SPO-2013-PIN-0002

AEROFLEX DATA EXCHANGE PROGRAM TRANSMITTAL
PRODUCT INFORMATION NOTICE
1. TITLE
2. DOCUMENT NUMBER
MICROCIRCUIT, MEMORY, DIGITAL, CMOS, 4MEG X
39BIT(160M), RADIATION-HARDENED, DUAL VOLTAGE
SRAM, MULTICHIP MODULE
SPO-2013-PIN-0002
3. DATE (Year, Month, Date)
2013, JAN, 22
4. MANUFACTURER NAME AND ADDRESS
5. MANUFACTURER POINT OF CONTACT NAME
AEROFLEX COLORADO SPRINGS, INC.
MIKE LESLIE
4350 CENTENNIAL BOULEVARD
COLORADO SPRINGS, COLORADO 80907-3486
6. MANUFACTURER POINT OF CONTACT TELEPHONE
(719) 594-8148
7. MANUFACTURER POINT OF CONTACT EMAIL
[email protected]
8. CAGE CODE
9. BLANK
10. PRODUCT IDENTIFICATION CODE
11. BASE PART
65342
QS15
UT8R4M39
12. BLANK
13. SMD NUMBER
14. DEVICE TYPE DESIGNATOR
10207
01, 02
15. RHA LEVELS
16. QML LEVEL
R
ALL
17. NON QML LEVEL
18. BLANK
HiRel
19. DESCRIPTION (FOR NEW PRODUCTS, PROVIDE AVAILABILITY DATE AND LEAD TIME)
This notification serves to inform our customers of the reduced dynamic ambient burn-in temperature (TA)
used in the manufacturing process (reference MIL-STD-883 method 1015 test condition D) for the Aeroflex
Colorado Springs SMD products listed above.
The combined effects of thermal impedance from die junction to the burn-in ambient environment (Theta-JA)
and the aggregate thermal power dissipation of the eight (8) dice contained in each module, require Aeroflex to
use a 115°C ambient burn-in temperature to keep the die junctions below their rated absolute maximum
temperature of 150°C.
Although Aeroflex applies burn-in TA at 115⁰C, the burn-in temperature exceeds the device’s rated operating
case temperature (TC) of 105°C, ensuring significant stress margin compared to the use condition. Furthermore,
Aeroflex applies the MIL-STD-883, Method 1015 regression table to determine the appropriate burn-in
duration for TA = 115°C. The final result is a burn-in stress condition that is well above the use conditions and
a stress that is applied to each Device Under Test (DUT) for a significantly longer duration than military
temperature rated devices burned-in at TA = 125°C will receive.
Also note that section 4.2.1 Additional criteria for device classes Q and V in the Standard Microcircuit
Drawing 5962-10207 indicates the 115⁰C ambient burn-in temperature.
NOTE: THIS DOCUMENT IS PUBLISHED FOR INFORMATION PURPOSES AND MAY PROVIDE FORWARD
LOOKING STATEMENTS THAT ARE SUBJECT TO CHANGE. THE USERS SHOULD CONTACT THEIR LOCAL
AEROFLEX SALES OFFICE FOR ANY ACTIONABLE CONTENT DESCRIBED HEREIN.
20. ADEPT REPRESENTATIVE
Timothy L. Meade
ADEPT PIN FORM
21.
SIGNATURE
22.
DATE
23 January 2013