AS Series - High Frequency Current Sensors

AS Series • Current Sense Inductors & Transformers
AS Series Current Sensors are designed as a low cost method of
controlling, monitoring or measuring AC currents. The sensors serve as
feedback elements between the output and pulse control circuitry providing
accurate regulation of switch mode power supplies.
Features
• Fully encapsulated for optimal PC board mounting
• Frequency range from 20kHz to 200kHz
• Primary current rating to 30 Amps
• Primary to secondary isolated to 2500 VAC
• Meets VDE norms
• Optimum performance over designated current and
frequency range
• Competitive pricing due to high volume production
• Manufactured in an ISO-9001:2000, TS-16949:2002
and ISO-14001:2004 certified facility
• Fully RoHS compliant
Applications
Isolated current feed-back signal in Switch Mode Power Supplies • Motor current load/overload • Lighting • Switch Controls Ultra-sound current
• High resolution sonar current • Isolated bi-directional current sensor with full wave bridge rectifier
Electrical Specifications at 25°C
Part Number
Prim./Sec.
Ratio
(1)
L sec
(mH Min)
DCR sec
(Ohms Max.)
Sec. Term. (2)
Resistance
(Ohms Nom.)
(3)
I sec
Max.
Volt µS
Max.
AS-100
AS-101
AS-102
AS-103
AS-104
AS-105
AS-110
AS-111
AS-112
AS-113
AS-114
AS-115
1:50
1:100
1:200
1:300
1:500
1:750
1:50CT
1:100CT
1:200CT
1:300CT
1:500CT
1:750CT
5
22
89
200
560
1260
5
22
89
200
560
1260
0.6
1.1
4.5
10.0
25.0
43.0
0.3 / 0.3
0.55 / 0.55
2.25 / 2.25
5.0 / 5.0
12.5 / 12.5
21.5 / 21.5
50
100
200
300
500
750
25 + 25
50 + 50
100 + 100
150 + 150
250 + 250
375 + 375
300mA
150mA
75mA
50mA
30mA
40mA
300mA
150mA
75mA
50mA
30mA
40mA
175
350
700
900
1500
3750
175
350
700
900
1500
3750
(4)
Schematic
1
3
1
2
3
Notes:
1)
17.2
Lsec: Secondary inductance tested at 10kHz and 10mV for 1:50 through 1:500
Prim./Sec. ratios and 1kHz/10mV for Prim./Sec. ratio of 1:750
2)
5.0
This nominal termination resistance value will yield approximately 1.0V
17.0
20.4
of output for each amp of current in a single turn sense line. The output
TALEMA
ASXXX
1
2
3
Voltage/Ampere of these devices can be increased or decreased linearly
over a restricted temperature range by adjusting the terminating resistance.
3)
0.45 x 0.66
4 .0
For Prim./Sec. Ratios of 1:50 through 1:500, the Isec value corresponds to a
6.35
(0.250)
maximum primary current of 15 Amp-turns rms while the Isec value for the ratio of
4)
12.7
1:750 corresponds to a max. primary current of 30 Amp-turns rms.
1
VµS = R t x Is x 2F
Rt (Ohms): Recommended Terminating Resistance
Is (A): Secondary Current
+
9.53
2
+
F (Hz): Frequency
5)
1
3
_
_
Operating Temperature Range: -40°C to +120°C
Primary Sense Current
6) Pin 2 is on Center-Tapped (CT) versions only
THE TALEMA GROUP
•
World Wide Toroidal Specialists
(03-13) AS Series
AS Series • Current -Sense Inductors & Transformers
Electrical Specifications at 25°C
Part Number
Prim./Sec.
Ratio
Lsec (1)
(mHMin.)
D C R sec
(Ohms Max.)
Sec. Term. (2)
Resistance
(Ohms Nom.)
Isec (3)
Max.
Volt µS (4)
Max.
Type 1
Type 2
AS-200
AS-300
1:50
5
0.65
50
300mA
175
AS-201
AS-301
1:100
20
1.30
100
150mA
350
AS-202
AS-302
1:200
80
4.50
200
75mA
700
AS-210
AS-310
1:50CT
5
0.65
25 + 25
300mA
175
AS-211
AS-311
1:100CT
20
1.30
50 + 50
150mA
350
AS-212
AS-312
1:200CT
80
4.50
100 + 100
75mA
700
AS-320
1:50
5
0.65
50
300mA
175
AS-321
1:100
20
1.30
100
150mA
350
AS-322
1:200
80
4.50
200
75mA
700
AS-330
1:50CT
5
0.65
25 + 25
300mA
175
AS-331
1:100CT
20
1.30
50 + 50
150mA
350
AS-332
1:200CT
80
4.50
100 + 100
75mA
700
Type 1
14.50
(0.571)
10.15
(0.400)
3
4
1
17.8
(0.700)
12.7
(0.500)
4.0
(0.157)
5
15.25
(0.600)
3
Pins 1 & 2
Ø 1.30 (0.051)
19.60
(0.772)
Features
• Meets requirements of IEC 950 and VDE norms
UL94, VO recognized materials
• Operating frequency range from 20kHz to 200kHz
Electrical Specifications at 25°C
Pri./Sec.
Ratio
AS-400
1:100
1
350
Switching
AS-401
AS-402
1:100
1:100
2
5
550
1500
Switching
Switching
AS-403
1:100
10
1500
Switching
1:100
1:500
1:500
1:500
50
50
65
80
1500
2700
4200
7500
4
3
1
4
2
5
1
2
6
7
3
5
1
2
6
7
3
4
5
C ase
Type
Schematic
6
7
1
2
Pins 3, 4 &5
Ø 0.80 (0.032)
•
Dimensions
C
D
E
F
G
H
I
Hole
A
17.8
12.8
20.0
10.0
5.0
15.0
5.0
--
2
8
A
B
23.0
32.5
15.5
18.0
25.0
35.5
12.5
15.0
10.0
12.5
20.0
--
5.0
--
---
1
2
3
4
7
A
32.0
20.5
35.0
17.5
12.5
27.5
7.5
--
B
A
A
B
32.5
23.0
27.0
32.5
18.0
15.5
18.0
18.0
35.5
25.0
30.0
35.5
15.0
12.5
15.0
15.0
12.5
10.0
12.5
12.5
-20.0
22.5
--
-5.0
5.0
--
Ø8
Ø5
Ø5
Ø8
8
7
8
Type B
3.5 ±0.3
5.0 ±0.3
7
8
3
4
H
G
I
0.60 x 0.88 mm
(AS-403 0.75 x 1.10)
Pins 1, 2, 6 & 7
Ø 1.30 (0.051)
22.9
17.8
(0.700) (0.902)
7
1
Switching
Switching
Switching
Switching
C
4.0
(0.157)
5
Type A
E
5
• Operating Temperature Range: -40°C to +120°C
• Primary to secondary isolated to 4000 VAC
• Primary current rating to 80 Amps
Volt µS
Application
(Max.)
Part
Number
AS-404
AS-405
AS-406
AS-407
2
17.8
(0.700)
6.35
(0.250)
12.7
(0.500)
Pins 3, 4 &5
Ø 1.00 (0.039)
2
IP
Amps
3
1
Type 2
18.0
(0.709)
5.08
(0.200)
Schematic
1
C
1
2
7
8
G
2
F
D
0.60 x 0.88 mm
E
F
D
1 & 2 Blind Pins for
AS-404 & AS-407
Germany: Int.+49 89 - 841 00-0 • Ireland: Int.+35 374 - 954 8666 • Czech Rep: Int.+420 377 - 338 351 • India: Int.+91 427 - 244 1325