connection
7 (++,---,13,14)
0.5 / 6
0.5 / 2.5
26 / 10
0.5 / 0.6
Qty.
1
Order No.
1469510000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
2003670000
connectPower PROeco
Switch-mode power supplies
connectPower PROeco
PRO ECO 960W 24V 40A
A
Similar
to illustration
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
4,6 A @ 230 V AC / 9,9 A @ 110 V AC
2,9 A @ 370 V DC / 9 A @ 120 V DC
Yes / max. 5 A
16 A / DI, safety fuse
20 A, Char. B, circuit breaker
16 A, Char. C, circuit breaker
Output
Rated output voltage
Output voltage
Ramp-up time / Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Capacitive load
Protection against inverse voltage
Signalling
Indication
24 V DC ± 1 %
22...28 V (adjustable via potentiometer)
≤ 100 ms / < 50 mVSS @ 24 V DC, IN
40 A @ 50 °C
40 A @ 50 °C, 24 A @ 70 °C
unrestricted
Yes
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
Floating contact / Contact load
Relay on/off
General data
Degree of efficiency
Power loss, idling / Power loss, nominal load
Earth leakage current, max.
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Depth x width x height / Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Tightening torque range
Note
Ordering data
Note
2003670000
93%
6 W / 76 W
1 mA
> 0.98 @ 230 V AC / > 0.98 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 3
120 / 160 / 125 mm / 3019 g
CE; TUEV (EN/IEC 60950-1); cULus; RCM
mm²
mm²
Nm
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Type
PRO ECO 960W 24V 40A
Output
Screw connection
7 (++,---,13,14)
0.5 / 16
2.5 / 10
22 / 8
0.5 / 0.6
Qty.
1
Order No.
1469520000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
A.7
Switch-mode power supplies
connectPower PROeco
connectPower PROeco
PRO ECO 120W 12V 10A
PRO ECO 72W 12V 6A
A
Similar
to illustration
Similar
to illustration
/
1²
$&
'&
3(
/
²
²
1²
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
$&
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Ramp-up time / Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Capacitive load
Protection against inverse voltage
Signalling
Indication
Floating contact / Contact load
Relay on/off
General data
Degree of efficiency
Power loss, idling / Power loss, nominal load
Earth leakage current, max.
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Depth x width x height / Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Tightening torque range
Note
Ordering data
Note
A.8
mm²
mm²
Nm
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
0.6 A @ 230 V AC / 1.1 A @ 115 V AC
0.25 A @ 370 V DC / 0.7 A @ 120 V DC
Yes / max. 40 A
2 A / DI, safety fuse
6 A, Char. B, circuit breaker
2...4 A, Char. C, circuit breaker
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
1.25 A @ 230 V AC / 2.25 A @ 110 V AC
0.4 A @ 370 V DC / 1.2 A @ 120 V DC
Yes / max. 40 A
4 A / DI, safety fuse
6 A, Char. B, circuit breaker
3...5 A, Char. C, circuit breaker
12 V DC ± 1 %
10...16 V (adjustable via potentiometer)
≤ 100 ms / < 50 mV ss @ 12 V DC, I Nenn
6 A @ 55 °C
6 A @ 55 °C, 4.5 A @ 70 °C
unrestricted
Yes
12 V DC ± 1 %
10...16 V (adjustable via potentiometer)
≤ 100 ms / < 50 mV ss @ 12 V DC, I Nenn
10 A @ 55 °C
10 A @ 55 °C, 7.5 A @ 70 °C
unrestricted
Yes
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
85 %
4 W / 15 W
1 mA
> 0.5 @ 230 V AC / > 0.53 @ 115 V AC
> 100 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 5
100 / 34 / 125 mm / 644 g
87 %
4 W / 20 W
1 mA
> 0.5 @ 230 V AC / > 0.53 @ 115 V AC
> 80 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 5
100 / 40 / 125 mm / 698 g
CE; TUEV (EN/IEC 60950-1); cULus; RCM
CE; TUEV (EN/IEC 60950-1); cULus; RCM
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Type
PRO ECO 72W 12V 6A
Output
Screw connection
5 (+,--,13,14)
0.5 / 6
0.5 / 2.5
26 / 12
0.5 / 0.6
Qty.
1
Order No.
1469570000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO ECO 120W 12V 10A
Output
Screw connection
6 (++,--,13,14)
0.5 / 6
0.5 / 2.5
26 / 12
0.5 / 0.6
Qty.
1
Order No.
1469580000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
2003670000
connectPower PROeco
Switch-mode power supplies
connectPower PROeco
PRO ECO 480W 48V 10A
PRO ECO 240W 48V 5A
/
1²
$&
²
²
'&
3(
A
Similar
to illustration
Similar
to illustration
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
1.2 A @ 230 V AC / 2.4 A @ 115 V AC
1.2 A @ 370 V DC / 2.4 A @ 120 V DC
Yes / Max. 10 A
4 A / DI, safety fuse
10 A, Char. B, circuit breaker
3...4 A, Char. C, circuit breaker
100...240 V AC (wide-range input)
85…264 V AC (Derating @ 100 V AC)
47...63 Hz
80…370 V DC (Derating @ 120 V DC)
2.4 A @ 230 V AC / 5.2 A @ 110 V AC
1.5 A @ 370 V DC / 4.6 A @ 120 V DC
Yes / max. 3 A
6 A / DI, safety fuse
16 A, Char. B, circuit breaker
6...8 A, Char. C, circuit breaker
48 V DC ± 1 %
42...56 V (adjustable via potentiometer)
≤ 100 ms / < 100 mV ss @ 48 V DC, I Nenn
5 A at 55 °C
5 A @ 55 °C, 3,75 A @ 70 °C
unrestricted
Yes
48 V DC ± 1 %
42...56 V (adjustable via potentiometer)
≤ 100 ms / < 100 mV ss @ 48 V DC, I Nenn
10 A @ 55 °C
10 A @ 55 °C, 7.5 A @ 70 °C
unrestricted
Yes
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
92 %
5 W / 50 W
1 mA
> 0.94 @ 230 V AC / > 0.99 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 5
100 / 60 / 125 mm / 1076 g
93%
3 W / 23 W
1 mA
> 0.98 @ 230 V AC / > 0.98 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
yes, max. 3
120 / 100 / 125 mm / 1570 g
CE; TUEV (EN/IEC 60950-1); cULus; RCM
CE; TUEV (EN/IEC 60950-1); cULus; RCM
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Ramp-up time / Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Capacitive load
Protection against inverse voltage
Signalling
Indication
Floating contact / Contact load
Relay on/off
General data
Degree of efficiency
Power loss, idling / Power loss, nominal load
Earth leakage current, max.
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Depth x width x height / Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Tightening torque range
Note
Ordering data
Note
2003670000
mm²
mm²
Nm
Type
PRO ECO 240W 48V 5A
Output
Screw connection
6 (++,--,13,14)
0.5 / 6
0.5 / 2.5
26 / 12
0.5 / 0.6
Qty.
1
Order No.
1469590000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO ECO 480W 48V 10A
Output
Screw connection
7 (++,---,13,14)
0.5 / 6
0.22 / 4
26 / 10
0.5 / 0.6
Qty.
1
Order No.
1469610000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
A.9
Switch-mode power supplies
connectPower PROeco
connectPower PROeco
PRO ECO3 240W 24V 10A
PRO ECO3 120W 24V 5A
A
Similar
to illustration
Similar
to illustration
/
/²
/
$&
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
/
/²
/
$&
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Ramp-up time / Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Capacitive load
Protection against inverse voltage
Signalling
Indication
Floating contact / Contact load
Relay on/off
General data
Degree of efficiency
Power loss, idling / Power loss, nominal load
Earth leakage current, max.
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Depth x width x height / Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Tightening torque range
Note
Ordering data
Note
A.10
mm²
mm²
Nm
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
47...63 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
0.3 A @ 3 x 500 V AC / 0.4 A @ 3 x 400 V AC
0.2 A @ 800 V DC / 0.4 A @ 450 V DC
Yes / max. 40 A
2 A / DI, safety fuse
2...3 A, Char. C, circuit breaker
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
47...63 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
0.6 A @ 3 x 500 V AC / 0.8 A @ 3 x 400 V AC
0.4 A @ 800 V DC / 0.7 A @ 450 V DC
Yes / max. 50 A
2 A / DI, safety fuse
2...3 A, Char. C, circuit breaker
24 V DC ± 1 %
22...28 V (adjustable via potentiometer)
≤ 100 ms / < 50 mVSS @ 24 V DC, IN
5 A at 55 °C
5 A @ 55 °C, 3,75 A @ 70 °C
unrestricted
Yes
24 V DC ± 1 %
22...28 V (adjustable via potentiometer)
≤ 100 ms / < 50 mVSS @ 24 V DC, IN
10 A @ 55 °C
10 A @ 55 °C, 7.5 A @ 70 °C
unrestricted
Yes
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
87 %
6 W / 13 W
1 mA
> 0.55 @ 3 x 500 V AC / > 0.65 @ 3 x 400 V AC
> 40 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC
yes, max. 5
100 / 40 / 125 mm / 710 g
88%
6 W / 24 W
1 mA
> 0.55 @ 3 x 500 V AC / > 0.65 @ 3 x 400 V AC
> 40 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC
yes, max. 5
100 / 60 / 125 mm / 971 g
CE; TUEV (EN/IEC 60950-1); cULus; RCM
CE; TUEV (EN/IEC 60950-1); cULus; RCM
Input
Screw connection
4 for L1/L2/L3/PE
0.5 / 6
0.5 / 2.5
26 / 12
Input
Screw connection
4 for L1/L2/L3/PE
0.5 / 6
0.5 / 2.5
26 / 12
Type
PRO ECO3 120W 24V 5A
Output
Screw connection
6 (++,--,13,14)
0.5 / 6
0.5 / 2.5
26 / 12
0.5 / 0.6
Qty.
1
Order No.
1469530000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO ECO3 240W 24V 10A
Output
Screw connection
6 (++,--,13,14)
0.5 / 6
0.5 / 2.5
26 / 12
0.5 / 0.6
Qty.
1
Order No.
1469540000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
2003670000
connectPower PROeco
Switch-mode power supplies
connectPower PROeco
PRO ECO3 960W 24V 40A
PRO ECO3 480W 24V 20A
Similar
to illustration
Similar
to illustration
/
/²
/
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
/
/²
/
$&
²
²
²
'&
3(
A
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Ramp-up time / Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Capacitive load
Protection against inverse voltage
Signalling
Indication
Floating contact / Contact load
Relay on/off
General data
Degree of efficiency
Power loss, idling / Power loss, nominal load
Earth leakage current, max.
Power factor (approx.)
AC failure bridging time @ INom
Parallel connection option
Depth x width x height / Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Tightening torque range
Note
Ordering data
Note
2003670000
mm²
mm²
Nm
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
47...63 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
1.2 A @ 3 x 500 V AC / 1.5 A @ 3 x 400 V AC
0.7 A @ 800 V DC / 1.2 A @ 450 V DC
Yes / max. 50 A
4 A / DI, safety fuse
3...5 A, Char. C, circuit breaker
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
47...63 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
2,15 A @ 3 x 500 V AC / 2,68 A @ 3 x 400 V AC
1,37 A @ 800 V DC / 2,37 A @ 450 V DC
Yes / max. 40 A
6 A / DI, safety fuse
10 A, Char. B, circuit breaker
6...8 A, Char, C, circuit breaker
24 V DC ± 1 %
22...28 V (adjustable via potentiometer)
≤ 100 ms / < 50 mVSS @ 24 V DC, IN
20 A @ 55 °C
20 A @ 55 °C, 15 A @ 70 °C
unrestricted
Yes
24 V DC ± 1 %
22...28 V (adjustable via potentiometer)
≤ 100 ms / < 50 mVSS @ 24 V DC, IN
40 A @ 50 °C
40 A @ 50 °C, 24 A @ 70 °C
unrestricted
Yes
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
LED green (Uoutput > 21.6 V DC), LED yellow (Ioutput > 90% IRated typ. ),
LED red (overload, overtemperature, short-circuit, Uoutput < 20.4 V DC)
Yes / max. 30 V DC / 1 A
Output voltage > 21.6 V / < 20.4 V, overload
89%
8 W / 48 W
1 mA
> 0.55 @ 3 x 500 V AC / > 0.65 @ 3 x 400 V AC
> 30 ms @ 3 x 500 V AC / > 20 ms @ 3 x 400 V AC
yes, max. 3
120 / 100 / 125 mm / 1495 g
90%
5 W / 95 W
1 mA
> 0.55 @ 3 x 500 V AC / > 0.65 @ 3 x 400 V AC
> 25 ms at 3 x 500 V AC / > 20 ms at 3 x 400 V AC
yes, max. 3
120 / 160 / 125 mm / 2899 g
CE; TUEV (EN/IEC 60950-1); cULus; RCM
CE; TUEV (EN/IEC 60950-1); cULus; RCM
Input
Screw connection
4 for L1/L2/L3/PE
0.5 / 6
0.5 / 2.5
26 / 12
Input
Screw connection
4 for L1/L2/L3/PE
0.5 / 6
0.5 / 2.5
26 / 12
Type
PRO ECO3 480W 24V 20A
Output
Screw connection
7 (++,---,13,14)
0.5 / 6
0.5 / 2.5
26 / 10
0.5 / 0.6
Qty.
1
Order No.
1469550000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO ECO3 960W 24V 40A
Output
Screw connection
7 (++,---,13,14)
0.5 / 16
2.5 / 10
22 / 8
0.5 / 0.6
Qty.
1
Order No.
1469560000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
A.11
Switch-mode power supplies
connectPower PROeco
connectPower PROeco diode module
CP DM 10
CP DM 20
A
+V
E1
E2
–V
–V
DC
E1 E2 –V
-V
+V
-V
+
+V –V
DC
–
E1
E2
-V
E1
E2
-V
Technical data
Input
Input voltage
Input current
Output
Output voltage
Output current
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Mounting position, installation notice
Installation advice
Weight
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
40 V DC max.
2 x 0...10 A max.
40 V DC max.
2 x 0...20 A max.
Uin - 0.5 V typical
0...20 A max. or 10 A max. for redundancy operation
Uin - 0.5 V typical
0...40 A max. or 20 A max. for redundant operations
-10 °C...55 °C
-20 °C...85 °C
95.5%
horizontally, on terminal rail TS 35
Clearance: side ≥ 2 cm; above/below ≥ 10 cm
399 g
CE; cULus; cURus; EAC
-10 °C...55 °C
-20 °C...85 °C
97.5%
horizontally, on terminal rail TS 35
Clearance: side ≥ 2 cm; above/below ≥ 10 cm
411 g
CE; cULus; cURus; EAC
Input
4 / 0.13 / 6
110 / 55.5 / 125
Input
4 / 0.13 / 6
110 / 55.5 / 125
Type
CP DM 10
Output
4 / 0.13 / 6
110 / 55.5 / 125
Qty.
1
Order No.
8710620000
Type
CP DM 20
Output
10 / 0.32 / 16
110 / 55.5 / 125
Qty.
1
Order No.
8768650000
Note
Accessories
Note
A.12
2003670000
Small metal foot
Type
MTA 30 MF
Large metal foot
Order No.
1251320000
Small wall mounting
Type
CP A WALLADAPTER 30 MM
Small plastic foot
Type
MTA 45 MF
Order No.
1251310000
Type
MTA 30 BK
Switch-mode power supplies
connectPower PROeco - Accessories
Large plastic foot
Order No.
1168970000
Type
MTA 45 BK
Order No.
1962250000
A
Large wall mounting
Order No.
1461870000
Type
CP A WALLADAPTER 45 MM
Order No.
1461850000
Small screwdriver
Type
SDIK PH1
SDIS 0.5X3.0X100
Blade type
Size/AF
1.00
B
a
b
0.5
3
c
80
100
Order No.
9008570000
9008380000
End bracket
Markers
For DIN rail TS 35
Type
SM 18/9.5 K MC NE WS
2003670000
Colour
white
Qty.
200
Order No.
1248580000
Polyamide with fibre glass, screwable
WEW 35/1 SW
Colour
black
Torque
1.2 Nm
Qty.
50
Order No.
1162600000
A.13
Switch-mode power supplies
connectPower PROmax
connectPower
PROmax
A
Derating curve
Technical data
/RDG
7HPSƒ&
Max. limiting average on state current [A]
Typ\Temp.
45 °C 50 °C 55 °C 60 °C 65 °C 70 °C
1ph 24 V / 3 A
3,6
3,3
3,2
3
2,6
2,2
1ph 24 V / 5 A
6
5,7
5,4
5
4,4
3,8
1ph 24 V / 7,5 A
9
8,5
8
7,5
6,6
5,6
1ph 24 V / 10 A
12
11,3 10,7
10
8,8
7,5
1ph 24 V / 20 A
24
22,6 21,4
20
17,6
15
1ph 24 V / 40 A
48
45,2 42,8
40
35,2
30
1ph 5 V / 14 A
16,8 15,8
15
14
12,3 10,5
1ph 12 V / 6 A
7,2
6,8
6,4
6
5,3
4,5
1ph 12 V / 10 A
12
11,3 10,7
10
8,8
7,5
1ph 48 V / 5 A
6
5,7
5,4
5
4,4
3,8
1ph 48 V / 10 A
12
11,3 10,7
10
8,8
7,5
1ph 48 V / 20 A
24
22,6 21,4
20
17,6
15
3ph 24 V / 5 A
6
5,7
5,4
5
4,4
3,8
3ph 24 V / 10 A
12
11,3 10,7
10
8,8
7,5
3ph 24 V / 20 A
24
22,6 21,4
20
17,6
15
3ph 24 V / 40 A
48
45,2 42,8
40
35,2
30
A.14
General technical data
Current limiting
Insulation voltage input earth
Insulation voltage output earth
Insulation voltage input/output
Earth leakage current
Series switching capability
Ambient temp. operating / storage temperature / Start up
Humidity at operating temperature
Class of protection / Pollution degree
MTBF
Housing version
Status indication
Mounting position, installation notice
EMC / shock / vibration
Noise immunity tests acc. to
Resistance against vibration and shock
Electrical safety (applied standards)
Electrical equipment of machines
Safety transformers for switched-mode power units
Machinery with electronic equipment
Safety extra-low voltage
Protective separation / protection against electrical shock
Protection against dangerous shock currents
> 120 % IN
3.5 kV
0.5 kV
4 kV
3.5 mA
Yes
-25 °C...+70 °C / -40 °C...+85 °C / ≥ -40 °C
5...95 %, no condensation
I/2
>500,000h (25°C, IEC 61709)
Metal, corrosion resistant
LED red/green and relay (≥21.6 V DC LED green, relay on/ ≤20.6 LED
red, relay off)
Horizontal on TS35 mounting rail, with 50 mm of clearance at top and bottom
for air circulation. Can be mounted side by side with no space in between.
EN55024; EN55022; IEC61000-3-2,-3; IEC61000-4-2,-3,-4,-5,-6,-8,-11
2.3 g / 30 g in all directions
Acc. to EN60204
Acc. to EN61558-2-16
Acc. to EN50178 / VDE0160
SELV acc. to EN60950, PELV acc. to EN60204, IEC61204
VDE0100-410 / acc. to DIN57100-410
Acc. to VDE0106-101
2003670000
connectPower PROmax
PRO MAX 72W 24V 3A
Switch-mode power supplies
connectPower PROmax
PRO MAX 120W 24V 5A
A
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Power boost @ URated
Pulsed current capacity @ URated
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Protection against reverse voltages from the load
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Screwdriver blade
Note
Ordering data
Note
mm²
mm²
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
1 A @ 230 V AC / 1.5 A @ 115 V AC
1A @ 370 VDC / 1,5A @ 120 VDC
Yes / max. 15 A
6 A, Char. B, circuit breaker, 3 - 5 A Char. C, circuit breaker
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
1A @ 230 VAC / 2,5A @ 115 VAC
1,5A @ 370 VDC / 2,5A @ 120 VDC
Yes / max. 15 A
6 A, Char. B, circuit breaker, 6 A, char. C circuit breaker
24 V DC ± 1 %
22.5...29.5 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
3 A @ 60 °C
3,6 A @ 45°C, 2,25 A @ 70°C
3.6 A (1 min), 4.5 A (4s)
9 A (2ms)
24 V DC ± 1 %
22.5...29.5 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
5 A @ 60 °C
6.0 A @ 45 °C, 3,75 A @ 70 °C
6 A (1 min), 7.5 A (4s)
15 A (2ms)
89%
> 0.90 @ 230 V AC
min. 20 ms
30…35 V DC
yes, max. 5
125 / 32 / 130 mm
650 g
89%
> 0.90 @ 230 V AC
min. 20 ms
30…35 V DC
yes, max. 5
125 / 40 / 130 mm
859 g
CE; cULus; cULusEX; cURus; EAC; TUEV
CE; cULus; cULusEX; cURus; EAC; TUEV
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Type
PRO MAX 72W 24V 3A
Output
Screw connection
8 (++,---,11,13,14)
0.5 / 6
0.5 / 4
26 / 12
0.6 x 3.5
Qty.
1
Order No.
1478100000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO MAX 120W 24V 5A
Output
Screw connection
8 (++,---,11,13,14)
0.5 / 6
0.5 / 4
26 / 12
0.6 x 3.5
Qty.
1
Order No.
1478110000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
2003670000
A.15
Switch-mode power supplies
connectPower PROmax
connectPower PROmax
PRO MAX 180W 24V 7,5A
PRO MAX 240W 24V 10A
A
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Power boost @ URated
Pulsed current capacity @ URated
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Protection against reverse voltages from the load
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Screwdriver blade
Note
Ordering data
Note
mm²
mm²
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
1 A @ 230 V AC / 2 A @ 115 V AC
1A @ 370 VDC / 2A @ 120 VDC
Yes / max. 15 A
10 A, char. B circuit breaker, 6…8 A, char. C circuit breaker
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
1.5 A @ 230 V AC / 3 A @ 115 V AC
1,5A @ 370 VDC / 3A @ 120 VDC
Yes / max. 15 A
10 A, char. B circuit breaker, 6…8 A, char. C circuit breaker
24 V DC ± 1 %
22.5...29.5 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
7,5 A @ 60 °C
9 A @ 45°C, 5,6 A @ 70°C
9 A (1 min), 11.25 A (4s)
22,5 A (2ms)
24 V DC ± 1 %
22.5...29.5 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
10 A @ 60 °C
12 A @ 45°C, 7,5 A @ 70°C
12 A (1 min), 15 A (4s)
30 A (2ms)
91.5%
> 0.95 @ 230 V AC
min. 20 ms
30…35 V DC
yes, max. 5
125 / 50 / 130 mm
950 g
91.5%
> 0.95 @ 230 V AC
min. 20 ms
30…35 V DC
yes, max. 5
125 / 60 / 130 mm
1050 g
CE; cULus; cULusEX; cURus; EAC; TUEV
CE; cULus; cULusEX; cURus; EAC; TUEV
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Type
PRO MAX 180W 24V 7,5A
Output
Screw connection
8 (++,---,11,13,14)
0.5 / 6
0.5 / 4
26 / 12
0.6 x 3.5
Qty.
1
Order No.
1478120000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO MAX 240W 24V 10A
Output
Screw connection
8 (++,---,11,13,14)
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Qty.
1
Order No.
1478130000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
A.16
2003670000
connectPower PROmax
PRO MAX 480W 24V 20A
Switch-mode power supplies
connectPower PROmax
PRO MAX 960W 24V 40A
A
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Power boost @ URated
Pulsed current capacity @ URated
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Protection against reverse voltages from the load
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Screwdriver blade
Note
Ordering data
Note
mm²
mm²
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
2,3A @ 230 VAC / 4,8A @ 115 VAC
1,5A @ 370 VDC / 4.8A @ 120 VDC
Yes / max. 15 A
16 A, Char. B circuit breaker, 10 A, char. C circuit breaker
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
4,52A @ 230 VAC / 10A @ 115 VAC
2,8A @ 370 VDC / 10A @ 120 VDC
Yes / max. 15 A
20 A, char. B circuit breaker, 16 A, Char. C circuit breaker
24 V DC ± 1 %
22.5...29.5 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
20 A @ 60 °C
24 A @ 45°C, 15 A @ 70°C
24 A (1 min), 30 A (4s), 100…240 V AC
60 A (2ms)
24 V DC ± 1 %
22.5...29.5 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
40 A @ 60 °C
48 A @ 45°C, 30 A @ 70°C
48 A (1 min), 60 A (4s), 100…240 V AC
120 A (2ms)
92 %
> 0.95 @ 230 V AC
min. 20 ms
30…35 V DC
yes, max. 3
150 / 90 / 130 mm
2000 g
93%
> 0.95 @ 230 V AC
min. 20 ms
30…35 V DC
yes, max. 3
150 / 140 / 130 mm
3900 g
CE; cULus; cULusEX; cURus; EAC; TUEV
CE; cULus; cULusEX; cURus; EAC; TUEV
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Type
PRO MAX 480W 24V 20A
Output
Screw connection
8 (++,---,11,13,14)
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Qty.
1
Order No.
1478140000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO MAX 960W 24V 40A
Output
Screw connection
8 (++,---,11,13,14)
0.5 / 16
0.5 / 16
22 / 8
1.0 x 5.5
Qty.
1
Order No.
1478150000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
2003670000
A.17
Switch-mode power supplies
connectPower PROmax
connectPower PROmax
PRO MAX 70W 5V 14A
PRO MAX 72W 12V 6A
A
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Power boost @ URated
Pulsed current capacity @ URated
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Protection against reverse voltages from the load
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Screwdriver blade
Note
Ordering data
Note
mm²
mm²
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
1 A @ 230 V AC / 1.5 A @ 115 V AC
1A @ 370 VDC / 1,5A @ 120 VDC
Yes / max. 15 A
6 A, Char. B, circuit breaker, 3 - 5 A Char. C, circuit breaker
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
1 A @ 230 V AC / 1.5 A @ 115 V AC
1A @ 370 VDC / 1,5A @ 120 VDC
Yes / max. 15 A
6 A, Char. B, circuit breaker, 3 - 5 A Char. C, circuit breaker
5 V DC
4.5...7 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
14 A @ 60°C
16,8 A @ 45°C, 10,5 A @ 70°C
16.8 A (1 min), 21 A (4s)
42 A (2ms)
12 V DC ± 1 %
10...15 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
6 A @ 60°C
7.2 A @ 45°C, 4.5 A @ 70°C
7.2 A (1 min), 9 A (4s)
18 A (2ms)
86%
> 0.90 @ 230 V AC
min. 20 ms
> 7.5 V DC
yes, max. 5
125 / 32 / 130 mm
650 g
89%
> 0.90 @ 230 V AC
min. 20 ms
> 18 V DC
yes, max. 5
125 / 32 / 130 mm
650 g
CE; cULus; cULusEX; cURus; EAC; TUEV
CE; cULus; cULusEX; cURus; EAC; TUEV
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Type
PRO MAX 70W 5V 14A
Output
Screw connection
8 (++,---,11,13,14)
0.5 / 6
0.5 / 4
26 / 12
0.6 x 3.5
Qty.
1
Order No.
1478210000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO MAX 72W 12V 6A
Output
Screw connection
8 (++,---,11,13,14)
0.5 / 6
0.5 / 4
26 / 12
0.6 x 3.5
Qty.
1
Order No.
1478220000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
A.18
2003670000
connectPower PROmax
PRO MAX 120W 12V 10A
Switch-mode power supplies
connectPower PROmax
PRO MAX 240W 48V 5A
A
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Power boost @ URated
Pulsed current capacity @ URated
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Protection against reverse voltages from the load
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Screwdriver blade
Note
Ordering data
Note
mm²
mm²
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
1A @ 230 VAC / 2,5A @ 115 VAC
1,5A @ 370 VDC / 2,5A @ 120 VDC
Yes / max. 15 A
6 A, Char. B, circuit breaker, 6 A, char. C circuit breaker
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
1.5 A @ 230 V AC / 3 A @ 115 V AC
1,5A @ 370 VDC / 3A @ 120 VDC
Yes / max. 15 A
10 A, char. B circuit breaker, 6…8 A, char. C circuit breaker
12 V DC ± 1 %
10...15 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
10 A @ 60 °C
12 A @ 45°C, 7,5 A @ 70°C
12 A (1 min), 15 A (4s)
30 A (2ms)
48 V DC ± 1 %
30...56 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
5 A @ 60 °C
6.0 A @ 45 °C, 3,75 A @ 70 °C
5 A (1 min), 7.5 A (4s)
15 A (2ms)
89%
> 0.90 @ 230 V AC
min. 20 ms
> 18 V DC
yes, max. 5
125 / 40 / 130 mm
850 g
92.5%
> 0.95 @ 230 V AC
min. 20 ms
58 … 65 V DC
yes, max. 5
125 / 60 / 130 mm
1050 g
CE; cULus; cULusEX; cURus; EAC; TUEV
CE; cULus; cULusEX; cURus; EAC; TUEV
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Type
PRO MAX 120W 12V 10A
Output
Screw connection
8 (++,---,11,13,14)
0.5 / 6
0.5 / 4
26 / 12
0.6 x 3.5
Qty.
1
Order No.
1478230000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO MAX 240W 48V 5A
Output
Screw connection
8 (++,---,11,13,14)
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Qty.
1
Order No.
1478240000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
2003670000
A.19
Switch-mode power supplies
connectPower PROmax
connectPower PROmax
PRO MAX 480W 48V 10A
PRO MAX 960W 48V 20A
A
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
/
1²
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Power boost @ URated
Pulsed current capacity @ URated
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Protection against reverse voltages from the load
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Screwdriver blade
Note
Ordering data
Note
mm²
mm²
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
2,3A @ 230 VAC / 4,8A @ 115 VAC
1,5A @ 370 VDC / 4.8A @ 120 VDC
Yes / max. 15 A
16 A, Char. B circuit breaker, 10 A, char. C circuit breaker
100...240 V AC (wide-range input)
85…277 V AC
45…65 Hz
80...370 V DC
4,52A @ 230 VAC / 10A @ 115 VAC
2,8A @ 370 VDC / 10A @ 120 VDC
Yes / max. 15 A
20 A, char. B circuit breaker, 16 A, Char. C circuit breaker
48 V DC ± 1 %
30...56 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
10 A @ 60 °C
12 A @ 45°C, 7,5 A @ 70°C
12 A (1 min), 15 A (4s), 100…240 V AC
60 A (2ms)
48 V DC ± 1 %
30...56 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
20 A @ 60 °C
24 A @ 45°C, 15 A @ 70°C
24 A (1 min), 30 A (4s), 100…240 V AC
60 A (2ms)
93%
> 0.95 @ 230 V AC
min. 20 ms
58 … 65 V DC
yes, max. 5
150 / 90 / 130 mm
2000 g
94%
> 0.95 @ 230 V AC
min. 20 ms
58 … 65 V DC
yes, max. 5
150 / 140 / 130 mm
1350 g
CE; cULus; cULusEX; cURus; EAC; TUEV
CE; cULus; cULusEX; cURus; EAC; TUEV
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Input
Screw connection
3 for L/N/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Type
PRO MAX 480W 48V 10A
Output
Screw connection
8 (++,---,11,13,14)
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Qty.
1
Order No.
1478250000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO MAX 960W 48V 20A
Output
Screw connection
8 (++,---,11,13,14)
0.5 / 16
0.5 / 16
22 / 8
1.0 x 5.5
Qty.
1
Order No.
1478270000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
A.20
2003670000
connectPower PROmax
PRO MAX3 120W 24V 5A
Switch-mode power supplies
connectPower PROmax
PRO MAX3 240W 24V 10A
A
/
/²
/
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
/
/²
/
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Power boost @ URated
Pulsed current capacity @ URated
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Protection against reverse voltages from the load
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Screwdriver blade
Note
Ordering data
Note
mm²
mm²
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
45…65 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
0,28A @ 3*500 VAC / 0,3A @ 3*400 VAC
0.18 A @ 800 V DC / 0.3 A @ 450 V DC
Yes / max. 15 A
2…3 A, char. C circuit breaker
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
45…65 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
0,35A @ 3*500 VAC / 0,4A @ 3*400 VAC
0.35 A @ 800 V DC / 0.6 A @ 450 V DC
Yes / max. 15 A
3 - 5 A Char. C, circuit breaker
24 V DC ± 1 %
22.5...29.5 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
5 A @ 60 °C
6.0 A @ 45 °C, 3,75 A @ 70 °C
6 A (1 min), 7.5 A (4s), 400…500 V AC
15 A (2ms)
24 V DC ± 1 %
22.5...29.5 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
10 A @ 60 °C
12 A @ 45°C, 7,5 A @ 70°C
12 A (1 min), 15 A (4s)
30 A (2ms)
90%
> 0.50 @ 3*400 V AC
min. 20 ms
30…35 V DC
yes, max. 5
125 / 40 / 130 mm
850 g
91.5%
> 0.85 @ 3*400 V AC
min. 20 ms
30…35 V DC
yes, max. 5
125 / 60 / 130 mm
1350 g
CE; cULus; cULusEX; cURus; EAC; TUEV
CE; cULus; cULusEX; cURus; EAC; TUEV
Input
Screw connection
4 for L1/L2/L3/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Input
Screw connection
4 for L1/L2/L3/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Type
PRO MAX3 120W 24V 5A
Output
Screw connection
8 (++,---,11,13,14)
0.5 / 6
0.5 / 4
26 / 12
0.6 x 3.5
Qty.
1
Order No.
1478170000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO MAX3 240W 24V 10A
Output
Screw connection
8 (++,---,11,13,14)
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Qty.
1
Order No.
1478180000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
2003670000
A.21
Switch-mode power supplies
connectPower PROmax
connectPower PROmax
PRO MAX3 480W 24V 20A
PRO MAX3 960W 24V 40A
A
/
/²
/
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
/
/²
/
$&
²
²
²
'&
3(
3D\DWWHQWLRQWRSRODULW\RI'&FRQQHFWLRQ
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Continuous output current @ URated
Power boost @ URated
Pulsed current capacity @ URated
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Protection against reverse voltages from the load
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Connection system
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Screwdriver blade
Note
Ordering data
Note
mm²
mm²
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
45…65 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
0,7A @ 3*500 VAC / 0,85 @ 3*400 VAC
0.7 A @ 800 V DC / 1.2 A @ 450 V DC
Yes / max. 15 A
3 - 5 A Char. C, circuit breaker
3 x 400...3 x 500 V AC (wide-range input)
3 x 320...3 x 575 V AC / 2 x 360...2 x 575 V AC
45…65 Hz
450...800 V DC (max. 500 V DC acc. to UL508)
1,3A @ 3*500 VAC / 1,6A @ 3*400 VAC
1.4 A @ 800 V DC / 2.4 A @ 450 V DC
Yes / max. 15 A
6…8 A, char. C circuit breaker
24 V DC ± 1 %
22.5...29.5 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
20 A @ 60 °C
24 A @ 45°C, 15 A @ 70°C
24 A (1 min), 30 A (4s)
60 A (2ms)
24 V DC ± 1 %
22.5...29.5 V (adjustable via potentiometer)
< 50 mVss @ UNenn, Full Load
40 A @ 60 °C
48 A @ 45°C, 30 A @ 70°C
48 A (1 min), 60 A (4s), 400…500 V AC
120 A (2ms)
91.5%
> 0.85 @ 3*400 V AC
min. 20 ms
30…35 V DC
yes, max. 3
150 / 70 / 130 mm
1600 g
93.5%
> 0.75 @ 3*400 V AC
min. 20 ms
30…35 V DC
yes, max. 3
150 / 140 / 130 mm
3400 g
CE; cULus; cULusEX; cURus; EAC; TUEV
CE; cULus; cULusEX; cURus; EAC; TUEV
Input
Screw connection
4 for L1/L2/L3/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Input
Screw connection
4 for L1/L2/L3/PE
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Type
PRO MAX3 480W 24V 20A
Output
Screw connection
8 (++,---,11,13,14)
0.18 / 6
0.22 / 4
26 / 10
0.8 x 4.0, PZ 1
Qty.
1
Order No.
1478190000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Type
PRO MAX3 960W 24V 40A
Output
Screw connection
8 (++,---,11,13,14)
0.5 / 16
0.5 / 16
22 / 8
1.0 x 5.5
Qty.
1
Order No.
1478200000
The internal varistor found in a switch-mode power supply does not replace the
need for surge protection within a system.
Accessories
Note
A.22
2003670000
PRO-M: diode, capacity
and relay modules
CP M DM20
CP M DM40
1+
12-
Switch-mode power supplies
connectPower PROmax
3+
4+
11
12
14
34-
21
22
24
2+
1+
12-
3+
4+
11
12
14
A
34-
21
22
24
2+
Technical data
Input
Rated input voltage / DC input voltage range
Input current
Output
Rated output voltage / Output voltage
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
Voltage monitoring / Floating contact
Switching thresholds
24 V DC / 18…30 V DC
2 x 10 A or 1 x 20 A
24 V DC / 18…30 V DC
2 x 20 A or 1 x 40 A
24 V DC ± 1 % / Input voltage - 0.7 V
20 A @ 60 °C
24 A @ 45 °C, 22.5 A @ 55 °C, 15 A @ 70 °C
Yes, In both inputs / Yes
21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for
Power Fail
24 V DC ± 1 % / Input voltage - 0.7 V
40 A @ 60 °C
48 A @ 45 °C, 45 A @ 55 °C, 30 A @ 70 °C
Yes, In both inputs / Yes
21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for
Power Fail
> 97% @ 24 V input voltage
150 / 34 / 130 mm / 0.3 kg
-25 °C...70 °C / -40 °C...85 °C
5...95 %, no condensation
IP 20 / III, with no ground connection, for SELV / 2
0.5 kV Input/output housing
> 500,000 h acc. to IEC 1709 (SN29500
Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom
for air circ. Can mount side by side with no space in between.
> 97% @ 24 V input voltage
150 / 60 / 130 mm / 0.6 kg
-25 °C...70 °C / -40 °C...85 °C
5...95 %, no condensation
IP 20 / III, with no ground connection, for SELV / 2
0.5 kV Input/output housing
> 500,000 h acc. to IEC 1709 (SN29500
Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom
for air circ. Can mount side by side with no space in between.
Class B
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN
61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)
Class B
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN
61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6 (conducted)
Resistance to vibration / Shock
Electrical safety (applied standards)
Electrical machine equipment
For use with electronic equipment
Safety extra-low voltage
Approvals
Approvals
1 g according to EN50178 / 15 g In all directions
1 g according to EN50178 / 15 g In all directions
Acc. to EN60204
Acc. to EN50178 / VDE0160
SELV acc. to EN60950, PELV acc. to EN60204
Acc. to EN60204
Acc. to EN50178 / VDE0160
SELV acc. to EN60950, PELV acc. to EN60204
cCSAus; CE; cULus; EAC; GL; GOSTME25
cCSAus; CE; cULus; EAC; GL; GOSTME25
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Input
Screw connection
4 (1+, 2+, 1-, 2-)
0.5 / 6
0.5 / 2.5
26 / 12
Input
Screw connection
4 (1+, 2+, 1-, 2-)
0.5 / 16
2.5 / 10
22 / 6
General data
Degree of efficiency
Depth x width x height / Weight
Ambient temperature (operational) / Storage temperature
Humidity
Protection degree / Class of protection / Pollution degree
Insulation voltage
MTBF
Mounting position, installation notice
EMC / shock / vibration
Noise emission acc. to EN55022
Interference immunity test acc. to
mm²
mm²
Ordering data
Plastic clip-on foot
Metal clip-on foot
Type
CP M DM20
CP M DM20
Output
Screw connection
4 (3 +, 4 +, 3 -, 4 -)
0.5 / 6
0.5 / 2.5
26 / 12
Qty.
1
1
Order No.
1222210000
1222210010
Type
CP M DM40
CP M DM40
Output
Screw connection
4 (3 +, 4 +, 3 -, 4 -)
0.5 / 16
2.5 / 10
22 / 6
Qty.
1
1
Order No.
1222220000
1222220010
Note
Accessories
Note
2003670000
A.23
Switch-mode power supplies
connectPower PROmax
PRO-M: diode, capacity
and relay modules
CP M CAP
Pulse triggering for circuit breakers:
with the Weidmüller capacitance module
The following conditions apply to the table entries:
• Ambient temperature of 20 °C
• Inner resistance of the circuit breakers is taken into account
• Half of the rated current flows to a neighbouring circuit before the
short circuit is formed
• DC-compatible circuit breakers: Siemens 5SY series
+
11
12
14
12-
Distance in m
Technical data
Fuse tripping
Input
Rated input voltage / DC input voltage range
Output
Peak current output / Recovery time for the capacitor
Switching thresholds
24 V DC / 18…30 V DC
Depending on the load (typically 40 A for 1 ms) / Approx. 1 sec.
21.6 V DC, relay is on for Power Good, 20.4 V DC, relay is off for
Power Fail
Yes
Floating contact
General data
Depth x width x height / Weight
Ambient temperature (operational) / Storage temperature
Humidity
Protection degree
Class of protection
Pollution degree
Insulation voltage
MTBF
Mounting position, installation notice
150 / 34 / 130 mm / 0.4 kg
-25 °C...70 °C / -40 °C...85 °C
5...95 %, no condensation
IP 20
III, with no ground connection, for SELV
2
0.5 kV Input/output housing
> 500,000 h acc. to IEC 1709 (SN29500
Horizontal on TS35 mounting rail. 50 mm of clearance at top & bottom
for air circ. Can mount side by side with no space in between.
EMC / shock / vibration
Noise emission acc. to EN55022
Interference immunity test acc. to
Class B
EN 61000-4-2 (ESD)|EN 61000-4-3 and EN 61000-4-8 (fields)|EN
61000-4-4 (burst)|EN 61000-4-5 (surge)|EN 61000-4-6
(conducted)|EN 61000-4-11 (dips)
1 g according to EN50178 / 15 g In all directions
Resistance to vibration / Shock
Electrical safety (applied standards)
Electrical machine equipment
For use with electronic equipment
Safety extra-low voltage
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Load
1+
2+
Power supply
+
CAP module
A
Acc. to EN60204
Acc. to EN50178 / VDE0160
SELV acc. to EN60950, PELV acc. to EN60204
Conductor cross section
0.75 mm2
1.0 mm2
1.5 mm2
2.5 mm2
4 mm2
6 mm2
0.75 mm2
1.0 mm2
1.5 mm2
2.5 mm2
4 mm2
6 mm2
0.75 mm2
1.0 mm2
1.5 mm2
2.5 mm2
4 mm2
6 mm2
0.75 mm2
1.0 mm2
1.5 mm2
2.5 mm2
4 mm2
6 mm2
B6
10 m
14 m
20 m
30 m
50 m
B10
6 m
9 m
15 m
24 m
B16
4m
6m
10 m
16 m
C2
11 m
14 m
21 m
34 m
C6
3m
3.5 m
5.5 m
9m
14 m
C4
6 m
8 m
12 m
19 m
32 m
C10
2 m
3 m
5 m
8 m
12 m
CE; cULus; EAC; GL
mm²
mm²
Input
Screw connection
4 (++--)
0.5 / 6
0.5 / 4
26 / 12
Output
Screw connection
3 (CO contacts)
0.5 / 6
0.5 / 2.5
26 / 12
For low-impedance connections we recommend 2.5 mm².
Ordering data
Plastic clip-on foot
Metal clip-on foot
Type
CP M CAP
CP M CAP
Qty.
1
1
Order No.
1222240000
1222240010
Note
Accessories
Note
A.24
2003670000
A
2003670000
A.25
Switch-mode power supplies
Switch-mode power supplies
connectPower PROmax
A
PRO-M: Application solution for wind power
Switched-mode power supply with wide-range
input
Application solution for wind power:
• 80 ... 430 V DC input
• Alarm contact
• Metal snap-on foot
%
{
\u
Technical data
General technical data
Output characteristic curve / current limit
Earth discharge current
Ambient temperature (operational) / Storage temperature / Start-up
Max. permitted humidity (operational)
Degree of protection
Class of protection
Pollution degree
Insulation voltage
MTBF
Protection against reverse voltages from the load
Can be connected in parallel
Housing version
Signal indication
Mounting position, installation notice
Voltage derating
110
Pout [% Pn]
190
90
80
70
60
50
40
80
120
160
200
240
280
320
360
400
440
DC Input [V]
Temperature derating
130
120
EMC / shock / vibration
Noise emission acc. to EN55022
Noise immunity tests acc. to
Pout [% Pn]
110
100
90
80
70
60
20
30
40
50
60
Ambient temperature [°C]
A.26
70
80
Limiting of mains voltage harmonic currents
Resistance against vibration and shock
Electrical safety (applied standards)
Electrical equipment of machines
Safety transformers for switched-mode power units
Safety transformers for switched-mode power units
Safety extra low voltage
Protective separation / protection against electrical shock
Protection against dangerous shock currents
IU / > 120 % IR
< 3.5 mA
–25 °C…+70 °C / –40 °C…+85 °C / ≥ –40 °C
5 %…95 % RH
IP 20
I, with PE connection
2
3 kV AC 1 min. / 2 kV AC 1 min. / 0.5 kV AC 1 min.
> 500,000 h according to IEC 1709 (SN29500)
30…35 V DC
Yes, without diode module
Metal, corrosion resistant
Operations, green/red LED
Horizontal on TS 35 mounting rail, with 50 mm of clearance at top and
bottom for air circulation. Can be mounted side by side with no space in
between. Suitable for installation in rotating systems.
Class B
EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields),
EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted),
EN61000-4-11 (Dips)
according to EN61000-3-2
according to EN50178, Shock: 5 g in all directions
according to EN60204
according to EN61558-2-17
according to EN50178 / VDE0160
SELV according to EN60950, PELV according to EN60204
VDE0100-410 / according to DIN57100-410
according to VDE0106-101
2003670000
PRO-M: application solutions for
wind power
Switch-mode power supplies
connectPower PROmax
CP M SNT 250W 24V 10A UW
A
/
1²
$&
²
²
'&
3(
8
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Rated input voltage / Input voltage range AC
100...240 V AC (wide-range input) / 85…264 V AC (Derating @
100 V AC)
47...63 Hz
80…430 V DC
1.2 A @ 230 V AC / 2.4 A @ 115 V AC
0.8 A @ 370 V DC / 2.3 A @ 120 V DC
Yes
4 A / DI, safety fuse
10 A, Char. B, circuit breaker
3...4 A, Char. C, circuit breaker
Frequency range AC
DC input voltage range
AC current consumption
DC current consumption
Input fuse (internal)
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
General data
Degree of efficiency
Power factor (approx.)
AC failure bridging time @ INom
Depth x width x height / Weight
Additional equipment
Status indicator
Relay on/off
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Ordering data
Note
24 V DC ± 1 %
22.5...29.5 V DC (adjustable via potentiometer on front)
< 50 mVSS @ 24 V DC, IN, < 2,4 VSS @ 24 V DC, IN @ -40°C
10 A @ 60 °C
12 A @ 45 °C, 10.7 A @ 55 °C, 7.5 A @ 70 °C
90 % @ 230 V AC / 87 % @ 115 V AC
> 0.99 @ 230 V AC / > 0.97 @ 115 V AC
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC
155 / 60 / 130 mm / 1.2 Kg
Green LED, red LED
Output voltage > 21.6 V / < 20.4 V
CE; cULus; EAC; GL; GOSTME25; TUEV
mm²
mm²
Input
Screw connection
3 for L/N/PE
0.5 / 6
0.5 / 2.5
26 / 12
Type
CP M SNT 250W 24V 10AUW
Output
Screw connection
6 (+,+,-,-,COM,NO)
0.5 / 6
0.5 / 2.5
26 / 12
Qty.
1
Order No.
1165480010
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.27
Switch-mode power supplies
connectPower PROmax - Accessories
A
Small metal foot
Type
MTA 30 MF
Large metal foot
Order No.
1251320000
Small wall mounting
Type
CP A WALLADAPTER 30 MM
Small plastic foot
Type
MTA 45 MF
Order No.
1251310000
Order No.
1168970000
Type
MTA 45 BK
Order No.
1962250000
Large wall mounting
Order No.
1461870000
Type
CP A WALLADAPTER 45 MM
Order No.
1461850000
Large screwdriver
Small screwdriver
Type
SDIK PH1
SDIS 0.5X3.0X100
Type
MTA 30 BK
Large plastic foot
Blade type
Size/AF
1.00
B
a
b
0.5
3
c
80
100
Order No.
9008570000
9008380000
Type
SDIS 1.0X5.5X125
Blade type
B
Size/AF
a
1
b
5.5
c
125
Order No.
9008410000
Qty.
50
Order No.
1162600000
Endwinkel
Markers
For DIN rail TS 35
Type
SM 18/9.5 K MC NE WS
A.28
Colour
white
Qty.
200
Order No.
1248580000
Polyamide with fibre glass, screwable
WEW 35/1 SW
Colour
black
Torque
1.2 Nm
2003670000
A
2003670000
A.29
Switch-mode power supplies
Switch-mode power supplies
connectPower PRO-H
connectPower
PRO-H
A
% { \ | CB
Scheme
Technical data
L (+)
N (–)
AC
DC
PE
General technical data
Current limiting
Ambient temp. operating / storage temperature
Max. perm. air humidity (operation)
Degree of protection / Class of protection
Pollution degree
Insulation voltage input/output
MTBF according to IEC 61709
+
+
–
–
13
14
DC OK
Data
Link
> 100 % Irated
-25…+70 °C -25 °C…+85 °C
95 % RH
IP 20 / I, with PE connection
2
4 kV I/O
2 kV I/earth 0.5 kV O/earth
CP T … 70/90 W
> 1.8 Mio. h
CP T … 140 W
> 1.2 Mio. h
CP T … 180/360/600 W > 0.9 Mio. h
16 V DC / 35 V DC / 63 V DC
yes, without diode module
metal, corrosion resistant
Thermal protection, autom. restart
Unlimited, autom. restart
Dual LED Operational: Green LED; Error: Red LED
Horizontal on TS 35 mounting rail, with 80 mm space at top and bottom.
Side by side mounting with 50 mm clearance.
7 mm
Protection against reverse voltages from the load
Parallel connection option
Housing version
Overload protection
Short circuit protection
Indication
Mounting position, installation notice
Stripping length (rated connection)
Signal indication
Power Good Signal
Trigger point
12 V Version 9…11 V DC
24 V Version 18...22 V DC
48 V Version 36...44 V DC
NO contact
30 V DC / 1.0 A max. for 12/24 V DC modules
48 V DC/ 0.5 A max. for 36/48 V DC modules
70 W
11 V DC ± 1 V DC / 20 mA max.
140 W
11 V DC ± 1 V DC / 40 mA max.
90 W
22 V DC ± 2 V DC / 10 mA max.
180/360/600 W 24 V DC
22 V DC± 2 V DC / 20 mA max.
180/360/600 W 48 V DC
44 V DC± 4 V DC / 15 mA max.
Potential free, floating signal contact
Active output signal
Max. limiting average on state current [A]
Type\Temp.
1 ph 12 V / 6 A
1 ph 12 V / 12 A
1 ph 24 V / 3.8 A
1 ph 24 V / 7.5 A
1 ph 24 V / 15 A
1 ph 24 V / 25 A
1 ph 36 V / 16.5 A
1 ph 48 V / 2 A
1 ph 48 V / 4 A
1 ph 48 V / 7.5 A
1 ph 48 V / 12.5 A
1-2 ph 24 V / 7.5 A
1-2 ph 24 V / 15 A
1-2 ph 24 V / 25 A
40 °C
6.0
12.0
3.8
7.5
15.0
25.0
16.5
2.0
4.0
7.5
12.5
7.5
15.0
25.0
50 °C
5.7
9.5
3.1
6.3
12.5
22.5
15.0
1.6
3.3
6.3
11.3
6.3
12.5
22.5
60 °C
5.4
7.0
2.5
5.0
10.0
20.0
13.3
1.3
2.5
5.0
10.0
5.0
10.0
20.0
70 °C
4.5
3.7
1.7
3.3
6.7
13.3
9.0
0.8
1.7
3.3
7.5
3.3
6.7
13.3
EMC / shock / vibration
Noise emission acc. to EN55022
Noise immunity tests acc. to
Class B
EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields),
EN61000-4-4 (Burst), EN61000-4-5 (Surge),
EN610004-6 (conducted), EN61000-4-11 (Dips)
according to EN61000-3-2
3 axes, Sinus, 10…55 Hz, 1 g, 1 oct./min
3 axes, 15 g, half sinus, 11 ms
Limiting of mains voltage harmonic currents
Vibration IEC 60068-2-6
Shock IEC 60068-2-27
Electrical safety (applied standards)
Electrical equipment of machines
Safety transformers for switched-mode power units
Machinery with electronic equipment
Safety extra low voltage
according to EN60204
according to EN61558-2-4
according to EN50178
SELV according to EN60950
CP T SNT...
100
100
90
600 W
80
70
90 W
180 W
360 W
60
50
40
-25
40
50
Temperature [°C]
A.30
70 W
140 W
60
70
Output Power [% Pmax]
Output Power [% Pmax]
90
80
70
60
50
40
85 90 100 110 115
132
187
230 264
Input Voltage [V AC]
2003670000
connectPower
PRO-H
CP T SNT 70W 12V 6A
Switch-mode power supplies
connectPower PRO-H
CP T SNT 140W 12V 12A
A
L (+)
N (–)
+
–
AC
PE
DC
13
14
DC OK
Data
Link
L (+)
N (–)
+
+
–
–
AC
PE
DC
13
14
DC OK
Data
Link
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Ordering data
Note
mm²
mm²
100...240 V AC (wide-range input)
85...264 V AC
47...63 Hz
1 A @ 230 V AC, 2 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
1.4 A @ 230 V AC, 2.5 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
12 V DC ± 1 %
12...14 V DC (adjustable via potentiometer on front)
100 mVSS @ 12 V DC, Inom
6 A @ 40 °C
6 A @ 40 °C, 5.4 A @ 60 °C, 4.5 A @ 70 °C
12 V DC ± 1 %
12...14 V DC (adjustable via potentiometer on front)
100 mVSS @ 12 V DC, Inom
12 A @ 40 °C
12 A @ 40 °C, 7 A @ 60 °C, 3.7 A @ 70 °C
typ. 82 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 35 / 110 mm
0.5 kg
typ. 85 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 54 / 110 mm
0.7 kg
BVATEX; CE; CSA; cURus; EAC; UL
BVATEX; CE; CSA; cURus; EAC; UL
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
0.5 / 2.5
24 / 12
Type
CP T SNT 70W 12V 6A
Output
Screw connection
2 (+ / -)
1 / 2.5
1 / 2.5
18 / 12
Qty.
1
Order No.
1105430000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
0.5 / 2.5
24 / 12
Type
CP T SNT 140W 12V 12A
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
1 / 2.5
18 / 12
Qty.
1
Order No.
1105440000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.31
Switch-mode power supplies
connectPower PRO-H
connectPower
PRO-H
CP T SNT 90W 24V 3.8A
CP T SNT 90W 24V 3.8A CL2
Class 2, UL 1310
A
L (+)
N (–)
+
–
AC
PE
DC
13
14
DC OK
Data
Link
L (+)
N (–)
+
–
AC
PE
DC
13
14
DC OK
Data
Link
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Ordering data
Note
mm²
mm²
100...240 V AC (wide-range input)
85...264 V AC
47...63 Hz
1 A @ 230 V AC, 2.1 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
100...240 V AC (wide-range input)
85...264 V AC
47...63 Hz
1 A @ 230 V AC, 2.1 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
3.8 A @ 40 °C
3.8 A @ 40 °C, 2.5 A @ 60 °C, 1.7 A @ 70 °C
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
3.8 A @ 40 °C
3.8 A @ 40 °C, 2.5 A @ 60 °C, 1.7 A @ 70 °C
typ. 85 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 35 / 110 mm
0.5 kg
typ. 85 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 35 / 110 mm
0.5 kg
BVATEX; CE; CSA; cURus; EAC; UL
CE; EAC; UL
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
0.5 / 2.5
24 / 12
Type
CP T SNT 90W 24V 3,8A
Output
Screw connection
2 (+ / -)
1 / 2.5
0.5 / 2.5
24 / 12
Qty.
1
Order No.
1105790000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
0.5 / 2.5
24 / 12
Type
CP T SNT 90W 24V3,8ACL2
Output
Screw connection
2 (+ / -)
1 / 2.5
0.5 / 2.5
24 / 12
Qty.
1
Order No.
1194410000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Accessories
Note
A.32
2003670000
connectPower
PRO-H
CP T SNT 180W 24V 7.5A
Switch-mode power supplies
connectPower PRO-H
CP T SNT 360W 24V 15A
A
L (+)
N (–)
+
+
–
–
AC
PE
DC
13
14
DC OK
Data
Link
L (+)
N (–)
+
+
–
–
AC
PE
DC
13
14
DC OK
Data
Link
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Ordering data
Note
mm²
mm²
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
1.4 A @ 230 V AC, 2.5 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
2.5 A @ 230 V AC, 5 A @ 115 V AC
6.3 A / < 25 A (230 V AC)
10…16 A, char. B, circuit breaker
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
7.5 A @ 40 °C
7.5 A @ 40 °C, 5 A @ 60 °C, 3.3 A @ 70 °C
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
15 A @ 40 °C
15 A @ 40 °C, 10 A @ 60 °C, 6.7 A @ 70 °C
typ. 88 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 54 / 110 mm
0.7 kg
typ. 87 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 80 / 110 mm
1.1 kg
BVATEX; CE; CSA; cURus; EAC; UL
BVATEX; CE; CSA; cURus; EAC; UL
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
0.5 / 2.5
24 / 12
Type
CP T SNT 180W 24V 7,5A
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
0.5 / 2.5
24 / 12
Qty.
1
Order No.
1105810000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
0.5 / 2.5
24 / 12
Type
CP T SNT 360W 24V 15A
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
1 / 2.5
18 / 12
Qty.
1
Order No.
1105820000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.33
Switch-mode power supplies
connectPower PRO-H
connectPower
PRO-H
CP T SNT 600W 24V 25A
A
L (+)
N (–)
+
+
–
–
AC
PE
DC
13
14
DC OK
Data
Link
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Ordering data
Note
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
5 A @ 230 V AC, 10 A @ 115 V AC
12 A / < 30 A (230 V AC)
16…25 A, char. B, circuit breaker
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
25 A @ 40 °C
25 A @ 40 °C, 20 A @ 60 °C, 13.3 A @ 70 °C
typ. 89 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
125 / 165 / 125 mm
2.8 kg
BVATEX; CE; CSA; cURus; EAC; UL
mm²
mm²
Input
Screw connection
3 for L/N/PE
1/4
1/4
18 / 10
Type
CP T SNT 600W 24V 25A
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
2.5 / 4
12 / 10
Qty.
1
Order No.
1105840000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Accessories
Note
A.34
2003670000
connectPower
PRO-H
CP T SNT 90W 48V 2A
Switch-mode power supplies
connectPower PRO-H
CP T SNT 180W 48V 4A
A
L (+)
N (–)
PE
+
–
AC
DC
13
14
DC OK
Data
Link
L (+)
N (–)
+
+
–
–
AC
PE
DC
13
14
DC OK
Data
Link
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Ordering data
Note
mm²
mm²
100...240 V AC (wide-range input)
85...264 V AC
47...63 Hz
1 A @ 230 V AC, 2.1 A @ 115 V AC
4 A / < 20 A (230 V AC)
6…16 A, char. B, circuit breaker
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
1.4 A @ 230 V AC, 2.5 A @ 115 V AC
4 A / < 25 A (230 V AC)
6…16 A, char. B, circuit breaker
48 V DC ± 1 %
48...56 V DC (adjustable via potentiometer on front)
100 mVSS @ 48 V DC, INenn
2 A @ 40 °C
2 A @ 40 °C, 1.3 A @ 60 °C, 0.8 A @ 70 °C
48 V DC ± 1 %
48...56 V DC (adjustable via potentiometer on front)
100 mVSS @ 48 V DC, INenn
4 A @ 40 °C
4 A @ 40 °C, 2.5 A @ 60 °C, 1.7 A @ 70 °C
typ. 87 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 35 / 110 mm
0.5 kg
typ. 90 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
110 / 54 / 110 mm
0.7 kg
BVATEX; CE; EAC; UL
BVATEX; CE; CSA; cURus; EAC; UL
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
0.5 / 2.5
24 / 12
Type
CP T SNT 90W 48V 2A
Output
Screw connection
2 (+ / -)
1 / 2.5
0.5 / 2.5
24 / 12
Qty.
1
Order No.
1194420000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
0.5 / 2.5
24 / 12
Type
CP T SNT 180W 48V 4A
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
0.5 / 2.5
24 / 12
Qty.
1
Order No.
1105850000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.35
Switch-mode power supplies
connectPower PRO-H
connectPower
PRO-H
CP T SNT 360W 48V 7.5A
CP T SNT 600W 48V 12.5A
A
L (+)
N (–)
+
+
–
–
AC
PE
DC
13
14
DC OK
Data
Link
L (+)
N (–)
+
+
–
–
AC
PE
DC
13
14
DC OK
Data
Link
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Ordering data
Note
mm²
mm²
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
2.5 A @ 230 V AC, 5 A @ 115 V AC
6.3 A / < 25 A (230 V AC)
10…16 A, char. B, circuit breaker
100…240 V AC (auto-select)
85…132 V AC, 187…264 V AC
47...63 Hz
5 A @ 230 V AC, 10 A @ 115 V AC
12 A / < 30 A (230 V AC)
16…25 A, char. B, circuit breaker
48 V DC ± 1 %
48...56 V DC (adjustable via potentiometer on front)
100 mVSS @ 48 V DC, INenn
7.5 A @ 40 °C
7.5 A @ 40 °C, 5 A @ 60 °C, 3.3 A @ 70 °C
48 V DC ± 1 %
48...56 V DC (adjustable via potentiometer on front)
100 mVSS @ 48 V DC, INenn
12.5 A @ 40 °C
12.5 A @ 40 °C, 10 A @ 60 °C, 7.5 A @ 70 °C
typ. 89 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
125 / 80 / 125 mm
1.1 kg
typ. 91 % @ 230 V AC
min. 20 ms @ 230 V AC, min. 10 ms @ 115 V AC
yes, max. 5
125 / 165 / 125 mm
2.8 kg
BVATEX; CE; CSA; cURus; EAC; UL
BVATEX; CE; CSA; cURus; EAC; UL
Input
Screw connection
3 for L/N/PE
0.5 / 2.5
0.5 / 2.5
24 / 12
Type
CP T SNT 360W 48V 7,5A
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
1 / 2.5
18 / 12
Qty.
1
Order No.
1105860000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Input
Screw connection
3 for L/N/PE
1/4
1/4
18 / 10
Type
CP T SNT 600W 48V 12,5A
Output
Screw connection
7 (+ / - / Signal)
1 / 2.5
2.5 / 4
12 / 10
Qty.
1
Order No.
1105870000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Accessories
Note
A.36
2003670000
connectPower
PRO-H
CP T SNT2 180W 24V 7.5A
Switch-mode power supplies
connectPower PRO-H
CP T SNT2 360W 24V 15A
A
L (+)
N (–)
+
+
–
–
AC
PE
DC
13
14
DC OK
Data
Link
L (+)
N (–)
+
+
–
–
AC
PE
DC
13
14
DC OK
Data
Link
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Ordering data
Note
100…500 V AC (switchable)
85…132 V AC, 187…550 V AC
50 / 60 Hz
100…500 V AC (switchable)
85…132 V AC, 187…550 V AC
50 / 60 Hz
/ < 23 A @ 230 V AC
mm²
mm²
/ < 23 A @ 230 V AC
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
7.5 A @ 40 °C
7.5 A @ 40 °C, 5 A @ 60 °C, 3.3 A @ 70 °C
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
15 A @ 40 °C
15 A @ 40 °C, 6.7 A @ 70 °C, 10 A @ 60 °C
typ. 88 %
min. 20 ms
Yes
110 / 54 / 110 mm
0.7 kg
typ. 88 %
min. 20 ms
Yes
125 / 80 / 125 mm
1.1 kg
CE; EAC
CE; EAC
Input
Screw connection
3 for L/N/PE
1/4
1/4
18 / 10
Output
Screw connection
4 (++ / --)
2.5 / 4
2.5 / 4
12 / 10
Input
Screw connection
3 for L/N/PE
1/4
1/4
18 / 10
Output
Screw connection
4 (++ / --)
2.5 / 4
2.5 / 4
12 / 10
The device is suitable for single-phase and two-phase operation.
The device is suitable for single-phase and two-phase operation.
Type
CP T SNT2 180 W 24 V 7,5 A
Type
CP T SNT2 360 W 24 V 15 A
Qty.
1
Order No.
1194480000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Qty.
1
Order No.
1194490000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.37
Switch-mode power supplies
connectPower PRO-H
connectPower
PRO-H
CP T SNT2 600W 24V 25A
A
L (+)
N (–)
+
+
–
–
AC
PE
DC
13
14
DC OK
Data
Link
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Ordering data
Note
100…500 V AC (switchable)
85…132 V AC, 187…550 V AC
50 / 60 Hz
/ < 50 A @ 230 V AC
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
25 A @ 40 °C
25 A @ 40 °C, 20 A @ 40 °C, 13.3 A @ 70 °C
typ. 88 %
min. 20 ms
Yes
125 / 190 / 125 mm
3 kg
CE; EAC
mm²
mm²
Input
Screw connection
3 for L/N/PE
1/4
1/4
18 / 10
Output
Screw connection
5 (++ / ---)
2.5 / 4
2.5 / 4
12 / 10
The device is suitable for single-phase and two-phase operation.
Type
CP T SNT2 600 W 24 V 25 A
Qty.
1
Order No.
1194310000
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Accessories
Note
A.38
2003670000
connectPower
PRO-H
CP T RM 10
Switch-mode power supplies
connectPower PRO-H
CP T RM 20
A
Input 1
Data
Link PS1
Data
Link PS2
Input 1
Output
Control
Input 2
Remote
ON/OFF
Data
Link PS1
Data
Link PS2
Output
Control
Input 2
DC OK
Remote
ON/OFF
DC OK
Technical data
Input
Rated input voltage
Input voltage range AC
Frequency range AC
AC current consumption
Input fuse (internal) / Inrush current
Recommended back-up fuse
Output
Rated output voltage
Output voltage
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
General data
Degree of efficiency
AC failure bridging time @ INom
Parallel connection option
Depth x width x height
Weight
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Ordering data
mm²
mm²
24 V DC
24 V DC
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
15 A @ 40 °C
24 V DC ± 1 %
24...28 V DC (adjustable via potentiometer on front)
100 mVPP @ 24 V DC, Inenn
25 A @ 40 °C
110 / 35 / 110 mm
0.4 kg
110 / 54 / 110 mm
0.45 kg
CE; CSA; cURus; EAC; GOSTME25
CE; CSA; cURus; EAC; GOSTME25
Input
Output
Input
Output
4 (++--)
1/4
1/4
18 / 10
4 (++ / --)
2.5 / 4
2.5 / 4
12 / 10
4 (++--)
1/4
1/4
18 / 10
4 (++ / --)
2.5 / 4
2.5 / 4
12 / 10
Type
CP T RM 10
Qty.
1
Order No.
1105880000
Type
CP T RM 20
Qty.
1
Order No.
1105890000
Note
Accessories
Note
2003670000
A.39
Switch-mode power supplies
connectPower PRO H - Accessories
A
Large screwdriver
Small screwdriver
Type
SDIK PH1
SDIS 0.5X3.0X100
Blade type
Size/AF
1.00
B
a
b
0.5
3
c
80
100
Order No.
9008570000
9008380000
Type
SDIK PH2
SDIS 1.0X5.5X125
Blade type
Size/AF
2.00
B
a
b
1
5.5
c
100
125
Order No.
9008580000
9008410000
Qty.
50
Order No.
1162600000
End bracket
Markers
For DIN rail TS 35
Type
SM 18/9.5 K MC NE WS
A.40
Colour
white
Qty.
200
Order No.
1248580000
Polyamide with fibre glass, screwable
WEW 35/1 SW
Colour
black
Torque
1.2 Nm
2003670000
PRO-H Dimensional drawings
CP T RM 10
CP T RM 20
35.0 (1.38)
DC 24 V / 25 A
Inputs ON
- + - +
25.0
110.0
DC IN 1
5.0
(0.20)
(0.98)
5.0
CP T SNT 70 W / 90 W
DC IN 2
25.0
(0.20)
5.0
(0.20)
80.0 (3.15)
DC IN 1 DC IN 2
14.5
(0.57)
CP T SNT 180 W / 140 W
110.0
54.0
(4.33)
110.0 (4.33)
(2.13)
38.5
(1.52)
(1.38)
DC OK
DC ON
A
24 ² 27 V
80.0
(3.15)
110.0
(4.33)
(4.33)
24 ² 27 V
38.5 (1.52)
Output
Inputs ON
(0.98)
110.0 (4.33)
(2.13)
38.5 (1.52)
38.5
- - + +
35.0
54.0
(4.33)
(1.52)
110.0
Switch-mode power supplies
connectPower PRO-H
DC ON
DC OK
O/P ADJ .
5.0
(0.20)
5.0
(0.20)
L
25.0
(0.98)
14.5
(0.57)
S P
25.0
(0.98)
PE N
L
5.0
N
(0.20)
PE
80.0 (3.15)
110.0
80.0
(3.15)
110.0
(4.33)
(4.33)
O/P ADJ .
P/ S
P S
Remote
P/ S
Remote
2003670000
A.41
CP T SNT 360 W / 480 W
CP T SNT 600 W / 960 W
80.0 (3.15)
125.0
(4.92)
P/ S Remote
45.0 (1.77)
P S
DC OK
DC ON
O/P ADJ .
86.5 (3.41)
A
PRO-H Dimensional drawings
125.0 (4.92)
Switch-mode power supplies
connectPower PRO-H
25.0
25.0
(0.98)
PE N
(0.98)
21.0
123.0
L
(4.84)
(0.83)
165.0 (6.50)
45.0 (1.77)
(0.98)
17.0
(0.67)
25.0
(0.98)
125.0 (4.92)
5.0
(0.20)
(1.81)
PE N
L
DC OK
DC ON
O/P A DJ.
86.5 (3.41)
46.0
25.0
125.0 (4.92)
Remote
P S
P/ S
A.42
2003670000
A
2003670000
A.43
Switch-mode power supplies
Switch-mode power supplies
connectPower PRO-E
connectPower
PRO-E
CP E SNT 25W 5V 5A
CP E SNT 25W 12V 2.1A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
85...264 V AC / 110…370 V DC
0.3 A @ 230 V AC / 0.6 A @ 120 V AC
47...63 Hz
yes / max. 20A
1 A at 230 V AC, characteristic curve C
85...264 V AC / 110…370 V DC
0.3 A @ 230 V AC / 0.6 A @ 120 V AC
47...63 Hz
yes / max. 20A
1 A at 230 V AC, characteristic curve C
5 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
5 A@5 V DC
25 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
5.6...6.8 V @ 5 V DC
20 ms
0.5%
Recommended with diode module
12 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
2.1 A@12 V DC
25 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
13.5...16.2 V @ 12 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
77 % @ 5 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
240 g
CE; cURus; EAC
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
79 % @ 12 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
240 g
CE; cURus; EAC
0.34 / 4 mm²
91 / 51 / 28 mm
0.34 / 4 mm²
91 / 51 / 28 mm
Note
Ordering data
Note
Type
CP E SNT 25W 5V 5A
Qty.
1
Order No.
1202640000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Type
CP E SNT 25W 12V 2.1A
Qty.
1
Order No.
1202630000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
A.44
2003670000
connectPower
PRO-E
CP E SNT 25W 24V 1.1A
Switch-mode power supplies
connectPower PRO-E
CP E SNT 25W 48V 0.57A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
85...264 V AC / 110…370 V DC
0.3 A @ 230 V AC / 0.6 A @ 120 V AC
47...63 Hz
yes / max. 20A
1 A at 230 V AC, characteristic curve C
85...264 V AC / 110…370 V DC
0.3 A @ 230 V AC / 0.6 A @ 120 V AC
47...63 Hz
yes / max. 20A
1 A at 230 V AC, characteristic curve C
24 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
1.1 A@24 V DC
25 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
28...32 V @ 24 V DC
20 ms
0.5%
Recommended with diode module
48 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
0.57 A@48 V DC
25 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
55...62 V @ 48 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
84 % @ 24 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
240 g
CE; cURus; EAC
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
83 % @ 48 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
240 g
CE; cURus; EAC
0.34 / 4 mm²
91 / 51 / 28 mm
0.34 / 4 mm²
91 / 51 / 28 mm
Note
Ordering data
Note
Type
CP E SNT 25W 24V 1.1A
Qty.
1
Order No.
1202620000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Type
CP E SNT 25W 48V 0.57A
Qty.
1
Order No.
1202610000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.45
Switch-mode power supplies
connectPower PRO-E
connectPower
PRO-E
CP E SNT 50W 5V 10A
CP E SNT 50 W 12V 4.2A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
85...264 V AC / 110…370 V DC
0.6 A @ 230 V AC / 1.2 A @ 120 V AC
47...63 Hz
yes / max. 20A
2 A at 230 V AC, characteristic curve C
85...264 V AC / 110…370 V DC
0.6 A @ 230 V AC / 1.2 A @ 120 V AC
47...63 Hz
yes / max. 20A
2 A at 230 V AC, characteristic curve C
5 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
10 A@5 V DC
50 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
5.6...6.8 V @ 5 V DC
20 ms
0.5%
Recommended with diode module
12 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
4.2 A@12 V DC
50 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
13.5...16.2 V @ 12 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
78 % @ 5 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
310 g
CE; cURus; EAC
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
81 % @ 12 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
310 g
CE; cURus; EAC
0.34 / 4 mm²
105 / 100 / 35 mm
0.34 / 4 mm²
105 / 100 / 35 mm
Note
Ordering data
Note
Type
CP E SNT 50W 5V 10A
Qty.
1
Order No.
1202590000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Type
CP E SNT 50W 12V 4.2A
Qty.
1
Order No.
1202580000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
A.46
2003670000
connectPower
PRO-E
CP E SNT 50W 24V 2.2A
Switch-mode power supplies
connectPower PRO-E
CP E SNT 50W 48V 1.1A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
85...264 V AC / 110…370 V DC
0.6 A @ 230 V AC / 1.2 A @ 120 V AC
47...63 Hz
yes / max. 20A
2 A at 230 V AC, characteristic curve C
85...264 V AC / 110…370 V DC
0.6 A @ 230 V AC / 1.2 A @ 120 V AC
47...63 Hz
yes / max. 20A
2 A at 230 V AC, characteristic curve C
24 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
2.2 A@24 V DC
50 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
28...32 V @ 24 V DC
20 ms
0.5%
Recommended with diode module
48 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
1.1 A@48 V DC
50 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
55...62 V @ 48 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
84 % @ 24 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
310 g
CE; cURus; EAC
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
86 % @ 48 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
310 g
CE; cURus; EAC
0.34 / 4 mm²
105 / 100 / 35 mm
0.34 / 4 mm²
105 / 100 / 35 mm
Note
Ordering data
Note
Type
CP E SNT 50W 24V 2.2A
Qty.
1
Order No.
1202450000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Type
CP E SNT 50W 48V 1.1A
Qty.
1
Order No.
1202460000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.47
Switch-mode power supplies
connectPower PRO-E
connectPower
PRO-E
CP E SNT 75W 5V 12A
CP E SNT 75W 12V 6A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
85...264 V AC / 110…370 V DC
1 A @ 230 V AC / 2 A @ 120 V AC
47...63 Hz
yes / max. 20A
4 A at 230 V AC, characteristic curve C
85...264 V AC / 110…370 V DC
1 A @ 230 V AC / 2 A @ 120 V AC
47...63 Hz
yes / max. 20A
4 A at 230 V AC, characteristic curve C
5 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
12 A@5 V DC
75 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
5.6...6.8 V @ 5 V DC
20 ms
0.5%
Recommended with diode module
12 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
6 A@12 V DC
75 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
13.5...16.2 V @ 12 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
76 % @ 5 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
440 g
CE; cURus; EAC
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
81 % @ 12 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
440 g
CE; cURus; EAC
0.34 / 4 mm²
135 / 98.5 / 40 mm
0.34 / 4 mm²
135 / 98.5 / 40 mm
Note
Ordering data
Note
Type
CP E SNT 75W 5V 12A
Qty.
1
Order No.
1202470000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Type
CP E SNT 75W 12V 6A
Qty.
1
Order No.
1202480000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
A.48
2003670000
connectPower
PRO-E
CP E SNT 75W 24V 3.2A
Switch-mode power supplies
connectPower PRO-E
CP E SNT 75W 48V 1.6A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
85...264 V AC / 110…370 V DC
1 A @ 230 V AC / 2 A @ 120 V AC
47...63 Hz
yes / max. 20A
4 A at 230 V AC, characteristic curve C
85...264 V AC / 110…370 V DC
1 A @ 230 V AC / 2 A @ 120 V AC
47...63 Hz
yes / max. 20A
4 A at 230 V AC, characteristic curve C
24 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
3.2 A@24 V DC
75 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
28...32 V @ 24 V DC
20 ms
0.5%
Recommended with diode module
48 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
1.6 A@48 V DC
75 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
55...62 V @ 48 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
85 % @ 24 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
440 g
CE; cURus; EAC
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
86 % @ 48 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
440 g
CE; cURus; EAC
0.34 / 4 mm²
135 / 98.5 / 40 mm
0.34 / 4 mm²
135 / 98.5 / 40 mm
Note
Ordering data
Note
Type
CP E SNT 75W 24V 3.2A
Qty.
1
Order No.
1202490000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Type
CP E SNT 75W 48V 1.6A
Qty.
1
Order No.
1202510000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.49
Switch-mode power supplies
connectPower PRO-E
connectPower
PRO-E
CP E SNT 100W 5V 16A
CP E SNT 100W 12V 8.5A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
88…132 V AC / 176…264 V AC optional / 250...370 V DC
1.5 A @ 230 V AC / 3 A @ 120 V AC
47...63 Hz
yes / max. 20A
4 A at 230 V AC, characteristic curve C
88…132 V AC / 176…264 V AC optional / 250...370 V DC
1.5 A @ 230 V AC / 3 A @ 120 V AC
47...63 Hz
yes / max. 20A
4 A at 230 V AC, characteristic curve C
5 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
16 A@5 V DC
100 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
5.6...6.8 V @ 5 V DC
20 ms
0.5%
Recommended with diode module
12 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
8.5 A@12 V DC
100 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
13.5...16.2 V @ 12 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
77 % @ 5 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
590 g
CE; cURus; EAC
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
81 % @ 12 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
590 g
CE; cURus; EAC
0.34 / 4 mm²
164 / 97.5 / 40 mm
0.34 / 4 mm²
164 / 97.5 / 40 mm
Note
Ordering data
Note
Type
CP E SNT 100W 5V 16A
Qty.
1
Order No.
1165820000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Type
CP E SNT 100W 12V 8.5A
Qty.
1
Order No.
1165830000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
A.50
2003670000
connectPower
PRO-E
CP E SNT 100W 24V 4.5A
Switch-mode power supplies
connectPower PRO-E
CP E SNT 100W 48V 2.3A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
88…132 V AC / 176…264 V AC optional / 250...370 V DC
1.5 A @ 230 V AC / 3 A @ 120 V AC
47...63 Hz
yes / max. 20A
4 A at 230 V AC, characteristic curve C
88…132 V AC / 176…264 V AC optional / 250...370 V DC
1.5 A @ 230 V AC / 3 A @ 120 V AC
47...63 Hz
yes / max. 20A
4 A at 230 V AC, characteristic curve C
24 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
4.5 A@24 V DC
100 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
28...32 V @ 24 V DC
20 ms
0.5%
Recommended with diode module
48 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
2.3 A@48 V DC
100 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
55...62 V @ 48 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
85 % @ 24 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
590 g
CE; cURus; EAC
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
86 % @ 48 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
590 g
CE; cURus; EAC
0.34 / 4 mm²
164 / 97.5 / 40 mm
0.34 / 4 mm²
164 / 97.5 / 40 mm
Note
Ordering data
Note
Type
CP E SNT 100W 24V 4.5A
Qty.
1
Order No.
1165840000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Type
CP E SNT 100W 48V 2.3A
Qty.
1
Order No.
1165850000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.51
Switch-mode power supplies
connectPower PRO-E
connectPower
PRO-E
CP E SNT 150W 12V 12.5A
CP E SNT 150W 24V 6.5A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
88…132 V AC / 176…264 V AC optional / 250...370 V DC
2 A @ 230 V AC / 3.5 A @ 120 V AC
47...63 Hz
yes / max. 35A
4 A at 230 V AC, characteristic curve C
88…132 V AC / 176…264 V AC optional / 250...370 V DC
2 A @ 230 V AC / 3.5 A @ 120 V AC
47...63 Hz
yes / max. 35A
4 A at 230 V AC, characteristic curve C
12 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
12.5 A@12 V DC
150 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
13.5...16.2 V @ 12 V DC
20 ms
0.5%
Recommended with diode module
24 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
6.5 A@24 V DC
150 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
28...32 V @ 24 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
82 % @ 12 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
820 g
CE; cURus; EAC
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
86 % @ 24 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
820 g
CE; cURus; EAC
0.34 / 4 mm²
205 / 99 / 40 mm
0.34 / 4 mm²
205 / 99 / 40 mm
Note
Ordering data
Note
Type
CP E SNT 150W 12V 12.5A
Qty.
1
Order No.
1165870000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Type
CP E SNT 150W 24V 6.5A
Qty.
1
Order No.
1165880000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
A.52
2003670000
connectPower
PRO-E
Switch-mode power supplies
connectPower PRO-E
CP E SNT 150W 48V 3.3A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
88…132 V AC / 176…264 V AC optional / 250...370 V DC
2 A @ 230 V AC / 3.5 A @ 120 V AC
47...63 Hz
yes / max. 35A
4 A at 230 V AC, characteristic curve C
48 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
3.3 A@48 V DC
150 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
55...62 V @ 48 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
87 % @ 48 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
820 g
CE; cURus; EAC
0.34 / 4 mm²
205 / 99 / 40 mm
Note
Ordering data
Note
Type
CP E SNT 150W 48V 3.3A
Qty.
1
Order No.
1165890000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.53
Switch-mode power supplies
connectPower PRO-E
connectPower
PRO-E
CP E SNT 250W 12V 21A
CP E SNT 250W 24V 10.5A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
88…132 V AC / 176…264 V AC optional / 250...370 V DC
2.5 A @ 230 V AC / 4.7 A @ 120 V AC
47...63 Hz
yes / max. 35A
6 A at 230 V AC, characteristic curve C
88…132 V AC / 176…264 V AC optional / 250...370 V DC
2.5 A @ 230 V AC / 4.7 A @ 120 V AC
47...63 Hz
yes / max. 35A
6 A at 230 V AC, characteristic curve C
12 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
21 A@12 V DC
250 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
13.5...16.2 V @ 12 V DC
20 ms
0.5%
Recommended with diode module
24 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
10.5 A @ 24 V DC
250 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
28...32 V @ 24 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
80 % @ 12 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
1080 g
CE; cURus; EAC
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
81 % @ 24 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
1080 g
CE; cURus; EAC
0.34 / 4 mm²
231 / 115 / 49.5 mm
0.34 / 4 mm²
231 / 115 / 49.5 mm
Note
Ordering data
Note
Type
CP E SNT 250W 12V 21A
Qty.
1
Order No.
1202520000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Type
CP E SNT 250W 24V 10.5A
Qty.
1
Order No.
1202530000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
A.54
2003670000
connectPower
PRO-E
Switch-mode power supplies
connectPower PRO-E
CP E SNT 250W 48V 5.2A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
88…132 V AC / 176…264 V AC optional / 250...370 V DC
2.5 A @ 230 V AC / 4.7 A @ 120 V AC
47...63 Hz
yes / max. 35A
6 A at 230 V AC, characteristic curve C
48 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
5.2 A@48 V DC
250 W
< 100 mVPP
120~150% Ikonst. of max. output power, automatic restart
55...62 V @ 48 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
83 % @ 48 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
1080 g
CE; cURus; EAC
0.34 / 4 mm²
231 / 115 / 49.5 mm
Note
Ordering data
Note
Type
CP E SNT 250W 48V 5.2A
Qty.
1
Order No.
1202540000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.55
Switch-mode power supplies
connectPower PRO-E
connectPower
PRO-E
CP E SNT 350W 24V 14.6A
CP E SNT 350W 48V 7.3A
A
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
/
1²
$&
3(
'&
²
1RWHSRODULW\IRU'&FRQQHFWLRQ
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse (internal)
Recommended back-up fuse
Output
Output voltage
Output voltage adjustment
Output current
Output power
Residual ripple, breaking spikes
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
General data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity (operational)
Degree of efficiency
Status indicator
Standards
EMC standards
Mounting position, installation notice
Weight
Approvals
Screw connection
Connection cross-section, solid, min. / max.
Depth x width x height
85...264 V AC / 110…370 V DC
3 A @ 230 V AC / 5.6 A @ 120 V AC
47...63 Hz
yes / max. 35A
6 A at 230 V AC, characteristic curve C
85...264 V AC / 110…370 V DC
3 A @ 230 V AC / 5.6 A @ 120 V AC
47...63 Hz
yes / max. 35A
6 A at 230 V AC, characteristic curve C
24 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
14.6 A@24 V DC
350 W
48 V DC
± 10% nominal output voltage tolerance, adjustable with
potentiometer
7.3 A@48 V DC
350 W
120~150% Ikonst. of max. output power, automatic restart
28...32 V @ 24 V DC
20 ms
0.5%
Recommended with diode module
120~150% Ikonst. of max. output power, automatic restart
55...62 V @ 48 V DC
20 ms
0.5%
Recommended with diode module
0.5 kV
1.5 kV
3 kV
0.5 kV
1.5 kV
3 kV
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
83 % @ 24 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
1250 g
CE; cURus; EAC
-20°C…70°C (>50°C derating,refer derated curve); 70% rated
load@70°C
-20 °C...85 °C
5 %…95 % RH
85 % @ 48 V DC
Operation, green LED
EN 60950
EN 55011, EN 55022, EN 55024, EN 61000-6 /-2, -3
Panel mount, screw fix
1250 g
CE; cURus; EAC
0.34 / 4 mm²
230 / 115 / 49.5 mm
0.34 / 4 mm²
230 / 115 / 49.5 mm
Note
Ordering data
Note
Type
CP E SNT 350W 24V 14.6A
Qty.
1
Order No.
1202550000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Type
CP E SNT 350W 48V 7.3A
Qty.
1
Order No.
1202560000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
A.56
2003670000
A
2003670000
A.57
Switch-mode power supplies
Installation drawing
CP E SNT 25W
CP E SNT 50W
78
55
11
105
99.5
6.5
Ø 3.5
52.5
32
93
100
A
34
25.5
2-M3
2-M3
3
Ø4
Ø 3.5
3.25
Ø 3.5
3.25
14
30
28
66
12 12
15 13.5
35
Switch-mode power supplies
connectPower PRO-E
15
93
100
2-M3
CP E SNT 75W
3-M3
CP E SNT 100W
135
124.5
78
4.4
Ø 3.5
164
57
6
6.5
52
32
90.5
97.5
32
91.5
98.5
32.5
34
Ø 3.5
2-M3
2.25
Ø 3.5
Ø 3.5
2.25
117
152.5
3-M3
3.25
Ø 3.5
18
28.5
40
31
19.8
3-M3
28.4
18.6
22
Ø 3.5
4-M3
11 18
29.5
40
Ø 3.5
2.75
20
10
Ø 3.5
124.5
78
120
18.5
80.5
92
99
6.5
205
195.5
9.25
CP E SNT 150W
Ø 3.5
Ø 3.5
4-M3
18.5
31
40
157
205
A.58
4.75
3.5
157
193
20.5
11
28
18
Ø 3.5
3-M3
2003670000
Switch-mode power supplies
connectPower PRO-E
Installation drawing
CP E SNT 250W and CP E SNT 350W
150
32.5
230
25
49.5
20
12.5
5-M3
CP E SNT 250W and CP E SNT 350W (with mounting clip)
57
150
230
150.5
32.5
32.5
26
14
26
150
4.5
3-Ø
26
32.5
8
15
Ø4
.5
115
A
15
8
50
115
5-M3
150
14
26
32.5
150
26
3-Ø4.514
8
15
15
8
26
49.5
26
Ø4.5
230
Ø4.5
115
131
145
32.5
115
118
12.5
32
145
131
25
Ø4.5
6-M3
4.5
3-Ø
49.5
68
.5
Ø4
230
25
14
26
CP-E-SNT derating curve / ambient temperature
CP E SNT 25W up to CP E SNT 350W
100%
Load (%)
80%
60%
40%
20%
0
10
20
30
40
50
60
70
80
Ambient temperature (°C)
2003670000
A.59
Switch-mode power supplies
connectPower INSTAPOWER
connectPower
Single-phase
CP SNT 24W 24V 1A
CP SNT 24W 15V 1.5A
A
L
AC/DC
N
PWM
L
+
FUSE
N
DC
+
L
−
N
FUSE
+
−
–
Technical data
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Parallel connection option
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
Note
85...265 V AC, 120...300 V DC
460 mA @ 115 V AC; 250 mA @ 230 V AC
50/ 60 Hz
Thermistor
2 A time-lag fuse (internal)
Varistor
85...265 V AC, 120...300 V DC
460 mA @ 115 V AC; 250 mA @ 230 V AC
50/ 60 Hz
Thermistor
2 A time-lag fuse (internal)
Varistor
24 V DC
1A
24 W
<2%
Surge current / thermal cut-out
Varistor
35 ms @ 115 V AC / 160 ms @ 230 V AC
0.5%
8000 µF
15 V DC
1.5 A
22.5 W
<2%
Surge current / thermal cut-out
Varistor
35 ms @ 115 V AC / 160 ms @ 230 V AC
0.5%
8000 µF
0.5 kV
1.5 kV
3 kV
4 kV
0.5 kV
1.5 kV
3 kV
4 kV
-20 °C...50 °C
-40 °C...85 °C
78%
DIN EN 50178, DIN EN 60950, IEC950
CE; CSA; CSAEX; cULus; EAC; GOSTME25
EN 61000-6 /-2, -3
yes, max 2.
-20 °C...50 °C
-40 °C...85 °C
78%
DIN EN 50178, DIN EN 60950, IEC950
CE; CSA; cULus; EAC; GOSTME25
EN 61000-6 /-2, -3
yes, max 2.
Input/Output
4 / 0.08 / 4
62.5 / 52 / 90.5
Input/Output
4 / 0.08 / 4
62.5 / 52 / 90.5
Derating loss: 33 % @ 60 °C The internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Derating loss: 33 % @ 60 °C The internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Type
CP SNT 24W 24V 1A
Type
CP SNT 24W 15V 1.5A
Qty.
1
Order No.
9928890024
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Qty.
1
Order No.
9928890015
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
A.60
2003670000
connectPower
Single-phase
CP SNT 24W 12V 1.5A
Switch-mode power supplies
connectPower INSTAPOWER
CP SNT 24W 5V 2A
A
L
AC/DC
N
PWM
L
+
FUSE
N
DC
+
L
−
N
FUSE
+
−
–
Technical data
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Parallel connection option
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
Note
85...265 V AC, 120...300 V DC
460 mA @ 115 V AC; 250 mA @ 230 V AC
50/ 60 Hz
Thermistor
2 A time-lag fuse (internal)
Varistor
85...265 V AC, 120...300 V DC
460 mA @ 115 V AC; 250 mA @ 230 V AC
50/ 60 Hz
Thermistor
2 A time-lag fuse (internal)
Varistor
12 V DC
1.5 A
18 W
<2%
Surge current / thermal cut-out
Varistor
35 ms @ 115 V AC / 160 ms @ 230 V AC
0.5%
8000 µF
5 V DC
2A
10 W
<2%
Surge current / thermal cut-out
Varistor
35 ms @ 115 V AC / 160 ms @ 230 V AC
0.5%
8000 µF
0.5 kV
1.5 kV
3 kV
4 kV
0.5 kV
1.5 kV
3 kV
4 kV
-20 °C...50 °C
-40 °C...85 °C
78%
DIN EN 50178, DIN EN 60950, IEC950
CE; CSA; cULus; EAC; GOSTME25
EN 61000-6 /-2, -3
yes, max 2.
-20 °C...50 °C
-40 °C...85 °C
78%
DIN EN 50178, DIN EN 60950, IEC950
CE; CSA; cULus; EAC; GOSTME25
EN 61000-6 /-2, -3
yes, max 2.
Input/Output
4 / 0.08 / 4
62.5 / 52 / 90.5
Input/Output
4 / 0.08 / 4
62.5 / 52 / 90.5
Derating loss: 33 % @ 60 °C The internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Derating loss: 33 % @ 60 °C The internal varistor found in a switch-mode power
supply does not replace the need for surge protection within a system.
Type
CP SNT 24W 12V 1.5A
Type
CP SNT 24W 5V 2A
Qty.
1
Order No.
9928890012
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Qty.
1
Order No.
9928890005
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.61
Switch-mode power supplies
connectPower INSTAPOWER
connectPower
Single-phase
CP SNT 25W 5V 5A
A
PWM
L
+
FUSE
+
−
N
DC
–
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
85...264 V AC / 110...370 V DC
500 mA at rated load @ 230 V AC
50/ 60 Hz
Yes
Fusible link 2.5 A (T) / 250 V
5
4...8 V DC (adjustable via potentiometer)
5A
25 W
120 mVSS
105 %...150 % Iconst of max. output load; automatic reset
4
3
2
1
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
Varistor
11 ms @ 115 V AC / 50 ms @ 230 V AC
1%
10000 µF
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Parallel connection option
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
6
Current (A)
L
AC/DC
N
0.5 kV
1.5 kV
3 kV
4 kV
-10...70 °C (Derating ab 55 °C)
-20 °C...85 °C
70%
DIN EN 50178 (PELV), DIN EN 60950 (SELV)
cCSAus; cURus; EAC; GOSTME25; UL
EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4
Max. 3 devices (rated voltages are to be calibrated at ±20 mV)
mm²
mm
Input/Output
2.5 / 0.5 / 4
62.5 / 70 / 90.5
Note
Ordering data
Screw connection
Note
Type
CP SNT 25W 5V 5A
Qty.
1
Order No.
8754960000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
A.62
2003670000
connectPower
Single-phase
Switch-mode power supplies
connectPower INSTAPOWER
CP SNT 48W 12V 4A
A
PWM
L
+
FUSE
+
−
N
DC
–
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
85...264 V AC / 110...370 V DC
500 mA at rated load @ 230 V AC
50/ 60 Hz
Yes
Fusible link 2.5 A (T) / 250 V
5
9...15 V DC (adjustable via potentiometer)
4A
48 W
120 mVSS
105 %...150 % Iconst of max. output load; automatic reset
4
3
2
1
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
Varistor
11 ms @ 115 V AC / 50 ms @ 230 V AC
1%
10000 µF
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Parallel connection option
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
6
Current (A)
L
AC/DC
N
0.5 kV
1.5 kV
3 kV
4 kV
-10...70 °C (Derating ab 55 °C)
-20 °C...85 °C
75%
DIN EN 50178 (PELV), DIN EN 60950 (SELV)
cCSAus; CE; cURus; EAC; GOSTME25; UL
EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4
Max. 3 devices (rated voltages are to be calibrated at ±20 mV)
mm²
mm
Input/Output
2.5 / 0.5 / 4
62.5 / 70 / 90.5
Note
Ordering data
Screw connection
Note
Type
CP SNT 48W 12V 4A
Qty.
1
Order No.
8754970000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.63
Switch-mode power supplies
connectPower INSTAPOWER
connectPower
Single-phase
CP SNT 48W 24V 2A
A
PWM
L
+
FUSE
+
−
N
DC
–
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
85...264 V AC / 110...370 V DC
500 mA at rated load @ 230 V AC
50/ 60 Hz
Yes
Fusible link 2.5 A (T) / 250 V
15...28 V DC (adjustable via potentiometer)
2A
48 W
120 mVSS
105 %...150 % Iconst of max. output load; automatic reset
2
1.5
1
0.5
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
Varistor
11 ms @ 115 V AC / 50 ms @ 230 V AC
1%
10000 µF
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Parallel connection option
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
3
2.5
Current (A)
L
AC/DC
N
0.5 kV
1.5 kV
3 kV
4 kV
-10...70 °C (Derating ab 55 °C)
-20 °C...85 °C
78%
DIN EN 50178 (PELV), DIN EN 60950 (SELV)
cCSAus; cURus; EAC; GOSTME25; UL
EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4
Max. 3 devices (rated voltages are to be calibrated at ±20 mV)
mm²
mm
Input/Output
2.5 / 0.5 / 4
62.5 / 70 / 90.5
Note
Ordering data
Screw connection
Note
Type
CP SNT 48W 24V 2A
Qty.
1
Order No.
8739140000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
A.64
2003670000
connectPower
Single-phase
Switch-mode power supplies
connectPower INSTAPOWER
CP SNT 48W 48V 1A
A
PWM
L
+
FUSE
+
−
N
DC
–
Technical data
Derating curve
Input
Input voltage
Input current
Input frequency
Turn-on current limit
Input fuse
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
85...264 V AC / 110...370 V DC
500 mA at rated load @ 230 V AC
50/ 60 Hz
Yes
Fusible link 2.5 A (T) / 250 V
46...55 V DC (adjustable via potentiometer)
1A
48 W
120 mVSS
105 %...150 % Iconst of max. output load; automatic reset
1.5
1
0.5
0
0
10
20 30 40 50 60
Ambient temperature (°C)
70
80
Varistor
11 ms @ 115 V AC / 50 ms @ 230 V AC
1%
10000 µF
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Max. capacitance at output
Insulation coordination (EN 50178)
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Standards
Approvals
EMC standards
Parallel connection option
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
2
Current (A)
L
AC/DC
N
0.5 kV
1.5 kV
3 kV
4 kV
-10...70 °C (Derating ab 55 °C)
-20 °C...85 °C
80%
DIN EN 50178 (PELV), DIN EN 60950 (SELV)
cCSAus; cURus; EAC; GOSTME25; UL
EN 55011, EN 55022, EN 61000-3-2,-3, EN 61000-6-2,-3,-4
Max. 3 devices (rated voltages are to be calibrated at ±20 mV)
mm²
mm
Input/Output
2.5 / 0.5 / 4
62.5 / 70 / 90.5
Note
Ordering data
Screw connection
Note
Type
CP SNT 48W 48V 1A
Qty.
1
Order No.
8879230000
The internal varistor found in a switch-mode power supply does not replace the
necessary surge protection in a system.
Accessories
Note
2003670000
A.65
Switch-mode power supplies
connectPower INSTAPOWER - Accessories
A
Small screwdriver
Type
SDIK PH1
SDIS 0.5X3.0X100
Blade type
Size/AF
1.00
B
a
b
0.5
3
c
80
100
Order No.
9008570000
9008380000
End bracket
Markers
For DIN rail TS 35
Type
SM 18/9.5 K MC NE WS
A.66
Colour
white
Qty.
200
Order No.
1248580000
Polyamide with fibre glass, screwable
WEW 35/1 SW
Colour
black
Torque
1.2 Nm
Qty.
50
Order No.
1162600000
2003670000
connectPower
Single-phase
Switch-mode power supplies
connectPower WAVEPOWER
CP SNT 12W 24V 0.5A
A
L
AC/DC
N
PWM
+
DC
–
Technical data
Input
Input voltage
Input current
Input frequency
Input fuse
Surge protection
Output
Output voltage
Output current
Output power
Max. residual ripple
Overload protection
Surge protection
Mains failure bridge-over time
Control at 10...100% load
Parallel connection option
Insulation coordination (EN 50178)
electrical isolation, output-earth
electrical isolation, input-earth
electrical isolation, input-output
electrical isolation, I/O rail
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Status indication
Standards
EMC standards
Power factor correction
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
85...265 V AC, 120...300 V DC
260 mA @ 115 V AC; 180 mA @ 230 V AC
50/ 60 Hz
2 A time-lag fuse (internal)
Varistor
24 V DC
0.5 A
12 W
0.1 %
Surge current / thermal cut-out
Varistor
30 ms @ 115 V AC / 80 ms @ 230 V AC
0.6%
No
0.5 kV
1.5 kV
3 kV
4 kV
-20...50 °C
-40 °C...85 °C
80%
Green LED
DIN EN 50178, DIN EN 60950, IEC950
IEC 61000-6 /-2, -3
No
CE; CSA; cULus; EAC; GOSTME25
mm²
mm
Ordering data
Screw connection
Note
Accessories
Note
2003670000
Input/Output
2.5 / 0.5 / 2.5
112.4 / 22.5 / 92.4
Type
CP SNT 12W 24V 0.5A
Qty.
1
Order No.
9918840024
The internal varistor found in a switch-mode power unit does not replace the
necessary surge protection in a system.
Supply voltage 24 V and 0 V can be cross-connected with ZQV 2.5N/2
A.67
Switch-mode power supplies
connectPower DC/DC converter
connectPower
CP DCDC 50W 22-24V 2A
CP DCDC 50W 20-24V 2A
A
'&
²
Chopper
Transformer
Rectifier and
filtering
Chopper
Transformer
Rectifier and
filtering
'&
Technical data
Input
Input voltage
Input fuse
Output
Output voltage
Output current
Overload protection
General data
Ambient temperature (operational)
Storage temperature
Status indication
Switching frequency
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
18...30 V DC, typ. 24 V DC, ± 15%
internal
10…14 V DC, typ. 12V DC, ± 15%
internal
22...24 V DC
2A
Surge current cut-out with self-reset
20.5...29.5 V DC
2A
Surge current cut-out with self-reset
-10...60 °C (Derating ab 50 °C)
-40 °C...85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; EAC
-10...60 °C (Derating ab 50 °C)
-40 °C...85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; EAC
Input/Output
4 / 0.1 / 4
131 / 57 / 98
Input/Output
4 / 0.1 / 4
131 / 57 / 98
Type
CP DCDC 50W 22-24V 2A
Qty.
1
Order No.
9919372424
Type
CP DCDC 50W 22-24V 2A
Qty.
1
Order No.
9919371224
Note
Accessories
Note
A.68
Bracket for wall mounting: 7920560000
Bracket for wall mounting: 7920560000
2003670000
Switch-mode power supplies
connectPower DC/DC converter
CP DCDC 50W 12V 3A
A
Chopper
Transformer
Rectifier and
filtering
18...30 V DC, typ. 24 V DC, ± 15%
internal
10.5...14.5 V DC
3A
Surge current cut-out with self-reset
-10...60 °C (Derating ab 50 °C)
-40 °C...85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; EAC
Input/Output
4 / 0.1 / 4
131 / 57 / 98
Type
CP DCDC 50W 12V 3A
Qty.
1
Order No.
9919372412
Bracket for wall mounting: 7920560000
2003670000
A.69
Switch-mode power supplies
connectPower DC/DC converter
connectPower
CP DCDC 50W 15V 3A
CP DCDC 50W 5V 8A
A
'&
²
Chopper
Transformer
Rectifier and
filtering
Chopper
Transformer
Rectifier and
filtering
'&
Technical data
Input
Input voltage
Input fuse
Output
Output voltage
Output current
Overload protection
General data
Ambient temperature (operational)
Storage temperature
Status indication
Switching frequency
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
18...30 V DC, typ. 24 V DC, ± 15%
internal
18...30 V DC, typ. 24 V DC, ± 15%
internal
15 V DC
3A
Surge current cut-out with self-reset
5 V DC
8A
Surge current cut-out with self-reset
-10...60 °C (Derating ab 50 °C)
-40 °C...85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; EAC
-10...60 °C (Derating ab 50 °C)
-40 °C...85 °C
Green LED
200 kHz
CE; CSA; CSAEX; cULus; EAC
Input/Output
4 / 0.1 / 4
131 / 57 / 98
Input/Output
4 / 0.1 / 4
131 / 57 / 98
Type
CP DCDC 50W 15V 3A
Qty.
1
Order No.
9919372415
Type
CP DCDC 50W 5V 8A
Qty.
1
Order No.
9919372405
Note
Accessories
Note
A.70
Bracket for wall mounting: 7920560000
Bracket for wall mounting: 7920560000
2003670000
A
2003670000
A.71
Switch-mode power supplies
Switch-mode power supplies
connectPower DC/DC converter
connectPower DC/DC converter
DC voltage converter for preparation and potential isolation
in 24 V DC systems
•OvervoltagecategoryIII
•ClassIIIprotection
•Statusofrelaycontact
•DCOKtransistoroutput
A
%
{ \u
Technical data
Temperature derating
130
Pout [% Pn]
120
110
100
90
80
70
60
20
30
40
50
60
Ambient temperature [°C]
70
80
General technical specifications
Output characteristic curve / current limit
Earth discharge current
Ambient temp. Operating / storage temperature
Max. permitted humidity (operational)
Protection degree
Class of protection
Contamination degree
Insulation voltage
Overvoltage category
MTBF
Protection against load reverse voltages
Parallel capability (without diode module)
Mountable side-by-side without gaps
Housing version, metal
Signal operations
Mounting position, installation notice
Metal clip-on foot
EMC / shock / vibration
Noise emission according to EN55022
Interference immunity tests, according to
Limiting of mains voltage harmonic currents
Resistance against vibration and shock
Electrical safety (applied standards)
Electrical equipment of machines
Safety transformers for switched-mode power units
Machinery with electronic equipment
Safety extra-low voltage
Protective separation / protection against electrical shock
Protection against dangerous shock currents
Accessories
Diode module (for redundant power supply)
Capacity module (for pulse triggering of circuit breakers)
A.72
IU / > 120 % IR
< 0.005 mA
–25 °C … +70 °C / –40 °C … +85 °C
5 %…95 % RH
IP 20
III
2
2.5 kV AC 1 min. / 1.5 kV AC 1 min. / 0.5 kV AC 1 min.
III
> 500,000 hrs. according to IEC 1709 (SN29500)
33…34 V DC
Yes, max. 5
Yes
Resistant to corrosion
LED green / red
Horizontal on TS 35 DIN rail, above and below 50 mm
Clearance for air circulation, suitable for aligning without clearance gap
For installation in rotating systems
Yes
Class B
EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (Fields),
EN61000-4-4 (Burst), EN61000-4-5 (Surge), EN610004-6 (conducted),
EN61000-4-11 (Dips)
According to EN 61000-3-2
According to EN50178, shock: 5 g in all directions
According to EN60204
According to EN61558-2-17
According to EN50178 / VDE0160
SELV according to EN60950, PLEV according to EN60204
VDE0100-410 / according to DIN57100-410
According to VDE0106-101
Type
CP M DM 20
CP M CAP
Qty.
1
1
Order No.
1222210000
1222240000
2003670000
connectPower
DC/DC converter
Switch-mode power supplies
connectPower DC/DC converter
CP DCDC 250W 24V 10A
A
+
+
DC
–
–
DC OK
14
13
DC
Technical data
Input
Rated input voltage / DC input voltage range
DC current consumption
Inrush current
Input fuse (internal)
Recommended back-up fuse
24 V DC / 18 ... 31.2 V DC
Typ.: 11 A, Max.: 15.5 A
Max. 10 A
Yes
16 A / DI/II safety fuse, 16 A, Char. B circuit breaker, 16 A, Char. C
circuit breaker
Output
Rated output voltage
Output voltage
Ramp-up time
Residual ripple, breaking spikes
Rated (nominal) output current @ UNom
Short-circuit protection / Overload protection
Powerboost @ 24 V DC, 60 °C
General data
Degree of efficiency
Power loss
AC failure bridging time @ INom
Tightening torque
Reverse polarity protection
Depth x width x height / Weight
Signalling
Status indicator
24 V DC ± 1 %
≤ 100 ms
< 50 mVSS @ 24 V DC, IN
10 A @ 60 °C
Yes / Yes
12 A for 1 min, ED = 5 %
typ. 91%
Idle: max. 2 W, Nominal load: 24 W
> 7 ms @ 24 V DC
0.5...0.6 Nm
Yes
150 / 60 / 130 mm / 1250 g
LED green (DC OK): output voltage ≥ 21.6 V, LED red (fault): output
voltage ≤ 20.4 V
Output voltage ≥ 21.6 V ( max. 250 mA)
Output voltage ≤ 20.4 V / Yes
Yes
max. 30 V DC / 0.5 A
Output voltage > 21.6 V / < 20.4 V
DC OK transistor output „1“ (max. load)
DC OK transistor output „0“ / DC OK short circuit resistant
Floating contact
Contact load
Relay on/off
Approvals
Approvals
Connection data
Wire connection method
Number of terminals
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Note
Ordering data
cULus; EAC; GL; TUEV
mm²
mm²
Input
Screw connection
2 for (+ -)
0.5 / 6
0.5 / 2.5
26 / 12
Type
CP DCDC 250W 24V 10A
Output
Screw connection
7 for (DCOK, 13,14, + + --)
0.5 / 6
0.5 / 2.5
26 / 12
Qty.
1
Order No.
1313320010
Note
Accessories
Note
2003670000
A.73
A
A.74
2003670000
Uninterruptible power supplies (UPS)
Contents
Uninterruptible power supplies (UPS)
Uninterruptible power supplies (UPS)
2003670000
Overview
B.2
UPS control unit
B.4
Battery modules
B.6
Buffer modules
B.8
B
B.1
Uninterruptible power supplies (UPS)
Uninterruptible power supplies (UPS) – Overview
Uninterruptible power supplies
Weidmüller‘s uninterruptible power supplies reliably protect
24 V DC consumers from voltage drop-outs and dips, such
as those that could occur as a result of mains faults. These
products therefore play a key role in increasing systems
availability.
B
The buffer module is the perfect solution for bridging
short-term power supply failures or dips of up to 100 ms.
The capacitor-based technology enables maintenance-free
operation, depending on the application, of up to 10 years.
The UPS control unit, together with the accompanying
battery module and the power supply, form a complete
DC UPS system with support times in minutes or hours.
The modular construction allows for the overall load to be
distributed into non-safe and safe load circuits, such that
often a smaller UPS can be designed.
A huge variety of operating types are available to suit the
particular application precisely. A remote input to block
battery operation, as well as multiple signal outputs, enable
remote operation of the UPS.
UPS with battery module
0DLQV
5HPRWHGLVFRQQHFWLRQ
,QWHUORFN
3520
$&
'&
9'&
²
5HOD\DQG
WUDQVLVWRURXWSXWV
&3'&8369
836FRQWUROXQLW
9'&
²
6DIH
ORDG
%DWWHU\PRGXOH
&3$%DWWHU\9'&
1RQVDIH
ORDG
UPS with buffer module
Relay and
transistor ouput
Mains
PRO-M
AC
DC
+24 V DC
+
–
CP DC BUFFER 24V 20A
+
Buffer module +24 V DC Safe
load
–
Non-safe
load
B.2
2003670000
Can your facility afford to experience a power failure? Allow us
to connect you so that you are safe from failure and downtime.
Let’s connect.
Uninterruptible power supplies (UPS)
Uninterruptible power supplies (UPS) – Overview
B
It is critical to safeguard a facility‘s power supply in the event
of an outage. You cannot do without the important signals
from the field, which serve to control the entire process.
In addition, you also need to monitor a whole range of
functions and performance parameters for your facility.
Our highly modular power supply concept will support you
in the practical fulfilment of all your requirements. At the
same time, we will also familiarise ourselves with your future
requirements and provide you with an individual, tailor-made
solution, with components that are precisely aligned to work
with one another.
For a continual, lasting power supply and clean control
voltage, we use redundant circuits, selective short-circuit
solutions, battery reservoirs and DC/DC converters.
And because lightning and power surges can put an
uninterrupted power supply in a production facility at
risk, we also provide lightning and overvoltage protection.
The VPU series provides unrestricted operation of power
supplies and automation devices such as sensors, actuators
and control units. The subsequent availability of the power
supply means that all devices will restart in a controlled
manner. Let’s connect.
2003670000
PRO-M
•
•
•
•
•
Used to save space in automation technology
Individual modulation of the output power
Up to 5 devices can be switched directly, in parallel
Optional diode modules with fault signalling
Expanded temperature range –25 °C to 70 °C
UPS control unit
• Different status relays for status monitoring
• Direct switchover to battery operation in the event of
malfunction
• Automatic reconnection to load when power recovers
• Long battery life due to integrated deep discharge protection
• Optimised charging feature
B.3
Uninterruptible power supplies (UPS)
UPS control unit
• Two 24 V models in 10 A/20 A and 40 A
• Temperature-compensated charging feature for long
battery life
• Integrated battery diagnostics including continuous
availability test
• Status relay and additional transistor outputs for remote
monitoring
• Convenient LED displays for easy error analysis
B
{ \u
%
Technical data
Indication
Status relay ( max.load 30 V AC/DC 0.1 A)
Transistor outputs (24 to 27 V DC max. load 150 mA)
LED status indicator
General technical data
Ambient temperature (operational)
Storage temperature
Max. perm. air humidity
Protection degree
Class of protection
Pollution severity level
Overvoltage category
Insulation voltage input/output to housing/ground
MTBF
Protection against reverse voltages from the load
Parallel connection option
Housing version
Mounting position, installation notice
Overload protection
Short-circuit protection
EMC / shock / vibration
Interference emission
Interference immunity tests
Resistance against vibration and shock
Electrical safety (applied standards)
Electrical equipment of machines
Safety transformers for switch-mode power supplies
Machinery with electronic equipment
Extra-low voltage protection
Block diagram
Interlock – 1
Interlock + 2
Temperature 6
Sensor 7
–25 °C…+70 °C
–40 °C…+85 °C
5…95 %
IP 20
3
2
III
1300 V DC 1 min (typetest)
> 500,000 hours acc. to IEC 1709
32…34 V DC
Yes, only with diode module for redundancy
Metal, corrosion resistant
Horizontal on mounting rail TS 35, 50 mm above and below
Space for free movement of air
Yes
Yes
Acc. to EN55022 Class B
Acc.to EN61000-4-2 (ESD), EN61000-4-3 and EN61000-4-8 (fields),
EN61000-4-4 (burst), EN61000-4-5 (surge), EN610004-6 (conducted),
EN61000-4-11 (dips)
Acc.to IEC60954 Vibration: 2.3 g,
Acc.to IEC60068-2-31 shock: 30 g in all directions
Acc. to EN60204
Acc. to EN61558-2-17
Acc. to EN50178 / VDE0160
SELV acc. to EN60950, PLEV acc. to EN60204
Cabling
3 Alarm
Battery Capacity
Normal / Buffering
Alarm
Cut-off / Bat.Failure
Selector switches
– Buffer time
– Battery size
– DIP switch
– 10/20A
(only1370050010)
4 Buffering
5 Charging
11
14 Alarm
12
21
24 Buffering
22
31
34 Charging
32
+
µC
+
24V DC
Input
Charger
–
24V DC
Output
–
Bat
–
B.4
Fault (alarm), battery operation (buff.), charging (charg.)
Fault (alarm), battery operation (buff.), charging (charg.)
Three-colour LED: battery capacities
> 85 % green, > 40 % yellow, > 20 % red, < 20 % red (flashing)
Green/yellow LED: normal / buffering
Yellow/red LED: temperature alarm / alarm
Yellow/red LED: switch-off / battery fault
+ +
Unbuffered
DC Load
– +
– + + –
24V DC Output
Buffered
DC Load
– +
– + – + – +
Input Battery Output
+
–
Power Supply
DC UPS
Battery Module
PRO–M Series
CP DC UPS 24V DC 20A/10A
CP DC UPS 24V DC 40A
CP A BATTERY 24V DC .. Ah
1 2 3 4 5 11 21 31
6 7 12 14 22 24 32 34
7
6
Temperature Sensor
2003670000
UPS control unit
CP DC UPS 24V 20A/10A
Uninterruptible power supplies (UPS)
UPS control unit
CP DC UPS 24V 40A
B
Technical data
Input
Rated input voltage
DC input voltage range
Input current
Input fuse (internal)
DC current consumption
Reverse polarity protection
Output
Rated output voltage
Output voltage
Rated (nominal) output current @ UNom
continous output current @ 24 V DC
Powerboost @ 24 V DC, 60 °C
Integrated battery charger
Charging feature
Charging voltage (temperature compensated)
Temperature coefficient
Charging current
Battery availability test
Battery module
Rated voltage
Storage medium
Parallel connection option [battery]
Operating elements and control inputs
Output current selector switch
Selector switch battery
Selector switch buffer times
DIP switch
Remote disconnection (Interlock)
Temperature probe
General data
Buffer times
Degree of efficiency
Power loss
Depth x width x height / Weight
Approvals
Approvals
Connection data
Wire connection method
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Tightening torque
Note
Ordering data
mm²
mm²
Nm
24 V DC
20...30 V DC
≤ 13A (for 10A), ≤ 23A (for 20A)
Yes
max. 200 mA (without battery), max. 0.5 A (with fully charged
battery)
Yes
20...30 V DC
≤ 43 A
Yes
max. 200 mA (without battery), max. 0.5 A (with fully charged
battery)
Yes
24 V DC ± 1 %
Vo = Vin - 0.2 V normal operation (Imax), Vo = Vin - 0.3 V battery
operation (Imax)
20 A @ 60 °C
24 A @ 45 °C, 20 A @ 60 °C, 15 A @ 70 °C
24 A for 1 min, ED = 5 %
24 V DC ± 1 %
Vo = Vin - 0.2 V normal operation (Imax), Vo = Vin - 0.3 V battery
operation (Imax)
40 A @ 60 °C
48 A @ 45 °C, 24 A @ 70 °C, 40 A @ 60 °C
48 A for 1 min, ED = 5 %
IU characteristic curve
27, 48 V @ 20°C
- 48 mV / °C
0.15 CA
every minute
IU characteristic curve
27, 48 V @ 20°C
- 48 mV / °C
0.15 CA
every minute
24 V
1.3 Ah, 3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah, Selectable with rotary switch
yes, max 2.
24 V
3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah, Selectable with rotary switch
yes, max 2.
20 A, 10 A
1.3 Ah, 3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah, No Battery, Service
0.5 min, 1 min, 3 min, 5 min, 10 min, 20 min, 30 min, 45 min, ∞,
∞ w/0
Inversion of transistor outputs, Operation without temperature probe
Yes
NTC 100 kΩ
3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah, No Battery, Service
0.5 min, 1 min, 3 min, 5 min, 10 min, 20 min, 30 min, 45 min, ∞,
∞ w/0
Inversion of transistor outputs, Operation without temperature probe
Yes
NTC 100 kΩ
Depending on the connected battery
≥ 96% normal mode, battery is being charged, ≥ 98% normal mode,
battery is charged, ≥ 98% buffer mode
< 10 W
150 / 66 / 130 mm / 980 g
Depending on the connected battery
≥ 96% normal mode, battery is being charged, ≥ 98% normal mode,
battery is charged, ≥ 98% buffer mode
< 10 W
150 / 66 / 130 mm / 1000 g
CE; EAC; GL; GOSTME25
CE; EAC; GL; GOSTME25
Input/output/battery
Screw connection
0.5 / 16
0.5 / 16
26 / 6
1.2...1.5
Type
CP DC UPS 24V 20A/10A
Signal
Screw connection
0.5 / 16
0.5 / 16
26 / 12
Qty.
1
Order No.
1370050010
Input/output/battery
Screw connection
0.5 / 16
0.5 / 16
26 / 6
1.2...1.5
Type
CP DC UPS 24V 40A
Signal
Screw connection
0.5 / 16
0.5 / 16
26 / 12
Qty.
1
Order No.
1370040010
Note
2003670000
B.5
Uninterruptible power supplies (UPS)
Battery modules
Battery modules
CP A BATTERY 24V DC1.3AH
CP A BATTERY 24V DC3.4AH
• Maintenence-free lead-acid batteries from 3.4 Ah to 17
Ah
• Integrated temperature sensor for optimal battery
charging
• Capacity up to 40 A / 30 min or 1 A / 30 hrs
• Robust metal housing for wall mounting
B
6HQVRU
%XIIHUWLPHVQ>PLQ@
%XIIHUWLPHVRXWSXWFXUUHQWFXUYH
&3$%DWWHU\9'&$K
&3$%DWWHU\9'&$K
6HQVRU
&3$%DWWHU\9'&$K
17&
&3$%DWWHU\9'&$K
17&
&3$%DWWHU\9'&$K
3(
2XWSXWFXUUHQW>$@
3(
Technical data
Rated input voltage
Nominal capacity
Charging current, max.
Overload and short circuit protection
Buffer time 10A
Buffer time 20A
Output current, max.
Parallel connection option
Series switching capability
Temperature probe
General data
Battery type
Operating life
Ambient temperature
Storage temperature
Latest commissioning
Max. perm. air humidity (operational)
Class of protection
Protection degree
Vibration DIN rail/wall in accordance with IEC 68-2-6
Shock wall acc. to IEC 68227
Depth x width x height / Weight
Approvals
24 V DC
1.3 Ah
0.2 A
15 A fuse
3 min
min
15 A
Yes
No
NTC 100 kΩ
24 V DC
3.4 Ah
0.51 A
25 A fuse
11.3 min
5 min
25 A
Yes
No
NTC 100 kΩ
Maintenance-free AGM lead-acid battery
6…9 years @ 20°C
0°...+40°C (Charging); -15°…+50°C (Discharging)
-15 °C...40 °C
9 months
5 %…95 % RH
III, with no ground connection, for SELV
IP 20
0.7 / 0.7 g
30 g
124 / 52 / 148 mm / 1500 g
cULus; EAC; GL
Maintenance-free AGM lead-acid battery
6…9 years @ 20°C
0°...+40°C (Charging); -15°…+50°C (Discharging)
-15 °C...40 °C
9 months
5 %…95 % RH
III, with no ground connection, for SELV
IP 20
0.7 / 0.7 g
30 g
137 / 108 / 144 mm / 3600 g
cULus; EAC; GL
Connection data
Wire connection method
Wire cross-section, rigid min/max
Wire cross-section, flexible min/max
Wire cross-section, AWG/kcmil min/max
Tightening torque
Note
Input/output/battery
Input/output/battery
Ordering data
mm²
mm²
Nm
0.2 / 4
0.2 / 4
30 / 12
0.5...0.5
Type
CP A BATTERY 24V DC1.3AH
Signal
Pluggable screw connection
0.2 / 4
0.2 / 4
30 / 12
Qty.
1
Order No.
1406930000
0.2 / 6
0.5 / 6
22 / 10
0.5...0.6
Type
CP A BATTERY 24V DC3.4AH
Signal
Pluggable screw connection
0.2 / 1.5
0.2 / 1.5
28 / 16
Qty.
1
Order No.
1251070000
Note
Accessories
Note
B.6
2003670000
CP A BATTERY 24V DC7.2AH
CP A BATTERY 24V DC12AH
6HQVRU
CP A BATTERY 24V DC17AH
6HQVRU
17&
17&
3(
3(
24 V DC
7.2 Ah
1.08 A
2x25 A fuse
26.5 min
11.5 min
50 A
Yes
No
NTC 100 kΩ
24 V DC
12 Ah
1.8 A
2x25 A fuse
51 min
22.7 min
50 A
Yes
No
NTC 100 kΩ
24 V DC
17 Ah
2.55 A
2x25 A fuse
81 min
34.2 min
50 A
Yes
No
NTC 100 kΩ
Maintenance-free AGM lead-acid battery
9…12 years @ 20°C
0°...+40°C (Charging); -15°…+50°C (Discharging)
-15 °C...40 °C
9 months
5 %…95 % RH
III, with no ground connection, for SELV
IP 20
- / 0.7 g
30 g
134 / 162 / 155 mm / 5900 g
cULus; EAC; GL
Maintenance-free AGM lead-acid battery
6…9 years @ 20°C
0°...+40°C (Charging); -15°…+50°C (Discharging)
-15 °C...40 °C
9 months
5 %…95 % RH
III, with no ground connection, for SELV
IP 20
- / 0.7 g
30 g
134 / 229 / 155 mm / 9220 g
cULus; EAC; GL
Maintenance-free AGM lead-acid battery
6…9 years @ 20°C
0°...+40°C (Charging); -15°…+50°C (Discharging)
-15 °C...40 °C
9 months
5 %…95 % RH
III, with no ground connection, for SELV
IP 20
- / 0.7 g
30 g
160 / 242 / 178 mm / 13400 g
cULus; EAC
Input/output/battery
Input/output/battery
Input/output/battery
0.2 / 16
0.5 / 16
22 / 6
1.2...1.5
Type
CP A BATTERY 24V DC7.2AH
2003670000
Signal
Pluggable screw connection
0.2 / 1.5
0.2 / 1.5
28 / 16
Qty.
1
Order No.
1251080000
B
6HQVRU
17&
3(
Uninterruptible power supplies (UPS)
Battery modules
0.2 / 16
0.5 / 16
22 / 6
1.2...1.5
Type
CP A BATTERY 24V DC12AH
Signal
Pluggable screw connection
0.2 / 1.5
0.2 / 1.5
28 / 16
Qty.
1
Order No.
1251090000
0.2 / 16
0.5 / 16
22 / 6
1.2...1.5
Type
CP A BATTERY 24V DC17AH
Signal
Pluggable screw connection
0.2 / 1.5
0.2 / 1.5
28 / 16
Qty.
1
Order No.
1251110000
B.7
Uninterruptible power supplies (UPS)
Buffer modules
Buffer modules
CP DC BUFFER 24V 20A
• Maintenance-free UPS on capacitor basis with a
capacity to support 20 A / 260 ms
• Parallel switching to increase the output current or
support time
• Status notification via LED and relay contact
B
%ORFNGLDJUDP
,QSXW
²
2XWSXW
²
5HDG\
²
)DLO
Technical data
Input
Rated input voltage
Input current
Max. approved input current
Surge protection
Output
Output voltage
Output current
Output current, max.
Parallel connection option
Overload protection
Surge protection
Status relay (max. load)
24 V DC
0…22 A
22 A
31 ... 34 V (only at discharge)
24 V
20 A
22 A
Yes, without diode module
≥ 22 A (only at discharge)
31 ... 34 V (only at discharge)
Input voltage OK (30 V AC/DC 2A), Ready for operation (24 V AC/
DC 300 mA)
Display
Status indicator
General data
Degree of efficiency
Insulation voltage, input/output
Storage medium
Buffer times
MTBF
Ambient temperature (operational)
Storage temperature
Humidity
Depth x width x height / Weight
For use with electronic equipment
EMC standards
Approvals
Connection data
Wire connection method
Wire cross-section, rigid min/max
Note
Ordering data
Green LED
95 %
1 kV
Internal condenser
250 ms at 20 A, 6 s at 1 A
> 500,000 h acc. to IEC 1709 (SN29500
-25 °C...70 °C
-40 °C...85 °C
5...95 %, no condensation
150 / 66 / 130 mm / 1150 g
Acc. to EN50178 / VDE0160
CE; TUEV; cULus; cURus
mm²
Input
Screw connection
Output
Type
CP DC BUFFER 24V 20A
Signal
Qty.
1
Order No.
1251220000
Note
Accessories
Note
B.8
2003670000
Small metal foot
Type
MTA 30 MF
Large metal foot
Order No.
1251320000
Small wall mounting
Type
CP A WALLADAPTER 30 MM
Small plastic foot
Type
MTA 45 MF
Order No.
1251310000
Large wall mounting
Order No.
1461870000
Type
CP A WALLADAPTER 45 MM
Order No.
1461850000
2003670000
Order No.
1168970000
Type
MTA 45 BK
Order No.
1962250000
B
Type
CP DC UPS TF25
CP DC UPS TF05
Cable length
2.5 m
0.5 m
Order No.
1444540000
1444480000
Large screwdriver
Blade type
B
Size/AF
a
0.5
b
3
c
100
Order No.
9008380000
Type
SDIS 1.0X5.5X125
Blade type
B
Size/AF
a
1
b
5.5
c
125
Order No.
9008410000
Qty.
50
Order No.
1162600000
End bracket
Markers
Type
SM 18/9.5 K MC NE WS
Large plastic foot
Temperature probe
Small screwdriver
Type
SDIS 0.5X3.0X100
Type
MTA 30 BK
Uninterruptible power supplies (UPS)
UPS control unit - Accessories
For DIN rail TS 35
Colour
white
Qty.
200
Order No.
1248580000
Polyamide with fibre glass, screwable
WEW 35/1 SW
Colour
black
Torque
1.2 Nm
B.9
B
B.10
2003670000
Uninterruptible power supplies (UPS)
Fuse protection for 24 V DC circuits
Contents
Fuse protection for 24 V DC circuits
Fuse protection for 24 V DC circuits
Overview
C.2
WAVEGUARD
C.4
C
2003670000
C.1
Fuse protection for 24 V DC circuits
Fuse protection for 24 V DC circuits – Overview
Fuse protection
A 24 V DC control voltage has become the standard in the
automation industry. Selective fuse protection is often used
when the power is being supplied by PLC-guided controllers.
It divides the total load into separate, logically connected
safety circuits. For example, the CPU, actuators and sensors
can be separated in the load circuits. This selective load
protection helps to decrease facility downtime and also to
simplify troubleshooting. When a disruption (short circuit)
occurs on a standard protective system, the entire power
supply is interrupted. In a system using selective fuse
protection, only the fuse in the one disrupted load circuit is
triggered. If the fuse is triggered quick enough so that other
loads (and particularly the CPU) can continue functioning
properly, then various control algorithms can be used to
deal with the disruption. It is then possible to shut down the
facility in an orderly and controlled fashion.
C
A fundamental problem when using ordinary fuses is
that they take a relatively long time to trigger. Usually, a
C.2
switched-mode power supply is already well over the surgecurrent limit (typically 120 % of Inom) before its fuse triggers.
Ordinary fuses are therefore not suitable for constructing a
selective fuse protective system. Such systems present DC
fuses with special challenges. They must be able to switch
off quickly enough but they must also be able to tolerate the
start-up surge currents from consumer loads. Weidmüller‘s
electronic fuses, from our established WAVEGUARD line,
are the answer to both of these challenges: they are quick
acting but can also tolerate start-up currents. You can easily
implement selective load protection using our WAVEGUARD
models.
In addition, Weidmüller‘s electronic fuses feature a floating
alarm contact and a reset input. This allows a PLC controller
to query the status of the fuse or to perform an automated
reset after troubleshooting. This provides you with a
convenient method for remotely maintaining a complex
facility. As a result, you save both time and money.
2003670000
Fuse protection for 24 V DC circuits
Fuse protection for 24 V DC circuits – Overview
Resetting
The WAVEGUARD family can be reset manually or by using
an external signal. They can be reset remotely by simply
applying a 24 V signal pulse on the reset input. The reset
occurs on the falling edge of the signal.
Note: A cyclical automatic reset is not permitted and can
lead to a malfunction.
BLOCK DIAGRAM WAVEGUARD
INPUT
24 V
Reset
(8)
(1)
(9)
gn
24 V
fail
C
re
(2)
0V
OUTPUT
(7)
(3)
NC contact
50 Vuc/0.05A
Signalling
A red LED displays when the electronic fuse has been
triggered. An alert is also sent out over a floating alarm
contact. A green LED signals that the unit is switched on.
The alarm contact uses an NC contact.
WAVEGUARD
2003670000
C.3
Fuse protection for 24 V DC circuits
WAVEGUARD
INPUT
24 V
Reset
C
24 V DC 3.15 A
24 V DC 1.6 A
0V
(8)
(1 )
(9 )
gn
rt
OUTPUT
24 V
fail
(7 )
(2 )
(3 )
NC contact
50 V uc /0.05 A
Current
(A )
Current
(A )
20
18
16
14
12
10
8
6
4
2
0
24
22
20
18
16
14
12
10
8
6
4
2
0
Time ( m s )
0
20
40
60
80
10 0
12 0
14 0
T i m e ( m s)
0 10 15 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0
16 0
Technical data
Input
Rated control voltage
Rated current
Reset
Output
Status relay / CO contact
Signalling delay
General data
Ambient temperature (operational)
Storage temperature
Status indication
Standards
EMC standards
Sliding switch
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
Tension-clamp connection
24 V DC
1.6 A
Impulse > 100 ms +24 V, falling edge ON
24 V DC
3.15 A
Impulse > 100 ms +24 V, falling edge ON
NC contact, max. 50 V / 0.05 A; for low voltage only!
3.5 ms typ.
NC contact, max. 50 V / 0.05 A; for low voltage only!
3.5 ms typ.
0 °C...55 °C
-20 °C...85 °C
LED green: OK, LED red: tripped
DIN EN 50178
EN 55011, EN 61000-6-1, 2, 4
OFF - wait 10 s - ON; on / off
cCSAus; CE; cURus; EAC; GOSTME25
0 °C...55 °C
-20 °C...85 °C
LED green: OK, LED red: tripped
DIN EN 50178
EN 55011, EN 61000-6-1, 2, 4
OFF - wait 10 s - ON; on / off
cCSAus; CE; cURus; EAC; GOSTME25
2.5 / 0.5 / 2.5
1.5 / 0.5 / 2.5
92.4 / 22.5 / 72
92.4 / 22.5 / 72
Periodic
auto-reset not permitted; Tu=23 °C,Tension
single module
Screw connection
clamp connection
2.5 / 0.5 / 2.5
1.5 / 0.5 / 2.5
92.4 / 22.5 / 72
92.4 / 22.5 / 72
Periodic
auto-reset not permitted; Tu=23 °C,Tension
single module
Screw connection
clamp connection
Type
WGS 24Vdc 1,6A
WGZ 24Vdc 1,6A
Type
WGS 24Vdc 3,15A
WGZ 24Vdc 3,15A
Qty.
1
1
Order No.
8618890000
8621040000
Qty.
1
1
Order No.
8618910000
8621030000
Note
Accessories
Note
C.4
Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5 N/2
Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5 N/2
2003670000
24 V DC 6.3 A
INPUT
24 V
Reset
0V
(8)
(1 )
(9 )
gn
rt
24 V
fail
(7 )
(2 )
(3 )
24 V DC 8 A
Current
(A )
Current
(A )
OUTPUT
NC contact
50 V uc /0.05 A
26
24
22
20
18
16
14
12
10
8
6
4
Time (ms)
0
10
Fuse protection for 24 V DC circuits
WAVEGUARD
15 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0
65
60
55
50
45
40
35
30
25
20
15
10
5
C
Time (ms)
0
5
10
15
20
25
30
35
40
45
50
Technical data
Input
Rated control voltage
Rated current
Reset
Output
Status relay / CO contact
Signalling delay
General data
Ambient temperature (operational)
Storage temperature
Status indication
Standards
EMC standards
Sliding switch
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
Tension-clamp connection
24 V DC
6.3 A
Impulse > 100 ms +24 V, falling edge ON
24 V DC
8A
Impulse > 100 ms +24 V, falling edge ON
NC contact, max. 50 V / 0.05 A; for low voltage only!
3.5 ms typ.
NC contact, max. 50 V / 0.05 A; for low voltage only!
3.5 ms typ.
0 °C...55 °C
-20 °C...85 °C
LED green: OK, LED red: tripped
DIN EN 50178
EN 55011, EN 61000-6-1, 2, 4
OFF - wait 10 s - ON; on / off
cCSAus; CE; cURus; EAC; GOSTME25
0 °C...55 °C
-20 °C...85 °C
LED green: OK, LED red: tripped
DIN EN 50178
EN 55011, EN 61000-6-1, 2, 4
OFF - wait 10 s - ON; on / off
cCSAus; CE; cURus; EAC; GOSTME25
2.5 / 0.5 / 2.5
1.5 / 0.5 / 2.5
92.4 / 22.5 / 72
92.4 / 22.5 / 72
Periodic
auto-reset not permitted; Tu=23 °C,Tension
single module
Screw connection
clamp connection
2.5 / 0.5 / 2.5
1.5 / 0.5 / 2.5
92.4 / 22.5 / 72
92.4 / 22.5 / 72
Periodic
auto-reset not permitted; Tu=23 °C,Tension
single module
Screw connection
clamp connection
Type
WGS 24Vdc 6,3A
WGZ 24Vdc 6,3A
Type
WGS 24Vdc 8,0A
WGZ 24Vdc 8,0A
Qty.
1
1
Order No.
8618930000
8621020000
Qty.
1
1
Order No.
8618940000
8621010000
Note
Accessories
Note
2003670000
Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5 N/2
Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5 N/2
C.5
Fuse protection for 24 V DC circuits
WAVEGUARD
24 V DC 0.5...5 A
INPUT
24 V
Reset
C
0V
(8)
(1 )
(9 )
gn
rt
OUTPUT
24 V
fail
(7 )
(2 )
(3 )
NC contact
50 V uc /0.05 A
Technical data
Derating curve
Input
Rated control voltage
Rated current
Reset
Output
Status relay / CO contact
Signalling delay
General data
Ambient temperature (operational)
Storage temperature
Status indication
Standards
EMC standards
Sliding switch
Approvals
Dynamic tripping characteristic
24 V DC
0.5...5 A adjustable
Impulse > 100 ms +24 V, falling edge ON
Tripping current: 0.5 A
Tripping current (A)
25
20
15
10
5
0
0
20
40
NC contact, max. 50 V / 0.05 A; for low voltage only!
3.5 ms typ.
0 °C...55 °C
-20 °C...85 °C
LED green: OK, LED red: tripped
DIN EN 50178
EN 55011, EN 61000-6-1, 2, 4
OFF - wait 10 s - ON; on / off
cCSAus; CE; cURus; EAC; GOSTME25
mm²
mm
Ordering data
Screw connection
Tension-clamp connection
80
100
120
140
60
80
100
120
140
Time (ms)
Tripping current: 5.0 A
Tripping current (A)
25
20
15
10
5
0
0
20
40
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
60
Time (ms)
2.5 / 0.5 / 2.5
1.5 / 0.5 / 2.5
92.4 / 22.5 / 72
92.4 / 22.5 / 72
Periodic
auto-reset not permitted; Tu=23 °C,Tension
single module
Screw connection
clamp connection
Type
WGS 24Vdc 0.5...5A
WGZ 24Vdc 0.5...5A
Qty.
1
1
Order No.
8710270000
8727630000
Note
Accessories
Note
C.6
Supply voltage +24 V and 0 V can be cross-connected with ZQV 2.5 N/2
2003670000
Unregulated power supplies
Contents
Unregulated power supplies
Unregulated power supplies
Overview
D.2
compactPower
D.4
D
2003670000
D.1
Unregulated power supplies
Unregulated power supplies – Overview
Unregulated power supplies – compactPower
Compact power supply units are important links in the
power supplies for controllers. They are used where
processes or control voltages are required that vary from the
mains voltage. Transformers provide the electrical isolation
between the input circuit and the output circuit.
The minimum requirement (to VDE 0550) is 2,000 V.
Screw terminals secure the input-side connection to the
mains. The single-phase devices are rated for a nominal
voltage of ∼230 ± ∼15 V, or ∼400 V ± ∼15 V, 50/60 Hz,
the 3-phase devices for 3 x 400 V ± 5 %. The secondary
DC voltage from the transformer is conducted to a bridge
rectifier where it is rectified.
D
Single-phase unregulated power supplies
D.2
The pulsating DC voltage is then fed from the rectifier and
filtered to a low residual ripple by means of an electrolytic
capacitor.
This DC voltage is then fed to the output terminal. These
are designed as pluggable screw terminals. A varistor is
integrated in the output circuitry to attenuate voltage peaks.
The operating status is indicated by means of a green LED
via the output circuit. Devices with 600 W and higher are
equipped with a fan.
Three-phase unregulated power supplies
2003670000
Unregulated power supplies
Unregulated power supplies – Overview
Well-balanced spectrum for optimum economy
Block diagram for single-phase devices CP NT
The output currents of these practical products are defined
by way of two ambient temperatures.
Size selection is based on the maximum effectiveness of the
components.
INPUT
+15 V
0V
–15 V
230 V
400 V
PE
Adapted to standard voltages in accordance
with IEC 38
By choosing the appropriate terminals, the ± 15 V tapping
capability allows the single-phase devices to be connected
to six different nominal AC voltages: 215, 230, 245, 385,
400, 415 V.
The ± 5 % tapping capability allows the 3-phase devices to
be connected to three different nominal voltages: 380, 400,
415 V.
Reliable short-circuit and overload protection
Integrated on the secondary side in device sizes up to
CP NT 192 W, the FKS fuse protects against overloads
and shortcircuits. For the devices CP NT 264 W and
CP NT 432 W, this protection is achieved by means of a
thermostatic switch built into the transformer.
.
.
.
.
.
D
Block diagram for 3-phase devices
CP NT3 250 / 400 / 500 W
INPUT
+5% 400 V –5% +5% 400 V –5% +5% 400 V –5%
3x
OUTPUT
+
+
24V DC
=
130°
PE
-
~
Block diagram for 3-phase devices
CP NT3 600 / 750 / 1.000 W
Easy mounting
Keyhole assembly simplifies mounting and saves time. A
snap-on fixing attachment for 35 mm DIN rails is available as
an accessory for single-phase devices up to 144 W.
Simply plugged into the device and secured with two
screws, it ensures easiest possible mounting!
OUTPUT
+
+
24V DC
INPUT
+5% 400 V –5% +5% 400 V –5% +5% 400 V –5%
3x
=
130°
M
PE
~
OUTPUT
+
+
24V DC
0V
Fail
Transformers, vacuum-impregnated, painted black
•
•
•
•
•
No humming
Moisture cannot ingress into the windings
Windings mechanically secured
Improved heat dissipation from the windings
Good heat dissipation
Unregulated power supplies
single-phase
Unregulated power supplies
3-phase
2003670000
D.3
Unregulated power supplies
compactPower
compactPower single-phase
CP NT 36
CP NT 72
INPUT
OUTPUT
+15V
0V
-15V
230V
400V
PE
D
.
.
.
.
INPUT
+
+
24VDC
+15V
0V
-15V
-
230V
400V
PE
.
OUTPUT
+
+
24VDC
.
.
.
.
.
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C
Output current at 55°C
Output power
Max. residual ripple
Fuse, max.
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Mounting position, installation notice
Installation advice
Status indication
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
230 V/ 400 V ±15 V
0.35 A/ 0.2 A
50/ 60 Hz
0.1 A / 0.06 A
0.63 A / 0.315 A time-lag
230 V/ 400 V ±15 V
0.56 A/ 0.32 A
50/ 60 Hz
0.13 A / 0.08 A
0.1 A / 0.63 A time-lag
24 V SELV
1.5 A
1A
36 W
<5%
3 A time-lag flat cable-lug fuse
Varistor
24 V SELV
3A
2.5 A
72 W
<5%
7.5 A time-lag flat cable-lug fuse
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20 °C...55 °C
-20 °C...80 °C
80%
Arbitrary, horizontally, on terminal rail TS 35
Direct mounting, TS 35 with clip-on plate
Green LED
1.5 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; EAC
-20 °C...55 °C
-20 °C...80 °C
83%
Arbitrary, horizontally, on terminal rail TS 35
Direct mounting, TS 35 with clip-on plate
Green LED
2.1 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; EAC
Input
2.5 / 0.13 / 2.5
68 / 78 / 123
Input
2.5 / 0.13 / 2.5
85 / 84 / 125
Type
CP NT 36W 24V 1.5A
Output
2.5 / 0.5 / 4
68 / 78 / 123
Qty.
1
Order No.
8575260000
Type
CP NT 72W 24V 3A
Output
2.5 / 0.5 / 4
85 / 84 / 125
Qty.
1
Order No.
8575270000
Note
Accessories
Note
D.4
Clip-in plate for TS 35: 8588920000
Clip-in plate for TS 35: 8588920000
2003670000
compactPower single-phase
CP NT 144
CP NT 192
INPUT
OUTPUT
+15V
0V
-15V
230V
400V
PE
Unregulated power supplies
compactPower
.
.
.
.
INPUT
+
+
24VDC
+15V
0V
-15V
-
230V
400V
PE
.
OUTPUT
+
+
24VDC
.
.
.
.
.
D
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C
Output current at 55°C
Output power
Max. residual ripple
Fuse, max.
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Mounting position, installation notice
Installation advice
Status indication
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
230 V/ 400 V ±15 V
0.95 A/ 0.55 A
50/ 60 Hz
0.33 A / 0.19 A
1.6 A / 1.0 A time-lag
230 V/ 400 V ±15 V
1.3 A/ 0.7 A
50/ 60 Hz
0.3 A / 0.16 A
2.0 A / 1.25 A time-lag
24 V SELV
6A
5A
144 W
<5%
10 A time-lag flat cable-lug fuse
Varistor
24 V SELV
8A
7A
192 W
<5%
15 A time-lag flat cable-lug fuse
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20 °C...55 °C
-20 °C...80 °C
88%
Arbitrary, horizontally, on terminal rail TS 35
Direct mounting, TS 35 with clip-on plate
Green LED
3.1 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; EAC
-20 °C...55 °C
-20 °C...80 °C
90%
Input
2.5 / 0.13 / 2.5
92 / 96 / 135
Input
2.5 / 0.13 / 2.5
105 / 105 / 145
Type
CP NT 144W 24V 6A
Direct mounting
Green LED
4.3 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; EAC
Output
2.5 / 0.5 / 4
92 / 96 / 135
Qty.
1
Order No.
8575280000
Type
CP NT 192W 24V 8A
Output
2.5 / 0.5 / 4
105 / 105 / 145
Qty.
1
Order No.
8575300000
Note
Accessories
Note
2003670000
Clip-in plate for TS 35: 8588920000
D.5
Unregulated power supplies
compactPower
compactPower single-phase
CP NT 264
CP NT 432
INPUT
OUTPUT
+15V
0V
-15V
230V
400V
PE
D
.
.
.
.
INPUT
+
+
24VDC
+15V
0V
-15V
-
230V
400V
PE
.
OUTPUT
+
+
24VDC
.
.
.
.
.
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C
Output current at 55°C
Output power
Max. residual ripple
Fuse, max.
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Installation advice
Status indication
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
230 V/ 400 V ±15 V
1.8 A/ 1 A
50/ 60 Hz
0.5 A / 0.28 A
3.15 A / 1.6 A time-lag
230 V/ 400 V ±15 V
2.5 A/ 1.3 A
50/ 60 Hz
0.54 A / 0.31 A
4.0 A / 2.0 A time-lag
24 V SELV
11 A
10 A
264 W
<5%
Thermostatic switch
Varistor
24 V SELV
18 A
15 A
432 W
<5%
Thermostatic switch
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20 °C...55 °C
-20 °C...80 °C
93%
Direct mounting
Green LED
6.1 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; EAC
-20 °C...55 °C
-20 °C...80 °C
95%
Direct mounting
Green LED
9.1 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
CE; cULus; EAC
Input
2.5 / 0.13 / 2.5
113 / 120 / 165
Input
2.5 / 0.13 / 2.5
135 / 135 / 185
Type
CP NT 264W 24V 11A
Output
2.5 / 0.5 / 4
113 / 120 / 165
Qty.
1
Order No.
8575310000
Type
CP NT 432W 24V 18A
Output
2.5 / 0.5 / 4
135 / 135 / 185
Qty.
1
Order No.
8575320000
Note
Accessories
Note
D.6
2003670000
compactPower 3-phase
CP NT3 250
Unregulated power supplies
compactPower
CP NT3 400
INPUT
+5% 400V -5% +5% 400V - 5% +5% 400V -5%
OUTPUT
3x
=
130°
PE
~
INPUT
+
+
24VDC
-
+5% 400V -5% +5% 400V - 5% +5% 400V -5%
OUTPUT
3x
=
130°
PE
~
+
+
24VDC
-
D
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Input fuse
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C / 60°C
Output power
Max. residual ripple
Fuse, max.
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Installation advice
Fan signal
Status indication
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
3 x 400 V ±5 %
0.5 A
50/ 60 Hz
0.1 A
3 x primary thermostatic switch
3 x 1.0 A time-lag
3 x 400 V ±5 %
0.75 A
50/ 60 Hz
0.11 A
3 x primary thermostatic switch
3 x 1.2 A time-lag
24 V SELV
11 A / 10 A
250 W
<2%
External 10 A time-lag
Varistor
24 V SELV
18 A / 16 A
400 W
<2%
External 16 / 18 A slo-blo
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20 °C...60 °C
-20 °C...80 °C
76%
Direct mounting
No integrated fan
Green LED
4.7 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; EAC
-20 °C...60 °C
-20 °C...80 °C
77%
Direct mounting
No integrated fan
Green LED
6.9 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; EAC
Input
2.5 / 0.5 / 2.5
185 / 84 / 192
Input
2.5 / 0.5 / 2.5
220 / 88 / 213
Condensation not allowed
Type
CP NT3 250W 24V 10A
Output
6 / 0.5 / 6
185 / 84 / 192
Qty.
1
Condensation not allowed
Order No.
8628620000
Type
CP NT3 400W 24V 15A
Output
6 / 0.5 / 6
220 / 88 / 213
Qty.
1
Order No.
8628630000
Note
Accessories
Note
2003670000
D.7
Unregulated power supplies
compactPower
compactPower 3-phase
CP NT3 500
CP NT3 600
INPUT
+5% 400V -5% +5% 400V - 5% +5% 400V -5%
OUTPUT
3x
=
130°
PE
~
D
INPUT
+
+
24VDC
-
+5% 400V -5% +5% 400V -5% +5% 400V -5%
OUTPUT
3x
=
130°
M
PE
+
+
24VDC
0V
Fail
~
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Input fuse
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C / 60°C
Output power
Max. residual ripple
Fuse, max.
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Installation advice
Fan signal
Status indication
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
3 x 400 V ±5 %
0.9 A
50/ 60 Hz
0.13 A
3 x primary thermostatic switch
3 x 1.6 A time-lag
3 x 400 V ±5 %
1.2 A
50/ 60 Hz
0.15 A
3 x primary thermostatic switch
3 x 2 A time-lag
24 V SELV
22 A / 20 A
500 W
<2%
External 20 / 22 A slo-blo
Varistor
24 V SELV
26 A / 25 A
600 W
<2%
External 25 / 26 A slo-blo
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20 °C...60 °C
-20 °C...80 °C
78%
Direct mounting
No integrated fan
Green LED
10 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; cULus; EAC
-20 °C...60 °C
-20 °C...80 °C
78%
Direct mounting
Open collector <30 V/ <5 mA during interference
Green LED
11 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; EAC
Input
2.5 / 0.5 / 2.5
220 / 108 / 215
Input
2.5 / 0.5 / 2.5
230 / 108 / 212
Condensation not allowed
Type
CP NT3 500W 24V 20A
Output
6 / 0.5 / 6
220 / 108 / 215
Qty.
1
Condensation not allowed
Order No.
8628650000
Type
CP NT3 600W 24V 25A
Output
6 / 0.5 / 6
230 / 108 / 212
Qty.
1
Order No.
8628660000
Note
Accessories
Note
D.8
2003670000
compactPower 3-phase
CP NT3 750
Unregulated power supplies
compactPower
CP NT3 1000
INPUT
+5% 400V -5% +5% 400V -5% +5% 400V -5%
OUTPUT
3x
=
130°
M
PE
0V
Fail
~
INPUT
+
+
24VDC
+5% 400V -5% +5% 400V -5% +5% 400V -5%
OUTPUT
3x
=
130°
M
PE
+
+
24VDC
0V
Fail
~
D
Technical data
Input
Input voltage
Input current
Input frequency
No-load input current
Input fuse
Ext. Back-up fuse
Output
Output voltage
Output current at 40°C / 60°C
Output power
Max. residual ripple
Fuse, max.
Protective circuit, load side
Insulation coordination (EN 50178)
Electric shock protection
Insulation strength
Insulation class
Protection degree
Class of protection
General data
Ambient temperature (operational)
Storage temperature
Degree of efficiency at max. load
Installation advice
Fan signal
Status indication
Weight
Standards
EMC standards
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
mm²
mm
Ordering data
Screw connection
3 x 400 V ±5 %
1.4 A
50/ 60 Hz
0.16 A
3 x primary thermostatic switch
3 x 2.5 A time-lag
3 x 400 V ±5 %
1.8 A
50/ 60 Hz
0.14 A
3 x primary thermostatic switch
3 x 3.15 A time-lag
24 V SELV
32 A / 30 A
750 W
<2%
External 30 / 32 A slo-blo
Varistor
24 V SELV
42 A / 40 A
1000 W
<2%
External 40 / 42 A slo-blo
Varistor
acc. to BGV A3
4 kV
B
IP 20
I
acc. to BGV A3
4 kV
B
IP 20
I
-20 °C...60 °C
-20 °C...80 °C
77%
Direct mounting
Open collector <30 V/ <5 mA during interference
Green LED
14 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; EAC
-20 °C...60 °C
-20 °C...80 °C
77%
Direct mounting
Open collector <30 V/ <5 mA during interference
Green LED
18 kg
DIN EN 60950, DIN EN 61558-2-4, -6, 72/23/EWG
EN 61000-6 /-2, -3
cCSAus; CE; EAC
Input
2.5 / 0.5 / 2.5
270 / 121 / 255
Input
2.5 / 0.5 / 2.5
280 / 122 / 275
Condensation not allowed
Type
CP NT3 750W 24V 30A
Output
6 / 0.5 / 6
270 / 121 / 255
Qty.
1
Condensation not allowed
Order No.
8628670000
Type
CP NT3 1000W 24V 40A
Output
10 / 0.5 / 10
280 / 122 / 275
Qty.
1
Order No.
8628680000
Note
Accessories
Note
2003670000
D.9
D
D.10
2003670000
Unregulated power supplies
Electrical cabinet socket outlet
Contents
Electrical cabinet socket outlet
Electrical cabinet socket outlet
Electrical cabinet socket outlet
E.2
E
2003670000
E.1
Electrical cabinet socket outlet
Electrical cabinet socket outlet
Electrical cabinet socket outlet
Schuko TS35
• Simple installation in electrical cabinet
• TS 35 module can be mounted on rail
• VDE mark of conformity
• Two-pole with earthing contact
Technical data
E
Rated voltage
Rated voltage, max.
Rated current
Clamping range, nom.
Tightening torque
Ambient temperature (operational)
Overvoltage category
Pollution degree
Protection degree
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Depth x width x height
Note
Ordering data
230 V
250 V
16 A
1 mm²-1.5 mm²
1.3 Nm
-20...40 °C
II
2
GOSTME25; VDE
mm²
mm
1.5 / 1 / 1.5
/ 76 / 45
Type
Schuko TS35
Qty.
10
Order No.
8734580000
Note
Accessories
Note
E.2
2003670000
Glossary/Technical appendix
Contents
Glossary/Technical appendix
Glossary/Technical appendix
Power Supplies – Overview
W.2
Standards and approvals
W.4
Glossary
W.6
W
2003670000
W.1
Glossary/Technical appendix
Power Supplies – Overview
Power Supplies – Overview
Power supplies are important links in the energy supply
chain of automation systems. Unregulated power supplies
or regulated switched-mode power supplies are at the heart
of every electrical cabinet. 24 V DC has emerged as the
standard control voltage for the supply of electrical subassemblies and systems. But other control voltages are also
required. The correct power supply is a critical factor for the
reliable operation of the supplied components. Thus it must
be chosen with particular attention.
Power supplies from Weidmüller, whether regulated or
unregulated, have proven themselves reliable over many
years in the supply of electrical sub-assemblies and systems.
They perform reliably and safely – even under harsh
industrial conditions – in all sectors of machine construction,
industrial automation, and the power and process industries.
Weidmüller offers custom-fit solutions for practically all of
your requirements:
•
•
•
•
•
•
Unregulated transformer power supplies
Primary switch-mode power supplies
DC/DC converters
Diode modules
UPS control modules
Electronic fusing
How they work
Unregulated power supply units consist of a mains
power transformer that transforms the input voltage into a
different AC voltage. The units then make use of a rectifier
and a filter circuit to smooth out the DC output voltage.
Mains (AC)
Output
Unregulated transformer power supply
Regulated power supply units in the range up to
1,000 W are usually designed as primary switched-mode
power units. The mains AC voltage is then rectified and
transformed in high frequency to the secondary side using
switching transistors and power transformers. This is
followed by the rectifier and filter circuit in order to generate
the DC output voltage. A control circuit compares the
current and voltage on the output side to the specified target
values and then generates a control signal for the switching
transistors. This permits compensation for load changes and
mains voltage fluctuations. As a result, the output voltage
remains stable. These power supply units are increasingly
being operated with DC input voltages (for example,
Weidmüller‘s PRO-M line of switched-mode power supplies).
Controller
Mains (AC/DC)
Output
Switched-mode power supply
W
W.2
2003670000
Glossary/Technical appendix
Power Supplies – Overview
A DC/DC converter is a variation of the classic switched
mode power supply. The switching strategy is similar but
there is no input rectifier. Starting with a specified DC input
voltage, DC/DC converters generate a different DC voltage at
a similar or different level. They are used to adapt different
voltage levels and also for isolating potentials.
Controller
Mains (DC)
Output
DC/DC converter
In use around the globe
Weidmüller‘s power supply units have been designed for
use around the world. They can be used in practically all
applications throughout the world because of their CE label
and many other national and international approvals. Their
wide input voltage ranges and compatibility with various
mains power connections increases their global appeal.
Temperature range
During operation, power supply units generate power
losses. In Weidmüller‘s switched-mode power supplies, the
resulting heat is dispersed using natural air currents only.
The design, which does not make use of a ventilation fan,
is an example of our uncompromised durability standard.
Weidmüller‘s power supply units, depending on the model,
can be used in temperatures ranging from -25 °C to +70 °C.
Compact and efficient design
Weidmüller‘s switched-mode power supplies are extra small
because they take advantage of the above-average degree
of efficiency offered by the latest technologies. The power
supplies from Weidmüller – whether they are book-shaped
with minimised base surface, or variants with reduced height
for use in distributor boxes – always provide the proper costsaving solution.
2003670000
W
W.3
Glossary/Technical appendix
Standards and approvals
W
W.4
Standards and approvals
Standard/Approval
Description
DIN EN 50178
(VDE 0160)
Electronic equipment for use in power installations
DIN EN 60950-1
(VDE 0805-1)
IT Equipment – Safety –
Part 1: General requirements
DIN EN 61558-1
(VDE 0570-1)
Safety of transformers, power supply units, throttles and similar devices
Part 1: General requirements and tests
DIN EN 61558-2-17
(VDE 0570 Part 2-17)
Safety of transformers, power supply units and similar devices
Part 2-17: Special requirements for switch-mode power supply transformers
DIN EN 60204-1
(VDE 0113-1)
Safety of machinery – Electrical equipment of machinery –
Part 1: General requirements
DIN VDE 0100-410
Construction of power installations with rated voltages up to 1,000 V
Part 4: Protective measures
Chapter 41: Protection against electrical shock
DIN EN 61204-1
Power supply units for low voltages, with direct-current-output – properties
DIN EN 60947-1
Low-voltage switching devices – Part 1: General definitions
DIN EN 61140
Protection against electrical shock - common requirements for
facilities and operating equipment
IEC 38
Supplementary notes relating to status of international standards and European
harmonisation of mains voltages 230/400 V
73/23 EWG
Electrical equipment for use within specific voltage limits
(Low Voltage Directive)
2004/108/EG
(89/336 EWG)
Electromagnetic compatibility (EMC Directive)
2006/42/EG
(98/37 EG)
Safety of machines (directive covering mechanical equipment)
UL
Safety approval for the United States market
CSA
Safety approval for the Canadian market
GL
Test specifications for electrical/electronic devices and systems for use in marine technology
UL1310
Class 2 power supplies (limited energy)
UL1604
Electrical equipment for use in dangerous surroundings
2003670000
Glossary/Technical appendix
Standards and approvals
Standard/Approval
Description
SEMI F47
Resistance of electronic devices against voltage drops
2006/95/EG
(72/23/EWG)
Low Voltage Directive
EN 60721-3-2
Classification of surrounding conditions
EN 60664-1
(VDE0110-1)
Insulation coordination for electrical equipment
C22.2 No. 107.1
General standards for power supplies (Canadian standard)
EN 61000-3-2
Limiting of mains voltage harmonic currents
EN 61000-4-x
Interference immunity tests
W
2003670000
W.5
Glossary/Technical appendix
Glossary
Glossary
A
AC/DC converter
Conventional switched-mode power supplies generate a DC voltage from an
AC voltage. For this reason they are sometimes also called AC/DC converters.
Such devices are increasingly compatible for use with DC input voltages.
The primary and secondary sides are typically electrically isolated.
Ambient temperature (operational)
The ambient operating temperature (the min. and max. values) together with
the output current and voltage ratings can be used to describe the power
capabilities of a power supply unit.
B
Burst
C
W
W.6
A burst is a quick low-power burst pulse which can, for example, simulate
welding equipment phenomena. Similar phenomena can also result from
switching operations on the mains supply. This test can be used to demonstrate
immunity against quick transients.
Class of protection
Electrical equipment is classified according to varying classes of protection.
These classes define the particular safety measures that are required to avoid
an electrical shock. The most widely used power supplies correspond with
protection class I. The basic requirement of protection class I is for a basic
insulation and for the earthing of all conductive housing parts. If the basic
insulation fails, then the earthed conductive housing serves to prevent an
electrical shock. For this reason, devices in protection class I are equipped with
an earth (PE) connection.
Connecting power supply units
in parallel
Power supplies can only be connected in parallel when this is clearly permitted
by the manufacturer. Parallel connections are then normally tied to certain
conditions. This is a typical way to increase the output power (for example, when
extending a facility). Power supplies are also wired in parallel in order to design
in redundant power supply systems. The parallel circuit is not wired straight
though but connects using decoupling diodes.
➝ Redundancy
Cooling
Cooling is used by components or devices to prevent them from overheating. A
variety of cooling strategies are available – two of the most common are natural
and forced-air cooling. Natural (convection-based) cooling takes advantage of the
natural air currents. Manufacturers must then ensure that there is sufficient air
flow by specifying the clearance gaps and mounting positions that are required
above and below the ventilation openings. Forced-air cooling normally uses a fan
to dissipate any heat that has been generated. When fans are used in a device,
they have the effect of increasing the likelihood of device outages. For this
reason, a power supply with natural cooling methods is generally preferred.
2003670000
D
Glossary/Technical appendix
Glossary
DC/DC converter
DC/DC converters are switched-mode power supplies that convert a specific
DC voltage into another voltage. They are a variant of the AC/DC converter.
DC/DC converters, in their simplest implementation, do not isolate voltage
potentials. They are used only for adapting voltages. Improved DC/DC converters
have isolated voltages. A safety isolating transformer in the power element
ensures the required electrical isolation. Besides the voltage adaptation, the
isolation of the voltage potentials is an important factor.
Derating
For power supply devices, derating generally refers to the reduction in power as
influenced by the surrounding temperature and the input voltage. A temperature
derating often occurs starting at a surrounding temperature of 50 °C. The rated
power is guaranteed up to this temperature. The available power continually
declines as the temperature heats up above this level. This is typically specified
in %/K. A voltage-dependent specification is another form of derating For
switched-mode power supplies, the derating begins below a specific input
voltage. So a switched-mode power supply with a wide input range can typically
work under full power with 115 V AC input voltage. However at 85 V AC it can
only produce 60 % of the power rating. The coefficient is usually specified in
%/V.
Temperature derating
100
95
90
85
80
75
70
40
45
50
55
60
Temperature [°C]
Diode modules
E
Efficiency
65
Voltage derating
120
Max. current [%IN]
Max. current [%IN]
105
70
75
100
80
60
40
20
0
70
90
110 130 150 170 190 210 230 250 270
Main voltage [V]
Diode modules are used to construct a redundant power supply system. They
are important for decoupling the power supply unit. Thus, a short circuit that
occurs on the output of a power supply unit will not influence the output voltage.
The degree of efficiency is equal to the ratio of output power to input power and
is expressed in percent. The degree of efficiency can be between 70 and 90 %,
depending on the dimensions and type of technology in use.
EMC (electromagnetic compatibility) Electromagnetic compatibility describes the interference emissions caused by an
electronic device and the level of immunity against external electrical influences.
Interference emissions can be caused by cabling and wires or by radiated
emissions. Immunity measures the resistance against such wire-based emissions
and against radiated emissions such as electrostatic fields and magnetic fields.
Electric devices must also be protected against electrostatic discharges.
2003670000
W
W.7
Glossary/Technical appendix
Glossary
F
Foldback characteristic curve
The foldback characteristic curve is a special type of output curve that protects
the power supply unit from overloads. When a specific current limit is exceeded
(for example, by 110 or 120 % of the nominal level), the current is limited
electronically and lowered to a very low, safe value. This downward-sloping
characteristic curve means that it is not sufficient to simply eliminate the
overload. The load must be reduced significantly more so that the adjustment
control can return to the normal voltage control. Thus this solution is not suitable
for many applications and is becoming less popular.
U
UA
INominal I Limit
G
Galvanic isolation
H
Hiccup mode
I
Galvanic (electrical) isolation ensures that no electrical connections can exist
between the primary and the secondary sides. Opto modules and transformers
are the typical components used.
The hiccup mode is a special output characteristic curve that protects power
supply units from overloads and short circuits. The unit switches off at a
specified current limit (for example, 110 or 120 % on the nominal rating) and
then switches back on after a certain delay. This leads to a pulsating mode of
operations which can only revert to continual operations after the overload has
been eliminated. The main disadvantage here is that the connected consumer
load must be restarted after every pause. A restart may not be possible with
motors or large capacitive loads since the restart current peak may once again
exceed the defined limit.
U
UA
W
t
I
ILimit
INominal
t
W.8
2003670000
Glossary/Technical appendix
Glossary
Hold-up time
(mains-failure bridging time)
The hold-up time (also known as the mains-failure bridging time) is the interval
from the start of the mains outage to the point in time when the output voltage
can no longer be maintained at its original level. The hold-up time indicates how
long a mains outage may last before it influences the output voltage. For DC
power supplies, EN 61204 requires a bridging time of at least 20 ms.
U
UA
hold-up time
Power failure
(cutoff)
I
t
Input voltage range
This refers to the minimum and maximum input voltage at which the rated
output specifications can be maintained.
Inrush current
The inrush current refers to the peak current that occurs when turning on a
consumer load. Switched-mode power supplies have storage capacitors in the
input which can cause significant current peaks while the mains power is being
switched on. A variety of circuitry solutions can be used to attenuate these
current peaks. In the simplest solution, an inrush limiter is used. Active switching
can be used in other cases. The peak current specification indicates which
upstream fuse should be used in the circuit. If a fuse is selected which is too
sensitive, it can trigger when the mains power is switched on.
W
2003670000
W.9
Glossary/Technical appendix
Glossary
IU characteristic curve
The IU characteristic curve is a special output characteristic curve that
protects power supply units from overloads and short circuits. It offers the best
performance with regards to overload and short circuit capabilities. A current
limit is activated at a specific current level (for example, 110 or 120 % on the
nominal rating). As the load continues to increase, the output voltage is reduced
according to the current limit curve until it reaches a level approaching zero
volts. Thus a pulsating mode of operations is avoided for short-term overloads.
Large capacitive loads or motors are brought back up along the slope of the
current-limit characteristic curve. After a short circuit or overload is fixed, the IU
characteristic curve offers the advantage of immediately returning to the normal
voltage control mechanism. The full output voltage is then immediately available.
The IU characteristic curve is becoming the established standard for modern
power supplies. Additional variants are available which pertain to the peak
current capacity and the slope of the current-limit characteristic curve.
U
UA
INominal I Limit
M
Mains harmonics
Power supplies can experience harmonics caused by mains rectification on the
input side. These harmonics are multiples of the mains frequencies. Existing
standards define specific limit values since such harmonics can significantly
lower the mains quality.
Mains system types
This refers to the types of mains supply systems. Systems differ in their method
of earthing and the implementation of the phase wire, PE wire and central-point
wire. Common mains systems include the TN, IT and TT networks. The individual
mains types can also differ in their voltage levels and frequencies.
PRO-M
PRO-M
L N PE
TN-S Mains
L1
L2
L3
N
PE
W
W.10
I
MTBF (mean time between failure)
PRO-M
L N PE
TN-C Mains
L1
L2
L3
PEN
PRO-M
L N PE
TT Mains
L1
L2
L3
N
L N PE
IT Mains
L1
L2
L3
N
The MTBF is a statistical value that specifies the probability that a product will
fail. It is typically specified in hours and normally assumes a temperature of
25 °C. The probability of failure depends largely on the ambient surroundings.
The key variables are the type of load and the ambient temperature.
2003670000
O
Glossary/Technical appendix
Glossary
Output characteristic curves
The output characteristic curves of power supply devices are determined by
current and voltage. Unregulated devices do not have a current limit. In the
case of an overload or short circuit, fuses or temperature switches are used to
protect the device. Regulated devices are protected against overload and short
circuits by means of various output characteristic curves. In this case, the system
attempts to prevent any activation of fuses or temperature switches.
The mandatory manual reset which follows an overload or short circuit can then
be avoided. Common output characteristic curves include the hiccup mode, the
foldback characteristic curve or the IU characteristic curve.
➝ Hiccup mode, foldback characteristic curve, IU characteristic curve
Overvoltage category
Power supply units are classified into overvoltage categories according to the
immunity against mains surges and transient voltages.
P
PELV (protective extra-low voltage)
This is a functional DC voltage with secure isolation according to EN 50178. As
with SELV, a reinforced or double insulation is used between the primary and
secondary sides. However, the secondary side is earthed.
PFC (power factor correction)
The power factor correction can be either passive or active in relation to power
supply devices. The reactive power resulting from the bridge rectification puts
a significant strain on the power supply network. The relatively poor power
efficiency factor that results can be improved by using passive components
(such as filters) or an active electronic mechanism. For switched-mode power
supplies, PFC usually refers to the active variant of the power factor correction.
Power factors of almost 1 can be reached when using an active PFC. Practically
no reactive power is drawn from the mains supply network; therefore the strain
on the mains network is relatively low.
Pollution severity
Pollution severity describes the environment and ambient conditions that a
device requires in order for it to function smoothly. Significant environmental
variables include condensation or air containing dust and oil.
Power-boost or boost
The power-boost function is the surge current handling capacity in the seconds
to minutes range. This function is often required for starting up DC motors. DC
motors have a high start-up current and often require several seconds before
they have achieved their rated rotational speed. The power-boost function helps
to optimise this start-up phase.
Power factor
The power factor is the ratio of reactive power to apparent power. It is an
indicator of the device performance with respect to the load on the mains power
network. Depending on the technology in use, the power factor for power
supplies can be between 0.45 and nearly 1.
2003670000
W
W.11
Glossary/Technical appendix
Glossary
Power loss
For power supply units, the power loss specification indicates the thermal
output emitted during nominal (rated) operations. This is a key specification
used by engineers when designing the climate control systems within electrical
cabinets. It is calculated as the difference between the input and output power
and can also take the degree of efficiency into account.
Power rating
The continual output permitted under the rated conditions.
Power supply units connected in
series
Power supplies can only be connected in series when this is clearly permitted
by the manufacturer. Such series connections are then normally tied to certain
conditions. They can be used to increase the output voltage. This is not widely
implemented.
Protection degree
According to DIN EN 60529, devices can be classified according to their
protection degrees. The numeric code (for example, IP 20) defines two
protection degrees: protection against touch or penetration by external objects
(the first digit) and protection against water penetration (the second digit).
Switched-mode power supplies intended for use in electrical cabinets or similar
enclosures are often designed with IP 20 protection. The first digit (in this case,
2) ensures finger protection. The second digit (0) indicates that no protection
against water is provided.
Pulsed current capacity
The pulsed current capacity describes the dynamic performance of a switchedmode power supply. Capacitive consumer loads, with their high inrush currents,
put a particular strain on a switched-mode power supply. Peak values are
reached (in the ms range) which amount to levels many times higher than the
mains current. If the current control mechanism reacts too quickly, this can
lead to voltage drops and can cause problems for loads which are connected in
parallel. For this reason, power supplies are often equipped with a surge current
limiting factor based on time. This allows a high current output for only a few ms
which can be much higher than the rated current.
R
W
W.12
Rated control voltage
The nominal value of the sparkover voltage for the relay.
Rated input voltage
The input voltage required at which, under the normal mains voltage
fluctuations, the output levels can be kept stable. It usually corresponds to the
rated voltage for the electric utility‘s power grid.
Rated output current
The long-term current permitted under the rated conditions.
Rated output voltage
The nominal output voltage used for the rated specifications. It usually
corresponds to the factory default output voltage.
2003670000
Glossary/Technical appendix
Glossary
Redundancy
A power supply system is considered redundant if it is constructed so that it has
partial power supplies which are independent of each other and each of these
can individually deliver the output load. When a fault occurs, therefore, it is still
possible to continue to supply the connected rated load. In reality, at least two
power supplies are connected in parallel using decoupling diodes. In this way, a
short circuit in the output of one power supply will not lead to the failure of the
entire power supply system.
➝ Diode modules
Regulated power supply units
Switched-mode power supplies, as opposed to more common power supply
units, have become established as the standard for the 10–1,000 W power
range. They produce a stable output voltage with minimal residual ripple, even
when influenced by fluctuations in the mains voltage, mains frequency or load.
Their small size and weight is a result of their superior efficiency degree. The
electronic control mechanism typically ensures a constant output voltage that
varies ±1 %.
Residual ripple
The residual ripple describes the ratio of superimposed AC voltage to DC voltage
on the output side of the power supplies. In addition to a percent specification,
the superimposed ripple is often specified in mVSS for switched-mode power
supplies.
Resistance to shock
Resistance to shock refers to mechanical immunity against impacts in any
direction. This is a key factor while the product is being transported.
Response time
The response time is the time that a power supply unit needs to compensate for
a disturbance (for example, a load fluctuation).
S
Switching frequency
Switched-mode power supplies are normally operated with switching
frequencies from 20 to 200 kHz. The HF or power transformer is switched on
an off using transistors at this switching frequency. Small, compact units can be
built with this method in comparison with the traditional 50/60 Hz transformers.
W
2003670000
W.13
Glossary/Technical appendix
Glossary
Switched-mode power supply units
The switching pulse can be either primary or secondary. Thus there are primary
switched-mode and secondary switched-mode power supply units. Secondary
switched-mode power supply units are no longer of much significance. The
primary switched-mode power supplies are now the focus of attention. The
pulse refers to the high-frequency on and off switching of the transformer or
transmitter in order to transmit energy. The high frequency allows the use of
extra small inductive and capacitive components, particularly for the transmitter.
In comparison to transformer-based power supply units, the weight and volume
required are much reduced.
L
+
–
N
PE
Selectivity
When surge protection equipment is connected in series, selectivity refers to the
ability of only one upstream fuse to trigger selectively in the event of an overload.
The differentiation can take into account current or also time. With DC power
supply systems, selectivity refers to the separate fusing of load circuits on the DC
side. In this case as well, only the proper series fuse should trigger in the event
of an overload. Fuses in DC circuits play a critical role since the power supplies
must react to upcoming short circuits with a speedy cut-off or by limiting the
current. Usually electronic fuses are used for this purpose.
Mains
Mains
63 A
25 A
˜
= Power Supplies
16 A
Load
Selectivity for fuses
connected in series
W
W.14
Load Load Load
Selectivity for DC systems
SELV (safety extra low voltage)
SELV refers to extra-low safety voltages according to IEC/EN 60950. Reinforced
or doubled insulation between the primary and secondary sides is used to
prevent electric shock. The output voltage here is sufficiently low so that it does
not pose an injury risk if a person comes into direct contact. Earthing on the
secondary side is possible but not required.
Surge
A surge is a high-power voltage pulse which can be caused by, for example, a
lightning strike. The switching operations from large consumer loads can also
generate such voltage surges on the mains network. The surge test is used to
demonstrate the immunity against high-power voltage pulses.
2003670000
T
Temperature range
U
Unregulated power supply units
V
Vibration resistance
W
Wide-range input
Glossary/Technical appendix
Glossary
The temperature range specifies the minimum and maximum ambient
temperatures for which a device can start up and run continuously.
Unregulated power supplies consist mainly of a transformer, a rectifier and an
Elkos filter. Since no controlling system is in place, mains voltage fluctuations
influence the DC voltage side. Unregulated power supply units are very sturdy;
they can be used in applications where a stabilised DC voltage is not necessary
(for example, power supply to contactors).
Vibration resistance describes the resistance against constant mechanical
vibrations that occur during operations. Rail and ship applications place stricter
demands for vibration resistance on the device.
Modern switched-mode power supplies often feature a wide input range. They
can be run under a wide range of voltages: from min. to max. rated voltages
including the tolerance limits. They do not require any manual range switching.
W
2003670000
W.15
W
W.16
2003670000
Glossary/Technical appendix
Contents
Index
Index
Index
Index Type
X.2
Index Order No.
X.3
Adresses worldwide
X.4
X
2003670000
X.1
Type
C
Index / Type
CP A BATTERY 24V DC1.3AH
CP A BATTERY 24V DC12AH
CP A BATTERY 24V DC17AH
CP A BATTERY 24V DC3.4AH
CP A BATTERY 24V DC7.2AH
CP A WALLADAPTER 30 MM
CP A WALLADAPTER 30 MM
CP A WALLADAPTER 30 MM
CP A WALLADAPTER 45MM
CP A WALLADAPTER 45MM
CP A WALLADAPTER 45MM
CP DC BUFFER 24V 20A
CP DC UPS 24V 20A/10A
CP DC UPS 24V 40A
CP DC UPS TF05
CP DC UPS TF25
CP DCDC 250W 24V 10A
CP DCDC 50W 12V 3A
CP DCDC 50W 15V 3A
CP DCDC 50W 22-24V 2A
CP DCDC 50W 22-24V 2A
CP DCDC 50W 5V 8A
CP DM 10
CP DM 20
CP E SNT 100W 12V 8.5A
CP E SNT 100W 48V 2.3A
CP E SNT 100W 5V 16A
CP E SNT 100W 24V 4.5A
CP E SNT 150W 12V 12.5A
CP E SNT 150W 48V 3.3A
CP E SNT 150W 24V 6.5A
CP E SNT 250W 12V 21A
CP E SNT 250W 24V 10.5A
CP E SNT 250W 48V 5.2A
CP E SNT 25W 12V 2.1A
CP E SNT 25W 24V 1.1A
CP E SNT 25W 48V 0.57A
CP E SNT 25W 5V 5A
CP E SNT 350W 24V 14.6A
CP E SNT 350W 48V 7.3A
CP E SNT 50W 12V 4.2A
CP E SNT 50W 24V 2.2A
CP E SNT 50W 48V 1.1A
CP E SNT 50W 5V 10A
CP E SNT 75W 12V 6A
CP E SNT 75W 24V 3.2A
CP E SNT 75W 48V 1.6A
CP E SNT 75W 5V 12A
CP M CAP
CP M CAP
CP M CAP
CP M DM20
CP M DM20
CP M DM20
CP M DM40
CP M DM40
CP M SNT 250W 24V 10AUW
CP NT 144W 24V 6A
CP NT 192W 24V 8A
CP NT 264W 24V 11A
CP NT 36W 24V 1.5A
CP NT 432W 24V 18A
CP NT 72W 24V 3A
CP NT3 1000W 24V 40A
CP NT3 250W 24V 10A
CP NT3 400W 24V 15A
CP NT3 500W 24V 20A
CP NT3 600W 24V 25A
CP NT3 750W 24V 30A
CP SNT 12W 24V 0.5A
CP SNT 24W 12V 1.5A
CP SNT 24W 15V 1.5A
CP SNT 24W 24V 1A
CP SNT 24W 5V 2A
CP SNT 25W 5V 5A
CP SNT 48W 12V 4A
CP SNT 48W 24V 2A
CP SNT 48W 48V 1A
CP T RM 10
CP T RM 20
CP T SNT 140W 12V 12A
CP T SNT 180W 24V 7,5A
CP T SNT 180W 48V 4A
CP T SNT 360W 24V 15A
CP T SNT 360W 48V 7,5A
CP T SNT 600W 24V 25A
CP T SNT 600W 48V 12,5A
CP T SNT 70W 12V 6A
CP T SNT 90W 24V 3,8A
CP T SNT 90W 24V3,8ACL2
CP T SNT 90W 48V 2A
CP T SNT2 180 W 24 V 7,5 A
CP T SNT2 360 W 24 V 15 A
CP T SNT2 600 W 24 V 25 A
X
X.2
Order No.
1406930000
1251090000
1251110000
1251070000
1251080000
1461870000
1461870000
1461870000
1461850000
1461850000
1461850000
1251220000
1370050010
1370040010
1444480000
1444540000
1313320010
9919372412
9919372415
9919372424
9919371224
9919372405
8710620000
8768650000
1165830000
1165850000
1165820000
1165840000
1165870000
1165890000
1165880000
1202520000
1202530000
1202540000
1202630000
1202620000
1202610000
1202640000
1202550000
1202560000
1202580000
1202450000
1202460000
1202590000
1202480000
1202490000
1202510000
1202470000
1222240000
1222240010
1222240000
1222210000
1222210010
1222210000
1222220000
1222220010
1165480010
8575280000
8575300000
8575310000
8575260000
8575320000
8575270000
8628680000
8628620000
8628630000
8628650000
8628660000
8628670000
9918840024
9928890012
9928890015
9928890024
9928890005
8754960000
8754970000
8739140000
8879230000
1105880000
1105890000
1105440000
1105810000
1105850000
1105820000
1105860000
1105840000
1105870000
1105430000
1105790000
1194410000
1194420000
1194480000
1194490000
1194310000
Page
B.6
B.6
B.7
B.7
B.7
A.13
A.28
B.9
A.13
A.28
B.9
B.8
B.5
B.5
B.9
B.9
A.73
A.69
A.70
A.68
A.68
A.70
A.12
A.12
A.50
A.51
A.50
A.51
A.52
A.53
A.52
A.54
A.54
A.55
A.44
A.45
A.45
A.44
A.56
A.56
A.46
A.47
A.47
A.46
A.48
A.49
A.49
A.48
A.24
A.24
A.72
A.23
A.23
A.72
A.23
A.23
A.27
D.5
D.5
D.6
D.4
D.6
D.4
D.9
D.7
D.7
D.8
D.8
D.9
A.67
A.61
A.60
A.60
A.61
A.62
A.63
A.64
A.65
A.39
A.39
A.31
A.33
A.35
A.33
A.36
A.34
A.36
A.31
A.32
A.32
A.35
A.37
A.37
A.38
Type
M
MTA 30 BK
MTA 30 BK
MTA 30 BK
MTA 30 MF
MTA 30 MF
MTA 30 MF
MTA 45 BK
MTA 45 BK
MTA 45 BK
MTA 45 MF
MTA 45 MF
MTA 45 MF
P
PRO ECO 240W 48V 5A
PRO ECO 480W 48V 10A
PRO ECO 72W 12V 6A
PRO ECO 120W 12V 10A
PRO ECO 120W 24V 5A
PRO ECO 240W 24V 10A
PRO ECO 480W 24V 20A
PRO ECO 72W 24V 3A
PRO ECO 960W 24V 40A
PRO ECO3 120W 24V 5A
PRO ECO3 240W 24V 10A
PRO ECO3 480W 24V 20A
PRO ECO3 960W 24V 40A
PRO MAX 120W 12V 10A
PRO MAX 120W 24V 5A
PRO MAX 180W 24V 7,5A
PRO MAX 240W 24V 10A
PRO MAX 240W 48V 5A
PRO MAX 480W 24V 20A
PRO MAX 480W 48V 10A
PRO MAX 70W 5V 14A
PRO MAX 72W 12V 6A
PRO MAX 72W 24V 3A
PRO MAX 960W 24V 40A
PRO MAX 960W 48V 20A
PRO MAX3 120W 24V 5A
PRO MAX3 240W 24V 10A
PRO MAX3 480W 24V 20A
PRO MAX3 960W 24V 40A
S
Schuko TS35
SDIK PH1
SDIK PH1
SDIK PH1
SDIK PH1
SDIK PH2
SDIS 0.5X3.0X100
SDIS 0.5X3.0X100
SDIS 0.5X3.0X100
SDIS 0.5X3.0X100
SDIS 0.5X3.0X100
SDIS 1.0X5.5X125
SDIS 1.0X5.5X125
SDIS 1.0X5.5X125
SM 18/9.5 K MC NE WS
SM 18/9.5 K MC NE WS
SM 18/9.5 K MC NE WS
SM 18/9.5 K MC NE WS
SM 18/9.5 K MC NE WS
W
WEW 35/1 SW
WEW 35/1 SW
WEW 35/1 SW
WEW 35/1 SW
WEW 35/1 SW
WGS 24Vdc 0.5...5A
WGS 24Vdc 1,6A
WGS 24Vdc 3,15A
WGS 24Vdc 6,3A
WGS 24Vdc 8,0A
WGZ 24Vdc 0.5...5A
WGZ 24Vdc 1,6A
WGZ 24Vdc 3,15A
WGZ 24Vdc 6,3A
WGZ 24Vdc 8,0A
Order No.
Page
1168970000
1168970000
1168970000
1251320000
1251320000
1251320000
1962250000
1962250000
1962250000
1251310000
1251310000
1251310000
A.13
A.28
B.9
A.13
A.28
B.9
A.13
A.28
B.9
A.13
A.28
B.9
1469590000
1469610000
1469570000
1469580000
1469480000
1469490000
1469510000
1469470000
1469520000
1469530000
1469540000
1469550000
1469560000
1478230000
1478110000
1478120000
1478130000
1478240000
1478140000
1478250000
1478210000
1478220000
1478100000
1478150000
1478270000
1478170000
1478180000
1478190000
1478200000
A.9
A.9
A.8
A.8
A.5
A.6
A.6
A.5
A.7
A.10
A.10
A.11
A.11
A.19
A.15
A.16
A.16
A.19
A.17
A.20
A.18
A.18
A.15
A.17
A.20
A.21
A.21
A.22
A.22
8734580000
9008570000
9008570000
9008570000
9008570000
9008580000
9008380000
9008380000
9008380000
9008380000
9008380000
9008410000
9008410000
9008410000
1248580000
1248580000
1248580000
1248580000
1248580000
E.2
A.13
A.28
A.40
A.66
A.40
A.13
A.28
A.40
A.66
B.9
A.28
A.40
B.9
A.13
A.28
A.40
A.66
B.9
1162600000
1162600000
1162600000
1162600000
1162600000
8710270000
8618890000
8618910000
8618930000
8618940000
8727630000
8621040000
8621030000
8621020000
8621010000
A.13
A.28
A.40
A.66
B.9
C.6
C.4
C.4
C.5
C.5
C.6
C.4
C.4
C.5
C.5
2003670000
Type
1100000000
1105430000
1105440000
1105790000
1105810000
1105820000
1105840000
1105850000
1105860000
1105870000
1105880000
1105890000
CP T SNT 70W 12V 6A
CP T SNT 140W 12V 12A
CP T SNT 90W 24V 3,8A
CP T SNT 180W 24V 7,5A
CP T SNT 360W 24V 15A
CP T SNT 600W 24V 25A
CP T SNT 180W 48V 4A
CP T SNT 360W 48V 7,5A
CP T SNT 600W 48V 12,5A
CP T RM 10
CP T RM 20
1160000000
1162600000
1162600000
1162600000
1162600000
1162600000
1165480010
1165820000
1165830000
1165840000
1165850000
1165870000
1165880000
1165890000
1168970000
1168970000
1168970000
WEW 35/1 SW
WEW 35/1 SW
WEW 35/1 SW
WEW 35/1 SW
WEW 35/1 SW
CP M SNT 250W 24V 10AUW
CP E SNT 100W 5V 16A
CP E SNT 100W 12V 8.5A
CP E SNT 100W 24V 4.5A
CP E SNT 100W 48V 2.3A
CP E SNT 150W 12V 12.5A
CP E SNT 150W 24V 6.5A
CP E SNT 150W 48V 3.3A
MTA 30 BK
MTA 30 BK
MTA 30 BK
1190000000
1194310000
1194410000
1194420000
1194480000
1194490000
CP T SNT2 600 W 24 V 25 A
CP T SNT 90W 24V3,8ACL2
CP T SNT 90W 48V 2A
CP T SNT2 180 W 24 V 7,5 A
CP T SNT2 360 W 24 V 15 A
1200000000
1202450000
1202460000
1202470000
1202480000
1202490000
1202510000
1202520000
1202530000
1202540000
1202550000
1202560000
1202580000
1202590000
1202610000
1202620000
1202630000
1202640000
CP E SNT 50W 24V 2.2A
CP E SNT 50W 48V 1.1A
CP E SNT 75W 5V 12A
CP E SNT 75W 12V 6A
CP E SNT 75W 24V 3.2A
CP E SNT 75W 48V 1.6A
CP E SNT 250W 12V 21A
CP E SNT 250W 24V 10.5A
CP E SNT 250W 48V 5.2A
CP E SNT 350W 24V 14.6A
CP E SNT 350W 48V 7.3A
CP E SNT 50W 12V 4.2A
CP E SNT 50W 5V 10A
CP E SNT 25W 48V 0.57A
CP E SNT 25W 24V 1.1A
CP E SNT 25W 12V 2.1A
CP E SNT 25W 5V 5A
1220000000
1222210000
1222210000
1222210010
1222220000
1222220010
1222240000
1222240000
1222240010
CP M DM20
CP M DM20
CP M DM20
CP M DM40
CP M DM40
CP M CAP
CP M CAP
CP M CAP
1240000000
1248580000
1248580000
1248580000
1248580000
1248580000
SM 18/9.5 K MC NE WS
SM 18/9.5 K MC NE WS
SM 18/9.5 K MC NE WS
SM 18/9.5 K MC NE WS
SM 18/9.5 K MC NE WS
1250000000
1251070000
1251080000
1251090000
1251110000
1251220000
1251310000
1251310000
1251310000
1251320000
1251320000
1251320000
CP A BATTERY 24V DC3.4AH
CP A BATTERY 24V DC7.2AH
CP A BATTERY 24V DC12AH
CP A BATTERY 24V DC17AH
CP DC BUFFER 24V 20A
MTA 45 MF
MTA 45 MF
MTA 45 MF
MTA 30 MF
MTA 30 MF
MTA 30 MF
1310000000
1313320010
CP DCDC 250W 24V 10A
2003670000
Page
A.31
A.31
A.32
A.33
A.33
A.34
A.35
A.36
A.36
A.39
A.39
A.13
A.28
A.40
A.66
B.9
A.27
A.50
A.50
A.51
A.51
A.52
A.52
A.53
A.13
A.28
B.9
A.38
A.32
A.35
A.37
A.37
A.47
A.47
A.48
A.48
A.49
A.49
A.54
A.54
A.55
A.56
A.56
A.46
A.46
A.45
A.45
A.44
A.44
A.23
A.72
A.23
A.23
A.23
A.24
A.72
A.24
A.13
A.28
A.40
A.66
B.9
B.7
B.7
B.6
B.7
B.8
A.13
A.28
B.9
A.13
A.28
B.9
A.73
Order No.
Type
1370000000
1370040010
1370050010
CP DC UPS 24V 40A
CP DC UPS 24V 20A/10A
1400000000
1406930000
CP A BATTERY 24V DC1.3AH
1440000000
1444480000
1444540000
CP DC UPS TF05
CP DC UPS TF25
1460000000
1461850000
1461850000
1461850000
1461870000
1461870000
1461870000
1469470000
1469480000
1469490000
1469510000
1469520000
1469530000
1469540000
1469550000
1469560000
1469570000
1469580000
1469590000
1469610000
CP A WALLADAPTER 45MM
CP A WALLADAPTER 45MM
CP A WALLADAPTER 45MM
CP A WALLADAPTER 30 MM
CP A WALLADAPTER 30 MM
CP A WALLADAPTER 30 MM
PRO ECO 72W 24V 3A
PRO ECO 120W 24V 5A
PRO ECO 240W 24V 10A
PRO ECO 480W 24V 20A
PRO ECO 960W 24V 40A
PRO ECO3 120W 24V 5A
PRO ECO3 240W 24V 10A
PRO ECO3 480W 24V 20A
PRO ECO3 960W 24V 40A
PRO ECO 72W 12V 6A
PRO ECO 120W 12V 10A
PRO ECO 240W 48V 5A
PRO ECO 480W 48V 10A
1470000000
1478100000
1478110000
1478120000
1478130000
1478140000
1478150000
1478170000
1478180000
1478190000
1478200000
1478210000
1478220000
1478230000
1478240000
1478250000
1478270000
PRO MAX 72W 24V 3A
PRO MAX 120W 24V 5A
PRO MAX 180W 24V 7,5A
PRO MAX 240W 24V 10A
PRO MAX 480W 24V 20A
PRO MAX 960W 24V 40A
PRO MAX3 120W 24V 5A
PRO MAX3 240W 24V 10A
PRO MAX3 480W 24V 20A
PRO MAX3 960W 24V 40A
PRO MAX 70W 5V 14A
PRO MAX 72W 12V 6A
PRO MAX 120W 12V 10A
PRO MAX 240W 48V 5A
PRO MAX 480W 48V 10A
PRO MAX 960W 48V 20A
1960000000
1962250000
1962250000
1962250000
MTA 45 BK
MTA 45 BK
MTA 45 BK
8570000000
8575260000
8575270000
8575280000
8575300000
8575310000
8575320000
CP NT 36W 24V 1.5A
CP NT 72W 24V 3A
CP NT 144W 24V 6A
CP NT 192W 24V 8A
CP NT 264W 24V 11A
CP NT 432W 24V 18A
8610000000
8618890000
8618910000
8618930000
8618940000
WGS 24Vdc 1,6A
WGS 24Vdc 3,15A
WGS 24Vdc 6,3A
WGS 24Vdc 8,0A
8620000000
8621010000
8621020000
8621030000
8621040000
8628620000
8628630000
8628650000
8628660000
8628670000
8628680000
WGZ 24Vdc 8,0A
WGZ 24Vdc 6,3A
WGZ 24Vdc 3,15A
WGZ 24Vdc 1,6A
CP NT3 250W 24V 10A
CP NT3 400W 24V 15A
CP NT3 500W 24V 20A
CP NT3 600W 24V 25A
CP NT3 750W 24V 30A
CP NT3 1000W 24V 40A
8710000000
8710270000
8710620000
WGS 24Vdc 0.5...5A
CP DM 10
8720000000
8727630000
WGZ 24Vdc 0.5...5A
Page
B.5
B.5
B.6
B.9
B.9
A.13
A.28
B.9
A.13
A.28
B.9
A.5
A.5
A.6
A.6
A.7
A.10
A.10
A.11
A.11
A.8
A.8
A.9
A.9
A.15
A.15
A.16
A.16
A.17
A.17
A.21
A.21
A.22
A.22
A.18
A.18
A.19
A.19
A.20
A.20
Order No.
Type
8730000000
8734580000
8739140000
Schuko TS35
CP SNT 48W 24V 2A
8750000000
8754960000
8754970000
CP SNT 25W 5V 5A
CP SNT 48W 12V 4A
8760000000
8768650000
CP DM 20
8870000000
8879230000
CP SNT 48W 48V 1A
9000000000
9008380000
9008380000
9008380000
9008380000
9008380000
9008410000
9008410000
9008410000
9008570000
9008570000
9008570000
9008570000
9008580000
SDIS 0.5X3.0X100
SDIS 0.5X3.0X100
SDIS 0.5X3.0X100
SDIS 0.5X3.0X100
SDIS 0.5X3.0X100
SDIS 1.0X5.5X125
SDIS 1.0X5.5X125
SDIS 1.0X5.5X125
SDIK PH1
SDIK PH1
SDIK PH1
SDIK PH1
SDIK PH2
9910000000
9918840024
9919371224
9919372405
9919372412
9919372415
9919372424
CP SNT 12W 24V 0.5A
CP DCDC 50W 22-24V 2A
CP DCDC 50W 5V 8A
CP DCDC 50W 12V 3A
CP DCDC 50W 15V 3A
CP DCDC 50W 22-24V 2A
9920000000
9928890005
9928890012
9928890015
9928890024
CP SNT 24W 5V 2A
CP SNT 24W 12V 1.5A
CP SNT 24W 15V 1.5A
CP SNT 24W 24V 1A
Page
E.2
A.64
Index / Order No.
Order No.
A.62
A.63
A.12
A.65
A.13
A.28
A.40
A.66
B.9
A.28
A.40
B.9
A.13
A.28
A.40
A.66
A.40
A.67
A.68
A.70
A.69
A.70
A.68
A.61
A.61
A.60
A.60
A.13
A.28
B.9
D.4
D.4
D.5
D.5
D.6
D.6
C.4
C.4
C.5
C.5
C.5
C.5
C.4
C.4
D.7
D.7
D.8
D.8
D.9
D.9
C.6
A.12
X
C.6
X.3
Addresses worldwide
Addresses worldwide
Let’s connect.
AE
United Arab Emirates
BR
Weidmuller Middle East FZE
Warehouse Q3-79
SAIF-Zone
P.O. BOX 8591
Sharjah
Tel. +971 65572723
Fax +971 65572724
[email protected]
AO
Angola
Please contact
Phambili Interface
South Africa
AR
Argentina
CPI SA
Bauness 2660
C1431DOF Buenos Aires
Tel. +54 11 4523 8008
Fax +54 11 4522 0546
[email protected]
www.cpi.com.ar
AT
AU
AZ
BA
Austria
Weidmüller GmbH
IZ NOE Süd Straße 2b, Obj
M 59
2355 Wiener Neudorf
Tel. +43 2236 67080
Fax +43 2236 6708-899
[email protected]
www.weidmueller.com
Australia
Weidmüller Pty. Ltd.
PO BOX 6944
Huntingwood 2148
Huntingwood Drive 43
Huntingwood NSW 2148
Tel. +61 2 9671 9999
Fax +61 2 9671 9911
[email protected]
www.weidmuller.com.au
Azerbaijan
Representative Office
Rashad Mahmudov
Demirchi Tower, 4th floor
37, Khojali ave.
AZ 1025 Baku
Tel. +994 12 488 80 36
Fax +994 12 488 80 37
rashad.mahmudov@
weidmueller.com
BW
Botswana
Please contact
Phambili Interface
South Africa
BY
Belarus
TECHNIKON Ltd.
Nezavisimosti pr. 177-9
220125 Minsk
Tel. +375 17 393-11-77
Fax +375 17 3930080
[email protected]
CA
CG
CH
CL
Bosnia and Herzegovina
Please contact
our Representative Office
Weidmüller Interface GmbH
& Co. KG
Serbia
BE
Belgium
Weidmüller Benelux B. V.
Mechelsesteenweg 519 bus
6 en 7
1930 Nossegem
Tel. +32 2 752 40 70
Fax +32 2 751 36 06
[email protected]
www.weidmueller.be
BG
Bulgaria
Weid-Bul EOOD
Bul. „Kliment Ohridski“ 13
1756 Sofia
Tel. +359 2 963 2560
Fax +359 2 963 1098
[email protected]
www.weidbul.com
BH
X
X.4
Bahrain
Khayber Trading Company
P.O Box 1976
Manama
Tel. +973 720747
Fax +973 720331
[email protected]
Canada
W Interconnections Canada
Inc.
10 Spy Court
Markham Ontario L3R 5H6
Tel. +1 (905) 475-1507
Ext. 9836
Fax +1 (905) 475-2798
[email protected] www.weidmuller.ca
Congo
Please contact
Phambili Interface
South Africa
CN
CO
CR
CZ
DE
DK
EC
EE
Switzerland
Weidmüller Schweiz AG
Rundbuckstraße 2
8212 Neuhausen am
Rheinfall SH
Tel. +41 52 674 07 07
Fax +41 52 674 07 08
[email protected]
www.weidmueller.ch
Chile
ATS - INTECH
María Luisa Santander 0475
Santiago
Providencia 7500859
Tel. +56 2 341 1271
Fax +56 2 341 1275
[email protected]
www.atsintech.com
CPI CHILE LTDA
Av. Presidente Frei Montalva
6001, 47 complejo el cortijo
Santiago - Conchali
Tel. +562 963 8440
Fax +562 963 8440
[email protected]
www.cpichile.cl
or
BIG electric d.o.o
Mladena Stojanovića 117A
78000 Banja Luka
Tel. +387 51926277
Fax +387 51926277
[email protected]
www.bigelectric.ba
Brazil
Weidmuller Conexel do Brasil
Conexões Elétricas Ltda.
Av. Presidente Juscelino, 642
- Piraporinha
Diadema, São Paulo
09950-370
Tel. +55 (11) 4366-9600
Fax +55 (11) 4362-1677
[email protected]
www.weidmueller.com.br
China
Weidmüller Interface
(Shanghai) Co. Ltd.
100 Yutong Road
25 F, BM Intercontinental
Business Center
200070 Shanghai
Tel. +86 21-22195008
Fax +86 512-68417505
customer.hotline@
weidmueller.com.cn
www.weidmueller.com.cn
w
Colombia
Automatización Avanzada
S. A.
Carrera 97 No., 24 c - 23
Bodega 4
110911 Bogotá-D.C.
Tel. +57 (1) 547-8510
Fax +57 (1) 422-3044
comercial@
automatizacionavanzada.com
www.
automatizacionavanzada.com
Costa Rica
ELVATRON S. A.
la Uruca 400 Norte Banco
Costa Rica
San Jose Costa Rica
Tel. +506 2961-060
Fax +506 5200-609
[email protected]
www.elvatron.com
Czech Republic
Weidmüller s.r.o.
Lomnického 5/1705
140 00 Praha 4
Tel. +420 244 001 400
Fax +420 244 001 499
[email protected]
www.weidmueller.cz
Germany
Weidmüller GmbH & Co. KG
Ohmstraße 9
32758 Detmold
Postfach 30 54
32720 Detmold
Tel. +49 5231 1428-0
Fax +49 5231 14-292083
[email protected]
www.weidmueller.de
Denmark
Weidmüller Danmark
Vallensbækvej 18A
2605 Brøndby
Tel. +45 27747800
[email protected]
www.weidmuller.dk
Ecuador
Elsystec S. A., Electricidad
Sistemas y Tecnología
Vasco de Contreras N35-251
y Mañosca
Quito - Pichincha
Tel. +593 22456510
Fax +593 22456755
[email protected]
Estonia
Please contact
our Representative Office
Weidmüller Interface GmbH
& Co. KG
Latvia
GE
Georgia
Please contact
our Representative Office
Rashad Mahmudov
Azerbaijan.
GH
Ghana
Please contact
Weidmüller Interface GmbH
& Co. KG
South Africa
GR
Greece
G.A. Solutions
Ippokratous 11 Metamorfosi
144 52 Athen
Tel. +30 210 2823233
Fax +30 210 2823233
[email protected]
www.weidmuller.gr
GT
Guatemala
Prestelectro, Prestegard
Electro, S.A.
Avenida Petapa 44-22,
Zona 12
Guatemala City
Tel. +502 2442-3346
Fax +502 2476-8945
[email protected]
HK
HR
or
Soots Interface OÜ
Pärnu mnt 142
11317 Tallinn
Tel. +372 609 6933
Fax [email protected]
www.sootsinterface.ee
EG
ES
FI
Egypt
Standard Electric (OMEGA)
1, Abdelhamid Badawy Street
Heliopolis
Cairo
Tel. +202 21805111
Fax +202 21805600
[email protected]
Spain
Weidmüller, S. A.
Narcis Monturiol 11-13, Pol.
Ind. Sudoeste
8960 Sant Just
Desvern - Barcelona
Tel. +34 934 803 386
Fax +34 933 718 055
[email protected]
www.weidmuller.es
Finland
Weidmüller Suomi,
Weidmüller Aktiebolagetin
sivuliike
Koy Plaza Vivace
Äyritie 8C
FI 1510 Vantaa
Tel. +358 20 7351300
Fax +358 800 114 667
[email protected]
www.weidmuller.fi
FR
France
Weidmüller E. U. R. L.
12, Chaussée Jules César
BP 263 Osny
95523 Cergy-Pontoise Cedex
Tel. +33 1 34 24 55 00
Fax +33 1 34 24 55 01
[email protected]
GB
Great Britain
Weidmüller Ltd.
Klippon House
Centurion Court Office Park,
Meridian East, Meridian
Business Park
Leicester
LE19 1TP
Tel. +44 116 282 3470
Fax +44 116 289 3582
[email protected]
www.weidmuller.co.uk
Hong Kong
Weidmuller (Hong Kong)
Limited Co. Ltd.
Unit 1617, Metropolis Tower
No. 10 Metropolis Drive,
Hunghom, Kowloon
Tel. +852 3154 8088
Fax +852 31548099
[email protected]
Croatia
ElektroPARTNER d.o.o.
Slavonska avenija 24/6
HR-10000 Zagreb
Tel. +385 (1) 6184 793
Fax +385 (1) 6184 795
[email protected]
www.elektropartner.hr
HU
Hungary
Weidmüller Kereskedelmi Kft.
Budapest
Gubacsi út 6.
1097
Tel. +36 1 382 7700
Fax +36 1 382 7701
[email protected]
www.weidmueller.hu
ID
Indonesia
PT. Nego Electrindo
Ruko Mega Grosir Cempaka
Mas Blok I No. 20 – 22
Jakarta 10640
Tel. +62 21 42882255
Fax +62 21 42882266
[email protected]
IE
Ireland
Please contact
Weidmüller Ltd.
Great Britain
IL
Israel
A. U. Shay Ltd.
23/25, Embar Street
49222 Petach-Tikva
P.O. Box 1 00 49
49222 Petach-Tikva
Tel. +972 3-923-3601
Fax +972 3-923-4601
[email protected]
www.uriel-shay.com
ATEKA Ltd.
4, Ha Tavor lane Industrial
area Segula
49691 Petach-Tikva
P.O. Box 4710
Petach-Tikva
Tel. +972 73-200-1311
Fax +972 3-924 4245
[email protected]
www.ateka.co.il
IN
India
Representative Office
Weidmüller Electronics India
Pvt. Ltd.
12th Lane North Avenue, Opp
Joggers Park,
Kalyani Nagar, Pune
411 006
Tel. +91 20-41290090
[email protected]
www.weidmueller.com
IS
Iceland
Samey Automation Center
Lyngas 13
210 Garoabaer
Tel. +354 510 5200
Fax +354 5 10 5201
[email protected]
www.samey.is
IT
Italy
Weidmüller S. r.l.
Via Albert Einstein 4
20092 Cinisello
Balsamo Milano
Tel. +39 02 660681
Fax +39 02 6124945
[email protected]
www.weidmuller.it
JM
Jamaica
Please contact
W Interconnections Inc.
United States
JO
Jordan
Trans Jordan for Electro
PO Box 33 06 07
Amman
Tel. +962 6 533 2020
Fax +962 6 533 5800
[email protected]
JP
Japan
Nihon Weidmüller Co. Ltd.
Sphere Tower Tennoz 2-2-8
Higashi-Shinagawa,
Shinagawa-ku
Tokyo
140-0002
Tel. +81 3 6711 5300
Fax +81 3 6711 5333
weidmullerjapan@weidmuller.
co.jp
www.weidmuller.co.jp
KE
Kenya
Please contact
Phambili Interface
South Africa
KR
Korea
Weidmuller Korea Co. Ltd.
9th floor, Wonbang B/D
Samseong 2-Dong, GangnamGu
Seoul 143-42
Tel. +82 2-516-0003
Fax +82 2-516-0090
[email protected]
www.weidmuller.co.kr
KZ
Kazakhstan
Please contact
OOO Weidmüller
Russia
LT
Lithuania
Please contact
our Representative Office
Weidmüller Interface GmbH
& Co. KG
Latvia
or
ELEKTROS IRANGA
Tinklu g. 29 a
LT-5319 Panevezys
Tel. +370 (45) 582 828
Fax [email protected]
LU
Luxembourg
Please contact
Weidmüller Benelux B. V.
Netherlands
LV
Latvia
SIA Abi4
Daugavgrivas 31b
Riga, LV-1007
Tel. +371 674 70999
Fax +371 676 24562
[email protected]
Representative Office
Weidmüller Interface GmbH
& Co. KG
Udens str. 12-118
Riga, LV-1007
Tel. +371 29254766
Fax +371 674 65637
Ilgonis.rudaks@weidmueller.
com
www.weidmueller.com
2003670000
You can find all Weidmüller addresses and
your local contact on the internet at: www.
weidmueller.com/countries
Addresses worldwide
Sales company
Representation abroad
without representation abroad
Let’s connect.
MD
ME
MG
MK
Moldova
BERHORD A & D srl
79/1, str. Milescu Spartaru
MD-2075 Chisinau
Moldova
Tel. +373 (22) 815002
Fax +373 (22) 815007
[email protected]
www.ad.berhord.com
Montenegro
Please contact
our Representative Office
Weidmüller Interface GmbH
& Co. KG
Serbia.
NL
NO
Madagascar
Please contact
Phambili Interface
South Africa
Macedonia
Please contact
our Representative Office
Weidmüller Interface GmbH
& Co. KG
Serbia
NZ
or
ELEKTRO - SMK dooel
UL. III Makedonska brigada
b.b.
1000 Skopje
Tel. +389 22460295
Fax [email protected]
MT
Malta
E. S. S., Electrical Supplies &
Services Ltd.
San Gwakkin Road
Mriehel
Tel. +356 21255777
Fax +356 21255999
[email protected]
MU
MW
MX
MY
Mauritius
Mubelo Electrical Ltd.
Office 26, Gateway building,
St Jean Road
Quatre Bornes
Mauritius
Tel. +230 4670989
Fax +230 4654051
[email protected]
Malaysia
Connect Plus Technology
Sdn Bhd
No. 43, Jalan PJS 11/22,
Bandar Sunway
46150 Petaling Jaya
Selangor Darul Ehsan
Tel. +60 3 5633 7363
Fax +60 3 5633 6562
[email protected]
www.cptech.com.my
MZ
Mozambique
Please contact
Phambili Interface
South Africa
NA
Namibia
Please contact
Phambili Interface
South Africa
NG
Nigeria
Please contact
Weidmüller Interface GmbH
& Co. KG
South Africa
2003670000
Norway
Sivilingeniør J.F. Knudtzen AS
Billlingstadsletta 97
1396 Billingstad
PO Box 160
1378 Nesbru
Tel. +47 66 98 33 50
Fax +47 66 98 09 55
[email protected]
www.jfknudtzen.no
New Zealand
Cuthbert S. Steward Ltd.
27 Te Puni Street
Petone
PO Box 38496
Wellington Mail Centre 5054
Tel. (04) 568 6156
Fax (09) 489 1752
[email protected]
Cuthbert S. Steward Ltd
4 Fred Thomas Drive
Aon Building, Ground Floor,
South Entry
Takapuna
PO Box 100 338
North Shore City 745
Tel. (09) 489 1751
Fax (04) 568 6056
[email protected]
OM
PE
Malawi
Please contact
Phambili Interface
South Africa
Mexico
W Interconnections S. A.
DE C. V.
Blvd. Hermanos Serdán 698,
Col. San Rafael Oriente
72029 Puebla
Tel. +52 (222) 268 6227
Fax +52 (222) 286 6242
[email protected]
Netherlands
Weidmüller Benelux B. V.
Franciscusweg 221
1216 SE Hilversum
P.O. Box 1505
1200 BM Hilversum
Tel. +31 35 626 12 61
Fax +31 35 623 20 44
[email protected]
www.weidmuller.nl
Oman
DAN INTERNATIONAL LLC.
Ghala St. 111
BP 2901
Seeb
Tel. +968 5036 77
Fax +968 5037 55
[email protected]
Peru
IMPEXINCA S.A.C.
Calle Ortiz de Zevallos No.
105, Urb. San Antonio
18
Lima, Miraflores
Tel. +51 1 447 5608
[email protected]
www.impexinca.pe
J & W CIA. S. A.
Calle 6 Mz. D Lte. 23, Urb.
Ind. Grimanesa
01
Callao
Tel. +51 1 572 2539
Fax +51 1 572 0152
[email protected]
www.jwcia.com
PH
PK
PL
Philippines
Enclosure Systems Specialists
Inc.
2276 Don Chino Roces
Avenue Extension
Room 103/105 Narra Building
1231 Makati City
Tel. +63 2 813 8580
Fax +63 2 813 8596
[email protected]
www.enclosuresystemsph.
com
Pakistan
Automation Controls (Pak)
Apartment No. 33 C III,
Chenab Block, Allama Iqbal
Town
Lahore
Tel. +92 42 37809948
Fax +92 42 37809950
[email protected]
www.acpak.com.pk
Poland
Weidmüller Sp. z. o. o.
ul. Ogrodowa 58
00-876 Warszawa
Tel. +48 22 510 09 40
Fax +48 22 510 09 41
[email protected]
www.weidmuller.pl
PR
Puerto Rico
Please contact
W Interconnections Inc.
United States
PT
Portugal
Weidmüller Sistemas de
Interface S. A.
Estrada Outeiro Polima, R.
Augusto Dias da Silva, Lote
B - Esct. 2
São Domingos de Rana
2785-515 Abóboda
Tel. +351 214 459 191
Fax +351 214 455 871
[email protected]
www.weidmuller.pt
PY
Paraguay
Please contact
CPI SA
Argentina
RO
Romania
Representative Office
Weidmüller Interface GmbH
& Co. KG
Ionescu Crum Street, No.
1, 1st Tower, 1st Floor,
Office 4
500446 Brasov - Brasov
Business Park
Tel. +40 (268) 446 222
Fax +40 (262) 205 410
claudiu.totea@weidmueller.
com
www.weidmueller.com
RS
RU
Serbia
Representative Office
Weidmüller Interface GmbH
& Co. KG
Ustanicka 189, III sprat
lokal 7a
11050 Beograd
Tel. +381 112885274
Fax +381 112885274
zoran.rabrenovic@
weidmueller.com
Russia
OOO Weidmüller
7/10 Khlebozavodskiy
Passage, Moskau
115230
Tel. +7 (495) 771-69-40
Fax +7 (495) 771-69-41
[email protected]
www.weidmueller.ru
SA
Saudi Arabia
Please contact
Weidmuller Middle East FZE
United Arab Emirates
SE
Sweden
Weidmüller AB
Axel Danielssons väg 271
BOX 31025
SE-200 49 Malmö
Tel. +46 77-143 00 44
Fax +46 40-37 48 60
[email protected]
www.weidmuller.se
SG
SI
SK
SV
El Salvador
Prestegard Electro
11 Avenida Norte No. 240
Edificio Salazar No. 2
San Salvador
Tel. +503 2271 1690
Fax +503 2221 3851
[email protected]
SY
Syria
Please contact
Weidmuller Middle East FZE
United Arab Emirates
SZ
Swaziland
Please contact
Phambili Interface
South Africa
TH
Thailand
Pisanu Engineering Co. Ltd.
Kwang Dingaeng, Khet
Dingaeng
800/2 Soi Trakulsuk, Asokedindaeng Road
Dindaeng, Bangkok
10400
Tel. +66 2 248 2896
Fax +662 105 6301
[email protected]
www.pisanu.co.th
TN
Tunisia
Please contact
Weidmüller E. U. R. L.
France
TR
Turkey
Weidmüller Elektronik Ticaret
Ltd. Sirketi
Kavacik Mah. Orhan Veli Kanik
Caddesi 9/1
34810 Beykoz / Istanbul
Tel. +90 (216) 537 10 70
Fax +90 (216) 537 10 77
[email protected]
www.weidmuller.com.tr
TW
Taiwan
Weidmuller (Hong Kong)
Limited
No. 3, Lane 89, ChaungYang
N. Rd
24148 SanChuang City,
Taipei
Tel. +886 921 949 751
[email protected]
TZ
Tanzania
Please contact
Phambili Interface
South Africa
UA
Ukraine
LLC WM UKRAINE
Levanevskogo str. 6
Kiev
3058
Tel. +38 044 490 32 48
Fax
[email protected]
wm-ua.com.ua/
Slovakia
ELEKTRIS s.r.o.
Elektrárenská 1
831 04 Bratislava
Tel. +421 2/4920 0113
Fax +421 2/4920 0119
[email protected]
Vietnam
AUMI Industrial Equipment &
Automation Company Limited
E1, La Thanh Hotel
218 Doi Can Street
Lieu Giai Ward, Ba Dinh
District
Hanoi City
Tel. +84 4 37628601
Fax +84 4 62661391
[email protected]
www.aumi.com.vn
Representative Office
Weidmüller Pte. Ltd.
Level 16 Saigon Tower
Building
29 Le Duan Street
District 1
Ho Chi Minh
Tel. +848 3520 7717
Fax +848 3520 7604
[email protected]
ZA
Representative Office
Weidmüller Pte. Ltd.
37/F, Sathorn Square Building
98 North Sathorn Road
Bangkok, Silom Bangrak
10500
Tel. +66 2 105 6300
Fax +66 2 642 9220
[email protected]
Singapore
Weidmüller Pte. Ltd.
70 Bendemeer Road
# 04-03 Luzerne Building
Singapore 339940
Tel. +65 6841 5311
Fax +65 6841 5377
[email protected]
www.weidmuller.com.sg
Slovenia
Elektrospoji d. o. o.
Stegne 27
SI- 1000 Ljubljana
Osrednjeslovenska
Tel. +386 1 511 3810
Fax +386 1 511 1604
[email protected]
www.elektrospoji.si
VN
South Africa
Phambili Interface
PO Box 193
1609 Johannesburg, Edenvale
5 Bundo Road, Sebenza
1610 Johannesburg
Tel. +27 (11) 4521930
Fax [email protected]
www.weidmuller.co.za
Representative Office
Weidmüller Interface GmbH
& Co. KG
210 Amarand
Avenue, Pegasus Building
181 Pretoria, waterkloof Glen
ext 2 - Tel. +27 12 003 2906
Fax +27 (11) 4526455
Jacques.Vosloo@weidmueller.
com
www.weidmueller.com
ZM
Zambia
Please contact
Phambili Interface
South Africa
ZW
Zimbabwe
Please contact
Phambili Interface
South Africa
Representative Office
Weidmueller Interface GmbH
& Co. KG
Z, office 303
7-D, Zdolbunivska str.
Kiev, 2081
Mobile +38 050 440 25 24
[email protected]
US
UZ
United States
W Interconnections Inc.
821 Southlake Boulevard
Richmond Virginia 23236
Tel. +1 (804) 794-2877
Fax +1 (804) 379-2593
[email protected]
www.weidmuller.com
X
Republic of Uzbekistan
Please contact
OOO Weidmüller
Russia
X.5
Index
We cannot guarantee that there are no mistakes in the
publications or software provided by us to the customer for the
purpose of making orders. We try our best to quickly correct
errors in our printed media.
All orders are based on our general terms of delivery, which can
be reviewed on the websites of our group companies where you
place your order. On demand we can also send the general terms
of delivery to you.
X
X.6
2003670000
Weidmüller – Your partner in Industrial Connectivity
As experienced experts we support our customers and partners around the world
with products, solutions and services in the industrial environment of power,
signal and data. We are at home in their industries and markets and know the
technological challenges of tomorrow. We are therefore continuously developing
innovative, sustainable and useful solutions for their individual needs. Together we
set standards in Industrial Connectivity.
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
32758 Detmold, Germany
T +49 5231 14-0
F +49 5231 14-292083
[email protected]
www.weidmueller.com
Made in Germany
Your local Weidmüller partner can
be found on our website:
www.weidmueller.com/countries
Order number: 2003670000/05/2015/SMKW