MUX8511 (11/08)

Standard Products
ACT8511 64-Channel Analog Multiplexer Module
Radiation Tolerant & ESD Protected
www.aeroflex.com/mux
November 14, 2008
FEATURES
❑
❑
64-channels provided by four 16-channel multiplexers
Radiation performance
- Total dose:
150 krads(Si), Dose rate = 50 - 300 rads(Si)/s
- SEU:
Immune up to 90 MeV-cm2/mg
- SEL:
Immune by process design
❑
Full military temperature range
❑
Low power consumption < 60mW
❑
Two address busses (A0-3 & B0-3) and four enable lines afford flexible organization
❑
All channel inputs are protected by ±20V nominal Transorbs
❑
Fast access time < 500ns typical
❑
Break-Before-Make switching
❑
High analog input impedance (power on or off)
❑
Designed for aerospace and high reliability space applications
❑
Packaging – Hermetic ceramic
- 96 leads, 1.32"Sq x 0.20"Ht quad flat pack
- Typical Weight 15 grams
❑
DSCC SMD 5962-09202 pending
Note: Aeroflex Plainview does not currently have a DSCC certified Radiation Hardened Assurance Program.
GENERAL DESCRIPTION
Aeroflex’s ACT8511 is a radiation tolerant, 64 channel multiplexer MCM (multi-chip module) with
electrostatic discharge (ESD) protection on all channel inputs.
The ACT8511 has been specifically designed to meet exposure to radiation environments. It is available in
a 96 lead High Temperature Co-Fired Ceramic (HTCC) Quad Flatpack (CQFP). It is guaranteed
operational from -55°C to +125°C. Available screened in accordance with MIL-PRF-38534, the ACT8511
is ideal for demanding military and space applications.
ORGANIZATION AND APPLICATION
The ACT8511 consists of four 16 channel multiplexers arranged as shown in the Block Diagram. The
ACT8511 design is inherently radiation tolerant.
A SECTION
Thirty-two (32) channels addressable by bus A0~A3, in two 16 channel blocks, each block enabled
separately.
B SECTION
Thirty-two (32) channels addressable by bus B0~B3, in two 16 channel blocks, each block enabled
separately.
SCD8511 Rev D
SCD8511 Rev D 11/14/08
2
Aeroflex Plainview
+VEE
A0
A1
A2
A3
EN 32-47
CH 47
•
•
•
CH 32
B0
B1
B2
B3
EN 0-15
CH 15
•
•
•
CH 0
16
16
VR
VR
16
16
-VEE
OUTPUT 32-47
CH 31
GND
VREF
EN 48-63
CH 63
•
•
•
CH 48
EN 16-31
SECTION A
OUTPUT 0-15
•
•
•
CH 16
16
16
VR
VR
16
16
ACT8511 64 – CHANNEL ANALOG MUX BLOCK DIAGRAM
MUX 3
MUX 1
SECTION B
MUX 4
MUX 2
OUTPUT 48-63
OUTPUT 16-31
ABSOLUTE MAXIMUM RATINGS 1/
Parameter
Range
Units
Case Operating Temperature Range
-55 to +125
°C
Storage Temperature Range
-65 to +150
°C
+20
-20
+7.5
V
V
V
< VREF +0.5
> GND -0.5
V
V
±18V
V
Supply Voltage
+VEE (Pin 44)
-VEE (Pin 46)
VREF (Pin 48)
Digital Input Overvoltage
VEN (Pins 5, 6, 91, 92), VA (Pins 1, 3, 93, 95), VB (Pins 2, 4, 94, 96)
Analog Input Over Voltage
VS
Notes:
1/ All measurements are made with respect to ground.
NOTICE: Stresses above those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress rating only;
functional operation beyond the "Operation Conditions" is not recommended and extended exposure beyond the "Operation Conditions" may
affect device reliability.
RECOMMENDED OPERATING CONDITIONS 1/
Symbol
Parameter
Typical
Units
+VEE
+15V Power Supply Voltage
+15.0
V
-VEE
-15V Power Supply Voltage
-15.0
V
VREF
Reference Voltage
+5.00
V
VAL
Logic Low Level
+0.8
V
VAH
Logic High Level
+4.0
V
Notes:
1/ Power Supply turn-on sequence shall be as follows: -VEE, VREF, followed by +VEE.
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/
(Tc = -55°C to +125°C, -VEE = -15V, VREF = +5.0V, +VEE = +15V - Unless otherwise specified)
Parameter
Supply Current
Symbol
+IEE
Conditions
VEN(0-63) = VA(0-3)A = VA(0-3)B = 0
2
mA
0
mA
VEN(0-63) = 4V, VA(0-3)A = VA(0-3)B = 0 7/
0
2
mA
-2
0
mA
IAL(0-3)A
VA = 0V
-2
2
μA
IAH(0-3)A
VA = 5V
-2
2
μA
IAL(0-3)B
VB = 0V
-2
2
μA
IAH(0-3)B
VB = 5V
-2
2
μA
IENL(0-15)
VEN(0-15) = 0V
-1
1
μA
IENH(0-15)
VEN(0-15) = 5V
-1
1
μA
IENL(16-31)
VEN(16-31) = 0V
-1
1
μA
IENH(16-31)
VEN(16-31) = 5V
-1
1
μA
IENL(32-47)
VEN(32-47) = 0V
-1
1
μA
IENH(32-47)
VEN(32-47) = 5V
-1
1
μA
IENL(48-63
VEN(48-63) = 0V
-1
1
μA
IENH(48-63)
VEN(48-63) = 5V
-1
1
μA
-ISBY
SCD8511 Rev D 11/14/08
Units
0
+ISBY
Enable Input Current
Max
-2
-IEE
Address Input Current
Min
3
Aeroflex Plainview
DC ELECTRICAL PERFORMANCE CHARACTERISTICS 1/ (continued)
(Tc = -55°C to +125°C, -VEE = -15V, VREF = +5.0V, +VEE = +15V - Unless otherwise specified)
Parameter
Symbol
Conditions
Min
Max
Units
Positive Input Leakage
Current CH0-CH63
+ISOFFOUTPUT
VIN = +10V, VEN = 4V, output and all unused MUX inputs
under test = -10V 2/, 3/
-100
+1000
nA
Negative Input Leakage
Current CH0-CH63
-ISOFFOUTPUT
VIN = -10V, VEN = 4V, output and all unused MUX inputs
under test = +10V 2/, 3/
-100
+1000
nA
Output Leakage Current
OUTPUTS
(pins 25,26, 68 & 70)
+IDOFFOUTPUT
VOUT = +10V, VEN = 4V, output and all unused MUX inputs
under test = -10V 3/, 4/
-100
+100
nA
Output Leakage Current
OUTPUTS
(pins 25,26, 68 & 70)
-IDOFFOUTPUT
VOUT = -10V, VEN = 4V, output and all unused MUX inputs
under test = +10V 3/, 4/
-100
+100
nA
Input Clamped Voltage
CH0 - CH63
+VCLMP
VEN = 4V, all unused MUX inputs under test are
open. 3/
+25°C
+125°C
-55°C
18.0
18.0
17.5
23.0
23.5
22.5
V
V
V
Input Clamped Voltage
CH0 - CH63
-VCLMP
+25°C
+125°C
-55°C
-23.0
-23.5
-22.5
-18.0
-18.0
-17.5
V
V
V
Switch ON Resistance
OUTPUTS
(pins 25,26, 68 & 70)
6/
RDS(ON)(0-63)A
VIN = +15V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/
200
1000
Ω
RDS(ON)(0-63)B
VIN = +5V, VEN = 0.8V, IOUT = -1mA
2/, 3/, 5/
200
1500
Ω
RDS(ON)(0-63)C
VIN = -5V, VEN = 0.8V, IOUT = +1mA
2/, 3/, 5/
200
2500
Ω
Notes:
1/ Measure inputs sequentially. Ground all unused inputs of the device under test. VA is the applied input voltage to the address lines A(0-3). VB is
the applied input voltage to the address lines B(0-3).
2/ VIN is the applied input voltage to the input channels CH0-CH63.
3/ VEN is the applied input voltage to the enable lines En(0-15), En(16-31), En(32-47) and En(48-63).
4/ VOUT is the applied input voltage to the output lines OUTPUT(0-15), OUTPUT(16-31), OUTPUT(32-47) and OUTPUT(48-63).
5/ Negative current is the current flowing out of each of the MUX pins. Positive current is the current flowing into each MUX pin.
6/ The ACT8511 cannot be operated with analog inputs from -15 to -5 volts.
7/ Not tested, guaranteed to the specified limits.
SWITCHING CHARACTERISTICS
(Tc = -55°C to +125°C, -VEE = -15V, VREF = +5.0V, +VEE = +15V -- Unless otherwise specified)
Parameter
Switching Test MUX
Symbol
tAHL
Conditions
RL = 10KΩ, CL = 50pF
tALH
tONEN
RL = 1KΩ, CL = 50pF
tOFFEN
SCD8511 Rev D 11/14/08
4
Min
Max
Units
10
1000
ns
10
1000
ns
10
1000
ns
10
1000
ns
Aeroflex Plainview
TRUTH TABLE (CH0 – CH15)
TRUTH TABLE (CH16 – CH31)
B3
B2
B1
B0
EN(0-15)
"ON" CHANNEL 1/
B3
B2
B1
B0
EN(16-31)
"ON" CHANNEL 1/
X
X
X
X
H
NONE
X
X
X
X
H
NONE
L
L
L
L
L
CH0
L
L
L
L
L
CH16
L
L
L
H
L
CH1
L
L
L
H
L
CH17
L
L
H
L
L
CH2
L
L
H
L
L
CH18
L
L
H
H
L
CH3
L
L
H
H
L
CH19
L
H
L
L
L
CH4
L
H
L
L
L
CH20
L
H
L
H
L
CH5
L
H
L
H
L
CH21
L
H
H
L
L
CH6
L
H
H
L
L
CH22
L
H
H
H
L
CH7
L
H
H
H
L
CH23
H
L
L
L
L
CH8
H
L
L
L
L
CH24
H
L
L
H
L
CH9
H
L
L
H
L
CH25
H
L
H
L
L
CH10
H
L
H
L
L
CH26
H
L
H
H
L
CH11
H
L
H
H
L
CH27
H
H
L
L
L
CH12
H
H
L
L
L
CH28
H
H
L
H
L
CH13
H
H
L
H
L
CH29
H
H
H
L
L
CH14
H
H
H
L
L
CH30
H
H
H
H
L
CH15
H
H
H
H
L
CH31
1/ Between CH0-15 and OUTPUT (0-15)
1/ Between CH16-31 and OUTPUT (16-31)
TRUTH TABLE (CH32 – CH47)
TRUTH TABLE (CH48 – CH63)
A3
A2
A1
A0
EN(32-47)
"ON" CHANNEL 1/
A3
A2
A1
A0
EN(48-63)
"ON" CHANNEL 1/
X
X
X
X
H
NONE
X
X
X
X
H
NONE
L
L
L
L
L
CH32
L
L
L
L
L
CH48
L
L
L
H
L
CH33
L
L
L
H
L
CH49
L
L
H
L
L
CH34
L
L
H
L
L
CH50
L
L
H
H
L
CH35
L
L
H
H
L
CH51
L
H
L
L
L
CH36
L
H
L
L
L
CH52
L
H
L
H
L
CH37
L
H
L
H
L
CH53
L
H
H
L
L
CH38
L
H
H
L
L
CH54
L
H
H
H
L
CH39
L
H
H
H
L
CH55
H
L
L
L
L
CH40
H
L
L
L
L
CH56
H
L
L
H
L
CH41
H
L
L
H
L
CH57
H
L
H
L
L
CH42
H
L
H
L
L
CH58
H
L
H
H
L
CH43
H
L
H
H
L
CH59
H
H
L
L
L
CH44
H
H
L
L
L
CH60
H
H
L
H
L
CH45
H
H
L
H
L
CH61
H
H
H
L
L
CH46
H
H
H
L
L
CH62
H
H
H
H
L
CH47
H
H
H
H
L
CH63
1/ Between CH32-47 and OUTPUT (32-47)
SCD8511 Rev D 11/14/08
1/ Between CH48-63 and OUTPUT (48-63)
5
Aeroflex Plainview
Address Lines
(A0 - A3)
4.0V
50%
0.8V
11.6V MIN
50%
MUX Output
0V
t AHL
Definition of t AHL
Address Lines
(A0 - A3)
4.0V
50%
0.8V
11.6V MIN
MUX Output
50%
0V
t ALH
Definition of t ALH
4.0V
EN Lines
50%
0.8V
~3V to 12.5V
MUX Output
50%
0V
tONEN
tOFFEN
Definition of tONEN and tOFFEN
NOTE: f = 10KHz, Duty cycle = 50%.
ACT8511 SWITCHING DIAGRAMS
SCD8511 Rev D 11/14/08
6
Aeroflex Plainview
PIN NUMBERS & FUNCTIONS
ACT8511 – 96 Leads Ceramic QUAD Flat Pack
Pin #
Function
Pin #
Function
Pin #
Function
1
A2
33
CH11
65
CH49
2
B2
34
CH27
66
CH48
3
A3
35
CH12
67
NC
4
B3
36
CH28
68
Output V(48-63)
5
EN 0-15
37
CH13
69
NC
6
EN 16-31
38
CH29
70
Output V(32-47)
7
CH0
39
CH14
71
GND
8
CH16
40
CH30
72
GND
9
CH1
41
CH15
73
CH47
10
CH17
42
CH31
74
CH46
11
CH2
43
NC
75
CH45
12
CH18
44
+VEE
76
CH44
13
CH3
45
NC
77
CH43
14
CH19
46
-VEE
78
CH42
15
CH4
47
NC
79
CH41
16
CH20
48
VREF
80
CH40
17
CH5
49
NC
81
CH39
18
CH21
50
CASE GND
82
CH38
19
CH6
51
CH63
83
CH37
20
CH22
52
CH62
84
CH36
21
CH7
53
CH61
85
CH35
22
CH23
54
CH60
86
CH34
23
GND
55
CH59
87
CH33
24
GND
56
CH58
88
CH32
25
Output V(0-15)
57
CH57
89
GND
26
Output V(16-31)
58
CH56
90
GND
27
CH8
59
CH55
91
EN 48-63
28
CH24
60
CH54
92
EN 32-47
29
CH9
61
CH53
93
A0
30
CH25
62
CH52
94
B0
31
CH10
63
CH51
95
A1
32
CH26
64
CH50
96
B1
NOTE: It is recommended that all "NC" or "no connect pin" be grounded. This eliminates or minimizes any ESD or
static buildup.
SCD8511 Rev D 11/14/08
7
Aeroflex Plainview
ORDERING INFORMATION
Model Number
Screening
DSCC SMD #
Package
ACT8511-S
Military Temperature, -55°C to +125°C,
Screened in accordance with MIL-PRF-38534, Class K
NA
QUAD Flat Pack
ACT8511-7
Commercial Flow, +25°C testing only
ACT8511-201-1S
In accordance with DSCC SMD
FLAT PACKAGE OUTLINE
5962-0920202KXC
1.150 ±.005
(23 Spaces at .050)
Tol Non-Cum
4 Sides
Pin 1
Pin 12
.200
MAX
Pin 85
Pin 84
Pin 13
.0165
±.003
1.320 SQ
MAX
Pin 36
(.400)
Pin 61
Pin 60
Pin 37
.006
±.001
Note: Outside ceramic tie bars
not shown for clarity. Contact
factory for details.
EXPORT CONTROL:
EXPORT WARNING:
This product is controlled for export under the International Traffic in
Arms Regulations (ITAR). A license from the U.S. Department of
State is required prior to the export of this product from the United
States.
Aeroflex’s military and space products are controlled for export under
the International Traffic in Arms Regulations (ITAR) and may not be
sold or proposed or offered for sale to certain countries. (See ITAR
126.1 for complete information.)
PLAINVIEW, NEW YORK
Toll Free: 800-THE-1553
Fax: 516-694-6715
INTERNATIONAL
Tel: 805-778-9229
Fax: 805-778-1980
NORTHEAST
Tel: 603-888-3975
Fax: 603-888-4585
SE AND MID-ATLANTIC
Tel: 321-951-4164
Fax: 321-951-4254
WEST COAST
Tel: 949-362-2260
Fax: 949-362-2266
CENTRAL
Tel: 719-594-8017
Fax: 719-594-8468
www.aeroflex.com
[email protected]
Aeroflex Microelectronic Solutions reserves the right to
change at any time without notice the specifications, design,
function, or form of its products described herein. All
parameters must be validated for each customer's application
by engineering. No liability is assumed as a result of use of
this product. No patent licenses are implied.
Our passion for performance is defined by three
attributes represented by these three icons:
solution-minded, performance-driven and customer-focused
SCD8511 Rev D 11/14/08
8