DATA SHEET GBU10A THRU GBU10M SEMICONDUCTOR 10 Amp Single Phase Glass Passivated Bridge Rectifiers 50 to 1000 Volts GBU FEATURES Unit:inch(mm) 0.140 (3.56) 0.130 (3.30) 0.880 (22.3) •Plastic Material has Underwriters Laboratory 0.020 R (TYP.) 0.860 (21.8) 0.125 (3.2) x 45o •Glass Passivated Chip junction 9o TYP. CHAMFER 0.160 (4.1) 0.140 (3.5) 0.310 (7.9) 0.290 (7.4) •High Surge Overload Rating 0.740 (18.8) •Reliable Low Cost Construction Utilizing Molded Plastic Technique 0.720 (18.3) O •High temperature soldering : 260 C / 10 seconds at terminals 0.075 (1.9) R. 0.085 (2.16) 0.065 (1.65) •Pb free product at available : 99% Sn above meet RoHS 0.080 (2.03) 0.060 (1.52) 5o TYP. environment substance directive request 0.085 (2.16) 0.710 (18.0) Maximum Ratings 0.690 (17.5) 0.100 (2.54) 0.085 (2.16) •Operating Temperature: -55℃ to +150℃ 0.075 (1.90) 0.050 (1.27) 0.040 (1.02) •Storage Temperature: -55℃ to +150℃ •Typical Thermal Resistance:2.2℃/W Junction to Case(Heatsink) Maximum MCC Recurrent Maximum Part Number Peak Reverse RMS Voltage Voltage GBU10A 50V 0.080 (2.03) 0.065 (1.65) 0.022 (0.56) 0.018 (0.46) 0.190 (4.83) 0.210 (5.33) Maximum DC Dimensions in inches and (millimeters) Blocking Voltage 35V 50V 100V GBU10B 100V 70V GBU10D 200V 140V 200V GBU10G 400V 280V 400V GBU10J 600V 420V 600V GBU10K 800V 560V 800V GBU10M 1000V 700V 1000V Electrical Characteristics @ 25℃ Unless Otherwise Specified Maximum Average IF(AV) 10 A TA = 100℃ IFSM 200A 8.3ms, half sine VF 1.1V Forward Current (with heatsink Note1) Peak Forward Surge Current Maximum At 5.0/7.5/12.5/ 17.5A DC Instantaneous Forward Voltage Maximum DC IR Reverse Current At 5.0uA TA = 25℃ 500uA TA = 125℃ Rated DC Blocking Voltage Typical Junction CJ Capacitance 70pF Measured at 1.0MHz, VR=4.0V I2t Rating for Fusing I2t 200A2S t<8.3ms Note:1.Device mounted on 100mm × 100mm × 1.6mm Cu Plate Heatsink http://www.yeashin.com 1 REV.02 20120305 DEVICE CHARACTERISTICS GBU10A THRU GBU10M Figure2 Derating Curve Output Rectified Current Figure1 Maximum Forward Surge Current 300 60 250 50 200 40 Amps Amps 150 30 100 20 50 10 0 0 100 10 1 50 0 100 150 Peak Forward Surge Current - Amperes versus Number of Cycles At 60 Hz Peak Forward Surge Current - Amperes versus Number of Cycles At 60 Hz Figure 4 Typical Reverse Characteristics Figure 3 Typical Forward Characteristics 100 100 10 10 µAmps 1.0 Amps 1.0 TJ=25℃ 0.03 0.1 0.01 .4 0.01 20 .6 .8 1.0 1.2 1.4 1.6 60 80 100 120 140 Volts Volts Instantaneous Reverse Current - MicroAmperes versus Percent of Rated Peak Reverse Voltage - Volts Instantaneous Forward Current -Amperes versus Instantaneous Forward Voltage - Volts http://www.yeashin.com 40 2 REV.02 20120305