SKN 400, SKR 400 VRSM V VRRM V 1800 2000 2400 2700 3000 3600 1800 2000 2400 2700 3000 3600 IFRMS = 700 A (maximum value for continuous operation) IFAV = 400 A (sin. 180; Tc = 100 ºC) SKN 400/18 SKN 400/20 SKN 400/24 SKN 400/27 SKN 400/30 SKN 400/36 SKR 400/18 SKR 400/20 SKR 400/24 SKR 400/27 SKR 400/30 SKR 400/36 Stud Diode Rectifier Diode SKN 400 SKR 400 Features • • • • • • • • • High voltage rectifier diode, especially for traction applications Cooling via heatsinks Non-controllable and halfcontrollable rectifiers Free-wheeling diodes Recommended snubber network: RC: 1,0 µF, 20 Ω (PR = 5W), Rp: 25 KΩ (PR = 20 W) SKN 1 Condition IFAV ID sin. 180 ; TC = 85 (100) ºC K 0,55; Ta = 45 ºC; B2 / B6 K 0,55F; Ta = 35 ºC; B2 / B6 IFSM Tvj = 25º C ; 10 ms Tvj = 160º C ; 10 ms Tvj = 25º C ; 8,3...10 ms Tvj = 160º C ; 8,3...10 ms 2 Reverse voltages up to 3600 V Hermetic metal cases with glass insulator Threaded stud M24 x 1,5 mm. SKN: anode to stud SKR: cathode to stud Typical Applications * • Symbol it VF V(TO) rT IRD Qrr Tvj = 25º C, IF = 1200 A Tvj = 160º C Tvj = 160º C Tvj = 160º C ; VR = VRRM Tvj = 160°C, -diF/dt = 10 A/µs Rth(j-c) Rth(c-s) Tvj Tstg Visol Ms a m to heatsink (SI units) to heatsink (US units) approx. Case Values Units 445 (400) 310 / 450 700 / 1000 A A A 9000 7500 400000 280000 A A 2 As 2 As max. 1,45 max. 0,9 max. 0,5 max. 60 typ. 400 V V mΩ mA µC 0,11 0,01 -40...+160 -55...+160 K/W K/W 60 531 V~ Nm lb.in. 5 * 9,81 500 m/s g °C °C 2 E 17 SKR 2015-12-07 RP © by SEMIKRON SKN 400, SKR 400 2 Fig. 1L Power dissipation vs. forward current Fig. 1R Power dissipation vs. ambient temperature Fig. 2 Forward current vs. case temperature Fig. 4 Transient thermal impedance vs. time Fig. 5 Forward characteristics Fig. 6 Surge overload current vs. time 2015-12-07 RP © by SEMIKRON SKN 400, SKR 400 Dimensions in mm Case E17 (IEC 60191: A 22 B) * The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our personal. 3 2015-12-07 RP © by SEMIKRON