Test Procedure for the NCP370GEVB Evaluation Board
Test Procedure:
1. Place /REV strap and /DIR strap on left side (“1” logic) (connected to Vbat,
through pull up resistor)
2. Let Battery strap opened.
3. Connect a Battery or power supply (4.2V) on Battery test point. (min 2A
capability)
1/27/2010
1 of 5
www.onsemi.com
4. Connect strap on Ilim.
1/27/2010
2 of 5
www.onsemi.com
5. Select I limit threshold with pull down resistors connected on pin 7:
SW1
0
0
1
1
SW2
0
1
0
1
I OCP
500mA
1A
1.5A
1.5A
R1= 70K
R2= 14K
Disable Mode:
6. Connect 10 V capability Vin Supply on IN1 test point.
a. Set power supply to 5V Ö Check Vout = 0V and LED = off
1/27/2010
3 of 5
www.onsemi.com
Direct Mode:
7. Switch /DIR from left to right, 1 logic level to 0 logic level
8. Check Vout=5V and Flag LED is still off
9. Set Vin=7V
10. Check Flag LED = on, and Vout is 0V.
11. Switch /REV from left to right, 1 logic level to 0 logic level
1/27/2010
4 of 5
www.onsemi.com
12. Check Flag LED = off, and Vout = Vin = 7V.
Disconnect Vin supply
Reverse Mode:
13. Connect Set /DIR=1, /REV=1
Disconnect Vin Power Supply from IN test points.
Connect accessory on IN1 or IN2 test points.
Put strap to connect Battery to Vout
14. Set /DIR=1, /REV=0: Vout= Vin
If I accessory < I limit then Vin = Vout – Rdson x I
If I accessory > I limit then Vin = 0 (Current regulation)
Power off.
15. Set /DIR=1, /REV=1
16. Disconnect accessory
17. Disconnect Battery
1/27/2010
5 of 5
www.onsemi.com