Chiara - Technical details General information Main technical data and reference standards for the devices in the range Component Reference standards Prolonged operation No. changes of position Insulation resistance Breaking capacity or utilization category (MW) >5 1.25 In 40000 for 1 minute (200 changes at In 250V~ CEI 23-5/CEI 23-50/CEI 23-16 2000 at 50Hz of position) 1.25 In cosϕ = 0.6) 10000 (EN 60884-1) for 1 minute (100 changes at In 250V~ CEI 23-9/CEI 23-62 2000 at 50Hz of position) - cosϕ = 0,8) 50000 (EN 60669-1/EN 60669-2-2) for 1 minute CEI 94-4/CEI-EN 61810-1 2000 at 50Hz (EN 60669-1/EN 60669-2-2) for 1 minute Automatic CEI 23-3 2000 at 50Hz MCBs Automatic (EN 60898) CEI 23-95 CEI 23-9 Test voltage withstand (V) 2000 at 50Hz Operating mechanisms CEI 23-9 (EN 60669-1) Socket outlets 5 Basic electrical data* Latching relay Monostable relays RCDs Supports and frames >5 >5 Resistance to abnormal heat and fire Termopressione Glow wire con biglia tests (°C) 125 (°C) 850 125 850 125 850 125 850 a In 250V~ 1.25 In cosϕ = 0,6) 50000 (200 changes at In 250V~ - of position) 1.5...3kA cosϕ = 0,6) 8000 125 850 for 1 minute 2000 at 50Hz - 1.5...3kA 4000 125 850 for 1 minute - - - - 75 650 >5 (EN 60669-1) *For the rated voltages and currents see the specifications for the individual part codes. Clamping capacity of the terminals Flexible wires Min. 0.75 mm² 5/22 Rigid wires Max. 2x4 mm² Min. 0.5 mm² 2CSC600290D0201 | Mylos, Élos, Chiara Cable traction resistance of terminals: > 50N Max. 2x2.5 mm² Adhesion of switches and device to the support: > 0.6J Chiara - Technical details Installation solutions Composition method for devices and supports 5 Installing and removing switches from the support - Frontal installation of the switches on the frame - Modularity of the switches: 22 mm Specifications of screws and terminals – Captive screws with open position captive screws with cross and slot head and clamping plate. – Double input protected terminals for one or two conductors (rigid or flexible). Mylos, Élos, Chiara | 2CSC600290D0201 5/23 Chiara - Technical details Installation solutions Installation on concrete walls No. Modules Screw distance Recommended box 2 (with claws) - 00 050 2 (with screws) 60 mm 00 050 3 83.5 mm 1SL006A00 4 108 mm 00 053 7 100 mm 1SL0064A00 Note: For further information on ABB boxes for concrete walls please refer to the catalog 1SLC001001D0905 - Insulating Enclosures and Installation Materials (see page 5/66) 5 Installation of plasterboard walls No. Modules Screw distance Recommended box 2 (with screws) - 10801/10802/10807 2 (with claws) 60 mm 10801/10802/10807 3 83.5 mm 10804 4 108 mm Ave 254CG, BTicino PS564N, Gewiss GW24245 Vimar V71604 7 100 mm Bticino PS567N Gewiss 24246 Vimar V71606 Note: For further information on ABB boxes for plasterboard walls please refer to the catalog 1SLC001001D0905 - Insulating Enclosures and Installation Materials (see page 5/66). 5/24 2CSC600290D0201 | Mylos, Élos, Chiara Protected installation with IP40/55 wall-mounted enclosures No. Modules IP40 enclosure IP55 enclosure 1 (on 2-module enclosure) 2CSK2140CH 2CSK2155CH 2 2CSK2240CH 2CSK2255CH 3 2CSK2340CH 2CSK2355CH 4 2CSK2440CH 2CSK2455CH The watertight enclosures allow the direct assembly of devices without the aid of supports. The devices are inserted from the rear. See technical details on page 5/57. For further information on IP40/IP55 wall-mounted enclosures, please refer to the catalog 1SLC001001D0905 - Insulating Enclosures and Installation Materials (see page 5/66). 5 IP40 wall-mounted enclosure IP55 wall-mounted enclosure Protected installation with watertight escutcheon plate No. Modules IP55 escutcheon plate 2 (on a square or round box with screws, center 2CSK3255CH distance 60mm) 3 2CSK3355CH Note: The watertight escutcheon plates provide a self-supporting solution that allows direct assembly of devices without the aid of supports. The devices are inserted from the rear. IP55 wall-mounted escutcheon plate Mylos, Élos, Chiara | 2CSC600290D0201 5/25 Chiara - Technical details Installation solutions Installation on raised floors with Undernet under-floor turrets No. Modules Dedicated adapter Undernet tower 5 (max 20 contact blocks) 2CSK1625CH 10900 e 10901 6 (max 12 contact blocks) 2CSK1626CH 10902 e 10903 Note: The dedicated adapter provides a self-supporting solution that allows direct assembly of devices without the aid of supports. The devices are inserted from the rear. The use of finishing plates is not required. For further information on Undernet under-floor turrets, please refer to the catalog 1SLC006001D0903 - Under-floor Distribution Systems (see page 5/66). 5 Installation on surface mounted boxes No. Modules Wall box Frame 2 42 096 Use a 2M self-supporting frame 3 41 823 Use a 3M self-supporting frame 3 41 822 Use a 3M self-supporting frame 4 41 830 Use a 4M self-supporting frame Note: The self-supporting frames allow the direct assembly of devices without the aid of supports. The devices are inserted from the rear. For further information on the wall boxes and duct systems, please refer to the catalog 1SLC800001D0905 - Plastic and Metal Duct Systems (see page 5/66). 5/26 2CSC600290D0201 | Mylos, Élos, Chiara Installation on Lusy table towers No. Modules Lusy tower Frame 4 10 507 Use a 4M self-supporting frame Note: The self-supporting frames allow the direct assembly of devices without the aid of supports. The devices are inserted from the rear. For further information on the Lusy table towers, please refer to the catalog 1SLC006001D0903 - Under-floor Distribution Systems (see page 5/66). 5 Installation sta at o o on DIN rail a adapter No. Modules Dedicated adapter 1 2CSK1608CH 2 2CSK1608CH 3 2CSK1608CH Note: The DIN rail adapter allows devices to be assembled without the aid of supports. The devices are inserted from the front. See technical details on page 5/59. Mylos, Élos, Chiara | 2CSC600290D0201 5/27 Chiara - Technical details Selection of lights Control devices 5 Lamps 2CSK1001CH Single-pole switch, 16A - 250V~ 2CSK1002CH Double-pole switch, 16A - 250V~ 2CSK1004CH Single-pole switch, 16A - 250V~, 2 modules 2CSK1003CH Single-pole two-way switch, 16A - 250V~ 2CSK1007CH Single-pole two-way switch, 16A - 250V~, 2 modules 2CSK1010CH Intermediate switch, 16A - 250V~ 2CSK1008CH Intermediate switch, 16A - 250V~, 2 modules 2CSK1005CH Single-pole push switch NO, 16A 2CSK1016CH Single-pole push switch NC, 16A 2CSK1020CH Single-pole push switch NO with cord pull, 16A with 2.25 m cord Filament 2CSK1021CH Single-pole push switch NC with cord pull, 16A with 2.25 m cord 2CSK1613CH White 2CSK1022CH Single-pole push switch 1 NO and 1 NC, 16A, with ON 230V 2CSK1023CH Single-pole push switch 1 NO and 1 NC, 16A, with OFF symbol 0.4W 2CSK1024CH Single-pole push switch NO, 16A, with red diffuser 2CSK1025CH Single-pole push switch NO, 16A, with green diffuser 2CSK1026CH Single-pole push switch NO, 16A, with orange diffuser 2CSK1027CH Single-pole push switch NO, 16A, with white diffuser 2CSK1028CH Single-pole push switch NO, 16A, with BELL 2CSK1029CH Single-pole push switch NO, 16A, with KEY 2CSK1030CH Single-pole push switch NO, 16A, with STAIR LIGHT 2CSK1031CH Single-pole push switch NO, 16A, with backlit label holder plate 2CSK1032CH Single-pole push switch NO, 16A, with backlit label holder plate, 3 modules Signalling devices Lamps 2CSK1310CH Warning light, ORANGE colour 2CSK1311CH Warning light, WHITE colour 2CSK1312CH Warning light, RED colour 230V 2CSK1313CH Warning light, GREEN colour 0.4W Switch illumination 5/28 2CSC600290D0201 | Mylos, Élos, Chiara Filament 2CSK1613CH White Chiara - Technical details Control devices Switches, two-way switches, intermediate switches and pushbuttons Area of application Control (on and off) of ohmic-inductive loads: Backlighting of the control devices Night-time location - with filament and fluorescent lamps (corrected and uncorrected); - dedicated circuits for powered equipment (aspirators, range hoods, shutters, blinds, fans, etc..) and controllable outlets. To eliminate architectural barriers in creating installations, we recommend the use of luminous controls (Article 4 of Italian Ministerial Decree no. 236 del 14.06.1989). Characteristics - It allows the command key to be identified in the dark. - We recommend the use of white, blue, green or red Chiara lamps. Applications - Bedrooms - Corridors Functional signalling Characteristics - This allows the command key to be identified and the ON/OFF status of a circuit to be signalled in the dark. Technical specifications Rated voltage 250V~ Rated current 10A (16A for pushbuttons) Opening distance of the contacts > 3 mm Dielectric strength > 2000V~ Reference standards LV Directive EN 60669-1. Customization of the control device keys The illuminable keys of the Chiara wiring accessories’ range are supplied with all most widely used functional symbols. Wiring diagrams The diagrams provided below are the most widely applied installation solutions in creating lighting points. Applications - General services of a building complex (entrance halls, stair lights, landings etc.) - Public environments (cinemas, theatres etc.) Signalling with symbols Characteristics - This allows the command key and its specific function to be identified in the dark. Applications - Warehouses, shops, offices - Hotels - Nursing homes, hospitals With warning light Characteristics - Allows the ON/OFF status of an appliance or a lighting circuit, even at a distance. - Visible from both a front and side position. Applications - Signalling the switching on of lighting points outside the environment in which the control device is installed Mylos, Élos, Chiara | 2CSC600290D0201 5/29 5 Chiara - Technical details Control devices Example of functional signalling L L LOAD LOAD N N Warning light on when the switch is OFF (if the switch is in the ON state, the warning light is off while the load is ON). The two warning lights switch on and off respectively when the load is in the OFF and ON state. 5 Example of remote signalling L L LOAD LOAD N N Warning light placed in parallel to the load, of which indicates the ON/OFF state (it is on when the switch is ON). Two warning lights placed in parallel with the load (they switch on and off with it). Instructions for installation in systems with relays and illuminable push switches The lamps must be connected in parallel. Using single-pole latching relays 2CSK1012CH, it is possible to connect up to four fluorescent lamps: by adding a 0.94μF capacitor to the heads of the relay, up to twelve fluorescent lamps can be connected. 5/30 2CSC600290D0201 | Mylos, Élos, Chiara Using double-pole latching relays 2CSK1014CH, it is possible to connect two fluorescent lamps: by adding a 1.41μF capacitor to the heads of the relay, up to twelve fluorescent lamps can be connected. Relays Relay with latching operation for control and adjustment from multiple lamp points by means of single-pole push switches with NO (normally open) contact. Wiring diagrams 2CSK1012CH STEP 1 STEP 2 N Technical specifications Power supply voltage (coil) 230V - 50/60Hz Output contact 2CSK1012CH 1NO / 2CSK1014CH 2NO; 10A (AC1) / 7A (AC15) - 250V~ L 2CSK1014CH STEP 1 Reference standards EN 60669-1, EN 60669-2-2. N 1 STEP 2 3 5 L 2 4 Examples of application The flush-mounted relays of the Chiara wiring accessories’ range can be used to implement numerous functions. The example illustrates a disabled bathroom calling system with cancellation via a key operated push switch: N NC Monostable relay E259 (code M273653) 2CSK1009CH Single-pole push switch, NO, with cord pull NO 2CSK1009CH Double-pole push switch with key control 2CSK1012CH Single-pole latching relay 2CSK1312CH Warning light 2CSK1322CH Buzzer L (230V~) Mylos, Élos, Chiara | 2CSC600290D0201 5/31 Chiara - Technical details Socket outlets Plug sockets Area of application Powering of household appliances, lighting equipment etc. Technical specifications Main features Italian and German standard sockets. The cells of the sockets are segregated and protected when the plug is disconnected: the live parts are accessible only with the corresponding plug fully inserted. Rated voltage 250V~ Rated current 10A o 16A Shuttered and elastic live cells Possibility of coupling Chiara sockets with the various types of plugs on the market 20 ø5 American 2P, 15A 25 = 25 = Schuko 2P+T, 16A ø5 2P+T, 16A ø5 2P, 16A 20 20 20 ø3 5 2P+T, 10A ø3 2P, 2,5A ø3 2P, 10A ø5 ø5 ø5 ø3 ø3 ø3 6mm 1mm Plug sockets, 250V~, Italian standard with safety shutters P 11 Q Q Q 2CSK1101CH P 17 Q Q Q Q 2CSK1102CH P 17/11 Q Q Q 2CSK1103CH Plug sockets, 250V~, Italian/German standard with safety shutters and side/central earth P 30 Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q 2CSK1108CH P 30/17 Q 2CSK1109CH Interlocked socket outlets with automatic MCB P 17/11 2CSK1324CH P 30 Q 2CSK1325CH Special sockets Shaver socket (1) Q 2CSK1113CH (1) Shaver socket, European/American standard with insulating transformer 230V~ - 50/60 Hz Reference standards CEI 23-5, CEI 23-50, CEI 23-16 (IEC 60884-1). Note: In general terms, no plug sockets of any standard for domestic use fall under the European low voltage directive, because there is no harmonized European standard for these types of sockets: in fact, each country has its own standard and therefore a single standard is impossible. For this reason the plug sockets do not bear the CE mark. All the sockets of the Chiara wiring accessories’ range conforming to CEI 23-50 are however are certified by IMQ as a further guarantee of their quality and compliance with standards. 5/32 2CSC600290D0201 | Mylos, Élos, Chiara Plug sockets for dedicated lines Plug sockets for dedicated lines allow outlet points to be differentiated according to their particular application, avoiding incorrect connection of unsupported appliances. Different coloured enclosures (red, orange, green) distinguish them from common power sockets. There are as yet no standard regulations on the correspondence between the colour of the socket and the type of power supply. In order to distinguish the area of application, the following usage customs are adopted. Red: continuous power supply with UPS (uninterruptible power supply) through an insulating transformer. Orange: power supply protected by network-generator unit through an insulating transformer. Green: safety power supply with network/generator unit. 5 Special sockets Description 2P shaver socket with insulating transformer. Power supply 230V~ - Code 2CSK1113CH 50/60Hz. Output voltage 125V~ (American standard 2P socket) or 230V~ (2P socket P11 type) Components Operating pushbutton The socket is suitable for the insertion Italian standard plugs of the P11 type (2P) and American standard plugs (2P). The shaver socket is protected against overload with a thermal interruption device without auto-reclosing. After the protection is tripped, the cells of the socket are not energized. To reclose the circuit, the plug of the device that caused the overload must be disconnected, waiting a few minutes in order to allow the transformer to cool down. Technical specifications Socket for plug P11 type (2P) Power supply 230 V~ 50-60 Hz Output voltage 230 V~ for plugs P11(2P) 2,5 A 120 V~ for plugs 2P 15 A 125 V~ Socket for 2P plug 15A 125V~ American standard The shaver socket incorporates an insulating transformer with a power rating of 20 VA, protected against overload and resistant to short-circuits. Power supply is guaranteed by a pushbutton that is operated automatically whenever the plug is inserted in the socket. The secondary circuit, to which the cells of the socket are connected, is isolated from the primary power supply circuit by double insulation: additional protections (shutter devices) on the cells of the socket are therefore superfluous. American standard with nonAvailable power polarized flat pins 20VA Operation with auto-protected temperature Reference standards EN 61558-2-5, EN 61000-3-2, EN 55014-1, EN 55014-2. Mylos, Élos, Chiara | 2CSC600290D0201 5/33 Chiara - Technical details Socket outlets Description Code Flush-mounted USB charger 500-650mA, with male type A connector, 2CSK1160CH power supply 230~ 50/60Hz, output voltage 5V DC Components Power supply terminals USB connector type A - female Power supply terminals 5 The flush-mounted USB charger allows you supply and recharge the most common portable electronic devices. Using only a USB cable with Type A male connector it is possible to power mobile phones, smartphones, tablets and cameras that support standard USB power supply (up to 650mA), independently of the manufacturer. Operating method Connect the USB cable with the type A male connector to the charger and the opposite end to the device to be powered. Type A, B, miniUSB and microUSB USB connectors can be used indifferently. The device is now being charged. Caution: the device supplies power according to the USB data transmission protocol, with a maximum current of . Some devices may require a higher power 650mA at 5V supply current. Look up the manual of the connected device to check its absorption specifications. The charging time depends on the connected device and may vary compared with the original charger. Examples of application USB cable with type A male. Wiring diagrams L N Caution! The device absorbs up to 60mW in the absence of connected electronic devices. To exclude this absorption, it is recommended to use a double-pole switch. Technical specifications Power supply 125-250V - 50/60 Hz Input current 5A 230V Output current 500-650mA at 5V DC Max absorption in standby 60mW Operating temperature -20 +50°C Storage temperature -20 +80°C Protection class IP20 Place of use indoors, dry The device is protected against short-circuits by an internal fuse (not replaceable). 5/34 2CSC600290D0201 | Mylos, Élos, Chiara Interlocked socket outlets Description 2P+E socket outlet, 16A - 250V~, interlocked with MCB, P17/11 Code 2CSK1324CH 2P+E socket outlet, 16A - 250V~, interlocked with MCB, P30 2CSK1325CH 2P+E socket outlet, 16A - 250V~, with RCD 10mA, P17/11 2CSK1326CH Components Interlocked socket outlets with automatic MCB (PIA) Socket Manual reset control Indication of the Characteristic curve Interlocked socket outlets with automatic MCD (PID) Socket - terminal user devices in rooms where there is a greater risk of electrocution (bathrooms, showers, etc.) - sockets that power class 1 users with electronic circuits - sockets for portable user devices in domestic or similar environments (irons, drills, etc.). Operation The MCB or RCD interlocked with the socket energises the cells of the socket only after the plug has been inserted and automatically cuts off voltage to the socket before the plug is fully extracted. Therefore the plug is always inserted and extracted without an electrical arc. The lever of the circuit-breaker can be closed only after the plug is inserted; without the plug, the lever operates without effect and does not close the switch. Current-time tripping diagrams for circuit-breakers of the Chiara range 300 200 Normal operation signal 100 80 60 40 Manual reset control 20 Interlocked socket outlets with automatic RCD (PID). These sockets are suitable for installation in the system terminations for protection of the load supplied from the outlet against dangers of short circuits and overloads, as well as protection of the user against contact voltages. The residual current function with sensitivity of 10 mA also acts in the presence of non-sinusoidal fault currents (alternating currents mixed with unidirectional pulsating currents). In compliance with installation standards, they are particularly suitable for the protection of: 10 8 6 4 2 1 SECONDS Interlocked socket outlets with automatic MCB (PIA) These sockets are suitable for installation in the system terminations for protection of the load supplied from the outlet against dangers of short circuits and overloads.. MINUTES Indication of the Characteristic curve 40 20 10 8 6 4 2 1 0,8 0,6 0,4 0,2 0,1 0,08 0,06 0,04 0,02 0,01 1 1.11.2 1.5 2 2.5 3 4 5 6 7 8 9 10 11 12 MULTIPLES OF RATED CURRENT In Mylos, Élos, Chiara | 2CSC600290D0201 5/35 5 Chiara - Technical details Socket outlets Technical specifications Wiring diagrams Power supply voltage 230 V~ - 50 Hz Residual current (sensitivity) IΔn 10 mA Operation dependent on the line voltage they must be installed downstream of a general residual current circuitbreaker Thermomagnetic tripping 2CSK1324CH 2CSK1325CH with characteristic C Double-pole isolation with 1 protected pole Breaking capacity 3000 A Rated current corresponding to the standard of the socket 5 Type A RCBO for alternating and unidirectional pulsating currents Front LED with green light indicates normal operation with the presence of network power supply and contact closed 2CSK1326CH 5/36 2CSC600290D0201 | Mylos, Élos, Chiara Reference standards: Interlocked socket outlets with MCB: LV Directive, Standard CEI 23-97. Interlocked socket outlets with RCD: LV Directive, Standard CEI 23-96. TV/SAT sockets The TV/SAT coaxial sockets for the Chiara series offer a complete range of products for implementing the terminal part of modern antenna systems. Manufactured fully from die cast Zama, they include a pressure terminal with safety screw in order to guarantee proper grip of the cable. Individual sockets are available with male IEC or female F bushing, and double demixed sockets with both connection possibilities. Various levels of attenuation are available, ensuring that solutions are available for every type of installation. Components F female connector Coaxial cable housing IEC male connector TV/SAT coaxial sockets Double demixed TV/SAT coaxial sockets Attenuation values of the TV/SAT coaxial sockets Code Bushing Passing attenuation [dB] 5÷40 47÷862 MHz MHz 950÷2402 Bridging attenuation [dB] 5÷40 47÷862 950÷2400 MHz MHz MHz MHz Inverse attenuation Direct current transit [dB] 2CSK1117CH Male IEC Terr. - - - 0,5 0,5 0,5 - NO 2CSK1118CH Male IEC Terr. - - - 0,5 0,5 0,5 - YES 2CSK1132CH Male IEC Terr. ≤2 ≤2 ≤3 ≤7 ≤7 ≤8 ≥35 NO 2CSK1136CH Male IEC Terr. ≤2 ≤2 ≤2,5 ≤10,5 ≤10 ≤11 ≥35 NO NO 2CSK1137CH Male IEC Terr. ≤1,5 ≤1,5 ≤2,5 ≤14,5 ≤14 ≤14,5 ≥35 2CSK1138CH Male IEC Terr. ≤1,5 ≤1,5 ≤2,5 ≤18,5 ≤18 ≤18,5 ≥35 NO 2CSK1119CH Female SAT - - - ≤0,5 ≤0,5 0,5 - YES Attenuation values of double demixed TV/SAT coaxial sockets Code Bushing Passing attenuation [dB] TV SAT Bridging attenuation [dB] TV SAT Inverse attenuation [dB] Direct current transit 2CSK1133CH Male IEC Terr. Female SAT Male IEC Terr. Female SAT Male IEC Terr. Female SAT Male IEC Terr. Female SAT Male IEC Terr. Female SAT - - ≤2 ≤2 - YES ≤4 ≤5 ≤6,5 ≤7 ≥35 YES ≤3 ≤4,5 ≤10 ≤11 ≥35 YES ≤2 ≤3 ≤14 ≤15 ≥35 YES ≤1 ≤2 ≤18 ≤19 ≥35 YES 2CSK1120CH 2CSK1132CH 2CSK1131CH 2CSK1139CH Mylos, Élos, Chiara | 2CSC600290D0201 5/37 5 Chiara - Technical details Socket outlets Instructions for installation 5 ø5 mm 5-7 mm 2CSK1130CH 2CSK1131CH 2CSK1132CH 2CSK1135CH 2CSK1136CH 2CSK1137CH 2CSK1138CH 2CSK1139CH 10 mm 2 mm 5-7 mm Technical specifications Manufactured from die cast Zama. Pressure terminal. Available with bushing of type: male CEI, female F. Reference standards EN 50083-1, EN 50083-2, EN 50083-4 5/38 2CSK1117CH 2CSK1118CH 2CSK1119CH 2CSK1133CH 7 mm ø7 mm Direct socket 10 mm 2 mm Feedthrough socket converted to terminal socket Feedthrough socket 2CSC600290D0201 | Mylos, Élos, Chiara Closing terminal resistance 75ohm 2CSE1610EL 8CH 9CH Wiring diagrams TV TV/SAT TV system with branched sockets from the central unit TV/SAT system with feedthrough demixed sockets from the central unit TV/SAT system with branched demixed sockets from the central unit 2CSK1139CH 2CSK1133CH 2CSK1137CH 2CSK1131CH 2CSK1133CH 2CSK1136CH 2CSK1130CH 2CSK1133CH 2CSK1118CH 2CSK1132CH 2CSK1120CH 2CSK1133CH Closing resistance 75ohm Closing resistance 75ohm Closing resistance 75ohm Closing resistance 75ohm 2CSK1118CH TV system with feedthrough sockets from the central unit 2CSK1138CH 2CSK1118CH 2CSK1118CH 2CSK1118CH 5 TV/SAT Mixed TV/SAT system, single consumer Multiswitch radial TV/SAT system SAT system, single consumer Terr. amplifier 220V TV amplifier MIX TV/SAT 2CSK1133CH 2CSK1133CH 2CSK1133CH SAT decoder 2CSK1133CH SAT SAT system, single consumer SAT and feedthrough Multiswitch system SAT and radial Multiswitch system 220V 2CSK1139CH 2CSK1139CH 2CSK1139CH SAT decoder 2CSK1119CH Mylos, Élos, Chiara | 2CSC600290D0201 5/39 Chiara - Technical details Socket outlets Network and telephone sockets The range includes devices for the implementation of telephone and computer networks, RJ11 4-contact telephone connectors for telephones, telefax, modems and RJ12 6-contact telephone connectors for intercommunicating telephone installations. RJ45 category 5e and 6 connectors are also available. These devices allow computer equipment (computers, modems, printers, etc) to be connected in a network and connection of multimedia devices. 5 Components Adapter for connector RJ connector RJ connector Adapter for connector Code Connector type No. contacts Cable type Shielded Category Speed 2CSK1121CH RJ11 4 twin core NO 3 up to 16 Mb/s 2CSK1122CH RJ12 6 twin core NO 3 up to 16 Mb/s 2CSK1124CH RJ45 8 UTP NO 5e up to 100 Mb/s 2CSK1125CH RJ45 8 FTP YES 5e up to 100 Mb/s 2CSK1127CH RJ45 8 UTP NO 6 up to 10 Mb/s 2CSK1128CH RJ45 8 FTP YES 6 up to 10 Mb/s FTP = cable shielded with aluminium tape UTP = unshielded cable Instructions for installation Unshielded connectors: 1. wire the connector making sure that the connection terminals match; 2. operate the lever wiring device on the connector; 3. latch the connector on the adapter and proceed with the installation on the frame. Shielded connectors: 1. wire the connector making sure that the connection terminals match; 2. position the cover of the connector and squeeze with pliers to make sure the contacts are tight; 3. apply the shielding, ensuring insulation of the connector; 4. latch the connector on the adapter and proceed with the installation on the support. A 2 1 Keystone adapter 2CSK1135CH: the structured wiring systems for data transmission are distinguished by their flexibility of use, installation independent of location and the use of the terminal outputs. The suppliers of components for wiring, when dealing with installations of a certain complexity and size, must be in able to show certification of conformity of the installation, directly or through accredited installations. ABB meets this requirement with the adapter of the Chiara wiring accessories’ range, which is compatible with various Keystone coupling connectors available on the market and enables integration between the Chiara wiring accessories’ range and data transmission components of systems with structured wiring. 1. latch the connector on the adapter and proceed with the installation on the frame. 3 5 B A 2 1 Unshielded connectors 5/40 2CSC600290D0201 | Mylos, Élos, Chiara Shielded connectors 4 5 B Keystone adapter 2CSK1135CH Wiring diagrams for RJ11 and RJ12 telephone connectors RJ11 Wiring diagrams for RJ45 data connectors To obtain the EIA/TIA 568A or 568B configuration included below, follow the colour code shown on the terminal box. RJ12 568A 2345 568B 123456 12345678 12345678 2 3 4 5 1 2 3 4 5 6 5 For telephone use, 2 wires of the telephone connectors, use the central contacts 3-4 Connection in series 568A connect pin 2 3 4 5 connect pin 2 3 4 5 2 8 connect pin 2 3 4 5 568B L1 A 3 5 6 4 A B Terminals 3 and 4 are connected via the internal contact to the telephone (closed with the receiver hung up). Lifting the receiver causes interruption of the downstream line (L1), guaranteeing secrecy of the conversation. B 7 1 Telephone pair L2 Connection in parallel 60 mm 5 mm connect pin 2 3 4 5 connect pin 2 3 4 5 connect pin 2 3 4 5 L1 Telephone pair L2 Each socket captures the line signal (there is no secrecy of conversation). 2345 Note: extracting one of the plugs causes disconnection of sockets located downstream. In order to prevent this, you just need to insert a plug in the socket from which the telephone device was removed with a jumper between terminal 3 and 4. Technical specifications Connections With perforated insulation Conductors non-butted, inserted in the appropriate blade slots Reference standards EN 50083-1, EN 50083-2, EN 50083-4, ISO 11801. Mylos, Élos, Chiara | 2CSC600290D0201 5/41 Chiara - Technical details Protection devices Fuse holders and overvoltage limiters Description Fuse holder, for fuses Ø5x20 / Ø6.3x32 mm, max. 16A Code 2CSK1301CH Components Removable cover for removal of the fuse 5 Replacement fuses Fuses with dimension Ø5x20mm or Ø6.3x32 mm can be installed. The use of the fuses on page 4/23 is recommended. 5/42 2CSC600290D0201 | Mylos, Élos, Chiara Replacement of the fuse After removing the removable cover with a screwdriver, proceed with replacement as in the drawing: Description Overvoltage limiter, 75J, 230V~ Code 2CSK1315CH Components Examples of application Over-voltages in domestic networks can be caused both by atmospheric interference and by control, operation or programming of connected inductive loads (air conditioners, burner motors, water pumps, reactors of fluorescent or discharge lamps, washing machines, etc.). Removable cover 5 Signalling LED This device provides protection for power supply sockets for all types of household appliances and in particular for those containing electronic components (Hi-Fi, TV, computers, video recorders, programming mechanisms, cash registers etc.) from damage caused by over-voltages present in power supply networks. Wiring diagram Instructions for installation and operation The protection device is housed in the removable front cover. To replace it, after disconnecting the voltage from the installation, extract the cover from the limiter and separate the SPD block from the plastic cover, levering it with a screwdriver. Replace it with spare part 2CSY1302MY. L N Technical specifications Functions When the red warning light is on, it indicates that the protection has tripped and needs to be replaced (the load remains energised but it is not protected). Residual current limiting protection (line-to-neutral) Rated voltage (Un) 120-230 V~ 50/60 Hz Number of ports 1 Rated load current IL 16 A Tensione max continuativa (Uc) 250 V~ Test class III Protection level (Up) < 1,2 kV Test voltage of combined wave 2,5 kV generator Uoc Rated flashover current (In) 1 kA (8/20 ns) 20 times Max flashover current (Imax) 2 kA (8/20 ns) once Temperature range -5 °C - +40 °C Internal integrated protection fuse Reference standards LV Directive, Standard EN 61643-11 Mylos, Élos, Chiara | 2CSC600290D0201 5/43 Chiara - Technical details Protection devices Miniature circuit-breakers and Residual current circuit-breakers Description Automatic MCB, 1P+N, C6, breaking capacity 1.5kA 5 Code 2CSK1304CH Automatic MCB, 1P+N, C10, breaking capacity 3kA 2CSK1305CH Automatic MCB, 1P+N, C16, breaking capacity 3kA 2CSK1306CH Automatic RCD, 1P+N, C6 - 10 mA, breaking capacity 1.5kA 2CSK1307CH Automatic RCD, 1P+N, C10 - 10 mA, breaking capacity 3kA 2CSK1308CH Automatic RCD, 1P+N, C16 - 10 mA, breaking capacity 3kA 2CSK1309CH Automatic RCD, 1P+N, C6 - 30 mA, breaking capacity 1.5kA 2CSK1328CH Automatic RCD, 1P+N, C10 - 30 mA, breaking capacity 3kA 2CSK1329CH Automatic RCD, 1P+N, C16 - 30 mA, breaking capacity 3kA 2CSK1330CH Components Automatic RCD Normal operation signal – Manual reset control Test key (TEST) Indication of the Characteristic curve – Automatic MCB – Manual reset control Indication of the Characteristic curve – – Automatic MCBs and automatic RCDs provide protection against over-currents and earth fault currents of terminal circuits. Protection class with the device embedded in smooth vertical walls with the associated support, frame and blank covers, if required: IP41. Instructions for installation and operation Use in dry and dust-free locations. – Temperature between -5 °C and +40 °C.. – Suitability for installation on the supply side of a socket or device for the protection against overloads and short circuits of the equipment and, at the same time, for protection of the users against contact voltages. – The sensitivity (operating residual current) of 10mA and 5/44 2CSC600290D0201 | Mylos, Élos, Chiara – – – the suitability for operation also in the presence of nonsinusoidal fault currents (alternating currents mixed with unidirectional pulsating currents) allow the protection devices of the Chiara range to be classified as “type A RCBOs” (identified by the symbol), particularly suitable for the protection of: • terminal uses in rooms where there is a greater risk of electrocution (bathrooms, showers, kitchens etc.), as prescribed by the CEI standards; • class I consumer power sockets with electronic circuits (computers and accessories, electronic scales, electronic typewriters, cash registers etc.). In domestic and service industry networks non-sinusoidal fault currents are often present because of the use of electronic boards in domestic appliances. The electromagnetic part of the circuit breakers guarantees protection against overloads and short circuits; the residual current part of the devices, for current values of 10mA, guarantees protection of persons against the contact voltages. Closing the circuit: manually press the lever of the circuit breaker at the “I” symbol. Opening the circuit: • manually, by pressing the lever of the circuit breaker at the “0” symbol or the yellow test button (test); • automatically, due to thermal (overload), magnetic (short-circuit) or residual current (earth fault current) tripping. The device must not be used as a control breaker. To check that the circuit breaker is installed and behaving correctly, the yellow test button (test) must be pressed every month. If the device is correctly installed and powered, the circuit breaker trips; if it does not, you must immediately inform the installation technician because safety will be compromised. After the test, you need to press the main key near the “I” symbol in order to reset the circuit breaker. Thermomagnetic tripping with characteristic “C” (see the current-time tripping diagram provided below). Double-pole operation with one protected pole + N, type A for alternated fault currents and unidirectional pushbuttons. Operating residual current (sensitivity) IΔn 10mA; the circuit breaker must be connected according to the electrical diagram provided below. The supply line can be connected to either the upper or the lower terminals of the circuit breaker, which must be installed downstream of a general residual current circuit breaker (Standard CEI 64-8/5, paragraph 532.2.2.2). The line voltage determines operation (Standard IEC 1009-1, paragraph 4.1.2). 10000000 1000000 Specific through energy I2t 100000 C13 C16 C10 C13 C6 C13 10000 5 1000 100 10 1 10 100 1000 1500 Short circuit current Current-time tripping diagrams for circuit-breakers of the Chiara range 300 200 100 80 60 40 20 MINUTES Characteristics – Main lever operated control part: “I” symbol (closed circuit); “0” symbol (open circuit). – Front LED for signalling the presence of line voltage and closed circuit. – Yellow test button (test) for checking that the device is functioning properly. – Terminals protected with captive screws for clamping two conductors up to 4 mm 2 each – Construction of the thermo magnetic part as prescribed by Standards EN 60898 and IEC 60898. – Construction of the residual current part according to Standards EN 61009 and IEC 61009. – Power supply voltage: 120-230V~ ±10% 50-60Hz. Characteristic curves 10 8 6 4 2 1 SECONDS Functions – Green front LED for signalling normal operation: presence of line voltage and closed circuit. – Internal temperature checking: the circuit breaker automatically operates the opening of the circuit as soon as the safety threshold is exceeded. – Self-test function to check the electrical continuity of the internal residual current circuit (in the absence of continuity, the circuit breaker will open). – Opening the circuit if voltages occur higher than the predefined threshold at the circuit breaker input(for example, in 380V~ three-phase systems the circuit breaker prevents an erroneous “line-to line ” connections, instead of “line-to-neutral”). 40 20 10 8 6 4 2 1 0,8 0,6 0,4 Wiring diagram 0,2 0,1 0,08 0,06 0,04 0,02 0,01 1 1.11.2 1.5 2 2.5 3 4 5 6 7 8 9 10 11 12 MULTIPLES OF RATED CURRENT In DEVICES DEVICES Mylos, Élos, Chiara | 2CSC600290D0201 5/45 Chiara - Technical details Protection devices Examples of application 5 Technical specifications Type of circuit breaker MCB Rated voltage 230V RCD 230V Rated frequency 50 ÷ 60Hz 50 ÷ 60Hz Rated residual current - 10mA or 30mA 6A 1500A 6A 1500A 10A 3000A 10A 3000A Correnti nominali 16A 3000A 6 -10 -16A 16A 3000A 6 -10 -16A Number of poles 1P + N 1P + N - Overcurrent protection Type C Type C - Limitation class 3 3 - Residual current protection - Class A Short-circuit breaking capacity Tripping characteristic Reference standards Thermomagnetic: EN 60898-1 - Differential: IEC 61009-1 5/46 2CSC600290D0201 | Mylos, Élos, Chiara Chiara - Technical details Safety and comfort devices Thermostats and time-programmed thermostats Description Summer/winter electronic thermostat, relay output, Code 2CSK1202CH 1 contact NO 8A (AC1)/2A (AC15) - Power supply 230V~ 50/60Hz Components Current value of the AMBIENT TEMPERATURE in °C. While adjusting the value of the DESIRED TEMPERATURE, it value is displayed (flashing). About 5 seconds after the last time the keys were pressed, it returns to displaying the AMBIENT TEMPERATURE. Display indicating the value of the DESIRED TEMPERATURE RELAY ENERGISED icon. This icon is displayed when power is requested from the system controlled by the thermostat. ) The type of icon displayed ( or depends on the operating mode of the thermostat (heating or air conditioning). Key to INCREASE the DESIRED TEMPERATURE (in steps of 0.5°C). The maximum value that can be set is 30 °C. Key to DECREASE the DESIRED TEMPERATURE (in steps of 0.5 °C) The minimum value that can be set is 5.0 °C (anti-freeze temperature) ANTI-FREEZE icon. This is displayed when the DESIRED TEMPERATURE is set to the minimum value (5.0 °C) The electronic thermostats of the Chiara series are equipped with a summer/winter switch for heating and air conditioning systems. Characteristics - Display of the current ambient temperature - Display of the comfort temperature - Display of the night-time temperature set - Possibility to increase or decrease of temperature in steps of 0.5°C - Minimum configurable value that can be set 5°C (anti-freeze temperature) and maximum configurable value 30°C - Display of the operating status of the thermostat by means of symbols - Anti-freeze function set to 5°C Instructions for installation and operation For correct operation, the thermostat must be installed at a height of approximately 1.5 metres from the floor, on internal walls, protected from direct sunlight and from any thermal interference such as heaters, lamps, televisions or any object that generates heat. This device for controlling heating or air conditioning systems, uses a special technique that allows greater stability of the ambient temperature to be achieved while guaranteeing better comfort. Areas of application The environmental thermostats can be used for both heating and conditioning systems to control burners, pumps, valves, and refrigeration compressors. Wiring diagrams L N 230V~ Contact Technical specifications Power supply 230V~ ±15% - 50Hz Consumption < 0.5 W Output Clean contact of 8A resistive relay Operating temperature from 0°C to +50°C Adjustment range from +5°C to +30°C Precision ±1°C Area of use heating and air conditioning Type of adjustment PI Proportional band 2.5°C Reference standards EN60730-1, EN60730-2-9, EN61000-3-2, EN61000-3-3, EN55014-1,EN55014-2 Mylos, Élos, Chiara | 2CSC600290D0201 5/47 5 Chiara - Technical details Safety and comfort devices Description Summer/winter electronic time-programmed thermostat with Code 2CSK1201CH 4 temperature levels, relay output, 1 NO/NC change-over contact 8A (AC1)/2A (AC15) - Power supply 230V~ 50/60Hz Components Temperature levels Ambient temperature detected Pushbuttons for selecting the temperature levels 5 Summer/winter switching Diagram of the set temperature Setting pushbuttons Used in heating and air conditioning systems, the electronic time-programmed thermostats of the Chiara series include the possibility of summer/winter switching and the choice four levels of temperature: comfort, activity, reduction and anti-freeze. Each level is already preset in the memory of the device according to specific standards, that can be modified with the maximum simplicity of according to daily needs. On the display, values are displayed in real time for the programme activated, the current temperature, the time and the status of all the other functions set. It is possible to programme the desired temperature for every hour of the day (programming at 30 minute intervals is also possible), and for every day of the week. In addition, using a special function, the time-programmed thermostat of the Chiara series is able to automatically advance or delay switching on or off of systems in order to reach the ideal temperature exactly at the moment for which it was programmed. Adjustment of the thermal residual current device from 0.2°C to 2°C. Characteristics - Preset, adjustable and modifiable temperature levels: comfort, activity, reduction, anti-freeze fixed at +5°C - Change-over switching: winter for heating, summer for air conditioning - Limitation of the temperature values that can be set - Possibility to change at any time from comfort temperature to activity, reduction or anti-freeze - Display of the time and the ambient temperature - Temporary or permanent manual operation - Deletion from memory or modification of all the set information (day, time, temperature levels, etc.) - Availability of a totally free program, which can be programmed according to the strictest personal requirements - Possibility to suspend the program in progress for a set time cycle (maximum 999 hours) - Connection to a telephonic programming device for remote control - Possibility to activate the pump for 2 minutes every day of the year - Signalling of faults during operation of the installation (for example, boiler blocked) - Signalling that the battery for maintaining data in memory is low Preset temperature settings - T1 Comfort temperature 20°C adjustable - T2 Activity temperature 18°C adjustable - T3 Reduction temperature 16°C adjustable - T Anti-freeze temperature 5°C fixed Shown on the display - Days, hours, minutes - Ambient temperature detected - Temperature levels - Daily programming - Type of operation: manual, automatic, summer, winter Programming - 4 fixed programs - 1 free program - Programming at intervals of 30 minutes - Holidays program - Switching on or off with automatic management 5/48 2CSC600290D0201 | Mylos, Élos, Chiara Areas of application In residential applications, such as apartments and villas with independent heating, apartments with centralized heating, apartments or villas with independent air conditioning. In the services sector in environments equipped with air conditioning systems with fan coils and in environments equipped with centralized heating and zone valves. Wiring diagrams Example of connection to a motorized solenoid valve Open N Close C NO NC Power supply 230V~ 1 Technical specifications Power supply voltage 230 V - 50/60 Hz Maintenance of programs during power outages Output contact 72 hours minimum NO/COM/NC 8(2)A / 250 V~ Type of insulation Class II Protection class IP 30 (flush-mounted) Temperature adjustment range from + 5 °C to + 39 °C Temperatures setting resolution Temperature display resolution Thermal gradient 0.5 °C max 1°K/15 min. Differential operation T modifiable from 0,2 °C to 2 °C Updating of the temperature display Once every 60 seconds Operating temperature limits -5°C + 50°C 0.°C 5 2 3 N 4 L 5 Inputs for commands from telephonic programming device L N 230V~ Reference standards LVD EN60730-2-7, EN60730-2-9, EMC EN60730-2-7, EN60730-2-9 Example of connection to a boiler and telephonic programmer Boiler C NA NC Power supply 230V~ 1 2 3 N 4 L 5 Inputs for commands from telephonic programming device 6 7 L N 230V~ Telephonic programming device Contact for the thermostat’s control Mylos, Élos, Chiara | 2CSC600290D0201 5/49 Chiara - Technical details Safety and comfort devices Dimmer Loads that can be controlled with the dimmer Dimmer type Loads Fluorescent or halogen lamps 230V Dimmer code 2CSK1205CH 2CSK1207CH 5 2CSK1204CH Description Electronic dimmer YES with rotary control YES Electronic dimmer with button control YES Electronic dimmer with rotary control and two-way switch Description Electronic dimmer with rotary control for resistive loads Fluorescent lamps Toroidal transformers Electronic transformers Electromechanical transformers Drills Air agitators NO NO NO NO NO NO NO YES NO YES NO NO NO NO NO NO NO NO Code 2CSK1205CH 100-500W, 230V~ - 50/60Hz Wiring diagram The connection can be made between phase and neutral or between phase and phase, always in series with the load. Control with dimmer Components L N Location indicator light 230V~ 500VA ON/OFF command button with adjustment by rotation 1 2 3 Line voltage presence indicator light 2CSK1205CH Electronic dimmer with rotary control for resistive loads 100500W 230V~ 50/60Hz (visible in the dark). Control with a switch and adjustment with a dimmer L N 230V~ 500VA Operation The load can be controlled and adjusted by rotating the knob. The light intensity of the location LED is attenuated as the brightness of the controlled lamps increases. 1 2 3 2CSK1205CH Technical specifications Rated voltage 2CSC600290D0201 | Mylos, Élos, Chiara 110V - 50/60Hz Resistive load power 100 - 500W 50 – 250W Inductive load power 100 – 500VA 50 – 250VA Technology TRIAC TRIAC Operating temperature -5 °C ÷ +35 °C. Adjustable load Filament and halogen lamps Reference standards CEI 23-9 (EN 60669-1) 5/50 230V - 50/60Hz Description Electronic dimmer with pushbutton control for resistive and inductive Code 2CSK1207CH loads 60-500W, (60-500VA) 230V~ - 50/60Hz Wiring diagram The connection can be made between phase and neutral or between phase and phase, always in series with the load. Control and adjustment with a dimmer pushbutton Components Location indicator light L N 230V~ 500VA ON/OFF command button with adjustment by pressing Line voltage presence indicator light 1 2 3 5 2CSK1207CH Electronic dimmer with pushbutton control for resistive and inductive loads 60-500W 60-500VA 230V~ -50/60Hz (visible in the dark). Operation The load can be controlled and adjusted using a pushbutton. The light intensity of the location LED is attenuated as the brightness of the controlled lamps increases. The load can be turned on, adjusted and turned off using the pushbutton present on the dimmer or with normal non-luminous NO pushbuttons connected to the dimmer. – Storage of the adjustment set when the load was switched off (apart from network outages). – Switch-on and switch-off of the load is gradual. – Pressing the pushbutton quickly causes the load to be switched on or off. Adjustment is obtained by keeping it pressed. To reverse the direction of adjustment, interrupt and then resume pressing the pushbutton. – If the pushbutton is pressed approximately between 0.3 s and 1 s, the dimmer will light up the controlled lamps, automatically and gradually, to their maximum brightness. Control and adjustment with a dimmer pushbutton and NO button connected in parallel L N 230V~ 500VA 1 2 3 2CSK1207CH Technical specifications Rated voltage 230V - 50/60Hz 110V - 50/60Hz Resistive load power 60 - 500W 30 – 250W Inductive load power 60 – 500VA 30 – 250VA Technology TRIAC TRIAC Operating temperature -5 °C ÷ +35 °C. Adjustable load Filament and halogen lamps, ferromagnetic transformers for halogen lamps Reference standards CEI 23-9 (EN 60669-1) Mylos, Élos, Chiara | 2CSC600290D0201 5/51 Chiara - Technical details Safety and comfort devices Description Electronic dimmer with rotary control and with two-way switch for Code 2CSK1204CH resistive loads 100-500W, 230V~ - 50/60Hz Wiring diagram The connection can be made between phase and neutral or between phase and phase, always in series with the load. Control and adjustment with a dimmer Components L N Location indicator light 230V~ 500VA ON/OFF command button with adjustment by rotation 1 2 3 Line voltage presence indicator light 2CSK1204CH 5 Electronic dimmer with rotary control and two-way switch for resistive loads 100-500W 230V~ -50/60Hz (visible in the dark). Operation The load is controlled directly by means of a pressed two-way switch. Adjustment is performed by rotating the knob. The light intensity of the location LED is attenuated as the brightness of the controlled lamps increases. Once the desired lighting level has been set, pressing the knob will switch the light source off, while pressing it again will switch it back on at the set lighting level. Control with two-way switch and dimmer, adjustment with dimmer L N 230V~ 500VA 1 2 3 2CSK1204CH Control with two-way switch, intermediate switch and dimmer, adjustment with dimmer L N 230V~ 500VA 1 2 3 2CSK1204CH Technical specifications Rated voltage 230V - 50/60Hz 110V - 50/60Hz Resistive load power 100 - 500W 50 – 250W Inductive load power 100 – 500VA 50 – 250VA Technology TRIAC TRIAC Operating temperature -5 °C ÷ +35 °C. Adjustable load Filament and halogen lamps Reference standards CEI 23-9 (EN 60669-1) 5/52 2CSC600290D0201 | Mylos, Élos, Chiara Gas detectors Description Code Electronic natural gas detector with acoustic and indicator signal, relay 2CSK1210CH output, 1 NO/NC change-over contact 6A (AC1)/2A (AC15) - 250V~. Power supply 230V~ - 50Hz. Equipped with dedicated frame for installation on type 503 box Electronic LPG gas detector with acoustic and indicator signal, relay 2CSK1211CH Positioning of the detector The installation of the gas detector does not exonerate users from observance of all current laws and standards in the country of installation regarding the specifications, installation and use gas powered equipment, the ventilation of rooms and the release of combustion products. output, 1 NO/NC change-over contact 6A (AC1)/2A (AC15) - 250V~. Power supply 230V~ - 50Hz. 30 cm Equipped with dedicated frame for installation on type 503 box min. 1 m max. 4 m Natural gas detector Components 5 Frame Yellow LED 1 Malfunction of the device Pre-heating / Fault signalling Yellow LED 2 - Replacement of the probe module (after the first 5 years) replacement of the entire product (after another 5 years) consisting of the power supply module and the replaced probe module Green LED - Socket without network “Test/Reset” key: cancellation of the alarm memory, silencing the probe module or entire product replacement alarm, test to check the installation Red LED Alarm tripping / alarm memory completed LPG gas detector min. 1 m max. 4 m 30 cm - Install the natural gas detector at a maximum of 30 cm from the ceiling - Install the LPG detector at a maximum of 30 cm from the floor surface. - Install the detectors between 1 m and 4 m from the gas appliances. - Do not install the detectors outdoors or in places exposed to atmospheric agents - Do not install the detectors close to: sinks, air intakes, heating and air conditioning devices, windows and ventilation devices; in addition, the detectors must not be installed in closed spaces, such as behind a curtain or inside a cabinet. Holder for the label specifying the probe module replacement date The wiring accessories natural gas (CH4) or LPG gas detectors, flush-mounted with 3 modules (503 box embedded in the wall) contribute to guarantee the safety of civil environments where gas operated domestic appliances are installed, such as: boilers, cookers. The equipment consists of a fixed power supply module and removable sensor module, which must be replaced after 5 years of continuous use. This allows a saving on the purchase and installation costs, with a lower impact on the environment due to the extension of the life time of the power supply/relay module for a further 5 years. magnet valve Boiler Illustrative example: installation with 3 gas detectors (natural gas) that command the solenoid valve for shutting off the gassupply. Mylos, Élos, Chiara | 2CSC600290D0201 5/53 Chiara - Technical details Safety and comfort devices Extraction of the probe module (for example: to replace it) CAUTION: always deactivate the line voltage 230V~ 1. Remove the frame. 2. Delicately insert the flat blade of a small screwdriver and use it as a lever to uncouple the sensor module. 3. Rotate the sensor module upwards in order to uncouple it completely. Replacement probe modules: 2CSY1220MC: Natural Gas replacement probe module 2CSY1223MC: LPG Gas replacement probe module The diagrams (illustrative examples) show the position of the relay contacts at rest (no alarm). 5 rivel. fughe gas sostituire prodottoentro 06mese 2021 anno rivel. fughe gas 06 rivel. fughe gas 06 2016 mese anno sostituire modulo sonda 06 mese anno sonda sostituiremodulo Test / Reset Connection with solenoid valve normally closed 2016 mese anno sostituire modulo sonda 16 Wiring diagrams CAUTION: the power supply network must incorporate a device to guarantee omnipolar disconnection. The detector must be powered by a voltage of 230V~ 50Hz with continuity in order to guarantee maximum safety and correct signalling of replacement within the declared time limits. For the electrical connections, bring cables with a maximum cross-section of 2.5 mm² to the terminals of the detector. Test / Reset Test/ Reset NC magnet valve Characteristics - Devices equipped with a control circuit with microprocessor that performs self-diagnosis tasks to ensure the perfect efficiency of the sensor over time. - Sensor equipped with a special selective filter in order to avoid alarms in response to the presence of gas vapours that are not meant to be detected, such as steam from cooking, vapours from cleaning fluids etc. - Devices equipped with an operating time meter, in order to signal the necessary replacement of the sensor module after the firsts 5 years of use. - Luminous (red LED) and acoustic alarm signal. - TEST (to verify that the device is operating properly) and Reset system with a single pushbutton. - The gas detectors are equipped with an output relay that can command a valve to shut off the distribution of gas. Key to signals Luminous LED Acoustic BUZZER off off flashing on, fixed intermittent - Reference standards LVD CEI 216-8 - EMC EN 50270 Connection with solenoid valve normally open NO magnet valve (with manual reset) Technical specifications Power supply voltage 1 potential-free change-over contact Capacity of relay contacts (max) 6 (2) A 250 V ~ Protection class IP40 Type of insulation Class II Area of application Domestic - type A Semiconductor sensor Installed inside the probe module Operating temperature limits Operating humidity - 10 °C ÷ + 40 °C 90% UR (maximum) Types of gas detected Natural Gas - with model for natural gas Alarm tripping LPG - with model for LPG gas 10% LIE (Lower Explosiveness Limit) Acoustic alarm For both models 85 dB at 1 m Sensor warm-up time at switch-on Storage temperature limits 5/54 2CSC600290D0201 | Mylos, Élos, Chiara 230 V~ +/- 10% 50 Hz Solenoid valve command relay 1 minute - 15 °C ÷ + 50 °C Emergency lighting Description LED light for emergency lighting or steplight. Code 2CSK1303CH Charge reserve up to 3h and recharge time 12h. Power supply 230V~ - 50Hz. Equipped with dedicated frame for installation on type 503 box Components Yellow LED Green LED Frame Transparent diffuser High efficiency LED-lit emergency device for embedded installation. Dimensions of 3 modules. Suitable for installation of frames of the Chiara wiring accessories’ range. Instructions for installation and operation The light provides 6 distinct operating modes, that can be set by programming. Each time the diffuser is pressed, it increases the operating mode by one unit. After three cycles of displaying the mode, the device will automatically complete the programming procedure, store the mode that has been set and the GREEN and YELLOW LEDs will switch off. In modes 1-2-3 it is possible to adjust the lighting level (dimmering) by pressing the transparent diffuser. Functions The device is equipped with 2 signalling LEDs: 5 Green LED Meaning Flashing Apparatus connected to the electrical network being On quick-charged. Apparatus connected to the electrical network being Off recharged for maintenance Apparatus in emergency state. Yellow LED Meaning On The apparatus has faults Off (monthly test NOT passed) No malfunction Wiring diagram Mode Description Battery life Terminals 1 and 2 1 inhibition 1h Switch-on / switch-off / 2 not activated inhibition 2h adjustment Switch-on / switch-off / 3 not activated inhibition 3h adjustment Switch-on / switch-off / 4 not activated Inhibition activated 1h adjustment Connection for inhibition 5 Inhibition activated 2h switch Connection for inhibition 6 Inhibition activated 3h switch Connection for inhibition Modes 1, 2, 3 L N Modes 4, 5, 6 1 2 N NO push switch 1 2 230 V~ Switch Technical specifications Power supply voltage 230V~ ±10%, 50-60 Hz. Emergency light flow 50 lumen with 1h autonomy 35 lumen with 3h autonomy SE mode (not permanent) 5mA at 230V~ = 1.6W SA mode (permanent) 30mA at 230V~ = 7 W Ni-Mh batteries, AA 3.6V 1300mAh High Temperature 12 hours quick charge Consumption switch To access programming mode you need to connect the batteries using the appropriate connector: the yellow LED will light up and the green LED will flash a number of times equal to the mode set (for example, 2 flashes=mode 2). This sequence will be repeated 3 times. If you wish to change the operating mode, press the transparent diffuser: the yellow LED will switch off for a fraction of a second to indicate that the key has been pressed and the green LED will indicate the value of the new mode by the number of flashes. L 230 V~ Battery recharge time Battery life 1h, 2h and 3h Lamp 2 white high efficiency 1W LEDs Signalling 2 LEDs, GREEN and YELLOW Ambient Temperature 25°C Reference standards EN 60598-2-22 Mylos, Élos, Chiara | 2CSC600290D0201 5/55 Chiara - Technical details Safety and comfort devices Description Removable anti-blackout light, 230V~. Charge reserve 4.5 h and Code 2CSK1214CH recharge time 10-20h. To be combined with 230V~ plug sockets; particularly recommended for codes 2CSK1108CH and 2CSK1109CH. Components Green LED Red LED Pushbutton for manual activation 5 Battery Functions A light source is activated automatically whenever the line voltage is missing (blackout) thanks to rechargeable backup batteries. - Possibility to extract it from the socket and use it as a normal pocket torch with an on/off button on the front. - Long autonomy, 4.5 hours of continuous operation. - Small dimensions - protrusion from the Schuko profile (only 8 mm). On the front part there are two LEDs (one red and one green) that indicate the state of the lamp when it is powered: - Red LED on, recharging in progress. In the event of a blackout the lamp will remain off (battery saving condition, used in the case of prolonged absence). - Green LED on, recharging in progress. In the event of a blackout the lamp will light up and will switch off automatically when the network is restored. The pushbutton on the front part allows you to switch from one condition to another. 2P 10A plug, P11 type ON The anti-blackout light is an automatic removable, rechargeable electronic lamp that can be inserted in any Schuko socket or Italian P11 standard 10A bivalent socket. Socket outlets particularly recommended for holding the lamp are the sockets of the Chiara wiring accessories’ range 2CSK1108CH and 2CSK1109CH, that allow the body of the lamp to be embedded in the socket outlet, thus minimizing the external dimensions. The device was designed to light up automatically in the event of a blackout (no voltage warning), or to be used as a portable lighting device, useful in order to guarantee visibility and facilitate maintenance operations and/or searching for faults in unlit environments. Technical specifications Plug 2P 10A Center distance of the pins 19 mm Ø of the pins 4 mm Power supply 230V~50-60 Hz Recharge time 10-20 hours Useful battery life 4.5 hours Reference standards EN 60598-1, EN 60598-2 5/56 2CSC600290D0201 | Mylos, Élos, Chiara OFF Other devices Description IR motion detector with twilight sensor for control and adjustment of Code 2CSK1216CH the operation time of lighting devices. Relay output NO 5A (AC1)/2A (AC15) - 250V~. Instructions for installation - for installation inside - flush-mounted installation: 1.1-1.2 m from the walking surface Power supply 230V~ - 50/60Hz. 1,2 m Components Fresnel lens Adjustment of the twilight tripping threshold The apparatus cannot be installed in: - environments with sudden changes in temperature. - environments with high humidity. - environments with presence of gas, corrosive fluids, sea air or dust. 5 Schema di collegamento L N Adjustment of timing 2 1 Switch with infrared presence sensor in order to switch lights on through adjustable twilight sensor threshold and delay cycle. It operates the load automatically when persons or animals pass through the field of action of the sensor. N L Sensor volumetric cover A B B Examples of application A B A A B B A A Technical specifications m 8 6 4 2 0 2 4 Power supply 6 Pyroelectric reading sensor and Fresnel lens with volumetric cover. 230V AC (L-N terminals) Power relay output (terminals 1-2) Max load - resistive loads 10A / 250V AC - inductive loads 2A / 250V AC Tripping threshold 0-300 Lux A 1,2 Adjustable by means of a front m 0 B C 2 8 Time delay trimmer From approximately 5 s to approximately 5 min Front twilight sensor. Operating temperature Adjustable by means of a front trimmer -5 a +35 °C. Reference standards LV Directive; EMC Directive; EN 60730 Mylos, Élos, Chiara | 2CSC600290D0201 5/57 Chiara - Technical details Safety and comfort devices Description Universal badge switch with location light Relay output Code 2CSK1426CH with NO contact 10A (AC1). Power supply 230V~ 50/60Hz Vertical badge electronic switch, relay output 16 A 250 V~, power supply 230 V~ 50-60 Hz, modules. Supplied without ISO card (badge). The device is equipped with a courtesy LED for night-time location. Components Wiring diagram Badge slot Courtesy LED (on the front, under the slot) 5 230 V ~ NA Operation Load OFF 1 Load ON 2 L N Technical specifications Power supply 230 V~ ±10% 50-60 Hz Output relay with clean contact 10 A 250 V~ cos ø 1 230 V~ 50-60 Hz: 30 mA, with relay active -5 °C +45 °C Typical absorption Operating temperature Reference standards LV Directive; EMC Directive; Standard EN 60669-2-1 5/58 2CSC600290D0201 | Mylos, Élos, Chiara Chiara - Technical details Wall-mounted enclosures IP40 and IP55 wall-mounted enclosures Dedicated rectangular cable grommets Dedicated rectangular cable grommets IP55 watertight door IP40 enclosure 5 IP55 enclosure Area of application The IP40 wall-mounted enclosures, pursuant to Standard CEI 64-8, extend the area of application of the devices of the Chiara series to environments such as boiler rooms, warehouses, mechanical workshop, basements etc., where protection class IP40 is prescribed, defined by Standard EN 60529 (CEI 70-1). This is guaranteed through devices installed in the enclosures, if the installation is carried out according to the supported procedures, through the use of connections, cable grommets and pipe ducts. For devices with an open front (e.g. socket outlets) the protection class is less than IP40 but never less than IP20. IP55 watertight wall-mounted enclosures, on the other hand, allow the application of the equipment of the Chiara series in environments such as building sites, sports installations, marinas, industrial and agricultural establishments, gardens, camp sites etc. The protection class IP55, defined by the Standard EN 60529 (CEI 70-1), is guaranteed by devices installed in the enclosures, if the installation is carried out according to the supported procedures, through the use of the suitable accessories and with the cover closed. Dimensions of IP40 and IP55 enclosures H A P L H A L P IP40 enclosure no. modules H A L P 2CSK2140CH 1 38 80 65 55 2CSK2240CH 2 38 80 65 55 2CSK2340CH 3 38 80 104 55 2CSK2440CH 4 38 80 130 55 IP55 enclosure no. modules H A L P 2CSK2155CH 1 40,5 80 65 63 2CSK2255CH 2 40,5 80 65 63 2CSK2355CH 3 40,5 80 104 63 2CSK2455CH 4 40,5 80 130 63 Mylos, Élos, Chiara | 2CSC600290D0201 5/59 Chiara - Technical details Wall-mounted enclosures Because of the maximum depth dimension H, the IP40 and IP55 wall-mounted enclosures of the Chiara series cannot house the following contact blocks: Code 2CSK1204CH Description Electronic dimmer with rotary control and two-way switch Code 2CSK1307CH Description Automatic RCD 1P+N, C6 – 10 mA for resistive loads 100-500W 2CSK1308CH Automatic RCD 1P+N, C10 – 10 mA Electronic dimmer with rotary control for resistive loads 2CSK1309CH Automatic RCD 1P+N, C16 – 10 mA 100-500W 2CSK1328CH Automatic RCD 1P+N, C6 – 30 mA 2CSK1207CH Electronic dimmer with pushbutton control for resistive 2CSK1329CH Automatic RCD 1P+N, C10 – 30 mA and inductive loads 2CSK1330CH Automatic RCD 1P+N, C16 – 30 mA 2CSK1317CH Electro-mechanical bell, 12V, 5VA, sound intensity 80 dB 2CSK1324CH Interlocked socket with MCB (2P+E 16A 230V P17/11) 2CSK1318CH Electro-mechanical bell, 230V, 8VA, sound intensity 80 dB 2CSK1325CH Interlocked socket with MCB (2P+E 16A 230V) 2CSK1321CH Electro-mechanical buzzer, 12V, 5VA, sound intensity 70 dB 2CSK1326CH Interlocked socket with automatic RCD 10mA 2CSK1205CH 5 (2P+E 16A 230V P17/11) 2CSK1322CH Electro-mechanical buzzer, 230V, 8VA, sound intensity 70 dB 2CSK1304CH Automatic MCB 1P+N, C6 2CSK1012CH Single pole latching relay, 230V, 1 10A output contact 2CSK1305CH Automatic MCB 1P+N, C10 2CSK1014CH 4 sequence switch relay, 230V, 2 10A output contacts 2CSK1306CH Automatic MCB 1P+N, C16 The installation of similar devices in the form of a DIN rail in the distribution board is recommended where possible. 5/60 2CSC600290D0201 | Mylos, Élos, Chiara Chiara - Technical details Other installation solutions Support for DIN bar 1-2-3 modules Description Support for DIN bar for 1-2-3 modules, customisable Code 2CSK1608CH Components Instruction for installation 3 modules: snap assemble the two halves. 1 or 2 modules: using a cutter, cut along lines 1 or 2 respectively and assemble the two halves. DIN rail couplings Customisable adapter DIN rail couplings 5 Reference dimensions: 1 module version: 1,9 DIN modules 2 modules version: 3,4 DIN modules 3 modules version: 4,4 DIN modules Mylos, Élos, Chiara | 2CSC600290D0201 5/61 Chiara - Technical details Frames The frames of the Chiara series are made from technopolymer with natural/pastel colour shades or surface galvanic painting, and are characterised by their minimal protrusion from the wall, since they are not fitted with an under-plate. Reference standards CEI 23-9 (EN 60669-1). 5 Frame that adheres to all surfaces 2 ÷ 8 mm Customization Frames customized with a logo/text string can be supplied on request. They are produced by means of monochromatic pad printing on the areas highlighted below. 1 5 5/62 2 3 4 Position 2 Logo inside a rectangle 10 mm in height and 45mm in length Positions 1-3-4-5 Logo in square with 13 mm sides. 2CSC600290D0201 | Mylos, Élos, Chiara Customization is possible with standard colours (black, Pantone cool gray 3C, Pantone 5425 C) or with a colour specified by the customer. Minimum order batch: 36 pieces including various modularities. For quotes and delivery times contact an ABB sales executive. Chiara - Coding Order information Coding criteria of the devices 2 C S K 1 C Product family Fixed part of the code Product progressive number 0 Control devices 1 Socket outlets 2 Comfort devices 3 Protection devices and signalling devices 6 Components for installation, accessories and spare parts H Fixed part of the code 5 Example: single-pole switch 2 C S K 1 K 0 0 0 1 C H C H Coding criteria of the frames 2 C S Number of modules Fixed part of the code 2 2-module frame 3 3-module frame 4 4-module frame 7 7-module frame Colour code 01 02 03 04 11 12 13 14 15 16 17 Fixed part of the code 18 white sand stone volcano pastel yellow pastel orange pastel green pastel blue glossy chromium satin chromium glossy metal satin metal black 51 52 53 54 glossy bronze satin bronze glossy gold satin gold Example: technopolymer frame, 3 modules, sand colour 2 C S K 0 3 0 2 C H Packaging To enable automatic warehouse management using optical readers, the devices and frames of the Chiara wiring accessories’ range are packaged in boxes that bear the EAN bar code and that protect the contents adequately against dust and shocks. For a better explanations of the installation methods, a specific instruction sheet is supplied. Individual packages are available for only for the codes with the lowest turnover. Mylos, Élos, Chiara | 2CSC600290D0201 5/63 Chiara Overall dimensions 5 Chiara code Description No. Modules Depth mm 2CSK1001CH Single-pole switch, 16A - 250V~ 1 30 2CSK1002CH Double-pole switch, 16A - 250V~ 1 30 2CSK1003CH Single-pole two-way switch, 16A - 250V~ 1 30 2CSK1004CH Single-pole switch, 16A - 250V~, 2 modules 2 30 2CSK1005CH Single-pole push switch NO, 16A 1 30 2CSK1006CH Double-pole switch, 16A - 250V~, with key control 1 25 2CSK1006CHU Double-pole switch, 16A - 250V~, with universal key control 1 25 2CSK1007CH Single-pole two-way switch, 16A - 250V~, 2 modules 2 30 2CSK1008CH Intermediate switch, 16A - 250V~, 2 modules 2 30 2CSK1009CH Double-pole push switch, NO, 16A - 250V~, with key control 1 25 2CSK1009CHU Double-pole push switch, NO, 16A - 250V~, 1 25 1 module 45 22 2 modules with universal key control 45 2CSK1010CH Intermediate switch, 16A - 250V~ 1 30 2CSK1011CH Change-over switch, 10A - 250V~, 3 positions 1 31 2CSK1012CH Single pole latching relay, 230V 1 31 2CSK1014CH 4 sequence switch relay, 230V, 2 10A output contacts 1 31 2CSK1016CH Single-pole push switch NC, 16A 1 30 2CSK1017CH Double single-pole push switch, NO+NO, 16A - 250V~ 1 30 Double single-pole push switch, NO+NO, 16A - 250V~, 1 30 2CSK1018CH 44 3 modules with interlock 2CSK1022CH Single-pole push switch 1 NO and 1 NC, 16A, with ON 1 30 2CSK1023CH Single-pole push switch 1 NO and 1 NC, 16A, 1 30 45 with OFF symbol 2CSK1020CH Single-pole push switch NC with cord pull, 16A 1 30 2CSK1021CH Single-pole push switch NC with cord pull, 16A 1 30 2CSK1028CH Single-pole push switch NO, 16A, with BELL 1 30 2CSK1029CH Single-pole push switch NO, 16A, with KEY 1 30 2CSK1030CH Single-pole push switch NO, 16A, with STAIR LIGHT 1 30 2CSK1024CH Single-pole push switch NO, 16A, with red diffuser 1 30 2CSK1025CH Single-pole push switch NO, 16A, with green diffuser 1 30 2CSK1026CH Single-pole push switch NO, 16A, with orange diffuser 1 30 2CSK1027CH Single-pole push switch NO, 16A, with white diffuser 1 30 2CSK1031CH Single-pole pushbutton NO, 16A, with backlit label 2 30 3 30 holder plate push switch 2CSK1032CH Single-pole push switch NO, 16A, with backlit label holder plate, 3 modules 2CSK1101CH 2P+E socket outlet, 10A - 250V~, P11 type 1 22 2CSK1102CH 2P+E socket outlet, 16A - 250V~, P17 type 1 22 2CSK1103CH 2P+E socket outlet, 10/16A - 250V~, P17/P11 type 1 22 2CSK1104CH 2P+E socket outlets, 10/16A, red 1 22 2CSK1105CH 2P+E socket outlets, 10/16A, green 1 22 2CSK1106CH 2P+E socket outlets, 10/16A, orange 1 22 2CSK1108CH 2P+E socket outlet, 16A - 250V~, P30 type 2 31 2CSK1114CH 2P+E socket outlets, 16A - 250V~, P30 type, red 2 31 2CSK1115CH 2P+E socket outlets, 16A - 250V~, P30 type, green 2 31 2CSK1116CH 2P+E socket outlets, 16A - 250V~, P30 type, orange 2 31 2CSK1109CH 2P+E socket outlet, 16A - 250V~, P30/17 type 2 35 2CSK1110CH 2P+E socket outlets, 16A - 250V~, P30/17 type, red 2 35 2CSK1111CH 2P+E socket outlets, 16A - 250V~, P30/17 type, green 2 35 2CSK1112CH 2P+E socket outlets, 16A - 250V~, P30/17 type, orange 2 35 2CSK1113CH 2P shaver socket with insulating transformer 3 37,5 5/64 2CSC600290D0201 | Mylos, Élos, Chiara 66 Chiara code Description No. Modules Depth mm 2CSK1324CH 2P+E socket outlet, 16A - 250V~, interlocked with MCB, 2 37,5 2CSK1325CH P17/11 2P+E socket outlet, 16A - 250V~, interlocked with MCB, 3 37,5 2CSK1326CH P30 2P+E socket outlet, 16A - 250V~, with RCD 10mA, 3 37,5 P17/11 2CSK1117CH TV coaxial socket, direct, male IEC connector ø 9.5 mm, 1 21 2CSK1118CH insulated type TV/SAT coaxial socket, direct, male IEC connector 1 21 2CSK1132CH ø 9.5 mm, with feedthrough of direct current TV/SAT coaxial socket, feedthrough, male IEC connector 1 21 2CSK1136CH ø 9.5 mm, attenuation 7dB TV/SAT coaxial socket, feedthrough, male IEC connector 1 21 2CSK1137CH ø 9.5 mm, attenuation 10dB TV/SAT coaxial socket, feedthrough, male IEC connector 1 21 2CSK1138CH ø 9.5 mm, attenuation 14dB TV/SAT coaxial socket, feedthrough, male IEC connector 1 21 2CSK1119CH ø 9.5 mm, attenuation 18dB TV/SAT coaxial socket, direct, female F connector, 1 21 2CSK1133CH with feedthrough of direct current Double demixed TV/SAT coaxial socket, direct, male IEC 1 21 2CSK1120CH connector ø 9.5 mm and female F connector Double demixed TV/SAT coaxial socket, feedthrough, 1 21 1 21 1 21 1 21 attenuation 18dB RJ11 telephone connector 1 21 2CSK1122CH RJ12 telephone connector 1 21 2CSK1124CH RJ45 connector, Cat. 5e, UTP (unshielded) 1 21 2CSK1125CH RJ45 connector, Cat. 5e, FTP (shielded) 1 21 2CSK1127CH RJ45 connector, Cat. 6, UTP (unshielded) 1 21 2CSK1128CH RJ45 connector, Cat. 6, FTP (shielded) 1 21 2CSK1160CH Flush-mounted USB charger 500-650mA 1 35 2CSK1210CH Electronic natural gas detector 3 39 2CSK1211CH Electronic LPG gas detector with acoustic and 3 39 5 male IEC connector ø 9.5 mm and female F connector, 2CSK1130CH attenuation 7dB Double demixed TV/SAT coaxial socket, feedthrough, male IEC connector ø 9.5 mm and female F connector, 2CSK1131CH attenuation 10dB Double demixed TV/SAT coaxial socket, feedthrough, male IEC connector ø 9.5 mm and female F connector, 2CSK1139CH attenuation 14dB Double demixed TV/SAT coaxial socket, feedthrough, male IEC connector ø 9.5 mm and female F connector, 2CSK1121CH indicator signal 2CSK1301CH Fuse holder, for fuses Ø5x20 / Ø6.3x32 mm, max. 16A 1 26 2CSK1303CH LED light for emergency lighting or steplight 3 50 2CSK1304CH Automatic MCB, 1P+N, C6, breaking capacity 1.5kA 1 36 2CSK1305CH Automatic MCB, 1P+N, C10, breaking capacity 3kA 1 36 2CSK1306CH Automatic MCB, 1P+N, C16, breaking capacity 3kA 1 36 2CSK1307CH Automatic RCD, 1P+N, C6 - 10 mA, 2 36 2 36 breaking capacity 1.5kA 2CSK1308CH Automatic RCD, 1P+N, C10 - 10 mA, breaking capacity 3kA Mylos, Élos, Chiara | 2CSC600290D0201 5/65 Chiara Overall dimensions Chiara code Description No. Modules Depth mm 2CSK1309CH Automatic RCD, 1P+N, C16 - 10 mA, 2 36 breaking capacity 3kA 2CSK1315CH Overvoltage limiter, 75J, 230V~ 1 26 2CSK1328CH Automatic RCD, 1P+N, C6 - 30 mA, 2 36 2CSK1329CH Automatic RCD, 1P+N, C10 - 30 mA, 2 36 2 36 breaking capacity 1.5kA breaking capacity 3kA 2CSK1330CH Automatic RCD, 1P+N, C16 - 30 mA, breaking capacity 3kA 5 2CSK1310CH Warning light, ORANGE colour 1 20 2CSK1311CH Warning light, WHITE colour 1 20 2CSK1312CH Warning light, RED colour 1 20 2CSK1313CH Warning light, GREEN colour 1 20 2CSK1317CH Electro-mechanical bell, 12V 1 37 2CSK1318CH Electro-mechanical bell, 230V, 1 37 2CSK1321CH Electro-mechanical buzzer, 12V 1 37 2CSK1322CH Electro-mechanical buzzer, 230V 1 37 2CSK1201CH Summer/winter electronic time-programmed thermostat 3 38 2CSK1202CH Summer/winter electronic thermostat 2 29,5 2CSK1205CH Electronic dimmer with rotary control for resistive loads 1 39 1 39 1 39 100-500W 2CSK1204CH Electronic dimmer with rotary control and two-way switch for resistive loads 100-500W 2CSK1207CH Electronic dimmer with pushbutton control for resistive and inductive loads 60-500W 2CSK1214CH Removable anti-blackout light, 230V see drawing 2CSK1216CH IR motion detector with twilight sensor for control and 1 32 2 32 adjustment of the operation time of lighting devices 2CSK1426CH 5/66 Universal badge switch with location light 2CSC600290D0201 | Mylos, Élos, Chiara Frames 2 modules 3 modules 4 modules 92 92 97 92 119 141 7 modules 5 92 209 Self-supporting frames 2 modules 3 modules 4 modules 79 79 79 97 119 Screw distance: 60 mm 141 Screw distance: 83.5 mm Screwr distance: 108 mm 3 modules 4 modules Supports 2 modules 79 79 93,5 115 Screw distance of the box: 60 mm Screw distance of the box: 83.5 mm 79 137,5 Screw distance of the box: 108 mm 7 moduli 79 205 Screw distance of the box: 100 mm All measurements are in millimetres. Mylos, Élos, Chiara | 2CSC600290D0201 5/67 Chiara Overall dimensions Safety and comfort devices Anti-blackout light 43 26 44 5 IP40 wall-mounted enclosures 2 modules 3 modules 4 modules 80 80 80 65 55 130 104 IP55 wall-mounted enclosures 2 modules 3 modules 4 modules 80 65 80 80 130 104 63 IP55 flush-mounted escutcheon plate 91 96 All measurements are in millimetres. 5/68 2CSC600290D0201 | Mylos, Élos, Chiara 118 35