384

EVEREADY BATTERY CO.
Internet: www.energizer.com
1-800-383-7323
/ USA/ USA
1-800-383-7323
1-800-383-7323
/ CANADA
1-800-383-7323
/ CANADA
+ 44 (0) 208 920 2306 / EUROPE
ENERGIZER NO. 384
Industry Standard Dimensions in mm (inches)
Chemical System:
Silver Oxide (Zn/Ag20)
Designation:
Battery Voltage:
Average Weight:
Volume:
Average Capacity:
ANSI / NEDA-1134SO, IEC-SR41
1.55 Volts
0.57 grams (0.020 oz.)
0.18 cubic centimeters (0.011 cubic inch)
41 mAh to 1.3 volts
(Rated at 15k ohms continuous at 21ºC)
TYPICAL DISCHARGE CURVE
Simulated Test @ 21ºC (70ºF)
Closed Circuit Voltage
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
DESIGNED FOR USE ON CONTINUOUS LOW DRAIN
0
50
100
150
200
250
300
350
400
450
Service, Hours
Simulated Application Test
Estimated Average Service at 21ºC (70ºF)
Cutoff Voltage
Schedule:
Typical Drains
at 1.55V
(milliamperes)
Load
(ohms)
1.3V
24 hours/day
0.103
15,000
400 Hours
INTERNAL RESISTANCE: Closed circuit voltage no less than 1.00 volts on a load of 100
ohms at 21ºC (70ºF) for 0.1 to 2.0 seconds.
Typical closed circuit voltage during discharge on a load of 2,000 ohms
for 0.0078 seconds.
Depth of Discharge as Percent of Rated Capacity
Temperature
21ºC (70ºF)
-10ºC (14ºF)
0%
1.57V
1.44V
40%
1.55V
1.44V
80%
1.54V
1.43V
Important Notice
This data sheet contains information specific to batteries manufactured at the time of its publication.
Contents herein do not constitute a warranty.
Copyright © Eveready Battery Co. Inc. - All Rights Reserved
Form No. EBC - 4333C
Page 1 of 1