Moisture Sensitivity

Moisture Sensitivity
Introduction
Microsemi tests and classifies all semiconductor devices for moisture sensitivity to ensure long-term
reliability. This document briefly describes moisture-related failure modes, preventative test procedures,
and moisture sensitivity of Microsemi FPGAs. Microsemi tests all of its packaged devices in accordance
with the procedures outlined by JEDEC (IPC/JEDEC JSTD- 020 and JESD22-A113).
Moisture-Induced Manufacturing Failures
Improper storage, handling, or packaging of plastic encapsulated semiconductor devices can allow the
introduction of moisture. Moisture trapped inside plastic encapsulated packages can damage them during
soldering, as the moisture vaporizes and tries to expand. This internal vapor pressure can cause
separation of the plastic package from the semiconductor chip or lead frame, internal or external cracks,
and damage to thin films and wirebonds. In severe cases, soldering may even cause an integrated circuit
to bulge and/or explode.
It is important to handle dry pack bags very carefully to prevent plastic packages from absorbing moisture.
Microsemi strongly recommends adhering to the following guidelines when handling these devices (refer to
IPC/JEDEC STD-033 for more information):
1. Moisture barrier bags are sealed at Microsemi. These bags must be handled with care to avoid
puncture or tearing of the bag's material.
2. Upon receipt, moisture barrier bags should be inspected for punctures or holes of any kind. If
openings in the bag are found and the maximum humidity indicator has been exceeded,
Microsemi recommends baking the parts according to the conditions specified in Table 1 on
page 2.
3. Bags should remain sealed until parts are ready to be used.
4. Inspect the humidity indicator card (HIC) immediately after opening the package and evaluate the
colors of the dots. The HIC card color should be blue (dry).
5. Proper handling of storage, board mounting assembly and rework is critical to avoid over-exposure
of the package to moisture.
Moisture Sensitivity Ranges
JEDEC has defined a moisture sensitivity classification that is universally regarded as the standard for
definitions in this area. The purpose of this standard is to identify the moisture sensitivity level at a fixed
reflow temperature (shown in Table 1 on page 2), so that the user can properly store and handle the
devices and to avoid subsequent thermal/mechanical damage during the assembly reflow attachment
and/or repair operations.
The present moisture sensitivity standard contains seven levels. The lower the level, the longer a device’s
floor life. The goal of all package manufacturers is to have their packages reach level 1, which would be an
unlimited floor life.
March 2011
Table 1: JEDEC Standard Qualification Levels
Level
Description
Preconditioning Followed by Three
Cycles of VPR or IR Solder Shock
Expected Floor Life (at 30°C / 60% RH)
1
Not moisture sensitive
168 hours at 85°C/85% RH
Unlimited
2
Limited moisture sensitive
168 hours at 85°C/60% RH
One year
3
Moisture sensitive
192 hours at 30°C/60% RH
Seven days
4
Moisture sensitive
84 hours at 30°C/60% RH
Three days
5
Highly moisture sensitive
168 hours at 85°C/85% RH
One day
6
Extremely moisture sensitive
168 hours at 85°C/85% RH
Six hours
Typically, most packaged ICs are certified at level 3. This means they have a floor life of 168 hours before
they need to be rebaked.
Moisture Test Method
Consistent with JEDEC recommendations, Microsemi’s tests follow the latest revision of IPC/JEDEC
J-STD-020 (consult JEDEC for the full profile).
Table 2: Moisture Sensitivity Levels for Microsemi Packages
Maximum Exposure Time to Ambient
Condition Prior to Surface
Bake Time at 125°C
Moisture Level
BG/BGG 272/329/456/729
168 hours
8 hours
Level 3
FG/FGG 144/256/324/484/676/896/1152
168 hours
8 hours
Level 3
VF 49/128/180/289
168 hours
8 hours
Level 3
CSG 81/196/201/281
168 hours
8 hours
Level 3
uCG 81
168 hours
8 hours
Level 3
1 year
8 hours
Level 2
QNG 68
168 hours
8 hours
Level 3
RQ 208/240
72 hours
8 hours
Level 4
PQ/PQG 100/144/160/208/240
168 hours
8 hours
Level 3
TQ/TQG 64/100/144/176
168 hours
5 hours
Level 3
VQ/VQG 80/100
168 hours
5 hours
Level 3
PL/PLG 44/68/84
168 hours
8 hours
Level 3
Package Type
QNG 108/132/180
A device is considered a JEDEC failure if it exhibits any of the following:
1. External crack visible under 40X optical microscope
2. Any internal crack that extends more than two-thirds of the distance from the crack initiation to
bonding fingers or package surface
3. Electrical room temperature DC or functional failure. If failure analysis can show that the electrical
failure is not due to moisture-stress sensitivity (for example, electrical overstress), then that failure
may be disallowed. If more than one failure is disallowed, that subgroup must be rerun.
4. Complete delamination on top of a die is verified by a scanning acoustic microscope.
2
Moisture Sensitivity
Conclusion
Moisture trapped inside plastic packages can damage them during soldering. Microsemi tests all plastic
packaged FPGAs for moisture sensitivity according to the procedures outlined by JEDEC. Most of
Microsemi’s plastic packages are rated at a moisture sensitivity level (MSL) of 3. Microsemi’s eX FPGAs,
offered in 0.8 mm chip-scale (CS) plastic packages, are rated at an MSL of 2, which means they can be
stored at room temperature and 85% relative humidity for up to one year. If a user has stored any device
beyond the floor life at or above recommended temperature relative humidity, Microsemi recommends the
user adhere to JEDEC guidelines and perform a bake-out before reflow soldering (Table 1 on page 2).
List of Changes
The following table lists critical changes that were made in each revision of the document.
Revision
51700045-4/3.11
Change
Table 2: Moisture Sensitivity Levels for Microsemi Packages was revised to change
the CSG 49/128/180 package type row to VF 49/128/180/289.
Page
2
The CSG 81/196/201/281/289 package type row was changed to CSG
81/196/201/281.
The moisture level was changed from 2 to 3 for VF 49/128/180/289, CSG 81/196/201,
and uCG81.
The maximum exposure time was changed from 1 year to 168 hours for VF
49/128/180/289, CSG 81/196/201, and uCG81.
51700045-3/1.09
CS289 and QN68 data were added to Table 2: Moisture Sensitivity Levels for
Microsemi Packages.
2
51700045-2/11.08
CSG 281 level 2 was removed from Table 2: Moisture Sensitivity Levels for Microsemi
Packages.
2
51700045-1/6.08
In the "Introduction" section, IPC/JEDEC JSTD-020B and JESD22-A113-B were
changed to IPC/JEDEC JSTD- 020 and JESD22-A113.
1
The "Moisture Test Method" section was significantly updated.
2
Table 2: Moisture Sensitivity Levels for Microsemi Packages was updated to include
the following packages:
2
CS 81/196/201/281/289
uC 81
QN 68/108/132/180
The pin names in the Package Type column were updated to include G. For example,
BG became BGG.
Moisture Sensitivity
3
Microsemi Corporation (NASDAQ: MSCC) offers the industry’s most comprehensive portfolio of
semiconductor technology. Committed to solving the most critical system challenges, Microsemi’s
products include high-performance, high-reliability analog and RF devices, mixed signal integrated
circuits, FPGAs and customizable SoCs, and complete subsystems. Microsemi serves leading
system manufacturers around the world in the defense, security, aerospace, enterprise,
commercial, and industrial markets. Learn more at www.microsemi.com.
Microsemmi Corporate Headquarters
2381 Morse Avenue, Irvine, CA 92614
Phone: 949-221-7100·Fax: 949-756-0308
www.microsemi.com
© 2011 Microsemi Corporation. All rights reserved. Microsemi and the Microsemi logo are trademarks of Microsemi
Corporation. All other trademarks and service marks are the property of their respective owners.
51700045-4/3.11