MUX8507 (5/14)

Standard Products
Datasheet
MUX8507 64-Channel Analog Multiplexer Module
Radiation Tolerant
www.aeroflex.com/mux
May 5, 2014
FEATURES












64-Channels provided by six 16-channel multiplexers- 32 Kelvin measurement configured channels
Radiation performance
- Total dose:
300 krads(Si), Dose rate = 50 - 300 rads(Si)/s
- SEU:
Immune up to 120 MeV-cm2/mg
- SEL:
Immune by process design
Full military temperature range
Low power consumption < 90mW
Two address buses (A0-3 & B0-3) and four enable lines afford flexible organization.
Fast access time 1500ns typical
Break-Before-Make switching
Same Form / Fit / Function as ACT8500 minus channel input transorbs
High analog input impedance (power on or off) ?
Designed for aerospace and high reliability space applications
Packaging – Hermetic ceramic
- 96 leads, 1.32"Sq x 0.20"Ht quad flat pack
- Typical Weight 15 grams
Aeroflex Plainview’s Radiation Hardness Assurance Plan is DLA Certified to MIL-PRF-38534, Appendix G.
GENERAL DESCRIPTION
Aeroflex’s MUX8507 is a radiation tolerant, 64 channel multiplexer MCM (multi-chip module).
The MUX8507 has been specifically designed to meet exposure to radiation environments. It is available in
a 96 lead High Temperature Co-Fired Ceramic (HTCC) Quad Flatpack (CQFP). It is guaranteed operational
from -55°C to +125°C. Available screened in accordance with MIL-PRF-38534, the MUX8507 is ideal for
demanding military and space applications.
ORGANIZATION AND APPLICATION
The MUX8507 consists of six 16 channel multiplexers arranged as shown in the Block Diagram. The
MUX8507 design is inherently radiation tolerant.
A SECTION
Thirty-two (32) Kelvin measurement channels addressable by bus A0~A3, in two 16 channel blocks, each
block enabled separately. Each block connects the addressed channel to two outputs, "Output" and
"Current". This technique enables selecting and reading a remote resistive sensor without the multiplexer
resistance being part of the measurement. For grounded sensors, this is done by passing current to the sensor
by means of the "Current" pin and reading the resultant voltage (proportional to the sensor resistance) at the
"Output" pin.
B SECTION
Thirty-two (32) channels addressable by bus B0~B3, in two 16 channel blocks, each block enabled
separately. Each block connects the addressed channel to one output. By paralleling the channel inputs and
enables, this section can be converted to act like one of the 16 channel blocks of the A section.
SCD8507 Rev C
SCD8507 Rev C 5/5/14
2
Aeroflex Plainview
GND
VREF
-VEE
+VEE
A0
A1
A2
A3
EN 32-47
CH 47
•
•
•
CH 32
B0
B1
B2
B3
EN 0-15
CH 15
•
•
•
CH 0
16
16
16
EN 16-31
CH 31
CH 63
EN 48-63
CURRENT 32-47
OUTPUT 32-47
•
•
•
CH 48
SECTION A: Kelvin Measurement Configured
OUTPUT 0-15
•
•
•
CH 16
16
16
16
MUX8507 64 – CHANNEL ANALOG MUX BLOCK DIAGRAM
MUX 5
MUX 3
MUX 1
SECTION B
MUX 6
MUX 4
MUX 2
CURRENT 48-63
OUTPUT 48-63
OUTPUT 16-31
ABSOLUTE MAXIMUM RATINGS 1/
Parameter
Range
Units
Case Operating Temperature Range
-55 to +125
C
Storage Temperature Range
-65 to +150
C
+16.5
-16.5
+16.5
V
V
V
< VREF +4
> GND -4
V
V
±35
V
Supply Voltage
+VEE (Pin 44)
-VEE (Pin 46)
VREF (Pin 48)
Digital Input Overvoltage
VEN (Pins 5, 6, 91, 92), VA (Pins 1, 3, 93, 95), VB (Pins 2, 4, 94, 96)
Analog Input Over Voltage
VIN
Notes:
1/ All measurements are made with respect to ground.
NOTICE: Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress rating only;
functional operation beyond the "Operation Conditions" is not recommended and extended exposure beyond the "Operation Conditions" may affect
device reliability.
RECOMMENDED OPERATING CONDITIONS 1/
Symbol
Parameter
Typical
Units
+VEE
Positive Power Supply Voltage
+12.0 to +15.0 dc ± 5%
V
-VEE
Negative Power Supply Voltage
-12.0 to -15.0 dc ± 5%
V
VREF
Reference Voltage
+5.0
V
VAL
Logic Low Level
+0.8
V
VAH
Logic High Level
+4.0
V
Notes:
1/ Power Supply turn-on sequence shall be as follows: +VEE, -VEE, followed by VREF.
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/
(Tc = -55°C to +125°C, +VEE = +15.75V, -VEE = -15.75V, VREF = +5.0V, Unless otherwise specified)
Parameter
Supply Current
Symbol
+IEE
-IEE
+ISBY
-ISBY
Address Input Current
Enable Input Current
SCD8507 Rev C 5/5/14
Conditions
VEN(0-63) = VA(0-3)A = VA(0-3)B = 0
VEN(0-63) = 4V, VA(0-3)A = VA(0-3)B = 0 6/
Min
Max
Units
0
3
mA
-3
0
mA
0
3
mA
-3
0
mA
IAL(0-3)A
VA = 0V 8/
-4
4
A
IAH(0-3)A
VA = 5V 8/
-4
4
A
IAL(0-3)B
VB = 0V 8/
-2
2
A
IAH(0-3)B
VB = 5V 8/
-2
2
A
IENL(0-15)
VEN(0-15) = 0V 8/
-1
1
A
IENH(0-15)
VEN(0-15) = 5V 8/
-1
1
A
IENL(16-31)
VEN(16-31) = 0V 8/
-1
1
A
IENH(16-31)
VEN(16-31) = 5V 8/
-1
1
A
IENL(32-47)
VEN(32-47) = 0V 8/
-2
2
A
IENH(32-47)
VEN(32-47) = 5V 8/
-2
2
A
IENL(48-63)
VEN(48-63) = 0V 8/
-2
2
A
IENH(48-63)
VEN(48-63) = 5V 8/
-2
2
A
3
Aeroflex Plainview
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/ (continued)
(Tc = -55°C to +125°C, +VEE = +15.75V, -VEE = -15.75V, VREF = +5.0V, Unless otherwise specified)
Parameter
Positive Input
Leakage Current
CH0-CH31
Positive Input
Leakage Current
CH32-CH63
Negative Input
Leakage Current
CH0-CH31
Negative Input
Leakage Current
CH32-CH63
Symbol
Conditions
Min
Max
Units
+ISOFFOUTPUT(0-31)
VIN = +10V, VEN = 4V, output and all unused
MUX inputs under test = -10V 2/, 3/, 8/
+25°C
-10
+10
nA
-
-100
+100
nA
+ISOFFOUTPUT(32-63)
+25°C
-20
+20
nA
+ISOFFCURRENT(32-63)
VIN = +10V, VEN = 4V, output and all unused
MUX inputs under test = -10V 2/, 3/, 8/
-
-200
+200
nA
-ISOFFOUTPUT(0-31)
VIN = -10V, VEN = 4V, output and all unused
MUX inputs under test = +10V 2/, 3/, 8/
+25°C
-10
+10
nA
-
-100
+100
nA
-ISOFFOUTPUT(32-63)
VIN = -10V, VEN = 4V, output and all unused
MUX inputs under test = +10V 2/, 3/, 8/
+25°C
-20
+20
nA
-
-200
+200
nA
-100
+100
nA
-100
+100
nA
-100
+100
nA
-100
+100
nA
-ISOFFCURRENT(32-63)
Output Leakage Current
OUTPUTS
(pins 25, 26, 68 & 70)
CURRENTS
(pins 67 & 69)
Output Leakage Current
OUTPUTS
(pins 25, 26, 68 & 70)
+IDOFFOUTPUT
+IDOFFCURRENT
VOUT = +10V, VEN = 4V, output and all unused MUX
inputs under test = -10V 3/, 4/, 8/
-IDOFFOUTPUT
VOUT = -10V, VEN = 4V, output and all unused MUX inputs
under test = +10V 3/, 4/, 8/
CURRENTS
(pins 67 & 69)
-IDOFFCURRENT
Switch ON Resistance
OUTPUTS
(pins 25, 26, 68 & 70)
RDS(ON)(0-63)A
VIN = +15.75V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/
500
3000

RDS(ON)(0-63)B
VIN = +5V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/
500
3000

RDS(ON)(0-63)C
VIN = -5V, VEN = 0.8V, IOUT = +1mA
2/, 3/, 5/
500
3000

RDS(ON)(0-63)A
VIN = +15.75V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/
500
3000

RDS(ON)(0-63)B
VIN = +5V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/
500
3000

RDS(ON)(0-63)C
VIN = -5V, VEN = 0.8V, IOUT = +1mA
2/, 3/, 5/
500
3000

RDS(ON)(0-63)A
VIN = +11.4V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/, 7/
500
3200

RDS(ON)(0-63)B
VIN = +5V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/, 7/
500
3000

RDS(ON)(0-63)C
VIN = -5V, VEN = 0.8V, IOUT = +1mA
2/, 3/, 5/, 7/
500
3000

RDS(ON)(32-63)A
VIN = +11.4V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/, 7/
500
3200

RDS(ON)(32-63)B
VIN = +5V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/, 7/
500
3000

RDS(ON)(32-63)C
VIN = -5V, VEN = 0.8V, IOUT = +1mA
2/, 3/, 5/, 7/
500
3000

Switch ON Resistance
CURRENTS
(pins 67 & 69)
Switch ON Resistance
OUTPUTS
(pins 25, 26, 68 & 70)
Switch ON Resistance
CURRENTS
(pins 67 & 69)
Notes:
1/ Measure inputs sequentially. Ground all unused inputs of the device under test. VA is the applied input voltage to the address lines A(0-3). VB is the
applied input voltage to the address lines B(0-3).
2/ VIN is the applied input voltage to the input channels CH0-CH63.
3/ VEN is the applied input voltage to the enable lines EN (0-15), EN (16-31), EN (32-47) and EN (48-63).
4/ VOUT is the applied input voltage to the output lines OUTPUT(0-15), OUTPUT(16-31), OUTPUT(32-47), OUTPUT(48-63), CURRENT(32-47) and
CURRENT(48-63).
5/ Negative current is the current flowing out of each of the MUX pins. Positive current is the current flowing into each MUX pin.
6/ Not tested, guaranteed to the specified limits.
7/ +VEE = +11.4 Vdc, -VEE = -11.4 Vdc and VREF = 5.0 V
8/ These parameters for Tc = -55°C are guaranteed by design, characterization, or correlation to other test parameters but not production tested.
SCD8507 Rev C 5/5/14
4
Aeroflex Plainview
SWITCHING CHARACTERISTICS
(Tc = -55°C to +125°C, +VEE = +15.75V, -VEE = -15.75V, VREF = +5.0V, Unless otherwise specified)
Parameter
Switching Test MUX
Symbol
Conditions
tAHL
RL = 10K, CL = 50pF
tALH
RL = 10KCL = 50pF
Min
Max
Units
TC = +25°C, +125°C
10
1500
ns
TC = -55°C
10
3500
ns
TC = +25°C, +125°C
10
2000
ns
TC = -55°C
10
5000
ns
tONEN
RL = 1K, CL = 50pF
10
1500
ns
tOFFEN
RL = 1K, CL = 50pF 1/
10
1000
ns
Notes:
1/ +VEE = +11.4 Vdc, -VEE = -11.4 Vdc and VREF = 5.0 V
SCD8507 Rev C 5/5/14
5
Aeroflex Plainview
TRUTH TABLE (CH0 – CH15)
TRUTH TABLE (CH16 – CH31)
B3
B2
B1
B0
EN(0-15)
"ON" CHANNEL 1/
B3
B2
B1
B0
EN(16-31)
"ON" CHANNEL 1/
X
X
X
X
H
NONE
X
X
X
X
H
NONE
L
L
L
L
L
CH0
L
L
L
L
L
CH16
L
L
L
H
L
CH1
L
L
L
H
L
CH17
L
L
H
L
L
CH2
L
L
H
L
L
CH18
L
L
H
H
L
CH3
L
L
H
H
L
CH19
L
H
L
L
L
CH4
L
H
L
L
L
CH20
L
H
L
H
L
CH5
L
H
L
H
L
CH21
L
H
H
L
L
CH6
L
H
H
L
L
CH22
L
H
H
H
L
CH7
L
H
H
H
L
CH23
H
L
L
L
L
CH8
H
L
L
L
L
CH24
H
L
L
H
L
CH9
H
L
L
H
L
CH25
H
L
H
L
L
CH10
H
L
H
L
L
CH26
H
L
H
H
L
CH11
H
L
H
H
L
CH27
H
H
L
L
L
CH12
H
H
L
L
L
CH28
H
H
L
H
L
CH13
H
H
L
H
L
CH29
H
H
H
L
L
CH14
H
H
H
L
L
CH30
H
H
H
H
L
CH15
H
H
H
H
L
CH31
1/ Between CH0-15 and OUTPUT (0-15)
1/ Between CH16-31 and OUTPUT (16-31)
TRUTH TABLE (CH32 – CH47)
TRUTH TABLE (CH48 – CH63)
A3
A2
A1
A0
EN(32-47)
"ON" CHANNEL 1/
A3
A2
A1
A0
EN(48-63)
"ON" CHANNEL 1/
X
X
X
X
H
NONE
X
X
X
X
H
NONE
L
L
L
L
L
CH32
L
L
L
L
L
CH48
L
L
L
H
L
CH33
L
L
L
H
L
CH49
L
L
H
L
L
CH34
L
L
H
L
L
CH50
L
L
H
H
L
CH35
L
L
H
H
L
CH51
L
H
L
L
L
CH36
L
H
L
L
L
CH52
L
H
L
H
L
CH37
L
H
L
H
L
CH53
L
H
H
L
L
CH38
L
H
H
L
L
CH54
L
H
H
H
L
CH39
L
H
H
H
L
CH55
H
L
L
L
L
CH40
H
L
L
L
L
CH56
H
L
L
H
L
CH41
H
L
L
H
L
CH57
H
L
H
L
L
CH42
H
L
H
L
L
CH58
H
L
H
H
L
CH43
H
L
H
H
L
CH59
H
H
L
L
L
CH44
H
H
L
L
L
CH60
H
H
L
H
L
CH45
H
H
L
H
L
CH61
H
H
H
L
L
CH46
H
H
H
L
L
CH62
H
H
H
H
L
CH47
H
H
H
H
L
CH63
1/ Between CH32-47 and OUTPUT (32-47) and CURRENT (32-47)
SCD8507 Rev C 5/5/14
1/ Between CH48-63 and OUTPUT (48-63) and CURRENT (48-63)
6
Aeroflex Plainview
Address Lines
(A0 - A3)
(B0 - B3)
4.0V
50%
0.8V
11.6V MIN
50%
MUX Output
0V
t AHL
Definition of t AHL
Address Lines
(A0 - A3)
(B0 - B3)
4.0V
50%
0.8V
11.6V MIN
MUX Output
50%
0V
t ALH
Definition of t ALH
4.0V
EN Lines
50%
0.8V
~3V to 10.0V
MUX Output
50%
0V
tONEN
tOFFEN
Definition of tONEN and tOFFEN
NOTE: f = 10KHz, Duty cycle = 50%.
MUX8507 SWITCHING DIAGRAMS
SCD8507 Rev C 5/5/14
7
Aeroflex Plainview
PIN NUMBERS & FUNCTIONS
MUX8507 – 96 Leads Ceramic QUAD Flat Pack
Pin #
Function
Pin #
Function
Pin #
Function
1
A2
33
CH11
65
CH49
2
B2
34
CH27
66
CH48
3
A3
35
CH12
67
Output I (48-63)
4
B3
36
CH28
68
Output V (48-63)
5
EN 0-15
37
CH13
69
Output I (32-47)
6
EN 16-31
38
CH29
70
Output V (32-47)
7
CH0
39
CH14
71
GND
8
CH16
40
CH30
72
GND
9
CH1
41
CH15
73
CH47
10
CH17
42
CH31
74
CH46
11
CH2
43
NC
75
CH45
12
CH18
44
+VEE
76
CH44
13
CH3
45
NC
77
CH43
14
CH19
46
-VEE
78
CH42
15
CH4
47
NC
79
CH41
16
CH20
48
VREF
80
CH40
17
CH5
49
NC
81
CH39
18
CH21
50
CASE GND
82
CH38
19
CH6
51
CH63
83
CH37
20
CH22
52
CH62
84
CH36
21
CH7
53
CH61
85
CH35
22
CH23
54
CH60
86
CH34
23
GND
55
CH59
87
CH33
24
GND
56
CH58
88
CH32
25
Output V (0-15)
57
CH57
89
GND
26
Output V (16-31)
58
CH56
90
GND
27
CH8
59
CH55
91
EN 48-63
28
CH24
60
CH54
92
EN 32-47
29
CH9
61
CH53
93
A0
30
CH25
62
CH52
94
B0
31
CH10
63
CH51
95
A1
32
CH26
64
CH50
96
B1
Notes:
1) It is recommended that all "NC or "no connect pin" be grounded. This eliminates or minimizes any ESD or static buildup.
2) Package lid is internally connected to circuit ground (Pins 23, 24, 50, 71, 72, 89 & 90)
SCD8507 Rev C 5/5/14
8
Aeroflex Plainview
ORDERING INFORMATION
Model
DLA SMD #
Screening
Package
MUX8507-7
-
Commercial Flow, +25°C testing only
QUAD
Flat Pack
MUX8507-201-1S
5962-1021201KXC
In accordance with DLA SMD
MUX8507-901-1S
5962F1021201KXC
In accordance with DLA Certified RHA Program Plan to
RHA Level "F", 300krad(Si)
1.150 ±.005
(23 Spaces at .050)
Tol Non-Cum
4 Sides
Pin 1
Pin 12
.200
MAX
Pin 85
Pin 84
Pin 13
.0165
±.003
1.320 SQ
MAX
Pin 36
(.400)
Pin 61
Pin 60
Pin 37
.006
±.001
FLAT PACKAGE OUTLINE
Note: Outside ceramic tie bars
not shown for clarity. Contact
factory for details.
EXPORT CONTROL:
This product is controlled for export under the International Traffic in Arms Regulations (ITAR). A license from the U.S. Government is required
prior to the export of this product from the United States.
www.aeroflex.com/HiRel
[email protected]
Datasheet Definitions:
Advanced
Preliminary
Datasheet
Product in Development
Shipping Non-Flight Prototypes
Shipping QML and Reduced HiRel
Aeroflex Plainview, Inc. reserves the right to make changes to any products and
services described herein at any time without notice. Consult Aeroflex or an authorized
sales representative to verify that the information in this data sheet is current before
using this product. Aeroflex does not assume any responsibility or liability arising out
of the application or use of any product or service described herein, except as expressly
agreed to in writing by Aeroflex; nor does the purchase, lease, or use of a product or
service from Aeroflex convey a license under any patent rights, copyrights, trademark
rights, or any other of the intellectual rights of Aeroflex or of third parties.
SCD8507 Rev C 5/5/14
9
Our passion for performance is defined by three attributes.
Solution-Minded
Performance-Driven
Customer-Focused