KBP3005 310

KBP3005-310
3 Amp Bridge Rectifier 50 to 1000 Volts
Features
• Surge overload ratings 80 amperes peak
• Ideal for printed circuit board
• RoHS compliant package
Packing & Order Information
500/Box
Graphic symbol
Maximum Ratings
Device
Marking
Maximum
Recurrent
Peak
Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
KBP3005
KBP3005
50V
35V
50V
KBP301
KBP301
100V
70V
100V
KBP302
KBP302
200V
140V
200V
KBP304
KBP304
400V
280V
400V
KBP306
KBP306
600V
420V
600V
KBP308
KBP308
800V
560V
800V
KBP310
KBP310
1000V
700V
1000V
MCC
Catalog
Number
Publication Order Number: [KBP3005-310]
© Bruckewell Technology Corporation Rev. A -2014
KBP3005-310
3 Amp Bridge Rectifier 50 to 1000 Volts
Electrical Characteristics @ 25°C Unless Otherwise Specified
Symbol
Parameter
Test Conditions
Unit
IF(AV)
Average Forward Current
TA = 25°C
3.0A
IFSM
Peak Forward Surge Current
8.3ms, half sine
80A
VF
Maximum Forward Voltage Drop Per Element
IFM = 1.0A per element
TA = 25°C
IR
Maximum DC Reverse Current At
TJ = 25°C
Rated DC Blocking Voltage
TJ = 100°C
1.1V
10μA
■RATINGS AND CHARACTERISTIC CURVES
FIG.1 –FORWARD DERATING CURVE
FIG.2 –DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
FIG.3 –TYPICAL FORWARD
CHARACTERISTICS
FIG.4 –MAXIMUM FORWARD SURGE
CURRENT
Publication Order Number: [KBP3005-310]
© Bruckewell Technology Corporation Rev. A -2014
KBP3005-310
3 Amp Bridge Rectifier 50 to 1000 Volts
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE
WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Bruckewell Technology Inc., its affiliates, agents, and employees, and all persons acting on its or
their behalf (collectively, “Bruckewell”), disclaim any and all liability for any errors, inaccuracies or
incompleteness contained in any datasheet or in any other disclosure relating to any product.
Bruckewell makes no warranty, representation or guarantee regarding the suitability of the products
for any particular purpose or the continuing production of any product. To the maximum extent
permitted by applicable law, Bruckewell disclaims
(i) Any and all liability arising out of the application or use of any product.
(ii) Any and all liability, including without limitation special, consequential or incidental damages.
(iii) Any and all implied warranties, including warranties of fitness for particular purpose,
non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on
Bruckewell’s knowledge of typical requirements that are often placed on Bruckewell products in
generic applications.
Such statements are not binding statements about the suitability of products for a particular
application. It is the customer’s responsibility to validate that a particular product with the properties
described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance
may vary over time.
Product specifications do not expand or otherwise modify Bruckewell’s terms and conditions of
purchase, including but not limited to the warranty expressed therein.
Publication Order Number: [KBP3005-310]
© Bruckewell Technology Corporation Rev. A -2014