Datenblatt

For more information, please visit the product page.
date
08/13/2013
page
1 of 5
SERIES: VF-S250-XXA-CF │ description: AC-DC POWER SUPPLY
FEATURES
•
•
•
•
•
•
•
•
•
•
up to 250 W continuous power
600W peak power within 500 µs duty duration
metal top cover and fan
passive power factor correction
power good signal
remote on/off control
3,000 Vac isolation voltage
over load, over voltage, over temperature, and short circuit protections
UL, cUL, and TUV 60950-1 safety approvals
efficiency up to 83%
RoHS
MODEL
output
voltage
output
current
output1
power
ripple and
noise 2,3
efficiency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VF-S250-05A-CF
5
40
200
50
75%
VF-S250-09A-CF
9
25
225
90
83%
VF-S250-12A-CF
12
20.83
250
120
80%
VF-S250-15A-CF
15
16.67
250
150
83%
VF-S250-18A-CF
18
13.89
250
180
83%
VF-S250-24A-CF
24
10.42
250
240
83%
VF-S250-28A-CF
28
8.93
250
280
83%
VF-S250-36A-CF
36
6.93
250
360
83%
VF-S250-48A-CF
48
5.21
250
480
83%
VF-S250-54A-CF
54
4.63
250
540
83%
Notes:
1. Maximum power must not exceed 135 W with convection cooling or 250 W for forced air. 5 and 9 V models maximum current listed.
2. 1% minimum load is required to maintain the ripple and regulation.
3. Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with a 0.1 μF ceramic capacitor and a 22 μF electrolytic capacitor in parallel.
PART NUMBER KEY
VF - S250 - XXA - CF - XX
Base Number
Output Voltage
Low leakage option:
“blank” = standard specification
L = low leakage (contact factory)
Input/Output connector:
“blank” = Terminal block input / Terminal block output
1 = Molex input / Molex output
2 = Molex input / Terminal block output
3 = Terminal block input / Molex output
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VF-S250-XXA-CF │ description: AC-DC POWER SUPPLY
date 08/13/2013 │ page 2 of 5
input
parameter
conditions/description
voltage
90-132/180-264 auto selectable
min
frequency
max
units
90/180
typ
132/264
Vac
47
63
Hz
6
3
A
A
35
70
A
A
current
at 110~120 Vac, cold start
at 200~240 Vac, cold start
inrush current
at 115 Vac, cold start
at 230 Vac, cold start
power factor
compliant to EN 61000-3-2 class A
remote on/off
designated as RMSW on the CN1, requires a low signal to inhibit output, hiccup mode
output
parameter
conditions/description
min
line regulation
low line to high line
±1
%
load regulation
all other outputs
±1
%
0.25
mV/°C
temperature coefficient
typ
transient response
output voltage returns to within 1% in less than 2.5 ms for a 50% load change.
peak transient does not exceed 5%.
start-up time
at 120 Vac
rise time
hold-up time
0.2
at 120 Vac and 80% of rated maximim load
max
1
s
20
ms
20
adjustability
units
ms
±5
power good
designated as PG on the CN1, signal goes high 100-500 ms after the output
reaches regulation, signal goes low at least 1 ms before loss of regulation.
fan drive
12 Vdc / 300 mA for external fan
%
ProtectioNs
parameter
conditions/description
min
typ
max
units
over voltage protection
AC input needs to be reset to restart the power supply
over current protection
automatically recovers
130
%
110
140
%
short circuit protection
short circuit can be continuous, recovers automatically upon removal of short
over temperature protection
auto recovery
85
°C
max
units
safety & compliance
parameter
conditions/description
isolation voltage
applied for 3 seconds at 10 mA max.
primary to secondary
primary to transformer core
primary to earth chassis
min
safety approvals
UL 60950-1, CSA C22.2 No. 60950-1, TUV EN 60950-1 and CB
EMI/EMC
CISPR 22/EN 55022 class B, EN 61000-3-2, 3,
EN 61000-4-2, 3, 4, 5, 6, 8, 11, EN 55024 CE marked (LVD)
leakage current
at 240 Vac, (optional for 500 µA at 240 Vac,
300 µA at 120 Vac)
MTBF
according to MIL-HDBK-217 at 30 ºC
RoHS compliant
yes
cui.com
typ
3,000
1,500
1,500
Vac
Vac
Vac
1.5
100,000
mA
hrs
For more information, please visit the product page.
CUI Inc │ SERIES: VF-S250-XXA-CF │ description: AC-DC POWER SUPPLY
date 08/13/2013 │ page 3 of 5
environmental
parameter
conditions/description
min
operating temperature
typ
0
storage temperature
max
units
70
°C
-20
85
°C
operating humidity
non-condensing
5%
90%
%
storage humidity
non-condensing
5%
95%
%
vibration
acceleration ± 7.35 M/(SxS), on X, Y and Z Axis
5
50
Hz
DERATING CURVES
output power vs. ambient temperature
Load (%)
100
80
60
50
40
20
0
10
20
30
40
50
60
70
Ambient Temperature (°C)
mechanical
parameter
conditions/description
dimensions
5(L) x 3.2(W) x 2(H)
min
typ
max
units
inches
weight
500
cui.com
g
For more information, please visit the product page.
CUI Inc │ SERIES: VF-S250-XXA-CF │ description: AC-DC POWER SUPPLY
date 08/13/2013 │ page 4 of 5
MECHANICAL DRAWING
units: mm[inches]
tolerance: ±0.3mm
UNLESS OTHERWISE SPECIFIED
50.80 2.000
6.35 0.250
6.35 0.250
19.05 0.750
13.90 0.547
(2 PLCS)
68.58 2.700
(2 PLCS)
mounting hole
M3x0.5 (7 PLCS)
44.52 1.753
(2 PLCS)
LED
FAN
64.76 2.550
CN1
1
ground
2
ac neutral
3
ac line
CN2
Vo+
2
Vo+
3
Vo+
4
Vo-
5
Vo-
6
Vo-
VO-
FG
CN2
NEUTRAL
VO+
LINE
molex part no.
26-48-1061
(6 pins)
molex part no.
26-48-1051
(5 pins, 3 used)
8.26 0.325
1
CN3
CN1
terminal block
M3 screw
3pins 6.35mm center
terminal block
M3 screw
4pins 6.35mm center
50.80 2.000
CN3
1
Power Good
2
remote switch
3
RTN
Notes:
1.
2.
3.
4.
5.
81.28 3.200
RTN
RMSW
P.G
127.00 5.000
CN1 mates with molex part no. 09-93-0500 and molex 2478, 2578, 8818 crimp pins.
CN2 mates with molex part no. 09-93-0600 and molex 2478, 2578, 8818 crimp pins.
CN3 mates with JST part no. XHP-3 or equivalent (Chyao Shiunn JS-2001-03) and JST SXH-002T-P0.6 mating pins
Fan drive connector mates with JST part no. XHP-2 or equivalent
Mounting hole maximum M3 screw depth 3.8mm
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VF-S250-XXA-CF │ description: AC-DC POWER SUPPLY
date 08/13/2013 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
05/5/2009
1.01
new template applied
12/17/2011
1.02
V-Infinity branding removed
08/28/2012
1.03
updated Molex mating connector part numbers
07/18/2013
updated spec
08/13/2013
1.04
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.