Datenblatt

For more information, please visit the product page.
date
09/24/2013
page
1 of 4
MODEL: CMA-4544PF-W │ DESCRIPTION: ELECTRET CONDENSER MICROPHONE
SPECIFICATIONS
parameter
conditions/description
directivity
omnidirectional
sensitivity (S)
f = 1 kHz, 1 Pa, 0 dB = 1 V/1 Pa
min
typ
max
units
-46
-44
-42
dB
3
10
Vdc
operating voltage
output impedance (Zout)
f = 1 kHz, 1 Pa
2.2
KΩ
sensitivity reduction (∆S-Vs)
f = 1 kHz, 1 Pa, Vs = 3.0 to 2.0 Vdc
-3
dB
frequency (f)
20
current consumption (IDSS)
Vs = 3.0 Vdc, RL = 2.2 KΩ
signal to noise ratio (S/N)
f = 1 kHz, 1 Pa, A-weighted
Hz
0.5
mA
60
operating temperature
storage temperature
dimension
20,000
dBA
-20
70
°C
-20
70
°C
0.8
g
ø9.7 x 4.5 mm
weight
material
Al
terminal
pin type (hand soldering only)
RoHS
yes
Note:
We use the “Pascal (Pa)” indication of sensitivity as per the recomendation of I.E.C. (International Electrotechnical Commission). The sensitivity of “Pa” will increase 20dB
compared to the “ubar” indication. Example: -60dB (0dB = 1V/ubar) = -40dB (1V/Pa)
MECHANICAL DRAWING
MEASUREMENT CIRCUIT
unit: mm
RL = 2.2 KΩ
ŇņŕġŊŮűŦťŢůŤŦ
ŤŰůŷŦųŵŦų
ŕŦųŮįIJ
ńľIJŶŇ
œō
ņįńįŎį
ŶůŪŵ
ŔũŪŦŭťġńŢŴŦ
Schematic Diagram
cui.com
ŐŶŵűŶŵ
ĬŗŴ
ŕŦųŮįij
ĮňųŰŶůť
For more information, please visit the product page.
CUI Inc │ MODEL: CMA-4544PF-W │ DESCRIPTION: ELECTRET CONDENSER MICROPHONE
date 09/24/2013 │ page 2 of 4
FREQUENCY RESPONSE CURVE
ijı
IJı
ĩťŃĪ ı
ĮIJı
Įijı
ĮĴı
ijı
Ķı
IJıı
ijıı
Ķıı
IJŌ ijŌ
ĶŌ
IJıŌ
ijıŌ
ĩʼnŻĪ
1.000V/PA
MECHANICAL CHARACTERISTICS
item
test condition
evaluation standard
soldering heat resistance
Soldering iron of +270 ±5°C should be placed on the
terminal for 2 ±0.5 seconds.
No interference in operation.
terminal mechanical strength
Apply to the terminal 4.9 N (0.5 kg) for 30 seconds
No damage or cutting off.
vibration test
The part should be measured after a vibration amplitude of
1.5 mm with 10~55 Hz band of vibration frequency to each
of the 3 perpendicular directions for 2 hours.
drop test
The part without packaging is subjected to 3 drops on each
axis from the height of 1 m onto a 20 mm thick wooden
board.
After any tests, the sensitivity should be
within ±3 dB of the initial sensitivity.
ENVIRONMENT TEST
item
test condition
high temperature test
After being placed in a chamber at +70°C for 72 hours.
evaluation standard
low temperature test
After being placed in a chamber at -20°C for 72 hours.
thermal shock
After being placed in a chamber at +40°C and 90 ±5% RH
for 240 hours.
The part will be subjected to 10 cycles. One cycle will
consist of:
After any tests and 6 hours of
conditioning at +25°C, the
sensitivity should be within ±3 dB of the
initial sensitivity.
temperature cycle test
TEST CONDITIONS
standard test conditions
a) Temperature: +5 ~ +35°C
b) Humidity: 45 ~ 85%
c) Pressure: 860 ~ 1060 mbar
judgement test conditions
a) Temperature: +25 ±2°C
b) Humidity: 60 ~ 70%
c) Pressure: 860 ~ 1060 mbar
cui.com
For more information, please visit the product page.
CUI Inc │ MODEL: CMA-4544PF-W │ DESCRIPTION: ELECTRET CONDENSER MICROPHONE
PACKAGING
cui.com
date 09/24/2013 │ page 3 of 4
For more information, please visit the product page.
CUI Inc │ MODEL: CMA-4544PF-W │ DESCRIPTION: ELECTRET CONDENSER MICROPHONE
date 09/24/2013 │ page 4 of 4
REVISION HISTORY
rev.
description
date
1.0
initial release
06/01/2008
1.01
new template applied, updated drawing
09/24/2013
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.