GBU15J-U1(GBU(R))2015.08_h 02

GBUϭϱJ-U1
ϭϱA GLASS PASSIVATED h>dZ>Kts&BRIDGE RECTIFIERS - 600V
PRIMARY CHARACTERISTICS
VRRM
600V
I(AV)
15.0A
VF
0.89V
I2t
200A2s
TJ,Max
150℃
GBU(R)
PACKAGE
.
● Body Marking : GBU15J
UL Mark
Logo
Marking Code
VYM
Date Code
.
15J
GBU
Positive Electrodes
V:Product Line Code
Y:1-digit BC year code, 4-2014,5-2015…etc
..
M:Month Code, Ex : 1-1,2-2,---10-O,11-N,12-D
:ULTRA LOW VF
FEATURES
MECHANICAL DATA
Surge overload rating -240 amperes

Case:Molded plastic,GBU(R)
peak

Polarity:Shown above

Ideal for printed circuit board

Terminals :Plated terminals,

Reliable low cost construction utilizing
solderable per MIL-STD-750,Method
molded plastic technique
2026


Moisture Sensitivity Level 1

Epoxy : UL94-V0 rated flame
retardant
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25℃ ambient temperature unless otherwise specified.
Single phase, half wave ,60Hz, resistive or inductive load.
For capacitive load, derate current by 20%
CHARACTERISTICS
SYMBOL
GBU15J-U1
UNIT
VRRM
600
V
Maximum RMS Voltage
VRMS
420
V
Maximum DC Blocking Voltage
VDC
600
V
Maximum Recurrent Peak Reverse Voltage
Maximum Average Forward (with heatsink Note 2)
Rectified Current
@ T C=100℃ (without heatsink)
Peak Forward Surge Current
I(AV)
15.0
A
3.2
IFSM
240
A
Typical Forward Voltage at 7.5A DC
VF
0.89
V
Maximum Forward Voltage at 7.5A DC
VF
0.9
V
8.3ms Single Half Sine-Wave
Super Imposed on Rated Load (JEDEC Method)
Maximum DC Reverse Current
@ TJ=25℃
at Rated DC Blocking Voltage
@ T J=125℃
IR
10.0
500
μA
I2t Rating for Fusing (t<8.3ms)
I2t
200
A2s
Typical Junction Capacitance Per Element (Note1)
CJ
70
pF
RθJC
2.2
℃/W
TJ
-55 to +150
℃
TSTG
-55 to +150
℃
Typical Thermal Resistance
Operating Temperature Range
Storage Temperature Range
NOTES: 1.Measured at 1.0MHz and applied reverse voltage of 4.0V DC.
2.Device mounted on 100mm*100mm*1.6mm Cu plate heatsink.
2015.08
www.willas.com.tw
Rev.h02
P1
GBUϭϱJ-U1
ϭϱA GLASS PASSIVATED h>dZ>Kts&BRIDGE RECTIFIERS - 600V
FIG.2- DERATING CURVE
OUTPUT RECTIFIED CURRENT
400
350
300
250
200
150
100
50
0
10
NUMBER OF CYCLETS AT 60Hz
1
100
AVERAGR FORWARD OUTPUT CURRENT
AMPERES
PEAK FORWARD SURGE CURRENT
AMPERES
FIG.1-MAXIMUM FORWARD SURGE CURRENT
40
30
20
10
0
50
100
150
CASE TEMPERATURE,℃
FIG.3-TYPICAL FORWARD CHARACTERISTICS
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
20.0
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
INSTANTANEOUS FORWARD CURRENT,
AMPERES
10.0
1.0
TJ = 25°C
PULSE WIDTH 300us
0.1
0.01
0
0.2
0.4
0.6
0.8
1.0
1.2
INSTANTANEOUS FORWARD VOLTAGE. VOLTS
2015.08
1.4
10
1.0
TJ=25°C
0.1
0.01
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE
www.willas.com.tw
Rev.h02
P2
GBUϭϱJ-U1
ϭϱA GLASS PASSIVATED h>dZ>Kts&BRIDGE RECTIFIERS - 600V
Outline Drawing
GBU(R)
.437(11.1)
.430(10.9)
.126(3.2)*45°
CHAMFER
.874(22.2)
.860(21.8)
.161(4.1)
.134(3.4)
.752(19.1)
.720(18.3)
.232(5.9)
.213(5.4)
.401(10.2)
.392(9.80)
.073(1.85)
.057(1.45)
.100(2.54)
.085(2.16)
.720(18.29)
.680(17.27)
.047(1.2)
.035(0.9)
.080(2.03)
.065(1.65)
.210
.190
(5.3)
(4.8)
.210
.190
(5.3)
(4.8)
.210
.190
(5.3)
(4.8)
.106(2.7)
.091(2.3)
.022(.56)
.018(.46)
Dimensions in inches and (millimeters)
2015.08
.139(3.53)
.133(3.37)
www.willas.com.tw
Rev.B-1
Rev.h02
P3
GBUϭϱJ-U1
ϭϱA GLASS PASSIVATED h>dZ>Kts&BRIDGE RECTIFIERS - 600V
Ordering Information:
Device PN
GBU15J-U1 (1)G(2)-WS
Packing
Tube Packing:20pcs/Tube; 1000pcs/Box
Note: 1. Packing code: Empty is Tube Packing
2. RoHS product for packing code suffix ”G”, Halogen free product for packing code suffix "H" .
***Disclaimer***
WILLAS reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. WILLAS or anyone on its behalf assumes no responsibility or liability
for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters
which may be included on WILLAS data sheets and/ or specifications can
and do vary in different applications and actual performance may vary over time.
WILLAS does not assume any liability arising out of the application or
use of any product or circuit.
This is the preliminary specification. WILLAS products are not designed, intended or
authorized for use in medical, life-saving implant or other applications intended for
life-sustaining or other related applications where a failure or malfunction of component
or circuitry may directly or indirectly cause injury or threaten a life without expressed
written approval of WILLAS. Customers using or selling WILLAS components for use in
such applications do so at their own risk and shall agree to fully indemnify WILLAS Inc
and its subsidiaries harmless against all claims, damages and expenditures.
2015.08
www.willas.com.tw
Rev.h02
P4