INFINEON SCD5584

SCD5580
YELLOW SCD5581
HIGH EFFICIENCY RED SCD5582
GREEN SCD5583
HIGH EFFICIENCY GREEN SCD5584
STANDARD RED
Slimline
.145” 8-Character 5x5 Dot Matrix
Serial Input Dot Addressable Intelligent Display
Package Dimensions in inches (mm)
1.500 max. (38.10)
.187
.100
(.47)
(2.54)
0.145
(3.68)
.050
(1.27)
typ.
.394 –.006
(10.0 –.15)
Pin 1
Indicator
0.160 –.02
(4.06 –.51)
FEATURES
• Eight 0.145" (3.68 mm) 5x5 dot matrix characters in red, yellow, high efficiency red,
green, or high efficiency green
• Optimum display surface efficiency
(display area to package ratio)
• Low power–30% less power dissipation
than 5x7 format
• High speed data input rate: 5 MHz
• ROMless serial input, dot addressable display–ideal for user defined characters
• Built-in decoders, multiplexers and LED
drivers
• Readable from 6 feet (1.8 meters)
• Wide viewing angle, X axis ± 55°, Y axis ± 65°
• Attributes
– 200 bit RAM for user defined characters
– Eight dimming levels
– Power down mode (<250 mW)
– Hardware/software clear function
– Lamp test
• Internal or external clock
• End-stackable dual-in-line plastic package
• 3.3 V capability
1.
2.
3.
4.
.012 (.30)
typ.
.300 –.020
(7.62 –.51) 1
0.200
(5.08)
EIA date code
Intensity Code
SCD-558X
Hue Category
Z
Y
SIEMENS YYWW
Seating Plane
.020 (.51) typ.
.100 –.010 typ.
(2.54 –.25)
Tol. non-cum. 1
1.300 ref.
(33.02)
1.312 ref.
(33.32)
Dimension is at Seating Plane
Display matrix and pins centered on package outline.
Display matrix centered to pin array.
Tolerance: .XXX = ± .010 (.25)
DESCRIPTION
The SCD5580 (Red), SCD5581 (Yellow), SCD5582 (HER), SCD5583
(Green) and SCD5584 (HEG) are eight digit dot addressable 5x5 matrix,
Serial Input, Intelligent Displays.
The eight 0.145" (3.68 mm) high digits are packaged in a rugged, high
quality optically transparent, standard 0.3" pin spacing 28 pin plastic
DIP.
The on-board CMOS has a 200 bit RAM, one bit associated with one
LED, each to generate User Defined Characters. Due to the reduced
LED count, power requirement and heat dissipation are reduced by
30%. Additionally in Power Down Mode quiescent current is <50 µA.
The SCD558X is designed to work with the Serial port of most common
microprocessors. The multiplex Clock I/O (CLK I/O) and multiplex Clock
Select (CLK SEL) pins offer the user the capability to supply a high
speed external multiplex clock. This feature can minimize audio in-band
interference for portable communication equipment or eliminate the
visual synchronization effects found in high vibration environments such
as avionic equipment
2–1
Maximum Ratings
DC Supply Voltage ......................................................... –0.5 to +7.0 Vdc
Input Voltage Levels Relative
to Ground.................................................................–0.5 toVCC+0.5 Vdc
Operating Temperature .................................................. –40°C to +85°C
Storage Temperature ..................................................... –40°C to +100°C
Maximum Solder Temperature 0.063"
below Seating Plane, t<5 sec........................................................260°C
Relative Humidity at 85°C.................................................................. 85%
Maximum Number of LEDs on at 100% Brightness ............................128
Maximum Power Dissipation ......................................................1.7 Watts
IC Junction Temperature .................................................................125°C
ESD (100 pF, 1.5 KΩ)......................................................................... 2 KV
Maximum Input Current ............................................................. ± 100 mA.
Figure 1a. Data write cycle
3.5 V
LOAD
1.5 V
TLDS
TLDH
3.5 V
DATA
1.5 V
Switching Specifications (over operating
temperature range and VCC=4.5 V to 5.5 V)
Symbol
Description
Min.
Units
TRC
Reset Active Time
600
ns
TLDS
Load SetupTime
50
ns
TDS
Data Setup Time
50
ns
TSDCLK
Clock Period
200
ns
TSDCW
Clock Width
70
ns
TLDH
Load Hold Time
0
ns
TDH
Data Hold Time
25
ns
TWR
Total Write Time
2.2
µs
TBL
Time Between Loads
600
ns
Note: TSDCW is the minimum time the SDCLK may be
low or high. The SDCLK period must be a minimum of 200 ns.
TDS
TDH
3.5 V
SDCLK
1.5 V
TSDCW
TSDCW
TSDCLK Period
Figure 1b. Instruction cycle
TWR
TBL
LOAD
SDCLK
DATA
D0
D1
D2
D3
D4
D5
D6
D7
D0
D4
D5
D6
D7
D0
OR
LOAD
SDCLK
DATA
D0
D1
D2
D3
PD – Maximum Power Dissipation – Watts
Figure 2. Maximum power dissipation vs. temperature
3.0
2.5
2.0
θJA=31°C/W
1.5
1.0
0.5
0.0
–40 –30 –20 –10
0
10
20
30
40
50
60
70
80
90 100 120 130 140
TA – °C Ambient Temperature
SCD5580/5581/5582/5583/5584
2–2
Electrical Characteristics (over Operating Temperature)
Parameter
Min.
Typ.
Max.
Units
VCC
4.5
5.0
5.5
V
50
µA
VCC=5 V, all inputs=0 V or VCC
290
mA
VCC=5 V, “#” displayed in all 8 digits at 100%
brightness at 25°C
IIL Input Current
–10
µA
VCC=5 V, VIN=0 V (all inputs)
IIH Input Current
+10
µA
VCC=VIN=5.0 V (all inputs)
V
VCC=4.5 to 5 V
V
VCC=4.5 to 5 V
ICC (Power Down Mode) (4)
ICC 8 digits, 16 dots/character
VIH
200
3.5
VIL
1.5
Condition
IOH (Clk I/O)
–8.9
mA
VCC=4.5 V, VOH=2.4 V
IOL (Clk I/O)
1.6
mA
VCC=4.5 V, VOH=0.4 V
θJC-PIN
31
°C/W
Fext External Clock Input Frequency
120
347
KHz
VCC=5 V, CLKSEL=0
FOSC Internal Clock Input Frequency
120
347
KHz
VCC=5 V, CLKSEL=1
Clock I/O Bus Loading
240
pF
Clock Out Rise Time
500
ns
VCC=4.5 V, VOH=2.4 V
Clock Out Fall Time
500
ns
VCC=4.5 V, VOH=2.4 V
1086
Hz
FM, Digit
375
768
Notes:
1. Peak current=5⁄3 X ICC.
2. Unused inputs must be tied high.
3. Contact Siemens for 3.3 volt operation.
4. External oscillator must be stopped if being used to maintain an ICC<50 µ
Input/Output Circuits
Figures 3 and 4 show the input and output resistor/diode networks used
for ESD protection and to eliminate substrate latch-up caused by input
voltage over/under shoot.A.
Figure 3. Inputs
Figure 4. Clock I/O
VCC
VCC
input
input/output
1 KΩ
1 KΩ
GND
GND
SCD5580/5581/5582/5583/5584
2–3
Optical Characteristics at 25°C
VCC=5.0 V at 100% Brightness Level, Viewing Angle: X Axis ± 55°, Y Axis ± 65°
Red SCD5580
Description
Symbol
Min.
Typ.
Units
Luminous Intensity
IV
36
90
µcd/dot
Peak Wavelength
λPEAK
665
nm
Dominant Wavelength
λD
639
nm
Yellow SCD5581
Description
Symbol
Min.
Typ.
Units
Luminous Intensity
IV
124
213
µcd/dot
Peak Wavelength
λPEAK
583
nm
Dominant Wavelength
λD
584
nm
High Efficiency Red SCD5582
Description
Symbol
Min.
Typ.
Units
Luminous Intensity
IV
124
265
µcd/dot
Peak Wavelength
λPEAK
630
nm
Dominant Wavelength
λD
626
nm
Green SCD5583
Description
Symbol
Min.
Typ.
Units
Luminous Intensity
IV
124
221
µcd/dot
Peak Wavelength
λPEAK
565
nm
Dominant Wavelength
λD
569
nm
High Efficiency Green SCD5584
Description
Symbol
Min.
Typ.
Units
Luminous Intensity
IV
124
505
µcd/dot
Peak Wavelength
λPEAK
568
nm
Dominant Wavelength
λD
572
nm
Notes:
1. Dot to dot intensity matching at 100% brightness is 1.8:1.
2. Displays are binned for hue at 2 nm intervals.
3. Displays within a given intensity category have an intensity matching of 1.5:1 (max.).
SCD5580/5581/5582/5583/5584
2–4
Figure 5. Top view
Pin Definitions
28
15
1
Character 0
14
Character 7
Pin Assignments
Pin
Function
Definition
1
SDCLK
Loads data into the 8-bit serial data register on a low
to high transition.
2
LOAD
Low input enables data clocking into 8-bit serial shift
register. When LOAD goes high, the contents of 8-bit
serial Shift Register will be decoded.
3
NC
No connection
4
NC
No connection
5
NC
No connection
6
VCC
Power supply/heat sink
7
NP
No pin
Pin
Function
Pin
Function
1
SDCLK
28
GND
8
NP
No pin
2
LOAD
27
DATA
9
VCC
Power supply/heat sink
3
NC
26
NC
10
NC
No connection
4
NC
25
NC
11
NC
No connection
5
NC
24
NC
12
NC
No connection
6
VCC
23
VCC
7
NP
22
NP
13
RST
8
NP
21
NP
Asynchronous input, when low will clear the Multiplex Counter, User RAM and Data Register. Control
Word Register is set to 100% brightness and the
Address Register is set to select Digit 0. The display
is blanked.
9
VCC
20
VCC
14
GND
Power supply ground
10
NC
19
VCC
11
NC
18
NC
15
CLK I/O
Outputs master clock or inputs
external clock.
12
NC
17
NC
16
CLKSEL
H=internal clock, L=external clock
13
RST
16
CLKSEL
17
NC
No connection
14
GND
15
CLK I/O
18
NC
No connection
19
VCC
Power supply/heat sink
20
VCC
Power supply/heat sink
21
NP
No pin
22
NP
No pin
23
VCC
Power supply/heat sink
24
NC
No connection
25
NC
No connection
26
NC
No connection
27
DATA
Serial data input
28
GND
Power supply ground
Figure 6. Display column and row format
Row 1
Row 2
Row 3
Row 4
C
0
1
0
0
0
C
1
1
0
0
0
C
2
1
1
1
1
C
3
1
0
0
0
C
4
1
0
0
0
1=Display Dot “on”
2=Display Dot “off”
Column Data Ranges
Row 0
00H to 1FH
Row 1
20H to 3FH
R0w 2
40H to 5FH
Row 3
60H to 7FH
Row 4
80H to 9FH
Figure 7. Dot matrix format
0.033
(0.84)
typ.
0.100
(2.54)
C0 C1 C2 C3 C4
R0
R1
R2
0.145
(3.68)
R3
0.011
(0.28)
typ.
R4
0.022
(0.56) typ.
Dimensions in inches (mm)
TOLERANCE: .XXX=±.010 (.25)
SCD5580/5581/5582/5583/5584
2–5
Operation of the SCD558X
The SCD558X requires only 4 lines as compared to 15 for an
equivalent 8 character parallel input part.
The SCD558X display consists of a CMOS IC containing control logic and drivers for eight 5x5 characters. These components are assembled in a compact (38 mm x 10 mm) plastic
package.
The on-board CMOS IC is the electronic heart of the display.
The IC accepts decoded serial data, which is stored in the
internal RAM . Asynchronously the RAM is read by the character multiplexer at a strobe rate that results in a flicker free
display. Figure 8 shows the three functional areas of the IC.
These include: the input serial data register and control
logic, a 200 bits two port RAM, and an internal multiplexer/
display driver.
Individual LED dot addressablity allows the user great freedom in creating special characters or mini-icons. The User
Definable Character Set Examples illustrate 200 different
character and symbol possibilities.
The use of a serial data interface provides a highly efficient
interconnection between the display and the mother board.
Figure 8. SCD558X block diagram
8 - 5X5 Characters
10
0
—
Row Decoder
& Driver
1
2
3
4
5
6
7
— 20
Column Logic & Driver
Mux CLK I/O
Mux Clock SEL
Counter Chain
& Timing Logic
Brightness &
Lamp Test
RESET
Oscillator
Power Down
Display
Multiplexer
Serial Data
—3
—5
OPCODE
Decode
Character
Address
Register
Control
Word
Address
Register
5
—
Load
5
D4 D3 D2 D1 D0
DATA
—
D7 D6 D5
OPCODE
WRITE
Character/
Row
Address
Decode
RAM
200 Bits
WRITE 40 X 5
READ 10 X 20
Column
Output
4
—
Serial Data
Clock
Software
Clear
SCD5580/5581/5582/5583/5584
2–6
Row Address Register bits, D7–D5 (Table 3), direct the Column Data bits, D4–D0 (Table 3) to specific RAM location.
Table 1 shows the Row Address for the example character
“D.” Column data is written and read asynchronously from the
200 bit RAM. Once loaded the internal oscillator and character multiplexer reads the data from the RAM. These characters are row strobed with column data as shown in Figures 8
and 9. The character strobe rate is determined by the internal
or user supplied external MUX Clock and the IC’s ÷ 320
counter.
The following explains how to format the serial data to be
loaded into the display. The user supplies a string of bit
mapped decoded characters. The contents of this string is
shown in Figure 9a. Figure 9b shows that each character
consist of six 8 bit words. The first word encodes the display
character location and the succeeding five bytes are row
data. The row data represents the status (On, Off) of individual column LEDs. Figure 9c shows that each that each 8 bit
word is formatted to include a three bit Operational Code
(OPCODE) defined by bits D7–D5 and five bits (D4–D0) representing Column Data, Character Address, or Control Word
Data.
Table 1. Character “D”
Figure 9d shows the sequence for loading the bytes of data.
Bringing the LOAD line low enables the serial register to
accept data. The shift action occurs on the low to high transition of the serial data clock (SDCLK). The least significant bit
(D0) is loaded first. After eight clock pulses the LOAD line is
brought high. With this transition the OPCODE is decoded.
The decoded OPCODE directs D4-D0 to be latched in the
Character Address register, stored in the RAM as Column
data, or latched in the Control Word register. The control IC
requires a minimum 600 ns delay between successive byte
loads. As indicated in Figure 9a, a total of 528 bits of data
are required to load all eight characters into the display.
Opcode
Column Data
HEX
D7
D6
D5
D4
D3
D2
D1
D0
Row 0
0
0
0
1
1
1
1
0
1E
Row 1
0
0
1
1
0
0
0
1
31
Row 2
0
1
0
1
0
0
0
1
51
Row 3
0
1
1
1
0
0
0
1
71
Row 4
1
0
0
1
1
1
1
0
9E
Figure 9a–d. Loading serial character data
Example: Serial Clock = 5 MHz, Clock Period = 200 ns
528 Clock Cycles, 105.6 µs
a.
Character 0
Character 1
Character 2
Character 3
Character 4
Character 5
Character 6
Character 7
66 Clock Cycles, 13.2 µs
b.
Character 0
Address
Row 0 Column
Data
Row 1 Column
Data
Row 2 Column
Data
Row 4 Column
Data
11 Clock Cycles, 2.2 µs
11 Clock Cycles, 2.2 µs
c.
Row 3 Column
Data
Column Data
Character Address
Time
OPCODE
Time
OPCODE
Between
D0 D1 D2 D3 D4 D5 D6 D7 Between
D0
D1
D2
D3
D4
D5 D6 D7
Loads
Loads
0 0
0
0
0
1
0
0 600 ns(min.) C4 C3 C2 C1 C0
600 ns(min.)
LOAD
Serial
Clock
d.
Clock
Period
DATA
D0
D1
D2
D3
D4
D5
D6
D7
Time between LOADS
t0
SCD5580/5581/5582/5583/5584
2–7
The user can activate four Control functions. These include:
LED Brightness Level, Lamp Test, IC Power Down, or Display
Clear. OPCODEs and five bit words are used to initiate these
functions. The OPCODEs and Control Words for the Character Address and Loading Column Data are shown in Tables 2
and 3.
The user can select seven specific LED brightness levels,
Table 4. These brightness levels (in percentages of full brightness of the display) include: 100% (F0HEX), 53% (F1HEX),
40% (F2HEX ), 27% (F3HEX ), 20% (F4HEX ), 13% (F5HEX), and
6.6% (F6HEX ). The brightness levels are controlled by changing the duty factor of the row strobe pulse.
Table 2. Load character address
Table 4. Display brightness
Opcode
Character Address
Opcode
Operation
Load
D7 D6 D5 D4 D3 D2 D1 D0
Control Word
D7
D6
D5
D4
D3
D2
D1
D0
Hex
Operation
Level
1
0
1
0
0
0
0
0
A0
Character 0
1
1
1
1
0
0
0
0
F0
100%
1
0
1
0
0
0
0
1
A1
Character 1
1
1
1
1
0
0
0
1
F1
53%
1
0
1
0
0
0
1
0
A2
Character 2
1
1
1
1
0
0
1
0
F2
40%
1
0
1
0
0
0
1
1
A3
Character 3
1
1
1
1
0
0
1
1
F3
27%
1
0
1
0
0
1
0
0
A4
Character 4
1
1
1
1
0
1
0
0
A4
20%
1
0
1
0
0
1
0
1
A5
Character 5
1
1
1
1
0
1
0
1
F5
13%
1
0
1
0
0
1
1
0
A6
Character 6
1
1
1
1
0
1
1
0
F6
6.6%
1
0
1
0
0
1
1
1
A7
Character 7
The SCD558X offers a unique Display Power Down feature
which reduces ICC to less than 50 µA. When FFHEX is loaded,
as shown in Table 5, the display is set to 0% brightness and
the internal multiplex clock is stopped. When in the Power
Down mode data may still be written into the RAM. The display is reactivated by loading a new Brightness Level Control
Word into the display.
Table 3. Load column data
Opcode
Column Data
Operation Load
D7
D6
D5
D4
D3
D2
D1
D0
0
0
0
C0
C1
C2
C3
C4
Row 0
0
0
1
C0
C1
C2
C3
C4
Row 1
0
1
0
C0
C1
C2
C3
C4
Row 2
0
1
1
C0
C1
C2
C3
C4
Row 3
1
0
0
C0
C1
C2
C3
C4
Row 4
Table 5. Power down
Opcode
Control Word
Hex Operation
D7
D6
D5
D4
D3
D2
D1
D0
1
1
1
1
1
1
1
1
FF
0%
brightness
Figure 10. Row and column location
Row 0
off LED
Row 1
on LED
Row 2
Previously “on” LED
The Lamp Test is enabled by loading F8HEX, Table 6, into the
serial shift register. This Control Word sets all of the LEDs to a
53% brightness level. Operation of the Lamp Test has no
affect on the RAM and is cleared by loading a Brightness
Control Word.
Row 3
Row 4
0 1 2 3 4
Columns
Figure 11. Row strobing
ROW LOAD
LOAD ROW 0
LOAD ROW 1
LOAD ROW 2
LOAD ROW 3
LOAD ROW 4
Row 0
Row 0
Row 0
Row 0
Row 0
Row 1
Row 1
Row 1
Row 1
Row 1
Row 2
Row 2
Row 2
Row 2
Row 2
Row 3
Row 3
Row 3
Row 3
Row 3
Row 4
Row 4
0 1 2 3 4
Columns
Row 4
0 1 2 3 4
Columns
Row 4
0 1 2 3 4
Columns
Row 4
0 1 2 3 4
Columns
0 1 2 3 4
Columns
SCD5580/5581/5582/5583/5584
2–8
perature of 85°C. Approximately 60% of this power is dissipated by the IC to the PC board via the VCC connection (pins
6, 9, 20, 23). Optimum thermal reliability is obtained by connecting all of the VCC pins to a common pad located on both
sides of the PC board. This technique offers a low thermal
resistance for IC to system ambient.
Table 6. Lamp test
Opcode
Control Word
Hex Operation
D7
D6
D5
D4
D3
D2
D1
D0
1
1
1
1
0
B
B
B
Lamp Test
(OFF)
0
Lamp Test
(ON)
1
1
1
1
1
0
0
F8
ESD Protection
The input protection structure of the SCD5580/1/2/3/4 provides significant protection against ESD damage. It is capable of withstanding discharges greater than 2 KV. Take all the
standard precautions, normal for CMOS components. These
include properly grounding personnel, tools, tables, and
transport carriers that come in contact with unshielded parts.
If these conditions are not, or cannot be met, keep the leads
of the device shorted together or the parts in anti-static packaging.
Table 7. Software clear
Opcode
Control Word
Hex Operation
D7
D6
D5
D4
D3
D2
D1
D0
1
1
0
0
0
0
0
0
C0
CLEAR
Soldering Considerations
Multiplexer and Display Driver
THE SCD5580/1/2/3/4 can be hand soldered with SN63 solder using a grounded iron set to 260°C.
The eight characters are row multiplexed with RAM resident
column data. The strobe rate is established by the internal or
external MUX Clock rate. The MUX Clock frequency is
divided by a 320 counter chain. This results in a typical
strobe rate of 750Hz. By pulling the Clock SEL line low, the
display can be operated from an external MUX Clock. The
external clock is attached to the CLK I/O connection (pin 15).
The maximum external MUX Clock frequency should be limited to 1 MHz.
Wave soldering is also possible following these conditions:
Preheat that does not exceed 93°C on the solder side of the
PC board or a package surface temperature of 85°C. Water
soluble organic acid flux (except carboxylic acid) or resinbased RMA flux without alcohol can be used.
Wave temperature of 245°C ± 5°C with a dwell between 1.5
sec. to 3.0 sec. Exposure to the wave should not exceed temperatures above 260°C for five seconds at 0.063" below the
seating plane. The packages should not be immersed in the
wave.
An asynchronous hardware Reset (pin 13) is also provided.
Bringing this pin low will clear the Character Address Register, Control Word Register, RAM, and blanks the display. This
action leaves the display set at Character Address 0, and the
Brightness Level set at 100%.
Post Solder Cleaning Procedures
The least offensive cleaning solution is hot D.I. water (60°C)
for less than 15 minutes. Addition of mild saponifiers is
acceptable. Do not use commercial dishwasher detergents.
Electrical & Mechanical Considerations
Interconnect Considerations
For faster cleaning, solvents may be used. Exercise care in
choosing solvents as some may chemically attack the nylon
package. Maximum exposure should not exceed two minutes
at elevated temperatures. Acceptable solvents are TF (trichorotrifluorethane), TA, 111 Trichloroethane, and unheated
acetone.(1)
Optimum product performance can be had when the following electrical and mechanical recommendations are
adopted. The SCD558X’s IC is constructed in a high speed
CMOS process, consequently high speed noise on the
SERIAL DATA, SERIAL DATA CLOCK, LOAD and RESET
lines may cause incorrect data to be written into the serial
shift register. Adhere to transmission line termination procedures when using fast line drivers and long cables (>10 cm).
Note: 1.Acceptable commercial solvents are: Basic TF, Arklone, P.
Genesolv, D. Genesolv DA, Blaco-Tron TF, Blaco-Tron TA,
and Freon TA.
Unacceptable solvents contain alcohol, methanol, methylene
chloride, ethanol, TP35, TCM, TMC, TMS+, TE, or TES. Since
many commercial mixtures exist, contact a solvent vendor
for chemical composition information. Some major solvent
manufacturers are: Allied Chemical Corporation, Specialty
Chemical Division, Morristown, NJ; Baron-Blakeslee, Chicago, IL; Dow Chemical, Midland, MI; E.I. DuPont de Nemours & Co., Wilmington, DE.
Good digital grounds (pins 14, 28) and power supply decoupling (pins 6, 9, 20, 23) will insure that ICC (<400 mA peak)
switching currents do not generate localized ground bounce.
Therefore it is recommended that each display package use
a 0.1 µF and 20 µF capacitor between VCC and ground.
When the internal MUX Clock is being used connect the
CLKSEL pin to VCC. In those applications where RESET
will not be connected to the system’s reset control, it is recommended that this pin be connected to the center node of
a series 0.1, µF and 100 KΩ RC network. Thus upon initial
power up the RESET will be held low for 10 ms allowing adequate time for the system power supply to stabilize.
For further information refer to Appnotes 18 and 19 in the current Siemens Optoelectronic Data Book.
An alternative to soldering and cleaning the display modules
is to use sockets. Naturally, 28 pin DIP sockets .300" wide
with .100" centers work well for single displays. Multiple display assemblies are best handled by longer SIP sockets or
DIP sockets when available for uniform package alignment.
The SCD558X allows up to 1.7 W of power dissipation at 70°
and 1.29 W power dissipation at a maximum operating tem-
SCD5580/5581/5582/5583/5584
2–9
Socket manufacturers are Aries Electronics, Inc., Frenchtown, NJ; Garry Manufacturing, New Brunswick, NJ; Robinson-Nugent, New Albany, IN; and Samtec Electronic
Hardward, New Albany, IN.
For further information refer to Appnote 22 in the current Siemens Optoelectronic Data Book.
Optical Considerations
The 0.145" high character of the SCD558X gives readability
up to eight feet. Proper filter selection enhances readability
over this distance.
Using filters emphasizes the contrast ratio between a lit LED
and the character background. This will increase the discrimination of different characters. The only limitation is cost.
Take into consideration the ambient lighting environment for
the best cost/benefit ratio for filters.
Incandescent (with almost no green) or fluorescent (with
almost no red) lights do not have the flat spectral response of
sunlight. Plastic band-pass filters are an inexpensive and
effective way to strengthen contrast ratios. The SCD5580/2
are red/high efficiency red displays and should be matched
with long wavelength pass filter in the 570 nm to 590 nm
range. The SCD5583/4 should be matched with a yellowgreen band-pass filter that peaks at 565 nm. For displays of
multiple colors, neutral density grey filters offer the best compromise.
Additional contrast enhancement is gained by shading the
displays. Plastic band-pass filters with built-in louvers offer
the next step up in contrast improvement. Plastic filters can
be improved further with anti-reflective coatings to reduce
glare. The trade-off is fuzzy characters. Mounting the filters
close to the display reduces this effect. Take care not to
overheat the plastic filter by allowing for proper air flow.
Optimal filter enhancements are gained by using circular
polarized, anti-reflective, band-pass filters. The circular polarizing further enhances contrast by reducing the light that
travels through the filter and reflects back off the display to
less than 1%.
Several filter manufacturers supply quality filter materials.
Some of them are: Panelgraphic Corporation, W. Caldwell,
NJ; SGL Homalite, Wilmington, DE; 3M Company, Visual
Products Division, St. Paul, MN; Polaroid Corporation, Polarizer Division, Cambridge, MA; Marks Polarized Corporation,
Deer Park, NY, Hoya Optics, Inc., Fremont, CA.
One last note on mounting filters: recessing displays and
bezel assemblies is an inexpensive way to provide a shading
effect in overhead lighting situations. Several Bezel manufacturers are: R.M.F. Products, Batavia, IL; Nobex Components,
Griffith Plastic Corp., Burlingame, CA; Photo Chemical Products of California, Santa Monica, CA; I.E.E.–Atlas, Van Nuys,
CA.
Microprocessor Interface
The microprocessor interface is through the serial port, SPI
port or one out of eight data bits on the eight bit parallel port
and also control lines SDCLK and LOAD.
Power Up Sequence
Upon power up display will come on at random. Thus the display should be reset at power-up. The reset will set the
Address Register to Digit 0, User RAM is set to 0 (display
blank) the Control Word is set to 0 (100% brightness with
Lamp Test off) and the internal counters are reset.
Figure 12. SCD Interface to Siemens/Intel 8031 Microprocessor (using serial port in mode 0)
VCC
28
VCC
27
DATA
VCC
40
XTAL2 RXD 10
TXD 11
20 19 16
15 28
SCD
MASTER
SD
CLK LOAD
1 2
18
23
6
9
13 14
27
DATA
23
15
SCD
SLAVE
SD
CLK LOAD
1 2
2019 16
6
9
13 14
+
22 µF
TAN
.01
µF
VCC
19 XTAL1
U1
8031
P3.7 17
9 RST
P3.3 13
P3.4 14
SCD5580/5581/5582/5583/5584
2–10
Figure 13. SCD558X Interface with Intel/Siemens 8031 Microprocessor (using one bit of parallel port as serial input)
VCC
28
27
DATA
1 2
6
40 P3.0 10
18 XTAL2 P3.1 11
P3.6 16
P0.0
20 19 16
15 28
SCD
MASTER
SD
CLK LOAD
VCC
19 XTAL1
23
9
27
DATA
23
1 2
+
SCD
SLAVE
SD
CLK LOAD
13 14
20 19 16 15
6
9
13 14
.01
µF
22 µF
TAN
VCC
39
U1
8031
VCC
1 RST
9 P1.0
20
Figure 14. SCD558X Interface with Motorola 68HC05C4 Microprocessor (using SPI Port)
VCC
28
27
DATA
23
1 2
38
40
OSC1
39 OSC2
PA0
PA1
SCLK
MOSI
11
10
33
32
15 28
SCD
MASTER
SD
CLK LOAD
VCC
20 19 16
6
9
13 14
VCC
27
DATA
23
15
+
SCD
SLAVE
SD
CLK LOAD
1 2
20 19 16
6
9
13 14
22 µF
Tan
.01
µF
U1
68HC05C4
VCC
1 RST
9 PA2
20
SCD5580/5581/5582/5583/5584
2–11
Cascading Multiple Displays
Multiple displays can be cascaded using the CLK SEL and CLK I/O pins as shown below. The display designated as the Master Clock source should have its CLK SEL pin tied high and the slaves should have their CLK SEL pins tied low. All CLK I/O
pins should be tied together. One display CLK I/O can drive 15 slave CLK I/Os. Use RST to synchronize all display counters.
Figure 15. Cascading multiple displays
RST
VCC
RST
CLK I/O
CLK SEL
Intelligent Display
DATA
SDCLK LOAD
14 more displays
in between
RST
CLK I/O
CLK SEL
Intelligent Display
DATA SDCLK
LOAD
DATA
SDCLK
A0
A1
A2
A3
0
Chip
Address
Decoder 15
LD
CE
Address Decode 1–14
Loading Data Into the Display
Use following procedure to load data into the display:
1.
Power up the display.
2.
Bring RST low (600 ns duration minimum) to clear the Multiplex Counter, Address Register, Control Word Register,
User Ram and Data Register. The display will be blank. Display brightness is set to 100%.
3.
If a different brightness is desired, load the proper brightness opcode into the Control Word Register.
4.
Load the Digit Address into the display.
5.
Load display row and column data for the selected digit.
6.
Repeat steps 4 and 5 for all digits.
Data contents for the word “Displays”
Step
D7
D6
D5
D4
D3
D2
D1
D0
Function
A
1
1
0
0
0
0
0
0
CLEAR
B (optional)
1
1
1
1
0
B
B
B
BRIGHTNESS SELECT
1
1
0
1
0
0
0
0
0
DIGIT D0 SELECT
2
0
0
0
1
1
1
1
0
ROW 0 D0 (D)
3
0
0
1
1
0
0
0
1
ROW 1 D0 (D)
4
0
1
0
1
0
0
0
1
ROW 2 D0 (D)
5
0
1
1
1
0
0
0
1
ROW 3 D0 (D)
6
1
0
0
1
1
1
1
0
ROW 4 D0 (D)
7
1
0
1
0
0
0
0
1
DIGIT D1 SELECT
8
0
0
0
0
1
1
1
0
ROW 0 D0 (I)
9
0
0
1
0
0
1
0
0
ROW 1 D0 (I)
10
0
1
0
0
0
1
0
0
ROW 2 D0 (I)
11
0
1
1
0
0
1
0
0
ROW 3 D0 (I)
12
1
0
0
0
1
1
1
0
ROW 4 D0 (I)
SCD5580/5581/5582/5583/5584
2–12
Data contents for the word “Displays” (continued)
Step
D7
D6
D5
D4
D3
D2
D1
D0
Function
13
1
0
1
0
0
0
1
0
DIGIT D2 SELECT
14
0
0
0
0
1
1
1
1
ROW 0 D2 (S)
15
0
0
1
1
0
0
0
0
ROW 1 D2 (S)
16
0
1
0
0
1
1
1
0
ROW 2 D2 (S)
17
0
1
1
0
0
0
0
1
ROW 3 D2 (S)
18
1
0
0
1
1
1
1
0
ROW 4 D2 (S)
19
1
0
1
0
0
0
1
1
DIGIT D3 SELECT
20
0
0
0
1
1
1
1
0
ROW 0 D3 (P)
21
0
0
1
1
0
0
0
1
ROW 1 D3 (P)
22
0
1
0
1
1
1
1
0
ROW 2 D3 (P)
23
0
1
1
1
0
0
0
0
ROW 3 D3 (P)
24
1
0
0
1
0
0
0
0
ROW 4 D3 (P)
25
1
0
1
0
0
1
0
0
DIGIT D4 SELECT
26
0
0
0
1
0
0
0
0
ROW 0 D4 (L)
27
0
0
1
1
0
0
0
0
ROW 1 D4 (L)
28
0
1
0
1
0
0
0
0
ROW 2 D4 (L)
29
0
1
1
1
0
0
0
0
ROW 3 D4 (L)
30
1
0
0
1
1
1
1
1
ROW 4 D4 (L)
31
1
0
1
0
0
1
0
1
DIGIT D5 SELECT
32
0
0
0
0
0
1
0
0
ROW 0 D5 (A)
33
0
0
1
0
1
0
1
0
ROW 1 D5 (A)
34
0
1
0
1
1
1
1
1
ROW 2 D5 (A)
35
0
1
1
1
0
0
0
1
ROW 3 D5 (A)
36
1
0
0
1
0
0
0
1
ROW 4 D5 (A)
37
1
0
1
0
0
1
1
0
DIGIT D6 SELECT
38
0
0
0
1
0
0
0
1
ROW 0 D6 (Y)
39
0
0
1
0
1
0
1
0
ROW 1 D6 (Y)
40
0
1
0
0
0
1
0
0
ROW 2 D6 (Y)
41
0
1
1
0
0
1
0
0
ROW 3 D6 (Y)
42
1
0
0
0
0
1
0
0
ROW 4 D6 (Y)
43
1
0
1
0
0
1
1
1
DIGIT D7 SELECT
44
0
0
0
0
1
1
1
1
ROW 0 D7 (S)
45
0
0
1
1
0
0
0
0
ROW 1 D7 (S)
46
0
1
0
0
1
1
1
0
ROW 2 D7 (S)
47
0
1
1
0
0
0
0
1
ROW 3 D7 (S)
48
1
0
0
1
1
1
1
0
ROW 4 D7 (S)
Note: If the display is already reset at Power Up, there is no need for Software Clear.
SCD5580/5581/5582/5583/5584
2–13
User Definable Character Set Examples*
Upper and Lower Case Alphabets
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
04
2A
5F
71
91
1E
29
4E
69
9E
0F
30
50
70
8F
1E
29
49
69
9E
1F
30
5E
70
9F
1F
30
5E
70
90
0F
30
53
71
8F
11
31
5F
71
91
0E
24
44
64
8E
01
21
41
71
8E
13
34
58
74
93
10
30
50
70
9F
11
3B
55
71
91
11
39
55
73
91
0E
31
51
71
8E
1E
31
5E
70
90
0C
32
56
72
8D
1E
31
5E
74
92
0F
30
4E
61
9E
1F
24
44
64
84
11
31
51
71
8E
11
31
51
6A
84
11
31
55
7B
91
11
2A
44
6A
91
11
2A
44
64
84
1F
22
44
68
9F
00
2E
52
72
8D
10
30
5E
71
9E
00
2F
50
70
8F
01
21
4F
71
8F
00
2E
5F
70
8E
04
2A
48
7C
88
00
2F
50
73
8F
10
30
56
79
91
04
20
4C
64
8E
00
26
42
72
8C
10
30
56
78
96
0C
24
44
64
8E
00
2A
55
71
91
00
36
59
71
91
00
2E
51
71
8E
00
3E
51
7E
90
00
2F
51
6F
81
00
33
54
78
90
00
23
44
62
8C
08
3C
48
6A
84
00
32
52
72
8D
00
31
51
6A
84
00
31
55
7B
91
00
32
4C
6C
92
00
31
4A
64
98
00
3E
44
68
9E
DOT ON = 1
DOT OFF = 0
Numerals and Punctuation
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
0E
33
55
79
8E
04
2C
44
64
8E
1E
21
46
68
9F
1E
21
4E
61
9E
06
2A
5F
62
82
1F
30
5E
61
9E
06
28
5E
71
8E
1F
22
44
68
88
0E
31
4E
71
8E
0E
31
4F
62
8C
0A
3F
4A
7F
8A
0F
34
4E
65
9E
06
29
5C
68
9F
19
3A
44
6B
93
08
34
4D
72
8D
0C
2C
44
68
80
02
24
44
64
82
08
24
44
64
88
0C
2C
48
64
80
04
24
5F
64
84
00
2C
4C
64
88
00
20
5F
60
80
00
20
40
6C
8C
01
22
44
68
90
04
24
44
60
84
0A
2A
40
60
80
07
24
44
64
87
10
28
44
62
81
1C
24
44
64
9C
0E
35
57
70
8E
00
20
40
60
9F
0C
2C
40
6C
8C
0C
20
4C
64
88
02
24
48
64
82
00
3F
40
7F
80
08
24
42
64
88
0E
31
42
64
88
06
24
48
64
86
0C
24
42
64
8C
04
24
40
64
84
11
2A
44
6E
84
15
2E
5F
6E
95
04
2A
51
60
80
08
35
42
60
80
DOT ON = 1
DOT OFF = 0
SCD5580/5581/5582/5583/5584
2–14
User Definable Character Set Examples* (continued)
Scientific Notations, etc.
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
06
2E
5E
6E
86
04
24
48
71
8E
1F
20
59
75
93
1F
20
56
79
91
0E
20
4A
64
8A
0D
32
52
72
8D
0C
32
56
71
96
0E
24
4E
71
8E
00
24
4A
71
9F
10
3C
52
72
81
0E
31
5F
71
8E
10
28
44
6A
91
09
29
49
6E
90
01
2E
54
64
84
04
2E
55
6E
84
0E
31
51
6A
9B
01
2E
5A
6A
8A
0F
32
52
72
8C
1F
28
44
68
9F
18
24
48
7C
80
1C
28
44
78
80
12
36
5A
67
80
06
21
5A
67
80
07
22
59
66
80
1C
34
5C
60
80
0F
28
48
78
88
04
2E
5F
6E
80
00
24
4E
7F
8E
00
2E
5F
6E
84
0E
3F
4E
64
80
04
3E
5F
7E
84
04
2F
5F
6F
84
0E
2E
4E
6E
8E
00
3F
5F
7F
80
04
2E
55
64
84
04
24
55
6E
84
04
22
5F
62
84
04
28
5F
68
84
1F
31
51
71
9F
08
2C
4A
78
98
0A
35
4A
75
8A
15
2A
55
6A
95
1F
35
5F
75
9F
00
3F
5F
7C
80
0E
3F
5B
7F
8E
00
27
4F
78
9C
00
3C
5F
63
87
00
20
40
60
83
00
20
40
67
9F
00
23
5F
7F
9F
0C
3C
5C
7C
9C
15
2E
44
64
84
DOT ON = 1
DOT OFF = 0
Foreign Characters
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
HEX
CODE
1F
21
5F
62
84
1F
21
46
64
88
01
22
46
6A
82
04
3F
51
61
86
00
3F
44
64
9F
02
3F
46
6A
92
08
3F
49
6A
88
1F
21
45
67
8C
02
3F
51
62
8C
08
3F
49
69
92
04
3F
44
7F
84
0F
29
51
62
8C
08
2F
52
62
82
0F
21
41
61
9F
0A
3F
4A
62
8C
19
21
59
62
9C
0F
29
55
63
8C
01
3E
42
7F
86
15
35
55
62
8C
0E
20
5F
64
98
08
28
4C
6A
88
04
3F
44
64
98
0E
20
40
60
9F
1F
21
4A
64
9A
04
3E
44
6E
95
04
24
44
68
90
04
22
51
71
91
10
3F
50
70
8F
1F
21
41
62
8C
0E
20
4E
60
8F
04
28
51
7F
81
01
21
4A
64
8A
1F
28
5F
68
87
1E
22
42
62
9F
1F
21
5F
61
9F
0E
20
5F
61
8E
12
32
52
64
88
04
34
54
75
96
1E
25
4F
74
8F
0F
34
5F
74
97
0F
30
4F
64
98
0F
33
55
79
9E
0F
34
57
74
8F
00
2A
5F
74
8B
08
24
4E
72
8F
0A
2E
51
7F
91
02
24
4C
64
8E
04
2A
4E
71
8E
0A
34
52
7A
96
08
24
51
71
8E
02
24
51
71
8E
04
2A
51
71
8E
DOT ON = 1
DOT OFF = 0
*CAUTION: No more than 128 LEDs “on” at one time at 100% brightness.
SCD5580/5581/5582/5583/5584