EVEREADY BATTERY CO. Internet: www.energizer.com 1-800-383-7323 / USA/ USA 1-800-383-7323 1-800-383-7323 / CANADA 1-800-383-7323 / CANADA + 44 (0) 208 920 2306 / EUROPE ENERGIZER NO. A76 Industry Standard Dimensions in mm (inches) Chemical System: Manganese Dioxide (Mn02) Designation: Battery Voltage: Average Weight: Volume: Average Capacity: ANSI / NEDA-1166A, IEC - LR48 1.5 Volts 2.3 grams (0.08 oz.) 0.50 cubic centimeters (0.03 cubic inch) 150 mAh to 0.9 volts (Rated at 7.5k ohms continuous at 21ºC) TYPICAL DISCHARGE CURVE Simulated Test @ 21ºC (70ºF) Closed Circuit Voltage 1.6 1.5 1.4 1.3 1.2 1.1 1.0 0.9 0.8 DESIGNED FOR ELECTRONIC APPLICATIONS WHICH MAY REQUIRE HIGH RATE PULSES 0 150 300 450 600 750 900 Service, Hours Simulated Application Test Estimated Average Service at 21ºC (70ºF) Schedule: Typical Drains at 1.25V (microamperes) Load (ohms) 0.9V 24 hours/day 0.17 7,500 900 Hours Cutoff Voltage BULGE DATA: This battery will bulge as it is discharged but will not exceed the maximum height shown on the battery drawing. INTERNAL RESISTANCE: Typical closed circuit voltage during discharge on a load of 100 ohms for 0.10 to 2.0 seconds. Depth of Discharge as Percent of Rated Capacity Temperature 0% 40% 80% 21ºC (70ºF) 1.55V 1.29V 1.10V Important Notice This data sheet contains information specific to batteries manufactured at the time of its publication. Contents herein do not constitute a warranty. Copyright © Eveready Battery Co. Inc. - All Rights Reserved Form No. EBC - 4407D Page 1 of 1