Bulletin PD-20768 rev. C 09/04 30CTH02 30CTH02S 30CTH02-1 30CTH02FP Hyperfast Rectifier Features • • • • trr =30ns max. IF(AV) = 30Amp VR = 200V Hyperfast Recovery Time Low Forward Voltage Drop Low Leakage Current 175°C Operating Junction Temperature Description/ Applications International Rectifier's 200V series are the state of the art Hyperfast recovery rectifiers specifically designed with optimized performance of forward voltage drop and hyperfast recovery time. The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as free-wheeling diode in low voltage inverters and chopper motor drives. Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers. Absolute Maximum Ratings Parameters VRRM Peak Repetitive Reverse Voltage IF(AV) Average Rectified Forward Current @ TC = 159°C Per Diode Max Units 200 V 15 A @ TC = 125°C (FULLPACK) Per Diode Per Device IFSM Non Repetitive Peak Surge Current @ TJ = 25°C TJ, TSTG Operating Junction and Storage Temperatures 30 200 - 65 to 175 °C Case Styles 30CTH02 30CTH02S Base Common Cathode 30CTH02-1 Base Common Cathode 2 30CTH02FP Base Common Cathode 2 2 2 1 1 Anode 2 Common Cathode 3 Anode TO-220AB www.irf.com 1 Anode 2 Common Cathode D2PAK 3 Anode 1 Anode 2 Common Cathode TO-262 3 Anode Common Cathode 3 Anode Anode TO-220 FULLPACK 1 30CTH02, 30CTH02S, 30CTH02-1, 30CTH02FP Bulletin PD-20768 rev. C 09/04 Electrical Characteristics @ TJ = 25°C (unless otherwise specified) Min Typ Max Units Test Conditions Parameters VBR, Vr Breakdown Voltage, Blocking Voltage VF Forward Voltage IR 200 Reverse Leakage Current - - V IR = 100µA - 0.92 1.05 V IF = 15A, TJ = 25°C - 0.78 0.85 V IF = 15A, TJ = 125°C - - 10 µA VR = VR Rated - 5 300 µA TJ = 125°C, VR = VR Rated CT Junction Capacitance - 57 - pF VR = 200V LS Series Inductance - 8 - nH Measured lead to lead 5mm from package body Dynamic Recovery Characteristics @ TC = 25°C (unless otherwise specified) Parameters trr IRRM Qrr Min Typ Max Units Test Conditions Reverse Recovery Time Peak Recovery Current Reverse Recovery Charge - - 35 - - 30 ns IF = 1A, diF/dt = 50A/µs, VR = 30V - 26 - TJ = 25°C - 40 - TJ = 125°C - 2.8 - - 6.0 - - 37 - - 120 - IF = 1A, diF/dt = 100A/µs, VR = 30V A IF = 15A diF/dt = 200A/µs TJ = 25°C TJ = 125°C nC VR = 160V TJ = 25°C TJ = 125°C Thermal - Mechanical Characteristics Parameters Min TJ Max. Junction Temperature Range TStg Max. Storage Temperature Range RthJC c Thermal Resistance, Junction to Case Typ Max Units 175 °C °C/W - - - 65 - 175 Per Diode - - 1.1 Fullpack (Per Diode) - - 3.5 Device Marking 30CTH02 Case Style TO-220 30CTH02S Case Style D2Pak 30CTH02-1 Case Style TO-262 30CTH02FP Case Style Fullpack c Mounting Surface, Flat, Smooth and Greased 2 www.irf.com 30CTH02, 30CTH02S, 30CTH02-1, 30CH02FP Bulletin PD-20768 rev. C 09/04 100 100 150˚C 125˚C 1 100˚C 0.1 75˚C 50˚C 0.01 25˚C 0.001 0.0001 Tj = 175˚C 0 50 100 150 200 Reverse Voltage - VR (V) Fig. 2 - Typical Values of Reverse Current Vs. Reverse Voltage Tj = 125˚C 10 Tj = 25˚C 1000 (pF) T J = 25˚C T Junction Capacitance - C Instantaneous Forward Current - I F (A) Reverse Current - I R (µ A) Tj = 175˚C 10 1 0.4 100 10 0.6 0.8 1 1.2 1.4 0 1.6 Forward Voltage Drop - VFM (V) 50 100 150 200 Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage Fig. 1 - Typical Forward Voltage Drop Characteristics Thermal Impedance Z thJC (°C/W) 10 1 D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 PDM t1 0.1 t2 Single Pulse (Thermal Resistance) Notes: 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc 0.01 0.00001 www.irf.com 0.0001 0.001 0.01 0.1 1 t1, Rectangular Pulse Duration (Seconds) Fig. 4 - Max. Thermal Impedance Z thJC Characteristics 10 3 30CTH02, 30CTH02S, 30CTH02-1, 30CTH02FP Bulletin PD-20768 rev. C 09/04 Thermal Impedance Z thJC (°C/W) 10 D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 1 PDM t1 0.1 t2 Notes: Single Pulse (Thermal Resistance) 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc 0.01 0.00001 0.0001 0.001 0.01 0.1 1 10 t1, Rectangular Pulse Duration (Seconds) Fig. 5 - Max. Thermal Impedance Z thJC Characteristics (FULLPACK) 180 Allowable Case Temperature (°C) Allowable Case Temperature (°C) 180 170 DC 160 Square wave (D = 0.50) 150 Rated Vr applied see note (2) 140 170 160 150 DC 140 130 Square wave (D = 0.50) 120 Rated Vr applied 110 see note (2) 100 0 5 10 15 20 Average Forward Current - I 25 0 5 10 15 20 Average Forward Current - I (A) F(AV) Fig. 6 - Max. Allowable Case Temperature Vs. Average Forward Current 25 (A) F(AV) Fig. 7 - Max. Allowable Case Temperature Vs. Average Forward Current (FULLPACK) Average Power Loss ( Watts ) 25 20 RMS Limit 15 D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5 10 5 DC (2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 8); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR 0 0 5 10 15 20 Average Forward Current - IF(AV) (A) 25 Fig. 8 - Forward Power Loss Characteristics 4 www.irf.com 30CTH02, 30CTH02S, 30CTH02-1, 30CH02FP Bulletin PD-20768 rev. C 09/04 100 1000 IF = 15 A trr ( ns ) Qrr ( nC ) IF = 15 A 100 V R = 390V T J = 125˚C T J = 25˚C V R = 390V T J = 125˚C T J = 25˚C 10 100 10 100 1000 di F /dt (A/µs ) Fig. 9 - Typical Reverse Recovery vs. di F /dt 1000 di F /dt (A/µs ) Fig. 10 - Typical Stored Charge vs. di F /dt Reverse Recovery Circuit VR = 200V 0.01 Ω L = 70µH D.U.T. diF /dt dif/dt ADJUST D G IRFP250 S Fig. 11- Reverse Recovery Parameter Test Circuit www.irf.com 5 30CTH02, 30CTH02S, 30CTH02-1, 30CTH02FP Bulletin PD-20768 rev. C 09/04 3 t rr IF tb ta 0 Q rr 2 I RRM 4 0.5 I RRM di(rec)M/dt 5 0.75 I RRM 1 diFf /dt 1. diF/dt - Rate of change of current through zero crossing 4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr Fig. 13 - Reverse Recovery Waveform and Definitions Outline Table 10.54 (0.41) MAX. 3.78 (0.15) 3.54 (0.14) 1.32 (0.05) 2.92 (0.11) 2.54 (0.10) TERM 2 15.24 (0.60) 14.84 (0.58) 1.22 (0.05) DIA. 6.48 (0.25) 6.23 (0.24) 1 2 3 14.09 (0.55) 3.96 (0.16) 13.47 (0.53) 3.55 (0.14) 2° 0.10 (0.004) 2.04 (0.080) MAX. 1.40 (0.05) Base Common Cathode 2.89 (0.11) 1.15 (0.04) 0.94 (0.04) 2.64 (0.10) 2 0.69 (0.03) 1 2 3 4.57 (0.18) 1 0.61 (0.02) MAX. Anode 2 Common Cathode 3 Anode 4.32 (0.17) 5.08 (0.20) REF. 6 Conforms to JEDEC Outline TO-220AB Dimensions in millimeters and (inches) www.irf.com 30CTH02, 30CTH02S, 30CTH02-1, 30CH02FP Bulletin PD-20768 rev. C 09/04 Outline Table 4.69 (0.18) 4.20 (0.16) 10.16 (0.40) REF. 1.32 (0.05) 1.22 (0.05) 6.47 (0.25) 15.49 (0.61) 93° 6.18 (0.24) 14.73 (0.58) 5.28 (0.21) 2.61 (0.10) 4.78 (0.19) 2.32 (0.09) 0.55 (0.02) 8.89 (0.35) 3X BASE COMMON CATHODE REF. 1.40 (0.055) 1.14 (0.045) 2X 0.46 (0.02) 0.93 (0.37) MINIMUM RECOMMENDED FOOTPRINT 0.69 (0.27) 11.43 (0.45) 2 1 1 2 3 4.57 (0.18) 3 ANODE COMMON ANODE CATHODE 1 2 4.32 (0.17) 2 8.89 (0.35) 17.78 (0.70) 0.61 (0.02) MAX. 5.08 (0.20) REF. 3.81 (0.15) 2.08 (0.08) Conforms to JEDEC Outline D2PAK Dimensions in millimeters and (inches) 2X 2.54 (0.10) 2X BASE COMMON CATHODE 2 1 2 3 ANODE COMMON ANODE CATHODE 1 2 Modified JEDEC outline TO-262 Dimensions in millimeters and (inches) www.irf.com 7 30CTH02, 30CTH02S, 30CTH02-1, 30CTH02FP Bulletin PD-20768 rev. C 09/04 Outline Table 2 1 Anode Common Cathode 3 Anode Conforms to JEDEC Outline TO-220 FULLPACK Dimensions in millimeters and (inches) Tape & Reel Information TRR 1.60 (0.063) 1.50 (0.059) 4.10 (0.161) 3.90 (0.153) FEED DIRECTION 1.85 (0.073) 1.65 (0.065) 1.60 (0.063) 1.50 (0.059) DIA. 0.368 (0.0145) 0.342 (0.0135) 11.60 (0.457) 11.40 (0.449) 15.42 (0.609) 15.22 (0.601) TRL 1.75 (0.069) 10.90 (0.429) 10.70 (0.421) 1.25 (0.049) 24.30 (0.957) 23.90 (0.941) DIA. 4.72 (0.186) 16.10 (0.634) 4.52 (0.178) 15.90 (0.626) FEED DIRECTION 13.50 (0.532) 12.80 (0.504) DIA. 26.40 (1.039) 24.40 (0.961) SMD-220 Tape & Reel When ordering, indicate the part number, part orientation, and the quantity. Quantities are in multiples 360 (14.173) DIA. MAX. 60 (2.362) of 800 pieces per reel for both TRL and TRR. DIA . MIN. Dimensions in millimeters and (inches) 8 www.irf.com 30CTH02, 30CTH02S, 30CTH02-1, 30CH02FP Bulletin PD-20768 rev. C 09/04 Part Marking Information EXAMPLE: THIS IS A 32CTH02 LOT CODE 1789 ASSEMBLED ON WW 19, 2000 IN THE ASSEMBLY LINE "C" INTERNATIONAL RECTIFIER LOGO PART NUMBER DATE CODE ASSEMBLY LOT CODE YEAR 0 = 2000 WEEK 19 LINE C TO-220AB THIS IS A 32CTH02S LOT CODE 8024 ASSEMBLED ON WW 02, 2000 IN THE ASSEMBLY LINE "L" INTERNATIONAL RECTIFIER LOGO DATE CODE ASSEMBLY LOT CODE D2PAK EXAMPLE: THIS IS A 32CTH02-1 LOT CODE 1789 ASSEMBLED ON WW 19, 1999 IN THE ASSEMBLY LINE "C" PART NUMBER INTERNATIONAL RECTIFIER LOGO ASSEMBLY LOT CODE YEAR 0 = 2000 WEEK 02 LINE L PART NUMBER DATE CODE YEAR 9 = 1999 WEEK 19 LINE C TO-262 EXAMPLE: THIS IS A 32CTH02FP LOT CODE 1789 ASSEMBLED ON WW 19, 2000 IN THE ASSEMBLY LINE "C" INTERNATIONAL RECTIFIER LOGO PART NUMBER DATE CODE ASSEMBLY LOT CODE YEAR 0 = 2000 WEEK 19 LINE C FULLPACK www.irf.com 9 30CTH02, 30CTH02S, 30CTH02-1, 30CTH02FP Bulletin PD-20768 rev. C 09/04 Ordering Information Table Device Code 30 C T H 02 -1 TRL 1 2 3 4 5 6 7 1 - Current Rating (30 = 30A) 2 - C = Common Cathode 3 - T = TO-220 4 - H = HyperFast Recovery 5 - Voltage Rating (02 = 200V) 6 - None = TO-220AB 7 S = D2Pak -1 = TO-262 Option FP = TO-220 FULLPACK None = Tube (50 pieces) TRL = Tape & Reel (Left Oriented - for D 2Pak only) TRR = Tape & Reel (Right Oriented - for D 2Pak only) Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 09/04 10 www.irf.com