IRF 32CTQ025

Bulletin PD-20265 rev. B 07/06
32CTQ...
32CTQ...S
32CTQ...-1
32 Amp
SCHOTTKY RECTIFIER
IF(AV) = 30Amp
VR = 25 - 30V
Description/ Features
Major Ratings and Characteristics
Characteristics
Values
Units
IF(AV) Rectangular
30
A
25 - 30
V
The 32CTQ... Schottky rectifier series has been optimized for
low reverse leakage at high temperature. The proprietary
barrier technology allows for reliable operation up to 150° C
junction temperature. Typical applications are in switching
power supplies, converters, free-wheeling diodes, and reverse battery protection.
waveform
VRRM
150° C TJ operation
High purity, high temperature epoxy encapsulation for
enhanced mechanical strength and moisture resistance
IFSM @ tp = 5 μs sine
900
A
VF
@ 15 Apk, TJ = 125°C
0.40
V
TJ
range
- 55 to 150
°C
Low forward voltage drop
High frequency operation
Guard ring for enhanced ruggedness and long term
reliability
Case Styles
32CTQ...
32CTQ... S
Base
Common
Cathode
Base
Common
Cathode
2
1
Anode
2
Common
Cathode
32CTQ... -1
Base
Common
Cathode
2
3
Anode
TO-220
1
Anode
2
Common
Cathode
D2PAK
2
3
Anode
1
Anode
2
Common
Cathode
3
Anode
TO-262
1
32CTQ..., 32CTQ...S, 32CTQ...-1
Bulletin PD-20265 rev. B 07/06
Voltage Ratings
Part number
VR
32CTQ025
Max. DC Reverse Voltage (V)
32CTQ030
25
VRWM Max. Working Peak Reverse Voltage (V)
30
Absolute Maximum Ratings
Parameters
32CTQ Units Conditions
IF(AV) Max. Average Forward Current
* See Fig. 5
30
A
Max. Peak One Cycle Non-Repetitive
900
Surge Current * See Fig. 7
250
EAS
Non-Repetitive Avalanche Energy
13
mJ
IAR
Repetitive Avalanche Current
3
A
IFSM
A
50% duty cycle @ TC = 115° C, rectangular wave form
5μs Sine or 3μs Rect. pulse
10ms Sine or 6ms Rect. pulse
Following any rated
load condition and
with rated VRRM applied
TJ = 25 °C, IAS = 1.20 Amps, L = 11.10 mH
Current decaying linearly to zero in 1 μsec
Frequency limited by TJ max. VA = 1.5 x VR typical
Electrical Specifications
Parameters
VFM
32CTQ Units Conditions
Max. Forward Voltage Drop
(1)
* See Fig. 1
IRM
Max. Reverse Leakage Current (1)
0.49
V
@ 15A
0.58
V
@ 30A
0.40
V
@ 15A
0.53
V
@ 30A
1.75
mA
TJ = 25 °C
* See Fig. 2
97
mA
TJ = 125 °C
VF(TO) Threshold Voltage
0.233
V
TJ = TJ max.
TJ = 25 °C
TJ = 125 °C
VR = rated VR
rt
Forward Slope Resistance
9.09
mΩ
CT
Max. Junction Capacitance Per Leg
1300
pF
VR = 5VDC, (test signal range 100Khz to 1Mhz) 25 °C
LS
Typical Series Inductance
8.0
nH
Measured lead to lead 5mm from package body
10,000
V/ μs
Per Leg
dv/dt Max. Voltage Rate of Change
(Rated VR )
(1) Pulse Width < 300μs, Duty Cycle < 2%
Thermal-Mechanical Specifications
Parameters
32CTQ Units Conditions
TJ
Max. Junction Temperature Range
- 55 to 150
°C
Tstg
Max. Storage Temperature Range
- 55 to 150
°C
RthJC Max. Thermal Resistance Junction
to Case
Per Leg
3.25
°C/W
DC operation
RthCS Typical Thermal Resistance,
0.50
°C/W
Mounting surface , smooth and greased
2 (0.07)
g (oz.)
Min.
6 (5)
Max.
12 (10)
Kg-cm
(Ibf-in)
* See Fig. 4
Case to Heatsink
wt
Approximate Weight
T
Mounting Torque
Marking Device
2
32CTQ030
www.irf.com
32CTQ..., 32CTQ...S, 32CTQ...-1
Bulletin PD-20265 rev. B 07/06
Reverse Current - I R (mA)
1000
100
TJ = 150°C
100
125°C
10
100°C
1
75°C
50°C
0.1
25°C
0.01
0.001
0
5
10
15
20
25
30
Reverse Voltage - VR (V)
Fig. 2 - Typical Values of Reverse Current
Vs. Reverse Voltage
10000
Junction Capacitance - C T (pF)
Instantaneous Forward Current - I F (A)
1000
10
TJ= 150°C
TJ= 125°C
TJ= 25°C
1
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
TJ = 25°C
1000
100
0
5
10
15
20
25
30
35
Reverse Voltage - VR (V)
Forward Voltage Drop - V FM (V)
Fig. 1 - Maximum Forward Voltage Drop Characteristics
Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage
Thermal Impedanc e Z thJC (°C/W)
10
1
D = 0.75
D = 0.50
D = 0.33
D = 0.25
D = 0.20
PDM
0.1
t1
0.01
Notes:
Single Pulse
(Thermal Resistanc e)
t2
1. Duty factor D = t 1 / t 2
2. Peak TJ = PDM x Z thJC+ TC
0.001
0.00001
0.0001
0.001
0.01
0.1
1
10
t 1 , Rec tangular Pulse Dura tion (Sec onds)
Fig. 4 - Maximum Thermal Impedance Z thJC Characteristics
www.irf.com
3
32CTQ..., 32CTQ...S, 32CTQ...-1
Bulletin PD-20265 rev. B 07/06
10
150
Average Power Loss - (Watts)
Allowable Case Temperature - (°C)
160
140
DC
130
120
Sq uare wa ve (D = 0.50)
80% Rated V R a pplied
110
100
D = 0.20
D = 0.25
D = 0.33
D = 0.50
D = 0.75
8
RMSLimit
6
DC
4
2
90
see note (2)
0
80
0
5
10
15
20
0
25
Average Forward Current - I F(AV) (A)
Fig. 5 - Maximum Allowable Case Temperature
Vs. Average Forward Current
Non-Repetitive Surge Current - I FSM (A)
5
10
15
20
25
Average Forward Current - I F(AV) (A)
Fig. 6 - Forward Power Loss Characteristics
1000
At Any Rated Load Condition
And With Rated VRRM Applied
Following Surge
100
10
100
1000
10000
Square Wave Pulse Duration - t p (microsec)
Fig. 7 - Maximum Non-Repetitive Surge Current
L
IRFP460
DUT
Rg = 25 ohm
CURRENT
MONITOR
HIGH-SPEED
SWITCH
FREE-WHEEL
DIODE
+
Vd = 25 Volt
40HFL40S02
Fig. 8 - Unclamped Inductive Test Circuit
(2) Formula used: TC = TJ - (Pd + PdREV) x R thJC ;
Pd = Forward Power Loss = I F(AV) x VFM @ (I F(AV) / D) (see Fig. 6);
Pd REV = Inverse Power Loss = VR1 x IR (1 - D); I R @ VR1 = 80% rated VR
4
www.irf.com
32CTQ..., 32CTQ...S, 32CTQ...-1
Bulletin PD-20265 rev. B 07/06
Outline Table
Conform to JEDEC outline TO-220AB
Conform to JEDEC outline D2Pak (SMD-220)
Dimensions in millimeters and (inches)
www.irf.com
5
32CTQ..., 32CTQ...S, 32CTQ...-1
Bulletin PD-20265 rev. B 07/06
Outline Table
Modified JEDEC outline TO-262
Dimensions in millimeters and (inches)
Tape & Reel Information
Dimensions in millimeters and (inches)
6
www.irf.com
32CTQ..., 32CTQ...S, 32CTQ...-1
Bulletin PD-20265 rev. B 07/06
Part Marking Information
TO-220
EXAMPLE: THIS IS A 32CTQ030
LOT CODE 1789
ASSEMBLED ON WW 19, 2000
IN THE ASSEMBLY LINE "C"
PART NUMBER
INTERNATIONAL
RECTIFIER
LOGO
DATE CODE
YEAR 0 = 2000
WEEK 19
LINE C
ASSEMBLY
LOT CODE
D2PAK
INTERNATIONAL
THIS IS A 32CTQ030S
RECTIFIER
LOT CODE 8024
LOGO
ASSEMBLED ON WW 02, 2003
IN ASSEMBLY LINE "C"
ASSEMBLY
LOT CODE
PART NUMBER
32CTQ030S
DATE CODE
YEAR 3 = 2003
WEEK 02
LINE C
TO-262
INTERNATIONAL
EXAMPLE: THIS IS A 32CTQ030-1
RECTIFIER
LOT CODE 1789
LOGO
ASSEMBLED ON WW 19, 2002
IN ASSEMBLY LINE "C"
ASSEMBLY
LOT CODE
www.irf.com
PART NUMBER
DATE CODE
YEAR 2 = 2002
WEEK 19
LINE C
7
32CTQ..., 32CTQ...S, 32CTQ...-1
Bulletin PD-20265 rev. B 07/06
Ordering Information Table
Device Code
32
C
T
Q
030
S
TRL
-
1
2
3
4
5
6
7
8
1
-
Current Rating (30A)
2
-
Circuit Configuration
C = Common Cathode
3
-
T = TO-220
4
-
Schottky "Q" Series
025 = 25V
5
-
Voltage Ratings
030 = 30V
6
-
y S = D2Pak
7
-
y -1= TO-262
y none = Tube (50 pieces)
y TRL = Tape & Reel (Left Oriented - for D 2Pak only)
y TRR = Tape & Reel (Right Oriented - for D 2Pak only)
8
-
y none = Standard Production
y PbF = Lead-Free
Data and specifications subject to change without notice.
This product has been designed and qualified for Industrial Level.
Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 07/06
8
www.irf.com